• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 48
  • 29
  • 6
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 106
  • 106
  • 52
  • 50
  • 42
  • 34
  • 33
  • 11
  • 10
  • 10
  • 10
  • 8
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Efeito do envelhecimento hidrotérmico na resistência flexural, rugosidade, módulo de Weibull e microestrutura da zircônia monolítica submetida a desgastes e métodos de acabamento de superfície /

Hatanaka, Gabriel Rodrigues. January 2018 (has links)
Orientador: Gelson Luis Adabo / Resumo: Desgastes para ajustes clínicos são necessários para adequada adaptação de próteses em zircônia, mas ainda não há um protocolo estabelecido. Este estudo avaliou o efeito de desgaste e polimento sobre a resistência à flexão (RF) e módulo de Weibull, rugosidade (Ra) e transformação de fase por microscopia eletrônica de varredura (MEV) de duas zircônias monolíticas (Prettau e Prettau Anterior) submetidas à degradação hidrotérmica (LTD). Foram obtidos corpos-de-prova com 20 x 4,0 x 1,2 mm, sem desgaste e com glaze (grupo controle) ou com 20 x 4,0 x 1,5 mm, os quais foram desgastados com fresa diamantada de granulação grossa (90-120 μm) em alta rotação sob irrigação. Após desgaste de 0,3 mm, foram realizados os protocolos de acabamento: sem polimento (D); polimento com borracha diamantada (DP); aplicação de glaze (DG); polimento com borracha diamantada + glaze (DPG). Metade dos corpos-de-prova foi envelhecida hidrotermicamente (EH) em autoclave (134 °C, 2 bars, 20 horas). Os dados de RF e Ra (n=30) foram analisados por teste de Kruskal-Wallis, testes complementares de Dunn e Student-Newman-Keuls, respectivamente (α=0,05). Nos grupos não envelhecidos, o material Prettau apresentou a seguinte ordem de resistência: D = DP > DPG > DG = C, e o Prettau Anterior: D = DP = C > DG = DPG. Após EH, para Prettau: D = DP > DPG > DG = C; e Prettau Anterior DPG = C = D = DP > DG = DPG. O EH aumentou a RF dos grupos D e DP para Prettau e reduziu a RF do grupo DG para Prettau Anterior. O grupo D p... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The CAD/CAM technology allowed prosthesis with accurate fit, but clinical adjustments are still necessary, and there is no protocol in the literature to guide how to provide it. The aim of this study is to evaluate the effect of grinding and finishing procedures on flexural strength (FS) and Weibull moduli, roughness (Ra) and phase transformation by Scanning Electronic Microscopy (SEM) of two monolithic zirconia (Prettau and Prettau Anterior) submitted to low temperature degradation (LTD). It was obtained bar-shaped specimens in the dimensions of 20 x 4.0 x 1.2 mm, without grinding and with glaze (control group) or 20 x 4.0 x 1.5 mm which were ground with diamond burr (90-120 μm) in high rotation and constant water cooling. After 0.3 mm of grinding, the samples were submitted to different finishing protocols: without polishing (D); polishing with diamond rubber (DP); glaze application (DG); polishing with diamond rubber + glaze (DPG). Half of samples was submitted to LTD in autoclave (134 °C, 2 bars, 20 hours). FS and Ra (n=30) data were analyzed by Kruskal-Wallis test and post-hot Dunn and Student-Newman-Keuls, respectively (α=.05). The median FS for Prettau, without LTD, was in the following order: D = DP > DPG > DG = C; Prettau Anterior: D = DP = C > DG = DPG. After LTD, Prettau: D = DP > DPG > DG = C; and Prettau Anterior: DPG = C = D = DP > DG = DPG. LTD increased FS of D and DP Prettau groups, and it decreased FS of DG Prettau Anterior group. Irrespectively of material ... (Complete abstract click electronic access below) / Doutor
22

Efeito do desgaste e ciclo térmico de regeneração sobre o limite de fadiga de uma Y-TZP e sobre a resistência flexural e de união de corpos-de-prova bicamada Y-TZP/cerâmica feldspática /

Polli, Gabriela Scatimburgo January 2018 (has links)
Orientador: José Maurício dos Santos Nunes Reis / Resumo: O objetivo deste estudo foi avaliar o efeito do desgaste e do ciclo térmico de regeneração (R) no limite de fadiga flexural e na caracterização superficial da cerâmica LavaTM Y-TZP e avaliar a influência de métodos de desgaste e do R sobre a resistência à flexão e de união da cerâmica LavaTM Y-TZP recoberta por cerâmica de cobertura. Foram obtidos espécimes em forma de barra (20 x 4,0 x 1,2 mm, n=40; 20 x 4,0 x 1,5 mm, N=80). Metade das barras de 1,2 mm constituíram o grupo controle (C), enquanto as de 1,5 mm foram desgastadas sob irrigação (DI) ou não (D). A outra metade dos espécimes de 1,2 mm e das desgastadas foram submetidas ao R (1000 ºC, 30 min), gerando os grupos CR, DIR e DR. O limite de fadiga (500.000 ciclos, 10 Hz) foi avaliado pelo método de escada. A topografia da superfície (n=3) e a área da fratura (n=3) foram avaliadas por MEV. Transformação de fase foi avaliada por difração de raios-X. Os dados de limite de fadiga foram submetidos ao teste ANOVA dois fatores e Tukey (α=0,05). Além disso, barras (N=72) de Y-TZP nas dimensões 20 x 4,0 x 1,20 mm (Controle (C); n=24) e 20 x 4,0 x 1,50 mm (n=48) foram obtidas. Os espécimes com 1,50 mm de altura foram desgastadas, com fresa diamantada (DF) ou pedra específica para zircônia (DP). Metade dos espécimes do grupo Controle e metade das desgastadas foram submetidas ao R (CR, DFR e DPR). Em seguida, a cerâmica de cobertura IPS e.max Ceram foi aplicada sobre todos os espécimes, sendo a dimensão final dos espécimes de 20 x ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the effect of grinding and regeneration cycle (R) on the flexural fatigue limit and on the surface characterization of LavaTM Y-TZP ceramics and evaluate the influence of grinding methods and of R on the flexural strength and bonding strength between LavaTM Y-TZP and veneering porcelain specimens. Bar-shaped specimens (20 x 4.0 x 1.2 mm, n = 40; 20 x 4.0 x 1.5 mm, N=80) were obtained. Half of the 1.2 mm specimens was the control group (C), while the 1.5 mm specimens were ground under irrigation (DI) or not (D). Half of ground specimens and half of the 1.2 mm specimens were submitted to R (1000 ° C, 30 min), forming the groups CR, DIR and DR. The fatigue limit (500,000 cycles, 10 Hz) was evaluated by the staircase method. Surface topography (n=3) and fracture area (n=3) were evaluated by SEM. Phase transformation was evaluated by X-ray diffraction. Fatigue limit data were analyzed by two-way ANOVA and Tukey tests (α=.05). Moreover, Y-TZP bars (N=72) in the dimensions of 20 x 4.0 x 1.20 mm (Control (C); n=24) and 20 x 4.0 x 1.50 mm (n=48) were obtained. The specimens with 1.50 mm in height were ground, with diamond burs (DF) or zirconia stone (DP). Half of the specimens of the Control group and half of ground ones were submitted to R (CR, DFR and DPR). Then, veneering porcelain (IPS e.max Ceramic) was applied over all specimens, acquiring the final dimension of 20 x 5.0 x 2.4 mm. The monotonic flexural strength test was performed. Data were... (Complete abstract click electronic access below) / Doutor
23

Analise "in vitro" da infiltração bacteriana e das adaptações na interface implante/conector protetico de sistemas de implantes endosseos / In vitro analysis of bacterial leakage and the implant/abutment interface adaptation of systems of endosseous implants

Oliveira, Greison Rabelo de 20 February 2006 (has links)
Orientador: Jose Ricardo Albergaria Barbosa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-06T03:00:59Z (GMT). No. of bitstreams: 1 Oliveira_GreisonRabelode_M.pdf: 6578630 bytes, checksum: 77bd8ffe12b316550fcd3c7a8ce3dc9c (MD5) Previous issue date: 2006 / Resumo: O propósito deste estudo foi avaliar in vitro a contaminação bacteriana através da interface implante/conector protético de quatro marcas comerciais de implantes endósseos de titânio comercialmente puro, buscando correlacioná-la com as dimensões dos microespaços e das adaptações na referida interface. Todos os sistemas empregados foram de fabricação nacional. Para isto, utilizaram-se, 80 implantes de dois estágios cirúrgicos, com seus respectivos conectores protéticos, sendo 40 Hexágonos Externo e 40 Hexágono Interno, divididos em 08 grupos de acordo com as marcas comercias e tipo de hexágono, contendo 10 implantes cada grupo. Grupo 1HE (10 implantes HE Master Screw®) e grupo 1HI (10 implantes HI Master Conect AR®), grupo 2HE (10 implantes HE INP Teres®) e grupo 2HI (10 implantes HI INP®), grupo 3HE (10 implantes HE Titamax®) e grupo 3HI (10 implantes HI Titamax II®), e grupo 4HE (10 implantes HE Serson®) e grupo 4 HI (10 implantes HI Serson Implus®). A análise microbiológica foi realizada após a incubação da espécie Streptococcus sanguis na parte interna do implante. Os implantes foram removidos das embalagens e manipulados com pinças estéreis ao redor do bico de Bunsen, de maneira que não perdessem as características de fabricação ou sofressem qualquer tipo de contaminação externa. Em seguida foi realizada a adaptação de um conector protético parafusado manualmente a um torque que variou de 20 a 30 Ncm de acordo com as recomendações dos fabricantes. A composição foi inserida em um meio de cultura BHI (Brain Heart Infusion) armazenada em uma estufa bacteriológica por um período de 30 dias até que ocorresse ou não contaminação externa do meio BHI. Leituras diárias para verificação da contaminação foram realizadas nesse período. Após os 30 dias todos os implantes foram submetidos a uma análise em microscopia eletrônica de varredura para a verificação das dimensões dos microespaços na interface implante/conector protético, com aumento variando de 25 vezes até 2500 vezes. Observou-se uma grande diferença no grau de contaminação bacteriana entre as marcas de implantes variando de 0 % para os implantes Titamax II® (Neodent - hexágono interno) e Serson® (Serson - hexágono externo), até 90% para os implantes Teres® (INP - hexágono externo), apresentando diferenças estatísticas significativas. Porém, considerando-se apenas os tipos de hexágono, de um modo geral, pode-se verificar que não houve diferença estatisticamente significante, no grau de contaminação bacteriana entre os implantes de hexágono externo e interno. Sendo que a média do microespaço na interface implante/conector protético, encontrada na análise de microscopia eletrônica de varredura não apresentou correlação com o grau de contaminação bacteriana / Abstract: The purpose of this study was to evaluate in vitro the bacterial contamination through the implant/ prosthetic connector interface of four commercial brands of commercially pure titanium endosseous implants, and correlate it with the microgap dimensions in this interface. All implant systems are nationally manufactured. Eighty two-stage implants and their respective prosthetic connectors (40 external hexagon - HE and 40 internal hexagon - HI) were divided into 8 groups of 10 implants each, according to the commercial brands and hexagon type. Group 1HE (10 implants HE Master Screw®), group 1HI (10 implants HI Master Conect AR®), group 2HE (10 implants HE INP Teres®), group 2HI (10 implants HI INP®), group 3HE (10 implants HE Titamax®), group 3HI (10 implants HI Titamax II®), group 4HE (10 implants HE Serson®) and group 4HI (10 implants HI Serson Implus®). The microbiological analysis was performed by incubation of Streptococcus sanguis in the internal part of the implants. The implants were removed from their packages and manipulated with sterile tweezers near a Bunsen burner, to prevent contamination or loss of their characteristics. A prosthetic connector was then adapted manually with a 20 to 30 Ncm torque, according to the manufacturers¿ recommendations. The composition was inserted in a Brain Heart Infusion (BHI) culture medium, and stored in a bacteriological stove for a period of 30 days, until the external contamination of the BHI medium could be assessed. Daily evaluations to verify the contamination were performed in this period. After 30 days, all implants were subjected to a scanning electron microscopic (SEM) analysis to assess the dimension of the microgaps in the implant/ prosthetic connector interface, under a 25 to 2500x magnification. Different contamination degrees of the groups could be observed, varying from zero% in brands Titamax II® (Neodent - internal hexagon) and Serson® (Serson - hexagon external), to 90% in the implants Teres® (INP - hexagon external), with statistically significant differences. However, when all HE and all HI implants were compared, there was no significant difference in the contamination degrees between external and internal hexagon implants. The mean microgap in the implant/ prosthetic connector interface, found in the SEM, did not present a correlation with the bacterial contamination degrees / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica
24

Analise dos efeitos da interação entre S mutans e materiais restauradores esteticos : caracteristicas do biofilme em microscopio confocal de varredura a laser e propriedades de superficie dos materiais apos 30 dias / Analysis of the interaction between S. mutans and esthetic restorative materials : biofilm chracteristics by confocal laser scanning microscopy and material surface properties after 30 days

Fúcio, Suzana Beatriz Portugal de 02 July 2007 (has links)
Orientadores: Regina Maria Puppin Rontani, Renata de Oliveira Mattos-Graner / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-08T10:43:29Z (GMT). No. of bitstreams: 1 Fucio_SuzanaBeatrizPortugalde_M.pdf: 1914666 bytes, checksum: 2dbf8bdbcedb3127f232b29d0b441c5b (MD5) Previous issue date: 2007 / Resumo: O desenvolvimento do biofilme de Streptococcus mutans sobre materiais restauradores e a biodegradação destes substratos em função dos metabólitos bacterianos podem ser influenciados pelas propriedades e características do material. A partir de uma revisão sistemática em que se verificou a carrência de estudos a respeito dos efeitos do biofilme na superície de materiais restauradores, foi proposto investigar algumas características quantitativas e qualitativas do biofilme após 30 dias de interação com materiais restauradores, além de analisar propriedades e microestrutura da superfície dos materiais que sofreram tal interação. Para cada material testado (cerâmica - C, resina composta nanoparticulada e cimentos de inúmero de vidro modificado por resina - CIVMR e convencional - CIVC), foram confeccionados 25 discos sob condições assépticas, para distribuição em 3 grupos de estocagem: 1) 100% de umidade relativa a 37ºC (n=5); 2) meio de cultura a 37ºC (BHI + 1% sacarose) (n=5); 3) biofilme de Streptococcus mutans e meio de cultura a 37ºC (n=15). Valores de dureza do grupo 1 (valores imediatos) foram obtidos previamente à estocagem, a fim de se verificar alterações ao longo do tempo quando estocados em umidade relativa apenas. Após 30 dias de estocagem, os discos do grupo 3 foram levados para observação do biofilme corado e hidratado em microscopia de varredura confocal a laser (CLSM). As imagens obtidas auxiliaram na obtenção de valores / Abstract: Streptococcus mutans biofilm development on restorative materials and biodegradation of those materials due to bacterial acids are influenced by material properties and characteristics. Since a systematic review found a deficiency concerning studies related to effects of biofilm on the surface of restorative materials, the proposition for this investigation was to analyze some quantitative and qualitative biofilm characteristics after 30-days interaction with restorative materials. In addition, it was investigated changes on the surface properties and microstructure of materials after 30-days interaction. Twenty-five disks of each material tested (ceramic - C, nanofill composite - NC, resin-modified glass ionomer - RMGIC and conventional glass ionomer cement - CGIC) were made, at aseptic conditions, and distributed in 3 storage groups: 1) 100% relative humidity at 37ºC (n=5); 2) growth medium at 37ºC (BHI + 1% sucrose) (n=5); 3) Streptococcus mutans biofilm and growth medium at 37ºC (n=15). Vickers hardness values from group 1 were obtained previously storage, in order to observe aging by relative humidity. After 30 days storage, disks were stained, kept hydrated and observed by confocal laser scanning microscopy, whose images supported to acquire values concerning biofilm thickness, bio-volume, roughness coefficient and surface to volume ratio. Qualitative analyses related to viable / non-viable cells distribution and biofilm architecture also were realized. Subsequently, all disks were ultrasonically washed and analyzed to surface roughness, hardness and microstructure. Biofilms presented a progression more viable cells in superficial regions of the biofilm to proportionally more nonviable cells in the deeper regions of the biofilms, near the disk. Besides, cellular aggregates and fluid-filled channels were observed in biofilm developed on all materials. Concerning biofilm quantitative properties, thickness was the unique with difference statistically significant among materials. C and NC accumulated thicker biofilms than RMGIC and CGIC. There was no difference statistically significant among immediate and storage groups related to C and NC surface roughness and hardness. However, group 3 of NC showed surface biodegradation microscopically. Group 1 of RMGIC and CGIC presented higher hardness values than immediate values. Nevertheless, hardness values from RMGIC group 3 decreased compared groups 1 and 2, while surface roughness values of group 3 increased statistically. Group 3 of CGIC showed higher roughness values than other groups and no difference statistically significant among three storage groups concerning hardness values. RMGIC and CGIC micrographs also demonstrated biodegradation on the surface materials. Within this study conditions, it was concluded that there was influence of restorative materials on biofilm development and influence of biofilm on the surface properties and microstructure characteristics of materials tested, being material -dependent / Mestrado / Materiais Dentarios / Doutor em Materiais Dentários
25

Efeito das tecnologias alternativas para preparo cavitario nos procedimentos adesivos com sistemas autocondicionates

Oliveira, Marcelo Tavares de 25 February 2005 (has links)
Orientadores: Marcelo Giannini, Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T03:24:00Z (GMT). No. of bitstreams: 1 Oliveira_MarceloTavaresde_M.pdf: 5082541 bytes, checksum: c0624f8aeb1f1de12e33ab3c2ce83f13 (MD5) Previous issue date: 2005 / Resumo: O objetivo deste estudo foi avaliar o efeito de técnicas de preparo cavitário nos procedimentos adesivos com sistemas autocondicionantes. Foram analisadas as resistências à tração da união após os tratamentos, assim como, em microscopia eletrônica de varredura (MEV), as características morfológicas das estruturas formadas na região da união dentina-compósito; a morfologia da superfície produzida pelos tratamentos utilizados para preparar a dentina e o padrão de fratura dos espécimes testados no ensaio de microtração. Foram utilizados 208 terceiros molares humanos, que tiveram a superfície oclusal removida para a exposição de dentina de profundidade superficial e foram divididos aleatoriamente em 32 grupos experimentais. As tecnologias de preparo cavitário foram: ausência de smear layer, abrasionamento com lixas de SiC 600, ponta diamantada (100µm),broca carboneto de tungstênio (10 lâminas), aplicação de jato de óxido de alumínio 271µm,aplicação de laser Er:YAG, ponta diamantada CVD em ultra-som e Carisolv®.Após o tratamento superficial foi aplicado um dos sistemas adesivos de acordo com as instruções dos fabricantes (Tyrian, Clearfil SE Bond, Unifil Bond e Single Bond), em seguida restaurados com o compósito Clearfil AP-X. Os dentes foram armazenados em água destilada a 3rC durante 24 horas. Após esse período, os dentes foram seccionados perpedicularmente a interface de união, nos sentidos mésio-distal e vestíbulo-lingual, com a finalidade de se obter palitos com área de secção transversal de 0,7mm2. Os espécimes foram testados com o ensaio de microtração numa velocidade de 0,5mm/min até a ruptura. Os resultados foram analisados com ANOVA dois-critérios e teste Tukey. Foi identificada uma interação entre os tratamentos e os sistemas adesivos (p<0,00003).O tratamento com o laser de Er:YAG na condição do experimento e a ponta diamantada CVD em ultra-som apresentaram os piores resultados para todos os sistemas. O Carisolv® apresentou valores de resistência de união intermediários, porém os adesivos autocondicionantes mostraram resultados inferiores ao Single Bond. A ponta diamantada, a broca carboneto de tungstênio e a lixa de SiC 600 mostraram os resultados semelhantes. A abrasão a ar proporcionou maiores valores de resistência de união para o Clearfil SE Bond que apresentou resultado superior ao Tyrian. Os sistemas Clearfil SE Bond e Single Bond foram superiores, obtendo os maiores valores na ausência de smear layer, no entanto, o Unifil Bond foi semelhante ao Single Bond. As análises em MEV revelaram variações na formação da camada híbrida e uma predominância do padrão de fratura com falha adesiva entre o sistema de união e a dentina, e parcialmente coesiva no sistema de união. Foi observado que existe uma forte dependência entre as tecnologias utilizadas para a realização dos preparos cavitários e os sistemas de união, porém a técnica do condicionamento com ácido fosfórico pode reduzir o efeito das tecnologias sobre a resistência de união, exceto pela aplicação do laser de Er:YAG e da ponta diamantada CVD em ultra-som / Abstract: The aim of this study was to evaluate the effect of alternative cavity preparation techniques on the adhesive procedures with self-etching adhesive systems. Microtensile bond strength tests (µTBS), as well as, analysis under scanning electron microscope (SEM) of the morphological characteristics of the bonded structures, treated dentin surfaces and the failure mode of the tested specimens were performed. 208 third human molars had their oclusal surface flattened in order to expose superficial dentin. Teeth were randomly assigned to 32 experimental groups. Cavity preparation techniques used in this study were: smear layer free surface, 600-grit SiC paper, diamond bur (100µm,)carbide bur (10 blades), air abrasion, Er:YAG laser, CVD diamond bur - sonoabrasion and Carisolv® gel. Following each surface treatment, adhesive systems (Tyrian, Clearfil SE Bond, Unifil Bond and Single Bond) were applied according to manufacturer's instructions and 6mm high blocks were incrementally built up with Clearfil AP-X (Kuraray) composite resin. The specimens were stored for 24 hours at 37°C in distilled water and were serially sectioned in both mesio-distal and buccal-lingual directions transversally to the bonded interface to obtain an array of bonded beams with a cross-sectional area of 0.7mm2. Beams were tested in tension (0.5mm/min - Instron 4411) and results were analyzed with two-way ANOVA and Tukey's test. It was found an interaction between adhesive systems and surface treatments (p<0.00003). Sonoabrasion and laser treatment yielded the lowest values for the tested adhesive systems; Carisolv® gel showed intermediate bond strength, however, self-etching adhesive systems were worse than Single Bond. Diamond bur, carbide bur and 600-grit SiC paper had similar results. Air-abrasion produced improved results for adhesion with Clearfil SE Bond that was significantly better than Tyrian. Clearfil SE Bond and Single Bond were superior, obtaining the highest values of The aim of this study was to evaluate the effect of alternative cavity preparation techniques on the adhesive procedures with self-etching adhesive systems. Microtensile bond strength tests (µTBS), as well as, analysis under scanning electron microscope (SEM) of the morphological characteristics of the bonded structures, treated dentin surfaces and the failure mode of the tested specimens were performed. 208 third human molars had their oclusal surface flattened in order to expose superficial dentin. Teeth were randomly assigned to 32 experimental groups. Cavity preparation techniques used in this study were: smear layer free surface, 600-grit SiC paper, diamond bur (100µm,)carbide bur (10 blades), air abrasion, Er:YAG laser, CVD diamond bur - sonoabrasion and Carisolv®gel. Following each surface treatment, adhesive systems (Tyrian, Clearfil SE Bond, Unifil Bond and Single Bond) were applied according to manufacturer's instructions and 6mm high blocks were incrementally built up with Clearfil AP-X (Kuraray) composite resin. The specimens were stored for 24 hours at 37°C in distilled water and were serially sectioned in both mesio-distal and buccal-lingual directions transversally to the bonded interface to obtain an array of bonded beams with a cross-sectional area of O.7mm2. Beams were tested in tension (0.5mm/min - Instron 4411) and results were analyzed with two-way ANOVA and Tukey's test. It was found an interaction between adhesive systems and surface treatments (p<0.00003). Sonoabrasion and laser treatment yielded the lowest values for the tested adhesive systems; Carisolv® gel showed intermediate bond strength, however, self-etching adhesive systems were worse than Single Bond. Diamond bur, carbide bur and 600-grit SiC paper had similar results. Air-abrasion produced improved results for adhesion with Clearfil SE Bond that was significantly better than Tyrian. Clearfil SE Bond and Single Bond were superior, obtaining the highest values of µTBS for the smear layer free surface, although in the comparison among the adhesive systems Unifil Bond and Single Bond were similar. SEM analysis revealed some variations in the hybrid layer formation and the predominance of an adhesive failure between adhesive system and dentin, and partially cohesive in the adhesive system. It was also observed that there is a strong relationship between cavity preparation techniques and adhesive systems, however, the total-etch technique seems to levei the effect over the µTBS, except for the Er:YAG laser treatment and sonoabrasion / Mestrado / Dentística / Mestre em Clínica Odontológica
26

Avaliação da superfície do esmalte dentário por microscopia eletrônica de varredura após a remoção do bráquete e polimento /

Pignatta, Lilian Maria Brisque. January 2006 (has links)
Orientador: Eduardo César Almada Santos / Banca: José Rino Neto / Banca: Francisco Antonio Bertoz / Resumo: Introdução: a preservação da estrutura de esmalte após a remoção dos acessórios ortodônticos é uma obrigação do clínico. Portanto, procura-se um protocolo de descolagem com bases científicas. Objetivou-se neste trabalho avaliar por Microscopia Eletrônica de Varredura (MEV) a influência de quatro protocolos de remoção de bráquetes e polimento da superfície do esmalte e propor um protocolo que minimizasse os danos na superfície do esmalte. Material e método: doze incisivos permanentes bovinos foram divididos em quatro grupos de acordo com os instrumentos utilizados para a descolagem dos bráquetes e remoção do remanescente adesivo. Os bráquetes foram descolados com o alicate de descolagem reto (Ormco Corp.) nos grupos 1 e 2, e com o instrumento de descolagem Lift-Off (3M Unitek) nos grupos 3 e 4. Os remanescentes adesivos dos grupos 1 e 3 foram removidos com o alicate removedor de resina longo (Ormco Corp.) e dos grupos 2 e 4 com broca de carboneto de tungstênio (Beavers Dental) em alta-rotação com constante refrigeração de água. As superfícies, após cada etapa da descolagem e polimento, foram avaliadas em réplicas de resina epóxica e foram obtidas eletromicrografias com aumento de 50 e 200X em todos os grupos. Resultado: os quatro protocolos de remoção de acessórios ortodônticos e polimento ocasionaram irregularidades no esmalte. Conclusão: a remoção do bráquete com o alicate de descolagem reto, seguido da remoção do remanescente adesivo com broca de carboneto de tungstênio e polimento final com pasta de pedra-pomes foi o procedimento que ocasionou menores danos ao esmalte, sendo o protocolo sugerido para a remoção dos acessórios ortodônticos. / Abstract: Introduction: the preservation of the enamel structure after the removal of the orthodontic accessories is an obligation of the clinical. Therefore, a protocol of debonding with scientific bases is searched. The aim of this work was to evaluate through Scanning Electronic Microscopy (SEM) the influence of four protocols of bracket’s removal and polishing on the enamel and to recommend a protocol that minimized the damages to the enamel surface. Methods: twelve permanent bovine incisors were divided into four groups according to the instruments used to debond and remove of adhesive remnants. The brackets were removed with straight debonding pliers (Ormco Corp.) in the groups 1 and 2, and with Lift-Off debonding instrument (3M Unitek) in the Groups 3 and 4. The adhesive remnants in the groups 1 and 3 were removed with the adhesive removing pliers (Ormco Corp.) and in the groups 2 and 4 with high speed tungsten carbide bur with constant water refrigeration (Beavers Dental). The surfaces, after each step of debonding and polishing were evaluated in replicas of epoxy resin and were obtained electromicrographies with magnification of 50 and 200X in all groups. Results: the four removal protocols of orthodontic accessories and polishing caused irregularities to the enamel. Conclusion: the bracket’s removal with straight debonding pliers, followed by the removal of the adhesive remnants with tungsten carbide bur and final polishing with pumice was the procedure that caused less damage to enamel, being the suggested protocol for removal of orthodontic accessories. / Mestre
27

Structural and spectroscopic studies of surfaces on the nanometre scale

Festy, Frederic January 2000 (has links)
No description available.
28

Efeito da espessura da camada de cimento na integridade e resistência adesiva de pinos de resina reforçados por fibra de vidro / Effect of the thickness of the resin cement on the bond integrity and strength of glass fiber fiber-reinforced composite post

Reis, Katia Rodrigues 05 June 2009 (has links)
A perda de adesao e uma falha comum reportada para os pinos reforçados por fibra e usualmente ocorre ao longo da interface adesiva entre a dentina radicular e o cimento resinoso. A espessura de cimento resinoso ideal para preservar a continuidade da interface adesiva cimento-dentina e aumentar a retencao do pino e desconhecida. O objetivo deste estudo foi avaliar a influencia da espessura do cimento na integridade e na resistencia adesiva de dois cimentos resinosos empregados para a cimentacao de pinos reforcados por fibra. Trinta incisivos laterais superiores humanos com comprimentos radiculares semelhantes foram selecionados, secionados na juncao cimento-esmalte e tratados endodonticamente. As raizes foram aleatoriamente divididas em seis grupos (n=5), e os condutos radiculares foram preparados a uma profundidade de 8 mm usando uma das três brocas com diametro diferente: Broca Largo n 3 para o grupo controle (L3 1 mm); Broca Largo n&#8501; 4 (L4 - 1,25 mm) e Broca Largo n&#8501; 5 (L5 1,5 mm) para os grupos experimentais. Pinos de resina reforcados por fibra de vidro (Fibrekor post, Jeneric Pentron), 1 mm de diametro, foram cimentados aos condutos radiculares utilizando o cimento resinoso dual (Duolink, Bisco) ou o cimento resinoso autopolimerizavel (C&B Cement, Bisco). A porcao de cada especime contendo os pinos reforcados por fibra foi secionada transversalmente em tres secoes (cervical, media e apical) de 2 mm de espessura utilizando um disco diamantado em maquina de corte seriado sob refrigeracao com agua. As secoes foram polidas, limpas ultrassonicamente e duplicadas com polivinil siloxano. Replicas em resina epoxica das secoes foram obtidas para a mensuracao da espessura do cimento e da integridade adesiva na interface cimento-dentina por meio de MEV. As secoes foram armazenadas em solucao fisiologica a 37o C por uma semana e, entao, submetidas ao teste push-out em uma maquina de ensaio universal a velocidade de 0,5 mm/min-1, e a forca maxima requerida para deslocar cada pino foi registrada (N). Os dados foram analisados usando ANOVA a um criterio, teste de Tukey e teste t de Student (&#945;=0,05). A correlacao entre a integridade adesiva, a resistencia adesiva e a espessura do cimento tambem foi determinada pelo coeficiente de Pearson (&#945;=0,05). A comparacao multipla entre as condicoes experimentais para cada cimento revelou que os valores medios de integridade adesiva (%) e de resistencia adesiva (MPa) dos pinos reforcados por fibra cimentados com o cimento resinoso Duolink foram significantemente maiores no grupo controle (L3: 61,79 ± 18,06 e 11,32 ± 4,66) do que no grupo experimental com camada de cimento muito espessa (L5: 38,91 ± 5,75 e 4,68 ± 2,16) (p=0,018 e p=0,035), respectivamente. Embora nao tenha sido observada diferenca significante na integridade adesiva entre as diferentes espessuras de cimento avaliadas para o cimento resinoso C&B Cement (p>0,05), o grupo com camada de cimento muito espessa (L5: 10,67 ± 4,59) foi significantemente mais retentivo do que o grupo controle (L3: 4,01 ± 0,76) (p=0,014). A comparacao entre cimentos para cada condicao experimental mostrou que o cimento resinoso Duolink foi mais retentivo do que o cimento resinoso C&B Cement no grupo controle (11,32 ± 4,66 e 4,01 ± 0,76, p=0,008), ao passo que o cimento resinoso C&B Cement foi mais retentivo do que o cimento resinoso Duolink em L5 (4,68 ± 2,19 e 10,67 ± 4,59, p=0,030), respectivamente. Somente a comparação entre o grupo experimental L4 e os outros grupos nao foi significante para ambos os cimentos resinosos e testes realizados. O aumento da espessura do cimento diminuiu significantemente a integridade adesiva (r=-0,5901; p=0,021) e a resistência adesiva (r=-0,5387; p=0,038) para o cimento resinoso Duolink. A integridade adesiva correlacionou-se positivamente com a resistencia adesiva para esse tipo de cimento resinoso (r=0,6855; p=0,005). Diferentemente, nao foi encontrada correlação significante entre a espessura do cimento e a integridade adesiva (r=0,153; p=0,586) e nem entre a integridade adesiva e a resistencia adesiva (r=0,2969; p=0,283) registradas para C&B Cement. Contudo, o aumento da espessura deste tipo de cimento resinoso aumentou significantemente a retencao do pino (r=0,6576; p=0,008). Os dados sugeriram que a espessura da camada dos cimentos resinosos influenciou a integridade adesiva e a resistencia adesiva dos pinos de resina reforcados por fibra. Para o cimento resinoso Duolink selecionado, os maiores valores de integridade adesiva e de resistencia adesiva foram obtidos quando a camada mais fina de cimento foi testada (L3). Contudo, o cimento resinoso C&B Cement apresentou maior retencao quando a espessura da camada de cimento aumentou muito (L5), embora a espessura do cimento nao tenha desempenhado um papel importante na integridade adesiva da interface cimento-dentina para esse cimento resinoso. / Debonding is the most common cause of failure reported for glass fiberreinforced composite posts and occurs frequently along the adhesive interface between the resin cement and the root dentin. The ideal thickness of the resin cement to preserve the continuity along the cement-dentin interface and to increase the retention of the post is unknown. The purpose of this study was to evaluate the influence of the thickness of the resin cement on the bond integrity and strength of two resin cements used for glass fiber-reinforced composite posts cementation. 30 human maxillary incisors with similar root dimensions were selected, sectioned at the amelocemental junction and endodontically treated. The roots were randomly divided into six groups (n=5), and the post spaces were prepared 8 mm deep using one of the three burs with different diameters: Largo bur n&#8501; 3 for the control group (L3 1- mm); Largo bur n&#8501; 4 (L4 1,25-mm) e Largo bur n&#8501; 5 (L5 1,5-mm) for the experimental groups. Fiber-reinforced composite posts (Fibrekor post, Jeneric Pentron), 1-mm diameter, were cemented to post spaces by using the dual-cure (Duolink, Bisco) or self-cure system (C&B Cement, Bisco). The portion of each specimen that contained the bonded fiber post was sectioned into three 2-mm thick serial slices (cervical, middle, apical) with the Isomet saw under water cooling. The slices were polished and ultrasonicated in deionized water. Polyvinyl siloxane impressions of the observable surfaces were taken and the surfaces replicated with epoxy resin for measuring of the thickness of the resin cement and the bond integrity by using MEV. The slices were stored in physiologic solution at 37o C for one week, and then submitted to the push-out test at a crosshead speed of 0.5 mm/min-1. The maximum force required to dislocate each post was registered (N). Data were analyzed by one-way ANOVA, Tukey test and t test (&#945;=0,05). The correlation between bond integrity, bond strength and thickness of the resin cement was also determined by correlation test (&#945;=0,05). The multiple comparison test between the experimental conditions for each resin cement showed that the mean values of bond integrity (%) and strength (MPa) of the fiber posts cemented with Duolink were significantly higher at the control group (L3: 61.79 ± 18.06 and 11.32 ± 4.66) than those obtained for the experimental groups with the thicker layer cement (L5: 38.91 ± 5.75 and 4.68 ± 2.16) (p=0.018 and p=0.035), respectively. Although there was no significant difference on the bond integrity between the different thicknesses evaluated for C&B Cement (p>0.05), the group with thicker layer (L5: 10.67 ± 4.59) was significantly more retentive than the control group (L3: 4.01 ± 0.76) (p=0.014). The comparison between cements for each experimental condition has showed that Duolink was more retentive than C&B Cement at the control group (11.32 ± 4,66 and 4.01 ± 0,76, p=0.008), whereas C&B Cement was more retentive than Duolink at L5 group (4.68 ± 2.19 and 10.67 ± 4.59, p=0.030), respectively. Only the comparison between the L4 experimental group and the others groups was not significant for both resin cements and tests conducted. The increase of the thickness of the cement significantly reduced the bond integrity (r=-0.5901; p=0.021) and strength (r=-0,5387; p=0.038) for Duolink. Bond integrity positively correlated with bond strength for this type of resin cement (r=0.6855; p=0.005). On the other hand, there was no significant correlation between the thickness of the cement and the bond integrity (r=0.153; p=0.586) and neither between the bond integrity and strength (r=0.2969; p=0.283) registered for C&B Cement. However, the increase of the thickness of this type of resin cement has significantly increased the retention of the post (r=0.6576; p=0.008). Data suggested that the thickness of resin cements affected both the bond integrity and strength of fiber posts. For the Duolink resin cement selected, the higher values of bond integrity and strength were obtained when the thinner layer was tested (L3). However, C&B Cement has showed higher retention when the thickness of the cement increased excessively (L5), though the thickness of the cement has not played a role on the bond integrity of the cement-dentin interface for this resin cement.
29

Osteoblastic cell adhesion on implant surfaces contaminated by Aggregatibacter actinomycetencomitans and treated by photodynamic therapy and chemical decontamination / Adesão de células osteoblásticas em superfícies de implantes contaminadas por Aggregatibacter actinomycetencomitans e tratadas com terapia fotodinâmica e descontaminação química

Balderrama, Ísis de Fátima 06 April 2018 (has links)
The decontamination process of titanium implants surface is important for the successful treatment of peri-implantitis. The methods of decontamination can be classified in two major groups: chemical or physical. However, the best method of decontamination of implant surfaces is yet undertermined. The aim of this study is to analyze the effectiveness of decontamination of titanium implants surface by chemical conditioning agents and photodynamic therapy, by Scanning Electron Microscopy (SEM) and to analyze the adhesion and proliferation of osteoblastic cells on the previously decontaminated surfaces. Commercially available implants of different brands: Biomet 3i® (Nanotite NT; Osseotite - OT), Straumann® (SLActive SLA) and Neodent® (Acqua Drive CM ACQ; Neoporos Drive CM CM) were acquired in the market and analyzed in SEM images in 3 different areas (n= 1/group) to determine surface roughness parameters and wettability properties. After that, the surface of dental implants was inoculated with Aggregatibacter actinomycetemcomitans (A.a.) strains for 4 days and prepared for SEM analysis to determine the percentage area of contamination in a software for image analysis. Samples were then decontaminated by two different chemical treatments (citric acid 10% and ethylenediamine tetraacetic acid EDTA - 24%) and photodynamic therapy (methylene blue associated with LASER), both with a 3-minutes application time. In the control group, surfaces were decontaminated with chlorhexidine 0.12% for 3 minutes. The area of decontamination was determined in ImageJ software for SEM images analysis. After decontamination, the adhesion and proliferation of human osteoblastic osteosarcoma cell lineage (Saos-2) on the surface of uncontaminated sterile implants (control; n: 1/period) and decontaminated implants (n: 3/period/group) were investigated. Saos-2 cells [5x104] were seeded on implant surfaces and incubated for 24h (adhesion assay) and 72h (proliferation assay), determined on SEM images. No significant differences were found among the different implants regarding roughness parameters, with exception Rv (SLA: 19.57}4.01 vs. OT: 8.36}7.91; p=0.0031). Chemical composition varied among implants depending on surface treatment, with all groups showing prevalence of Titanium. Values showed greater contact angle (wettability analysis) for NT (hydrophobic) and smaller for ACQ (highly hydrophilic) (p<0.0001). Nanotite/Biomet 3i® showed significantly greater percentage of area contaminated by bacteria (68.19% } 8.63%; p=0.050; Kruskal Wallis/Dunn) than ACQ (57.32% } 5.38%). Osseotite/Biomet 3i® resulted in a smaller remaining contaminated area (50.89% } 9.12%) after decontamination treatments. Increased Saos-2 cells adhesion and proliferation were observed on SLA after 24h (p= 0.0006; ANOVA/Tukey) and 72h (<0.001; ANOVA/Tukey). Decontaminated groups showed significantly less number of cells adhered to the surfaces at 24h and 72h than uncontaminated controls (p < 0.005; ANOVA post hoc Sidak). Regarding decontamination methods, no differences in the number of cells attached to implants treated by photodynamic therapy and chemical agents compared to chlorhexidine at 24h, but implants treated by photodynamic therapy and chemical agents showed greater number of cells attached after 72h. These findings suggest that surface characteristics influenced bacterial contamination and decontamination of implant surfaces; none of the decontamination methods were able to completely remove bacterial contamination, impairing cell adhesion and spreading. These findings may explain the varying clinical results of decontamination methods in re-osseointegration. / O processo de descontaminação de implantes de titânio é importante para o sucesso do tratamento da peri-implantitite. Os métodos de descontaminação podem ser classificados em dois maiores grupos: químico ou físico. Entretanto, o melhor método de descontaminação de superfícies de implantes está ainda indeterminado. O objetivo desse estudo é analisar a efetividade da descontaminação de implantes com superfície de titânio por agentes condicionantes químicos e terapia fotodinâmica, por Microscopia Eletrônica de Varredura (MEV) e analisar a adesão e proliferação de células osteoblásticas previamente com superfícies descontaminadas. Implantes disponíveis comercialmente de diferentes marcas: Biomet 3i® (Nanotite NT; Osseotite - OT), Straumann® (SLActive SLA) e Neodent® (Acqua Drive CM ACQ; Neoporos Drive CM CM) foram adquiridos no mercado e analisados em imagens de MEV em 3 diferentes áreas (n=1/grupo) para determinar o parâmetro de rugosidade da superfície e a propriedade de molhabilidade. Depois disso, a superfície dos implantes dentários foi inoculada com cepa de Aggregatibacter actinomycetemcomitans (A.a.) por 4 dias e preparada para análise da MEV afim de determinar a área de porcentagem da contaminação em um software de análise de imagem. Amostras foram então descontaminadas por dois diferentes tratamentos químicos (ácido citrico 10% e ácido etilenodiamino tetraacético- EDTA 24%) e terapia fotodinâmica (azul de metileno associado com LASER), ambos em 3 minutos com tempo de aplicação. No grupo controle, os implantes foram descontaminados com clorexidina 0.12% por 3 minutos. A área de descontaminação foi determinada no software Image J para análise das imagens de MEV. Depois da descontaminação, a adesão e proliferação da linhagem de células de osteosarcoma osteoblástica humana (Saos-2) em superfícies não contaminadas de implantes estéreis (controle; n: 1/período) e implantes descontaminados (n: 3/período/grupo) foram investigados. Células da Saos-2 [5x104] foram cultivadas sobre as superficies dos implantes e incubadas por 24 horas (ensaio de adesão) e 72 horas (ensaio de proliferação) e determinadas em imagens de MEV. Não foram encontradas diferenças significantes entre os implantes em relação a parâmetros de rugosidade, com exceção para Rv (SLA: 19.57±4.01 vs. OT: 8.36±7.91; p=0.0031). Houve variação na composição química dos implantes de acordo com o tratamento de superfície, com todos os grupos mostrando prevalência do Titânio. Houve maior ângulo de contato (análise de molhabilidade) para NT (hidrofóbico) e menor para ACQ (altamente hidrofílico; p<0.0001). Nanotite/Biomet 3i® mostrou porcentagem significativamente maior de área contaminada por bactérias (68.19% ± 8.63%; p=0.050; Kruskal Wallis/Dunn) que ACQ (57.32% ± 5.38%). Osseotite/Biomet 3i® resultou em significativa menor área contaminada remanescente (50.89% ± 9.12%) depois dos tratamentos de descontaminação. Foi observada maior adesão e proliferação de células Saos-2 em SLA após 24 (p= 0.0006; ANOVA/Tukey) e 72 horas (<0.001; ANOVA/Tukey). Os grupos descontaminados mostraram número significativamente menor de células aderidas às superfícies nos dois períodos de tempo comparativamente aos controles não contaminados (p < 0.005; ANOVA post hoc Sidak). Em relação aos métodos de descontaminação, não foram observadas diferenças no número de células aderidas aos implantes tratados por terapia fotodinâmica e agentes químicos comparados com clorexidina em 24 horas, mas os primeiros mostraram maior número de células aderidas depois de 72 horas. Esses achados sugeriram que as características de superfície influenciaram a contaminação bacteriana e a descontaminação de superfície; nenhum método de descontaminação é capaz de remover completamente a contaminação bacteriana, dificultando a adesão e proliferação celular. Esses achados poderiam explicar a variação de resultados clínicos nos métodos de descontaminação e obtenção de reosseointegração.
30

The effect of chromium on the evolution of dispersoids in Al-Mg-Si alloys

Kenyon, Michael January 2018 (has links)
Aluminium is increasingly being used in the automotive industry to reduce the weight of vehicles. It is the additions of transition elements such as Mn and Cr that can be picked up during recycling, that can form dispersoid particles during homogenisation. Dispersoids play a significant role in the recrystallization and texture development for wrought Al-Mg-Si alloys by inhibiting grain boundary motion. It is therefore important to understand the precipitation kinetics of such particles. The Mn+Cr dispersoid phases are currently thought to nucleate on β'-Mg1.8Si particles via an intermediate semi-coherent precipitate denoted the u-phase. In this study, Al-Mg-Si alloys with additions of Fe and varying levels of Cr were cast to study the effect of different homogenisation regimes on the dispersoid precipitation mechanisms and final characteristics. Electron Probe Micro Analysis (EPMA) was conducted to study the inhomogeneity of elements in the cast structure and through heating to the homogenisation temperature. It was found that Mg, Si and Fe segregate towards the dendrite edges during solidification while Cr segregates towards the dendrite centre. During heating, the matrix composition of both Mg and Si decrease and increase due to precipitation of Mg+Si phases. Cr and Fe stay segregated during the heating process due to the slower diffusion rates in the face centred cubic Al matrix. Dispersoid free regions have also been observed in the microstructure correlating to the elemental segregation in the as-cast condition. Optical, scanning and transmission electron microscopy was utilised in order to study the change in dispersoid characteristics with varying homogenisation regimes and as a function of distance through a grain. With an increase in homogenisation temperature, the mean size of dispersoids increased but number density decreased. For a longer dwell time, the dispersoids remained approximately the same size but increased in volume fraction and density. Increasing the heating rate did not significantly change the dispersoid size, volume fraction or density. The dispersoids size and number density was also studied as a function of distance through a number of grains with the interplay of nucleation, growth and coarsening discussed. Both α-Al(FeCr)Si and α'-AlCrSi dispersoids were found to exist with a variety of morphologies while the α'-AlCrSi dispersoids were found to have a larger effective diameter.

Page generated in 0.0895 seconds