• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 48
  • 29
  • 6
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 106
  • 106
  • 52
  • 50
  • 42
  • 34
  • 33
  • 11
  • 10
  • 10
  • 10
  • 8
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Efeito da espessura da camada de cimento na integridade e resistência adesiva de pinos de resina reforçados por fibra de vidro / Effect of the thickness of the resin cement on the bond integrity and strength of glass fiber fiber-reinforced composite post

Katia Rodrigues Reis 05 June 2009 (has links)
A perda de adesao e uma falha comum reportada para os pinos reforçados por fibra e usualmente ocorre ao longo da interface adesiva entre a dentina radicular e o cimento resinoso. A espessura de cimento resinoso ideal para preservar a continuidade da interface adesiva cimento-dentina e aumentar a retencao do pino e desconhecida. O objetivo deste estudo foi avaliar a influencia da espessura do cimento na integridade e na resistencia adesiva de dois cimentos resinosos empregados para a cimentacao de pinos reforcados por fibra. Trinta incisivos laterais superiores humanos com comprimentos radiculares semelhantes foram selecionados, secionados na juncao cimento-esmalte e tratados endodonticamente. As raizes foram aleatoriamente divididas em seis grupos (n=5), e os condutos radiculares foram preparados a uma profundidade de 8 mm usando uma das três brocas com diametro diferente: Broca Largo n 3 para o grupo controle (L3 1 mm); Broca Largo nℵ 4 (L4 - 1,25 mm) e Broca Largo nℵ 5 (L5 1,5 mm) para os grupos experimentais. Pinos de resina reforcados por fibra de vidro (Fibrekor post, Jeneric Pentron), 1 mm de diametro, foram cimentados aos condutos radiculares utilizando o cimento resinoso dual (Duolink, Bisco) ou o cimento resinoso autopolimerizavel (C&B Cement, Bisco). A porcao de cada especime contendo os pinos reforcados por fibra foi secionada transversalmente em tres secoes (cervical, media e apical) de 2 mm de espessura utilizando um disco diamantado em maquina de corte seriado sob refrigeracao com agua. As secoes foram polidas, limpas ultrassonicamente e duplicadas com polivinil siloxano. Replicas em resina epoxica das secoes foram obtidas para a mensuracao da espessura do cimento e da integridade adesiva na interface cimento-dentina por meio de MEV. As secoes foram armazenadas em solucao fisiologica a 37o C por uma semana e, entao, submetidas ao teste push-out em uma maquina de ensaio universal a velocidade de 0,5 mm/min-1, e a forca maxima requerida para deslocar cada pino foi registrada (N). Os dados foram analisados usando ANOVA a um criterio, teste de Tukey e teste t de Student (α=0,05). A correlacao entre a integridade adesiva, a resistencia adesiva e a espessura do cimento tambem foi determinada pelo coeficiente de Pearson (α=0,05). A comparacao multipla entre as condicoes experimentais para cada cimento revelou que os valores medios de integridade adesiva (%) e de resistencia adesiva (MPa) dos pinos reforcados por fibra cimentados com o cimento resinoso Duolink foram significantemente maiores no grupo controle (L3: 61,79 ± 18,06 e 11,32 ± 4,66) do que no grupo experimental com camada de cimento muito espessa (L5: 38,91 ± 5,75 e 4,68 ± 2,16) (p=0,018 e p=0,035), respectivamente. Embora nao tenha sido observada diferenca significante na integridade adesiva entre as diferentes espessuras de cimento avaliadas para o cimento resinoso C&B Cement (p>0,05), o grupo com camada de cimento muito espessa (L5: 10,67 ± 4,59) foi significantemente mais retentivo do que o grupo controle (L3: 4,01 ± 0,76) (p=0,014). A comparacao entre cimentos para cada condicao experimental mostrou que o cimento resinoso Duolink foi mais retentivo do que o cimento resinoso C&B Cement no grupo controle (11,32 ± 4,66 e 4,01 ± 0,76, p=0,008), ao passo que o cimento resinoso C&B Cement foi mais retentivo do que o cimento resinoso Duolink em L5 (4,68 ± 2,19 e 10,67 ± 4,59, p=0,030), respectivamente. Somente a comparação entre o grupo experimental L4 e os outros grupos nao foi significante para ambos os cimentos resinosos e testes realizados. O aumento da espessura do cimento diminuiu significantemente a integridade adesiva (r=-0,5901; p=0,021) e a resistência adesiva (r=-0,5387; p=0,038) para o cimento resinoso Duolink. A integridade adesiva correlacionou-se positivamente com a resistencia adesiva para esse tipo de cimento resinoso (r=0,6855; p=0,005). Diferentemente, nao foi encontrada correlação significante entre a espessura do cimento e a integridade adesiva (r=0,153; p=0,586) e nem entre a integridade adesiva e a resistencia adesiva (r=0,2969; p=0,283) registradas para C&B Cement. Contudo, o aumento da espessura deste tipo de cimento resinoso aumentou significantemente a retencao do pino (r=0,6576; p=0,008). Os dados sugeriram que a espessura da camada dos cimentos resinosos influenciou a integridade adesiva e a resistencia adesiva dos pinos de resina reforcados por fibra. Para o cimento resinoso Duolink selecionado, os maiores valores de integridade adesiva e de resistencia adesiva foram obtidos quando a camada mais fina de cimento foi testada (L3). Contudo, o cimento resinoso C&B Cement apresentou maior retencao quando a espessura da camada de cimento aumentou muito (L5), embora a espessura do cimento nao tenha desempenhado um papel importante na integridade adesiva da interface cimento-dentina para esse cimento resinoso. / Debonding is the most common cause of failure reported for glass fiberreinforced composite posts and occurs frequently along the adhesive interface between the resin cement and the root dentin. The ideal thickness of the resin cement to preserve the continuity along the cement-dentin interface and to increase the retention of the post is unknown. The purpose of this study was to evaluate the influence of the thickness of the resin cement on the bond integrity and strength of two resin cements used for glass fiber-reinforced composite posts cementation. 30 human maxillary incisors with similar root dimensions were selected, sectioned at the amelocemental junction and endodontically treated. The roots were randomly divided into six groups (n=5), and the post spaces were prepared 8 mm deep using one of the three burs with different diameters: Largo bur nℵ 3 for the control group (L3 1- mm); Largo bur nℵ 4 (L4 1,25-mm) e Largo bur nℵ 5 (L5 1,5-mm) for the experimental groups. Fiber-reinforced composite posts (Fibrekor post, Jeneric Pentron), 1-mm diameter, were cemented to post spaces by using the dual-cure (Duolink, Bisco) or self-cure system (C&B Cement, Bisco). The portion of each specimen that contained the bonded fiber post was sectioned into three 2-mm thick serial slices (cervical, middle, apical) with the Isomet saw under water cooling. The slices were polished and ultrasonicated in deionized water. Polyvinyl siloxane impressions of the observable surfaces were taken and the surfaces replicated with epoxy resin for measuring of the thickness of the resin cement and the bond integrity by using MEV. The slices were stored in physiologic solution at 37o C for one week, and then submitted to the push-out test at a crosshead speed of 0.5 mm/min-1. The maximum force required to dislocate each post was registered (N). Data were analyzed by one-way ANOVA, Tukey test and t test (α=0,05). The correlation between bond integrity, bond strength and thickness of the resin cement was also determined by correlation test (α=0,05). The multiple comparison test between the experimental conditions for each resin cement showed that the mean values of bond integrity (%) and strength (MPa) of the fiber posts cemented with Duolink were significantly higher at the control group (L3: 61.79 ± 18.06 and 11.32 ± 4.66) than those obtained for the experimental groups with the thicker layer cement (L5: 38.91 ± 5.75 and 4.68 ± 2.16) (p=0.018 and p=0.035), respectively. Although there was no significant difference on the bond integrity between the different thicknesses evaluated for C&B Cement (p>0.05), the group with thicker layer (L5: 10.67 ± 4.59) was significantly more retentive than the control group (L3: 4.01 ± 0.76) (p=0.014). The comparison between cements for each experimental condition has showed that Duolink was more retentive than C&B Cement at the control group (11.32 ± 4,66 and 4.01 ± 0,76, p=0.008), whereas C&B Cement was more retentive than Duolink at L5 group (4.68 ± 2.19 and 10.67 ± 4.59, p=0.030), respectively. Only the comparison between the L4 experimental group and the others groups was not significant for both resin cements and tests conducted. The increase of the thickness of the cement significantly reduced the bond integrity (r=-0.5901; p=0.021) and strength (r=-0,5387; p=0.038) for Duolink. Bond integrity positively correlated with bond strength for this type of resin cement (r=0.6855; p=0.005). On the other hand, there was no significant correlation between the thickness of the cement and the bond integrity (r=0.153; p=0.586) and neither between the bond integrity and strength (r=0.2969; p=0.283) registered for C&B Cement. However, the increase of the thickness of this type of resin cement has significantly increased the retention of the post (r=0.6576; p=0.008). Data suggested that the thickness of resin cements affected both the bond integrity and strength of fiber posts. For the Duolink resin cement selected, the higher values of bond integrity and strength were obtained when the thinner layer was tested (L3). However, C&B Cement has showed higher retention when the thickness of the cement increased excessively (L5), though the thickness of the cement has not played a role on the bond integrity of the cement-dentin interface for this resin cement.
42

Efeito do estresse crônico variado e da alteração oclusal sobre músculo masseter / Effects of varied chronic stress and occlusal alteration on the masseter muscle

Pereira, Yamba Carla Lara, 1981- 24 August 2018 (has links)
Orientadores: Pedro Duarte Novaes, Mamie Mizusaki Iyomasa / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T15:22:08Z (GMT). No. of bitstreams: 1 Pereira_YambaCarlaLara_D.pdf: 21699774 bytes, checksum: 6a8918dd0a94fb092cc529b6cdc3cd34 (MD5) Previous issue date: 2014 / Resumo: O estresse e as perdas dentais têm impacto sobre os músculos da mastigação favorecendo a dor, no entanto, a patogênese envolvida ainda é pouco compreendida. O objetivo deste trabalho foi investigar o efeito do estresse crônico variado em músculo masseter esquerdo de animais submetidos à alteração oclusal por exodontia unilateral, isolados ou associados, por meio de avaliação das atividades gelatinolíticas totais e da mieloperoxidase, análises morfológicas, imunoistoquímicas, histoquímicas e ultraestruturais ao Microscópio Eletrônico de Transmissão. Foram usados 20 ratos machos, Wistar, adultos jovens, pesando ± 200g, divididos aleatoriamente em 04 (quatro) grupos: (n=5): GI controle, sem alteração oclusal e sem estresse crônico variado (EV), G II- alteração oclusal isolada, G III EV isolado e G IV- alteração oclusal associada ao EV. Nos grupos da exodontia (GII e G IV), animais previamente anestesiados, tiveram os molares superiores esquerdos extraídos. Os grupos dos estresses (G III e G IV) foram submetidos a diferentes estressores a partir do 14º dia após a exodontia. Todos os animais foram eutanasiados no 24º dia. No feixe superficial, a análise dos resultados revelou que o músculo masseter, a exodontia e o EV, isolados ou associados não promoveram a infiltração de polimorfonucleares analisados por meio da mieloperoxidase e não alteraram os níveis das metaloproteinases (MMP-2) avaliados por meio da atividade de Gelatinase Total. No feixe anterior do músculo masseter profundo, a exodontia e o EV, isolados ou associados alteraram, em determinadas regiões, as características histológicas das fibras reveladas por coloração em hematoxilina e eosina; alteraram a ultraestrutura das mitocôndrias ao microscópio eletrônico de transmissão; revelaram regiões com lúmen reduzido, e outras com lúmen dilatado, em capilares marcados com anticorpo anti-laminina; revelaram uma tendência ao aumento da densidade de capilares imunomarcados por anti-alpha CD31 do endotélio, e não alteraram as escassas fibras imunomarcadas pela miosina do tipo I Neste mesmo feixe, diminuíram os níveis de espécies reativas de oxigênio no grupo exposto à exodontia (GII). No feixe médio posterior do músculo masseter profundo, os protocolos experimentais confirmaram a prevalência de fibras claras, por meio da reação histoquímica de succinato desidrogenase. Podemos concluir que o músculo masseter esquerdo manifestou alteração regional decorrente da exodontia e EV isolados ou associados, revelados por alterações morfológicas, ultraestruturais, hemodinâmicas e estresse oxidativo, em especial no feixe profundo anterior. Esses dados contribuem para a compreensão do desenvolvimento do ponto de gatilho. No entanto, novos estudos serão necessários para melhor entendimento da etiopatogenia da dor miofascial e da disfunção temporomandibular e sua relação com estresse e alteração oclusal / Abstract: Stress and tooth loss have an impact on the masticatory muscles favoring the pain. However, the pathogenesis involved is still little understood. The aim of this study was to investigate the effect of varied chronic stress in left masseter muscle of rats subjected to unilateral alteration by occlusal tooth extraction, alone or associated, through evaluation of total gelatinolytic activities and myeloperoxidase, morphological analysis, histochemical, immunohistochemical labeling and transmission electron microscope. Twenty male Wistar rats, young adults, weighing ± 200 g, were divided randomly into four groups (n=5): GI control without occlusal alteration and without varied chronic stress (EV), G II-occlusal alteration isolated, G III EV isolated and G IV-occlusal alteration associated with the EV. The rats from groups of dental extraction (GII and G IV) were previously anesthetized and had the superior left molars extracted. The groups of stresses (G III and G IV) were submitted to different stressors from the 14th day after the tooth extraction. All the animals were euthanized on the 24th day. On the surface, the beam analysis of results showed that the masseter muscle, dental extraction and the EV, alone or associated with not promoted the infiltration of polymorphonuclear scanned through the myeloperoxidase and not altered levels of metalloproteinases (MMP-2) evaluated by means of Total Gelatinase activity. In the anterior bundle of masseter muscle located evaluated through the Total Gelatinase activity. In anterior bundle of the deep masseter muscle, the dental extraction and the EV, alone or associated with altered, in some regions, the histological characteristics of the fibers revealed by hematoxylin and eosin staining; the ultrastructure of mitochondria in the transmission electron microscope; revealed areas with reduced lumen, and lumen distended in other capillaries marked with anti-laminina antibody; showed a tendency to increase in the density of capillaries labelled by endothelium, CD31 anti-alpha and have not altered the scarce labelled fibers by myosin type I in the same bundle, decreased levels of reactive oxygen species in the group exposed to dental extraction (GII). The average bundle of deep masseter muscle later, experimental protocols confirmed the prevalence of clear fibers by means of Immunohistochemistry reaction of succinate dehydrogenase. We can conclude that the masseter muscle change resulting from regional expressed left dental extraction and EV alone or associated, revealed by morphological, ultrastructural, and hemodynamic oxidative stress, especially in deep beam. These data contribute to the understanding of the development of the trigger point. However, further studies are needed to better understanding of the pathogenesis of myofascial pain and temporomandibular joint dysfunction and its relation with occlusal stress and occlusial alteration / Doutorado / Histologia e Embriologia / Doutora em Biologia Buco-Dental
43

Técnicas para cimentação de pinos de fibra de vidro = avaliação da resistência adesiva, nanoinfiltração e influência da clorexidina / Techniques for cementing of glass fiber post : evaluation of bond strength, nanoleakage and chlorhexidine

Pontes, Danielson Guedes, 1977- 18 August 2018 (has links)
Orientador: Luis Alexandre Maffei Sartini Paulillo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T20:41:22Z (GMT). No. of bitstreams: 1 Pontes_DanielsonGuedes_D.pdf: 2244175 bytes, checksum: e175c16412f9bcc592b5f82e347026a8 (MD5) Previous issue date: 2011 / Resumo: O objetivo deste estudo foi investigar a resistência de união entre pinos de fibra de vidro/dentina radicular através de "push-out" e nanoinfiltração, e ainda, a influência da solução irrigadora do canal radicular - clorexidina 2% - na qualidade da adesão de cimentos auto-adesivos. Método: Para o desenvolvimento deste estudo foram realizados dois experimentos. Noventa e oito raízes bovinas foram utilizadas no teste de push-out (n=10) e dezoito raízes foram separadas para a análise da nanoinfiltração (n=3) na interface de pinos de fibra de vidro cimentados com diferentes materiais, que foram divididas em 6 grupos: RelyX Unicem (UNC); RelyX U100 (UCE); Scothbond Multiuso Plus ativação química + RelyX CRA (ASR); Scothbond Multiuso Plus ativação física + RelyX CRA (SBR); Clearfil SE Bond/ED Prime + Panavia F 2.0 (CEP); Clearfil SE Bond + Panavia F 2.0 (CFP). Os pinos foram cimentados no canal radicular de acordo com as recomendações de cada fabricante. Para o ensaio de push-out, foram obtidas fatias com 1,0 mm de espessura dos terços cervical, médio e apical de cada raiz, e o teste foi conduzido em máquina de ensaio universal na velocidade de 0,5 mm por minuto. Para a análise da nanoinfiltração, as fatias foram imersas em solução de nitrato de prata amoniacal (AgNO3) para a microscopia eletrônica de varredura (MEV). Posteriormente, para a an lise da influência do digluconato de clorexidine na resistência à união e nanoinfiltração de cimentos auto-adesivos, foram formados 4 grupos: RelyX Unicem (UNC); RelyX U100 (UCE); Clorexidine 2% + RelyX Unicem (UNX); Clorexidine 2% + RelyX U100 (UCX). Os resultados foram analisados através de análise de variância com parcela subdividida (p<0,05). Resultados: Sistemas de fixação: Entre as técnicas de cimentação, no terço médio, o S mostrou a maior resistência com diferença estat stica para os sistemas EP, FP e UN . Somente o grupo FP apresentou diferença estat stica significativa entre os terços radiculares, com menor resultado no terço apical quando comparado ao terço cervical. No terço cervical, a menor média foi do grupo S apresentando diferença estat stica significativa para o grupo S . Nanoinfiltração: No terço apical o CFP apresentou a maior nanoinfiltração com diferença estatística significativa para os terços médio e cervical, e também para os outros sistemas. Clorexidina: O uso da clorexidina como solução irrigadora do canal radicular diminuiu significativamente a resistência adesiva dos cimentos auto-adesivos. Em todos os grupos houve a presença de nanoinfiltração e na interface adesiva e não foi observada a formação de camada híbrida. Conclusão: O uso de sistemas adesivos que empregam prévio condicionamento ácido e possuem ativação química possibilitou melhores resultados de resistência à união e melhor qualidade da camada híbrida. O uso de ativador químico para o sistema adesivo autocondicionante, permitiu melhora significativa da união na região mais profunda da raíz. A irrigação prévia do canal radicular com clorexidine 2% influenciou negativamente a resistência adesiva dos cimentos auto-adesivos / Abstract: The aim of this study was to investigate the bond interface between glass fiber post/root dentin by means of push-out and nanoleakage tests, as well as the influence of the root canal irrigant solution - 2% chlorhexidine - on the bond quality of self-adhesive cements. Methods: In order to develop this study two analysis were performed. Bovine roots were used in the push-out test (n=10) and eighteen roots were separated for analysis of nanoleakage (n=3) at the interface of glass fiber posts cemented with different adhesive techniques, which were divided into six groups: RelyX Unicem (UNC); RelyX U100 (UCE); Scotchbond Multipurpose chemical activation + RelyX ARC (ASR); Scotchbond Multipurpose physical activation + RelyX ARC (SBR); Clearfil SE Bond / ED Prime + Panavia F 2.0 (CEP); Clearfil SE Bond + Panavia F 2.0 (CFP). The posts were cemented in the root canal in accordance with the recommendations of each manufacturer. For the push-out test 1.0 mm thick slices were obtained of the cervical, middle and apical thirds of each root, and the test was conducted in a universal test machine at a speed of 0.5 mm per minute. To analyze nanoleakage, the disc-shaped specimens were immersed in ammoniacal silver nitrate solution (AgNO3) for scanning electron microscopy (SEM). Subsequently, to analyze the influence of 2% chlorhexidine digluconate in bond strength and nanoleakage of the self-adhesive cements, were formed four groups: RelyX Unicem (UNC); RelyX U100 (UCE); 2% Chlorhexidine + RelyX Unicem (UNX); 2% Chlorhexidine + RelyX U100 (UCX). The results were analyzed using analysis of variance with subdivided parcel (p<0.05). Results: Fixation Systems: Among the cementation techniques in the middle third, ASR showed the highest bond strength with statistical difference from the CEP, CFP and UNC systems. Only CFP presented statistically significant difference between the roots thirds, with the lower result in the apical third compared with the cervical third. In the other groups there was no significant difference among the different root thirds. In the cervical third, the lowest mean was obtained by SBR presenting statistically significant difference from ASR. Nanoleakage: In the apical third CFP presented the greatest nanoleakage with statistically significant difference from the middle and cervical thirds, and also from the other systems. Chlorhexidine: The use of chlorhexidine as root canal irrigant solution significantly reduced the bond strength of the self-adhesive cements. There was nanoleakage at the adhesive interface and hybrid layer formation was not observed, in all groups. Conclusions: The use of adhesive systems that use previous acid etching and are chemical setting enables better adhesive bond strength and better hybrid layer quality to be obtained. The use of chemical activator for the self-etching system allowed a significant improvement of the bond in the deepest region of the root. Prior root canal irrigation with 2% chlorhexidine negatively influenced the bond strength of self-adhesive cements / Doutorado / Dentística / Doutor em Clínica Odontológica
44

Effect of pre-etching to enamel and dentin on bond strength and interfacial morphology of different adhesives systems = Efeito do pré-condicionamento ácido do esmalte da dentina na resistência de união e morfologia de interface de diferentes sistemas adesivos / Efeito do pré-condicionamento ácido do esmalte da dentina na resistência de união e morfologia de interface de diferentes sistemas adesivos

Freitas, Marcela Santiago, 1987- 21 August 2018 (has links)
Orientadores: Mirela Sanae Shinohara, Mário Fernando de Góes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-21T23:51:52Z (GMT). No. of bitstreams: 1 Freitas_MarcelaSantiago_M.pdf: 38797129 bytes, checksum: 16869befa66eba198d1cb13ad5c9ac1d (MD5) Previous issue date: 2013 / Resumo: Estudos mostram que a resistência de união (RU) alcançada pelos sistemas adesivos autocondicionantes em superfície de esmalte pré-condicionado é significativamente maior se comparada aos valores obtidos em esmalte não condicionado. A partir destas evidências, este estudo teve como objetivo avaliar a RU e a morfologia da interface adesiva (MI) em esmalte e dentina de um adesivo autocondicionante de passo único multi-mode e um adesivo autocondicionante de dois passos com e sem pré-condicionamento ácido da superfície comparado a dois sistemas adesivos de condicionamento total, de dois e três passos. Terceiros molares humanos recém-extraídos foram seccionados para obtenção de superfícies planas em esmalte e dentina, as quais foram desgastadas com lixa SiC #600 para padronização da smear layer. Estas amostras foram divididas aleatoriamente em 6 grupos: (SBU) Scotchbond Universal; (SBUcond) SBU précondicionado; (CSE) Clearfil SE Bond; (CSEcond) CSE pré-condicionado; (SBMP) Scotchbond Multi-Purpose; e (EX) Excite F. Os grupos de condicionamento total e os autocondicionantes a serem avaliados com pré-condicionamento receberam a aplicação do ácido fosfórico por 15s em dentina e 30s em esmalte. Todos os sistemas adesivos foram aplicados de acordo com as recomendações dos fabricantes. Em seguida, um bloco de resina composta (Filtek Supreme Plus) foi construído incrementalmente sobre cada superfície preparada para o teste de RU, e para a MI, as superfícies foram restauradas com resina flow (Filtek Z-350 Flowable Restorative) formando um "sanduíche", de esmalte ou dentina. Após 24h, para avaliação da RU, as amostras foram seccionadas em palitos com área transversal de 0,8mm2 e submetidos ao teste de microtração com velocidade de 1,0mm/min. Os resultados foram analisados estatisticamente pelos testes one-way ANOVA e Fisher's PLSD (?=0.05) e os padrões de fratura analisados em Microscopia Eletrônica de Varredura (MEV). Para análise da MI, duas amostras de cada grupo foram incluídas em resina epóxica, polidas e observadas em MEV. Para esmalte, os resultados de RU mostraram que o SBUcond e CSEcond obtiveram os maiores valores, seguidos dos grupos SBMP, SBU e CSE que não apresentaram diferenças entre si. O grupo EX obteve os menores valores comparados aos outros grupos. Na análise da MI, os grupos SBUcond e CSEcond apresentaram nítidas extensões do adesivo penetrado no esmalte desmineralizado, semelhante aos sistemas de condicionamento total. Já para dentina, os resultados de RU mostraram que o condicionamento ácido prévio diminuiu significativamente os valores de RU dos sistemas autocondicionantes. Os maiores valores foram obtidos pelo SBU, CSE e SBMP, com valores de RU estatisticamente equivalentes entre si. Como em esmalte, o sistema adesivo EX obteve os menores valores. A análise em MEV da MI mostrou que o condicionamento prévio da dentina com adesivos autocondicionantes forma uma camada híbrida mais espessa com formação de tags resinosos, semelhantes aos sistemas adesivos de condicionamento total. Pode-se concluir que em esmalte, o condicionamento prévio aumentou significativamente os valores de RU para os sistemas autocondicionantes. Contudo, estes sistemas adesivos não apresentaram diferença estatística do adesivo convencional SBMP. E para dentina, o pré-condicionamento dos adesivos autocondicionantes diminuiu significativamente os valores de RU, entretanto, os valores de SBUcond não foram diferentes significativamente dos obtidos pelo sistema adesivo convencional SBMP / Abstract: Studies show that the bond strength (BS) achieved by self-etching adhesive systems on pre-etched enamel surface is significantly higher compared with the values obtained on unetched enamel. From this evidence, this study aimed to assess the BS and morphology of the adhesive interface (AI) on enamel and dentin of a one-step self-etching adhesive multi-mode and a two-step selfetching adhesive with and without pre-etching of surface compared with two totaletching adhesive systems, two and three steps. Recently extracted human third molars were sectioned to obtain flat surfaces in enamel and dentin, which were ground with #600 SiC sandpaper to standardize the smear layer. These samples were randomly assigned into 6 groups: (SBU) Scotchbond Universal; (SBU-et) SBU pre-etched; (CSE), Clearfil SE Bond, (CSE-et) CSE pre-etched; (SBMP) Scotchbond Multi-Purpose, and (EX) Excite F. The groups total-etching and selfetching to be evaluated with pre-etching received the application of phosphoric acid for 15s in dentin and 30s in enamel. All adhesive systems were applied according to manufacturers' recommendations. Then, a block of composite resin (Filtek Supreme Plus) was constructed incrementally on each surface prepared for BS testing. For AI, the areas were filled with flowable resin (Filtek Flowable Restorative Z-350) forming a "sandwich" of enamel or dentin. After 24 hours, to review the BS, the specimens were sectioned into sticks with cross-sectional area of 0.8mm² and submitted to microtensile test at a speed of 1.0mm/min. The results were statistically analyzed by one-way ANOVA test and Fisher's PLSD (?=0.05) and fracture patterns were analyzed through Scanning Electron Microscopy (SEM). For analysis of AI, two samples from each group were embedded in epoxy resin, polished and observed through SEM. For enamel, the results of BS showed that SBU-et and CSE-et obtained the highest values, followed by SBMP groups, SBU and CSE with no differences among them. The EX group obtained the lowest values of all other groups. In the analysis of AI, and CSE-et and SBU-et groups showed sharp tag extensions of the adhesive penetrated in the demineralized enamel, similar to total-etching systems. As for dentin, BS results showed that acid etching significantly reduced the BS values of self-etching systems. The highest values were obtained by the SBU, CSE and SBMP with BS values statistically equivalent to each other. As in enamel, the adhesive system EX obtained the lowest values. SEM analysis showed that BS for pre-etched dentin with selfetching adhesive forms a thicker hybrid layer with resin tags formation, similar to total-etching adhesive systems. It can be concluded that on enamel, the preetching significantly increased BS for self-etching systems. However, these adhesive systems showed no statistical difference from conventional adhesive SBMP. And to dentin, pre-etching of sel-etching adhesives significantly reduced BS, however, SBU-et values were not significantly different from those obtained by the conventional adhesive system SBMP / Mestrado / Dentística / Mestra em Materiais Dentários
45

Propriedades mecanicas de resinas acrilicas para base de protese antes e apos metodos de reparos / Mechanical properties of denture base acrylic resins before and after repair methods

Faot, Fernanda 11 October 2006 (has links)
Orientadores: Renata Cunha Matheus Rodrigues Garcia, Altair Antoninha Del Bel Cury / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-07T23:27:29Z (GMT). No. of bitstreams: 1 Faot_Fernanda_D.pdf: 1972781 bytes, checksum: b3ce58297c07d4abe90d5b2bf79729e7 (MD5) Previous issue date: 2006 / Resumo: Fraturas por impacto e flexão ainda são os principais problemas relatados tanto pelos portadores de próteses removíveis como pelos cirurgiões dentistas. Na tentativa de solucionar esse problema, alterações na composição química das resinas acrílicas como a inclusão de co-polímeros, adição de agente de ligação cruzada e a incorporação de partículas de borracha na forma de butadieno estireno têm sido propostas. Entretanto, poucos estudos avaliaram a incorporação destes aditivos modificadores de impacto no processo de fratura, deformação e microestrutura de resinas acrílicas. Além disso, devido à fragilidade dos materiais poliméricos a presença de trincas e fraturas em base de próteses removíveis ainda é alta e reparos são procedimentos comuns tanto por métodos diretos ou indiretos. Entretanto, as propriedades mecânicas de resinas acrílicas reparadas ainda não estão claramente descritas. Assim, os objetivos do presente trabalho foram: I) avaliar a resistência ao impacto e a flexão, bem como tensão de ruptura, módulo Young e deslocamento de escoamento de resinas acrílicas contendo modificadores de impacto e analisar sua microestrutura; II) determinar a resistência ao impacto e flexão de resinas acrílicas para base de prótese previamente fraturadas e reparadas com resinas fotopolimerizável, autopolimerizável e termopolimerizável. Como resultado, observou-se que a resina contendo borracha considerada de alto impacto, demonstrou alta capacidade de dissipação de energia, absorção de tensão e baixo percentual de deformação; entretanto exibiu processo de fratura frágil. Com relação às resinas utilizadas para reparo, concluiu-se que reparos realizados com a mesma resina usada para confecção dos corpos-de-prova, apresentaram melhores resultados quanto à resistência mecânica / Abstract: Fractures by impact and flexural action are the main problems described by denture users and dentists. Attempting to solve this problem, modifications on the chemical composition of the acrylic resins as co-polymer inclusion, cross linking agents addition and rubber particles incorporation in the form of butadiene styrene have been described as effective and worthwhile means to improve the impact strength and fracture propagation. However, literature lacks information regarding the incorporation of these modifying impact additives in the fracture process, plastic deformation and microstructure of acrylic resins. Furthermore, due to the brittleness of the polymeric materials, the presence of cracks and fractures in the removable prosthesis denture bases still remains high. Thus, frequent repairs are somewhat common procedures in the clinical practice, being by direct or indirect methods. Therefore, the effect of the repairs materials on the mechanical properties of acrylic resins is not clearly described yet. Front of these considerations, the purposes of the present study were: I) evaluate the impact and flexural strength, as well as, stress at yield, Young modulus and displacement at yield of acrylic resins containing impact modifiers and analyze their microstructure; II) determine the impact and flexural strength of denture base acrylic resins previously fractured and repaired with visible-light, auto and heat-polymerized acrylic resins. As results, it could be observed that the acrylic resin containing rubber particles, considered as the high impact, showed high capacity of energy dissipation and stress absorption before the fracture, lower percentage of deformation, however it exhibited brittle fracture process. Regarding to acrylic resins used as repair materials, it was concluded that repairs performed with the same resin used to fabricate the specimens showed the best results for mechanical resistance / Doutorado / Protese Dental / Doutor em Clínica Odontológica
46

Localised Corrosion of Austenitic Stainless Steels

Jha, Gyanendra Kumar 08 1900 (has links)
The localised corrosion behaviour of various grades of Austenitic Stainless Steels has been demonstrated by optical and electron microscopy. The effect of sensitisation upon subsequent corrosive attack has been investigated. A theoretical model based upon thermodynamic and kinetic considerations has been proposed to account for the observed experimental results. / Thesis / Master of Engineering (ME)
47

Growth and characterisation of CN films incorporating fullerene-like species

Alexandrou, Ioannis G. January 1999 (has links)
No description available.
48

"Imunoglobulina na patogenia da leishmaniose visceral em hamsteres" / Immunoglobulin in the pathogenesis in visceral leishmaniasis in hamsters

Mathias, Regiane 21 January 2005 (has links)
A patogênese das lesões teciduais na leishmaniose visceral (LV) foi pesquisada em hamsteres infectados com amastigotas de Leishmania (Leishmania.) chagasi. Foi observada a internalização de IgG de hamsteres com LV por células endoteliais da veia umbilical humana in vitro e no fígado e rim, sob microscopia eletrônica de transmissão aos 30 e 60 dias de infecção. Também foi observado o aumento na permeabilidade vascular aos 60 dias de infecção e a IgG purificada de hamsteres com LV induziu aumento na permeabilidade em hamsteres normais. Os resultados sugerem a internalização de IgG por células endoteliais como um mecanismo alternativo envolvido na patogênese das lesões teciduais em LV. / Pathogenesis of tissue lesions in visceral leishmaniasis (VL) was searched in hamsters infected with Leishmania (Leishmania) chagasi amastigotes. Internalization of IgG from VL hamsters by human umbilical vein endothelial cells was observed in vitro and in liver and kidney in hamsters VL, under transmission electron microscopy, at 30 and 60 days of infection. Increased vascular permeability was observed at 60 days of infection in VL hamsters, and purified IgG from VL hamsters induced permeability increase in normal hamsters. These data suggest the internalization of IgG by endothelial cells as an alternative mechanism involved in the pathogenesis of tissue lesions in VL.
49

Estudo comparativo in vitro das estruturas orgânicas e inorgânicas da dentina saudável e esclerosada humana e bovina: nanodureza, concentração de Ca e P e análise morfológica / In vitro comparative study of organic and inorganic components analysis of health and sclerotic human and bovine dentin: nanohardness, Ca and P concentration and morphological analysis

Castanho, Gisela Muassab 03 December 2010 (has links)
A dentina esclerosada é um substrato comumente encontrado em pacientes idosos. No entanto, existem poucos estudos comparativos entre dentina humana e bovina esclerosadas. O objetivo deste estudo foi comparar os componentes inorgânicos e orgânicos da dentina saudável e esclerosada humana e bovina, através de cinco parâmetros: nanodureza, módulo de elasticidade, análise quantitativa da concentração de Cálcio (Ca) e Fósforo (P), densidade tubular e morfologia do colágeno. Trinta dentes humanos e 30 bovinos foram distribuídos em 4 grupos experimentais (n=15 por grupo): dentina humana saudável (DHS), esclerosada humana (DEH), bovina saudável (DBS), e bovina esclerosada (DBE). Os dentes saudáveis foram preparados na mesma altura e inclinação dos dentes esclerosados expondo níveis similares da dentina e obtendo fragmentos com 2mm de espessura. Foram realizadas 3 medições por espécime em 3 áreas pré determinadas de dentina intertubular com a utilização do Nanoindentador (carga de 500N por 5 s). Cinco espécimes de cada grupo foram preparados para Microscopia Eletrônica de Varredura (MEV). Com o auxílio da Energia Dispersiva por Raios-X EDX foram obtidos os valores (em percentagem) das concentrações de Ca e P e calculada a relação Ca:P. A contagem dos túbulos por área foi realizada em todas as eletromicrografias. Após descalcificação e preparo, o restante dos espécimes foi analisado em Microscopia Eletrônica de Transmissão (MET). DBS obteve maiores valores de nanodureza comparada à DBE e DHS. DHE sem diferenças com DHS e DBE (p=0,0008). DBS exibiu maiores valores de módulo de elasticidade somente comparada à DHS (p=0,000). A análise estatística não demonstrou diferenças estatisticamente significantes (p=0,71) entre as concentrações de Ca e P. Quanto à densidade tubular (número de túbulos/mm²), os grupos saudáveis foram maiores que os esclerosados e os humanos maiores que os bovinos. As fibras colágenas da DBS mostraram-se mais compactadas e mais desorganizadas que as demais. Pôde se concluir que apenas as concentrações de Ca e P foram similares e que as dentinas esclerosadas humana e bovina mostraram similaridade. Esta pesquisa teve suporte da Fapesp sob o número 2008/10290-8. / The sclerotic dentin has been commonly found in elderly patients. However, there are scarce reports in the literature comparing on the use of human and bovine sclerotic dentins. The objective of this study was to compare inorganic and organic components of healthy and sclerotic dentins from human and bovine. Five parameters were analyzed: nanohardness, elastic modulus, quantitative analysis of Calcium (Ca) and Phosphorous (P) concentrations, tubular density and ultrastructural morphology. Thirty human teeth plus 30 bovine teeth were distributed in 4 experimental groups (n=15 per group): human healthy dentin (HHD), human sclerotic dentin (HSD), bovine healthy dentin (BHD) and bovine sclerotic dentin (BSD). Healthy teeth were cut in the same level and inclination of the sclerotic superficial dentins. The nanohardness and elastic modulus (GPa) of three pre determined areas of each exposed dentin was measured using a nanoindenter (500N for 5s). Five samples of each group were prepared for scanning electron microscopy (SEM) examination. Energy Dispersive X-ray (EDX) was used for obtaining the Ca/P ratio. The tubular density was obtained by counting the tubules in scanning electron micrographs taken in the same magnification and work distance. Data were statistically analyzed by ANOVA complemented by the Tukeys test (p0.05). The ultrastructure of the dentins was observed in specimens processed for transmission electron microscopy (TEM). BHD exhibited significant higher nanohardness than BSD and HHD. HSD nanohardness was similar to those of HHD and BSD (p=0,0008). BHD exhibited significant higher elastic modulus than HHD (p=0,000). The Ca:P ratios were similar amongst all groups (p=0.71). The tubular densities were higher in the healthy dentins than in the sclerotic for both human and bovine. The human dentins presented higher tubular densities than bovine dentins (p=0.000). The intertubular dentin of BHD showed short collagen fibers distributed in a condensed fashion; whereas the other dentins exhibited well-organized long bundles of collagen fibers. It was concluded that sclerotic dentins of human and bovine share most morphological and structural characteristics. This research was supported by Fapesp grants number 2008/10290-8.
50

Molecular and structural investigation of assembly, maturation and heterogeneity of inner hair cell ribbon synapses

Michanski, Susann 15 October 2018 (has links)
No description available.

Page generated in 0.0725 seconds