• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 48
  • 29
  • 6
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 106
  • 106
  • 52
  • 50
  • 42
  • 34
  • 33
  • 11
  • 10
  • 10
  • 10
  • 8
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Atomic resolution microscopy using electron energy-loss spectroscopy

Witte, C. January 2008 (has links)
This thesis explores the theory of electron energy-loss spectroscopy (EELS) in atomic resolution electron microscopy. / The first unequivocal evidence of the effective nonlocal potential in momentum-transfer-resolved EELS is presented. For suitable geometries, the nonlocal potential can be well approximated by a local potential. In scanning transmission electron microscopy (STEM) the validity of this is mainly influenced by the detector size and, contrary to conventional wisdom, a thin annular detector does not allow direct image interpretation. It is found that the best way to ensure the potential is well approximated by a local potential is to use a detector with a large collection angle. / To simplify computation and interpretation it is desirable to make the single-channelling approximation. In this approximation only the elastic scattering of the probe before the ionisation event is modelled. It is shown how this approximation breaks down for the small detectors used in momentum-transfer-resolved EELS and this is confirmed with experimental results. Double-channelling calculations, where the channelling of the probe both before and after the ionisation event are modelled, can also be simulated. An alternative approximation for small detectors that includes double channelling and is more applicable for momentum-transfer-resolved EELS is also presented. / Beyond chemical information, the fine structure of an absorption edge gives bonding and electronic information. Incorporating fine structure into channelling theory allows the exploration of the effects of channelling on fine structure. The weighting of the two different spectra in graphite, as a function of incident probe tilt in momentum-transfer-resolved EELS, is calculated using double-channelling simulations. This is combined with experimental data and multivariate statistical analysis to extract the two physical spectra, greatly simplifying the analysis of a large data set. / The effect of the nonlocal potential and channelling on site-specific electronic structure analysis by channelling EELS is examined. It is found that using a large on-axis detector can make the interaction effectively local, leading to a greater change in the spectra as a function of sample tilt. Alternatively offsetting the detector can achieve similar results but at the cost of greater statistical noise. Channelling calculations were combined with the program FEFF and the full energy differential cross section was calculated from first principles for the aluminium K edge as a function of sample tilt in nickel aluminate spinel. Qualitative agreement with experiment was found but quantitative agreement will require further investigation. / The theory of fine structure in STEM was examined, using strontium titanate to see how the high spatial resolution of STEM can be used in conjunction with energy-loss near-edge spectroscopy measurements. The possibility of imaging unoccupied electron molecular orbitals using STEM was also examined.
32

Calcium aluminate cement as dental restorative : mechanical properties and clinical durability /

Sunnegårdh-Grönberg, Karin, January 2004 (has links)
Diss. (sammanfattning) Umeå : Univ., 2004. / Härtill 5 uppsatser.
33

Dopamine-dependent plasticity and subcellular locations of dopamine D1 receptors : in relation to glutamate NMDA receptors and endogenous opioids in the nucleus accumbens, implications for schizophrenia /

Hara, Yuko. January 2008 (has links)
Thesis (Ph. D.)--Cornell University, May, 2008. / Vita. Includes bibliographical references (leaves 143-165).
34

Avaliação da influência da técnica de fotopolimerização da resina composta e diferentes materiais protetores pulpares na formação de fendas /

Souza, Niélli Caetano de. January 2007 (has links)
Resumo: O objetivo deste estudo foi avaliar a influência da fotopolimerização gradual no deslocamento de materiais protetores pulpares em função da contração de polimerização da resina composta através da formação de microfendas nas interfaces: estrutura dental/material protetor pulpar/ resina composta. Cavidades classe V, com dimensões padronizadas foram preparadas nas faces V e L de 20 terceiros molares humanos, divididos em 4 grupos de acordo com o material protetor pulpar e técnica de fotopolimerização: (1) Ketac Molar Easymix, 3M ESPE - (IVQ) + Fotopolimerização convencional - 850mW/cmø por 20s (FC); (2) IVQ + Fotopolimerização gradual - 100 mW/cm2 até 1000 mW/cm2 por 10s e 1000 mW/cm2 por 10s (FG); (3) Vitrebond 3M ESPE (IVR) + FC; (4) IVR +FG. Todas as cavidades foram restauradas com sistema adesivo Single Bond (3M ESPE) e resina composta híbrida Four Seasons (Ivoclar Vivadent). O aparelho fotopolimerizador utizado foi Optilux 501 (Demetron - Kerr) no modo convenciona e gradual (RAMP). Após ciclagem térmica um segmento longitudinal de 2 mm de espessura foi obtido na porção central de cada restauração e, em seguida, submetidos às etapas de fixação e desidratação em grau ascendente de etanol. A adaptação interna dos materiais à parede axial foi analisada em MEV, com 1000x de magnificação. A análise estatística realizada pela ANOVA a dois critérios de avaliação e pelos testes de Levene e Shapiro-Wilk (p_0,05) mostrou haver significância estatística entre as técnicas de fotopolimerização convencional e gradual (Ramp). Há evidência de que a fotopolimerização convencional produz, em 13 média, fendas maiores do que a fotopolimerização gradual. / Abstract: The aim of this study was to evaluate the influence of gradual photolymerization on the displacement of pulp protective materials due to the resinþs photopolymerization contraction trough the formation of gaps on the following interfaces: dental structure/ pulp protective material/ composite resin. Class V cavities with standardized dimensions were prepared on the buccal and lingual surfaces of 20 human sound third molars, divided into 4 groups according to their pulp protective material and photopolymerization technique:(1) Ketac Molar Easymix, 3M ESPE- (IVQ) + Conventional photopolymerization-850 mW/cm2 for 20 seconds (FC); (2) IVQ + gradual photopolymerization-100 mW/cm2 to 1000 mW/CM2 for 10 seconds and 1000 Mw/CM2 for 10 seconds (FG); (3) Vitrebond 3M ESPE (IVR)+ FC; (4) IVR + FG.All cavities were restored using the adhesive system Single Bond (3M ESPE) and hybrid composite resin Four Seasons (Ivoclar Vivadent). The device used for photopolymerization was the Optilux 501 (Demetron-Kerr) in both conventional and gradual (RAMP) modes. After thermal cycling, a longitudinal segment of 2 mm of thickness was obtained from the central part of every restoration, and submitted to fixation and dehydration with uprising levels of ethanol processes. The internal adaptation of the materials to the axial wall of the preparation was analyzed in 16 SEM with 1,000x of magnification. The statistical analysis was made using two-way ANOVA and Levene and Shapiro-Wilk (p _ 0,05) tests. Results showed statistically significant differences between the gradual (RAMP) and conventional photopolymerization techniques. There are evidences that the conventional technique creates wider gaps than the gradual technique. / Orientador: Alexandre Henrique Susin / Coorientador: Osmir Batista de Oliveira Junior / Banca: Marcelo Ferrarezi de Andrade / Banca: Roselaine Terezinha Pozzobon / Doutor
35

Avaliação da influência da técnica de fotopolimerização da resina composta e diferentes materiais protetores pulpares na formação de fendas

Souza, Niélli Caetano de [UNESP] 01 February 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-02-01Bitstream added on 2014-06-13T21:02:28Z : No. of bitstreams: 1 souza_nc_me_arafo.pdf: 1115015 bytes, checksum: 8487455e45f6d12782f7b081be948890 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar a influência da fotopolimerização gradual no deslocamento de materiais protetores pulpares em função da contração de polimerização da resina composta através da formação de microfendas nas interfaces: estrutura dental/material protetor pulpar/ resina composta. Cavidades classe V, com dimensões padronizadas foram preparadas nas faces V e L de 20 terceiros molares humanos, divididos em 4 grupos de acordo com o material protetor pulpar e técnica de fotopolimerização: (1) Ketac Molar Easymix, 3M ESPE - (IVQ) + Fotopolimerização convencional - 850mW/cmø por 20s (FC); (2) IVQ + Fotopolimerização gradual - 100 mW/cm2 até 1000 mW/cm2 por 10s e 1000 mW/cm2 por 10s (FG); (3) Vitrebond 3M ESPE (IVR) + FC; (4) IVR +FG. Todas as cavidades foram restauradas com sistema adesivo Single Bond (3M ESPE) e resina composta híbrida Four Seasons (Ivoclar Vivadent). O aparelho fotopolimerizador utizado foi Optilux 501 (Demetron - Kerr) no modo convenciona e gradual (RAMP). Após ciclagem térmica um segmento longitudinal de 2 mm de espessura foi obtido na porção central de cada restauração e, em seguida, submetidos às etapas de fixação e desidratação em grau ascendente de etanol. A adaptação interna dos materiais à parede axial foi analisada em MEV, com 1000x de magnificação. A análise estatística realizada pela ANOVA a dois critérios de avaliação e pelos testes de Levene e Shapiro-Wilk (p_0,05) mostrou haver significância estatística entre as técnicas de fotopolimerização convencional e gradual (Ramp). Há evidência de que a fotopolimerização convencional produz, em 13 média, fendas maiores do que a fotopolimerização gradual. / The aim of this study was to evaluate the influence of gradual photolymerization on the displacement of pulp protective materials due to the resinþs photopolymerization contraction trough the formation of gaps on the following interfaces: dental structure/ pulp protective material/ composite resin. Class V cavities with standardized dimensions were prepared on the buccal and lingual surfaces of 20 human sound third molars, divided into 4 groups according to their pulp protective material and photopolymerization technique:(1) Ketac Molar Easymix, 3M ESPE- (IVQ) + Conventional photopolymerization-850 mW/cm2 for 20 seconds (FC); (2) IVQ + gradual photopolymerization-100 mW/cm2 to 1000 mW/CM2 for 10 seconds and 1000 Mw/CM2 for 10 seconds (FG); (3) Vitrebond 3M ESPE (IVR)+ FC; (4) IVR + FG.All cavities were restored using the adhesive system Single Bond (3M ESPE) and hybrid composite resin Four Seasons (Ivoclar Vivadent). The device used for photopolymerization was the Optilux 501 (Demetron-Kerr) in both conventional and gradual (RAMP) modes. After thermal cycling, a longitudinal segment of 2 mm of thickness was obtained from the central part of every restoration, and submitted to fixation and dehydration with uprising levels of ethanol processes. The internal adaptation of the materials to the axial wall of the preparation was analyzed in 16 SEM with 1,000x of magnification. The statistical analysis was made using two-way ANOVA and Levene and Shapiro-Wilk (p _ 0,05) tests. Results showed statistically significant differences between the gradual (RAMP) and conventional photopolymerization techniques. There are evidences that the conventional technique creates wider gaps than the gradual technique.
36

Estudo in vitro da eficácia do gel de EDTA 24% na remoção de smear layer e exposição de fibras colágenas da superfície radicular

Sousa, Cliciane Portela [UNESP] 25 October 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:28Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-10-25Bitstream added on 2014-06-13T19:23:25Z : No. of bitstreams: 1 sousa_cp_dr_arafo.pdf: 5847108 bytes, checksum: 8609ccee8f066df3a78ac161f5a2a8ba (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo do presente estudo foi avaliar, por meio da Microscopia Eletrônica de Varredura (MEV), a eficácia do condicionamento químico com o gel de EDTA 24% na remoção de smear layer e exposição de fibras colágenas, avaliando-se diferentes marcas comerciais, modos e tempos de aplicação. Dentes humanos extraídos foram desgastados com fresa diamantada para remoção do cemento e raspados com curetas de Gracey 5-6 para formação de smear layer. Após o seccionamento dentário, as 225 amostras obtidas foram divididas em 5 grupos: I) Soro Fisiológico; II) EDTA 24% (Farmácia Santa Paula); III) EDTA-T 24% (Farmácia Santa Paula); IV) EDTA 24% (Biora); V) EDTA 24% (Biodinâmica). As amostras de cada grupo(n=45) foram divididas em subgrupos (n= 5) e condicionadas nos tempos de 01, 02, 03 minutos e nos modos de aplicação passiva, ativa vigorosa (fricção) e ativa suave (pincel). Após a análise em MEV, as fotomicrografias foram avaliadas um examinador calibrado e cego. A análise estatística (Teste de Kruskal-Wallis e Dunn), revelou que o gel de EDTA 24% da Biodinâmica promoveu inferior remoção smear layer em relação aos outros agentes testados. Não houve diferenças estatísticas para os tempos de aplicação. O modo de aplicação ativa suave (pincel) resultou em menor quantidade de smear layer residual. Conclui-se que as comerciais testadas do gel de EDTA 24% foram eficientes na remoção de smear layer e exposição de fibras colágenas, nos modos de aplicação ativa vigorosa (fricção) e ativa suave (pincel), independentes do tempo de aplicação. No entanto, a marca comercial Biodinâmica promoveu inferior remoção de smear layer e exposição de fibras colágenas em relação às outras marcas comerciais testadas. / The aim of this study was to evaluate in vitro the conditioning efficacy with 24% EDTA gel from different trade marks times and application ways using scanning electron microscope. Extracted human teeth were submitted to cementum removal by means of diamond bur in high rotation speed, followed by scaling and root planning with Gracey 5-6 curette in order to further smear layer formation. The 225 samples were randomly assigned to 5 groups: I) control (sterile saline application); II) 24% EDTA (Santa Paula Pharmacy); III) 24% EDTA -T (Santa Paula Pharmacy); IV) 24% EDTA (Biora); V) 24% EDTA (Biodynamic). For each experimental group the application times were 1, 2 or 3 minutes. Substances were applied in 3 different ways: a) topical application (cotton pellets laid passively on the samples); b) vigorous friction (cotton pellets were scrubbed against samples surface); c) smooth friction (using a brush on dentinal surface). One calibrated examiner analyzed the micrographs. The statistical analysis (Kruskal Wallis Test and Dunn Test) showed that 24% EDTA (Biodynamic) proved to be less effective than others agents, there were no statistical differences between times of application. We conclude that smooth friction (using a brush on dentinal surface) of 24% gel efficiently removed the smear layer and exposed dentin collagen matrix in al times of application. The exception was the Biodynamic gel that did not achieve this result.
37

Avaliação da superfície do esmalte dentário por microscopia eletrônica de varredura após a remoção do bráquete e polimento

Pignatta, Lilian Maria Brisque [UNESP] 13 December 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-12-13Bitstream added on 2014-06-13T18:56:44Z : No. of bitstreams: 1 pignatta_lmb_me_araca.pdf: 865487 bytes, checksum: 83bd33e9257f262b5aff8eb76ff91ac1 (MD5) / Fundação para o Desenvolvimento da UNESP (FUNDUNESP) / Introdução: a preservação da estrutura de esmalte após a remoção dos acessórios ortodônticos é uma obrigação do clínico. Portanto, procura-se um protocolo de descolagem com bases científicas. Objetivou-se neste trabalho avaliar por Microscopia Eletrônica de Varredura (MEV) a influência de quatro protocolos de remoção de bráquetes e polimento da superfície do esmalte e propor um protocolo que minimizasse os danos na superfície do esmalte. Material e método: doze incisivos permanentes bovinos foram divididos em quatro grupos de acordo com os instrumentos utilizados para a descolagem dos bráquetes e remoção do remanescente adesivo. Os bráquetes foram descolados com o alicate de descolagem reto (Ormco Corp.) nos grupos 1 e 2, e com o instrumento de descolagem Lift-Off (3M Unitek) nos grupos 3 e 4. Os remanescentes adesivos dos grupos 1 e 3 foram removidos com o alicate removedor de resina longo (Ormco Corp.) e dos grupos 2 e 4 com broca de carboneto de tungstênio (Beavers Dental) em alta-rotação com constante refrigeração de água. As superfícies, após cada etapa da descolagem e polimento, foram avaliadas em réplicas de resina epóxica e foram obtidas eletromicrografias com aumento de 50 e 200X em todos os grupos. Resultado: os quatro protocolos de remoção de acessórios ortodônticos e polimento ocasionaram irregularidades no esmalte. Conclusão: a remoção do bráquete com o alicate de descolagem reto, seguido da remoção do remanescente adesivo com broca de carboneto de tungstênio e polimento final com pasta de pedra-pomes foi o procedimento que ocasionou menores danos ao esmalte, sendo o protocolo sugerido para a remoção dos acessórios ortodônticos. / Introduction: the preservation of the enamel structure after the removal of the orthodontic accessories is an obligation of the clinical. Therefore, a protocol of debonding with scientific bases is searched. The aim of this work was to evaluate through Scanning Electronic Microscopy (SEM) the influence of four protocols of bracket s removal and polishing on the enamel and to recommend a protocol that minimized the damages to the enamel surface. Methods: twelve permanent bovine incisors were divided into four groups according to the instruments used to debond and remove of adhesive remnants. The brackets were removed with straight debonding pliers (Ormco Corp.) in the groups 1 and 2, and with Lift-Off debonding instrument (3M Unitek) in the Groups 3 and 4. The adhesive remnants in the groups 1 and 3 were removed with the adhesive removing pliers (Ormco Corp.) and in the groups 2 and 4 with high speed tungsten carbide bur with constant water refrigeration (Beavers Dental). The surfaces, after each step of debonding and polishing were evaluated in replicas of epoxy resin and were obtained electromicrographies with magnification of 50 and 200X in all groups. Results: the four removal protocols of orthodontic accessories and polishing caused irregularities to the enamel. Conclusion: the bracket s removal with straight debonding pliers, followed by the removal of the adhesive remnants with tungsten carbide bur and final polishing with pumice was the procedure that caused less damage to enamel, being the suggested protocol for removal of orthodontic accessories.
38

Avaliação do efeito do selenito de sódio em dentes de filhotes de ratas irradicadas / Evaluation of sodium selenite effect on offspring teeth of irradiated female rats

Neves, Ellen Gaby 02 April 2011 (has links)
Orientador: Solange Maria de Almeida / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T17:57:36Z (GMT). No. of bitstreams: 1 Neves_EllenGaby_D.pdf: 2307967 bytes, checksum: 400f999a308a849ab460792b22d1c0c8 (MD5) Previous issue date: 2011 / Resumo: O objetivo, neste trabalho, foi avaliar o efeito do selenito de sódio em molares de filhotes de ratas irradiadas. Foram utilizadas 20 ratas grávidas divididas aleatoriamente em quatro grupos experimentais: controle, selênio, irradiado e selênio irradiado. As ratas dos grupos irradiado e selênio irradiado receberam na região abdominal dose única de 4 Gy de radiação X, sendo que o momento da irradiação correspondeu a da fase de sino da odontogênese, 19º dia de gestação. Os animais dos grupos selênio e selênio irradiado receberam 0,3 mg/kg de selenito de sódio aos 18 dias de gestação e o grupo controle foi composto por animais que não receberam selenito de sódio e nem foram irradiados. Os filhotes foram sacrificados aos 3 e 4 dias de nascimento para a avaliação da birrefringência da matriz orgânica do esmalte com o auxílio do microscópio de polarização e aos 30 dias de idade para avaliação da dimensão intercuspídea dos molares por meio da microscopia eletrônica de varredura. Os dados foram submetidos à análise de variância (p?0,05). Por meio da birrefringência, foi possível observar os efeitos deletérios da radiação, uma vez que os grupos irradiados diferiram estatisticamente dos grupos não irradiados, em todos os tempos de estudo. Porém, não houve diferença estatística entre os grupos selênio irradiado e irradiado. Foi observado também diferença estatística entre os grupos controle e selênio no tempo de 4 dias, demonstrando a toxicidade do selenito para esse tempo de estudo. A análise das distâncias intercuspídeas dos molares demonstrou atraso no desenvolvimento desses dentes, sendo observada diferença estatística entre os grupos controle e irradiado, nas medidas lineares mésio-distal, vestíbulo-lingual mesial e vestíbulo-lingual central dos dentes superiores e vestíbulo-lingual distal dos dentes inferiores. Entre os grupos selênio irradiado e irradiado, não foi observada diferença estatística nos dentes inferiores e entre o grupo controle e selênio não houve diferença estatística em nenhuma das medidas realizadas. Baseado nesses resultados pôde-se concluir que o selenito de sódio não teve ação radioprotetora e teve efeito tóxico nos tempos iniciais em molares de filhotes de ratas irradiadas durante a odontogênese. / Abstract: The aim of this study was to evaluate the sodium selenite effect on offspring molars of irradiated female rats. For this purpose, twenty pregnant female rats were used and divided into four experimental groups: control, selenium, irradiated and selenium-irradiated. The animals of the irradiated and selenium-irradiated groups received a single exposure dose of 4 Gy of X rays in the abdominal region, at this moment the molar is in the bell stage of odontogenesis, 19º gestation days. The animals of the selenium and selenium-irradiated group received 0,3 mg/kg of sodium selenite (i.p) at eighteen days of pregnancy and the animals of the control group did not received neither sodium selenite nor irradiation. The pups were sacrificed at 3 and 4 days of birth for the organic enamel matrix birefringence evaluation using a polarizing microscope and at 30 days of birth for assessment of the molar intercuspal size by scanning electron microscopy. Data were submitted to statistical analysis ANOVA (p?0,05). It was possible to observe, by the birrefringence, the deleterious effects of radiation. There was a statistically significant difference between the irradiated groups and no irradiated groups on all times of the study. By the way, there was not a statistically significant difference between selenium-irradiated and irradiated groups. It was also observed statistically significant difference between control and selenium groups in the fourth day, showing the selenium toxicity. The analysis of molars intercuspal distances presented a delayed development, with statistical difference between control and irradiated groups. In the linear measurements mesiodistal, buccolingual mesial cusp and buccolingual center cusp of the upper teeth and buccolingual distal cusp of the lower teeth. Between the selenium-irradiated and irradiated groups there was no statistical difference of the lower teeth and between control and selenium groups there was no statistical difference in any of the measurements. Based on these results, it was possible to conclude that sodium selenite did not present a radioprotective effect and present a toxic effect on the initial times on offspring molars of irradiated female rats during odontogenesis. / Doutorado / Radiologia Odontologica / Doutor em Radiologia Odontológica
39

Protocolo de tratamento de superficie de pino de fibra de quartzo com H2O2 / Surface treatment protocol of fiber-glass with peroxide hidrogeny

Menezes, Murilo de Sousa 04 June 2009 (has links)
Orientador: Luis Roberto Marcondes Martins / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T12:27:27Z (GMT). No. of bitstreams: 1 Menezes_MurilodeSousa_D.pdf: 3933379 bytes, checksum: 5a242574b594d3fc29d4767d06e9d5cb (MD5) Previous issue date: 2009 / Resumo: O objetivo deste estudo foi avaliar a resistência de união entre pinos de fibra de quartzo e resina de preenchimento, preliminarmente em função do uso do silano isoladamente e silano associado ao adesivo. Em seguida, em função do condicionamento de superfície do pino com peróxido de hidrogênio (H2O2), variando a concentração (24 e 50%) e o tempo de aplicação (1, 5 e 10 min). Propôs-se também, avaliar qualitativamente, por meio de Microscopia Eletrônica de Varredura (MEV), a morfologia de superfície dos pinos tratados com H2O2 em diferentes protocolos de aplicação, comparativamente ao pino sem nenhum tratamento de superfície. Para avaliar a resistência de união 80 pinos de fibra de quartzo (AESTHETI-PLUS, Bisco) foram divididos, aleatoriamente, em oito grupos (n=10): inicialmente, foram testados (G1) tratado apenas com silano e (G2) tratado com silano e adesivo, para definição do grupo controle. Os grupos experimentais (G3) tratado com H2O2 a 24% por 1 min; (G4), H2O2 a 24% por 5 min; (G5), H2O2 a 24% por 10 min; (G6), H2O2 a 50% por 1min; (G7), H2O2 a 50% por 5 min e (G8), H2O2 a 50% por 10 min. Em seguida, todos os grupos experimentais receberam aplicação de uma camada de silano (PORCELAIN PRIMER, Bisco) e outra de adesivo (ALL BOND 2, Bisco). Em seguida as restaurações em resina composta (CORE-FLO, Bisco) foram simuladas utilizando moldes de silicones. Após 24h de armazenagem em água a 37ºC, as amostras foram submetidas a cortes seriados, perpendiculares ao longo eixo do pino, obtendo amostras com dimensões de aproximadamente 1x1mm, com formato de palito e constituída por resina/pino/resina. As amostras foram submetidas ao ensaio mecânico de microtração à velocidade de 0,5 mm/min até o rompimento dos espécimes. Para análise em MEV, 14 pinos foram divididos em sete grupos (n=2): G1 (controle) sem tratamento nenhum; e os outros seis grupos receberam o mesmo tratamento de superfície com H2O2 correspondente as amostras do ensaio de microtração, entretanto, sem aplicação de silano e adesivo. Os dados de resistência de união apresentaram distribuição normal e homogênea e foram submetidos ao teste t-Student para comparar o grupo G1 ao G2. Os resultados mostraram que G2 apresentou valor de resistência de união significantemente superior ao G1, sendo então considerado como controle para posterior comparação aos grupos experimentais. Em seguida, para comparar entre si os grupos tratados com H2O2, foi aplicada análise de variância fatorial ANOVA (3x2). Foi também realizado Post Hoc Tests Dunnett, para comparação do grupo controle (G2) aos grupos experimentais (tratados com H2O2) em análise de fator único. Os resultados demonstraram que os grupos experimentais apresentaram valores de resistência de união semelhantes entre si e superiores ao controle (G2). As imagens de MEV demonstraram que o tratamento de superfície com H2O2 remove parcialmente a resina epóxica dos pinos expondo as fibras de quartzo. Conclui-se que o H2O2 altera a morfologia de superfície dos pinos de fibra de vidro e aumenta a resistência de união entre o pino e resina de preenchimento. / Abstract: Coupling of fiber posts to composites is hampered by absence of chemical union between epoxy-based resins. This study analyzed the effect of surface treatments of glass fiber posts on bond strength to resin cores. A total of 94 fiber posts (AESTHETI-PLUS, Bisco) were randomly divided into eight groups, according to the surface pre-treatments performed (n=10): (G1), silanization; (G2), silanization and adhesive. Six experimental groups: (G3) 24% hydrogen peroxide (H2O2) for 1 min; (G4), 24% H2O2 for 5 min; (G5), 24%H2O2 for 10 min; (G6), 50% H2O2 for 1min; (G7), 50% H2O2 for 5 min and (G8), 50% H2O2 for 10 min. This was followed by silanization (PORCELAIN PRIMER, Bisco) of the exposed quartz fiber to enhanced their chemical bonding to core composite and application of bonding agent (ALL BOND 2, Bisco). Two posts of each experimental group and two posts without the treatment were investigating the morphologic aspect surface post. The composite resin (CORE-FLO, Bisco) was used for the core build-up in ten remaining posts of each group. The samples were cut so as to obtain microtensile sticks that were loaded in tension at cross-heat speed of 0,5mm/min until failure. Data were statistically analyzed. SEM examination showed pretreatment with H2O2 modifying the fiber post surface. The post-core strengths achieved in G2 were significantly higher, that G1. The experimental groups G3, G4, G5, G6, G7 and G8 were similar and significantly higher, that G2. In conclusion the adhesive and silane enhanced the interfacial strength between them and core material. The hydrogen peroxide modified the surface morphology of fiber post and also significantly enhanced the interfacial strength between them and core material. / Doutorado / Dentística / Doutor em Clínica Odontológica
40

Efeito do condicionamento acido do esmalte na adptação marginal 'in vivo' de restaurações indiretas em resina composta cimentadas com material autoadesivo / The effect of enamel etching on the 'in vivo' marginal adaptation of indirect composite resin restorations luted with a self-adhesive material

Sartori, Cristiana Godoy, 1967- 13 August 2018 (has links)
Orientador: Mario Fernando de Goes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T22:52:00Z (GMT). No. of bitstreams: 1 Sartori_CristianaGodoy_M.pdf: 5052776 bytes, checksum: d305b8dc296a1c6feb6d207ea417904d (MD5) Previous issue date: 2009 / Resumo: Estudos in vitro tem sugerido o condicionamento ácido do esmalte antes da cimentação de restaurações indiretas com o cimento autoadesivo RelyX Unicem. Entretanto, não existe comprovação científica de que este procedimento tenha alguma relevância clínica. O objetivo deste estudo in vivo, foi avaliar o efeito do condicionamento ácido do esmalte na qualidade marginal de restaurações indiretas, tipo inlay/onlay de resina composta, utilizando o cimento autoadesivo RelyX U100. Foram selecionados 42 dentes posteriores de 25 pacientes que apresentaram 1 ou 2 dentes com restaurações extensas insatisfatórias, necessitando substituição. Os dentes foram preparados para receberem restaurações indiretas do tipo inlay/onlay. Imediatamente após o preparo cavitário, os dentes foram moldados com silicone polimerizado por adição e protegidos com material temporário. As restaurações em resina composta foram confeccionadas sobre troqueis de gesso de acordo com a técnica por camadas. O tempo de fotoativação foi de 40s para opacidade dentina e 20s para as demais, utilizando um aparelho de luz emitida por diodo (LED). Uma semana depois, os pacientes retornaram para cimentação das restaurações indiretas. Os dentes foram isolados com lençol de borracha e as restaurações foram cimentadas aleatoriamente de acordo com um dos protocolos: Grupo condicionado - condicionamento ácido do esmalte + cimento autoadesivo; Grupo não condicionado - cimento autoadesivo. As restaurações foram mantidas sob pressão por 2 minutos, enquanto se procedia à remoção dos excessos de cimento, e em seguida foram fotoativadas por 60s em cada face. O acompanhamento clínico foi realizado 1 semana (início) e 12 meses após a cimentação, quando os dentes foram fotografados, moldados e avaliados conforme escores pré-estabelecidos (critério USPHS). Réplicas em resina epóxica foram examinadas em microscopia eletrônica de varredura (MEV) com aumentos de 18X a 200X. Os resultados foram calculados em porcentagem do comprimento total da margem visível para cada parâmetro. Não houve diferença estatística entre os grupos, com exceção da característica 'fratura marginal da restauração' na avaliação em MEV, para o grupo não condicionado. O tempo contribuiu significativamente para a degradação das margens sendo que a presença de underfilling de cimento foi a característica mais frequente. Concluiu-se que, o condicionamento ácido do esmalte, antes da utilização do cimento autoadesivo RelyX U100, não teve relevância clínica na qualidade marginal de restaurações indiretas de resina composta no período avaliado. E ainda, que a presença de pequenos defeitos marginais não interferiu na longevidade clínica das restaurações que alcançaram um mínimo 93,75% de critério Alpha aos 12 meses. / Abstract: In vitro studies have suggested enamel-etching before luting indirect restorations with the self-adhesive cement RelyX Unicem. However, there is no scientific proof that this procedure has any clinical relevance. The aim of this in vivo study was to evaluate the effect of enamel etching on the marginal quality of indirect composite resin restorations (inlay/onlay) using the self-adhesive cement RelyX U100. Forty-two posterior teeth were selected from 25 patients that presented one or two teeth with large restorations in need of replacement. The teeth were prepared for indirect restorations (inlay/onlay). Next, the teeth were molded with polyvinylsiloxane and protected with interim restorations. The composite resin restorations were built over plaster casts using the incremental technique. Using a LED device, increments were light-cured for 40s for dentin opacity shades and 20s for all other shades. After one week, patients returned so that indirect restorations could be cemented. Teeth were isolated with rubber dams and the restorations were luted according to one of the following protocols: Etched group - selective enamel-etching + self-adhesive cement; Non-etched group - selfadhesive cement alone. The restorations were kept under finger-pressure for 2 minutes while removing excess cement. Each face was then light-cured for 60s. Recalls occurred after 1 week (baseline) and 12 months when the teeth were photographed, molded and evaluated according to previously established scores (USPHS criteria). Epoxy resin replicas were examined by SEM at X18 to X200. The results were expressed as percentage of the total observable marginal length for each parameter. No statistical difference was found between groups with an exception for the 'restoration margin fracture' quality (MEV analysis) for the nonetched group. Time degraded somewhat the restorations margins with underfilling being the more frequent find. We concluded that enamel-etching had no clinical relevance on marginal quality for indirect composite resin restorations luted with RelyX U100 self-adhesive cement during 12 months. Moreover, the presence of small marginal defects did not interfere in the clinical longevity of the restorations that reached at least 93,75% of the Alpha criteria after 12 months. / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários

Page generated in 0.0762 seconds