Spelling suggestions: "subject:"icroscopy alectron"" "subject:"icroscopy dlectron""
71 |
Intercambialidade de componentes protéticos em diferentes marcas de implantes / Evaluation of the connecting accuracy of interchanged prosthetic abutments to different dental implants using scanning electron microscopyZanardi, Piero Rocha 05 November 2012 (has links)
O presente estudo avaliou a intercambiabilidade dos componentes protéticos de implantes de hexágono externo medindo-se a precisão da interface implante/pilar (I/P) com microscopia eletrônica de varredura. Foram utilizados dez implantes para cada uma de três marcas (SIN, Conexão, Neodent) com seus respectivos pilares (base metálica de CoCr , rotacional e não rotacional) e um de marca alternativa (Microplant) em um arranjo com todas as combinações de I/P possíveis. O valor de referência para a intercambiabilidade das várias marcas de componentes foi definido pela diferença do pilar original para com seu respectivo implante. Dessa maneira, a intercambiabilidade foi considerada válida quando o resultado para um determinado pilar colocado sobre um implante fosse igual ou menor que a diferença medida, quando o pilar da mesma marca do implante foi posicionado. Um grau de desajuste foi observado em todos os espécimes. De uma maneira geral, o pilar antirrotacional foi mais preciso do que o rotacional. Estes variaram de 0,6 16,9m, com mediana 4,6m, enquanto o antirrotacional foi de 0,3 12,9m, com mediana de 3,4m. Os espécimes com o pilar e o implante Conexão tiveram uma diferença maior que o conjunto original para SIN e NEO (p<0,05). Apesar de estes últimos apresentarem resultados semelhantes com seus respectivos pilares, quando trocados, não mantiveram a mesma precisão original. Os resultados sugerem que a marca alternativa seria a única que apresentaria compatibilidade com todos os sistemas, enquanto as outras marcas não seriam completamente intercambiáveis. / The present study evaluated the interchangeability of prosthetic components for external hexagon implants by measuring the precision of the implant/abutment (I/A) interface using scanning electron microscopy. Ten implants for each of three brands (SIN, Conexão, Neodent) were tested with their respective abutments (milled CoCr collar rotational and non-rotational) and that of an alternative manufacturer (Microplant) in randomly arranged I/A combinations. The degree of interchangeability between the various brands of components was defined using the original abutment interface gap with its respective implant as the benchmark dimension. Accordingly, when the result for a given component placed on an implant was equal to or smaller then that gap measured when the component of the same brand as the implant was positioned, interchangeability was considered valid. Some degree of maladjustment was observed on all specimens. Generally, the non-rotational component was more accurate than its rotational counterpart. The latter samples ranged from 0.6 16.9m, with a median of 4.6m; the former from 0.3 12.9m, with a median of 3.4m. Specimens with the abutment and fixture from Conexão had larger microgap than the original set for Sin and Neodent (p<0.05). Even though the latter systems had similar results with their respective components, their interchanged abutments did not reproduce the original accuracy. The results suggest that the alternative brand abutment would have compatibility with all systems while the other brands were not completely interchangeable.
|
72 |
Identification and characterization of mitochondrial genome concatemers in AIDS-associated lymphomas and lymphoma cell linesBedoya, Felipe. January 2009 (has links)
Dissertation (Ph.D.)--University of South Florida, 2009. / Title from PDF of title page. Document formatted into pages; contains 115 pages. Includes vita. Includes bibliographical references.
|
73 |
Avaliação da customização por desgaste de pinos pré-fabricados de fibra de vidro / Evaluation of fibre posts submitted to customization of the apical portionAna Regina Cervantes Dias 25 January 2012 (has links)
O objetivo deste estudo foi avaliar pinos pré-fabricados de fibra de vidro (White Post DC/FGM) submetidos à customização por desgaste da porção apical. Experimento 1: 5 pinos n. 4 foram divididos em 5 grupos (G) de acordo com o instrumento de desgaste: GA - sem desgaste, GB- mini torno industrial (Dentsply), GC - ponta diamantada n. 3195F (KG Sorensen), GD - disco de lixa de granulação média (Sof-Lex/3M/ESPE), GE- alicate (Tramontina). Observou-se a micromorfologia dos pinos em microscópio eletrônico de varredura (ZEISS/DSM 960). Experimento 2: 60 pinos de diferentes diâmetros foram divididos em 6 grupos: G0 - pinos n. 0,5, G1 - pinos n. 1, G2 - pinos n. 2, G3 - pinos n. 3, G4 - pinos n.4, G5 - pinos n. 4 com terço apical desgastado com discos de lixa até o equivalente ao terço apical dos pinos n. 2. Os pinos foram submetidos ao teste de flexão de 3 pontos na máquina de ensaios universal (Instron 5500 R), conforme ISO 10477. Experimento 3: 20 caninos humanos permanentes sofreram tratamento endodôntico e remoção das coroas clínicas padronizando 15 mm de remanescente radicular. Os dentes foram incluídos em resina acrílica com simulação do ligamento periodontal, receberam férula de 2 mm e foram divididos em 2 grupos: GI - pinos n. 4 cimentados em condutos preparados com broca equivalente ao pino (FGM), GII - pinos n. 4 customizados no terço apical cimentados em condutos preparados com brocas (FGM) equivalentes aos pinos n. 2 em 10 mm e n. 4 em 5 mm. Os pinos foram cimentados com cimento resinoso (Rely X U100/3M/ESPE), os corpos de prova receberam coroas diretas de resina composta (Enforce Core/Dentsply) padronizadas com coras de policarbonato (TDV) e foram submetidos ao teste de resistência à fratura na Instron a 45da ferramenta cilíndrica, com força de 500 N aplicada a 2 mm da incisal na face palatina/lingual, com velocidade de 0,5 mm/min até falha. O padrão de fratura foi classificado em favorável ou desfavorável. Os resultados foram tratados estatisticamente por teste de análise de variância (ANOVA, p<0,05). Os resultados dos testes de flexão e fratura foram respectivamente: G0 - 58,406,40; G1 - 83,959,43; G2- 103,4219,17; G3 - 160,7817,30; G4 - 170,4711,28; G5 - 106,3521,96; GI - 303,0262,21 e GII - 402,81131,97. O padrão de fratura foi tratado por Mann-Whitney que observou semelhança estatística entre os grupos. Concluiu-se que o desgaste de pinos de fibra de vidro com pontas diamantadas ou discos de lixa produz alterações micromorfológicas aceitáveis. O corte com alicate deve ser evitado. A customização por desgaste da porção apical de pinos de fibra de vidro diminui a resistência à flexão a valores aceitáveis. Dentes restaurados com pinos de fibra de vidro customizados por desgaste possuem resistência à fratura superior a dentes restaurados com pinos intactos. A customização por desgaste facilita a adaptação do pino ao conduto radicular e preserva a estrutura dental. / The purpose of this study was to evaluate fibre posts (White Post DC/FGM) submitted to customization of the apical portion. Experiment 1: 5 #4 posts were divided into five groups (G) and submitted to different custom adaptation treatments: GA no surface treatment, GB- industrial shaping tool (Dentsply), GC- #3195 fine diamond bur (KG Sorensen), GD- medium-grain paper discs (Sof-Lex/3M/ESPE), GE pliers (Tramontina). The micromorphology of the posts was observed in a scanning electron microscope (ZEISS/DSM 960). Experiment 2: 60 posts of different diameters were divided into six groups: G0 #0.5 posts, G1 #1 posts, G2 #2 posts, G3 - #3 posts; G4 - #4 posts and G5 #4 posts submitted to custom adaptation of the apical portion with paper discs until the diameter was equivalent to #2 posts. The posts were submitted to a 3 point bending test in a universal testing machine (Instron/5500 R), according to ISO 10477. Experiment 3: 20 freshly extracted permanent healthy human canines with similar size were endodontically treated and the crowns were removed, leaving a remaining root length of 15 mm. The teeth were embedded in acrylic resin with simulation of the periodontal ligament, received a 2 mm ferule and were divided into two groups: G1- 10 #4 posts were cemented into post spaces prepared with #4 drill (FGM) at 10 mm, G2 - 10 #4 customized posts were cemented into root spaces prepared with #2 drill (FGM) at 10 mm and #4 drill (FGM) at 5 mm. The posts were cemented with resin cement (Rely X U100/3M/ESPE), and the teeth received direct crowns of composite resin (Enforce Core/Dentsply), standardized with polycarbonate crowns (TDV). The fracture strength was measured on an Instron, at 45 degrees to the long axis of the tooth, until fracture. The 500 N cylindrical load was applied to the buccal/lingual axis 2 mm below the incisal line, at crosshead speed of 0.5 mm/min. The fracture pattern was observed and classified as favorable or unfavorable. The results were submitted to ANOVA (p<0.05). Flexural strength and resistance to fracture data were, respectively: G0 58.40+6.40; G1 83.95+9.43; G2 103.42+19.17; G3 160.78+17.30; G4- 170.47+11.28; G5 106.35+21.96;GI 303.02+62.21 and GII 402.81+131.97. Fracture patterns were statistically similar according to Mann-Whitney test. It was concluded that customization of fibre posts with diamond burs or paper discs produces acceptable micromorphological changes. The cut of the post with pliers should be avoided. Grounding of the apical portion of fibre posts reduces the flexural strength to acceptable values. Teeth restored with grounded fiber posts have grater fracture strength than teeth restored with intact posts. Grounding of the post facilitates adaptation to root walls and preserves tooth structure.
|
74 |
Avaliação do aquecimento ósseo, da viabilidade celular imediata e da deformação de fresas de alta resistência após osteotomia para implantes em tíbias de coelhosCarvalho, Abrahão Cavalcante Gomes de Souza [UNESP] 15 December 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:41Z (GMT). No. of bitstreams: 0
Previous issue date: 2008-12-15Bitstream added on 2014-06-13T20:30:33Z : No. of bitstreams: 1
carvalho_acgs_me_araca.pdf: 682833 bytes, checksum: 3da34d67f34af6e497f53ac11e8e701c (MD5) / O propósito deste trabalho foi avaliar a influência da reutilização de fresas de alta resistência sobre o aquecimento ósseo, a viabilidade celular imediata e a deformação das fresas após osteotomia para implantes em tíbias de coelhos. Para isso, foram utilizados 12 coelhos machos brancos (Oryctolagus cunilicus, Nova Zelândia), que foram submetidos a 200 sequências de fresagens para implantes na cortical superior de suas tíbias. Foram estabelecidos 6 grupos (G1 a G6) que correspondiam ao número de osteotomias realizadas por cada fresa (0, 10, 20, 30, 40 e 50). Cada leito cirúrgico recebia a seguinte sequência de fresagem: fresa tipo lança e helicoidais de 2,0mm, 2,8mm, 3,0mm e 3.15mm. As áreas osteotomizadas foram coletadas para análise imunoistoquímica, as oscilações térmicas foram quantificadas e as fresas utilizadas receberam análise por microscopia eletrônica de varredura. Nos resultados, houve uma correlação alta entre a porcentagem de deformação e o número de reutilização de cada fresa (Coeficiente de Correlação de Pearson r = 0,984). Observou-se também que as fresas do tipo lança apresentaram maior deformação após o uso do que as fresas helicoidais (proporção de 2:1). Não houve correlação estatística significativa entre aumento da reutilização da fresa e aquecimento ósseo (p > 0,05). No entanto, observouse que a oscilação térmica durante a fresagem da lança é maior que as demais fresagens (proporção de 3:1). Na análise imunoistoquímica, observou-se um equilíbrio fisiológico da expressão das proteínas Osteoprotegerina e RANKL em todos os grupos, no entanto, houve maior expressão de todas as proteínas no Grupo 6. De acordo com a metodologia aplicada, foi possível concluir que as fresas avaliadas não causam aquecimento ósseo significativo em até 50 reutilizações, no entanto, causam maior trauma tecidual na 50ª fresagem... / The purpose of this study was evaluate the influence of high resistence drill reuse over bone heating, immediate bone-cell viability and drills wear after implant osteotomies in rabbit tibias. Therefore, 12 male white rabbits (Oryctolagus cunilicus, New Zealand) received 200 implant sequential osteotomies over the superior cortical of their tibia. Six groups were established (G1 to G6), according to the number of osteotomy of each drill (0, 10, 20, 30, 40 and 50). The implant sequence of drills was: spear drill, 2,0mm, 2.8mm, 3.0mm and 3.15mm helicoidal drills. The receptor-beds were collected to imunohistochemistry, the thermal changes were quantified and the drills received scanning electron microscopy analysis. In the results, a great correlation degree between drill wear and number of osteotomies was observed (Pearson’s Correlation Coefficient r = 0,984). Another result was that spear drill have more deformation than helicoidal drills (2:1 proportion). The bone heating analysis concluded that there was no statistical siginificance between number of osteotomy and bone heating (p > 0,05). However, the thermal changes during spear drilling was greater than during helicoidal drillings (3:1 proportion). Imunohistochemistry results showed a physiological balance of Osteoprotegerin and RANKL immunolabeling in all groups, however there was a greater immunolabeling of all proteins in the last group. According to this metodology, the conclusion is that the tested drills do not caused significant bone heating after 50 reuses, however, they caused more tissue trauma at 50th osteotomy. So, the studied system must be reused for 40 times, and the spier drill must be substituted after 20 osteotomies.
|
75 |
Avaliação "in vitro" da microinfiltração marginal e análise da fenda marginal cervical através da microscopia eletrônica de varredura, em restaurações de classe V de resina composta. Efeito dos sistemas adesivos e técnica de preparo cavitário /Orbegoso Flores, Victor Humberto. January 2001 (has links)
Orientador: Marcelo Ferrarezi de Andrade / Banca: Marcos Ribeiro Moysés / Banca: Alberto Magno Gonçalves / Banca: Sillas Luiz Lordelo Duarte Júnior / Banca: Sizenando de Toledo Porto Neto / Resumo: O objetivo deste trabalho foi avaliar a formação de fendas marginais cervicais através da microscopia eletrônica de varredura, assim como, a microinfiltração marginal em preparos de classe V. foram utilizadas duas técnicas de preparo: P1 utilizando fresa carbide no 245 e P2 que utilizou o jato de ar abrasivo Mach 4.0 (80psi de pressão, 27 æm de tamanho de partícula). O tamanho das cavidades foi padronizado com 1,5 mm de profundidade, 2,0 mm de altura e 3,0 mm de largura. Os materiais utilizados foram: G1 -Optibond solo Plus, G2 - Prime & BondNT e G3 - Scotchbond Multiuso Plus (grupo controle), a resina composta Point 4 utilizada para restaurar as cavidades foi padronizada para todas as restaurações. Foram utilizados 42 dentes molares hígidos divididos em 3 grupos de 14 cada, utilizando a face vestibular e lingual sendo que os preparos mostraram a margem oclusal em esmalte e a margem cervical em cemento/dentina. Após as restaurações serem confeccionadas foram armazenadas em água deionizada durante 24 horas, para posteriormente realizar os procedimentos de acabamento e polimento, a seguir os dentes foram isolados com araldite e esmalte para unha e submetidos a testes de ciclagem térmico (400 ciclos)e imediatamente imersos numa solução de nitrato de prata, durante 2 horas, removidos, lavados e colocados numa solução fotoreveladora durante 16 horas. Nessas condições os dentes foram limpos e seccionados no sentido mésio/distal obtendo duas metades as quais por sua vez foram seccionadas no sentido vestíbulo lingual dividindo as restaurações pela metade. Assim, uma metade da restauração foi avaliada através da lupa esteroscópica para observar a microinfiltração e a outra metade preparada e metalizada para ser avaliada através da microscopia eletrônica de varredura. A análise estatística aplicada aos resultados permite concluir que... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The aim of this study was to evaluate the formation of cervical gap with SEM, and the marginal microleakage in cavities class V. There were used two techniques for the preparations: P1 using a carbide # 245 and P2 using abrasive air Mach 4.0 (80 psi of preasure, 27nm measurement of the particle). The measurements of the cavities were standardized in 1.5mm of deepness, 2,0mm of highness and 3,0mm of lengthiness. The materials used were: G1 Optibond Solo Plus, G2 Prime & Bond NT and G3 Scotchbond Multiuso Plus (control group), it was used the composite Point 4 as the restorative material for all cavities. Forty-two healthy molars, divided in three groups of 14 each one, were used. Cavities were prepared in the buccal and lingual faces, its occlusal margin was in enamel and its cervical margin was in dentin/cement. After that finishing and polishing was made. Teeth were isolated with analdite and nail varnish and thermocycled (400 times). The preparations were dyed with "silver nitrate" for two hours. Preparations were stored in a photo developing solution for 16 hours. After that time teeth were cleaned and cut (buccal/lingual) Half of the preparation was observed in a stereoscopic microscope and the other half in a SEM. Results: 1.Preparations with abrasive air had a bigger gap; 2.Adhesive systems do not eliminate the formation of gaps; 3.Best results were found in the group prepared with bur and the adhesive Optibond Solo Plus, with a cervical gap 0,84nm, and in the other hand Scotchbond Multiuso Plus showed marginal gaps of 6,36nm; 4.In the occlusal margin Optibond Solo Plus had more microleakage tha Scotchbond Multiuso Plus and Prime & Bond NT.; 5. In the cervical margin, Optibond Solo Plus had good behavior controlling the marginal microleakage, compared with Scotchbond Multiuso Plus and Prime & Bond that had similar leakage between... (Complete abstract, click electronic address below). / Doutor
|
76 |
Avaliação da customização por desgaste de pinos pré-fabricados de fibra de vidro / Evaluation of fibre posts submitted to customization of the apical portionAna Regina Cervantes Dias 25 January 2012 (has links)
O objetivo deste estudo foi avaliar pinos pré-fabricados de fibra de vidro (White Post DC/FGM) submetidos à customização por desgaste da porção apical. Experimento 1: 5 pinos n. 4 foram divididos em 5 grupos (G) de acordo com o instrumento de desgaste: GA - sem desgaste, GB- mini torno industrial (Dentsply), GC - ponta diamantada n. 3195F (KG Sorensen), GD - disco de lixa de granulação média (Sof-Lex/3M/ESPE), GE- alicate (Tramontina). Observou-se a micromorfologia dos pinos em microscópio eletrônico de varredura (ZEISS/DSM 960). Experimento 2: 60 pinos de diferentes diâmetros foram divididos em 6 grupos: G0 - pinos n. 0,5, G1 - pinos n. 1, G2 - pinos n. 2, G3 - pinos n. 3, G4 - pinos n.4, G5 - pinos n. 4 com terço apical desgastado com discos de lixa até o equivalente ao terço apical dos pinos n. 2. Os pinos foram submetidos ao teste de flexão de 3 pontos na máquina de ensaios universal (Instron 5500 R), conforme ISO 10477. Experimento 3: 20 caninos humanos permanentes sofreram tratamento endodôntico e remoção das coroas clínicas padronizando 15 mm de remanescente radicular. Os dentes foram incluídos em resina acrílica com simulação do ligamento periodontal, receberam férula de 2 mm e foram divididos em 2 grupos: GI - pinos n. 4 cimentados em condutos preparados com broca equivalente ao pino (FGM), GII - pinos n. 4 customizados no terço apical cimentados em condutos preparados com brocas (FGM) equivalentes aos pinos n. 2 em 10 mm e n. 4 em 5 mm. Os pinos foram cimentados com cimento resinoso (Rely X U100/3M/ESPE), os corpos de prova receberam coroas diretas de resina composta (Enforce Core/Dentsply) padronizadas com coras de policarbonato (TDV) e foram submetidos ao teste de resistência à fratura na Instron a 45da ferramenta cilíndrica, com força de 500 N aplicada a 2 mm da incisal na face palatina/lingual, com velocidade de 0,5 mm/min até falha. O padrão de fratura foi classificado em favorável ou desfavorável. Os resultados foram tratados estatisticamente por teste de análise de variância (ANOVA, p<0,05). Os resultados dos testes de flexão e fratura foram respectivamente: G0 - 58,406,40; G1 - 83,959,43; G2- 103,4219,17; G3 - 160,7817,30; G4 - 170,4711,28; G5 - 106,3521,96; GI - 303,0262,21 e GII - 402,81131,97. O padrão de fratura foi tratado por Mann-Whitney que observou semelhança estatística entre os grupos. Concluiu-se que o desgaste de pinos de fibra de vidro com pontas diamantadas ou discos de lixa produz alterações micromorfológicas aceitáveis. O corte com alicate deve ser evitado. A customização por desgaste da porção apical de pinos de fibra de vidro diminui a resistência à flexão a valores aceitáveis. Dentes restaurados com pinos de fibra de vidro customizados por desgaste possuem resistência à fratura superior a dentes restaurados com pinos intactos. A customização por desgaste facilita a adaptação do pino ao conduto radicular e preserva a estrutura dental. / The purpose of this study was to evaluate fibre posts (White Post DC/FGM) submitted to customization of the apical portion. Experiment 1: 5 #4 posts were divided into five groups (G) and submitted to different custom adaptation treatments: GA no surface treatment, GB- industrial shaping tool (Dentsply), GC- #3195 fine diamond bur (KG Sorensen), GD- medium-grain paper discs (Sof-Lex/3M/ESPE), GE pliers (Tramontina). The micromorphology of the posts was observed in a scanning electron microscope (ZEISS/DSM 960). Experiment 2: 60 posts of different diameters were divided into six groups: G0 #0.5 posts, G1 #1 posts, G2 #2 posts, G3 - #3 posts; G4 - #4 posts and G5 #4 posts submitted to custom adaptation of the apical portion with paper discs until the diameter was equivalent to #2 posts. The posts were submitted to a 3 point bending test in a universal testing machine (Instron/5500 R), according to ISO 10477. Experiment 3: 20 freshly extracted permanent healthy human canines with similar size were endodontically treated and the crowns were removed, leaving a remaining root length of 15 mm. The teeth were embedded in acrylic resin with simulation of the periodontal ligament, received a 2 mm ferule and were divided into two groups: G1- 10 #4 posts were cemented into post spaces prepared with #4 drill (FGM) at 10 mm, G2 - 10 #4 customized posts were cemented into root spaces prepared with #2 drill (FGM) at 10 mm and #4 drill (FGM) at 5 mm. The posts were cemented with resin cement (Rely X U100/3M/ESPE), and the teeth received direct crowns of composite resin (Enforce Core/Dentsply), standardized with polycarbonate crowns (TDV). The fracture strength was measured on an Instron, at 45 degrees to the long axis of the tooth, until fracture. The 500 N cylindrical load was applied to the buccal/lingual axis 2 mm below the incisal line, at crosshead speed of 0.5 mm/min. The fracture pattern was observed and classified as favorable or unfavorable. The results were submitted to ANOVA (p<0.05). Flexural strength and resistance to fracture data were, respectively: G0 58.40+6.40; G1 83.95+9.43; G2 103.42+19.17; G3 160.78+17.30; G4- 170.47+11.28; G5 106.35+21.96;GI 303.02+62.21 and GII 402.81+131.97. Fracture patterns were statistically similar according to Mann-Whitney test. It was concluded that customization of fibre posts with diamond burs or paper discs produces acceptable micromorphological changes. The cut of the post with pliers should be avoided. Grounding of the apical portion of fibre posts reduces the flexural strength to acceptable values. Teeth restored with grounded fiber posts have grater fracture strength than teeth restored with intact posts. Grounding of the post facilitates adaptation to root walls and preserves tooth structure.
|
77 |
Estudo da interface entre uma resina autoadesiva e a dentina hígida ou afetada por cárie / Study of a interface created by a self-adhesive resin and sound or caries-affected dentinPaula Mendes Acatauassú Carneiro 10 November 2017 (has links)
O objetivo desde estudo foi analisar a microdureza e as características morfológicas da interface de união entre uma resina composta flow autoadesiva (Vertise Flow) e a dentina humana hígida ou afetada por cárie, em comparação às interfaces formadas por outros dois materiais: um cimento de ionômero de vidro modificado por resina (Fuji II LC) e um sistema adesivo universal (Single Bond Universal). Foram realizadas cavidades do tipo classe I na dentina oclusal de molares humanos e dentina afetada por cárie foi produzida na parede pulpar das cavidades por meio do método microbiológico. Os espécimes foram restaurados de acordo com os grupos experimentais e cortados no sentido vestíbulo-lingual para evidenciação da interface adesiva. Os espécimes foram submetidos aos ensaios de microdureza Knoop (n=5) e analisados por meio de microscopia eletrônica de varredura (n=3) e microscopia confocal de varredura a laser (n=10). A análise de variância dois fatores e teste de Tukey foram realizados para a análise estatística quantitativa da variável dureza (p<0,05%). As características morfológicas foram descritas após análise qualitativa. A dureza da camada de material variou em função da composição de cada material. A dureza da camada híbrida foi influenciada de acordo com o material e os maiores valores de dureza foram obtidos quando o sistema adesivo universal foi utilizado. A camada híbrida formada pela dentina afetada por cárie apresentou dureza inferior independente do material utilizado. Quanto à morfologia, os materiais testados promoveram a formação de interfaces com características diferentes entre si, entretanto, todos os materiais foram capazes de formar tags na camada híbrida. Porém, quando a interface envolveu a dentina afetada por cárie, observou-se maior quantidade de falhas e as camadas apresentaram-se irregulares. / The aim of this study was to analyze the microhardness and morphological characteristics of the bonding interface between a self-adhesive flowable composite (Vertise Flow) and sound or caries-affected dentin, comparing to interfaces formed by other materials: a resin-modified glass ionomer cement (Fuji II LC) and a universal adhesive system (Scotchbond Universal Adhesive). Class I cavities were made in the occlusal dentin of human molars and dentin affected by caries was produced in their pulp wall, using the microbiological method. The specimens were restored according to the experimental groups and cut in the vestibular-lingual direction to expose the adhesive interface. The specimens were submitted to transversal Knoop microhardness tests (n=5) and analyzed by scanning electron microscopy (n=3) and confocal laser scanning microscopy (n=10). Two-way repeated measures analysis of variance and Tukey\'s post-hoc tests were performed for the hardness results (?:0.05). Morphological characteristics were qualitative analyzed. The hardness of the material layer varied according to the composition of each material. The hardness of the hybrid layer was influenced according to the material and the highest values of hardness were obtained when the universal system was used (p<0.05). The hybrid layer formed by dentin caries-affected presented low hardness values independently of the material used. Morphologically, the tested materials promoted the formation of interfaces with different characteristics, although all the materials were able to form tags in dentin. However, when the interfaces involved caries-affected dentin, a greater number of defects were observed and the layers were irregular.
|
78 |
O uso do laser de CO2 na prevenção da carie dentaria / The use of CO2 laser in dental caries preventionRodrigues, Lidiany Karla Azevedo 14 July 2005 (has links)
Orientador: Marines Nobre dos Santos Uchoa / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T20:08:54Z (GMT). No. of bitstreams: 1
Rodrigues_LidianyKarlaAzevedo_D.pdf: 4376856 bytes, checksum: 25da7c3f75a95b91dee027db3b7a19fa (MD5)
Previous issue date: 2005 / Resumo: A irradiação do esmalte dental com laser de CO2, especialmente se associada ao flúor, aumenta a resistência deste substrato ao desafio ácido. Deste modo, esta tese, constituída por 3 artigos, teve por objetivos: (1) descrever as características do laser de CO2 e revisar a literatura disponível enfocando seus efeitos na prevenção de cárie em esmalte e dentina, bem como discutir os efeitos deste mesmo laser quando associado ao flúor; (2) investigar, in vitro, o efeito do laser de CO2 (? = 10,6 µm), com duas densidades de energia, na inibição da desmineralização ao redor de restaurações de resina composta; (3) avaliar in situ os efeitos combinados de um TEA (Transversely Excited Atmospheric-pressure) laser de CO2 (? = 9,6 µm) e do dentifrício fluoretado na desmineralização do esmalte dental humano. No estudo 1, a literatura científica pertinente ao assunto foi pesquisada usando a base de dados medline e busca manual de referências citadas em artigos científicos. No estudo 2, preparos cavitários realizados com ponta diamantada em esmalte hígido tiveram seu ângulo cavo-superficial irradiado com laser de CO2 com 8 ou 16 J/cm2. Através de microdureza em corte longitudinal, avaliou-se a perda mineral in vitro dos grupos experimentais e controle no esmalte ao redor da restauração. No estudo 3, foi testado in situ o efeito do laser de CO2 com 1,5 J/cm2 associado ou não à utilização de dentifrício fluoretado na prevenção de cárie dentária. Avaliou-se a perda mineral do esmalte dental humano nos grupos experimentais e controle. Os resultados dos estudos 2 e 3 foram analisados estatisticamente pelos testes ANOVA e Tukey com nível de significância fixado em 5%. A análise da literatura apresentada no artigo 1 mostrou que pode haver um futuro promissor para o laser de CO2 na prevenção de cárie dentária tendo seu efeito preventivo potencializado quando utilizado em associação a compostos fluoretados. Os resultados do artigo 2 demonstraram que o laser utilizado foi efetivo na inibição da desmineralização do esmalte ao redor de restaurações de resina composta (p < 0,05) e que o aumento da energia não potencializou o efeito do laser. No terceiro estudo, observou-se que os tratamentos com laser e/ou dentifrício fluoretado foram capazes de inibir a desmineralização do esmalte in situ, tendo sido observado o melhor resultado de inibição da desmineralização quando o laser foi associado à utilização de dentifrício fluoretado. Em conclusão, os resultados desses estudos indicam que o laser de CO2 é capaz de inibir a desmineralização do esmalte dental humano em situações de alto desafio cariogênico in vitro e in situ, apresentando efeito sinérgico quando associado ao flúor / Abstract: The irradiation of dental enamel by CO2 laser, especially if combined with fluoride, increases the enamel acid resistance. Thus, this thesis, comprised by 3 manuscripts, aimed: (1) to describe the characteristics of the CO2 laser and to review the literature with regard to its effects on caries inhibition in enamel and dentin. Another aim of this review is to discuss the effects of the CO2 laser in combination with fluoride; (2) to investigate, in vitro, the effect of a carbon dioxide laser (? = 10.6 µm), with two energy densities, on the enamel inhibition of demineralization around composite restorations; (3) to assess in situ the combined effects of a 9.6 µm TEA (Transversely Excited Atmospheric-pressure) CO2 laser and fluoride dentifrice on the demineralization of human dental enamel. In study 1, the scientific literature related to the issue was searched using medline and manual tracing of
references cited scientific papers. In study 2, cavity preparations performed with diamond bur on sound enamel had their cavo surface angle irradiated with CO2 laser using 8 or 16 J/cm2. In vitro mineral loss, in experimental and control groups, was evaluated in the enamel around the restoration. In manuscript 3, the in situ caries preventive effect of the CO2 laser, with 1.5 J/cm2, associated or not to fluoridated dentifrice, was tested. In the human dental enamel, mineral loss was evaluated, by cross-sectional microhardness, in experimental and control groups. The results of studies 2 and 3 were analyzed by ANOVA and Tukey test. The literature analysis presented in study 1 showed that there can be a promising future for CO2 laser in caries prevention and its preventive effect is improved when associated to fluoride products. The results of study 2 demonstrated that the laser used was effective in inhibiting enamel demineralization around the composite restorations (p < 0.05). In the third manuscript, it was observed that the treatments with laser and/or fluoridated dentifrice were able to inhibit the in situ enamel demineralization and the best demineralization inhibition result was observed when laser was combined with fluoridated dentifrice use. In conclusion, the results of these studies suggest that CO2 laser is able of inhibiting enamel demineralization, in in vitro and in situ high cariogenic challenge situations, showing synergic effect with fluoride / Doutorado / Cariologia / Doutor em Odontologia
|
79 |
Intercambialidade de componentes protéticos em diferentes marcas de implantes / Evaluation of the connecting accuracy of interchanged prosthetic abutments to different dental implants using scanning electron microscopyPiero Rocha Zanardi 05 November 2012 (has links)
O presente estudo avaliou a intercambiabilidade dos componentes protéticos de implantes de hexágono externo medindo-se a precisão da interface implante/pilar (I/P) com microscopia eletrônica de varredura. Foram utilizados dez implantes para cada uma de três marcas (SIN, Conexão, Neodent) com seus respectivos pilares (base metálica de CoCr , rotacional e não rotacional) e um de marca alternativa (Microplant) em um arranjo com todas as combinações de I/P possíveis. O valor de referência para a intercambiabilidade das várias marcas de componentes foi definido pela diferença do pilar original para com seu respectivo implante. Dessa maneira, a intercambiabilidade foi considerada válida quando o resultado para um determinado pilar colocado sobre um implante fosse igual ou menor que a diferença medida, quando o pilar da mesma marca do implante foi posicionado. Um grau de desajuste foi observado em todos os espécimes. De uma maneira geral, o pilar antirrotacional foi mais preciso do que o rotacional. Estes variaram de 0,6 16,9m, com mediana 4,6m, enquanto o antirrotacional foi de 0,3 12,9m, com mediana de 3,4m. Os espécimes com o pilar e o implante Conexão tiveram uma diferença maior que o conjunto original para SIN e NEO (p<0,05). Apesar de estes últimos apresentarem resultados semelhantes com seus respectivos pilares, quando trocados, não mantiveram a mesma precisão original. Os resultados sugerem que a marca alternativa seria a única que apresentaria compatibilidade com todos os sistemas, enquanto as outras marcas não seriam completamente intercambiáveis. / The present study evaluated the interchangeability of prosthetic components for external hexagon implants by measuring the precision of the implant/abutment (I/A) interface using scanning electron microscopy. Ten implants for each of three brands (SIN, Conexão, Neodent) were tested with their respective abutments (milled CoCr collar rotational and non-rotational) and that of an alternative manufacturer (Microplant) in randomly arranged I/A combinations. The degree of interchangeability between the various brands of components was defined using the original abutment interface gap with its respective implant as the benchmark dimension. Accordingly, when the result for a given component placed on an implant was equal to or smaller then that gap measured when the component of the same brand as the implant was positioned, interchangeability was considered valid. Some degree of maladjustment was observed on all specimens. Generally, the non-rotational component was more accurate than its rotational counterpart. The latter samples ranged from 0.6 16.9m, with a median of 4.6m; the former from 0.3 12.9m, with a median of 3.4m. Specimens with the abutment and fixture from Conexão had larger microgap than the original set for Sin and Neodent (p<0.05). Even though the latter systems had similar results with their respective components, their interchanged abutments did not reproduce the original accuracy. The results suggest that the alternative brand abutment would have compatibility with all systems while the other brands were not completely interchangeable.
|
80 |
Influência de materiais obturadores e agentes de limpeza na resistência da união e interface adesiva de pinos de fibra de vidro à dentina intrarradicular / Influence of filling materials and cleaning agents on bond strength and adhesion interface of glass fiber post to radicular dentinIwamoto, Alexsandra Shizue, 1987- 20 August 2018 (has links)
Orientadores: Fernanda Miori Pascon, Regina Maria Puppin Rontani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-20T05:29:10Z (GMT). No. of bitstreams: 1
Iwamoto_AlexsandraShizue_M.pdf: 5068520 bytes, checksum: 5edcd14cf180873ed3b9ce319f696504 (MD5)
Previous issue date: 2012 / Resumo: O objetivo do estudo foi avaliar in vitro a influência de diferentes materiais obturadores e agentes de limpeza na resistência da união de pinos de fibra de vidro à dentina radicular e na qualidade da interface adesiva. 156 raízes de dentes bovinos decíduos foram selecionadas, preparadas endodonticamente e distribuídas em 4 grupos de acordo com os materiais obturadores (39 dentes): 1- Controle (sem material); 2- Pasta Calen® + óxido de zinco (OZ); 3- Pasta Vitapex®; 4- Pasta Calcipex II®. Após 7 dias, as raízes foram desobturadas e subdivididas de acordo com os agentes de limpeza (13 dentes): A - Controle (sem limpeza); B - Etanol a 70%; C - Tergenform®. A cimentação do pino foi realizada com cimento resinoso RelyXMR ARC após condicionamento com ácido fosfórico a 35 % e aplicação do sistema adesivo Adper Single BondTM 2. Os espécimes foram armazenados por 7 dias, seccionados e preparados para avaliação da resistência da união (n=10) e análise da interface por meio da infiltração por nitrato de prata (n=3). O teste push-out foi conduzido na máquina de ensaio universal EMIC com velocidade 0,5mm/min. Os dados obtidos em Kgf foram convertidos em MPa e submetidos à ANOVA dois fatores (materiais obturadores x agentes de limpeza) e ao teste Tukey (p<0,05). Amostras representativas dos grupos foram observadas em Microscopia Eletrônica de Varredura (MEV) após a realização do teste push-out para ilustrar a fratura ocorrida. Para avaliação qualitativa da interface adesiva entre dentina/cimento e cimento/pino, as áreas infiltradas pela solução de nitrato de prata foram observadas em MEV e mensuradas por um único examinador previamente calibrado (nível de coincidência intra-examinador=98%), calculadas em porcentagem e submetidas ao teste Kruskal-Wallis (p<0,05) e à análise descritiva. Para os resultados da resistência da união, verificou-se que houve interação entre os fatores de estudo (p=0.0043). A pasta Calen®+OZ e limpeza com etanol apresentou o maior valor de resistência da união, diferindo estatisticamente do grupo sem limpeza. Valores intermediários foram encontrados para a limpeza com Tergenform®. As pastas Vitapex® e Calcipex® não apresentaram diferenças entre os agentes de limpeza e menores valores de resistência da união foram para o grupo controle (sem material obturador) e limpeza com Tergenform®, diferindo dos outros agentes de limpeza. Observou-se que não houve diferença entre os grupos para a infiltração de prata nas interfaces adesivas entre cimento e dentina radicular, que variou de 20,63% a 56,62%. Dessa forma, pode-se concluir que: (1) os materiais obturadores e os agentes de limpeza interferiram na resistência da união de pinos de fibra de vidro e dentina radicular; (2) ao realizar a obturação do canal radicular com pasta Calen®+OZ o melhor agente de limpeza foi o etanol a 70%; (3) para as pastas Vitapex® e Calcipex II® não há necessidade de agentes de limpeza; e (4) todos os grupos sofreram infiltração na interface de união entre cimento/dentina radicular, independente dos materiais obturadores e agentes de limpeza estudados / Abstract: The aim of this in vitro study was to evaluate the post-cement-dentin adhesive interface quality and the effect of different filling materials and cleaning agents on the bond strength of glass fiber posts to primary root dentin. This study included 156 roots of bovine primary teeth which were endodontically treated and assigned to four groups (39 teeth each group) according to filling materials: 1 - control (no material); 2 - Calen® paste + zinc oxide (ZO); 3 - Vitapex® paste; and 4 - Calcipex II® paste. After seven days, the filling materials were removed and the roots for each material subdivided into 3 groups (13 teeth) according to cleaning agents: A - No cleaning (control); B - 70% ethanol; and C - Tergenform®. Glass fiber posts were luted using dual polymerized resin cement (RelyXMR ARC) after 35% acid etching, rinsing and application of the adhesive system (Adper Single BondTM 2). The specimens were stored for 7 days, sectioned and prepared for push-out bond strength test (n=10) and interface analysis by silver nitrate leakage (n=3). A push-out test was performed using a universal test machine (EMIC) at a crosshead speed of 0.5 mm/min. Data obtained in Kgf were converted into MPa and submitted to two-way ANOVA (filling materials x cleaning agents) and Tukey tests (p<0.05). After the push-out test, representative samples of the groups were submitted to scanning electron microscopy (SEM) to illustrate the failure modes. The adhesive interface between dentin/cement and cement/post were also analyzed by SEM. The leakage (expressed in percentage) was measured by a single examiner previously calibrated (intra-examiner coincidence level = 98%) using a silver nitrate solution. Data obtained for leakage were submitted to the Kruskal-Wallis test (p<0.05) and descriptive analysis. Interaction was observed between filling materials and cleaning agents, concerning bond strength values (p=0.0043). Calen® paste+ZO with 70% ethanol showed the highest values, significantly different from the groups using no cleaning agents. Vitapex® and Calcipex® showed no significant difference between cleaning agents. The lowest bond strength values were found for the control with Tergenform®. No statistical difference was observed between groups concerning silver leakage (20.63% to 56.62%) in the adhesive interface between cement and dentin. In conclusion, filling materials and cleaning agents influenced the bond strength, but not the adhesive interface between intracanal posts and root dentin; as a cleaning agent, 70% ethanol responded better to Calen® paste+ZO; cleaning agents are not required for Vitapex® and Calcipex®; all groups showed leakage in the adhesion interface between cement resin/dentin root, regardless of the filling materials and cleaning agents studied / Mestrado / Odontopediatria / Mestre em Odontologia
|
Page generated in 0.0631 seconds