• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 141
  • 36
  • 31
  • 5
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 225
  • 141
  • 131
  • 123
  • 53
  • 45
  • 42
  • 33
  • 31
  • 31
  • 26
  • 25
  • 24
  • 23
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação da estabilidade inicial de implantes instalados em modelos ósseos suínos padronizados em posicionamentos ao nível ou infraósseos / Evaluation of implants placed in bone standardized pig models in positions bone level or intraosseous using biomechanical tests and Micro-CT. An in vitro pilot study

Carvalho, Jessica Pires de 25 August 2016 (has links)
A estabilidade primária é decorrente da adaptação mecânica imediata entre o osso e o implante após a sua inserção. O sucesso desta adaptação depende de fatores como a densidade e qualidade ósseas, tamanho, diâmetro, forma e rugosidade da superfície do implante. As cargas oclusais aplicadas sobre o implante podem afetar o osso circundante. Esse estudo teve como objetivo avaliar, comparativamente, a estabilidade inicial de implantes ósseo inseridos em cilindros de osso suíno padronizados, em diferentes posicionamentos ósseos, com e sem a aplicação de carga, por meio de análises de imagens tridimensionais (microtomografia computadorizada) e análises mecânicas (Frequência de ressonância, Torque de inserção e Ensaio de arrancamento). Os cilindros ósseos foram preparados a partir de osso suíno e separados em 2 grupos conforme a área doadora: Grupo A: cilindros removidos da cabeça do fêmur (alta densidade óssea) e Grupo B: cilindros removidos do côndilo mandibular (baixa densidade óssea). Previamente aos procedimentos experimentais, os cilindros ósseos foram certificados através de análises de imagens 2D (radiografia digital), para garantir a uniformidade intra-grupos e distinção entre os grupos dos espécimes. Após a certificação, foram feitas microtomografias computadorizadas dos cilindros ósseos para análise tridimensional de imagens prévia à instalação dos implantes, avaliando os seguintes parâmetros: porcentagem de volume ósseo (BV/TV), separação trabecular (TbSp), razão entre a medida da área superficial do osso e o seu volume ósseo (BS/BV) e porcentagem de porosidade total (POTOT). Depois disso, foram selecionados 60 implantes, que foram divididos em 4 grupos, cada um com 15 implantes: G1 (cilindros ósseos de alta densidade com implante situados ao nível ósseo), G2 (cilindros ósseos de alta densidade com implante 2 mm infraósseo), G3 (cilindros ósseos de baixa densidade com implante ao nível ósseo) e G4 (cilindros de baixa densidade com implante 2 mm infraósseo). A instalação dos implantes seguiu o protocolo recomendado pelo fabricante e durante o procedimento foi realizada a medida do torque de inserção. Após a instalação dos implantes, os cilindros ósseos foram submetidos à nova análise tridimensional (com avaliação dos mesmos parâmetros anteriores, nas áreas intra-roscas e adjacente à estas, acrescidos da medida da área de contato ossoimplante (BIC). Foi então realizada a avaliação do Coeficiente de Estabilidade (ISQ), utilizando a análise de frequência de ressonância (Osstell®). Após essa avaliação, 5 implantes de cada grupo foram submetidos ao ensaio de arrancamento. Os 10 implantes de cada grupo restantes foram conectados a pilares protéticos adequados, os quais receberam uma aplicação de forças axial (G1, G2, G3 e G4, 5 implantes de cada grupo) e lateral (G1, G2, G3 e G4, 5 implantes de cada grupo). Após aplicação das forças, os cilindros ósseos foram submetidos a nova análise tridimensional com avaliação dos mesmos parâmetros descritos, a nova análise de frequência de ressonância e ao ensaio de arrancamento. As variáveis foram testadas em relação à normalidade dos dados. Para todas as análises foi considerado um nível de significância de 5%. As análises estatísticas foram realizadas com base nos dados absolutos obtidos durante a análise tridimensional em cada situação de carga (antes do implante, pósimplante e pós-carga) e com a variação entre os valores das situações pós-implante e póscarga (variação carga - implante). A avaliação estatística do parâmetro de análise de frequência de ressonância não encontrou diferenças estatisticamente significantes para as comparações entre grupos G1 versus G3 e G2 versus G4 nas avaliações pós implante e pós carga. Em relação ao torque de inserção, houve diferenças estatisticamente significantes para as comparações entre grupos com implantes instalados no mesmo nível G1 versus G3 e G2 versus G4. Os maiores valores de torque de inserção obtidos foram registrados nos grupos de alta densidade. A análise estatística do ensaio de arrancamento mostrou diferenças estatisticamente significantes para as comparações: G1 versus G3 (inicial) e G1 versus G4 (inicial). Após a aplicação de carga oclusal, pode-se constatar diferenças estatisticamente significantes para as comparações: G1 versus G3 e G2 versus G4, após aplicação de carga lateral a análise mostrou diferença estatisticamente significante para a comparação G3 versus G4. Os resultados das análises tridimensionais mostraram diferenças estatisticamente significantes para os parâmetros TbSp e POTOT na avaliação da área óssea intra-rosca. A avaliação dos dados de variação após a aplicação de carga oclusal e lateral para o parâmetro TbSp, mostrou diferenças estatisticamente significantes para as comparações G2 versus G4. Em relação ao parâmetro POTOT, a aplicação de carga oclusal e lateral mostrou diferença estatisticamente significante para as análises: G1 versus G2 e G2 versus G4. Em relação ao parâmetro BSBV a análise dos valores absolutos, mostrou diferenças estatisticamente significantes para a área óssea intra-rosca dos grupos de baixa densidade. Já a análise dos valores de variação, a aplicação de carga oclusal mostrou diferenças estatisticamente significantes para os grupos G1 versus G3, G2 versus G4 e G3 versus G4, enquanto a aplicação de carga não axial resultou em diferenças estatisticamente significantes para os grupos G3 versus G4 e G2 versus G4. Já a análise estatística dos dados de variação do parâmetro BV/TV, mostrou diferença estatisticamente significante para todas as comparações na área óssea intra-rosca após aplicação de carga oclusal e lateral. A análise estatística do parâmetro BIC mostrou diferenças significantes para os grupos de baixa densidade (G3 e G4) nas comparações pós implante e pós carga. Em relação aos dados de variação, pode-se constatar diferença estatisticamente significante na aplicação de carga axial para G1 versus G2 e G2 versus G4, enquanto a aplicação de carga lateral mostrou diferença estatisticamente significante para as comparações G1 versus G3 e G2 versus G4. De acordo com os dados obtidos pode-se concluir que a densidade óssea tem relação com a estabilidade primária de implantes, que cargas não axias são prejudiciais para o tecido ósseo peri-implantar e que o posicionamento infraósseo pode promover melhor resposta do tecido ósseo, principalmente em regiões de baixa densidade óssea. / With the increase of oral rehabilitation with implants, immediate load can be used to reduce the treatment time. It is important to perform correct treatment planning for immediate implant loading, using 3D image analysis. The subcrestal implant positioning is one of the possible factors that may impact the success of immediate loading implants. Objective: The aim of this study is to evaluate the initial stability of osseointegrated implants placed infra bone or at the bone level in standardized porcine bone cylinders, through image (microcomputerized tomography) and mechanical analysis (resonance frequency, insertion torque and pull out test). Sixty bone cylinders were prepared from fresh porcine bone and separated in 2 groups: Group A 30 cylinders removed from femur head (high bone density) and Group B - 30 cylinders removed from the mandibular condyle (low bone density). Before the experimental procedure, the bone cylinders were certificated through 2D images analysis (digital radiography) to calculated bone density. After this, the bone cylinders were evaluated through micro computed three-dimensional analysis before the implant insertion. The parameters were analyzed in 2 levels (L1-bone volume internal to the threads and L2 - immediately adjacent to the end of threads). The microtomographical parameters analyzed were: Bone volume/Total volume (BV/TV), Trabecular thickness (TbSp), Bone surface/Volume ratio (BS/BV) and Total porosity percent (POTOT). Then, 60 implants (Alvim, 3.5 mm x 10 mm, Neodent®, Curitiba) were inserted in bone cylinders (1 implant in each cylinder), according to manufacturers protocol, and insertion torque was recorded for each implant. After that, the bone cylinders were submitted a new micro computed tomography analysis that evaluated the same levels and parameters, and Bone Implant Contact (BIC) was also recorded. After that, 5 implants were submitted to pull out test while the others implants received axial and non- axial load. After that, a new microcomputerized tomography analysis evaluated the same levels and parameters previously described, and resonance frequency analysis and pullout test were performed in the bone cylinders. 3D analysis showed that pre- and post-implants intra-groups had statistically significant differences for TbSp and POTOT parameters, and for BSBV and BIC parameters there were observed statistically significant differences for low bone densities groups. The values of differences between post and before loading showed statistically significant differences between G2 and G4 for TbSp, POTOT, BSBV, BV/TV and BIC parameters. The RFA analysis showed highest values for G2 and G4. Concerning insertion torque, the highest mean values were found in high bone densities groups. The pullout strength test showed that the non- axial loads in the low bone density maybe lead to implant displacement throughout the implant insertion axis. Bone density has a direct relationship with implant primary stability. Non- axial loads are harmful to peri- implantar bone tissue and subcrestal placement of implants presented the best mechanical and tomographical results.
22

Análise ex vivo de cortes apicais de dentes humanos em 3D empregando microtomografia computadorizada / Ex vivo analysis of apical human tooth in 3D sections using computed micro-CT

Bardauil, Marcia Regina Ramalho da Silva 08 July 2010 (has links)
O objetivo deste estudo in vivo foi investigar as imagens obtidas por microtomografia computadorizada (micro-TC) no estudo da anatomia apical de dentes humanos portadores de polpa viva e mortificada. Trinta e cinco dentes humanos unirradiculares ou multirradiculares que tiveram suas raízes separadas totalizando quarenta e uma raízes foram rigorosamente pré-selecionadas e divididas em dois grupos: com polpa viva (PV) n = 21 e com polpa mortificada (PM) n = 20. Os dentes de ambos os grupos foram escaneados pelo sistema de microtomografia computadorizada (SkyScan 1172) com resolução de 6,7m e suas imagens reconstruídas para a análise da região apical nos cortes sagital e coronal. O diâmetro do forame apical (FA) e da junção cemento-dentina (JCD) foram medidos bem como suas distâncias (extensão do cemento) em ambos os lados da raiz. Posteriormente a coroa dos dentes foi cortada no seu colo anatômico e suas raízes foram medidas com paquímetro eletrônico e a odontometria realizada com localizador eletrônico apical (RomiApex A15). A subtração desses dois dados foi correlacionada com as medidas obtidas pela micro-TC na avaliação da posição da JCD. As raízes foram preparadas para avaliação histológica em cortes longitudinais de 6m de espessura e corados com HE. Os cortes que apresentaram a emergência do FA foram fotografados digitalmente e as imagens correspondentes de micro-TC foram sobrepostas com o intuito de ilustrar a metodologia utilizada. As medidas da micro-TC foram realizadas por dois examinadores devidamente instruídos. A concordância inter-examinadores foi confirmada pelo coeficiente de correlação intraclasse (ICC) e as medidas foram comparadas pelo teste de Mann-Whitney (teste de Wilcoxon rank sum - p0,05). Os resultados indicaram que não houve diferença estatisticamente significante quanto à extensão do cemento intrarradicular nos grupos quer de polpa viva como mortificada com distâncias de 0,32±0,1mm e 0,36±0,16mm respectivamente. As medidas realizadas pelo localizador apical, a 1,0mm aquém, garantiu o estabelecimento do limite dentro do canal dentinário. Os resultados encontrados para o diâmetro do forame apical foi 619,32±32 m para o grupo PV e 630,542±140,99m para o grupo PM sem diferença estatisticamente significante. O diâmetro do canal radicular na junção cemento-dentina não apresentou diferença estatisticamente significante entre PV com 330,37±126,62m e PM com 357,62±996,14m. O posicionamento da JCD em relação ao FM não foi influenciado pelo estado de vitalidade pulpar. / This ex vivo study aimed to investigate the apical anatomy of vital and necrotic human roots by microcomputed tomography (micro-CT). Thirty-five single or multirooted human teeth that had their roots separated totaling forty-one roots were carefully pre-selected and divided into two groups: vital pulp (VP) n = 21 and necrotic pulp (NP) n = 20. Both groups were scanned by microcomputed tomography system (SkyScan 1172) with 6.7m resolution and the apical region was analyzed by reconstructed images in sagittal and coronal sections. The diameters of the apical foramen (AF) and root canal at the cemento-dentino canal junction (CDJ) were measured. The cementum extension into the root canal was measured on both sides of the root canal. Thereafter the teeth crown was cut at the cemento-enamel junction, the length of roots was measured with a caliper and the working length was performed by an electronic apex locator (RomiApex A15). The result of the subtraction of these two data was correlated with measures obtained by micro-CT in the evaluation of CDJ position. The roots were sectioned in longitudinal histological sections of 6m thickness and stained with HE. The sections that showed the emergence of the FA were digitally photographed and the corresponding micro-CT sections were correlated by superimposition in order to illustrate the methodology. Measures of micro-CT scans were performed by two calibrated examiners. The interexaminers agreement was confirmed by intraclass correlation coefficient (ICC) and measurements were compared by Mann-Whitney test (Wilcoxon rank sum test - p0.05). The results indicated that there was no statistically significant difference in relation to the extension of cementum into the root canal in both goups VP or NP with average distances of 0.32±0.1mm and 0.36±0.16mm respectively. The measurements taken by the apex locator 1 mm from the apex were within the limits of dentinal canal. The diameter of the apical foramen corresponded to the NP group was 619.32±201.61m and 619.32±140.99m on average, not statistically significant. The average diameter of the root at the CDJ was 330.37±126.62m for VP and 357.62 ±96.14m for NP groups presenting no statistically significant difference. The distance of the CDJ in relation to AF was not influenced by the pulp vitality.
23

Avaliação do reparo ósseo em osteotomia experimental por microtomografia por raio-X / Fracture healing valuation in experimental osteotomy using X-ray microtomography

Milanetti, Marcia Regina 15 September 2010 (has links)
A microtomografia 3D por raio-X proporciona medidas quantitativas e tridimensionais da estrutura do calo e essas medidas podem potencialmente estar relacionadas com a resistência do calo. A avaliação quantitativa do reparo ósseo por meio de novas metodologias tem importante aplicação nas pesquisas experimentais relacionadas a tecnologias invasivas e não invasivas para a estimulação do mesmo. O objetivo desse estudo foi avaliar o reparo ósseo por meio da \'mü\'CT em defeito ósseo em fêmur de rato. Trinta ratos machos da classe Wistar com peso médio de 300g foram divididos em grupos experimentais de 10 animais em cada grupo. Os animais foram anestesiados e um furo com 1,2 mm de diâmetro foi realizada na porção medial do fêmur utilizando-se uma broca odontológica. No 7º, 14º e 21º pós-cirúrgico, os animais dos grupos experimentais 1, 2 e 3, respectivamente, foram sacrificados e o fêmur esquerdo excisado. Os fêmures foram envolvidos em gaze e mergulhas em solução PBS e armazenados em um saco plástico em freezer a -20º até a análise microtomográfica. Os fêmures foram escaneados pelo microtomógrafo 1172 (SkyScan, Bélgica). Os softwares NRecon, Dataviewer, CT-Analyzer and CT-Vol, fornecidos pelo fabricante do microtomógrafo, foram utilizados para as seguinte análises: a) análise visual das reconstruções microtomográficas dos fêmures através de secções transversais, coronais e sagitais; b) segmentação do calo ósseo nas reconstruções através de algoritmo de processamento de imagem para quantificação dos parâmetros volume total do calo ósseo (TV), volume do calo ósseo mineralizado (BV), relação BV/TV e densidade mineral óssea volumétrica do calo ósseo (BMD); c) visualização 3D do calo ósseo. A análise estatística dos parâmetros medidos utilizou o teste t de Student com um nível de significância p<0,05. Houve um aumento estatisticamente significante nos valores dos parâmetros BV/TV e BMD na comparação entre os grupos experimentais 1 e 2. A comparação entre os grupos 3 e 4 não apresentou significância estatística. Os resultados são coerentes com dados encontrados na literatura sobre a fisiologia óssea, porém o algoritmo de processamento de imagem utilizado necessita aprimoramento em alguns de seus procedimentos para se obter melhor resultado de segmentação do calo ósseo na região de interesse. / X-ray microtomography (uCT) provides quantitative and three dimensional measurements of the callus structure and these measurements could potentially be related to callus strength. The assessment of bone repair through new methodologies has important application in animal investigations regarding invasive or non invasive technologies for the stimulation of bone healing. The aim of this investigation was the use of \'mü\'CT for the assessment of bone repair in a rat femur bone defect. Thirty male Wistar rats weighting about 300g were divided in three experimental groups with 10 animals on each group. The animals were anesthetized and a circular hole with a 1.2 mm diameter was generated at the medial region of the left femur using a dental drill. At the 7th, 14th and 21st day after surgery the animals of experimental groups 1, 2 and 3, respectively, were sacrificed and the left femur excised. The femurs were wrapped in gauze immersed in phosphate-buffered solution and stored in a plastic bag at -20ºC until the analysis by microtomograph. The femurs were scanned by the 1172 microtomograph (SkyScan, Belgium). The softwares NRecon, Dataviewer, CT-Analyzer and CT-Vol, provided by the microtomograph manufacture, were used for the following assessments: a) visual examination of the femurs microtomographic reconstructions using transversal, coronal and sagittal sections; b) segmentation of the bone callus in the reconstructions using an image processing algorithm to quantify the parameters total bone callus volume (TV), volume of the mineralized bone callus (BV), the ratio BV/TV and the volumetric bone callus mineral density (BMD); c) 3D rendering of the bone callus. The statistical analysis of the measured parameters was performed by the Student t test with a level of significance p<0,05. There was a statistically significant increase in the mean values of the parameters BV/TV and BMD in the comparison of experimental groups 1 and 2. The comparison between groups 2 and 3 was not statistically significant. Results are according to bone physiology data from literature although the image processing algorithm used needs some adjustments to get better results in bone callus segmentation in ROI.
24

Patologia comparada das malformações congênitas em Bothrops jararaca e Crotalus durissus provenientes do sudeste brasileiro / Comparative pathology of congenital malformations in Bothrops jararaca and Crotalus durissus from Southeast Brazil

Carvalho, Marcelo Pires Nogueira de 27 June 2014 (has links)
Malformações congênitas, teratogenias ou anomalias do desenvolvimento são processos patológicos definidos como defeitos estruturais que se originam durante a vida embrionária. A ocorrência de teratogenias tem sido relatada em todas as classes de vertebrados e geralmente são incompatíveis com um período de vida prolongado. Uma ampla variedade destas malformações é descrita em répteis, principalmente nas espécies que compreendem a ordem Squamata. Acredita-se que as malformações nestes animais ocorram devido a causas genéticas e/ou ambientais incluindo-se, dentre outras possibilidades, a baixa variabilidade gênica de algumas populações, as alterações de temperatura e umidade ambientais, e a poluição do meio-ambiente. A caracterização e o entendimento dos processos patológicos envolvidos nestas anomalias são de fundamental importância para a compreensão dos fatores que interferem com a conservação dos vertebrados em geral e, no que remete ao presente estudo, das serpentes em específico. Neste contexto, o objetivo desta pesquisa foi caracterizar as alterações macroscópicas e histopatológicas presentes em 102 serpentes acometidas por teratogenias, compreendendo as espécies Bothrops jararaca e Crotalus durissus, correlacionando as alterações histopatológicas identificadas com as malformações. As características macroscópicas das teratogenias foram avaliadas por meio de exames morfométricos, radiográficos, microtomográficos e necroscópicos. Alterações histopatológicas foram identificadas por meio de análise óptica de luz a partir de métodos citoquímicos rotineiros e especiais. O estudo revelou que serpentes da espécie B. jararaca apresentaram lesões axiais mais severas que indivíduos da espécie C. durissus. Nas análises intraespecíficas, fêmeas de C. durissus apresentaram lesões axiais mais severas e em maior número que os machos. No que diz respeito à distribuição destas lesões, indivíduos da espécie C. durissus apresentaram o terço final da coluna, como a região mais acometida pelas malformações axiais. A caracterização microtomográfica de teratogenias específicas (anoftalmia, bicefalia, buftalmia, cauda enrodilhada, ciclopia, cifoescoliose, hidrocefalia, lordose, malformação cefálica e prognatismo), permitiu a análise detalhada destas anomalias e a documentação de alterações morfológicas originais para serpentes como, por exemplo, a agenesia dos ossos frontal, parietal e supraoccipital em B. jararaca portadora de malformação cefálica. A relação entre as alterações histopatológicas e as malformações externas mostrou a existência de correlação estatisticamente significante entre a incidência de doenças renais císticas em serpentes acometidas por braquignatia, quadros inflamatórios oculares em serpentes portadoras de buftalmia, e a desorganização das fibras musculares periaxiais e fusão de corpos vertebrais em serpentes portadoras de lordose. Os dados obtidos constituem uma base de informações úteis para estudos futuros no campo da patologia, teratologia, embriologia e ecotoxicologia em serpentes. / Congenital malformations, developmental abnormalities or teratogeny are pathological processes defined as structural defects that originate during embryonic life. The occurrence of teratogeny has been reported in all classes of vertebrates and is generally incompatible with a prolonged life. A wide variety of these malformations is described in reptiles, especially in species that comprise the Squamata order. It is believed that the defects in these animals occur due to genetic and/or environmental causes including, among other possibilities, the low genetic variability of some populations, changes in environmental temperature and humidity, and environmental pollution. Characterization and understanding of the pathological processes involved in these anomalies are of fundamental importance for the comprehension of factors that interfere with vertebrates conservation in general and, referring to this study, snakes in particular. In this context, the objective of this research was to characterize the macroscopic and histopathological changes present in 102 snakes affected by congenital malformations, comprising the species Bothrops jararaca and Crotalus durissus, correlating histopathological changes with malformations. The macroscopic characteristics of deformities were evaluated by morphometric, radiographic, microtomographic and necropsy analysis. Histopathological changes were identified by light microscopy from routine and special cytochemical methods. The study revealed that B. jararaca snakes had more severe axial lesions than individuals of C. durissus species. In intraspecific analyses, females of C. durissus presented more severe and more numerous axial lesions than males. Regarding lesions distribution, the spinal cord and body final third in individuals of C. durissus species was the region most affected by axial defects. The microtomographic characterization of specific teratogenies (anophthalmia, bicefaly, buphthalmia, curled tail, cyclopia, kyphoscoliosis, hydrocephaly, lordosis, cephalic malformation and prognathism) allowed detailed analysis of these anomalies and the first documentation of certain morphological changes in snakes, for example, agenesis of the frontal, parietal and supraoccipital bones in a B. jararaca presenting cephalic malformation. The relationship between histopathological changes and external malformations showed a statistically significant correlation between the incidence of cystic kidney disease in snakes affected by brachygnatia, ocular inflammatory conditions in snakes affected by buphthalmia, and disorganization of periaxial muscle fibers and fusion of vertebral bodies in snakes presenting lordosis. This research has provided useful and informative data for future studies in the fields of pathology, teratology, embryology and ecotoxicology in snakes.
25

Estudo da anatomia radicular de segundos molares superiores por meio da Microtomografia Computadorizada

Almeida, Marcela Milanezi de 29 May 2013 (has links)
O objetivo deste estudo foi avaliar qualitativa e quantitativamente a anatomia do sistema de canais radiculares de segundos molares superiores por meio de microtomografia computadorizada. Cem dentes foram escaneados no micrótomografo (SkyScan 1174) utilizando uma resolução de 19,7 &#x3BC;m e reconstruídos para análises bidimensionais dos número de canais principais e ramificações, diâmetro maior (V-P) e menor (M-D) a 1, 2, 3, 4 e 5mm do forame apical e área (mm2) das raízes mésio-vestibular, disto-vestibular e palatina. Após a reconstrução tridimensional das amostras escaneadas a classificação do sistema de canais radiculares foi realizada de acordo com Vertucci e os tipos adicionais. Os resultados evidenciaram que nos 2mm apicais iniciais a raiz mésio-vestibular mostrou uma frequência maior do número de canais. O diâmetro maior (V-P) das raízes avaliadas aumentou gradualmente a cada milímetro no sentido ápico-cervical, o diâmetro menor (M-D) das raízes avaliadas diminuiu no segundo milímetro apical, voltando a aumentar a partir deste, a cada milímetro avaliado. A análise tridimensional revelou uma equivalência de dados com relação a classificação de Vertucci, principalmente na raiz palatina e disto-vestibular 98% e em menor escala a raiz mésio-vestibular com 64%. Dentre os tipos de classificações adicionais foram encontrados no presente estudo, 18% dessas classificações para as raízes mésio-vestibulares, 2% para as raízes disto-vestibulares e 1% para a raiz palatina. Este estudo registrou também novos tipos de anatomia, que não se enquadraram nas classificações de Vertucci e nas classificações adicionais dos outros autores: 18% das raízes mésio-vestibulares e 1% da raiz palatina. O presente estudo confirmou por meio do microCT, a alta incidência de canais mésio-palatinos e grande quantidad de ramificações nas raízes mésio-vestibulares nos segundos molares superiores. / The aim of this study was to evaluate qualitatively and quantitatively the anatomy of the root canal system of maxillary second molars using computerized microtomography.One hundred samples were scanned at microCT (SkyScan 1174) using a resolution of 19.7 &#x3BC;m and reconstructed in two-dimensional slices to determine the number of main canals and branches, root canal diameter (B-P) and lower diameter (M-D) direction at 1, 2, 3, 4 and 5mm from the apical foramen. Also, the area (mm2) of the mesiobuccal, distobuccal and palatal roots was analyzed. The classification of the root canal system was performed according to Vertucci and additional authors classifications. The results showed that at the apical third, the mesiobuccal root showed a higher frequency of root canals and ramifications. In overall, the bucco-palatal diameter (B-P) and mesio-distal diameter (M-D) gradually increased from the apical to the cervical third. Threedimensional analysis revealed that 98% of disto-buccal and palatal canals fits in the Vertuccis classification. In the mesiobuccal canal 64% of the anatomies could be described by the Vertucci classification. Other authors classifications were found in 18% of mesiobuccal roots, 2% on distobuccal roots and 1% on palatal roots. This study found new types of root canal anatomies that were not previously described, mainly, in the mesiobuccal and palatal roots (19%). It can be concluded that the mesial buccal roots in maxillary second molars show a higher complexity in comparison to the distobuccal and palatal root.
26

Avaliação, por meio de microtomografia computadorizada, da anatomia interna de incisivos inferiores / Internal anatomy of lower incisors evaluated by computerized microtomography

Leoni, Graziela Bianchi 26 January 2012 (has links)
O conhecimento do sistema de canais radiculares (SCR) é de fundamental importância para o sucesso do tratamento endodôntico. O objetivo deste estudo foi avaliar quantitativa e qualitativamente a anatomia do SCR de incisivos inferiores por meio de microtomografia computadorizada. A aquisição de fotomicrotomografia de 283 incisivos centrais (ICI) e 329 incisivos laterais inferiores (ILI) foi realizada por meio do microtomógrafo SkyScan modelo 1174. Estas imagens foram utilizadas para classificação do SCR de acordo com Vertucci que considera número e localização da divisão dos canais, variando do tipo I ao VIII. Da amostra inicial, 39 ICI e 35 ILI foram escaneados com resolução de 22,9 &mu;m e reconstruídos para análises bidimensionais de: número, área, circularidade, diâmetro maior e menor a 1, 2, 3, 4 e 5 mm do forame apical; e análise tridimensional onde foram observados volume e área de superfície, número e localização de canais acessórios e classificação de acordo com Vertucci. Os resultados evidenciaram que, no terço apical, o número máximo de canais encontrados foi 3; a área aumentou progressivamente a cada milímetro avaliado; a circularidade variou entre 0,37 ± 0,21 (mínimo) e 0,52 ± 0,19 (máximo) demonstrando uma forma achatada destes canais; o diâmetro maior aumentou 95,45% nos ICI e 135,55% nos ILI enquanto o diâmetro menor aumentou 36,36% nos ICI e 66,67% nos ILI. A análise tridimensional revelou que em 76,92% dos ICI e 85,71% dos ILI foi possível a classificação de acordo Vertucci, com maior predominância do tipo I, com canal único, em 46,15% dos ICI e 54,29% dos ILI. Em 15,39% dos ICI e 11,43% de ILI foram identificadas dez novas morfologias. A média do volume (mm3) e da área de superfície (mm2) foram, respectivamente, de 4,38 ± 1,97 e 35,59 ± 11,72 para os ICI e 4,74 ± 1,33 e 38,91 ± 9,56 para os ILI. Os canais acessórios foram observados apenas no terço apical em 46,15% dos ICI e 28,57% dos ILI. Conclui-se que a microtomografia é um método não destrutivo, reprodutível e confiável para estudo de anatomia interna, sendo identificados dez novos tipos morfológicos de SCR de incisivos inferiores. / The knowledge of the root canal system (RCS) is of utmost importance to achieve success in the root canal treatment. The purpose of this study was to evaluate qualitative and quantitatively the RCS anatomy of mandibular incisors by means of microcomputed tomography. The image acquisition of 283 mandibular central incisors (MCI) and 329 mandibular lateral incisors (MLI) was performed using the SkyScan 1174 microtomography device. These images were used to classify the RCS from type I to VIII, considering the number and location of the canals, according to Vertuccis classification. From this sample, thirty-nine MCI and thirty-five MLI were scanned with a resolution of 22.9 &mu;m and reconstructed in order to evaluate the number and location of the main and accessory canals, according to Vertucci\'s classification, the bidimensional parameters of area, roundness, major and minor diameters of the root canal at 1, 2, 3, 4 and 5 mm from the apical foramen, as well as the three-dimensional analysis of volume and surface area. In the apical third, it was found up to three root canals; the area progressively increased from the apical foramen; the roundness ranged from 0.37 ± 0.21 to 0.52 ± 0.19 demonstrating the flat-oval shape of the canals; the major and minor diameters increased 95.45% and 36.36% in the MCI and 135.55% and 66.67% in the MLI, respectively. The threedimensional analysis revealed that in 76.92% of MCI and 85.71% of MLI the RCS could be classified according to Vertucci\'s, and type I (one root canal) was found in 46.15% and 54.29% of MCI and MLI, respectively. Ten new types of root canal morphologies were observed in 15.39% of MCI and 11.43% of MLI. The mean volume (mm3) and surface area (mm2) were 4.38 ± 1.97 and 35.59 ± 11.72 in the MCI, and 4.74 ± 1.33 and 38.91 ± 9.56 in the MLI, respectively. Accessory canals were observed only in the apical third in 46.15% of MCI and 28.57% of MLI. It was concluded that the microtomography is a non-destructive, reproducible and reliable method for the study of the RCS that allowed the identification of ten new types of root canal morphologies in mandibular incisors.
27

Estudo imaginológico da regeneração óssea guiada associada ou não à terapia de fotobiomodulação (PBMT) em ratas com osteoporose / Imaging study of guided bone regeneration associated or not with photobiomodulation therapy (PBMT) in rats with osteoporosis

Alves, Fernando Amorim Mendonça 14 September 2018 (has links)
A osteoporose é uma doença sistêmica caracterizada pela perda de conteúdo mineral do osso propiciando fraturas críticas. A regeneração óssea guiada e a terapia de fotobiomodulação (PBMT do inglês photobiomodulation therapy) favorecem a regeneração óssea. O objetivo do estudo foi avaliar o efeito da PBMT no reparação óssea guiada de lesões críticas de 36 ratas com osteoporose induzida por ooforectomia. Foram realizadas lesões ósseas estandardizadas nos ossos parietais e então tratadas de acordo com os seguintes grupos experimentais (n=12 lesões por grupo): Controle: sem tratamento adicional; Membrana - Colocação de uma membrana de colágeno suíno comercial (Bio-Gide®) dentro do leito cirúrgico; PBMT1- membrana e aplicação da PBMT1; PBMT2- membrana e aplicação da PBMT2. A PBMT foi realizada com laser de diodo infravermelho no modo contínuo, pontual e em contato (808nm, 40mW, 1,42W/cm2; PBMT1: 3s, 4J/cm2, 0,12J por ponto e PBMT2: 10s, 14J/cm2, 0,4J por ponto) imediatamente, 48 e 96 horas após a cirurgia. Quatro e oito semanas após a cirurgia os animais foram eutanasiados, a calota craniana dissecada, fixada e submetida à análise por microtomografia computadorizada. Foram coletados os seguintes dados: volume ósseo relativo (razão entre o volume ósseo e o volume total), número, espessura e separação de trabéculas, conectividade por densidade e índice de estrutura de modelo (SMI do inglês structure model index). Os dados de cada análise foram comparados pelo teste ANOVA dois critérios/Tukey ou Kruskal Wallis/Dunn e os dados de análises diferentes pelo teste de correlação de Spearman (p<0,05). Diferenças significativas foram observadas em 8 semanas. A PBMT, em especial nos parâmetros de menor energia (0,12J), acelerou o reparo ósseo resultando na obtenção de maior volume ósseo, com grande número de trabéculas, de espessura média, próximas e interconectadas e com valores baixos de SMI. Dentro das limitações deste trabalho in vivo, concluímos que a PBMT acelera a formação e maturação do tecido ósseo neoformado em lesões ósseas críticas de ratas osteoporóticas. / Osteoporosis is a systemic disease characterized by loss of bone mineral content leading to critical fractures. Guided bone regeneration and photobiomodulation therapy (PBMT) favor bone regeneration. The objective of the study was to evaluate the effect of PBMT on the guided bone repair of critical lesions of 36 rats with osteoporosis induced by oophorectomy. Standardized bone lesions were performed on the parietal bones and then treated according to the following experimental groups (n = 12 lesions per group): Control: no additional treatment; Membrane - Placement of a commercial swine collagen membrane (Bio-Gide®) within the surgical bed; PBMT1 membrane and PBMT1 application; PBMT2-membrane and PBMT2 application. PBMT was performed with continuous wave infrared diode lasers in punctual and contact mode (808nm, 40mW, 1.42W / cm2, PBMT1: 3s, 4J / cm2, 0,12J per ponit and PBMT2: 10s, 14J / cm2, 0.4J per point) immediately, 48 and 96 hours after surgery. Four and eight weeks after surgery, the animals were euthanized, the skulls dissected, fixed and submitted to the analysis by computerized microtomography. The following data were collected: bone volume, relative bone volume (ratio of bone volume to total volume), number, thickness and separation of trabeculae, density connectivity and model structure index (SMI). The data from each analysis were compared using the ANOVA two criteria / Tukey or Kruskal Wallis / Dunn test and the different analysis data by the Spearman correlation test (p <0.05). Significant differences were observed at 8 weeks. PBMT, especially in the lower energy parameters (0.12J), accelerated bone repair resulting in higher bone volume, with a large number of trabeculae, medium thickness, close to each other and interconnected, and with low SMI values. Within the limitations of this in vivo study, we concluded that PBMT accelerates the formation and maturation of neoformed bone tissue in critical bone lesions of osteoporotic rats.
28

Avaliação do reparo tecidual em defeito ósseo por microtomografia tridimensional por raio X / Evaluation of tissue repair after bone fracture using 3D X-ray microtomography

Introini, Simone Orlandi 01 July 2011 (has links)
A fratura é uma descontinuidade óssea que pode ser produzida cirurgicamente ou causada por um impacto que excede a resistência mecânica do osso dando início a uma sequência de eventos sistêmicos e específicos de resposta do tecido. Exames radiológicos são comumente realizados na clínica e em experimentos com animais para o monitoramento do reparo ósseo dando informações sobre o alinhamento dos fragmentos e da evolução de reparo. Outras técnicas de monitoramento qualitativas e quantitativas podem ser utilizadas em experimento animal (histologia e ensaios mecânicos) e em experimento animal e clínico (tomografia computadorizada por raio X, ressonância magnética, ultra-sonografia). A microtomografia 3D por raio X é uma nova técnica de monitoramento para uso em experimento animal e com grande potencialidade. A quantificação do reparo ósseo com novas metodologias tem larga aplicação em investigações sobre técnicas invasivas e não-invasivas de tratamento de fraturas utilizando-se experimento animal. O objetivo dessa investigação foi a utilização da microtomografia 3D por raio X policromático (\'mü\'CT) para a avaliação do reparo ósseo em defeito ósseo na tíbia direita de rato macho da raça Wistar com peso aproximado de 280 g. O defeito foi produzido por uma broca odontológica com alta rotação. Foram estabelecidos quatro grupos experimentais caracterizados pela utilização ou não utilização do tratamento do defeito por ultra-som pulsado de baixa intensidade (LIPUS, 30 mW/\'CM POT.2\') e pela duração do experimento. No grupo 1 o tratamento por ultra-som teve a duração de 14 dias, 5 sessões de tratamento por semana. No grupo 2 não houve tratamento por ultra-som e a duração foi de 14 dias. No grupo 3 o tratamento por ultra-som teve a duração de 21 dias, 5 sessões de tratamento por semana. No grupo 4 não houve tratamento por ultra-som e a duração foi de 21 dias. Nos grupos 1 a 4 foram utilizados 10 animais para a avaliação por CT. O defeito ósseo da tíbia direita nos animais dos grupos 1 e 3 foi tratado com ultra-som de baixa intensidade. A avaliação por CT foi realizada através dos softwares NRecon, Data Viewer , CT-Analyzer e CT-Vol fornecidos pelo fabricante do microtomógrafo (Skyscan, Bélgica). Não foi observada diferença estatísticamente significante na quantificação do reparo ósseo dos defeitos dos grupos 1 e 2 e dos grupos 3 e 4. / Fracture is a bone discontinuity that can be surgically produced or caused by an impact that exceeds the mechanical strength of bone by initiating a series of systemic events and specific tissue response. Radiological tests are commonly performed in clinical and animal experiments for monitoring the bone healing by providing information about the alignment of the fragments and the evolution of repair. Other techniques for monitoring quality and quantity can be used in experimental animals (histology and mechanical tests) and in animal experiments and clinical studies (computed tomography X-ray, MRI, ultrasound). The 3D microtomography by X-ray is a new monitoring technique for use in animal experiment and with great potential. The quantification of bone repair with new methods has wide application in research on invasive and noninvasive treatment of fractures using animal experiment. The goal of this research was to use the 3D microtomography by non monochromatic X-ray (\'mü\'CT) to evaluate the bone healing in bone defect in the tibia of Wistar male rat weighing approximately 280 g. The defect was produced by a dental drill with high speed. It was established four experimental groups characterized by the use or non use of low intensity pulsed ultrasound (LIPUS, 30 mW/\'CM POT.2\') for the bone defect treatment as well as the duration of the experiment. In group 1 the LIPUS treatment last 14 days, 5 treatment sessions per week. In group 2 the LIPUS treatment was not used and the duration was 14 days. In group 3 the LIPUS treatment last 21 days, 5 treatment sessions per week. In group 4 the LIPUS treatment was not used and the duration was 21 days. In groups 1 to 4, 10 animals were used for evaluation by CT. The evaluation was conducted by CT through software NRecon, Data Viewer, CT-Vol and CT-Analyzer supplied by the microtomography manufacturer (SkyScan, Belgium). No significant statistical differences were found between the results of groups 1 and 2 as well as the results of groups 3 and 4.
29

Comparação do transporte, centralização e extrusão apical de detritos após o uso de sistemas de NiTi em canais radiculares curvos

Boijink, Daiana January 2018 (has links)
Introdução: Os objetivos do presente estudo foram comparar a extrusão apical de detritos durante o preparo apical #25 com os sistemas Twisted File Adaptive (TFA), WaveOne Gold (WOG) e técnica manual (TM), registrar o tempo de preparo; e comparar WOG com TFA em relação ao transporte do canal radicular (TCR) e centralização (CR) com diâmetros apicais #25 e #35. Metodologia: Quarenta e cinco canais mésio-vestibulares de molares inferiores foram preparados e divididos em 3 grupos (n=15) para avaliar extrusão apical. A extrusão de detritos foi quantificada subtraindo-se o peso final do peso inicial dos tubos Eppendorf. TCR e CR foram avaliados em micro-TC com os sistemas TFA e WOG (n=15). A normalidade dos valores obtidos para cada grupo foi verificada usando teste de Kolmogorov-Smirnov. Para quantificar detritos extruídos e tempo de preparo, os dados foram paramétricos, sendo utilizado o Teste ANOVA de 1 via e post hoc de Tukey’s. Para avaliar TCR e CR, o teste estatístico foi Mann Whitney e Wilcoxon (α=.05). Resultados: Em relação aos detritos, o sistema WOG foi associado com menos extrusão em comparação com TM (P<0,05) ou com o sistema TFA (P> 0,05). O tempo de preparo exigido pela TM foi significativamente maior do que o exigido pelas outras técnicas (P<0,05). Não foram encontradas diferenças estatisticamente significantes entre WOG e TFA em relação à centralização em todos os níveis, quando usado diâmetro apical #25 ou #35 (P> 0,05). Para TCR, diferença significativa foi encontrada entre TFA e WOG a 1 e 7mm com diâmetro apical #25 e #35 (P<0,05). Foi encontrada diferença significante para TFA em 4mm, quando os diâmetros apicais #25 e #35 foram avaliados no mesmo sistema (P <0,05). Conclusões: Todos os sistemas de instrumentação causaram extrusão de detritos apicais em algum grau. TFA e WOG podem ser usados em canais radiculares curvos com segurança com diâmetros apicais# 25 ou 35. / Introduction: The aims of this study were to assess the amount of apically debris during root canal preparation with apical size #25 with the Twisted File Adaptive system (TFA), WaveOne Gold system (WOG) and manual technique (MT), and recorded working time; and to assess WOG with TFA in relation to root canal transportation (RCT) and centering ratio (CR) with apical diameters # 25 and # 35. Methods: Forty-five mesiobuccal root canals of mandibular molars were prepared and assigned into 3 groups (n = 15) to evaluate apical extrusion. Debris extrusion was quantified by subtracting the final from the initial weight of the Eppendorf tubes. RCT and CR were evaluated in Micro-TC with the TFA and WOG systems (n = 15). The normality values obtained for each group were tested using the Kolmogorov-Smirnov test. To quantify extruded debris and preparation time, the data were parametric, using the Tukey's 1-way and post-hoc ANOVA test. To evaluate RCT and CR, the statistical test was Mann Whitney (α =.05). Results: The WaveOne Gold reciprocating single-file system was associated with less extrusion of debris compared with hand files (P < 0.05) or with the Twisted File Adaptive system (P > 0.05). The preparation time required by hand files was significantly longer than that required by the other techniques (P < 0.05). No significant differences were found between WOG and TFA regarding CR for all levels when used #25 or #35 apical size preparation (p>0.05). For RCT, significant difference was found among TFA and WOG at 1 mm and 7 mm with diameter apical #25 and #35. (p<0.05). Statistically different for the TFA in 4 mm was observed when the apical diameters # 25 and # 35 was evaluated in the same system (P <0,05). Conclusions: All of the instrumentation systems caused apical debris extrusion to some degrees. TFA and WOG can be used in curved root canals with safety with #25 or 35 apical diameters.
30

Avaliação da estabilidade inicial de implantes instalados em modelos ósseos suínos padronizados em posicionamentos ao nível ou infraósseos / Evaluation of implants placed in bone standardized pig models in positions bone level or intraosseous using biomechanical tests and Micro-CT. An in vitro pilot study

Jessica Pires de Carvalho 25 August 2016 (has links)
A estabilidade primária é decorrente da adaptação mecânica imediata entre o osso e o implante após a sua inserção. O sucesso desta adaptação depende de fatores como a densidade e qualidade ósseas, tamanho, diâmetro, forma e rugosidade da superfície do implante. As cargas oclusais aplicadas sobre o implante podem afetar o osso circundante. Esse estudo teve como objetivo avaliar, comparativamente, a estabilidade inicial de implantes ósseo inseridos em cilindros de osso suíno padronizados, em diferentes posicionamentos ósseos, com e sem a aplicação de carga, por meio de análises de imagens tridimensionais (microtomografia computadorizada) e análises mecânicas (Frequência de ressonância, Torque de inserção e Ensaio de arrancamento). Os cilindros ósseos foram preparados a partir de osso suíno e separados em 2 grupos conforme a área doadora: Grupo A: cilindros removidos da cabeça do fêmur (alta densidade óssea) e Grupo B: cilindros removidos do côndilo mandibular (baixa densidade óssea). Previamente aos procedimentos experimentais, os cilindros ósseos foram certificados através de análises de imagens 2D (radiografia digital), para garantir a uniformidade intra-grupos e distinção entre os grupos dos espécimes. Após a certificação, foram feitas microtomografias computadorizadas dos cilindros ósseos para análise tridimensional de imagens prévia à instalação dos implantes, avaliando os seguintes parâmetros: porcentagem de volume ósseo (BV/TV), separação trabecular (TbSp), razão entre a medida da área superficial do osso e o seu volume ósseo (BS/BV) e porcentagem de porosidade total (POTOT). Depois disso, foram selecionados 60 implantes, que foram divididos em 4 grupos, cada um com 15 implantes: G1 (cilindros ósseos de alta densidade com implante situados ao nível ósseo), G2 (cilindros ósseos de alta densidade com implante 2 mm infraósseo), G3 (cilindros ósseos de baixa densidade com implante ao nível ósseo) e G4 (cilindros de baixa densidade com implante 2 mm infraósseo). A instalação dos implantes seguiu o protocolo recomendado pelo fabricante e durante o procedimento foi realizada a medida do torque de inserção. Após a instalação dos implantes, os cilindros ósseos foram submetidos à nova análise tridimensional (com avaliação dos mesmos parâmetros anteriores, nas áreas intra-roscas e adjacente à estas, acrescidos da medida da área de contato ossoimplante (BIC). Foi então realizada a avaliação do Coeficiente de Estabilidade (ISQ), utilizando a análise de frequência de ressonância (Osstell®). Após essa avaliação, 5 implantes de cada grupo foram submetidos ao ensaio de arrancamento. Os 10 implantes de cada grupo restantes foram conectados a pilares protéticos adequados, os quais receberam uma aplicação de forças axial (G1, G2, G3 e G4, 5 implantes de cada grupo) e lateral (G1, G2, G3 e G4, 5 implantes de cada grupo). Após aplicação das forças, os cilindros ósseos foram submetidos a nova análise tridimensional com avaliação dos mesmos parâmetros descritos, a nova análise de frequência de ressonância e ao ensaio de arrancamento. As variáveis foram testadas em relação à normalidade dos dados. Para todas as análises foi considerado um nível de significância de 5%. As análises estatísticas foram realizadas com base nos dados absolutos obtidos durante a análise tridimensional em cada situação de carga (antes do implante, pósimplante e pós-carga) e com a variação entre os valores das situações pós-implante e póscarga (variação carga - implante). A avaliação estatística do parâmetro de análise de frequência de ressonância não encontrou diferenças estatisticamente significantes para as comparações entre grupos G1 versus G3 e G2 versus G4 nas avaliações pós implante e pós carga. Em relação ao torque de inserção, houve diferenças estatisticamente significantes para as comparações entre grupos com implantes instalados no mesmo nível G1 versus G3 e G2 versus G4. Os maiores valores de torque de inserção obtidos foram registrados nos grupos de alta densidade. A análise estatística do ensaio de arrancamento mostrou diferenças estatisticamente significantes para as comparações: G1 versus G3 (inicial) e G1 versus G4 (inicial). Após a aplicação de carga oclusal, pode-se constatar diferenças estatisticamente significantes para as comparações: G1 versus G3 e G2 versus G4, após aplicação de carga lateral a análise mostrou diferença estatisticamente significante para a comparação G3 versus G4. Os resultados das análises tridimensionais mostraram diferenças estatisticamente significantes para os parâmetros TbSp e POTOT na avaliação da área óssea intra-rosca. A avaliação dos dados de variação após a aplicação de carga oclusal e lateral para o parâmetro TbSp, mostrou diferenças estatisticamente significantes para as comparações G2 versus G4. Em relação ao parâmetro POTOT, a aplicação de carga oclusal e lateral mostrou diferença estatisticamente significante para as análises: G1 versus G2 e G2 versus G4. Em relação ao parâmetro BSBV a análise dos valores absolutos, mostrou diferenças estatisticamente significantes para a área óssea intra-rosca dos grupos de baixa densidade. Já a análise dos valores de variação, a aplicação de carga oclusal mostrou diferenças estatisticamente significantes para os grupos G1 versus G3, G2 versus G4 e G3 versus G4, enquanto a aplicação de carga não axial resultou em diferenças estatisticamente significantes para os grupos G3 versus G4 e G2 versus G4. Já a análise estatística dos dados de variação do parâmetro BV/TV, mostrou diferença estatisticamente significante para todas as comparações na área óssea intra-rosca após aplicação de carga oclusal e lateral. A análise estatística do parâmetro BIC mostrou diferenças significantes para os grupos de baixa densidade (G3 e G4) nas comparações pós implante e pós carga. Em relação aos dados de variação, pode-se constatar diferença estatisticamente significante na aplicação de carga axial para G1 versus G2 e G2 versus G4, enquanto a aplicação de carga lateral mostrou diferença estatisticamente significante para as comparações G1 versus G3 e G2 versus G4. De acordo com os dados obtidos pode-se concluir que a densidade óssea tem relação com a estabilidade primária de implantes, que cargas não axias são prejudiciais para o tecido ósseo peri-implantar e que o posicionamento infraósseo pode promover melhor resposta do tecido ósseo, principalmente em regiões de baixa densidade óssea. / With the increase of oral rehabilitation with implants, immediate load can be used to reduce the treatment time. It is important to perform correct treatment planning for immediate implant loading, using 3D image analysis. The subcrestal implant positioning is one of the possible factors that may impact the success of immediate loading implants. Objective: The aim of this study is to evaluate the initial stability of osseointegrated implants placed infra bone or at the bone level in standardized porcine bone cylinders, through image (microcomputerized tomography) and mechanical analysis (resonance frequency, insertion torque and pull out test). Sixty bone cylinders were prepared from fresh porcine bone and separated in 2 groups: Group A 30 cylinders removed from femur head (high bone density) and Group B - 30 cylinders removed from the mandibular condyle (low bone density). Before the experimental procedure, the bone cylinders were certificated through 2D images analysis (digital radiography) to calculated bone density. After this, the bone cylinders were evaluated through micro computed three-dimensional analysis before the implant insertion. The parameters were analyzed in 2 levels (L1-bone volume internal to the threads and L2 - immediately adjacent to the end of threads). The microtomographical parameters analyzed were: Bone volume/Total volume (BV/TV), Trabecular thickness (TbSp), Bone surface/Volume ratio (BS/BV) and Total porosity percent (POTOT). Then, 60 implants (Alvim, 3.5 mm x 10 mm, Neodent®, Curitiba) were inserted in bone cylinders (1 implant in each cylinder), according to manufacturers protocol, and insertion torque was recorded for each implant. After that, the bone cylinders were submitted a new micro computed tomography analysis that evaluated the same levels and parameters, and Bone Implant Contact (BIC) was also recorded. After that, 5 implants were submitted to pull out test while the others implants received axial and non- axial load. After that, a new microcomputerized tomography analysis evaluated the same levels and parameters previously described, and resonance frequency analysis and pullout test were performed in the bone cylinders. 3D analysis showed that pre- and post-implants intra-groups had statistically significant differences for TbSp and POTOT parameters, and for BSBV and BIC parameters there were observed statistically significant differences for low bone densities groups. The values of differences between post and before loading showed statistically significant differences between G2 and G4 for TbSp, POTOT, BSBV, BV/TV and BIC parameters. The RFA analysis showed highest values for G2 and G4. Concerning insertion torque, the highest mean values were found in high bone densities groups. The pullout strength test showed that the non- axial loads in the low bone density maybe lead to implant displacement throughout the implant insertion axis. Bone density has a direct relationship with implant primary stability. Non- axial loads are harmful to peri- implantar bone tissue and subcrestal placement of implants presented the best mechanical and tomographical results.

Page generated in 0.4391 seconds