• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 32
  • 1
  • Tagged with
  • 33
  • 33
  • 28
  • 27
  • 27
  • 26
  • 17
  • 15
  • 11
  • 11
  • 11
  • 9
  • 9
  • 8
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Desenvolvimento de um equipamento portátil e de sistema de análises em fluxo empregando multicomutação. Determinação fotométrica de ferro em águas de rios / Development of a portable equipment and a flow analysis system employing multicommutation. Photometric determination of iron in river waters

Jeová Correia Miranda 20 July 2011 (has links)
O ferro é o elemento mais abundante na Terra e tem importante papel em ciclos biogeoquímicos Neste trabalho foi desenvolvido um procedimento analítico automático para a determinação fotométrica de ferro em águas de rios, empregando um fotômetro baseado em LED e mini-bombas solenoide para o gerenciamento de soluções. O procedimento proposto foi baseado na reação do ferro (III) com o tiocianato de potássio formando um complexo avermelhado com máximo de absorção em 470 nm. Para a determinação de ferro total foi incluída uma etapa de oxidação em linha, usando uma solução de persulfato (S2O82-) como oxidante. O módulo de análises foi constituído por quatro mini-bombas solenoide e uma válvula solenoide de três vias. Para a obtenção de sinais foi construído um fotômetro composto por uma cela de fluxo com caminho óptico de 50 mm, um LED azul (\'lâmbda\'=470 nm) e um fotodetector. Visando utilizar este equipamento portátil para medidas em campo, foram empregadas duas baterias de 6 V para alimentar os dispositivos ativos. Os ensaios em laboratório mostraram que as baterias permitem uma autonomia de mais de 50 horas de trabalho sem recarregá-las. O procedimento desenvolvido apresentou as seguintes características analíticas: resposta linear entre as concentrações de 0,25 e 4,0 mg L-1, segundo a equação Y = (0,0183 ± 0,003) + (0,15326 ± 0,002)X (r=0,9997); limite de detecção 0,013 mg L-1 Fe (III) estimado com 99,7 % de confiança; desvio padrão relativo estimado em 0,95 % (n=15) obtido com uma solução de concentração de 1,5 mg L-1 Fe (III); frequência de amostragem de 50 determinações por hora. Os resultados obtidos pelo procedimento proposto e pelo de referência não apresentaram diferenças significativas com nível de confiança de 95 % / Iron is the most abundant element on Earth and plays an important role in biogeochemical cycles. In this work, an automatic analytical procedure was developed for the photometric determination of iron in river waters, employing a LED-based photometer and solenoid mini-pumps for solution handling. The proposed procedure was based on the reaction between iron (III) and potassium thiocyanate, yielding a red complex with maximum absorption at 470 nm. For the determination of total iron, an in line oxidation step was included, employing a persulfate solution (S2O82-) as oxidant. The module was constructed with four solenoid mini-pumps and a three-way solenoid valve. For data acquisition a photometer was constructed with a 50 mm optical path flow cell, a blue LED (\'lâmbda\'= 470 nm) and a photodetector. Envisioning the use of this portable equipment in field, two 6-Volt batteries were employed to supply energy to the active devices. Laboratory tests showed that the batteries provide more than 50 hours of operation without recharging. The proposed procedure showed the following analytical features: linear response between 0.25 and 4.0 mg L-1, according to the equation Y = (0.0183 ± 0.003) + (0.15326 ± 0.002) X (r = 0.9997); detection limit of 0.013 mg L-1 Fe (III), estimated with 99.7 % of confidence; relative standard deviation estimated as 0.95% (n = 15), obtained with a 1.5 mg L-1 Fe (III) solution; sampling rate of 50 determinations per hour.The results obtained with the proposed and reference procedure did not show significative differences at a 95% confidence level
32

Desempenho de sistemas de extração e análises em fluxo explorando fluxo pulsado e leito fluidizado / Performance of extraction systems and flow analysis exploring pulsed flow and fluidized bed

Andrino, Jeane Maria Cunha Machado 28 April 2017 (has links)
O emprego de sistemas em fluxo com multi-impulsão são destaques quanto ao volume de efluentes gerados e a possibilidade de mecanização, operando em condições dinâmicas. A utilização de microbombas solenoide é potencial em processos de adsorção/dessorção de analitos, pois desempenham o fluxo pulsado, e quando operadas em conjunto com o estabelecimento da condição de leito fluidizado, contribuem para o aumento da eficiência de adsorção/dessorção. O objetivo geral deste trabalho foi desenvolver e avaliar sistemas de extração sólido-líquido e análises química em fluxo, explorando fluxos pulsados e o estabelecimento da condição de leito fluidizado, visando melhorar a eficiência de interação da amostra e reagente. Para tanto, foram desenvolvidos sistemas em fluxo com multi-impulsão associados ao uso de colunas de leito fluidizado. 1) Sistema para determinação da capacidade de adsorção de fósforo; determinação do fósforo remanescente (P-rem) em solos; 2) Sistema para determinação da capacidade de troca catiônica (CTC) de solos, avaliando a adsorção e a dessorção de analitos. Foi demonstrado que o fósforo e o cálcio contidos em solução são eficientemente adsorvidos/dessorvidos pelo solo, reduzindo significativamente os efeitos de aumento de pressão com o estabelecimento do leito fluidizado (fluidização pulsada) nas colunas contendo 50 mg de amostras de solo. A substituição do fluxo pulsado (microbomba solenoide) pelo fluxo contínuo (bomba peristáltica) limitou a interação sólido-líquido, pois estabeleceu caminhos preferenciais, desfavorecendo as condições de mistura. A utilização das microbombas solenoide em conjunto com a fluidização das amostras de solo, apresentou vantagens quanto à diminuição da quantidade de massa de solo requerida (entre 100 e 200 vezes), redução do consumo de reagentes e resíduos gerados (40 vezes), demonstrando o potencial do sistema em fluxo proposto por ser uma alternativa ambientalmente adequada. Os sistemas propostos são versáteis e facilmente adaptados para outros estudos de extração / Multi-pumping flow systems are highlights on the volume of effluents generated and mechanization, operating in dynamic conditions. Solenoid micro-pumps are potential in the analyte adsorption/desorption processes, because they play the pulsed flow and when operated in conjunction with the establishment of the fluidized bed condition, contribute to the increase of the adsorption/desorption efficiency. The objective of this work was to develop and evaluate solid-liquid extraction and flow analysis systems, exploring pulsed flows and establishing the fluidized bed condition in order to improve the solid-liquid interaction efficiency. It was developed multi-pumping flow systems associated with the establishment of the fluidized bed columns. 1) System for determination of phosphorus adsorption capacity; determination of the remaining phosphorus (P-rem) in soils; 2) System to determine the cation exchange capacity (CEC) of soils, evaluating the adsorption and desorption of analyte. It has been shown that the phosphorus and calcium contained in solution are efficiently adsorbed/desorbed by the soil, significantly reducing the effects of pressure increase with the establishment of the fluidized bed (pulsed fluidization) in the columns containing 50 mg of soil samples. The substitution of the pulsed flow (solenoid micro-pump) by the continuous flow (peristaltic pump) limited the solid-liquid interaction, since it established preferential pathways, undermining the mixing conditions. The use of the solenoid micro-pumps in conjunction with the fluidization of the soil samples presented advantages in terms of decreasing the amount of soil mass required (between 100 and 200-fold time), reducing the consumption of reagents, solutions and waste production (40-fold time), demonstrating the potential of this system to be an environmentally friendly alternative. The proposed systems are versatile and easily adapted to other extraction studies
33

Desempenho de sistemas de extração e análises em fluxo explorando fluxo pulsado e leito fluidizado / Performance of extraction systems and flow analysis exploring pulsed flow and fluidized bed

Jeane Maria Cunha Machado Andrino 28 April 2017 (has links)
O emprego de sistemas em fluxo com multi-impulsão são destaques quanto ao volume de efluentes gerados e a possibilidade de mecanização, operando em condições dinâmicas. A utilização de microbombas solenoide é potencial em processos de adsorção/dessorção de analitos, pois desempenham o fluxo pulsado, e quando operadas em conjunto com o estabelecimento da condição de leito fluidizado, contribuem para o aumento da eficiência de adsorção/dessorção. O objetivo geral deste trabalho foi desenvolver e avaliar sistemas de extração sólido-líquido e análises química em fluxo, explorando fluxos pulsados e o estabelecimento da condição de leito fluidizado, visando melhorar a eficiência de interação da amostra e reagente. Para tanto, foram desenvolvidos sistemas em fluxo com multi-impulsão associados ao uso de colunas de leito fluidizado. 1) Sistema para determinação da capacidade de adsorção de fósforo; determinação do fósforo remanescente (P-rem) em solos; 2) Sistema para determinação da capacidade de troca catiônica (CTC) de solos, avaliando a adsorção e a dessorção de analitos. Foi demonstrado que o fósforo e o cálcio contidos em solução são eficientemente adsorvidos/dessorvidos pelo solo, reduzindo significativamente os efeitos de aumento de pressão com o estabelecimento do leito fluidizado (fluidização pulsada) nas colunas contendo 50 mg de amostras de solo. A substituição do fluxo pulsado (microbomba solenoide) pelo fluxo contínuo (bomba peristáltica) limitou a interação sólido-líquido, pois estabeleceu caminhos preferenciais, desfavorecendo as condições de mistura. A utilização das microbombas solenoide em conjunto com a fluidização das amostras de solo, apresentou vantagens quanto à diminuição da quantidade de massa de solo requerida (entre 100 e 200 vezes), redução do consumo de reagentes e resíduos gerados (40 vezes), demonstrando o potencial do sistema em fluxo proposto por ser uma alternativa ambientalmente adequada. Os sistemas propostos são versáteis e facilmente adaptados para outros estudos de extração / Multi-pumping flow systems are highlights on the volume of effluents generated and mechanization, operating in dynamic conditions. Solenoid micro-pumps are potential in the analyte adsorption/desorption processes, because they play the pulsed flow and when operated in conjunction with the establishment of the fluidized bed condition, contribute to the increase of the adsorption/desorption efficiency. The objective of this work was to develop and evaluate solid-liquid extraction and flow analysis systems, exploring pulsed flows and establishing the fluidized bed condition in order to improve the solid-liquid interaction efficiency. It was developed multi-pumping flow systems associated with the establishment of the fluidized bed columns. 1) System for determination of phosphorus adsorption capacity; determination of the remaining phosphorus (P-rem) in soils; 2) System to determine the cation exchange capacity (CEC) of soils, evaluating the adsorption and desorption of analyte. It has been shown that the phosphorus and calcium contained in solution are efficiently adsorbed/desorbed by the soil, significantly reducing the effects of pressure increase with the establishment of the fluidized bed (pulsed fluidization) in the columns containing 50 mg of soil samples. The substitution of the pulsed flow (solenoid micro-pump) by the continuous flow (peristaltic pump) limited the solid-liquid interaction, since it established preferential pathways, undermining the mixing conditions. The use of the solenoid micro-pumps in conjunction with the fluidization of the soil samples presented advantages in terms of decreasing the amount of soil mass required (between 100 and 200-fold time), reducing the consumption of reagents, solutions and waste production (40-fold time), demonstrating the potential of this system to be an environmentally friendly alternative. The proposed systems are versatile and easily adapted to other extraction studies

Page generated in 0.0901 seconds