• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 32
  • 1
  • Tagged with
  • 33
  • 33
  • 28
  • 27
  • 27
  • 26
  • 17
  • 15
  • 11
  • 11
  • 11
  • 9
  • 9
  • 8
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

EMPREGO DE MULTICOMUTAÇÃO NA AUTOMATIZAÇÃO DO MÉTODO SPADNS PARA DETERMINAÇÃO DE FLUORETO EM ÁGUAS / EMPLOYMENT OF MULTICOMMUTATION IN THE AUTOMATION OF THE SPADNS METHOD FOR DETERMINATION OF FLUORIDE IN WATERS

Lima, Anderson de Jesus Dias 18 December 2013 (has links)
Made available in DSpace on 2016-08-19T12:56:42Z (GMT). No. of bitstreams: 1 dissertacao Anderson.pdf: 1077270 bytes, checksum: c2961e1f0addb43e445ceff8377bb094 (MD5) Previous issue date: 2013-12-18 / The benefits the fluorine offers to the humans, mostly in reducion of solubility and remineralization of tooth covering, especially, when it is used in the water for consumption, bringing out a large extension, and also its significance in the floculation process on natural water, ensures the necessity of its quantification, aggregates to the current trend of wastes low production determination techniques. In this investigation, it was developed an computerized system based on flow injection system analysis, utilizing the conception of multicommutation for determination of fluoride in water, that permitted several steps of the analytical procedure where they were done without the operator intervention. The analysis module was developed taking into account the chemical reaction characteristics involved in the analysis of fluorides in water by the SPADNS method. For optimization of the system purposed, studies of opening time of solenoid valves, reactor length, flow rate, cycle numbers, SPADNS concentration, ZrOCl2.8H2O and effect of NaAsO2 were done in the analytical signal, which, respectively, presented values considered great of 0.1 s insertion valve in the indicator mixture and 0.5 s sample insertion valve, 75 cm, 2.8 mL.min-1, 8 cycles, 3.36 x 10-3 mol.L-1 and 1.66 x 10-3 mol.L-1, did does not present relevant difference in the analytical signal when the use of NaAsO2 for the disposal of residual chlorine. The system has provided a wider zone of linear answer (0.4 to 1.6 mg.L-1 fluoride) when salt of zircon had been utilized in a concentration 1.66 x 10-3 mol.L-1 for curve of calibration y = 0.004 + 0.13675 x, r = 0.999, detection limit (LD) and quantification limit (LQ) estimated in 0.019 mg.L-1 and 0.066 mg.L-1, respectively, to the assurance level of 99.7%, for n = 4 and standard deviation 0.00107, showing, therefore, repetitive and precise, despite it presents low consumption of reagent (37 μL of indicator mixture include in 2.3 mL of total remainder per replica) and good analytical frequency of 68 determination per hour. In a comparison of methods, the test t of Student has not presented relevant difference, once the tcal. = 1.840 for samples of supplying water and tcal. = 1.017 for samples of mineral water were smaller than ttab. = 2.776 for n = 5 (n - 1 = 4 freedom degrees) in an assurance level of 95%. The recovery test, overall, has verified a good fit to the method proposed. / Os benefícios que o flúor proporciona ao ser humano, principalmente na redução da solubilidade e aumento da remineralização do esmalte dos dentes, sobretudo quando usado na água para consumo humano promovendo grande abrangência coletiva, e também sua importância no processo de floculação em águas naturais, justificam a necessidade da sua quantificação, somada à tendência atual de técnicas de determinação com baixa geração de resíduos. Neste trabalho, foi desenvolvido um sistema automatizado em fluxo utilizando o conceito de multicomutação para determinação de fluoreto em águas. O sistema proposto permitiu que várias etapas do procedimento analítico fossem realizadas sem a intervenção do operador. O módulo de análise foi desenvolvido levando-se em consideração as características da reação química envolvida na análise de fluoreto em águas pelo método SPADNS. Para a otimização do sistema proposto foram feitos estudos do tempo de abertura das válvulas solenóides, comprimento do reator, vazão, número de ciclos, concentração de SPADNS, concentração de ZrOCl2.8H2O e efeito da concentração de NaAsO2 no sinal analítico que, respectivamente, apresentaram valores considerados ótimos de 0,1 s para a válvula de inserção da mistura indicadora e 0,5 s para a válvula de inserção da amostra, 75 cm, 2,8 mL.min-1, 8 ciclos, 3,36 x 10-3 mol.L-1 e 1,66 x 10-3 mol.L-1, além de não apresentar diferença significativa no sinal analítico quando do uso de NaAsO2 para a eliminação de cloro residual. O sistema proporcionou uma faixa de resposta linear mais ampla (0,4 a 1,6 mg.L-1 de fluoreto) quando foi utilizado sal de zircônio na concentração de 1,66 x 10-3 mol.L-1 para uma equação da curva de calibração y = 0,004 + 0,13675 x, r = 0,999, limites de detecção (LD) e quantificação (LQ) estimados em 0,019 mg.L-1 e 0,066 mg.L-1, respectivamente, ao nível de confiança de 99,7%, para n = 4 e desvio padrão 0,00107, apresentando-se, portanto, repetitivo e preciso, além de apresentar baixo consumo de reagentes (37 μL da mistura indicadora incluídos em 2,3 mL de resíduo total por réplica) e frequência analítica de 68 determinações por hora. Na comparação de métodos, o teste t de Student não apresentou diferença significativa, uma vez que o tcal = 1,840 para amostras de águas de abastecimento e tcal = 1,017 para amostras de águas minerais foram menores que ttab = 2,776 ao nível de confiança de 95%. O teste de recuperação, de modo geral, comprovou a boa adaptação do método proposto.
12

DETERMINAÇÃO ESPECTROFOTOMÉTRICA DE DICLOFENACO DE SÓDIO EM FORMULAÇÃO FARMACÊUTICA EMPREGANDO O CONCEITO DE FIA-MULTICOMUTAÇÃO / SPECTROPHOTOMETRIC DETERMINATION OF SODIUM DICLOFENAC IN PHARMACEUTICAL FORMULATION USING THE CONCEPT OF FIA-MULTICOMMUTATION

Gomes, Paulo Roberto Barros 28 March 2014 (has links)
Made available in DSpace on 2016-08-19T12:56:47Z (GMT). No. of bitstreams: 1 Dissertacao PAULO ROBERTO BARROS GOMES.pdf: 750823 bytes, checksum: 6bcfd2cc25720b82e68f10aa3fb00c5a (MD5) Previous issue date: 2014-03-28 / International and national bodies require the development of analytical methods that are rapid, inexpensive and accurate for the determination of drugs. One way to meet these requirements a method of flow injection analysis employing multicommutation and spectrophotometric detection was used. In this paper an automated system was developed to determine diclofenac sodium in injectables. The reaction is based on the oxidation of diclofenac sodium with potassium permanganate in acid medium be-ing monitored at 465 nm this. The calibration curve was linear over the concentration range of 20-80 mg Lˉ¹ with a detection limit of 0.1 mg Lˉ¹ standard deviation of 0.9% (n = 20) and Sample Rate 80 samples per hour. The proposed method was applied successfully in three injectable solutions and the samples were compared with the official method and other automated methods employing the same reaction. / Os organismos internacionais e nacionais exigem o desenvolvimento de metodologi-as analíticas que sejam rápidas, baixo custo e precisas para a determinação de fár-macos. Uma forma de atender a essas exigências foi utilizado um método de análise por injeção em fluxo empregando multicomutação e com detecção espectrofotomé-trica. Neste trabalho um sistema automático foi desenvolvido para determinar o di-clofenaco de sódio em injetáveis. A reação é baseada na oxidação do diclofenaco de sódio com permanganato de potássio em meio ácido sendo esta monitorada a 465 nm. A curva de calibração foi linear no intervalo de concentração de 20-80 mg Lˉ¹, com um limite de detecção de 0,1 mg Lˉ¹, desvio padrão de 0,9% (n = 20) e taxa de amostragem de 80 determinações por hora. O método proposto foi aplicado com sucesso em três soluções injetáveis e as amostras foram comparadas com a meto-dologia oficial e outros métodos automáticos que empregam a mesma reação.
13

"Desenvolvimento de instrumentação e procedimentos analíticos automáticos para a determinação espectrofotométrica de tensoativos em águas" / "Development of the instrumentation and automatic analytical procedures for spectrophotometric determination of surfactants in waters"

Lavorante, André Fernando 23 February 2006 (has links)
"Neste trabalho, propõe-se o desenvolvimento de instrumentação e procedimentos analíticos automáticos para a determinação de tensoativos em águas empregando o conceito de multicomutação em fluxo. Visando a miniaturização do sistema, a minimização do consumo de reagentes, e da geração de efluentes foram utilizadas mini-bombas solenóide para a propulsão dos fluidos e válvulas solenóide de estrangulamento para controlar a manipulação das soluções. Estes dispositivos foram controlados por um microcomputador equipado com uma interface eletrônica baseada no circuito integrado ULN2803A a qual foi acoplada à saída da impressora. Como sistema de detecção foram empregados um espectrofotômetro HP8452A, um espectrofotômetro multicanal com arranjo linear de fotodetectores do tipo CCD e um fotômetro baseado em dois LEDs (azul e vermelho) como fonte de radiação e um fotodiodo de silício (IPL10530DAL) como detector. A aquisição dos dados do fotômetro foi realizada com um multímetro digital com saída serial RS232, empregando um programa escrito em linguagem VISUAL BASIC 3.0. No mesmo programa foram incluídas rotinas para controle do módulo de análise. Primeiramente, foram desenvolvidos a instrumentação e os procedimentos analíticos para a determinação independente de tensoativos aniônicos e catiônicos em águas. O mesmo módulo de análises foi utilizado para os dois tensoativos e foi constituído de quatro mini-bombas solenóide. O procedimento proposto para a determinação de tensoativos aniônicos foi baseado na substituição do reagente cromogênico alaranjado de metila (MO) pelo tensoativo aniônico dodecilbenzeno sulfonato de sódio (DBS), formando o par-iônico com o tensoativo catiônico cloreto de cetilpiridino (CPC) em pH 5,0. A instrumentação proposta possibilitou a obtenção de resposta linear entre 1,4 x 10-6 mol L-1 e 1,4 x 10-5 mol L-1 (0,5 - 5 mg L-1) (R = 0,997, n = 7), limite de detecção de 9,8 x 10-8 mol L-1 (0,034 mg L-1), e freqüência de amostragem de 60 determinações por hora. O desvio padrão relativo foi estimado em 0,8 % (n = 11) usando uma solução de referência contendo 5,7 x 10-6 mol L-1 (2 mg L-1) de DBS. Os resultados obtidos pelo método proposto processando amostras de efluentes domésticos e industriais foram comparados com os obtidos empregando-se o método de referência, e não foi observada diferença significativa em nível de confiança de 95 %. Para a determinação de tensoativos catiônicos em águas foi desenvolvido um procedimento baseado na formação do complexo ternário entre tensoativo catiônico CPC, Fe (III) e cromazurol S (CAS) em pH 4,5. Com o sistema proposto, utilizando-se uma cela de detecção de 40 mm de comprimento, obteve-se resposta linear entre 0,1 x 10-5 mol L-1 e 3,0 x 10-5 mol L-1 (0,34 - 10,2 mg L-1) (R = 0,999, n = 9), limite de detecção estimado em 1,0 x 10-7 mol L-1 (0,035 mg L-1), desvio padrão relativo de 0,6 % (n = 11) empregando uma solução de referência contendo 1,0 x 10-5 mol L-1 (3,4 mg L-1) de CPC, e freqüência de amostragem de 72 determinações por hora. O procedimento foi aplicado em amostras de águas coletadas no rio Piracicaba. Empregando-se teste de adição e recuperação foi observada recuperação entre 91 % e 106 %. O módulo de análise para a determinação seqüencial de tensoativos aniônicos e catiônicos foi constituído de duas mini-bombas solenóide e seis válvulas solenóide de estrangulamento. Com o sistema proposto, as características analíticas para os tensoativos aniônicos foram: resposta linear entre 0,1 x 10-5 mol L-1 e 3,0 x 10-5 mol L-1 (0,35 - 10,5 mg L-1) (R = 0,9992, n = 7); limite de detecção estimado em 1,6 x 10-7 mol L-1 (0,056 mg L-1); desvio padrão relativo de 0,6 % (n = 11) usando uma solução de referência contendo 1,0 x 10-5 mol L-1 (3,5 mg L-1) de DBS. Para os tensoativos catiônicos obteve-se resposta linear entre 0,1 x 10-5 mol L-1 e 3,0 x 10?5 mol L-1 (0,34 - 10,2 mg L-1) (R = 0,9992, n = 7); limite de detecção estimado em 1,4 x 10-7 mol L-1 (0,05 mg L-1); desvio padrão relativo de 0,5 % (n = 11) usando uma solução de referência contendo 1,0 x 10-5 mol L-1 (3,4 mg L-1) de CPC. O consumo das soluções de reagentes e de amostra foram de 400 mL e 200 mL, respectivamente, e freqüência de amostragem de 60 determinações por hora, para ambos tensoativos. O sistema foi aplicado em amostras de águas coletadas no rio Corumbataí, e os resultados obtidos com testes de adição e recuperação variaram entre 91 % e 105 %. Aplicando-se teste-t entre os resultados obtidos pelo procedimento proposto e pelos métodos de referência (aniônicos) e de validação (catiônicos), os resultados foram concordantes em nível de 95 % de confiança." / "In this work, development of the instrumentation and automatic analytical procedures for spectrophotometric determination of surfactants in waters employing the multicommutation concept were proposed. Aiming to system miniaturization, reduction of reagents consumption and effluents generation, solenoids micro-pump and solenoids pinch valves were used for the fluids propulsion and for solutions management, respectively. These devices were controlled by a microcomputer equipped with an electronic interface based on the integrate circuit ULN2803A that was coupled to the printer output. As system detection was employed an spectrophotometer model HP8452A, a multichannel spectrophotometer with CCD array linear arrangement of photodetectors and a homemade LED based photometer comprising two LEDs (blue and red) as radiation source and a photodiode (IPL10530DAL) as detector. In this case, the data acquisition was accomplished with a digital multimeter with serial out put RS232 employing a software wrote in VISUAL BASIC 3.0. The software comprised also routines to control the analysis module. Firstly, instrumentation and analytical procedures for independent determination of anionic and cationic surfactants in waters were developed. The same flow system comprised of four solenoid micro-pumps and it was employed for both surfactants. The procedure proposed for the determination of anionic surfactant was based on the substitution reaction of orange methyl (MO) by anionic surfactant (sodium dodecylbenzene sulfonate - DBS) to form an ion-pair with the cetyl pyridine (CPC) at pH 5.0. The proposed instrumentation allowed the achievement of a lineal response range between 1.4 x 10-6 mol L-1 and 1.4 x 10-5 mol L-1 (0.5 – 5.0 mg L-1) (R = 0.997, n = 7), a detection limit of 9.8 x 10-8 mol L-1 (0.034 mg L-1), a relative standard deviation of 0.8% (n = 11) for a reference solution containing 5.7 x 10-6 mol L-1 (2.0 mg L-1) DBS and sampling throughput of 60 determinations per hour. Results obtained applying the proposed procedure for domestic and industrial effluent samples were compared with those obtained using reference method and no significant differences at the 95 % confidence level was observed. For the determination of cationic surfactant in waters the procedure was developed based on the ternary complex formation between CPC, Fe (III) and chromazurol S at pH 4.5. The proposed system comprised a flow cell device with 40 mm optical path-length presented the following features: a linear response range between 0.1 x 10-5 mol L-1 e 3.0 x 10-5 mol L-1 (0.34 – 10.2 mg L-1) (R = 0.999, n = 9); a detection limit of 1.0 x 10-7 mol L-1 (0.035 mg L-1); a relative standard deviation of 0.6 % (n = 11) for a reference solution containing 1.0 x 10-5 mol L-1 (3.4 mg L-1) CPC; and a sampling throughput of 72 determinations per hour. The procedure was applied to samples waters collected in the Piracicaba River. Using standard addition test recoveries between 91 % and 106 % were observed. The flow network for the sequential determination of anionic and cationic surfactants comprised two solenoid micro-pumps and six solenoid pinch valves. Employing the system proposed for the determination of anionic surfactants the folowing analytical characteristics: linear response range between 0.1 x 10-5 mol L-1 e 3.0 x 10-5 mol L-1 (0.35 – 10.5 mg L-1) (R = 0.9992, n = 7); a detection limit of 1.6 x 10-7 mol L-1 (0.056 mg L-1); a relative standard deviation of 0.6 % (n = 11) for a reference solution containing 1.0 x 10-5 mol L-1 (3.5 mg L-1) DBS were observed. For cationic surfactants a linear response range between 0.1 x 10-5 mol L-1 e 3.0 x 10?5 mol L-1 (0.34 - 10.2 mg L-1) (R = 0.9992, n = 7), a detection limit of 1.4 x 10-7 mol L-1 (0.05 mg L-1), a relative standard deviation of 0.5 % (n = 11) for a reference solution containing 1.0 x 10-5 mol L-1 (3.4 mg L-1) CPC were observed. In both cases, the reagents and sample consumption were 400 mL and 200 mL, respectively. The sampling throughput of 60 determinations per hour was achieved for both surfactants. The system was applied to waters samples from the Corumbataí River. The results obtained using the standard addition test presented recoveries between 91 % and 105 %. Applying t-test between the results obtained by the proposed procedures and those obtained using reference procedures showed that for anionic and cationic surfactants, the results were concordant at 95% confidence level."
14

"Desenvolvimento de instrumentação e procedimentos analíticos automáticos para a determinação espectrofotométrica de tensoativos em águas" / "Development of the instrumentation and automatic analytical procedures for spectrophotometric determination of surfactants in waters"

André Fernando Lavorante 23 February 2006 (has links)
"Neste trabalho, propõe-se o desenvolvimento de instrumentação e procedimentos analíticos automáticos para a determinação de tensoativos em águas empregando o conceito de multicomutação em fluxo. Visando a miniaturização do sistema, a minimização do consumo de reagentes, e da geração de efluentes foram utilizadas mini-bombas solenóide para a propulsão dos fluidos e válvulas solenóide de estrangulamento para controlar a manipulação das soluções. Estes dispositivos foram controlados por um microcomputador equipado com uma interface eletrônica baseada no circuito integrado ULN2803A a qual foi acoplada à saída da impressora. Como sistema de detecção foram empregados um espectrofotômetro HP8452A, um espectrofotômetro multicanal com arranjo linear de fotodetectores do tipo CCD e um fotômetro baseado em dois LEDs (azul e vermelho) como fonte de radiação e um fotodiodo de silício (IPL10530DAL) como detector. A aquisição dos dados do fotômetro foi realizada com um multímetro digital com saída serial RS232, empregando um programa escrito em linguagem VISUAL BASIC 3.0. No mesmo programa foram incluídas rotinas para controle do módulo de análise. Primeiramente, foram desenvolvidos a instrumentação e os procedimentos analíticos para a determinação independente de tensoativos aniônicos e catiônicos em águas. O mesmo módulo de análises foi utilizado para os dois tensoativos e foi constituído de quatro mini-bombas solenóide. O procedimento proposto para a determinação de tensoativos aniônicos foi baseado na substituição do reagente cromogênico alaranjado de metila (MO) pelo tensoativo aniônico dodecilbenzeno sulfonato de sódio (DBS), formando o par-iônico com o tensoativo catiônico cloreto de cetilpiridino (CPC) em pH 5,0. A instrumentação proposta possibilitou a obtenção de resposta linear entre 1,4 x 10-6 mol L-1 e 1,4 x 10-5 mol L-1 (0,5 - 5 mg L-1) (R = 0,997, n = 7), limite de detecção de 9,8 x 10-8 mol L-1 (0,034 mg L-1), e freqüência de amostragem de 60 determinações por hora. O desvio padrão relativo foi estimado em 0,8 % (n = 11) usando uma solução de referência contendo 5,7 x 10-6 mol L-1 (2 mg L-1) de DBS. Os resultados obtidos pelo método proposto processando amostras de efluentes domésticos e industriais foram comparados com os obtidos empregando-se o método de referência, e não foi observada diferença significativa em nível de confiança de 95 %. Para a determinação de tensoativos catiônicos em águas foi desenvolvido um procedimento baseado na formação do complexo ternário entre tensoativo catiônico CPC, Fe (III) e cromazurol S (CAS) em pH 4,5. Com o sistema proposto, utilizando-se uma cela de detecção de 40 mm de comprimento, obteve-se resposta linear entre 0,1 x 10-5 mol L-1 e 3,0 x 10-5 mol L-1 (0,34 - 10,2 mg L-1) (R = 0,999, n = 9), limite de detecção estimado em 1,0 x 10-7 mol L-1 (0,035 mg L-1), desvio padrão relativo de 0,6 % (n = 11) empregando uma solução de referência contendo 1,0 x 10-5 mol L-1 (3,4 mg L-1) de CPC, e freqüência de amostragem de 72 determinações por hora. O procedimento foi aplicado em amostras de águas coletadas no rio Piracicaba. Empregando-se teste de adição e recuperação foi observada recuperação entre 91 % e 106 %. O módulo de análise para a determinação seqüencial de tensoativos aniônicos e catiônicos foi constituído de duas mini-bombas solenóide e seis válvulas solenóide de estrangulamento. Com o sistema proposto, as características analíticas para os tensoativos aniônicos foram: resposta linear entre 0,1 x 10-5 mol L-1 e 3,0 x 10-5 mol L-1 (0,35 - 10,5 mg L-1) (R = 0,9992, n = 7); limite de detecção estimado em 1,6 x 10-7 mol L-1 (0,056 mg L-1); desvio padrão relativo de 0,6 % (n = 11) usando uma solução de referência contendo 1,0 x 10-5 mol L-1 (3,5 mg L-1) de DBS. Para os tensoativos catiônicos obteve-se resposta linear entre 0,1 x 10-5 mol L-1 e 3,0 x 10?5 mol L-1 (0,34 - 10,2 mg L-1) (R = 0,9992, n = 7); limite de detecção estimado em 1,4 x 10-7 mol L-1 (0,05 mg L-1); desvio padrão relativo de 0,5 % (n = 11) usando uma solução de referência contendo 1,0 x 10-5 mol L-1 (3,4 mg L-1) de CPC. O consumo das soluções de reagentes e de amostra foram de 400 mL e 200 mL, respectivamente, e freqüência de amostragem de 60 determinações por hora, para ambos tensoativos. O sistema foi aplicado em amostras de águas coletadas no rio Corumbataí, e os resultados obtidos com testes de adição e recuperação variaram entre 91 % e 105 %. Aplicando-se teste-t entre os resultados obtidos pelo procedimento proposto e pelos métodos de referência (aniônicos) e de validação (catiônicos), os resultados foram concordantes em nível de 95 % de confiança." / "In this work, development of the instrumentation and automatic analytical procedures for spectrophotometric determination of surfactants in waters employing the multicommutation concept were proposed. Aiming to system miniaturization, reduction of reagents consumption and effluents generation, solenoids micro-pump and solenoids pinch valves were used for the fluids propulsion and for solutions management, respectively. These devices were controlled by a microcomputer equipped with an electronic interface based on the integrate circuit ULN2803A that was coupled to the printer output. As system detection was employed an spectrophotometer model HP8452A, a multichannel spectrophotometer with CCD array linear arrangement of photodetectors and a homemade LED based photometer comprising two LEDs (blue and red) as radiation source and a photodiode (IPL10530DAL) as detector. In this case, the data acquisition was accomplished with a digital multimeter with serial out put RS232 employing a software wrote in VISUAL BASIC 3.0. The software comprised also routines to control the analysis module. Firstly, instrumentation and analytical procedures for independent determination of anionic and cationic surfactants in waters were developed. The same flow system comprised of four solenoid micro-pumps and it was employed for both surfactants. The procedure proposed for the determination of anionic surfactant was based on the substitution reaction of orange methyl (MO) by anionic surfactant (sodium dodecylbenzene sulfonate - DBS) to form an ion-pair with the cetyl pyridine (CPC) at pH 5.0. The proposed instrumentation allowed the achievement of a lineal response range between 1.4 x 10-6 mol L-1 and 1.4 x 10-5 mol L-1 (0.5 – 5.0 mg L-1) (R = 0.997, n = 7), a detection limit of 9.8 x 10-8 mol L-1 (0.034 mg L-1), a relative standard deviation of 0.8% (n = 11) for a reference solution containing 5.7 x 10-6 mol L-1 (2.0 mg L-1) DBS and sampling throughput of 60 determinations per hour. Results obtained applying the proposed procedure for domestic and industrial effluent samples were compared with those obtained using reference method and no significant differences at the 95 % confidence level was observed. For the determination of cationic surfactant in waters the procedure was developed based on the ternary complex formation between CPC, Fe (III) and chromazurol S at pH 4.5. The proposed system comprised a flow cell device with 40 mm optical path-length presented the following features: a linear response range between 0.1 x 10-5 mol L-1 e 3.0 x 10-5 mol L-1 (0.34 – 10.2 mg L-1) (R = 0.999, n = 9); a detection limit of 1.0 x 10-7 mol L-1 (0.035 mg L-1); a relative standard deviation of 0.6 % (n = 11) for a reference solution containing 1.0 x 10-5 mol L-1 (3.4 mg L-1) CPC; and a sampling throughput of 72 determinations per hour. The procedure was applied to samples waters collected in the Piracicaba River. Using standard addition test recoveries between 91 % and 106 % were observed. The flow network for the sequential determination of anionic and cationic surfactants comprised two solenoid micro-pumps and six solenoid pinch valves. Employing the system proposed for the determination of anionic surfactants the folowing analytical characteristics: linear response range between 0.1 x 10-5 mol L-1 e 3.0 x 10-5 mol L-1 (0.35 – 10.5 mg L-1) (R = 0.9992, n = 7); a detection limit of 1.6 x 10-7 mol L-1 (0.056 mg L-1); a relative standard deviation of 0.6 % (n = 11) for a reference solution containing 1.0 x 10-5 mol L-1 (3.5 mg L-1) DBS were observed. For cationic surfactants a linear response range between 0.1 x 10-5 mol L-1 e 3.0 x 10?5 mol L-1 (0.34 - 10.2 mg L-1) (R = 0.9992, n = 7), a detection limit of 1.4 x 10-7 mol L-1 (0.05 mg L-1), a relative standard deviation of 0.5 % (n = 11) for a reference solution containing 1.0 x 10-5 mol L-1 (3.4 mg L-1) CPC were observed. In both cases, the reagents and sample consumption were 400 mL and 200 mL, respectively. The sampling throughput of 60 determinations per hour was achieved for both surfactants. The system was applied to waters samples from the Corumbataí River. The results obtained using the standard addition test presented recoveries between 91 % and 105 %. Applying t-test between the results obtained by the proposed procedures and those obtained using reference procedures showed that for anionic and cationic surfactants, the results were concordant at 95% confidence level."
15

Desenvolvimento de um fotômetro portátil e de procedimentos analíticos automáticos para determinação de ânions e cátions em fontes de captação de águas para uso doméstico e industrial / Development of portable photometer and automatic analytical procedures for anions and cations determination in sources of water captation for domestic and industrial uses

Feres Junior, Mario Almir 18 December 2006 (has links)
Neste trabalho, foi desenvolvido equipamento portátil e procedimentos analíticos automáticos para determinação de cátions e anions em águas usadas para consumo humano e suprimento. Os procedimentos foram baseados no processo de multicomutação em fluxo e detecção fotométrica empregando fotômetro feito no laboratório. Os sistemas de fluxo foram construídos empregando válvulas solenóide, com interface independente de comutação acionadas por computador usando apenas um canal de bombeamento. O sistema proposto foi controlado por um computador rodando um software escrito em QuickBasic 4.5. Os dói fotômetros baseados em LED foram desenvolvidos usando como detectores de radiação foto-transistores e foto-diodos. Nos dois casos a fonte de radiação (LED) e o foto-detector foram acoplados a cela de fluxo obtendo assim, uma unidade compacta. O fotômetro foi projetado para usar um foto-transistor para determinações seqüenciais de nitrato, nitrito, ferro(II), ferro(III) em águas de rios.O fotômetro proposto usa um foto-diodo para determinação de cloreto por turbidimetria, fosfato e amonium por fotometria. A sistema de fluxo foi desenhado associando-se os processos de multicomutação e multisite garantindo redução de reagente e de efluente. O sistema sistema foi empregado para determinação de cloreto, fosfato e amônio em águas de rios. Os dois sistemas propostos apresentaram excelente performance incluindo boa precisão, freqüência analítica e baixo consumo de reagente. Além disso, o sistema baseado em multisite apresentou baixo volume de efluente gerado. As dimensões reduzidas de ambos os fotômetros e do modulo de analise em fluxo, permitiram a portabilidade, o que possibilita sua aplicação em condições de campo. / In this work it was developed a portable apparatus and automatic analytical procedures for the determination of cations and anions in waters used for human consumption and industrial provisioning. The procedures were based on the multicommutation process in flow analysis and detection was performed using a homemade photometer. The flow systems were designed employing a set of solenoid valves, which were assembled to work as independent commutation units, thus under computer control several solutions were handled using a single pumping channel. The proposed system was controlled by computer running a software wrote in QuickBasic 4.5. The two LED based photometers were developed using as light detection a phototransistor and a photodiode. In both cases, the radiation source (LED) and the photodector were coupled to the flow cell in order to obtain compact unit. The photometer designed using a phototransistor was employed for the sequential determination of nitrate, nitrite, iron(II) and iron(III) in river water. The photometer designed using a photodiode was employed in the system used for the determination of chloride by turbidimetry, phosphate and ammonium by photometry. The flow system was designed associating the multisite and multicommutation process intending reduction of the reagent consumption and waste generation. The useful of the system was proved performing the determination of chloride, ammonium and phosphate in river water. The two proposed systems presented very overall performance including precision and accuracy, analytical frequency and low reagent consumption. Furthermore, the system based on multisite approach presented a very low volume of waster generation. The reduced dimensions of both photometer and flow system module allow their portability, thus we can suggest that the proposed systems are reliable for work in field condition.
16

Desenvolvimento de um fotômetro portátil e de procedimentos analíticos automáticos para determinação de ânions e cátions em fontes de captação de águas para uso doméstico e industrial / Development of portable photometer and automatic analytical procedures for anions and cations determination in sources of water captation for domestic and industrial uses

Mario Almir Feres Junior 18 December 2006 (has links)
Neste trabalho, foi desenvolvido equipamento portátil e procedimentos analíticos automáticos para determinação de cátions e anions em águas usadas para consumo humano e suprimento. Os procedimentos foram baseados no processo de multicomutação em fluxo e detecção fotométrica empregando fotômetro feito no laboratório. Os sistemas de fluxo foram construídos empregando válvulas solenóide, com interface independente de comutação acionadas por computador usando apenas um canal de bombeamento. O sistema proposto foi controlado por um computador rodando um software escrito em QuickBasic 4.5. Os dói fotômetros baseados em LED foram desenvolvidos usando como detectores de radiação foto-transistores e foto-diodos. Nos dois casos a fonte de radiação (LED) e o foto-detector foram acoplados a cela de fluxo obtendo assim, uma unidade compacta. O fotômetro foi projetado para usar um foto-transistor para determinações seqüenciais de nitrato, nitrito, ferro(II), ferro(III) em águas de rios.O fotômetro proposto usa um foto-diodo para determinação de cloreto por turbidimetria, fosfato e amonium por fotometria. A sistema de fluxo foi desenhado associando-se os processos de multicomutação e multisite garantindo redução de reagente e de efluente. O sistema sistema foi empregado para determinação de cloreto, fosfato e amônio em águas de rios. Os dois sistemas propostos apresentaram excelente performance incluindo boa precisão, freqüência analítica e baixo consumo de reagente. Além disso, o sistema baseado em multisite apresentou baixo volume de efluente gerado. As dimensões reduzidas de ambos os fotômetros e do modulo de analise em fluxo, permitiram a portabilidade, o que possibilita sua aplicação em condições de campo. / In this work it was developed a portable apparatus and automatic analytical procedures for the determination of cations and anions in waters used for human consumption and industrial provisioning. The procedures were based on the multicommutation process in flow analysis and detection was performed using a homemade photometer. The flow systems were designed employing a set of solenoid valves, which were assembled to work as independent commutation units, thus under computer control several solutions were handled using a single pumping channel. The proposed system was controlled by computer running a software wrote in QuickBasic 4.5. The two LED based photometers were developed using as light detection a phototransistor and a photodiode. In both cases, the radiation source (LED) and the photodector were coupled to the flow cell in order to obtain compact unit. The photometer designed using a phototransistor was employed for the sequential determination of nitrate, nitrite, iron(II) and iron(III) in river water. The photometer designed using a photodiode was employed in the system used for the determination of chloride by turbidimetry, phosphate and ammonium by photometry. The flow system was designed associating the multisite and multicommutation process intending reduction of the reagent consumption and waste generation. The useful of the system was proved performing the determination of chloride, ammonium and phosphate in river water. The two proposed systems presented very overall performance including precision and accuracy, analytical frequency and low reagent consumption. Furthermore, the system based on multisite approach presented a very low volume of waster generation. The reduced dimensions of both photometer and flow system module allow their portability, thus we can suggest that the proposed systems are reliable for work in field condition.
17

SISTEMA DE MULTICOMUTAÇÃO EM FLUXO PARA A DETERMINAÇÃO ESPECTROFOTOMÉTRICA DE ÁCIDO ACETILSALICILICO EM FÁRMACOS / FLOW MULTICOMMUTATION SYSTEM FOR SPECTROPHOTOMETRIC DETERMINATION OF ACETYLSALICYLIC ACID IN DRUGS

Lima, Helson Souza de 30 May 2014 (has links)
Made available in DSpace on 2016-08-19T12:56:46Z (GMT). No. of bitstreams: 1 DISSERTACAO HELSON SOUZA DE LIMA.pdf: 1216479 bytes, checksum: 18681c87874a4df580759a866dffab2c (MD5) Previous issue date: 2014-05-30 / In this work was developed an analytical procedure employing multicommutation for the determination of acetylsalicylic acid in tablet. The procedure is based on the Trinder reation, wherein the salicylic acid from the hydrolysis of acetylsalicylic acid is reacted of iron (III), forming a purple complex, monitored spectrophotometrically at 525nm. The multicommutation developed system employed three solenoid valves for solution management and a peristaltic pump for the fluid propulsion, and spectrophotometric detection working in the visible range. The optimization of the proposed system have been made to study the carrier solution, flow rate, reactor, numbers of cycle, Trinder reagent concentration, studies of opening time of solenoid valves that opitmal values respectively. HNO₃ as carrier solution , 3.5 ml . minˉ¹ , 80cm , 12 cycles , 10 g.Lˉ¹, 0.1 s for the valve insert reagent and 0.5 s for the insertion of the sample valve.The system provided linear response: range between 25-100 mg.Lˉ¹ of AAS ( R = 0.999 ), with RSD 0.91% ( n = 4 ), good sampling frequency of 72 determination per hour. detection limit (LD) of 0.57 mg.Lˉ¹ and quantification limit (LQ) of 1.89 mg.Lˉ¹. The results obtained with recovery test ranged between 97 and 99%. In a comparison of methods, the test t of Student has not presented relevant difference, once the tcal. = 0,91 were smaller than ttab. = 2.78 at a 95% confidence level. / Neste trabalho foi desenvolvido um procedimento analítico empregando o processo de multicomutação para determinação de ácido acetilsalicílico em comprimidos. O procedimento se baseia na reação de Trinder, onde o ácido salicílico, proveniente da hidrolise alcalina do ácido acetilsalicílico, reage com íons Fe³⁺, formando um complexo de cor púrpura, monitorado espectrofotometricamente em 525nm. O sistema de multicomutação desenvolvido empregou 3 válvulas solenóides de três vias para controlar a manipulação das soluções, uma bomba peristáltica para a propulsão dos fluidos, e um detector espectrofotométrico que opera na região do visível. Na otimização do sistema proposto fizeram-se o estudo da solução transportadora, vazão, reator, número de ciclos, concentração do reagente Trinder, tempo de acionamento das válvulas solenóides que apresentaram os respectivos valores ótimos: HNO3 como solução transportadora, 3,5 mL.minˉ¹, 80cm, 12 ciclos, 10 g.Lˉ¹, 0,1 s para a válvula de inserção reagente e 0,5 s para a válvula de inserção da amostra. O sistema apresentou uma faixa de reposta linear entre 25-100 mg.Lˉ¹ de AAS (R= 0,999), com RSD de 0,91% (n =4), frequência de amostragem de 72 determinações por hora com um limite de detecção de 0,57 mg Lˉ¹ e limite de quantificação de 1,89 mg Lˉ¹. Os resultados obtidos com teste de recuperação variaram entre 97 e 99%. Na comparação de métodos, o teste t de Student não apresentou diferença significativa, uma vez que o tcal = 0,91 foi menor que o ttal =2,78 ao nível de confiança de 95%.
18

Desenvolvimento de um equipamento portátil e de sistema de análises em fluxo empregando multicomutação. Determinação fotométrica de ferro em águas de rios / Development of a portable equipment and a flow analysis system employing multicommutation. Photometric determination of iron in river waters

Miranda, Jeová Correia 20 July 2011 (has links)
O ferro é o elemento mais abundante na Terra e tem importante papel em ciclos biogeoquímicos Neste trabalho foi desenvolvido um procedimento analítico automático para a determinação fotométrica de ferro em águas de rios, empregando um fotômetro baseado em LED e mini-bombas solenoide para o gerenciamento de soluções. O procedimento proposto foi baseado na reação do ferro (III) com o tiocianato de potássio formando um complexo avermelhado com máximo de absorção em 470 nm. Para a determinação de ferro total foi incluída uma etapa de oxidação em linha, usando uma solução de persulfato (S2O82-) como oxidante. O módulo de análises foi constituído por quatro mini-bombas solenoide e uma válvula solenoide de três vias. Para a obtenção de sinais foi construído um fotômetro composto por uma cela de fluxo com caminho óptico de 50 mm, um LED azul (\'lâmbda\'=470 nm) e um fotodetector. Visando utilizar este equipamento portátil para medidas em campo, foram empregadas duas baterias de 6 V para alimentar os dispositivos ativos. Os ensaios em laboratório mostraram que as baterias permitem uma autonomia de mais de 50 horas de trabalho sem recarregá-las. O procedimento desenvolvido apresentou as seguintes características analíticas: resposta linear entre as concentrações de 0,25 e 4,0 mg L-1, segundo a equação Y = (0,0183 ± 0,003) + (0,15326 ± 0,002)X (r=0,9997); limite de detecção 0,013 mg L-1 Fe (III) estimado com 99,7 % de confiança; desvio padrão relativo estimado em 0,95 % (n=15) obtido com uma solução de concentração de 1,5 mg L-1 Fe (III); frequência de amostragem de 50 determinações por hora. Os resultados obtidos pelo procedimento proposto e pelo de referência não apresentaram diferenças significativas com nível de confiança de 95 % / Iron is the most abundant element on Earth and plays an important role in biogeochemical cycles. In this work, an automatic analytical procedure was developed for the photometric determination of iron in river waters, employing a LED-based photometer and solenoid mini-pumps for solution handling. The proposed procedure was based on the reaction between iron (III) and potassium thiocyanate, yielding a red complex with maximum absorption at 470 nm. For the determination of total iron, an in line oxidation step was included, employing a persulfate solution (S2O82-) as oxidant. The module was constructed with four solenoid mini-pumps and a three-way solenoid valve. For data acquisition a photometer was constructed with a 50 mm optical path flow cell, a blue LED (\'lâmbda\'= 470 nm) and a photodetector. Envisioning the use of this portable equipment in field, two 6-Volt batteries were employed to supply energy to the active devices. Laboratory tests showed that the batteries provide more than 50 hours of operation without recharging. The proposed procedure showed the following analytical features: linear response between 0.25 and 4.0 mg L-1, according to the equation Y = (0.0183 ± 0.003) + (0.15326 ± 0.002) X (r = 0.9997); detection limit of 0.013 mg L-1 Fe (III), estimated with 99.7 % of confidence; relative standard deviation estimated as 0.95% (n = 15), obtained with a 1.5 mg L-1 Fe (III) solution; sampling rate of 50 determinations per hour.The results obtained with the proposed and reference procedure did not show significative differences at a 95% confidence level
19

Desenvolvimento de instrumentação e procedimentos analíticos automáticos empregando fotometria em fase sólida para determinação de zinco em produtos farmacêuticos e água / Combining multicommuted flow injection analysis and solid phase photometry for the determination of zinc in pharmaceutical preparation and water

Dias, Tuanne dos Reis 25 August 2010 (has links)
Neste trabalho, é proposto o desenvolvimento de instrumentação e procedimentos analíticos automáticos empregando fotometria em fase sólida para determinação de zinco em produtos farmacêuticos e água. Para implementação do procedimento analítico, todo o sistema foi acoplado a um computador através de uma interface eletrônica. Um software escrito em linguagem QuickBASIC 4.5 permite que o computador efetue o controle da adição das soluções da amostra e do eluente e faça aquisição de dados. O sistema de detecção é constituído de uma cela de fluxo contendo, um LED e um fotodiodo. A geometria da cela de fluxo possibilitava variar o comprimento do caminho óptico. O procedimento para determinação do zinco foi baseado na retenção do analito na fase sólida (TAN-C18), previamente inserida na cela de fluxo, seguido de uma etapa de eluição. Com os parâmetros analíticos otimizados obteve-se resposta linear na faixa de 0,05 a 0,85 mg L-1 (R=0,995), limite detecção de 9,3 \'mü\'g L-1, coeficiente de variação de 1,4% (n=10) e frequência de amostragem de 36 det h-1. O módulo de análise foi aplicado em amostras de produtos farmacêuticos e a exatidão dos resultados foi averiguada comparando com os resultados obtidos por espectrometria de emissão óptica com plasma acoplado indutivamente ICP-OES. Aplicando-se tratamento estatístico apropriado, observou-se que não havia diferença significativa ao nível de confiança de 95 %. Estes resultados comprovam a viabilidade do emprego de fotômetro de LED em fotometria em fase sólida / In this work, it is propose the instrumentation and automatic analytic procedures development using solid phase spectrophotometry for determination of zinc in pharmaceutical preparations and water. For analytic procedure implementation, the whole system was coupled to a computer through an electronic interface. A written software in language QuickBASIC 4.5 allows the computer makes the sample solutions addition control and of eluent and do data acquisition. The detection system is constituted of a flow cell contend, a LED and a photodiode. The flow cell geometry enabled vary the length of the optical path. The procedure for zinc determination was going based in analyte retention in the solid phase (TAN-C18), previously inserted in the flow cell, followed by an elution stage. With the optimized analytic parameters it btained lineal answer in the band of 0,05 to 0,85 mg L-1 (R=0,995), limit detection of 9,3 \'mü\'g L-1, variation coefficient of 1,4% (n=10) and sampling throughput of 36 det h-1. The analysis module was going applied in pharmaceutical preparations samples and the exactness of the results was going ascertained comparing with the results obtained for inductively coupled plasma optic emission spectrometry of with ICP- its. Applying appropriated statistical treatment, it observed that there wasn\'t significant difference to the reliable level of 95 %. These results prove photometer job viability of LED in photometry in solid phase
20

Desenvolvimento de instrumentação e procedimentos automáticos para determinação de arsênio e fluoreto em águas empregando multicomutação em fluxo e detecção fotométrica / Development of instrumentation and automatic procedures for the determination of arsenic and fluoride in waters by using flow multicommutaion and photometric detection

Teixeira, Marcelo Alves 12 May 2010 (has links)
Neste trabalho, é proposto o desenvolvimento de instrumentação e procedimentos analíticos automáticos para a determinação de fluoreto e arsênio em águas empregando o conceito de multicomutação em fluxo e detecção fotométrica. Na determinação de fluoreto, o controle dos dispositivos foi realizado empregando um computador, programado em QuickBasic 4.5. O fotômetro desenvolvido utilizava um fotodetector (OPT301), uma cela de fluxo com 60 mm de caminho óptico e um LED (\'lambda\' = 525 nm), usado como fonte de radiação. Os sinais gerados pelo fotômetro foram convertidos para digital empregando um multímetro digital, que os transferia para o computador através da interface serial RS-232. O procedimento para a determinação de fluoreto foi baseado no método de zircônio/ vermelho de alizarina S, onde o fluoreto retira o zircônio da estrutura metal ligante formando um complexo incolor. Após a seleção das variáveis de controle, o procedimento proposto apresentou resposta linear na faixa de 0,25 a 1,75 mg L-1 (LD = 0,06 mg L-1), desvio relativo menor que 3,5%, freqüência de amostragem de 45 h-1. No sistema para determinação de arsênio em águas, o controle do módulo de análise foi realizado utilizando um microcontrolador da série PIC 18F2553, o qual contém um conversor A/D interno de 12 bits de resolução e capacidade de operar com taxa de amostragem de até 100.000 s-1. O mesmo recebia os parâmetros de controle por um computador via USB 2.0, que utilizava a mesma interface para transferir os dados provenientes do fotômetro. O software para essa comunicação foi escrito em Delphi 7.0 e a linguagem C foi utilizada para a programação do microcontrolador. Como sistema de detecção foi o mesmo empregado na determinação de fluoreto, utilizando um LED (\'lambda\' = 625 nm) como fonte de radiação. O procedimento proposto para a determinação de arsênio foi baseado na reação do arsênio inorgânico com boro-hidreto, onde a arsina formada reagia com azul de metileno em meio micelar. A descoloração da solução de azul de metileno era proporcional à concentração de arsênio presente na amostra. A procedimento proposto apresentou resposta linear na faixa de 2,5 a 40 \'mü\'g L-1 (r = -0,995), limite de detecção de 0,3 \'mü\'g L-1, desvio relativo menor que 6,5 %, freqüência de amostragem de 25 h-1. / The development of instrumentation and automatic procedures for the determination of arsenic and fluoride in waters by using flow multicommutation and photometric detection were proposed. For fluoride determination, the system was controlled by a microcomputer equipped with MS-Dos environment and running a software written in Quick Basic 4.5. It was used a homemade photometric detector OPT301, a 60 mm pathway flow cell, and a light emitting diode (\'lambda\' = 525 nm) as light source. Data acquisition was performed by using a digital multimeter and a microcomputer with RS- 232 serial interface. The method was based on a complexation reaction between fluoride and alizarin red S, where the fluoride takes out the zircon from the metal-binding moieties resulting in color bleaching. After optimization of parameters, the procedure provided linear response in the 0.25 to 1.75 mg L-1 range, limit of detection of 0.06 mg L- 1, coefficient of variation lower than 3.5 %, and sample throughput of 45 determinations per hour. For arsenic determination, the control module was performed by using a PIC 18F2553 microcontroller equipped with a 12 bits resolving power A/D internal converter, working at 100,000 sampling per second rate. Data acquisition was performed by a microcomputer equipped with Windows environment and running a software written in Delphi 7.0. A LED (\'lambda\' = 625 nm), as radiation source, was used for As determinations by using the same detection system used for fluoride determination. The method for As determination was based on the color bleaching of methylene blue in micellar media by AsH3 produced from inorganic As and NaBH4. The color bleaching of methylene blue was proportional to As concentration in the sample. The proposed method provided linear response in the 2.5 to 40 \'mü\'g L-1 range, limit of detection of 0,3 \'mü\'g L-1, coefficient of variation lower than 6.5 %, and sample throughput of 25 determinations per hour.

Page generated in 0.0983 seconds