• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 32
  • 1
  • Tagged with
  • 33
  • 33
  • 28
  • 27
  • 27
  • 26
  • 17
  • 15
  • 11
  • 11
  • 11
  • 9
  • 9
  • 8
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Sistema de análises em fluxo empregando multicomutação para avaliação de toxicidade aguda com Vibrio fischeri / A multicommuted flow-based system for acute toxicity evaluation with Vibrio fischeri

Adame, Andressa 25 April 2014 (has links)
Um sistema de análises em fluxo com multicomutação foi desenvolvido para a mecanização do bioensaio de toxicidade aguda com a bactéria Vibrio fischeri, o qual é baseado na diminuição da luminescência bacteriana causada por espécies tóxicas.Microbombas solenoide foram utilizadas para melhorar as condições de mistura, permitindo também que diluições fossem realizadas em linha com a alteração do volume de amostra e a sobreposição parcial entre a zona da amostra e a suspensão bacteriana. Uma cela de fluxo em espiral, posicionada na janela de emissão de um espectrofluorímetro, foi empregada para as medidas de luminescência e um banho de água construído em laboratório, baseado no efeito Peltier, foi utilizado para manter a temperatura do bioensaio em (13,0±0,1) °C. Um pequeno volume da suspensão bacteriana (120 ?L) foi selecionado visando minimizar o consumo e, consequentemente, os custos do ensaio. O tempo de contato entre a suspensão bacteriana e a amostra foi reduzido para 5 min para aumentar a frequência de amostragem e evitar a atenuação da luminescência devido ao tempo de vida curto das bactérias. Os valores de CE50 para os controles positivos foram estimados em 2,5 ± 0,7, 2,0 ± 0,5 e 10 ± 4 mg L-1 para o Zn(II), Cu(II), e Cr(VI), respectivamente, sendo concordantes com os valores da literatura. Os valores de CE50 para alguns poluentes emergentes (parabenos, cafeína, acetaminofeno, diclofenaco e ácido salicílico) concordaram com os obtidos utilizando o kit comercial BioTox(TM), realizado em micro placa, a nível de confiança de 95 %. Os coeficientes de variação foram estimados em 2,4 e 2 % (n = 10), na ausência e na presença de 0,6 mg L-1 de Zn(II), respectivamente. O sistema de análises em fluxo proposto é, então, uma alternativa simples, rápida, robusta e precisa para a determinação da toxicidade aguda utilizando pequenos volumes de amostra e suspensão bacteriana. Além disso, o sistema apresenta vantagens em comparação com os bioensaios em batelada e em fluxo, tais como ajuste de salinidade e diluições das amostras em linha e a determinação da cinética de toxicidade das espécies químicas / A multicommuted flow system was developed for automation of the acute toxicity bioassay using Vibrio fischeri bacteria, which exploits the decrease of the bacterial luminescence caused by toxic species. Solenoid micro-pumps were employed to improve mixing conditions and to perform on-line dilutions of the tested compounds by changing the sample volume and exploiting the partial overlap between sample zone and the bacterial suspension. A spiral flow cell, placed at the emission window of a spectrofluorimeter, was employed for signal measurement and a lab-made water bath based on the Peltier effect was used for maintain the temperature of the bioassay at (13.0±0.1) oC. A low volume of the bacterial suspension (120 ?L) was selected in order to minimize its consumption and, consequently, the costs of the assay. The contact time between bacterial suspension and sample was reduced to 5 min to increase the sampling rate and to avoid luminescence fading due to the bacteria short lifetime. EC50 values for positive controls were estimated as 2.5 ± 0.7, 2.0 ± 0.5 and 10 ± 4 for Zn(II), Cu(II), and Cr(VI), respectively, being in agreement with literature values. The EC50 values for some emerging pollutants (parabens, caffeine, acetaminophen, diclofenac and salicylic acid) agreed with those obtained from commercial BioTox(TM) kit performed in micro plate at the 95% confidence level. The coefficients of variation were estimated as 2.4 and 2 % (n=10), in the absence and presence of 0.6 mg L-1 Zn(II), respectively. The proposed flow system is then a simple, fast, robust and accurate alternative for acute toxicity determination, using low sample and bacterial suspension volumes. Furthermore, the system presents advantages in comparison to batch and previous flow-based bioassays, such as the achievement of in-line salinity adjustment and sample dilutions, and the determination of toxicity kinetic for every assayed chemical species
22

Sistema de análises em fluxo empregando multicomutação para avaliação de toxicidade aguda com Vibrio fischeri / A multicommuted flow-based system for acute toxicity evaluation with Vibrio fischeri

Andressa Adame 25 April 2014 (has links)
Um sistema de análises em fluxo com multicomutação foi desenvolvido para a mecanização do bioensaio de toxicidade aguda com a bactéria Vibrio fischeri, o qual é baseado na diminuição da luminescência bacteriana causada por espécies tóxicas.Microbombas solenoide foram utilizadas para melhorar as condições de mistura, permitindo também que diluições fossem realizadas em linha com a alteração do volume de amostra e a sobreposição parcial entre a zona da amostra e a suspensão bacteriana. Uma cela de fluxo em espiral, posicionada na janela de emissão de um espectrofluorímetro, foi empregada para as medidas de luminescência e um banho de água construído em laboratório, baseado no efeito Peltier, foi utilizado para manter a temperatura do bioensaio em (13,0±0,1) °C. Um pequeno volume da suspensão bacteriana (120 ?L) foi selecionado visando minimizar o consumo e, consequentemente, os custos do ensaio. O tempo de contato entre a suspensão bacteriana e a amostra foi reduzido para 5 min para aumentar a frequência de amostragem e evitar a atenuação da luminescência devido ao tempo de vida curto das bactérias. Os valores de CE50 para os controles positivos foram estimados em 2,5 ± 0,7, 2,0 ± 0,5 e 10 ± 4 mg L-1 para o Zn(II), Cu(II), e Cr(VI), respectivamente, sendo concordantes com os valores da literatura. Os valores de CE50 para alguns poluentes emergentes (parabenos, cafeína, acetaminofeno, diclofenaco e ácido salicílico) concordaram com os obtidos utilizando o kit comercial BioTox(TM), realizado em micro placa, a nível de confiança de 95 %. Os coeficientes de variação foram estimados em 2,4 e 2 % (n = 10), na ausência e na presença de 0,6 mg L-1 de Zn(II), respectivamente. O sistema de análises em fluxo proposto é, então, uma alternativa simples, rápida, robusta e precisa para a determinação da toxicidade aguda utilizando pequenos volumes de amostra e suspensão bacteriana. Além disso, o sistema apresenta vantagens em comparação com os bioensaios em batelada e em fluxo, tais como ajuste de salinidade e diluições das amostras em linha e a determinação da cinética de toxicidade das espécies químicas / A multicommuted flow system was developed for automation of the acute toxicity bioassay using Vibrio fischeri bacteria, which exploits the decrease of the bacterial luminescence caused by toxic species. Solenoid micro-pumps were employed to improve mixing conditions and to perform on-line dilutions of the tested compounds by changing the sample volume and exploiting the partial overlap between sample zone and the bacterial suspension. A spiral flow cell, placed at the emission window of a spectrofluorimeter, was employed for signal measurement and a lab-made water bath based on the Peltier effect was used for maintain the temperature of the bioassay at (13.0±0.1) oC. A low volume of the bacterial suspension (120 ?L) was selected in order to minimize its consumption and, consequently, the costs of the assay. The contact time between bacterial suspension and sample was reduced to 5 min to increase the sampling rate and to avoid luminescence fading due to the bacteria short lifetime. EC50 values for positive controls were estimated as 2.5 ± 0.7, 2.0 ± 0.5 and 10 ± 4 for Zn(II), Cu(II), and Cr(VI), respectively, being in agreement with literature values. The EC50 values for some emerging pollutants (parabens, caffeine, acetaminophen, diclofenac and salicylic acid) agreed with those obtained from commercial BioTox(TM) kit performed in micro plate at the 95% confidence level. The coefficients of variation were estimated as 2.4 and 2 % (n=10), in the absence and presence of 0.6 mg L-1 Zn(II), respectively. The proposed flow system is then a simple, fast, robust and accurate alternative for acute toxicity determination, using low sample and bacterial suspension volumes. Furthermore, the system presents advantages in comparison to batch and previous flow-based bioassays, such as the achievement of in-line salinity adjustment and sample dilutions, and the determination of toxicity kinetic for every assayed chemical species
23

Desenvolvimento de instrumentação e procedimentos automáticos para determinação de arsênio e fluoreto em águas empregando multicomutação em fluxo e detecção fotométrica / Development of instrumentation and automatic procedures for the determination of arsenic and fluoride in waters by using flow multicommutaion and photometric detection

Marcelo Alves Teixeira 12 May 2010 (has links)
Neste trabalho, é proposto o desenvolvimento de instrumentação e procedimentos analíticos automáticos para a determinação de fluoreto e arsênio em águas empregando o conceito de multicomutação em fluxo e detecção fotométrica. Na determinação de fluoreto, o controle dos dispositivos foi realizado empregando um computador, programado em QuickBasic 4.5. O fotômetro desenvolvido utilizava um fotodetector (OPT301), uma cela de fluxo com 60 mm de caminho óptico e um LED (\'lambda\' = 525 nm), usado como fonte de radiação. Os sinais gerados pelo fotômetro foram convertidos para digital empregando um multímetro digital, que os transferia para o computador através da interface serial RS-232. O procedimento para a determinação de fluoreto foi baseado no método de zircônio/ vermelho de alizarina S, onde o fluoreto retira o zircônio da estrutura metal ligante formando um complexo incolor. Após a seleção das variáveis de controle, o procedimento proposto apresentou resposta linear na faixa de 0,25 a 1,75 mg L-1 (LD = 0,06 mg L-1), desvio relativo menor que 3,5%, freqüência de amostragem de 45 h-1. No sistema para determinação de arsênio em águas, o controle do módulo de análise foi realizado utilizando um microcontrolador da série PIC 18F2553, o qual contém um conversor A/D interno de 12 bits de resolução e capacidade de operar com taxa de amostragem de até 100.000 s-1. O mesmo recebia os parâmetros de controle por um computador via USB 2.0, que utilizava a mesma interface para transferir os dados provenientes do fotômetro. O software para essa comunicação foi escrito em Delphi 7.0 e a linguagem C foi utilizada para a programação do microcontrolador. Como sistema de detecção foi o mesmo empregado na determinação de fluoreto, utilizando um LED (\'lambda\' = 625 nm) como fonte de radiação. O procedimento proposto para a determinação de arsênio foi baseado na reação do arsênio inorgânico com boro-hidreto, onde a arsina formada reagia com azul de metileno em meio micelar. A descoloração da solução de azul de metileno era proporcional à concentração de arsênio presente na amostra. A procedimento proposto apresentou resposta linear na faixa de 2,5 a 40 \'mü\'g L-1 (r = -0,995), limite de detecção de 0,3 \'mü\'g L-1, desvio relativo menor que 6,5 %, freqüência de amostragem de 25 h-1. / The development of instrumentation and automatic procedures for the determination of arsenic and fluoride in waters by using flow multicommutation and photometric detection were proposed. For fluoride determination, the system was controlled by a microcomputer equipped with MS-Dos environment and running a software written in Quick Basic 4.5. It was used a homemade photometric detector OPT301, a 60 mm pathway flow cell, and a light emitting diode (\'lambda\' = 525 nm) as light source. Data acquisition was performed by using a digital multimeter and a microcomputer with RS- 232 serial interface. The method was based on a complexation reaction between fluoride and alizarin red S, where the fluoride takes out the zircon from the metal-binding moieties resulting in color bleaching. After optimization of parameters, the procedure provided linear response in the 0.25 to 1.75 mg L-1 range, limit of detection of 0.06 mg L- 1, coefficient of variation lower than 3.5 %, and sample throughput of 45 determinations per hour. For arsenic determination, the control module was performed by using a PIC 18F2553 microcontroller equipped with a 12 bits resolving power A/D internal converter, working at 100,000 sampling per second rate. Data acquisition was performed by a microcomputer equipped with Windows environment and running a software written in Delphi 7.0. A LED (\'lambda\' = 625 nm), as radiation source, was used for As determinations by using the same detection system used for fluoride determination. The method for As determination was based on the color bleaching of methylene blue in micellar media by AsH3 produced from inorganic As and NaBH4. The color bleaching of methylene blue was proportional to As concentration in the sample. The proposed method provided linear response in the 2.5 to 40 \'mü\'g L-1 range, limit of detection of 0,3 \'mü\'g L-1, coefficient of variation lower than 6.5 %, and sample throughput of 25 determinations per hour.
24

Desenvolvimento de sistemas de análises em fluxo por multicomutação para determinação de poluentes ambientais / Development of systems of flow injection analysis with commutation for determination of environmental pollutants

Carlos Martín Infante Córdova 23 September 2008 (has links)
O presente trabalho teve como objetivo o desenvolvimento de procedimentos analíticos baseados na análise em fluxo com multicomutação, acoplada à detecção por fluorescência, espectrofotometria com longo caminho óptico ou quimiluminescência em guias de ondas (LCW), para a determinação de poluentes ambientais. Os procedimentos desenvolvidos atendem aos requisitos de sensibilidade e limite de detecção impostos pela legislação ambiental vigente e as características analíticas encontram-se em concordância com as tendências atuais de redução do consumo de amostras e reagentes, da geração de resíduos e de custo, apresentando alta freqüência de amostragem e operação simples. Os módulos de análises desenvolvidos são compactos, podendo ser adaptados para o monitoramento in situ. Com o acoplamento da cela LCW de 100 cm de caminho óptico a sistemas de análises por injeção em fluxo e monossegmentado, para medidas por turbidimetria e espectrofotometria, foi observada significativa melhora nos limites de detecção e sensibilidade. Discrepâncias entre o aumento de sensibilidade verificado e previsto pela lei de Beer têm relação com diferenças de dispersão em celas de 1 e 100 cm. Para a determinação espectrofotométrica de paraquat, foi desenvolvido um módulo de análises com micro-bombas solenóides. Ácido dehidroascórbico foi empregado como reagente, sendo a solução estável por uma semana. Resposta linear foi observada de 0,1 a 5,0 mg L1, r=0,997, com limite de detecção, coeficiente de variação e freqüência de amostragem estimados em 22 µg L-1, 1,0% (n=10) e 63 h-1, respectivamente. Os resultados para amostras de águas foram concordantes com o procedimento de referência (95% de confiança). Para a determinação fluorimétrica de cianeto dissociável em ácidos, foi desenvolvido um módulo de análises com válvulas solenóides, explorando a reação com oftalaldeído e glicina. Sensibilidade 2 vezes maior foi observada com a retenção da zona de amostra por 60 s, com resposta linear entre 1 e 200 µg L-1, r=0,999. O coeficiente de variação, limite de detecção e freqüência de amostragem foram estimados em 1,4% (n=10), 0,5 µg L-1 e 22 h-1, respectivamente. Com prévia etapa de separação por difusão gasosa, o procedimento foi aplicado em amostras de águas naturais, sendo os resultados concordantes com o procedimento de referência ao nível de confiança de 95%. Para a especiação redox de cromo, os procedimentos analíticos foram baseados em sistemas de análises em fluxo com micro-bombas solenóides. O Cr(VI) foi determinado por espectrofotometria de longo caminho óptico com difenilcarbazida. Resposta linear foi observada entre 2 e 40 g L-1, r=0,973. O limite de detecção, coeficiente de variação e freqüência de amostragem foram estimados em 1,8 µg L-1, 0,6% (n=10) e 55 h-1, respectivamente. Quimiluminescência foi utilizada para determinar Cr(III), com resposta linear observada entre 2 e 50 µg L-1, com r=0,999. O limite de detecção, coeficiente de iv variação e freqüência de amostragem foram estimados em 0,38 µg L-1, 3,3% (n=10) e 50 h-1, respectivamente. Oxidação em linha foi também implementada para a determinação espectrofotométrica de cromo total. Em amostras de águas naturais, os resultados foram concordantes para Cr(VI), mas efeitos de matriz foram observados para Cr(III), aparentemente devido à complexação com sustâncias húmicas. / This work aimed the development of analytical procedures based on flow analysis with multicommutation, coupled to detection by fluorescence, long pathlength spectrophotometry or chemiluminescence in liquid-core waveguides (LCW), for determination of environmental pollutants. The developed procedures are in accordance with the requirements of sensitivity and detection limits of the current environmental legislation and the analytical characteristics are in agreement with current trends as low sample and reagents consumption, low waste generation, high sampling rate, low cost and simple operation. The compact flow systems could be adapted for in situ monitoring. Improvements in detection limit and sensitivity were observed by coupling the 100-cm LCW to flow injection analysis and monosegmented flow analysis for turbidimetric and spectrophotometric measurements. Discrepancies between the experimentally evaluated increase in sensitivity and that estimated by the Beers law are related to differences in sample dispersion with 1 and 100 cm flow cells. A multicommuted flow-system with solenoid micro-pumps was used for the spectrophotometric determination of paraquat. The reducing reagent, dehydroascorbic acid, was stable for at least one week. Linear response was observed from 0.1 to 5.0 mg L-1, with r=0.997 and detection limit, coefficient of variation and sampling rate estimated as 22 µg L-1, 1.0% (n=10) and 63 h-1, respectively. The procedure was applied for paraquat determination in water samples, yielding results in agreement with the reference procedure at the 95% confidence level. For the fluorimetric determination of Weak Acid Dissociable Cyanide, a multicommuted flow system was development with solenoid valves, exploiting the reaction with o-phthalaldehyde and glycine. A two-fold higher sensitivity was observed with a 60-s stopped-flow interval, with linear response between 1 and 200 µg L-1, r=0.999. The coefficient of variation, detection limit and sampling rate were estimated as 1.4% (n=10), 0.5 µg L-1 and 22 h-1, respectively. After separation by gas diffusion, the procedure was applied to the analysis of natural water samples, with results in agreement with the reference procedure at the 95% confidence level. For redox chromium speciation, the procedures were based on a multicommuted flow system with solenoid micro-pumps. The determination of Cr(VI) was performed by long pathlength spectrophotometrywith diphenylcarbazide. Linear response was observed between 2 and 40 g L-1, r=0.973. The detection limit, coefficient of variation and sampling rate were estimated as 1.7 g L-1, 0.6% (n=10) and 55 h-1, respectively. Chemiluminescence was used to determine Cr(III), being the linear response observed between 2 and 50 µg L-1, with r=0.999. The detection limit, coefficient of variation and sampling rate were estimated as 0.38 µg L-1, 3.3% (n=10) and 50 h-1, respectively. On-line oxidation was also implemented for the determination of total chromium. In natural water samples, results were consistent for Cr(VI), but matrix vi effects were observed in Cr(III) determination, apparently in view of complexation with humic substances.
25

Desenvolvimento de sistemas de análises em fluxo por multicomutação para determinação de poluentes ambientais / Development of systems of flow injection analysis with commutation for determination of environmental pollutants

Córdova, Carlos Martín Infante 23 September 2008 (has links)
O presente trabalho teve como objetivo o desenvolvimento de procedimentos analíticos baseados na análise em fluxo com multicomutação, acoplada à detecção por fluorescência, espectrofotometria com longo caminho óptico ou quimiluminescência em guias de ondas (LCW), para a determinação de poluentes ambientais. Os procedimentos desenvolvidos atendem aos requisitos de sensibilidade e limite de detecção impostos pela legislação ambiental vigente e as características analíticas encontram-se em concordância com as tendências atuais de redução do consumo de amostras e reagentes, da geração de resíduos e de custo, apresentando alta freqüência de amostragem e operação simples. Os módulos de análises desenvolvidos são compactos, podendo ser adaptados para o monitoramento in situ. Com o acoplamento da cela LCW de 100 cm de caminho óptico a sistemas de análises por injeção em fluxo e monossegmentado, para medidas por turbidimetria e espectrofotometria, foi observada significativa melhora nos limites de detecção e sensibilidade. Discrepâncias entre o aumento de sensibilidade verificado e previsto pela lei de Beer têm relação com diferenças de dispersão em celas de 1 e 100 cm. Para a determinação espectrofotométrica de paraquat, foi desenvolvido um módulo de análises com micro-bombas solenóides. Ácido dehidroascórbico foi empregado como reagente, sendo a solução estável por uma semana. Resposta linear foi observada de 0,1 a 5,0 mg L1, r=0,997, com limite de detecção, coeficiente de variação e freqüência de amostragem estimados em 22 µg L-1, 1,0% (n=10) e 63 h-1, respectivamente. Os resultados para amostras de águas foram concordantes com o procedimento de referência (95% de confiança). Para a determinação fluorimétrica de cianeto dissociável em ácidos, foi desenvolvido um módulo de análises com válvulas solenóides, explorando a reação com oftalaldeído e glicina. Sensibilidade 2 vezes maior foi observada com a retenção da zona de amostra por 60 s, com resposta linear entre 1 e 200 µg L-1, r=0,999. O coeficiente de variação, limite de detecção e freqüência de amostragem foram estimados em 1,4% (n=10), 0,5 µg L-1 e 22 h-1, respectivamente. Com prévia etapa de separação por difusão gasosa, o procedimento foi aplicado em amostras de águas naturais, sendo os resultados concordantes com o procedimento de referência ao nível de confiança de 95%. Para a especiação redox de cromo, os procedimentos analíticos foram baseados em sistemas de análises em fluxo com micro-bombas solenóides. O Cr(VI) foi determinado por espectrofotometria de longo caminho óptico com difenilcarbazida. Resposta linear foi observada entre 2 e 40 g L-1, r=0,973. O limite de detecção, coeficiente de variação e freqüência de amostragem foram estimados em 1,8 µg L-1, 0,6% (n=10) e 55 h-1, respectivamente. Quimiluminescência foi utilizada para determinar Cr(III), com resposta linear observada entre 2 e 50 µg L-1, com r=0,999. O limite de detecção, coeficiente de iv variação e freqüência de amostragem foram estimados em 0,38 µg L-1, 3,3% (n=10) e 50 h-1, respectivamente. Oxidação em linha foi também implementada para a determinação espectrofotométrica de cromo total. Em amostras de águas naturais, os resultados foram concordantes para Cr(VI), mas efeitos de matriz foram observados para Cr(III), aparentemente devido à complexação com sustâncias húmicas. / This work aimed the development of analytical procedures based on flow analysis with multicommutation, coupled to detection by fluorescence, long pathlength spectrophotometry or chemiluminescence in liquid-core waveguides (LCW), for determination of environmental pollutants. The developed procedures are in accordance with the requirements of sensitivity and detection limits of the current environmental legislation and the analytical characteristics are in agreement with current trends as low sample and reagents consumption, low waste generation, high sampling rate, low cost and simple operation. The compact flow systems could be adapted for in situ monitoring. Improvements in detection limit and sensitivity were observed by coupling the 100-cm LCW to flow injection analysis and monosegmented flow analysis for turbidimetric and spectrophotometric measurements. Discrepancies between the experimentally evaluated increase in sensitivity and that estimated by the Beers law are related to differences in sample dispersion with 1 and 100 cm flow cells. A multicommuted flow-system with solenoid micro-pumps was used for the spectrophotometric determination of paraquat. The reducing reagent, dehydroascorbic acid, was stable for at least one week. Linear response was observed from 0.1 to 5.0 mg L-1, with r=0.997 and detection limit, coefficient of variation and sampling rate estimated as 22 µg L-1, 1.0% (n=10) and 63 h-1, respectively. The procedure was applied for paraquat determination in water samples, yielding results in agreement with the reference procedure at the 95% confidence level. For the fluorimetric determination of Weak Acid Dissociable Cyanide, a multicommuted flow system was development with solenoid valves, exploiting the reaction with o-phthalaldehyde and glycine. A two-fold higher sensitivity was observed with a 60-s stopped-flow interval, with linear response between 1 and 200 µg L-1, r=0.999. The coefficient of variation, detection limit and sampling rate were estimated as 1.4% (n=10), 0.5 µg L-1 and 22 h-1, respectively. After separation by gas diffusion, the procedure was applied to the analysis of natural water samples, with results in agreement with the reference procedure at the 95% confidence level. For redox chromium speciation, the procedures were based on a multicommuted flow system with solenoid micro-pumps. The determination of Cr(VI) was performed by long pathlength spectrophotometrywith diphenylcarbazide. Linear response was observed between 2 and 40 g L-1, r=0.973. The detection limit, coefficient of variation and sampling rate were estimated as 1.7 g L-1, 0.6% (n=10) and 55 h-1, respectively. Chemiluminescence was used to determine Cr(III), being the linear response observed between 2 and 50 µg L-1, with r=0.999. The detection limit, coefficient of variation and sampling rate were estimated as 0.38 µg L-1, 3.3% (n=10) and 50 h-1, respectively. On-line oxidation was also implemented for the determination of total chromium. In natural water samples, results were consistent for Cr(VI), but matrix vi effects were observed in Cr(III) determination, apparently in view of complexation with humic substances.
26

Desenvolvimento de procedimentos analíticos limpos e com alta sensibilidade para a determinação de espécies de interesse ambiental / Development of clean analytical procedures with high sensitivity for determination of species of environmental interest

Melchert, Wanessa Roberto 28 May 2009 (has links)
Procedimentos analíticos limpos e com alta sensibilidade foram desenvolvidos para a determinação de espécies de interesse ambiental (carbaril, sulfato e cloro livre). Os procedimentos foram baseados no acoplamento de sistemas de análises em fluxo com microbombas solenoides à espectrofotometria com longo caminho óptico ou em procedimentos de extração em ponto nuvem, visando a concentração das espécies de interesse sem o emprego de solventes tóxicos. A determinação de carbaril em águas naturais foi baseada em uma dupla extração em ponto nuvem: uma etapa de clean-up para a remoção de substâncias orgânicas interferentes e outra de pré-concentração do indofenol formado na reação com a forma oxidada do p-aminofenol. Resposta linear foi observada entre 10 e 500 µg L-1, com absortividade molar aparente estimada em 4,6x105 L mol-1 cm-1. O limite de detecção foi estimado em 7 µg L-1 e coeficiente de variação em 3,4% (n = 8). Recuperações entre 91 e 99% foram estimadas para adições de carbaril em amostras de águas naturais. Uma cela simples e de baixo custo com 30 cm de caminho óptico foi construída para medidas espectrofotométricas. A cela apresenta características desejáveis como baixa atenuação do feixe de radiação e volume interno (75 µL) comparável a de uma cela convencional. O desempenho da cela foi avaliado na determinação de fosfato utilizando o método azul de molibdênio com resposta linear obtida entre 0,05 e 0,8 mg L-1 de fosfato (r = 0,999). O aumento na sensibilidade (30,4 vezes) em comparação com o obtido com uma cela de fluxo convencional de 1 cm está de acordo com o estimado pela lei de Lambert-Beer. A formação do indofenol foi também explorada para a determinação de carbaril no procedimento em fluxo com celas de 30 e 100 cm. Respostas lineares; limite de detecção e coeficiente de variação foram estimados entre 50 - 750 e 5 - 200 µg L-1; 4,0 e 1,7 µg L-1 e 2,3 e 0,7%, respectivamente, para as celas de 30 e 100 cm. O procedimento proposto foi seletivo para a determinação de carbaril, sem interferências de outros pesticidas carbamatos. O resíduo gerado foi tratado com persulfato de potássio e irradiação ultravioleta, com redução de 94% do carbono orgânico total, não sendo o resíduo degradado considerado tóxico, frente às bactérias Vibrio-fischeri. A determinação de sulfato foi baseada em medidas turbidimétricas com cela de fluxo de 1 cm, com resposta linear observada entre 20 - 200 mg L-1. Deriva de linha base não foi observada em função do fluxo pulsado gerado pelas microbombas solenoides. O limite de detecção e o coeficiente de variação (n = 20) foram estimados em 3 mg L-1 e 2,4%, respectivamente, com frequência de amostragem de 33 determinações por hora. Para aumentar a sensibilidade, uma cela de fluxo de 100 cm foi empregada e deriva de linha base foi evitada utilizando uma etapa de limpeza periódica com EDTA em meio alcalino. Resposta linear foi observada entre 7 - 16 mg L-1 com limite de detecção de 150 µg L-1 e coeficiente de variação de 3,0% (n = 20). A frequência de amostragem foi estimada em 25 determinações por hora. Resultados obtidos para amostras de águas naturais e de chuva foram concordantes a nível de confiança de 95% com o procedimento turbidimétrico em batelada. A determinação de cloro livre em águas naturais e de torneira foi baseada na reação com N,N-dietil-p-fenilenodiamina, com resposta linear entre 5 e 100 µg L-1 de hipoclorito e limite de detecção e coeficiente de variação estimados em 0,23 µg L-1 e 3,4%, respectivamente. A frequência de amostragem foi estimada em 58 determinações por hora. / Clean analytical procedures with high sensitivity for the determination of species of environmental interest (carbaryl, sulphate and chlorine) were developed. Flow systems with solenoid micropumps were coupled to long optical pathlength spectrophotometry or cloud point extraction procedures, aiming the concentration of species for determination without employing toxic solvents. Carbaryl determination in natural waters was based on a double cloud point extraction: a clean-up step for removal of interfering organic species and pre-concentration of the indophenol blue, formed in the reaction with the oxidized of p-aminophenol. Linear response was observed between 10 and 50 µg L-1, with apparent molar absortivity estimated as 4.6x105 L mol-1 cm-1. Detection limit was estimated as 7 mg L-1 and the coefficient of variation as 3.4% (n = 8). Recoveries between 91 and 99% were obtained for carbaryl spiked to natural waters. A simple and low cost flow cell with 30 cm optical path was constructed for spectrophotometric measurements. The cell shows desirable characteristics such as reduced attenuation of the radiation beam and internal volume (75 µL) comparable to conventional flow cells. The performance was evaluated by phosphate determination by the molibdenium blue method, with linear response between 0.05 and 0.8 mg L-1 of phosphate (r = 0.999). The increase in sensitivity (30.4 fold) in comparison to the obtained with a conventional 1 cm optical path flow cell agreed to theoretical value estimated by the Lambert-Beer law. The determination of carbaryl was also carried out in a flow system coupled to 30 and 100 cm optical path flow cells, also exploiting the formation of indophenol compound. Linear responses, detection limits and coefficients of variation were 50 - 750 and 5 - 200 µg L-1;4.0 and 1.7 µg L-1 and 2.3 and 0.7%, respectively, for 30 and 100 cm cells. The proposed procedure was selective for the determination of carbaryl, without interferences of other carbamate pesticides. The waste of the analytical procedure was treated with potassium persulphate and ultraviolet irradiation, with decrease of 94% of total organic carbon. The residue after treatment was not toxic for Vibrio-fischeri bacteria. Sulphate determination was based on turbidimetric measurements with 1-cm flow cell, with linear response between 20 and 200 mg L-1. Baseline drift was avoided in view of the pulsed flow related to the solenoid micropumps. The detection limit and the coefficient of variation were estimated as 3 mg L-11 and 2.4%, respectively, for a sampling rate of 33 determinations per hour. Aiming the increase in sensitivity, a 100 cm optical path flow cell was employed and baseline drift was avoided with a washing, step employing EDTA in alkaline medium. Linear response was observed between 7 - 16 mg L-1, with a detection limit of 150 µg L-1, coefficient of variation of 3.0% (n = 20) and sampling rate of 25 determinations per hour. Results obtained natural and rain for water samples agreed at 95% confidence level with the batch turbidimetric procedure. The determination of free chlorine in natural and tap waters was based on the reaction with N,N-diethyl-p-phenylenediamine, with linear response between 5 and 100 µg L-1, and detection limit and coefficient of variation estimated as 0.23 µg L-1 and 3.4%, respectively. Sampling rate was estimated as 58 determinations per hour.
27

Desenvolvimento de método analítico visando a pré-concentração em ponto nuvem em linha para determinação de cádmio em amostras ambientais

Akiba, Naomi January 2016 (has links)
Orientadora: Profa. Dra. Ivanise Gaubeur / Dissertação (mestrado) - Universidade Federal do ABC. Programa de Pós-Graduação em Ciência e Tecnologia/Química, 2016. / Os metais cada vez mais poluem o meio ambiente devido as intensas atividades antropogenicas. O cadmio e um metal potencialmente toxico, mesmo em baixas concentracoes, e altamente toxico para os seres humanos, plantas e animais, sendo frequentemente utilizado como indicador de poluicao em aguas. A determinacao do cadmio e geralmente realizada por metodos espectroanaliticos bem estabelecidos. Devido a complexidade das diferentes matrizes ambientais e das baixas concentracoes, algumas amostras necessitam de previa separacao e preconcentracao antes de sua deteccao. A mecanizacao do processo de extracao em ponto nuvem em sistema online permite eventual eliminacao de interferentes, reducao de reagentes utilizados, o aumento da sensibilidade e da precisao, e diminuicao do tempo de analise. Este trabalho propoe a extracao em ponto nuvem em sistema multicomutado de analise em fluxo do complexo formado entre o Cd(II) e (1-(2- piridilazo)-2-naftol) (PAN), utilizando o Triton X-114, com deteccao por espectrometria de absorcao atomica em chama com fonte continua e de alta resolucao (HR-CS FAAS). Foram avaliados alguns parametros relativos a formacao do complexo, a extracao em ponto nuvem e ao sistema multicomutado. Nas melhores condicoes de complexacao e extracao: 4,0 ml da solucao da amostra foram misturados com PAN 311,4 ¿Êmol L-1, Triton X-114 0,6% (m/v) e solucao tampao Tris/Htris+, pH 9.0, , tambem usada para inducao do ponto nuvem, obtendo um volume final de 7,0 mL. A fase rica em tensoativo foi retida em uma minicoluna empacotada com algodao hidrofobico (vazao de 2 mL min-1) e eluida com 300 ¿ÊL de HNO3 0,5 mol L-1 (vazao de 5 ml min- 1). Foi obtida uma curva analitica com faixa linear de 5 . 60 ¿Êg L-1, limite de deteccao de 0,52 ¿Êg L-1, limite de quantificacao 1,7 ¿Êg L-1, coeficiente de variacao de 1,3% (n=12) e fator de enriquecimento igual a 6,6. A frequencia analitica foi de 6 amostras h-1 / Due to intense anthropogenic activities, metal ions are among the most important causer of pollution in the environment. Cadmium even at low concentrations is known to be highly toxic for animals, plants and humans. It is often used as water pollution indicator. Several spectro analytical techniques are available for the trace cadmium. However, due to complexes matrix effects and low concentration there is the necessity of separation and preconcentration procedure before detection. The mechanization of cloud point extraction allows the efficient separation of the analyte. It reduces the amount of sample and reagents, increasing sensitivity, precision, pre-concentration factor and analysis time. This work propose the development of an analytical method by cloud point extraction of Cd(II) and 1-(2 pyridylazo)-2-naphol (PAN) complex using Triton X-114, and detection by means of high-resolution continuum source atomic absorption spectrometry Some parameters related to complex formation, cloud point extraction and multicommuted flow system were evaluated. Under best complexation and extraction conditions: PAN 311.4 mol L-1, Triton X-114 0.6% and Tris/Htris+ buffer solution, pH 9.0, used too cloud point induction, the surfactant rich phase was retained in a hydrophobic cotton packed minicolumn (flow 2 mL min-1) and eluted using 300 ìL HNO3 0.5 mol L-1 solution (flow 5 mL min-1). The analytical curve 5 ¿ 60 ìg L-1 linear range, limit of detection 0.52 ìg L-1-, limit of quantification 1.7 ìg L-1, 1.3% coefficient of variation (n=12) and enhancement factor 6.6 were obtained. The analytical frequency was 6 samples h.1.
28

Materiais inorgânicos associados a sistemas multicomutados para a determinação de espécie químicas em alimentos

LEOTERIO, Dilmo Marques da Silva 21 March 2016 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2017-05-30T13:01:39Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE DILMO MARQUES_2016.pdf: 3410115 bytes, checksum: ef2c4a31a389b0d7af33d59ec444fa24 (MD5) / Made available in DSpace on 2017-05-30T13:01:39Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE DILMO MARQUES_2016.pdf: 3410115 bytes, checksum: ef2c4a31a389b0d7af33d59ec444fa24 (MD5) Previous issue date: 2016-03-21 / CNPQ / Neste trabalho foram desenvolvidos métodos analíticos, baseados no conceito de multicomutação, para análise de espécies químicas em alimentos. Para isto, foram sintetizados dois materiais: um composto de coordenação usado como fase sólida na determinação de açúcares redutores e uma rede de sílica utilizada como resina de pré-concentração de percloratos. O composto de coordenação cobre (II) - 4,4 '- bipiridina foi usado no desenvolvimento do método para a determinação de açúcares redutores em água de coco e sucos empregando sistema em fluxo multicomutado com detecção espectrofotométrica. A metodologia de análise baseou-se na reação de oxi-redução em meio alcalino entre o reagente sólido e os açúcares redutores. A reação entre a fase sólida (de coloração azul) com (glicose + frutose) resulta em produto de cor amarelada, monitorada em 420 nm. A fase sólida foi fixada em 50 mg e temperatura de 90ºC. Com volume de zona de amostragem de 160 L, que corresponde a 20 ciclos, obtendo resposta linear entre 1,0 e 20,0 g L-1 de AR com RSD de 4,47% (n = 7 ), limite de detecção de 0,2250 g L-1, limite de quantificação de 0,7496 g L-1, freqüência analítica de 75 determinções por hora e geração de efluentes de 320 μL por determinação. Os teores de açúcar redutor encontrados em sucos e água de coco variaram de 38,35 a 98,50 g L-1 e 61,80 a 68,70 g L-1 respectivamente. A rede de sílica, 2,5,8,11,14-pentaoxa-1-silaciclotetradecano, foi empregada num sistema multicomutado como coluna de pré-concentração de perclorato. O sistema foi acoplado a um detector potenciométrico para determinar percloratos em vegetais. Usou-se um eletrodo tubular com membrana constituída por 1% (m/m) de BNIP 4,4 Dapm LC1 solubilizado em 68% (m/m) de 2-nitrodifeniléter, como solvente mediador e 31% (m/m) de poli (cloreto de vinila). Obteve-se limite de detecção de 2,8x10-7 mol L-1, resposta linear no intervalo de 1,0x10-9 a 1,0x10-1 mol L-1, coeficiente de correlação linear de 0,9998 e a coluna apresentou uma capacidade de retenção de 2,86x10-3 mol de perclorato. O sistema foi aplicado às amostras de diferentes vegetais e foram encontradas concentrações de percloratos de 1,30 a 5,08 µg L-1 o teste recuperação variou de 96,5 a 110,8 %. / Two new multicommutation-based analytical methods were developed aiming to the quantification of chemical species in food. The first method is intended to the determination of reducing sugars in coconut water and fruit juices, while the second one is a potentiometric determination of perchlorates in horticultural products. The method eveloped for the determination of reducing sugars uses a multicommuted flow system with spectrophotometric detection employing a (copper (II) - 4,4’ – bipyridyl) coordination compound as the solid-phase reagent. The reaction of the solid blue phase with glucose/fructose resulted in a yellowish solution, which was monitored at 420 nm; 50 mg of the solid phase was used and the temperature was set at 90ºC. The volume of the sample zone was, 160 L, corresponding to 20 cycles, with a linear response of 1.0 e 20.0 g L-1 to the RA and RSD of 4.47% (n = 7), detection limit of 0.2250 g L-1, the limit of quantification was 0.7496 g L-1, analytical frequency of 75 determination per hour and effluent generation of 320 L per determination. The potentiometric method used to determine perchlorates used a tubular electrode formed by a polymeric membrane which showed the best features consisted of 1% (w/w) BNIP Dapm LC1 solubilized in 68% (w/w) of 2-nitrodiphenyl ether as a mediator solvent and 31% (w/w) poly(vinyl chloride) as the polymeric matrix. A limit of detection of 2.8x10-7 mol L-1 was obtained with a linear response in the range of 1.0x10-9 at 1.0x10-1 mol L-1, linear correlation coefficient of 0.9998 and the column retention capacity 2.86x10-3 mol perchlorate. Was applied to samples of different vegetables found perchlorates 1.30 to 5.08 µg L-1 and recovery between 96.5 and 110.8%.
29

Desenvolvimento de procedimentos analíticos limpos e com alta sensibilidade para a determinação de espécies de interesse ambiental / Development of clean analytical procedures with high sensitivity for determination of species of environmental interest

Wanessa Roberto Melchert 28 May 2009 (has links)
Procedimentos analíticos limpos e com alta sensibilidade foram desenvolvidos para a determinação de espécies de interesse ambiental (carbaril, sulfato e cloro livre). Os procedimentos foram baseados no acoplamento de sistemas de análises em fluxo com microbombas solenoides à espectrofotometria com longo caminho óptico ou em procedimentos de extração em ponto nuvem, visando a concentração das espécies de interesse sem o emprego de solventes tóxicos. A determinação de carbaril em águas naturais foi baseada em uma dupla extração em ponto nuvem: uma etapa de clean-up para a remoção de substâncias orgânicas interferentes e outra de pré-concentração do indofenol formado na reação com a forma oxidada do p-aminofenol. Resposta linear foi observada entre 10 e 500 µg L-1, com absortividade molar aparente estimada em 4,6x105 L mol-1 cm-1. O limite de detecção foi estimado em 7 µg L-1 e coeficiente de variação em 3,4% (n = 8). Recuperações entre 91 e 99% foram estimadas para adições de carbaril em amostras de águas naturais. Uma cela simples e de baixo custo com 30 cm de caminho óptico foi construída para medidas espectrofotométricas. A cela apresenta características desejáveis como baixa atenuação do feixe de radiação e volume interno (75 µL) comparável a de uma cela convencional. O desempenho da cela foi avaliado na determinação de fosfato utilizando o método azul de molibdênio com resposta linear obtida entre 0,05 e 0,8 mg L-1 de fosfato (r = 0,999). O aumento na sensibilidade (30,4 vezes) em comparação com o obtido com uma cela de fluxo convencional de 1 cm está de acordo com o estimado pela lei de Lambert-Beer. A formação do indofenol foi também explorada para a determinação de carbaril no procedimento em fluxo com celas de 30 e 100 cm. Respostas lineares; limite de detecção e coeficiente de variação foram estimados entre 50 - 750 e 5 - 200 µg L-1; 4,0 e 1,7 µg L-1 e 2,3 e 0,7%, respectivamente, para as celas de 30 e 100 cm. O procedimento proposto foi seletivo para a determinação de carbaril, sem interferências de outros pesticidas carbamatos. O resíduo gerado foi tratado com persulfato de potássio e irradiação ultravioleta, com redução de 94% do carbono orgânico total, não sendo o resíduo degradado considerado tóxico, frente às bactérias Vibrio-fischeri. A determinação de sulfato foi baseada em medidas turbidimétricas com cela de fluxo de 1 cm, com resposta linear observada entre 20 - 200 mg L-1. Deriva de linha base não foi observada em função do fluxo pulsado gerado pelas microbombas solenoides. O limite de detecção e o coeficiente de variação (n = 20) foram estimados em 3 mg L-1 e 2,4%, respectivamente, com frequência de amostragem de 33 determinações por hora. Para aumentar a sensibilidade, uma cela de fluxo de 100 cm foi empregada e deriva de linha base foi evitada utilizando uma etapa de limpeza periódica com EDTA em meio alcalino. Resposta linear foi observada entre 7 - 16 mg L-1 com limite de detecção de 150 µg L-1 e coeficiente de variação de 3,0% (n = 20). A frequência de amostragem foi estimada em 25 determinações por hora. Resultados obtidos para amostras de águas naturais e de chuva foram concordantes a nível de confiança de 95% com o procedimento turbidimétrico em batelada. A determinação de cloro livre em águas naturais e de torneira foi baseada na reação com N,N-dietil-p-fenilenodiamina, com resposta linear entre 5 e 100 µg L-1 de hipoclorito e limite de detecção e coeficiente de variação estimados em 0,23 µg L-1 e 3,4%, respectivamente. A frequência de amostragem foi estimada em 58 determinações por hora. / Clean analytical procedures with high sensitivity for the determination of species of environmental interest (carbaryl, sulphate and chlorine) were developed. Flow systems with solenoid micropumps were coupled to long optical pathlength spectrophotometry or cloud point extraction procedures, aiming the concentration of species for determination without employing toxic solvents. Carbaryl determination in natural waters was based on a double cloud point extraction: a clean-up step for removal of interfering organic species and pre-concentration of the indophenol blue, formed in the reaction with the oxidized of p-aminophenol. Linear response was observed between 10 and 50 µg L-1, with apparent molar absortivity estimated as 4.6x105 L mol-1 cm-1. Detection limit was estimated as 7 mg L-1 and the coefficient of variation as 3.4% (n = 8). Recoveries between 91 and 99% were obtained for carbaryl spiked to natural waters. A simple and low cost flow cell with 30 cm optical path was constructed for spectrophotometric measurements. The cell shows desirable characteristics such as reduced attenuation of the radiation beam and internal volume (75 µL) comparable to conventional flow cells. The performance was evaluated by phosphate determination by the molibdenium blue method, with linear response between 0.05 and 0.8 mg L-1 of phosphate (r = 0.999). The increase in sensitivity (30.4 fold) in comparison to the obtained with a conventional 1 cm optical path flow cell agreed to theoretical value estimated by the Lambert-Beer law. The determination of carbaryl was also carried out in a flow system coupled to 30 and 100 cm optical path flow cells, also exploiting the formation of indophenol compound. Linear responses, detection limits and coefficients of variation were 50 - 750 and 5 - 200 µg L-1;4.0 and 1.7 µg L-1 and 2.3 and 0.7%, respectively, for 30 and 100 cm cells. The proposed procedure was selective for the determination of carbaryl, without interferences of other carbamate pesticides. The waste of the analytical procedure was treated with potassium persulphate and ultraviolet irradiation, with decrease of 94% of total organic carbon. The residue after treatment was not toxic for Vibrio-fischeri bacteria. Sulphate determination was based on turbidimetric measurements with 1-cm flow cell, with linear response between 20 and 200 mg L-1. Baseline drift was avoided in view of the pulsed flow related to the solenoid micropumps. The detection limit and the coefficient of variation were estimated as 3 mg L-11 and 2.4%, respectively, for a sampling rate of 33 determinations per hour. Aiming the increase in sensitivity, a 100 cm optical path flow cell was employed and baseline drift was avoided with a washing, step employing EDTA in alkaline medium. Linear response was observed between 7 - 16 mg L-1, with a detection limit of 150 µg L-1, coefficient of variation of 3.0% (n = 20) and sampling rate of 25 determinations per hour. Results obtained natural and rain for water samples agreed at 95% confidence level with the batch turbidimetric procedure. The determination of free chlorine in natural and tap waters was based on the reaction with N,N-diethyl-p-phenylenediamine, with linear response between 5 and 100 µg L-1, and detection limit and coefficient of variation estimated as 0.23 µg L-1 and 3.4%, respectively. Sampling rate was estimated as 58 determinations per hour.
30

Desenvolvimento de instrumentação e procedimentos analíticos automáticos empregando fotometria em fase sólida para determinação de zinco em produtos farmacêuticos e água / Combining multicommuted flow injection analysis and solid phase photometry for the determination of zinc in pharmaceutical preparation and water

Tuanne dos Reis Dias 25 August 2010 (has links)
Neste trabalho, é proposto o desenvolvimento de instrumentação e procedimentos analíticos automáticos empregando fotometria em fase sólida para determinação de zinco em produtos farmacêuticos e água. Para implementação do procedimento analítico, todo o sistema foi acoplado a um computador através de uma interface eletrônica. Um software escrito em linguagem QuickBASIC 4.5 permite que o computador efetue o controle da adição das soluções da amostra e do eluente e faça aquisição de dados. O sistema de detecção é constituído de uma cela de fluxo contendo, um LED e um fotodiodo. A geometria da cela de fluxo possibilitava variar o comprimento do caminho óptico. O procedimento para determinação do zinco foi baseado na retenção do analito na fase sólida (TAN-C18), previamente inserida na cela de fluxo, seguido de uma etapa de eluição. Com os parâmetros analíticos otimizados obteve-se resposta linear na faixa de 0,05 a 0,85 mg L-1 (R=0,995), limite detecção de 9,3 \'mü\'g L-1, coeficiente de variação de 1,4% (n=10) e frequência de amostragem de 36 det h-1. O módulo de análise foi aplicado em amostras de produtos farmacêuticos e a exatidão dos resultados foi averiguada comparando com os resultados obtidos por espectrometria de emissão óptica com plasma acoplado indutivamente ICP-OES. Aplicando-se tratamento estatístico apropriado, observou-se que não havia diferença significativa ao nível de confiança de 95 %. Estes resultados comprovam a viabilidade do emprego de fotômetro de LED em fotometria em fase sólida / In this work, it is propose the instrumentation and automatic analytic procedures development using solid phase spectrophotometry for determination of zinc in pharmaceutical preparations and water. For analytic procedure implementation, the whole system was coupled to a computer through an electronic interface. A written software in language QuickBASIC 4.5 allows the computer makes the sample solutions addition control and of eluent and do data acquisition. The detection system is constituted of a flow cell contend, a LED and a photodiode. The flow cell geometry enabled vary the length of the optical path. The procedure for zinc determination was going based in analyte retention in the solid phase (TAN-C18), previously inserted in the flow cell, followed by an elution stage. With the optimized analytic parameters it btained lineal answer in the band of 0,05 to 0,85 mg L-1 (R=0,995), limit detection of 9,3 \'mü\'g L-1, variation coefficient of 1,4% (n=10) and sampling throughput of 36 det h-1. The analysis module was going applied in pharmaceutical preparations samples and the exactness of the results was going ascertained comparing with the results obtained for inductively coupled plasma optic emission spectrometry of with ICP- its. Applying appropriated statistical treatment, it observed that there wasn\'t significant difference to the reliable level of 95 %. These results prove photometer job viability of LED in photometry in solid phase

Page generated in 0.219 seconds