• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento de método analítico por cromatografia líquida para determinação de impurezas no iodixanol / Analytical method development by high performace liquid chromatography for determination of impurities in iodixanol

Rondon, Bruno Doratioto 17 October 2013 (has links)
Made available in DSpace on 2016-06-02T20:37:48Z (GMT). No. of bitstreams: 1 5597.pdf: 3304343 bytes, checksum: 0c450aff960d822ff2236d773f596f7f (MD5) Previous issue date: 2013-10-17 / This work describes for the first time an isocratic method in a single analytical run to quantify deacetyl iodixanol (iodixanol related compound C), iopentol (iodixanol related compound D) and cyclized iodixanol (iodixanol related compound E), as impurities in iodixanol. Iodixanol is a drug substance, dimeric, nonionic, water-soluble, used as a radiographic contrast medium, which is administered by intravascular injection. The impurities A and B were not evaluated in this work, since they are not commercially available as standards. The method was also validated for the quantitative assay, since there is no chromatographic method described in the current USP compendium for the assay. The impurities can be formed during the synthesis process of iodixanol, and it is important to quantify them due to their related toxicity. In this work, the reverse and hydrophilic interaction (HILIC) modes of elution were evaluated. The hydrophilic elution mode was selected due to good efficiency and selectivity. In both modes of elution, columns having the technology fused-core were used, since they demonstrate high efficiency due to their better mass transfer in comparison to conventional HPLC columns. The chromatographic separation was carried out on a kinetex® HILIC column (150 x 4.6 mm; 2.6 μm) at 20 °C using acetonitrile-formic acid (pH 3.2; 1.0 mmol L-1) (92:08, v/v) at a flow rate of 0.8 mL/min. The compounds were monitored at 243 nm and the total time of analysis was 45 min. The method was validated in accordance with the current ICH guidelines for determination of impurities which include selectivity, linearity, accuracy, precision, limits of quantification and detection and robustness. The limits of quantification (LOQ) were 0.479; 0.0606 and 0.133 μg/mL for the impurities C, D and E, respectively. Furthermore, the validated methods were tested in iodixanol samples. The test results of the analyses of impurities and assay in those samples are presented and discussed accordingly. / Este trabalho descreve pela primeira vez um método isocrático em uma única corrida analítica para quantificação das impurezas deacetil iodixanol (iodixanol composto relacionado C), iopentol (iodixanol composto relacionado D) e iodixanol ciclizado (iodixanol composto relacionado E) na matéria-prima iodixanol. Iodixanol é um composto dímerico, não-iônico, solúvel em água, usado para contraste para raios X com administração intravascular. As impurezas A e B não foram avaliadas neste trabalho, uma vez que não existem padrões disponíveis comercialmente dos mesmos. O método também foi validado para a quantificação de teor, uma vez que não existe método cromatográfico descrito no compêndio atual da USP para o teor. Estas impurezas podem ser formadas durante a síntese do iodixanol, e a importância da quantificação destas está relacionada à toxicidade. Neste trabalho foram avaliados os modos de eluição reverso e por interação hidrofílica (HILIC). O modo HILIC foi o selecionado, pois ofereceu boa eficiência cromatográfica com boa seletividade. Em ambos os modos, o uso de colunas de tecnologia fused-core foi empregado, por apresentar alta eficiência devido à sua melhor transferência de massa em comparação com as colunas analíticas convencionais. A separação cromatográfica foi conduzida utilizando-se a coluna analítica kinetex® HILIC (150 x 4,6 mm; 2,6 μm) a 20 °C e acetonitrila ácido fórmico (pH 3,2; 1,0 mmol L-1) (92:08, v/v) com 0,8 mL/min de vazão. Os compostos foram monitorados a 243 nm e o tempo total de análise foi de 45 min. Os métodos foram validados em acordo com as recomendações atuais do ICH para a determinação de impurezas, nas quais incluem seletividade, linearidade, exatidão, precisão, limites de quantificação e de detecção, e robustez. Os limites de quantificação foram de 0,479; 0,0606 e 0,133 μg/mL para as impurezas C, D e E, respectivamente. Deste modo, os métodos validados foram aplicados em amostras de iodixanol. Os resultados para a análise de impurezas e teor nestas amostras são, portanto, apresentados e discutidos.
2

Estratégias para aumento de sensibilidade e seletividade de separações cromatográficas em sistemas de análises em fluxo / Strategies to improve sensitivity and selectivity of chromatographic separations in flow analysis systems

Batista, Alex Domingues 10 December 2014 (has links)
A introdução de separações cromatográficas expandiu a aplicabilidade de sistemas de análises em fluxo. No entanto, a seletividade e sensibilidade de procedimentos são restritos devido à escassa disponibilidade de fases estacionárias que operam a baixas pressões. Sendo assim, foram desenvolvidos quatro procedimentos analíticos visando a melhoria destes aspectos. A primeira proposta explorou pioneiramente colunas de núcleo fundido em sistemas de análises por injeção em fluxo. A separação de metil, etil e propil parabenos foi selecionada com aplicação. As eficiências cromatográficas de quatro colunas (C18, RPamida, F5 e fenil-hexil) foram avaliadas criticamente. Acetonitrila e uma solução de ácido fosfórico pH 2,5 foram utilizadas como fase móvel. A fase RP-amida apresentou melhor desempenho com a separação dos três analitos em 8,0 min, com resoluções > 1,72, simetrias de pico < 1,66, LOD entre 0,12 e 0,39 mg L-1, resposta linear até 5,0 mg L-1 (r > 0,996) e CV para altura dos picos < 3,5 % (n=10). O procedimento foi aplicado à determinação de parabenos em produtos de cuidados pessoais e os resultados concordaram com o procedimento de referência a 95% de confiança. Um procedimento envolvendo o acoplamento de extração em fase sólida (SPE) a um sistema de cromatografia por injeção sequencial (SIC) foi proposto para pré-concentração e separação de oito sulfonamidas. A fase estacionária pentafluorofenilpropil foi selecionada após comparação crítica da eficiência apresentada por três colunas de núcleo fundido e duas colunas de fases monolíticas. Acetonitrila e tampão fosfato (pH 5,0) foram utilizados como fase. Fatores de enriquecimento de até 39,2 foram alcançados com volume de amostra de 500 ?L. O procedimento apresentou tempo de análise < 10,5 min, resoluções > 1,83 com simetrias de pico <= 1,52, LOD entre 4,9 e 27 ?g L-1, faixa de resposta linear entre 30,0 e 1000,0 ?g L-1 (r > 0,997) e CV da altura dos picos, 2,9% (n=6). Um procedimento empregando fase estacionária micelar foi desenvolvido para determinação de melamina em leite. A fase móvel foi composta por uma solução aquosa de dodecil sulfato de sódio (SDS) e 1-propanol (92,5:7,5 v/v). O procedimento de preparo de amostra foi implementado em linha pela diluição da amostra com SDS. Resposta linear foi observada entre 2,0 e 6,0 mg L-1 de melamina com LOD estimado em 0,6 mg L-1 e CV da altura dos picos de 2,9% (n=6). Os resultados para diferentes amostras de leite foram concordantes com aqueles obtidos pelo procedimento cromatográfico de referência em um nível de 95% de confiança. Uma estratégia envolvendo pré-concentração on-column de parabenos em um sistema SIC foi proposta. Resposta linear foi observada entre 0,25 e 1,00 ?g mL-1 (r >= 0,999) e LODs estimados entre 40 e 60 ng mL-1. Tempos de retenção e altura dos picos apresentaram CV < 2,1%. Fatores de enriquecimento entre 30,0 e 34,8 foram alcançados. As estratégias propostas são viáveis para melhoria de seletividade e sensibilidade de separações cromatográficas em sistemas de análises em fluxo, além de apresentarem vantagens frente a procedimentos análogos na literatura / The introduction of chromatographic separations expanded the applicability of flow systems. However, selectivity and sensitivity of the procedures are limited due the poor options of stationary phases available for low-pressure. Therefore, four procedures were developed aiming the improvement of these aspects. The first proposal exploited pioneered fused-core columns in a flow injection analysis system. The separation of methyl, ethyl and propel parabens was selected as an application. The chromatographic efficiency of four columns (C18, RP-amide, F5 and fenyl-hexyl) were crítically evaluated. Acetonitrile and a phosphoric acid solution at pH 2.5 were used as mobile phase at different proportions for each column. The RP-amide phase presented the best performance by separating the analytes in 8.0 min with resolution > 1.72, peak symmetry < 1.66, LOD between 0.12-0.39 mg L-1, linear response range up to 5.0 mg L-1 (r > 0.996) and coefficients of variation of peak heights < 3.5% (n=10). The procedure was applied to parabens determination in personal care products and the results agreed with the HPLC reference procedure at the 95% confidence level. A procedure coupling solid phase extraction (SPE) to a sequential injection chromatography (SIC) was proposed for preconcentration and separation of eight sulfonamides. The pentafluorophenylpropyl (F5) phase was selected after a critical comparison of the performance achieved by three fused-core columns and two monolithic columns. Acetonitrile and acetate buffer pH 5.0 were used as mobile phase. Enrichment factors up to 39.2 were achieved with a 500 ?L sample volume. The developed procedure showed analysis time < 10.5 min, resolutions > 1.83 with peak symmetry <= 1.52, LODs between 4.9 and 27 ?g L-1, linear response ranges from 30.0 to 1000.0 ?g L-1 (r > 0.997) and CV of peak heights < 2.9% (n=6). Micelar chromatography was for the first time exploited in SIC and the performance was demonstrated by determination of melamine in milk. Mobile phase was composed by a sodium dodecyl sulfate (SDS) solution and propanol (92.5:7.5). The sample pretreatment procedure was on-line implemented by dilution of the sample with SDS. A linear response was observed within 2.0 and 6.0 mg L-1 of melamine with a LOD estimated at 0.6 mg L-1 and coefficients of variation at 2.9% (n=6). Results for different milk samples agreed with those obtained by high performance liquid chromatography at the 95% confidence level. A procedure involved on-column preconcentration of parabens in a SIC system was based on the injection of relatively high volume of an aqueous sample in a reversed-phase column. After preconcentration, a suitable mobile phase was inserted to perform chromatographic separation (acetonitrile/phosphoric acid pH 2.5 (75:25, v/v)). A linear response was achieved from 0.25 to 1.00 ?g mL-1 (r > 0.999) and LOD estimated within 40 and 80 ng mL-1. Coefficients of variation for retention time and peak heights were below 2.1%. Enrichment factors within 30.0 and 34.8 were achieved. The proposed strategies are feasible for improving selectivity and sensitivity of chromatographic separations in flow analysis systems, besides having advantages compared to similar procedures in the literature
3

Estratégias para aumento de sensibilidade e seletividade de separações cromatográficas em sistemas de análises em fluxo / Strategies to improve sensitivity and selectivity of chromatographic separations in flow analysis systems

Alex Domingues Batista 10 December 2014 (has links)
A introdução de separações cromatográficas expandiu a aplicabilidade de sistemas de análises em fluxo. No entanto, a seletividade e sensibilidade de procedimentos são restritos devido à escassa disponibilidade de fases estacionárias que operam a baixas pressões. Sendo assim, foram desenvolvidos quatro procedimentos analíticos visando a melhoria destes aspectos. A primeira proposta explorou pioneiramente colunas de núcleo fundido em sistemas de análises por injeção em fluxo. A separação de metil, etil e propil parabenos foi selecionada com aplicação. As eficiências cromatográficas de quatro colunas (C18, RPamida, F5 e fenil-hexil) foram avaliadas criticamente. Acetonitrila e uma solução de ácido fosfórico pH 2,5 foram utilizadas como fase móvel. A fase RP-amida apresentou melhor desempenho com a separação dos três analitos em 8,0 min, com resoluções > 1,72, simetrias de pico < 1,66, LOD entre 0,12 e 0,39 mg L-1, resposta linear até 5,0 mg L-1 (r > 0,996) e CV para altura dos picos < 3,5 % (n=10). O procedimento foi aplicado à determinação de parabenos em produtos de cuidados pessoais e os resultados concordaram com o procedimento de referência a 95% de confiança. Um procedimento envolvendo o acoplamento de extração em fase sólida (SPE) a um sistema de cromatografia por injeção sequencial (SIC) foi proposto para pré-concentração e separação de oito sulfonamidas. A fase estacionária pentafluorofenilpropil foi selecionada após comparação crítica da eficiência apresentada por três colunas de núcleo fundido e duas colunas de fases monolíticas. Acetonitrila e tampão fosfato (pH 5,0) foram utilizados como fase. Fatores de enriquecimento de até 39,2 foram alcançados com volume de amostra de 500 ?L. O procedimento apresentou tempo de análise < 10,5 min, resoluções > 1,83 com simetrias de pico <= 1,52, LOD entre 4,9 e 27 ?g L-1, faixa de resposta linear entre 30,0 e 1000,0 ?g L-1 (r > 0,997) e CV da altura dos picos, 2,9% (n=6). Um procedimento empregando fase estacionária micelar foi desenvolvido para determinação de melamina em leite. A fase móvel foi composta por uma solução aquosa de dodecil sulfato de sódio (SDS) e 1-propanol (92,5:7,5 v/v). O procedimento de preparo de amostra foi implementado em linha pela diluição da amostra com SDS. Resposta linear foi observada entre 2,0 e 6,0 mg L-1 de melamina com LOD estimado em 0,6 mg L-1 e CV da altura dos picos de 2,9% (n=6). Os resultados para diferentes amostras de leite foram concordantes com aqueles obtidos pelo procedimento cromatográfico de referência em um nível de 95% de confiança. Uma estratégia envolvendo pré-concentração on-column de parabenos em um sistema SIC foi proposta. Resposta linear foi observada entre 0,25 e 1,00 ?g mL-1 (r >= 0,999) e LODs estimados entre 40 e 60 ng mL-1. Tempos de retenção e altura dos picos apresentaram CV < 2,1%. Fatores de enriquecimento entre 30,0 e 34,8 foram alcançados. As estratégias propostas são viáveis para melhoria de seletividade e sensibilidade de separações cromatográficas em sistemas de análises em fluxo, além de apresentarem vantagens frente a procedimentos análogos na literatura / The introduction of chromatographic separations expanded the applicability of flow systems. However, selectivity and sensitivity of the procedures are limited due the poor options of stationary phases available for low-pressure. Therefore, four procedures were developed aiming the improvement of these aspects. The first proposal exploited pioneered fused-core columns in a flow injection analysis system. The separation of methyl, ethyl and propel parabens was selected as an application. The chromatographic efficiency of four columns (C18, RP-amide, F5 and fenyl-hexyl) were crítically evaluated. Acetonitrile and a phosphoric acid solution at pH 2.5 were used as mobile phase at different proportions for each column. The RP-amide phase presented the best performance by separating the analytes in 8.0 min with resolution > 1.72, peak symmetry < 1.66, LOD between 0.12-0.39 mg L-1, linear response range up to 5.0 mg L-1 (r > 0.996) and coefficients of variation of peak heights < 3.5% (n=10). The procedure was applied to parabens determination in personal care products and the results agreed with the HPLC reference procedure at the 95% confidence level. A procedure coupling solid phase extraction (SPE) to a sequential injection chromatography (SIC) was proposed for preconcentration and separation of eight sulfonamides. The pentafluorophenylpropyl (F5) phase was selected after a critical comparison of the performance achieved by three fused-core columns and two monolithic columns. Acetonitrile and acetate buffer pH 5.0 were used as mobile phase. Enrichment factors up to 39.2 were achieved with a 500 ?L sample volume. The developed procedure showed analysis time < 10.5 min, resolutions > 1.83 with peak symmetry <= 1.52, LODs between 4.9 and 27 ?g L-1, linear response ranges from 30.0 to 1000.0 ?g L-1 (r > 0.997) and CV of peak heights < 2.9% (n=6). Micelar chromatography was for the first time exploited in SIC and the performance was demonstrated by determination of melamine in milk. Mobile phase was composed by a sodium dodecyl sulfate (SDS) solution and propanol (92.5:7.5). The sample pretreatment procedure was on-line implemented by dilution of the sample with SDS. A linear response was observed within 2.0 and 6.0 mg L-1 of melamine with a LOD estimated at 0.6 mg L-1 and coefficients of variation at 2.9% (n=6). Results for different milk samples agreed with those obtained by high performance liquid chromatography at the 95% confidence level. A procedure involved on-column preconcentration of parabens in a SIC system was based on the injection of relatively high volume of an aqueous sample in a reversed-phase column. After preconcentration, a suitable mobile phase was inserted to perform chromatographic separation (acetonitrile/phosphoric acid pH 2.5 (75:25, v/v)). A linear response was achieved from 0.25 to 1.00 ?g mL-1 (r > 0.999) and LOD estimated within 40 and 80 ng mL-1. Coefficients of variation for retention time and peak heights were below 2.1%. Enrichment factors within 30.0 and 34.8 were achieved. The proposed strategies are feasible for improving selectivity and sensitivity of chromatographic separations in flow analysis systems, besides having advantages compared to similar procedures in the literature

Page generated in 0.0419 seconds