• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 14
  • 12
  • 8
  • 1
  • Tagged with
  • 35
  • 35
  • 20
  • 14
  • 6
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Taktile Illusionen Wahrnehmung und neuronale Analyse spatiotemporaler Reizmuster /

Stolle, Annette Margarete. January 2004 (has links)
Mannheim, Univ., Diss., 2004.
22

Schnelle 1-NMR-spektroskopische Bildgebung mittels angepaßter Phasenkodierung der chemischen Verschiebung

Ebel, Andreas. Unknown Date (has links)
Universiẗat, Diss., 1999--Bremen.
23

Entwicklung und Optimierung von Bildgebungssequenzen für die 1H-Magnetresonanztomographie der Lunge

Pracht, Eberhard January 2007 (has links) (PDF)
No abstract available
24

Non-Cartesian Parallel Magnetic Resonance Imaging / Nicht kartesische parallele Magnetresonanz-Bildgebung

Heidemann, Robin January 2008 (has links) (PDF)
Besides image contrast, imaging speed is probably the most important consideration in clinical magnetic resonance imaging (MRI). MR scanners currently operate at the limits of potential imaging speed, due to technical and physiological problems associated with rapidly switched gradient systems. Parallel imaging (parallel MRI or pMRI) is a method which allows one to significantly shorten the acquisition time of MR images without changing the contrast behavior of the underlying MR sequence. The accelerated image acquisition in pMRI is accomplished without relying on more powerful technical equipment or exceeding physiological boundaries. Because of these properties, pMRI is currently employed in many clinical routines, and the number of applications where pMRI can be used to accelerate imaging is increasing. However, there is also growing criticism of parallel imaging in certain applications. The primary reason for this is the intrinsic loss in the SNR due to the accelerated acquisition. In addition, other effects can also lead to a reduced image quality. Due to unavoidable inaccuracies in the pMRI reconstruction process, local and global errors may appear in the final reconstructed image. The local errors are visible as noise enhancement, while the global errors result in the so-called fold-over artifacts. The appearance and strength of these negative effects, and thus the image quality, depend upon different factors, such as the parallel imaging method chosen, specific parameters in the method, the sequence chosen, as well as specific sequence parameters. In general, it is not possible to optimize all of these parameters simultaneously for all applications. The application of parallel imaging in can lead to very pronounced image artifacts, i.e. parallel imaging can amplify errors. On the other hand, there are applications such as abdominal MR or MR angiography, in which parallel imaging does not reconstruct images robustly. Thus, the application of parallel imaging leads to errors. In general, the original euphoria surrounding parallel imaging in the clinic has been dampened by these problems. The reliability of the pMRI methods currently implemented is the main criticism. Furthermore, it has not been possible to significantly increase the maximum achievable acceleration with parallel imaging despite major technical advances. An acceleration factor of two is still standard in clinical routine, although the number of independent receiver channels available on most MR systems (which are a basic requirement for the application of pMRI) has increased by a factor of 3-6 in recent years. In this work, a novel and elegant method to address this problem has been demonstrated. The idea behind the work is to combine two methods in a synergistic way, namely non-Cartesian acquisition schemes and parallel imaging. The so-called non-Cartesian acquisition schemes have several advantages over standard Cartesian acquisitions, in that they are often faster and less sensitive to physiological noise. In addition, such acquisition schemes are very robust against fold-over artifacts even in the case of vast undersampling of k-space. Despite the advantages described above, non-Cartesian acquisition schemes are not commonly employed in clinical routines. A reason for that is the complicated reconstruction techniques which are required to convert the non-Cartesian data to a Cartesian grid before the fast Fourier transformation can be employed to arrive at the final MR image. Another reason is that Cartesian acquisitions are routinely accelerated with parallel imaging, which is not applicable for non-Cartesian MR acquisitions due to the long reconstruction times. This negates the speed advantage of non-Cartesian acquisition methods. Through the development of the methods presented in this thesis, reconstruction times for accelerated non-Cartesian acquisitions using parallel imaging now approach those of Cartesian images. In this work, the reliability of such methods has been demonstrated. In addition, it has been shown that higher acceleration factors can be achieved with such techniques than possible with Cartesian imaging. These properties of the techniques presented here lead the way for an implementation of such methods on MR scanners, and thus also offer the possibility for their use in clinical routine. This will lead to shorter examination times for patients as well as more reliable diagnoses. / Neben dem Bildkontrast ist die Aufnahmegeschwindigkeit die entscheidende Größe für die klinische Anwendung der Magnetresonanz-Tomographie (MRT). Heutzutage arbeiten MR-Tomographen bereits häufig am Limit dessen, was technisch möglich und physiologisch noch vertretbar ist. Die parallele Bildgebung (parallele MRT, pMRT) ist ein Verfahren, welches es ermöglicht, die Aufnahmezeiten von MRT-Bildern signifikant zu verkürzen, ohne dabei das Kontrastverhalten der zu Grunde liegenden MR Sequenz zu verändern. Die beschleunigte Bildakquisition in der pMRT wird erzielt, ohne auf eine leistungsfähigere technische Ausstattung der MR-Tomographen angewiesen zu sein und ohne dabei die physiologischen Grenzwerte zu überschreiten. Wegen dieser Eigenschaften wird die pMRT heutzutage vielfach in der klinischen Routine eingesetzt. Dabei wächst die Zahl der klinischen MR Anwendungen, welche mittels paralleler Bildgebung beschleunigt werden. Neben dieser Entwicklung ist heutzutage aber auch eine zunehmende Kritik am Einsatz der parallelen Bildgebung bei bestimmten Applikationen festzustellen. Ein Hauptgrund dafür ist der intrinsische Verlust an Signal-Rausch-Verhältnis durch die beschleunigte Akquisition. Es gibt weitere Effekte, welche die Bildqualität vermindern können. Durch unvermeidbare Ungenauigkeiten bei den Verfahren der pMRT kann es zu lokalen und zu globalen Fehlern in den rekonstruierten Bildern kommen. Die lokalen Fehler sind als Rauschverstärkung sichtbar, wohingegen die globalen Fehler zu so genannten Faltungsartefakten im Bild führen. Das Auftreten und die Stärke dieser Störeffekte hängen von unterschiedlichen Parametern ab. Im Allgemeinen ist es nicht möglich alle Abhängigkeiten für jede Applikation gleichzeitig zu optimieren. Der Einsatz der parallelen Bildgebung kann zu massiven Bildartefakten führen, d.h. die parallele Bildgebung kann Fehler verstärken. Auf der anderen Seite gibt es Applikationen, wie zum Beispiel die abdominelle MR-Bildgebung oder die MR-Angiographie, bei denen die pMRT nicht zuverlässig funktioniert. Die Anwendung der pMRT verursacht also erst die Fehler. Ganz allgemein kann im klinischen Umfeld beobachtet werden, dass die anfängliche Euphorie gegenüber der parallelen Bildgebung einer gewissen Ernüchterung gewichen ist. Der Zuverlässigkeit der implementierten pMRT-Methoden gilt dabei die Hauptkritik. Des Weiteren ist es nicht gelungen, trotz großen technischen Fortschritts, die maximal zu erreichende Beschleunigung mittels paralleler Bildgebung signifikant zu erhöhen. Standard in der klinischen Routine ist immer noch ein Beschleunigungsfaktor von zwei, obwohl sich die Anzahl der unabhängigen Empfangskanäle eines MR Systems (eine Grundvoraussetzung für die Verwendung der pMRT) in den letzten Jahren um einen Faktor 3-6 erhöht hat. In dieser Arbeit wurde erstmalig gezeigt, dass es eine elegante Möglichkeit gibt, diese Probleme zu adressieren. Die Idee besteht darin, Synergieeffekte zu nutzen, die aus einer Kombination von so genannten nicht-kartesischen Abtastverfahren mit der parallelen Bildgebung entstehen. Die nicht-kartesischen Aufnahmeverfahren haben gegenüber den herkömmlichen kartesischen Verfahren einige Vorteile. Sie sind in der Regel schneller und weniger empfindlich für physiologisches Rauschen als kartesische Aufnahmeverfahren. Außerdem sind sie sehr robust gegenüber Faltungsartefakten, selbst bei starker Unterabtastung der k Raumdaten. Trotz der eben beschriebenen Vorteile finden nicht-kartesische Aufnahmeverfahren kaum Verwendung in der klinischen Routine. Ein Grund hierfür sind die komplexen Rekonstruktionsverfahren, die an Stelle der schnellen Fourier-Transformation angewendet werden müssen, um ein MR-Bild aus nicht-kartesischen Daten zu erzeugen. Ein weiterer Grund liegt darin, dass kartesische MR-Aufnahmen mittlerweile routinemäßig mit paralleler Bildgebung beschleunigt werden, wohingegen dies bei nicht-kartesischen MR-Aufnahmen wegen der langen Rekonstruktionszeiten nicht praktikabel ist. Dadurch wird der oben erwähnte Geschwindigkeitsvorteil der nicht-kartesischen Verfahren irrelevant. Durch die Entwicklung der in dieser Doktorarbeit vorgestellten Methoden konnten erstmals Rekonstruktionszeiten in der nicht-kartesischen Bildgebung erzielt werden, die vergleichbar sind mit denen in der kartesischen Bildgebung. In der vorliegenden Arbeit konnte die höhere Zuverlässigkeit dieser neuen Verfahren demonstriert werden. Des Weiteren wurde gezeigt, dass höhere Beschleunigungsfaktoren erzielt werden können als dies mit kartesischen Verfahren bisher möglich war. Diese Eigenschaften der vorgestellten Methoden bahnen den Weg für eine Implementierung solcher Verfahren an MR Geräten und damit deren Anwendung in der klinischen Routine. Letztendlich wird dies zu kürzeren Untersuchungszeiten der Patienten und zuverlässigeren Diagnosen führen.
25

Einfluss des Hepatozytenwachstumsfaktors(HGF) auf das linksventrikuläre Remodeling: Charakterisierung von Geometrie, Mechanik und Narbenentwicklung mittels NMR-Technik / The Influence of Hepatocyte Growth Factor (HGF) on Ventricular Remodeling: Characterization of Geometry, Mechanics and Scar Formation with NMR

Bathe, Katharina January 2006 (has links) (PDF)
Diese Dissertation beschreibt den Einfluss von HGF auf das ventrikuläre Remodeling des Rattenherzens in der 1. und 16. Woche nach Ischämie und Reperfusion. Die funktionalen Parameter wurden mit Hilfe des NMR gemessen. In der 16. Woche nach Ischämie und Reperfusion wurde die histologisch ermittelte Narbengröße mit dem Wert, der mittels NMR ermittelt wurde, verglichen. / This dissertation describes the influence of HGF on ventricular cardial remodeling of rats one week and sixteen weeks after ischemia and reperfusion. The functional parameters were calculated with NMR. Sixteen weeks after ischemia and reperfusion the scar formation was also analyzed by histologic methods. The outcomes of this method were compared with the results of the measurement with NMR.
26

Chondrogenic differentiation of human mesenchymal stem cells and articular cartilage reconstruction / Chondrogene Differenzierung humaner mesenchymaler Stammzellen und Gelenkknorpelrekonstruktion

Heymer, Andrea January 2008 (has links) (PDF)
Articular cartilage defects are still one of the major challenges in orthopedic and trauma surgery. Today, autologous chondrocyte transplantation (ACT), as a cell-based therapy, is an established procedure. However, one major limitation of this technique is the loss of the chondrogenic phenotype during expansion. Human mesenchymal stem cells (hMSCs) have an extensive proliferation potential and the capacity to differentiate into chondrocytes when maintained under specific conditions. They are therefore considered as candidate cells for tissue engineering approaches of functional cartilage tissue substitutes. First in this study, hMSCs were embedded in a collagen type I hydrogel to evaluate the cartilaginous construct in vitro. HMSC collagen hydrogels cultivated in different culture media showed always a marked contraction, most pronounced in chondrogenic differentiation medium supplemented with TGF-ß1. After stimulation with chondrogenic factors (dexamethasone and TGF-ß1) hMSCs were able to undergo chondrogenesis when embedded in the collagen type I hydrogel, as evaluated by the temporal induction of cartilage-specific gene expression. Furthermore, the cells showed a chondrocyte-like appearance and were homogeneously distributed within a proteoglycan- and collagen type II-rich extracellular matrix, except a small area in the center of the constructs. In this study, chondrogenic differentiation could not be realized with every hMSC preparation. With the improvement of the culture conditions, e.g. the use of a different FBS lot in the gel fabrication process, a higher amount of cartilage-specific matrix deposition could be achieved. Nevertheless, the large variations in the differentiation capacity display the high donor-to-donor variability influencing the development of a cartilaginous construct. Taken together, the results demonstrate that the collagen type I hydrogel is a suitable carrier matrix for hMSC-based cartilage regeneration therapies which present a promising future alternative to ACT. Second, to further improve the quality of tissue-engineered cartilaginous constructs, mechanical stimulation in specific bioreactor systems are often employed. In this study, the effects of mechanical loading on hMSC differentiation have been examined. HMSC collagen hydrogels were cultured in a defined chondrogenic differentiation medium without TGF-ß1 and subjected to a combined mechanical stimulation protocol, consisting of perfusion and cyclic uniaxial compression. Bioreactor cultivation neither affected overall cell viability nor the cell number in collagen hydrogels. Compared with non-loaded controls, mechanical loading promoted the gene expression of COMP and biglycan and induced an up-regulation of matrix metalloproteinase 3. These results circumstantiate that hMSCs are sensitive to mechanical forces, but their differentiation to chondrocytes could not be induced. Further studies are needed to identify the specific metabolic pathways which are altered by mechanical stimulation. Third, for the development of new cell-based therapies for articular cartilage repair, a reliable cell monitoring technique is required to track the cells in vivo non-invasively and repeatedly. This study aimed at analyzing systematically the performance and biological impact of a simple and efficient labeling protocol for hMSCs. Very small superparamagnetic iron oxide particles (VSOPs) were used as magnetic resonance (MR) contrast agent. Iron uptake was confirmed histologically with prussian blue staining and quantified by mass spectrometry. Compared with unlabeled cells, VSOP-labeling did neither influence significantly the viability nor the proliferation potential of hMSCs. Furthermore, iron incorporation did not affect the differentiation capacity of hMSCs. The efficiency of the labeling protocol was assessed with high resolution MR imaging at 11.7 Tesla. VSOP-labeled hMSCs were visualized in a collagen type I hydrogel indicated by distinct hypointense spots in the MR images, resulting from an iron specific loss of signal intensity. This was confirmed by prussian blue staining. In summary, this labeling technique has great potential to visualize hMSCs and track their migration after transplantation for articular cartilage repair with MR imaging. / Gelenkknorpeldefekte stellen immer noch eine der großen Herausforderungen in der Orthopädie und Unfallchirurgie dar. Als zellbasiertes Verfahren ist die Autologe Chondrozytentransplantation (ACT) heute in der klinischen Routine etabliert. Ein großer Nachteil dieser Methode ist jedoch der Verlust des chondrozytären Phänotyps während der Expansion der Zellen. Humane mesenchymale Stammzellen (hMSZ) verfügen über ein ausgeprägtes Proliferationspotential und besitzen die Fähigkeit, unter spezifischen Bedingungen zu Knorpelzellen zu differenzieren. Sie werden daher als alternative Zellen für das Tissue Engineering von funktionellem Knorpelersatzgewebe in Betracht gezogen. In der vorliegenden Arbeit wurden erstens hMSZ in ein Kollagen Typ I Hydrogel eingebracht und zunächst der Grad der chondrogenen Zelldifferenzierung im Konstrukt evaluiert. HMSZ-Kollagenhydrogele zeigten in allen Kultivierungsmedien eine deutliche Kontraktion, welche am stärksten im chondrogenen Differenzierungsmedium unter Zugabe von TGF-ß1 ausgeprägt war. Nach Stimulation mit chondrogenen Faktoren (Dexamethason und TGF-ß1) differenzierten hMSZ zu Knorpelzellen, nachgewiesen durch die Induktion von knorpelspezifischer Genexpression. Die Zellen wiesen eine Chondrozyten-ähnliche Morphologie auf und waren bis auf einen kleinen Bereich in der Mitte des Konstrukts homogen in einer Proteoglykan- und Kollagen Typ II-haltigen extrazellulären Matrix verteilt. Eine chondrogene Differenzierung konnte in der vorliegenden Arbeit jedoch nicht mit jeder hMSZ-Präparation realisiert werden. Durch die Verbesserung der Kulturbedingungen, z.B. durch die Verwendung einer anderen Serumcharge im Gelherstellungsprozess, konnte eine Steigerung der knorpelspezifischen Matrixsynthese erzielt werden. Nichtsdestotrotz spiegeln die großen Schwankungen in der Differenzierungskapazität die hohe Variabilität zwischen verschiedenen Spendern wider, welche die Entwicklung eines knorpelartigen Gewebes beeinflussen. Zusammengefasst zeigen die Ergebnisse, dass das Kollagen Typ I Hydrogel eine geeignete Trägermatrix für hMSZ darstellt, um in Stammzell-basierten Knorpelregenerationstherapien zukünftig als vielversprechende Alternative zur ACT eingesetzt zu werden. Um die Qualität eines in vitro generierten knorpelartigen Gewebes weiter zu verbessern, wird häufig eine mechanische Stimulation in spezifischen Bioreaktorsystemen durchgeführt. In der vorliegenden Arbeit wurden daher zweitens die Effekte von mechanischer Belastung auf die Differenzierung von hMSZ untersucht. HMSZ-Kollagenhydrogele wurden im chondrogenen Differenzierungsmedium ohne TGF-ß1 kultiviert und einem kombinierten mechanischen Stimulationsprotokoll, bestehend aus Perfusion und zyklischer uniaxialer Kompression, ausgesetzt. Die Kultivierung im Bioreaktor hatte weder einen Einfluss auf die Zellvitalität noch auf die Anzahl der Zellen im Kollagen Typ I Hydrogel. Die mechanische Beeinflussung steigerte im Vergleich mit den unbelasteten Kontrollgelen die Genexpression von COMP und Biglykan und führte zu einer Hochregulation von Matrix Metalloproteinase 3. Diese Ergebnisse belegen, dass hMSZ mechanosensitiv sind, jedoch konnte keine Differenzierung zu Knorpelzellen induziert werden. Hierfür sind weitere Studien notwendig, um spezifische Stoffwechselwege zu identifizieren, welche durch die mechanische Stimulation beeinflusst werden. Drittens, für die Entwicklung von neuen zellbasierten Therapien für die Gelenkknorpelrekonstruktion ist eine zuverlässige Bildgebung auf zellulärer Ebene erforderlich, um die Zellen in vivo wiederholt nicht invasiv zu detektieren. Die vorliegende Arbeit hatte zum Ziel, systematisch die Effizienz und die biologischen Auswirkungen einer einfachen und dauerhaften Markierung für hMSZ zu untersuchen. Superparamagnetische Eisenoxidnanopartikel (VSOPs), ein Magnetresonanz (MR)-Kontrastmittel, wurden für die Markierung eingesetzt. Die Aufnahme der Eisenoxidnanopartikel wurde histologisch mittels eisenspezifischer Berliner-Blau-Färbung nachgewiesen und durch Massenspektroskopie quantifiziert. Im Vergleich zu unmarkierten Zellen beeinträchtigte die VSOP-Markierung weder die Vitalität noch das Proliferationspotential der hMSZ. Weiterhin war durch die Aufnahme der Eisenoxidnanopartikel keine Beeinflussung der Differenzierungskapazität der hMSZ zu verzeichnen. Die Effizienz der Zellmarkierung wurde mittels hochauflösender MR-Bildgebung bei 11,7 Tesla beurteilt. VSOP-markierte hMSZ im Kollagen Typ I Hydrogel erschienen als hypointense Punkte in den MR-Bildern, hervorgerufen durch die typische, VSOP-bedingte Signalauslöschung. Histologische Untersuchungen dieser Konstrukte bestätigten die MR-Ergebnisse. Zusammenfassend lässt sich festhalten, dass diese Zellmarkierungsmethode in Verbindung mit der MR-Bildgebung über das Potential verfügt, nach einer Gelenkknorpelrekonstruktion Aufschluss über die Lokalisation und Migration der transplantierten hMSZ zu liefern.
27

New Methods and Applications in Nuclear Magnetic Resonance Microscopy using small RF Coils / Neue Methoden und Anwendungen kleiner HF-Spulen in der NMR-Mikroskopie

Purea, Edmund Armin January 2008 (has links) (PDF)
Nuclear magnetic resonance (NMR) imaging is a well-established imaging technique. If the achieved spatial resolution is below 100 um, it is usually denoted as magnetic resonance microscopy (MRM). The spatial resolution limit is on the order of a few um. As a downside, high resolution imaging is usually time-consuming and technological requirements are very sumptuous. Furthermore, miniaturization of the radiofrequency (RF) coil leading to a so-called microcoil is necessary; it also brings along detrimental effects. Therefore, there is a high potential for optimizing present MRM methods. Hence it is the aim of this work to improve and further develop present methods in MRM with focus on the RF coil and to apply those methods on new biological applications. All experiments were conducted on a Bruker 17.6 T system with a maximum gradient strength of 1 T/m and four RF receiver channels. Minimizing the RF coil dimensions, leads to increased artefacts due to differences in magnetic susceptibility of the coil wire and surrounding air. Susceptibility matching by immersing the coil in FC-43 is the most common approach that fulfills the requirements of most applications. However, hardly any alternatives are known for cases where usage of FC-43 is not feasible due to its specific disadvantages. Two alternative substances (bromotricholoromethane and Fomblin Y25) were presented and their usability was checked by susceptibility determination and demonstration experiments after shimming under practical conditions. In a typical MRM microcoil experiment, the sample volume is significantly smaller than the maximum volume usable for imaging. This mismatch has been optimized in order to increase the experiment efficiency by increasing the number of probe coils and samples used. A four-channel probehead consisting of four individual solenoid coils suited for cellular imaging of Xenopus laevis oocytes was designed, allowing simultaneous acquisition from four samples. All coils were well isolated and allowed quantitative image acquisition with the same spatial resolution as in single coil operation. This method has also been applied in other studies for increased efficiency: using X. laevis oocytes as a single cell model, the effect of chemical fixation on intracellular NMR relaxation times T1 and T2 and on diffusion was studied for the first time. Significant reduction of relaxation times was found in all cell compartments; after reimmersion in buffer, values return close to the initial values, but there were small but statistically significant differences due to residual formaldehyde. Embryos of the same species have been studied morphologically in different developmental stages. Wild type embryos were compared to embryos that had experienced variations in protein levels of chromosomal proteins HMGN and H1A. Significant differences were found between wild type and HMGN-modified embryos, while no difference was observed between wild type and H1-modified embryos. These results were concordant with results obtained from light microscopy and histology. The technique of molecular imaging was also performed on X. laevis embryos. Commercially available antibodies coupled to ultrasmall superparamagnetic iron oxide (USPIO) dextrane coated particles (MACS) served as a specific probe detectable by MRM, the aim being the detection of tissue specific contrast variations. Initially, the relaxivity of MACS was studied and compared to Resovist and VSOP particles. The iron concentration was determined quantitatively by using a general theoretical approach and results were compared to values obtained from mass spectroscopy. After incubation with MACS antibodies, intraembryonal relaxation times were determined in different regions of the embryo. These values allowed determination of local iron oxide particle concentrations, and specific binding could be distinguished from unspecific binding. Although applications in this work were focused on X. laevis oocytes and embryos, 3D-imaging on a beewolf head was also carried out in order to visualize the postpharyngeal gland. Additionally, an isolated beewolf antenna was imaged with a spatial resolution of (8 um)^3 for depiction of the antennal glands by using a microcoil that was specially designed for this sample. The experiments carried out in this work show that commercially available MRM systems can be significantly optimized by using small sample-adapted RF coils and by parallel operation of multiple coils, by which the sample throughput and thus time-efficiency is increased. With this optimized setup, practical use was demonstrated in a number of new biological applications. / Bildgebung mittels magnetischer Kernresonanz (NMR) ist eine etablierte Methode. Liegt die erreichte Ortsauflösung unter 100 um, wird sie allgemein als Magnetresonanz-Mikroskopie (MRM) bezeichnet. Die Untergrenze der Auflösung liegt in der Größenordnung weniger um. Da höchstaufgelöste Bildgebung meist sehr zeitintensiv ist, kostspielige Anforderungen an die zugrunde liegende Technologie setzt und zudem durch die notwendige Verkleinerung der Hochfrequenz (HF)-Spule auf sogenannte microcoils und Erhöhung der Bildauflösung auch nachteilige Effekte zunehmen, besteht viel Optimierungsbedarf bei bestehenden MRM-Methoden. Das Ziel dieser Arbeit war daher die Verbesserung und Weiterentwicklung bestehender Methoden der MRM mit besonderem Augenmerk auf die HF-Spule und ihre Anwendung auf neue biologische Fragestellungen. Alle Experimente wurden an einem Bruker 17.6T System mit einer maximalen Gradientenstärke von 1T/m und vier HF-Empfangskanälen durchgeführt. Die Miniaturisierung der HF-Spule führt zu Bildverzerrungen aufgrund des Unterschieds in magnetischer Suszeptibilität zwischen Luft und Spulendraht. Der übliche Ansatz der Suszeptibilitätsanpassung mit FC-43 ist für die meisten Anwendungen ausreichend, jedoch gibt es kaum bekannte Alternativen für den Fall, dass die Nachteile von FC-43 eine Verwendung verhindern. Es wurden zwei neue Substanzen (Bromtrichlormethan sowie Fomblin Y25) vorgestellt und ihre Verwendbarkeit mittels Suszeptibilitätsmessung und experimentellen Shim-Ergebnissen im praktischen Einsatz geprüft. Bei üblichen MRM-Experimenten mit ’microcoils’ ist das Probenvolumen deutlich kleiner als das maximal für Bildgebung zur Verfügung stehende Volumen. Dieses Ungleichgewicht wurde ausgenutzt, um die Effizienz von Mikroskopie-Experimenten durch parallelen Einsatz mehrerer ’microcoils’ zu erhöhen. Ein Probenkopf mit vier entkoppelten Solenoidspulen wurde für zelluläre Bildgebung an Xenopus laevis (Krallenfrosch)-Oozyten konstruiert. Ohne Auflösungsverlust konnten damit vier Proben zeitgleich quantitativ untersucht werden. Diese Methode wurde auch in weiteren Studien zur Steigerung der Effizienz eingesetzt: Am Modell einzelner Zellen (X. laevis-Oozyten) wurde die Auswirkung chemischer Fixierung auf NMR-Relaxationszeiten (T1, T2) sowie Diffusion erstmals intrazellulär untersucht. Es konnten erhebliche Verkürzungen der Relaxationszeiten in allen Zellkompartimenten festgestellt werden, die nach Spülung mit Pufferlösung bis auf geringe, statistisch signifikante Abweichungen bedingt durch verbleibendes Formaldehyd auf die Ausgangswerte der nichtfixierten Zelle zurückkehrten. In einem weiteren Projekt wurden Embryonen derselben Spezies in verschiedenen Entwicklungsstadien morphologisch untersucht. Wildtyp-Embryonen wurden mit Embryonen verglichen, deren natürlicher Gehalt an chromosomalen Proteinen HMGN und H1A verändert wurden. Signifikante Unterschiede zwischen Wildtyp und HMGN-veränderten Embryonen konnten festgestellt werden, während sich kein Unterschied zu H1A-veränderten Embryonen zeigte. Lichtmikroskopie und Histologie lieferten damit übereinstimmende Ergebnisse. Ebenfalls an Xenopus-Embryonen wurde die Technik der molekularen Bildgebung eingesetzt. Ziel war es, mit kommerziell erhältlichen Antikörpern, die an superparamagnetische Eisenoxidpartikel mit einer Größe von wenigen nm (USPIO) mit Dextranhülle gekoppelt sind (MACS), gewebespezifische Kontraständerungen zu erhalten. Zunächst wurde die Relaxivität von MACS untersucht und mit Resovist- sowie VSOP-Partikeln verglichen. Anschließend wurde die Eisenkonzentration quantitativ unter Zuhilfenahme eines allgemeinen theoretischen Modells bestimmt und mit Ergebnissen verglichen, die massenspektroskopisch gewonnen wurden. Nach Inkubation mit MACS wurden Relaxationszeiten intraembryonal in verschiedenen Regionen gemessen. Daraus wurden Konzentrationen von Eisenoxid-Partikeln berechnet; zusätzlich konnte zwischen spezifischer und unspezifischer Bindung differenziert werden. Obwohl der Anwendungsschwerpunkt dieser Arbeit auf der Bildgebung an X. laevis- Oozyten und Embryonen lag, wurde auch Bildgebung am Kopf eines Bienenwolfs zur 3D-Darstellung der Postpharyngealdrüse durchgeführt. Zusätzlich wurde mit einer speziell auf das Untersuchungsobjekt angepassten ’microcoil’ eine isolierte Bienenwolfantenne mit einer Auflösung von (8 um)^3 untersucht; Ziel war die Darstellung der Antennaldrüsen. Die durchgeführten Projekte zeigen, dass bei kommerziell erhältlichen MRM-Systemen deutliches Optimierungspotential existiert: zum einen durch verkleinerte und probenangepasste HF-Spulen, zum anderen durch die Parallelisierung mehrerer Spulen, wodurch der Probendurchsatz und damit die Zeiteffizienz gesteigert werden kann. Mit diesem optimierten Aufbau konnte anschließend die Nutzbarkeit der MRM bei neuen biologischen Anwendungen gezeigt werden.
28

Suszeptibilitätseffekte in der Kernspinresonanzbildgebung / Susceptibility effects in nuclear magnetic resonance imaging

Ziener, Christian H. January 2008 (has links) (PDF)
Das Dephasierungsverhalten und die daraus resultierende Relaxation der Magnetisierung sind Grundlage aller auf der Kernspinresonanz basierenden bildgebenden Verfahren. Das erhaltene Signalder präzedierenden Protonen wird wesentlich von den Eigenschaften des untersuchten Gewebes bestimmt. Insbesondere die durch magnetisierte Stoffe wie z. B. desoxygeniertes Blut (BOLD-Effekt) oder magnetische Nanopartikel erzeugten Suszeptibilitätssprünge gewinnen zunehmend Bedeutung in der biomedizinischen Bildgebung. In der vorliegenden Arbeit wurden die Einflüsse von Feldinhomogenitäten auf das NMR-Signal untersucht. / The properties of dephasing and the resulting relaxation of the magnetization are the basic principle on which all magnetic resonance imaging methods are based. The signal obtained from the gyrating spins is essentially determined by the properties of the considered tissue. Especially the susceptibility differences caused by magnetized materials (for example, deoxygenated blood, BOLD-effect) or magnetic nanoparticles are becoming more important for biomedical imaging. In the present work, the influence of such field inhomogeneities on the NMR-signal is analyzed.
29

Analytische Näherungsverfahren zur Beschreibung der nuklearen Spin-Dephasierung / Analytical Approaches for the Description of Nuclear Spin Dephasing

Bauer, Wolfgang Rudolf January 2002 (has links) (PDF)
Die Dynamik der Kernspindephasierung in lebenden Systemen enhält relevante Informationen über biologisch wichtige Parameter, wie Sauerstoffversorgung, Mikrozirkulation, Diffusion etc.. Ursächlich für die Dephasierung sind Interaktionen des Spins mit fluktuierenden Magnetfeldern. Notwendig sind also Modelle, welche diese Interaktionen mit den biologisch relevanten Parametern in Beziehung setzen. Problematisch ist, daß fast alle analytische Ansätze nur in extremen Dynamikbereichen der Störfeldfluktuationen (motional narrowing - , static dephasing limit) gültig sind. In dieser Arbeit zeigen wir einen Ansatz, mit dem man die Dynamik der Störfeldfluktuationen erheblich vereinfachen und trotzdem noch deren wesentliche Eigenschaften beibehalten kann. Dieser Ansatz ist nicht auf einen speziellen Dynamikbereich festgelegt. Angewendet wird dieses Näherungsverfahren zur Beschreibung der Spin Dephasierung im Herzmuskel. Die Relaxationszeiten erhält man als Funktion der Kapillardichte und Blutoxygenierung. Vergleiche mit numerisch errechneten Daten anderer, eigenen Messungen am menschlichen Herzen und experimentellen Befunden in der Literatur, bestätigen die theoretischen Vorhersagen. / The dynamics of nuclear spin dephasing in living objects contains relevant information about important parameters as oxygen supply, microcirculation, and diffusion. Spin dephasing is induced by interaction of spins with fluctuating perturbation fields. Desirable are models which relate these interactions to the biological parameters. Unfortunately most analytical approaches are restricted to certain motion regimes, e.g. the motional narrowing or static dephasing limit. In this work we present an analytical approach, which simplifies the perturbation field dynamics but still conserves its relevant properties. This approach is not restricted to any motion regime. As an application we describe spin dephasing in the cardiac muscle. We obtain the relaxation time as a function of capillary density and blood oxygenation. Data are in excellent agreement with numerical simulations of others, own measurements in humans, and experimental data in the literature.
30

Hochfeld 1H-NMR-Mikroskopie zur biophysikalischen Grundlagenforschung / High Field 1H-NMR-Microscopy for Basic Biophysical Research

Haddad, Daniel January 2003 (has links) (PDF)
Dank der mit modernen NMR-Spektrometern (Kernspintomographen) routinemäßig realisierbaren isotropen räumlichen Auflösungen von wenigen Mikrometern, ergeben sich für die 1H NMR-Mikroskopie zahlreiche neue Anwendungsgebiete. Allerdings sind die Möglichkeiten und Grenzen der NMR-Mikroskopie bezüglich ihrer praktischen Anwendbarkeit bisher nur wenig untersucht worden. Die vorliegende Arbeit ist im Bereich der biophysikalischen Grundlagenforschung angesiedelt und soll die praktische Anwendbarkeit der NMR-Mikroskopie auf neuen medizinischen und biologischen Anwendungsgebieten anhand von ausgewählten Beispielen aus diesen Bereichen demonstrieren. Die einzelnen Projekte besitzen deswegen immer auch den Charakter von Machbarkeitsstudien, die aufzeigen sollen, welche Möglichkeiten und Vorteile die NMR-Mikroskopie im Vergleich zu etablierten Untersuchungsmethoden bietet. Im Detail wurden unterschiedliche lebende und fixierte biologische Proben mittels NMR-Mikroskopie zerstörungsfrei und räumlich hochaufgelöst dargestellt. Dabei variierte die spezielle Zielsetzung von der Visualisierung der Invasion eines Tumorsphäroiden in ein Zellaggregat anhand von T2-Parameterkarten (Zeitkonstante der Spin-Spin-Relaxation) über die dreidimensionale Darstellung des Gehirns der Honigbiene in der intakten Kopfkapsel bis hin zur nicht-invassiven Abbildung der Anatomie prenataler Delphine. Für alle durchgeführten Projekte war der nicht-invasive Charakter der NMR-Experimente von entscheidender Bedeutung. Die zu beobachtende Tumorinvasion durfte nicht durch die Messung beeinflusst werden, das Bienengehirn sollte möglichst naturgetreu abgebildet werden, und die untersuchten Delphine sind seltene Museumsstücke, die nicht zerstört werden durften. Die verschiedenen Proben wurden mit der jeweils bestmöglichen räumlichen Auflösung visualisiert, die sich entweder durch das minimal nötige Signal-zu-Rausch-Verhältnis (SNR) oder durch die zur Verfügung stehende Messzeit ergab. Um einzelne feine Strukturen in den Bildern auflösen zu können, mussten sowohl das SNR, als auch das Kontrast-zu-Rausch-Verhältnis optimiert werden. Die Messungen wurden an Hochfeld-NMR-Spektrometern bei 500 und 750 MHz durchgeführt, um das für die hohe Auflösung notwendige SNR zu gewährleisten. Mit den Experimenten konnten zahlreiche Fragen bezüglich mikroskopischer Details der verschiedenen untersuchten Proben nicht-invasiv beantworten werden. Gleichzeitig führten sie zu neuen interessanten Fragestellungen bezüglich der NMR-Mikroskopie an fixierten Proben. Darüber hinaus konnte die praktische Anwendbarkeit der NMR-Mikroskopie als Alternative bzw. Ergänzung zu herkömmlichen Untersuchungsmethoden wie der konfokalen Lasermikroskopie bei der Visualisierung des Bienengehirns und der konventionellen Histologie bei der Untersuchung der Anatomie der prenatalen Delphine demonstriert werden. Durch die Untersuchung der speziellen Vorteile und der Grenzen der Anwendung der NMR-Mikroskopie gegenüber den herkömmlichen Untersuchungsmethoden konnte konkret der praktische Nutzen ihres Einsatzes aufgezeigt und Ergebnisse erzielt werden, die sonst nicht erzielbar wären. Gerade der Einsatz der NMR-Mikroskopie in Form der NMR-Histologie stellt einen vielversprechenden Weg zur Etablierung der NMR-Mikroskopie als Routineuntersuchungsmethode dar. Als ebenso erfolgreich hat sich die Anwendung der NMR-Mikroskopie als Untersuchungsmethode bei der Beobachtung der Tumorinvasion erwiesen, so dass sie auch in der medizinischen in-vitro Forschung und Therapiesimulation als sinnvolle Alternative zu den vorhandenen Methoden angesehen werden kann. Anhand der ausgewählten Anwendungsbeispiele ist es in dieser Arbeit somit gelungen, neue, konkrete Einsatzmöglichkeiten für die NMR-Mikroskopie zu eröffnen und ihre praktische Anwendbarkeit als Untersuchungsmethode für Fragestellungen im Bereich der medizinischen in-vitro Forschung und verschiedener neuro- und entwicklungsbiologischer Bereiche zu demonstrieren. / With modern MR-spectrometers it is possible to achieve isotropic spatial resolutions in the range of only a few microns. Thus, several new fields of application for 1H-MR-Microscopy are being developed. Still, the practical possibilities and limitations of this technique have only been determined rarely. This work has a biophysical background and uses different examples to demonstrate the practical applicability of NMR-Microscopy in the medical and biological sector. Therefore, the different projects are feasibility studies which are used to compare the possibilities and advantages of NMR-Microscopy with other, established examination techniques. In detail, using MR-Microscopy, different living and fixed biological samples have been visualized non-invasively with high spatial resolution. The specific purpose of the studies ranged from the visualization of the invasion of tumor-spheroids into cell aggregates using T2 parameter maps (time constant of the spin-spin relaxation) to the three-dimensional display of the honey bee brain in the intact head capsule and the non-invasive visualization of the anatomy of prenatal dolphins. For all these projects, the non-invasive character of MR-experiments was of utmost importance. The tumor invasion was not to be disturbed by the measurements, the bee brain should be visualized as close to its true natural shape as possible and the examined dolphins represent rare museum specimens which should not be destroyed. The different samples were all imaged with the best possible spatial resolution which was either limited by the necessary signal-to-noise ratio (SNR) or the available scan time. In order to resolve single details and fine structures in the images, it was necessary to optimize the SNR as well as the contrast-to-noise ratio. To guarantee the necessary SNR, the measurements were performed on high field MR-spectrometers with resonance frequencies of 500 and 750 MHz. Numerous questions about microscopic details of the examined samples could be answered non-invasively with the experiments performed. At the same time, the experiments led to new interesting questions about MR-Microscopy on fixed samples. Furthermore, the practical applicability of MR-Microscopy as an alternative or a supplement to conventional examination methods could be demonstrated. Here, these methods were confocal laser microscopy in the case of the honey bee brain and conventional histology in the case of the prenatal dolphins. By investigating the specific advantages and limitations of MR-Microscopy in these cases, it was possible to demonstrate the practical value of its application and to obtain results which would otherwise have been impossible. Especially the use of MR-Microscopy as MR-Histology is a promising application which will help to establish MR-Microscopy as a routine examination method. Since the tumor invasion process could also be observed very successfully using MR-Microscopy, this technique can as well be considered as a valuable tool for medical in-vitro research and therapy simulation and thus an alternative to existing methods. In summary, with the examples chosen in this work, it was possible to find new applications for MR-Microscopy and to demonstrate the practical applicability of this method in the fields of medical in-vitro research as well as neurological and developmental biology.

Page generated in 0.0599 seconds