• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 76
  • 51
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 155
  • 99
  • 85
  • 64
  • 62
  • 62
  • 50
  • 32
  • 18
  • 18
  • 18
  • 16
  • 14
  • 14
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Avaliação da influência da angulação do implante osseointegrado associado à prótese parcial removível classe I mandibular pelo método dos elementos finitos

Santos, Ciandrus Moraes de Freitas [UNESP] January 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2005Bitstream added on 2014-06-13T19:16:56Z : No. of bitstreams: 1 santos_cmf_me_araca.pdf: 1084188 bytes, checksum: 0a96538ac84e5167cd37297d47e91a27 (MD5) / Universidade Estadual Paulista (UNESP) / A resolução protética dos arcos com extremidades livres através da associação entre prótese parcial removível e implantes osseointegrados é, ainda, uma opção pouco utilizada na clínica odontológica. Quando dessa associação, na instalação do implante, por motivos anatômicos ou diversos, o mesmo pode ser instalado com certa angulação. Desse modo, o propósito dessa pesquisa é avaliar, através do método dos elementos finitos bidimensional, a distribuição de tensão e a tendência ao deslocamento nas estruturas de suporte de uma prótese parcial removível de extremidade livre (PPREL), e da própria PPREL, associada a um implante osseointegrado de 10,0 x 3,75 mm (Sistema Bränemark) com diferentes angulações, localizado na distal do rebordo residual, atuando apenas como suporte para a base da prótese. Foram utilizados 6 modelos, os quais, em corte sagital, representam: Modelo A (MA) - hemiarco contendo o dente natural 33 somente e o rebordo alveolar distal; Modelo B (MB) - semelhante ao MA, com um PPREL convencional substituindo os dentes ausentes; Modelo C (MC) - semelhante ao anterior, com um implante verticalizado a 0o na região distal do rebordo, sob a base da prótese; Modelo D (MD) - semelhante ao MC, com o implante angulado a 5º para mesial; Modelo E (ME) - semelhante ao MD, com o implante angulado a 15º para mesial; Modelo F (MF) - semelhante ao ME, com o implante angulado a 30º para mesial. Com o auxílio do programa de elementos finitos ANSYS 8.0, os modelos foram carregados com forças estritamente verticais de 50 N em cada ponta de cúspide. A análise dos Mapas permitiu concluir que: para a maioria das estruturas analisadas, quanto menor o ângulo do implante, menores as tensões observadas nos modelos; O MD (com implante a 5o) foi o que apresentou as melhores combinações de resultados, sendo portanto a melhor opção nas condições estudadas. / The prosthetic resolution of arches with free end saddles by association among removable partial denture and osseointegrated implants, still have a low use in dentistry clinic. This way, the purpose of this study was to evaluate, by the bidimensionsal finite element analysis, the tension distribution and the displacement tendency in the supporting structures of a free end removable partial denture (FERPD), and the own FERPD, associated to an osseointegrated implant of 10,0 x 3,75 mm (Bränemark System), located in the distal area of the free end saddle, acting solely as support for the prosthesis base. Six models in sagital cut were utilized. Such represented: Model A (MA) - hemi arch containing the inferior left canine and the free end saddle; Model B (MB) - similar to MA, with a conventional RPD substituting the absent teeth; Model C (MC) - similar to the previous, with a vertical implant (0o) in the distal of the free end saddle, under the prosthesis base; Model D (MD) - similar to the previous, with the implant in an angulation of 5° to the mesial; Model E (ME) - similar to the previous, with the implant in an angulation of 15°; Model F (MF) - similar to the previous, with the implant angulation of 30°. With the aid of the finite element analysis program ANSYS 8.0, the models were loaded with 50 N of vertical forces on each cuspid of the teeth. The maps analysis allowed conclude that: For the most of analyzed structures, as lower the implant's angle, the lower the observed tension in the models. The MD (implant at 5°) was the better results combination, being the best option in the studied conditions.
122

Avaliação da influência do diâmetro e comprimento do implante osseointegrado associado à PPR Classe I mandibular pelo método dos elementos finitos

Verri, Fellippo Ramos [UNESP] January 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2003Bitstream added on 2014-06-13T20:37:57Z : No. of bitstreams: 1 verri_fr_me_araca.pdf: 6651997 bytes, checksum: 6bb3237d2e73d295c300ea6f6f9c9014 (MD5) / A influência do diâmetro e do comprimento de implantes osseointegrados em associação com próteses parciais removíveis de extremidade livre (PPRELs) ainda não foi relatada na literatura. Dessa forma, este trabalho visou avaliar a esta influência, utilizando o método dos elementos finitos (MEF) bi-dimensional, associando implantes osseointegrados do sistema Branemark sob a base protética de uma PPREL, funcionando apenas como suporte, e analisando mapas de deslocamento e de tensão de von Mises. Para o estudo foram confeccionados oito modelos representativos de uma hemi-arcada mandibular com a presença apenas dos dentes 33 e 34, com as seguintes características: A - sem PPR; B - com PPR sem implante; C - com PPR e implante de 3,75 x 7,00 mm; D - com PPR e implante de 3,75 x 10,00 mm; E - com PPR e implante de 3,75 x 13,00 mm; F - com PPR e implante de 5,00 x 7,00 mm; G - com PPR e implante de 5,00 x 10,00 mm; H - com PPR e implante de 5,00 x 13,00 mm. As forças aplicadas foram estritamente verticais e de 50 N em cada ponta de cúspide. Pelos resultados notou-se que a presença da PPR sobrecarregou o dente suporte, bem como as demais estruturas de suporte da PPR quando comparadas com o modelo A. A presença do implante diminuiu as tensões, principalmente nas extremidades do rebordo desdentado, quando comparados o modelo B com os modelos que possuíam implantes associados. Tanto o comprimento quanto o diâmetro do implante tenderam a diminuir as tensões à medida que aumentavam suas dimensões. Pelos resultados foi possível concluir que: o modelo B foi o que apresentou a maior tendência a deslocamento; quanto maior o comprimento do implante, menores foram os valores do mapa de deslocamento; o modelo B apresentou níveis de tensão de von Mises superiores ao modelo A; os modelos com implantes associados apresentaram níveis menores de tensão de von Mises que o modelo B nas estruturas de suporte da PPR. / The influence of the diameter and length of osseointegrated implants in association with removable partial prostheses of distal-extension (DERPDs) it was not still reported in the literature. In that way, this study evaluated this influence, associating osseointegrated implants of the Branemark system under the prosthetic base of a DERPD, just working as support, and analyzing displacement and von Mises tension maps, using bi-dimensional finite element analysis (FEA). For this study, eight representative models of a lower hemi-arcade were made with the presence of only the teeth 33 and 34, with the following characteristics: A - without RPD; B - with RPD and without implants; C - with RPD and implant of 3,75 x 7,00 mm; D - with RPD and implant of 3,75 x 10,00 mm; E - with RPD and implant of 3,75 x 13,00 mm; F - with RPD and implant of 5,00 x 7,00 mm; G - with RPD and implant of 5,00 x 10,00 mm; H - with RPD and implant of 5,00 x 13,00 mm. The applied forces were strictly vertical and of 50 N in each edge tip. The results shown that the presence of RPD overloaded the support tooth, as well as the other structures of support of RPD when compared with the model A. The presence of the implants reduced the tensions, mainly in the extremities of the toothless edge, when compared model B with the models that possessed implant associated. So much the length as the diameter of the implants tended to reduce the tensions as increased your dimensions. For the results it was possible to conclude that: the model B was what presented the largest tendency to displacement; as larger the length of the it implants, smaller they were the values of the displacement map; the model B presented levels of von Mises tension superiors to the model A; the models with implant associated presented smaller levels of von Mises tension that the model B in the structures of support of RPD; the increase of the length and of the diameter of the implants.
123

Influência dos sistemas de retenção e da inclinação do rebordo residual em casos de próteses conjugadas Classe I mandibular: análise da distribuição das tensões pelo método da fotoelasticidade

Ferraço, Renato [UNESP] 24 April 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-04-24Bitstream added on 2014-06-13T19:37:37Z : No. of bitstreams: 1 ferraco_r_me_araca.pdf: 1898873 bytes, checksum: a4b549caf699d7868a711624716d6212 (MD5) / A reabilitação de pacientes classe I de Kennedy mandibular através de Prótese Parcial Removível é de difícil resolução devido a diferença de resiliência existente entre o ligamento periodontal dos dentes suportes e a mucosa do rebordo residual. A inclinação do rebordo residual no sentido sagital pode influenciar na distribuição das tensões transmitidas pela incidência de cargas em próteses parciais removíveis de extremidade livre associadas a próteses parciais fixas. Na associação da prótese parcial removível com próteses parciais fixas, o profissional tem como alternativa aos grampos tradicionais, o uso de encaixes extra-coronários que podem melhorar a estética e o funcionamento biomecânico do conjunto. Desse modo, o objetivo desse estudo foi avaliar a característica da distribuição de tensões em próteses parciais removíveis mandibulares de extremidade livre associadas a próteses parciais fixas nos dentes suporte com diferentes sistemas de retenção: (1) grampo por ação de pontas; (2) sistema ASC-52; (3) sistema ERA; e (4) encaixe de semi-precisão Score-PD, pela metodologia da fotoelasticidade. E, analisar a distribuição de tensões em próteses parciais removíveis mandibulares de extremidade livre associadas a próteses parciais fixas nos dentes suporte com diferentes sistemas de retenção: (1) grampo por ação de pontas e (2) sistema ERA, variando duas inclinações de rebordo residual: (1) horizontal e (2) descendente distal. Cargas axiais de 100N foram aplicadas sobre os dentes das próteses parciais removíveis. As imagens das aplicações foram capturadas e a distribuição das tensões foi avaliada, pela formação das franjas fotoelásticas. No primeiro estudo, a prótese com encaixes de semi-precisão produziu os maiores níveis de tensão na região de ápice, entre as raízes dos últimos dentes suporte e na porção mais distal do rebordo... / The rehabilitation of patients mandibular class I of Kennedy through Removable Partial Denture is difficult to solve because the difference in strength between the periodontal ligament of the abutment teeth and the residual ridge mucosa. The inclination of the residual ridge towards sagital may influence the distribution of stresses transmitted by the incidence of loads in distal extension removable partial dentures associated with fixed partial dentures. In association removable partial denture – fixed partial dentures, the professional has as alternative to the traditional clasps, the use of extra-coronary attachments that can improve the aesthetics and the biomechanics. Therefore, the objective of this study was to evaluate the characteristic distribution of tensions in mandibular distal extension removable partial dentures (1) “I” bar clasps, (2) ASC-52system, (3) ERA system, and (4) semi-precision Score-PD system, by the methodology of photoelasticity. And, analyze the distribution of tensions in mandibular distal extension removable partial dentures associated to the fixed partial dentures in the abutment teeth with different retention systems: (1) “I” bar clasps and (2) ERA system, ranging from two inclinations residual ridge: (1) horizontal and (2) distal descending. Axial loads of 100N were applied on the teeth of removable partial dentures. The images of the applications were captured and distribution of stress was assessed by the formation of the photoelastic fringes. In the first study, the prosthesis with semi-precision attachment produced the highest levels of tension in the region of apex, between the roots of the abutment teeth and in the more distal portion of the residual ridge. The prostheses with resilient attachments showed the largest fringes formations in the cervical-distal of the last abutment tooth. In the second study, horizontal ridge presented... (Complete abstract click electronic access below)
124

Falhas e complica??es com o uso de pr?tese parcial remov?vel inferior de extremidade livre bilateral

T?rres, Ana Clara Soares Paiva 11 March 2014 (has links)
Made available in DSpace on 2014-12-17T15:43:56Z (GMT). No. of bitstreams: 1 AnaCSPT_DISSERT.pdf: 2140417 bytes, checksum: 8ecf2918cdf8a508e2b68c89eeb3e3ea (MD5) Previous issue date: 2014-03-11 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / Aim: To determine the frequency and type of complications related to removable partial denture (RPD) less, Kennedy Class I, over time . Materials and Methods: This observational study consisted of a sample of 65 users PPR lower arches in Kennedy Class I and dentures, rehabilitated in the Department of Dentistry, Federal University of Rio Grande do Norte (UFRN). Patients were followed through periodic controls during periods of 60 days, 6 months and 1 year from installation. After the first year of control had other returns annually. The occurrence of complications or prosthetic failure was observed and recorded in a specific clinical record over 39 months. The patterns of failures observed were classified in the following situations: occurrence of traumatic ulcers after 2 months of installation, lack of retention, fracture or caries in the rest, fracture or dislocation of the artificial teeth, the larger connector fracture, fracture clip fracture support, poor support (need to reline the denture) and prosthesis fracture. Results: The incidence of complications was low frequency, being higher in the second year of use of the prosthesis. Among the complications that occurred more is the loss of retention (31.57%). Failures more severe and difficult to solve as the fracture elements of the metal structure of the PPR had low occurrence and were represented by only one case of the larger connector (5.3%) fractures. Conclusion: Removable partial dentures mandibular free end opposing of the conventional dentures have a low complication rate after 39 months of use when subjected to periodic controls / Objetivo: Verificar a frequ?ncia e tipo de complica??es relacionadas ? pr?tese parcial remov?vel (PPR) inferior, classe I de Kennedy, ao longo do tempo. Materiais e M?todos: Este estudo observacional foi composto por uma amostra de 65 usu?rios de PPR inferior em arcos Classe I de Kennedy e pr?tese total superior, reabilitados no Departamento de Odontologia da Universidade Federal do Rio Grande do Norte (UFRN). Os pacientes foram acompanhados por meio de controles peri?dicos nos per?odos de 60 dias, 6 meses e 1 ano desde a instala??o. Ap?s o primeiro ano de controle os demais retornos tiveram periodicidade anual. A ocorr?ncia de complica??es ou falhas prot?ticas foi observada e registrada em ficha cl?nica espec?fica ao longo de 39 meses. Os padr?es de falhas observados foram enquadrados nas seguintes situa??es: ocorr?ncia de ?lceras traum?ticas depois de 2 meses de instala??o, aus?ncia de reten??o, fratura de nicho ou c?rie sob o nicho, fratura ou descolamento dos dentes artificiais, fratura do conector maior, fratura de grampo, fratura do apoio, suporte deficiente (necessidade de reembasamento da pr?tese) e fratura da pr?tese. Resultados: A ocorr?ncia de complica??es apresentou baixa frequ?ncia, sendo maior a partir do segundo ano de uso da pr?tese. Dentre as complica??es que mais aconteceram est? a perda de reten??o (31,57%). Falhas de maior gravidade e de dif?cil resolu??o como a fratura de elementos da estrutura met?lica da PPR tiveram baixa ocorr?ncia e foram representadas por apenas um caso de fratura do conector maior (5,3%). Conclus?o: Pr?teses parciais remov?veis de extremidade livre mandibulares opostas a pr?teses totais convencionais apresentam baixo ?ndice de complica??es ap?s 39 meses de uso quando submetidas a controles peri?dicos
125

Výjimečné množiny v matematické analýze / Exceptional Sets in Mathematical Analysis

Rmoutil, Martin January 2014 (has links)
Title: Exceptional Sets in Mathematical Analysis Author: Martin Rmoutil Department: Department of Mathematical Analysis Supervisor: Doc. RNDr. Ondřej Kalenda, Ph.D., DSc., Department of Mathematical Analysis Abstract: The present thesis consists of four research articles. In the first paper we study the notion of σ-lower porous set; our main result is the existence of two closed sets A, B ⊂ R which are not σ-lower porous, but their product in R2 is lower porous. In the second and third article we use a set-theoretical method of el- ementary submodels involving the Lwenheim-Skolem theorem to prove that certain σ-ideals of sets in Banach spaces are separably determined. In the second article we do so for σ-porous sets and σ-lower porous sets. In the next article we refine these methods obtaining separable determination of a wide class of σ-ideals. In both cases we derive interesting corollaries which extend known theorems in separable spaces to the nonseparable setting; for example, we obtain the following theorem. Any continuous convex function on an Asplund space is Frchet differentiable outside a cone small set. In the fourth article we introduce the following notion. A closed set A ⊂ Rd is said to be c-removable if the following is true: Every real function on Rd is convex whenever it is continuous on Rd...
126

Avaliação da influência da angulação do implante osseointegrado associado à prótese parcial removível classe I mandibular pelo método dos elementos finitos /

Santos, Ciandrus Moraes de Freitas. January 2005 (has links)
Orientador: Eduardo Piza Pellizzer / Banca: Eduardo Passos Rocha / Banca: Alcides Gonini Júnior / Resumo: A resolução protética dos arcos com extremidades livres através da associação entre prótese parcial removível e implantes osseointegrados é, ainda, uma opção pouco utilizada na clínica odontológica. Quando dessa associação, na instalação do implante, por motivos anatômicos ou diversos, o mesmo pode ser instalado com certa angulação. Desse modo, o propósito dessa pesquisa é avaliar, através do método dos elementos finitos bidimensional, a distribuição de tensão e a tendência ao deslocamento nas estruturas de suporte de uma prótese parcial removível de extremidade livre (PPREL), e da própria PPREL, associada a um implante osseointegrado de 10,0 x 3,75 mm (Sistema Bränemark) com diferentes angulações, localizado na distal do rebordo residual, atuando apenas como suporte para a base da prótese. Foram utilizados 6 modelos, os quais, em corte sagital, representam: Modelo A (MA) - hemiarco contendo o dente natural 33 somente e o rebordo alveolar distal; Modelo B (MB) - semelhante ao MA, com um PPREL convencional substituindo os dentes ausentes; Modelo C (MC) - semelhante ao anterior, com um implante verticalizado a 0o na região distal do rebordo, sob a base da prótese; Modelo D (MD) - semelhante ao MC, com o implante angulado a 5º para mesial; Modelo E (ME) - semelhante ao MD, com o implante angulado a 15º para mesial; Modelo F (MF) - semelhante ao ME, com o implante angulado a 30º para mesial. Com o auxílio do programa de elementos finitos ANSYS 8.0, os modelos foram carregados com forças estritamente verticais de 50 N em cada ponta de cúspide. A análise dos Mapas permitiu concluir que: para a maioria das estruturas analisadas, quanto menor o ângulo do implante, menores as tensões observadas nos modelos; O MD (com implante a 5o) foi o que apresentou as melhores combinações de resultados, sendo portanto a melhor opção nas condições estudadas. / Abstract: The prosthetic resolution of arches with free end saddles by association among removable partial denture and osseointegrated implants, still have a low use in dentistry clinic. This way, the purpose of this study was to evaluate, by the bidimensionsal finite element analysis, the tension distribution and the displacement tendency in the supporting structures of a free end removable partial denture (FERPD), and the own FERPD, associated to an osseointegrated implant of 10,0 x 3,75 mm (Bränemark System), located in the distal area of the free end saddle, acting solely as support for the prosthesis base. Six models in sagital cut were utilized. Such represented: Model A (MA) - hemi arch containing the inferior left canine and the free end saddle; Model B (MB) - similar to MA, with a conventional RPD substituting the absent teeth; Model C (MC) - similar to the previous, with a vertical implant (0o) in the distal of the free end saddle, under the prosthesis base; Model D (MD) - similar to the previous, with the implant in an angulation of 5° to the mesial; Model E (ME) - similar to the previous, with the implant in an angulation of 15°; Model F (MF) - similar to the previous, with the implant angulation of 30°. With the aid of the finite element analysis program ANSYS 8.0, the models were loaded with 50 N of vertical forces on each cuspid of the teeth. The maps analysis allowed conclude that: For the most of analyzed structures, as lower the implant's angle, the lower the observed tension in the models. The MD (implant at 5°) was the better results combination, being the best option in the studied conditions. / Mestre
127

Avaliação do nível de inserção óssea do dente suporte em prótese parcial removível mandibular classe I associada a implante osseointegrado: análise pelo método dos elementos finitos

Verri, Fellippo Ramos [UNESP] 11 December 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-12-11Bitstream added on 2014-06-13T19:44:51Z : No. of bitstreams: 1 verri_fr_dr_araca.pdf: 1853726 bytes, checksum: 578403c1602d78c980bb821e076ea43c (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A colocação de PPR de extremidade livre no arco inferior é uma das mais complexas dentro da área protética. A associação desta com implantes na região distal tem melhorado biomecanicamente seu funcionamento. Porém, existem poucos estudos a respeito desta associação levando em consideração o nível de inserção óssea do dente suporte. Assim, o objetivo desta pesquisa foi avaliar, por meio do método dos elementos finitos bidimensional, a distribuição de tensão nas estruturas de suporte de uma PPREL, associada a um implante osseointegrado de 10,0 x 3,75 mm (Sistema Branemark), próximo ao dente suporte, com diferentes níveis de inserção óssea (íntegro e 1/2 da raiz) e com diferentes tipos de conexão entre a PPR e o dente suporte (apoio incisal e placa distal). Para o estudo, foram confeccionados 8 modelos mandibulares, de extremo livre, com a presença apenas do dente 33, sendo: MA - PPREL convencional, apoio incisal distal, inserção íntegra; MB - idem ao MA, mas utilizando placa distal; MC - idem ao MA, com implante de 3,75 x 10,0 mm e sistema ERA associado; MD - idem ao MC, mas utilizando placa distal; ME - idem ao MA, mas com perda de inserção de 1/2 da raiz; MF - idem ao MB, mas com perda de inserção de 1/2 da raiz; MG - idem ao MC, mas com perda de inserção de 1/2 da raiz; MH - idem ao MD, mas com perda de inserção de 1/2 da raiz. Com o auxilio do programa ANSYS 9.0, os modelos foram carregados com forças verticais de 50 N em cada ponta de cúspide. Os resultados foram obtidos pelos mapas de deslocamento e de tensão de von Mises e mostraram que o implante favorece a associação da forma descrita, que a placa possibilita um maior alívio e menor deslocamento do dente suporte, e que a perda do periodonto de suporte prejudica o prognóstico da prótese. / The rehabilitation with distal extension RPDA is very complex in the prosthetic area and the association with implants had improving its work biomechanical. However, there is little studies about this type of association and no study about the lost of insertion was encountered by FEA. So, the aim of this study was to evaluate, by FEA 2-D, the tension distribution in support structures of a DERPD associated with a osseointegrated implant of 10,0 x 3,75 mm (Branemark System), near to support tooth, with different levels of bone insertion (no lost and 1/2 of root) and with different type of connection between the DERPD and de support tooth (incisal rest and distal plate). For the study, 8 distal extension mandibular models were made, with the presence of tooth 33, presenting: MA - conventional DERPD, incisal rest, no bone lost; MB - like MA, but with distal plate; MC - like MA, but with implanto of 3,75 x 10,0 mm and ERA system associated; MD - like MC, but with distal plate; ME - like MA, but with bone lost of 1/2 of root; MF - like MB, but with bone lost of 1/2 of root; MG - like MC, but with bone lost of 1/2 of root; MH - like MD, but with bone lost of 1/2 of root. By mean of program of FEA ANSYS 9.0, the models were carried with axial forces of 50 N in each cusp tip. The results were obtained by dislodgement maps and von Mises tension maps and shown that the implant was benefit to association by the study, and the plate decreased the tension and the dislodgement of the support tooth, and the bone lost was prejudicial to prognostic of this type of prosthesis. By this methodology, was possible to conclude that: the introduction of an osseointegrated implant with ERA system used like this study decrease the dislodgement of above structures in all models.
128

Influência do formato do rebordo na associação de uma prótese parcial removível de extremidade livre mandibular associada ao implante com sistema de retenção ERA, pelo método dos elementos finitos

Lucas, Liliana Vicente Melo de [UNESP] 18 December 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-12-18Bitstream added on 2014-06-13T20:06:14Z : No. of bitstreams: 1 lucas_lvm_dr_araca.pdf: 2722998 bytes, checksum: 4598b84f7bad6e641b9c428ccef728d3 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Associação das próteses parciais removíveis de extremidade livre com os implantes osseointegrados é, ainda, uma opção de tratamento pouco explorada na Odontologia reabilitadora moderna. Por isso, o objetivo deste estudo é avaliar, utilizando o método dos elementos finitos bidimensional, a distribuição de tensão e o deslocamento nas estruturas de suporte da prótese parcial removível de extremidade livre (PPREL) associada a um implante osseointegrado de 10,0 x 3,75 mm com sistema ERA de retenção, em diferentes formatos de rebordo alveolar. Para tanto, foram criados oito modelos, os quais, em corte sagital, representam: Modelo A (MA) - uma hemiarcada com rebordo horizontal, sem suporte posterior, com a presença do dente 33 e de uma PPREL convencional, com apoio metálico na incisal do dente 33, em substituição aos dentes 34, 35, 36 e 37; Modelo B (MB) - semelhante ao MA, diferenciando-se deste pela presença de um implante de 3,75 x 10,00 mm com sistema ERA de retenção associado, na região posterior da base da PPREL; Modelo C (MC) - semelhante ao MA, entretanto o rebordo distal apresenta uma conformação ascendente distal; Modelo D (MD) - semelhante ao MC, diferenciando-se deste pela presença do implante com sistema de retenção associado; Modelo E (ME) - semelhante ao MA, entretanto o rebordo distal apresenta uma conformação descendente distal; Modelo F (MF) - semelhante ao ME, diferenciando-se deste pela presença do implante com sistema ERA de retenção; Modelo G (MG) - semelhante ao MA, entretanto o rebordo distal apresenta formato descendente-ascendente; Modelo H (MH) - semelhante ao MG, diferenciando-se deste pela presença do implante com sistema ERA de retenção. Com o auxílio do programa de elementos finitos ANSYS 9.0, os modelos foram carregados com forças verticais de 50 N, em cada ponta de cúspide.... / The association of mandibular distal extension removable artial dentures with an osteointegrated implant is a treatmeat hasn't been fully explored by modern rehabilitation dentistry yet. For this reason, the objective of this study is to evaluate, by means of the bidimensional method of finite elements, the distribution of tension and the displacement on the structures supporting the distal extension removable partial denture (DERPD), associated to a 10.0 x 3.75 mm osteointegrated implant with an ERA retention system, in alveolar ridges of different shapes. For that purpose, eight models were created, representing, from a sagittal perspective: Model A (MA) - a half arch with a horizontal ridge without posterior support, with the presence of the lower left canine, and a conventional DERPD, with metallic support in the incisal aspect of this canine, as replacement for the first and second pre-molars and the first and second molars of the lower left half arch; Model B (MB) - similar to MA, but different because of the presence of a 3.75 x 10.00 mm implant with an associated ERA retention system in the posterior region of the DERPD base; Model C (MC) - similar to MA, however with a distally ascending ridge format; Model D (MD) - similar to MC, but different because there is an implant associated to a retention system; Model E (ME) - similar to MA, however with a distally descending ridge format; Model F (MF) - similar to ME, but different in the sense that there is an implant with an associated ERA retention system; Model G (MG) - similar to MA, however with a distally descending-ascending ridge format; Model H (MH) - similar to MG, but different in the sense that there is an implant with an associated ERA retention system. The finite element program ANSYS 9.0 was used to load the models with vertical forces of 50 N, on each cuspid tip...(Complete abstract, click electronic address below)
129

Avalia??o da desadapta??o das selas de pr?teses parciais remov?veis ap?s 1 a 5 anos de uso

Aquino, Luana Maria Martins de 03 February 2009 (has links)
Made available in DSpace on 2014-12-17T15:30:52Z (GMT). No. of bitstreams: 1 LuanaMMA.pdf: 2018250 bytes, checksum: 40d3a2d59df5edbadcdae3ffaf599eb2 (MD5) Previous issue date: 2009-02-03 / The non-adaptation of the removable partial prosthesis (RPP) base to fibromucosal tissue is caused by resorption of residual ridges (RRR). The onset of bone resorption, which occurs after tooth extraction and continues throughout life, is accelerated by local or systemic factors. Aim: Assess the degree of non-adaptation of removable partial prosthesis saddles and the factors that influence it. Methodology: A sectional study was conducted with 81 patients using RPP who had their prostheses installed between 2003 and 2007 (1 to 5 years of use) at the Faculty of Dentistry of the Universidade Federal do Rio Grande do Norte (UFRN). After anamnese and clinical examination, a cast was made with polyether-based material, using the base of the prosthesis to make the impression. The base of the saddle was loaded with the casting material and positioned in the mouth, applying pressure on the supports. After polymerization, the material was removed from the saddle and measurements were taken at 3 different points using a pachymeter. Results: The non-adaptation of the saddle increased significantly with years of use (p = 0.005). The tooth-tissue supported prostheses obtained higher mean non-adaptation values than those of tooth supported prostheses (p < 0.001). Flaccid mucosa showed the worst non-adaptation results, which were statistically different from resilient mucosa (p < 0.001). The greater the extension of the saddle, the greater the non-adaptation (p < 0.001). The natural tooth antagonistic arch yielded better results than did RPP and total prosthesis (p < 0.001). Saddle non-adaptation at the free end was less near the pillar tooth and greater in the more posterior region (p < 0.001). When adaptation of the supports to the niches was poor, greater saddle non-adaptation occurred than when it was good or fair (p < 0.001). Saddles located in the posterior region of the arch had greater non-adaptation than those in the anterior region (p = 0.023). Conclusion: The mean non-adaptation of the saddle to the residual ridges was 0.27 mm. It can be concluded that, even with the use of RPP, bone height reduction was slight within the 1-5-year period of use. The following are factors that influence adaptation of the RPP saddle base: years of use, age, force transmission path to the alveolar bone, location of the toothless area, antagonistic arch, type of mucosa, adaptation of supports to the niche and extension of the saddle / A desadapta??o da base das pr?teses parciais remov?veis (PPR) com o tecido fibromucoso ? causada pela reabsor??o dos rebordos residuais (RRR). A reabsor??o ?ssea inicia logo ap?s a exodontia de um elemento dent?rio e continua por toda a vida, sendo acelerada por fatores locais ou sist?micos. Objetivo: Avaliar o grau de desadapta??o das selas de pr?teses parciais remov?veis e os fatores que a influenciam. Metodologia: Foi realizado um estudo seccional com 81 pacientes usu?rios de PPR que instalaram suas pr?teses no per?odo de 2003 a 2007 (1 a 5 anos de uso) no Departamento de Odontologia da UFRN. Ap?s a anamnese e do exame f?sico, foi realizada uma moldagem com material a base de poli?ter, utilizando a base da pr?tese como moldeira, para copiar o espa?o existente entre a base da sela e o rebordo residual. A base da sela foi carregada com o material de moldagem e levada em posi??o na boca, fazendo-se press?o sobre os apoios. Ap?s a polimeriza??o, removeu-se o material de moldagem da sela e realizou-se a medi??o da espessura do molde com o aux?lio de um paqu?metro manual. Resultados: A desadapta??o da sela aumentou significativamente a medida que aumentavam os anos de uso (p=0,005). Indiv?duos com 50 anos ou mais, apresentaram maior desadapta??o do que indiv?duos mais jovens (p<0,001). As pr?teses dentomucossuportadas obtiveram maiores m?dias de desadapta??o do que as dentossuportadas (p<0,001). O tipo de mucosa fl?cida apresentou piores resultados de adapta??o sendo estatisticamente diferente da mucosa resiliente (p<0,001). Quanto maior a extens?o da sela, maior a desadapta??o (p<0,001). O arco antagonista dente natural apresentou melhores resultados em rela??o a PPR e pr?tese total (p<0,001). A desadapta??o da sela em extremidade livre foi menor pr?ximo ao dente pilar e maior na regi?o mais posterior da sela (p<0,001). A adapta??o dos apoios aos nichos quando se encontrava ruim obteve maior desadapta??o da sela comparadas as adapta??es do tipo boa e regular (p<0,001). Selas localizadas em regi?o posterior do arco obtiveram maiores desadapta??o que as selas em regi?o anterior (p=0,023). Conclus?o: A m?dia de desadapta??o da sela sobre os rebordos residuais foi de 0,27mm, podendo-se concluir que, mesmo com o uso da PPR, a redu??o da altura ?ssea foi pequena dentro do per?odo de 1 a 5 anos de uso. S?o fatores que influenciam na adapta??o da base da sela de PPR: tempo de uso da pr?tese, idade, via de transmiss?o de for?a para o osso alveolar, local da ?rea desdentada, arco antagonista, tipo de mucosa, adapta??o dos apoios nos nichos e extens?o da sela
130

Avalia??o cl?nica longitudinal do periodonto de dentes pilares e n?o pilares de pr?teses parciais remov?veis

Amaral, Bruna Aguiar do 27 February 2007 (has links)
Made available in DSpace on 2014-12-17T15:31:01Z (GMT). No. of bitstreams: 1 BrunaAA.pdf: 501159 bytes, checksum: 30bc6bac9bef1fd1e36f669902ea0e7c (MD5) Previous issue date: 2007-02-27 / The literature has shown a relation between periodontics and the removable partial denture (RPD), with progressive destruction observed in the support structures. The aim of this study was to clinically assess periodontal condition in users of removal partial denture (RPD), and compare right abutments teeth, indirect abutments and controls before installation and after 1 year, in addition to comparing tooth-supported and tooth mucosa-supported abutments. A total of 50 patients, 32 women and 18 men, mean age of 45 years, took part in the study. The patients were examined by a single examiner at prosthesis installation and after 3, 6, 9 and 12 months. The following were verified at each examination: Probe Depth (PD), Plaque Index (PI), Gingival Index (GI), the amount of Keratinized Mucosa (KM), Gingival Recession (GR) and Dental Mobility (DM); in addition patients received oral hygiene orientation, accompanied by prophylaxis, periodontal scaling and root planing (PSRP), when necessary. Analysis of Variance (ANOVA) with Tukey-Kramer post test was used to assess the dependent variables (PD, PI, KM, GR) of the three groups over time while Friedman s test was used for GI. To assess the outcomes of prosthesis type in the right abutment group, a confidence interval-based analysis was performed. The results showed that the control group was the least compromised in all the variables studied. With respect to development of the groups over time, it was verified that the measures for GR, PD, GI and KM increased from initial examination to 1 year of use in all the groups, but only PI showed a significant increase. There was a non-discriminatory low prevalence of dental mobility. The tooth mucosa-supported prosthesis had significantly higher values for GR, GI and PI and significantly lower ones for KM when compared to tooth-supported. Over time, both types of prostheses showed no significant differences from initial to final examination for the variables GR, PD, KM and GI, with PI significant only for tooth-supported. The results showed that the teeth most involved in RPD design had greater potential of periodontal damage, probably because of greater dental biofilm accumulation. Abutments elements adjacent to the free extremities had less favorable periodontal condition than those adjacent to interpolated spaces, but the use of RPD did not worsen the initial condition / A literatura tem mostrado uma rela??o entre a periodontia e a pr?tese parcial remov?vel (PPR), observando-se destrui??es progressivas das estruturas de suporte. O prop?sito do presente trabalho ? avaliar clinicamente a condi??o periodontal em usu?rios de pr?tese parcial remov?vel (PPR), comparando os dentes pilares diretos, pilares indiretos e os dentes n?o envolvidos no desenho da pr?tese, antes da instala??o e ap?s 1 ano de uso. E ainda comparar os pilares diretos de PPR dento-suportada e dento-muco-suportada. Um total de 50 pacientes, 32 do sexo feminino e 18 do masculino, com idade m?dia de 45 anos participaram da pesquisa. Os pacientes foram examinados no momento da instala??o da pr?tese e ap?s 3, 6, 9 e 12 meses, por um ?nico examinador. Em cada exame foram verificados: a recess?o gengival (RG) profundidade de sondagem (PS), o ?ndice de placa (IP), o ?ndice gengival (IG), a quantidade de mucosa ceratinizada (MC), e a mobilidade dent?ria (MB), al?m da orienta??o de higiene oral, acompanhada de profilaxia e raspagem e alisamento corono - radicular (RACR) quando necess?ria. Para avaliar o comportamento das vari?veis dependentes (RG, PS, IP, MC) dos tr?s grupos ao longo do tempo, o teste de escolha foi a an?lise de vari?ncia de tend?ncia linear com o p?s teste de Tukey-Kramer, e para a vari?vel IG foi realizado o teste de Friedman. Para avaliar os desfechos com rela??o ao tipo de pr?tese no grupo pilar direto, foi feita an?lise a partir do intervalo de confian?a. Os resultados mostraram que o grupo controle foi o que apresentou menor comprometimento em todas as vari?veis estudadas. Com rela??o ao desenvolvimento dos grupos no decorrer do tempo, verificou-se que as m?dias da RG, PS, IG e MC aumentaram do exame inicial para 1 ano de uso, em todos os grupos, mas somente o IP mostrou aumento significativo. A mobilidade dent?ria foi pouco discriminat?ria por apresentar baixa preval?ncia. No que diz respeito ? diferen?a entre as pr?teses, a pr?tese dento-muco-suportada mostrou valores significativamente superiores de RG, IG e IP e significativamente inferiores MC em rela??o ? dento-suportada. Ao longo do tempo, os dois tipos de pr?tese n?o apresentaram diferen?as significativas do exame inicial para o final para as vari?veis: RG, PS, MC e IG, j? IP foi significativo somente na pr?tese dento-suportada. Os resultados obtidos mostraram que os dentes mais envolvidos no desenho da PPR apresentaram maior potencial de destrui??o periodontal, provavelmente por apresentarem maior ac?mulo de biofilme dent?rio. Elementos pilares adjacentes a extremidades livres apresentaram condi??o periodontal menos favor?vel do que os pilares adjacentes a espa?os intercalados, por?m o uso de PPR n?o agravou a condi??o inicial

Page generated in 0.2226 seconds