• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 76
  • 51
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 155
  • 99
  • 85
  • 64
  • 62
  • 62
  • 50
  • 32
  • 18
  • 18
  • 18
  • 16
  • 14
  • 14
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Avaliação in vitro da precisão de três técnicas para moldagem do arco superior parcialmente edentado / Evaluation in vitro of the accuracy of three impression techniques for the partially edentulous upper arch

Eliseu Antonio Bueno Junior 29 September 2005 (has links)
Este estudo serviu ao objetivo de avaliar a capacidade de reprodução da região do palato e o posicionamento de pilares em modelos de gesso de um arco superior parcialmente edentado, obtidos a partir de três técnicas de moldagem: 1) alginato em moldeira de estoque - AL; 2) pasta zincoeugenólica em moldeira individual, seguida de sobremoldagem com alginato em moldeira de estoque - MS e 3) silicone de condensação em moldeira de estoque pela técnica da dupla moldagem ou do reembasamento - SC. Os modelos de gesso testados foram obtidos a partir de moldagens executadas sobre modelo padrão metálico. Pontos representativos do perfil palatino, a distância relativa entre os pilares, bem como suas inclinações, foram mensurados com um aparelho de medição tridimensional de coordenadas e analisados quanto à sua fidedignidade em relação à morfologia do modelo padrão. Os resultados demonstraram que: 1) ocorreram distorções verticais positivas e negativas nos modelos produzidos pelas três técnicas, sendo que a técnica SC apresentou as maiores variações, predominantemente negativas, produzindo modelos com palato mais profundo quando comparados àqueles obtidos pelas técnicas M e A; 2) foram observadas distorções horizontais positivas e negativas nos modelos produzidos pelas três técnicas, com tendência de aumento das distâncias inter-pilares para as técnicas AL e SC e de encurtamento para a técnica MS; 3) os desvios angulares foram inexpressivos no comprometimento da inclinação axial dos pilares quando considerada a estabilização da estrutura metálica de uma prótese removível; 4) as distorções verificadas com as três técnicas estudadas estão dentro dos parâmetros de aceitabilidade clínica estabelecidos neste trabalho. / The objective of this study was to evaluate the reproduction potential of the palate area and the position of abutments in partially edentulous, upper stone casts produced with three impressions techniques: 1) irreversible hydrocolloid in stock tray - AL; 2) zinc oxide-eugenol paste in a custom tray with a pick-up impression of irreversible hydrocolloid - MS and 3) putty-wash condensation silicone in stock tray - SC. Representative points on the palatal surface and the relative distance between the abutments as well their inclination were measured with a three-dimensional coordinate measurement equipment and the data used to analyze the fidelity of the casts in relation to the original metal model. The results showed: 1) positive and negative vertical discrepancies on casts made from all impression techniques, with SC responsible for the highest variations (predominantly negatives) that rendered casts with a deeper palatal vault when compared to those obtained with AL and MS; 2) positive and negative horizontal discrepancies on casts produced from all impression techniques, with AL and SC tending to increase the distances between supports while MS seemed to decrease these distances; 3) the angular deviations observed represented no substantial compromise to the axial inclination of the abutment when considering the stability of the removable prosthesis framework; 4) the discrepancies evidenced with the three techniques were within the benchmark values for clinical acceptability initially established.
82

"Avaliação da força de tração da sela modificada para prótese" / Evaluation of traction force in modified saddle for prosthesis.

Edna Goncalves da Costa 11 August 2005 (has links)
Do planejamento à execução da prótese mucosa-dento-suportada, a literatura apresenta trabalhos que aponta m as dificuldades do desempenho de uma prótese que se relaciona com tecidos de comportamentos distintos, dente e fibromucosa. Estes trabalhos abordam os problemas biomecânicos e os prejuízos que sofrem o osso e os dentes, sob pressão, durante a mastigação, bem como as dificuldades de distribuição das cargas sobre os tecidos bucais no movimento ocluso-gengival. Porém, essa prótese também sofre forças de tração, por diversas situações clínicas, as quais levam a sela a se deslocar da fibromucosa num movimento gêngivo-oclusal. O objeto desta pesquisa foi desenvolver e testar, em laboratório, um método que possibilitasse à prótese mucosa-dento-suportada dispor de maior retenção na região da fibromucosa, reduzindo o movimento gêngivo-oclusal, e conferindo maior estabilidade à prótese e conforto ao paciente. Para realizar o experimento , foi construída uma base acrílica modificada, correspondente à sela da prótese, com uma canaleta na região que contata a fibromucosa. Esta canaleta foi preenchida com reembasador macio para prótese, à base de silicone. Em seguida, a base foi reembasada no modelo resiliente, especialmente construído para simular a fibromucosa. Uma haste metálica foi fixada em suas extremidades, sendo uma à base acrílica, e a outra extremidade fixada ao mandril do equipamento utilizado para o tracionamento (Versa-Test). Estando a base posicionada sobre o modelo, foram realizados os movimentos de pressão e de tração. A avaliação dos testes foi realizada na base acrílica convencional (sem canaleta) e na base acrílica modificada, cujos valores foram registrados em newton. As bases acrílicas sobre os modelos eram imersas em óleo vegetal, devido ao necessário meio viscoso, com tensão superficial, possibilitando os fenômenos de adesão. Os resultados demonstraram que, na presença de silicone, foi necessária força de tração maior e estatisticamente significante para remover a base do modelo, em relação à base sem silicone. / From the planning to the execution of the tissue-dento-supported prosthesis, the literature presents a range of works standing out the difficulties related to the prosthesis performance when facing distinctive tissues, tooth and fibromucous. These works approach the biomechanical problems and the damages suffered by osseous tissues and teeth under pressure, during the mastication, as well as the difficulties of distribution of the loads on oral tissues in the oclusal-gengival movements. However, this prosthesis also suffers traction forces, in several clinical situations, leading the saddle to move of the fibromucous in a gengival-occlusal movement. The aim of this research was to develop and to test, in a laboratory, a method to improve the tissue-dento-supported prosthesis retention in the fibromucous area reducing the gengival-occlusal movement and allowing a larger stability to the prosthesis and comfort to the patient. In order to accomplish the experiment, a modified acrylic base was confectioned, corresponding to the saddle of the prosthesis and constituted by a small channel in the fibromucous contact area. This channel was filled out with soft reliner for prosthesis, silicon composed. Afterwards, the base was rebased in the resilient model, especially confectioned to simulate the fibromucous. A metallic stem was fixed in two extremities, being one to the acrylic base, and other extremity fixed to the equipment arbor used for the traction (Versa-Test). With the base positioned on the model, the pressure movements and traction were accomplished. The evaluation of the tests was accomplished in the conventional acrylic base (without channel) and in the modified acrylic base, whose values were registered in Newton. The acrylic bases on the models were immersed in the vegetable oil, due to the necessary viscous condition, with superficial tension, making possible the adhesion phenomena. The results demonstrated that in the presence of silicon was necessary a larger and statistically significant traction force to remove the base of the model in relation to the base without silicon.
83

Avaliação dos dentes pilares e não pilares de indivíduos com fissura labiopalatina reabilitados com prótese parcial removível / Evaluation of abutment teeth and not abutment teeth of individuals with cleft palate rehabilitated with removable partial dentures

Danilo Tomazini Catalani 05 April 2013 (has links)
Objetivos: Neste estudo objetivou-se avaliar e comparar a condição periodontal de dentes pilares e não pilares de indivíduos com fissura labiopalatina reabilitados com prótese parcial removível instalada. Material e métodos: Pilares de 45 pacientes com fissuras labiopalatinas, de ambos os gêneros que utilizam prótese parcial removível, matriculados no Hospital de Reabilitação de Anomalias Craniofaciais, Universidade de São Paulo (HRAC-USP), com idade variando de 25 a 72 anos. Foram excluídos da amostra os indivíduos com alterações sistêmicas, doenças neurológicas, que tenham realizado tratamento periodontal prévio nos últimos seis meses, fumantes, gestantes, etílicos, usuários de drogas, que estavam fazendo uso de antidepressivos, antiinflamatórios, anticonvulsivantes, bloqueadores de cálcio ou qualquer fármaco que pudesse interferir nos resultados deste estudo. Os parâmetros clínicos avaliados por um único avaliador foram: medida de profundidade de sondagem, nível de inserção clínico, índice gengival, índice de placa, recessão gengival, quantidade de mucosa ceratinizada, com sonda periodontal, além das condições de higiene da prótese, classificação da área desdentada, classificação do tipo de grampo e foi aplicado o questionário de qualidade de vida. Resultados: Não houve diferença estatisticamente significante entre os dentes pilares e não pilares com exceção do nível de inserção clínico e profundidade de sondagem. As próteses de classe III foram as mais frequentes. Os escores 2 e 3 foram os mais frequentes dos índices de placa e Tarbet. O tipo de prótese, segundo a classificação de Kennedy não influenciou o OHIP-14. Os escores mais frequentes do OHIP-14 foram 0 e 1 . Conclusões: Os dentes pilares e não pilares das próteses parciais removíveis de indivíduos com fissura labiopalatina não apresentaram diferenças significativas nos parâmetros clínicos avaliados com exceção do nível de inserção clínico e profundidade de sondagem, aceitando-se parcialmente a hipótese nula. O tipo de grampo a classificação das próteses não tiveram influência na qualidade de vida. Os pacientes necessitam de melhor orientação de higiene oral já que os índices de placa e de Tarbet apresentaram médios a altos escores. / Purposes: This study aimed to evaluate and compare the periodontal status of abutment teeth and not abutment teeth of individuals with cleft palate rehabilitated with removable partial denture installed. Materials and Methods: abutment teeth of 45 patients with cleft lip and palate, of both genders using removable partial dentures, enrolled at the Hospital for Rehabilitation of Craniofacial Anomalies, University of São Paulo (HRAC-USP), aged 25-72 years. Were excluded from the sample individuals with systemic conditions, neurological diseases, who have made previous periodontal treatment in the last six months, smokers, pregnant women, ethyl, drug users, who were taking antidepressants, antiinflammatories, anticonvulsants, calcium blockers or any drug that could interfere with the results of this study. The clinical parameters assessed by a single evaluator were measured probing depth, clinical attachment level, gingival index, plaque index, gingival recession, amount of keratinized mucosa, periodontal probe, and the hygiene of the prosthesis, the classification edentulous area, type classification clamp was applied and the quality of life questionnaire. Results: There was no statistically significant difference between the abutment teeth and not abutment teeth except clinical the attachment level and probing depth. The prostheses of class III were the most frequent. The scores 2 and 3 were the most frequent plaque index and Tarbet. The type of prosthesis, according to the classification of Kennedy did not influence the OHIP-14. Scores Frequently OHIP-14 were 0 and 1. Conclusions: The abutment teeth and not abutment teeth of removable partial dentures for individuals with cleft palate showed no significant differences in clinical parameters evaluated with the exception of clinical attachment level and probing depth, partially accepting the null hypothesis. The type of staple sorting prosthesis did not influence the quality of life. Patients need better oral hygiene care, since the plaque index and Tarbet had medium to high scores.
84

Avaliação da eficiência e capacidade mastigatória em pacientes com fissura labiopalatina reabilitados com prótese de recobrimento / Evaluation of chewing ability and efficiency of patients with cleft lip and palate rehabilitated with prosthesis overlay

Rafael D'Aquino Tavano 15 April 2011 (has links)
Objetivou-se com este trabalho avaliar a capacidade e eficiência mastigatória de 37 pacientes com fissuras labiopalatinas, matriculados no Hospital de Anomalias Craniofaciais, Universidade de São Paulo (HRAC-USP) e 20 indivíduos não fissurados. O grupo 1 foi composto por 20 pacientes com fissura labiopalatina e dentição natural até pelo menos o 1º molar nos dois arcos dentários. O grupo 2 foi de 17 pacientes com fissura labiopalatina envolvendo rebordo, arco superior atrésico e com prótese parcial removível de recobrimento. Este grupo foi dividido nas condições sem a prótese (grupo 2a) e com a prótese (grupo 2b). O grupo 3 considerado grupo controle, foi formado por 20 indivíduos sem fissura, com dentição natural até pelo menos o 1º molar nos dois arcos dentários. Para a avaliação da capacidade mastigatória utilizou-se questionário padronizado, baseado na literatura, onde um único examinador limitou-se a explica-lo o questionário e não induziu as respostas. Para análise da eficiência mastigatória foram utilizadas amêndoas como alimento teste e sistema de tamises com peneiras e orifícios diferentes. Os resultados para a avaliação da capacidade e eficiência mastigatória indicaram que não houve diferença estatisticamente significante entre os grupos com fissura e com dentição natural (grupo 1 ) e grupo controle, sem fissura e dentição natural (grupo 3 ). Todavia, estes dois grupos apresentaram resultados melhores que o grupo com fissura e prótese parcial removível de recobrimento. Para os indivíduos com fissura e com prótese (grupo 2), a eficiência mastigatória foi melhor na condição com a prótese (grupo 2b) do que na condição sem a prótese grupo 2a). / This study aimed at evaluating the chewing ability and efficiency of 37 patients with cleft lip and palate attending the HRAC-USP and 20 individuals without clefts. Group1 comprised 20 patients with clefts presenting natural dentition at least up to the first molar in both dental arches. Group 2 was composed of 17 patients with clefts wearing removable partial dentures in at least one dental arch. This group was subdivided in group 2a comprised patients with clefts and without removable partial denture and group 2b, comprised patients with clefts and with removable partial denture. Group 3 (control) included 20 individuals without clefts presenting natural dentition at least up to the first molar in both dental arches. Evaluation of the chewing ability was performed by application of a literature-based standardized questionnaire in which only one examiner explained the questions and did not induce the responses. Analysis of chewing efficiency was conducted by utilization of almonds as test food and a system of sieves with different sizes and orifices. There was no statistically significant difference between groups 1 and 3 in relation to the chewing ability, but when compared groups 2b and 3, and groups 1 and 2b, there was statistically significant difference. Concerning evaluation of chewing efficiency, the individuals without clefts presented similar (statistically equal) outcomes compared to patients with clefts with natural dentition up to the first molar, with statistically better results when compared to those observed for patients with clefts wearing removable partial dentures, who were tested both with and without the prostheses. Patients with clefts with natural teeth presented better outcomes as patients wearing removable dentures either with or without their dentures in position. Comparison within the group of patients with clefts wearing removable partial dentures revealed that their chewing efficiency was statistically better when their dentures were in position.
85

Efeito de soluções higienizadoras diárias em ligas de cobalto-cromo e resina acrílica termopolimerizável para prótese parcial removível. / Effect of denture cleansers on the properties of removable partial denture: in vitro study.

Daniela Nair Borges Felipucci 09 October 2009 (has links)
A higienização das próteses removíveis é fundamental para a longevidade do tratamento e prevenção de patologias orais. O objetivo deste estudo foi avaliar o efeito de higienizadores de imersão nas superfícies da liga metálica e resina acrílica termopolimerizável de Prótese Parcial Removível (PPR), simulando 180 dias. Discos (12 mm x 3 mm) foram confeccionados com ligas metálicas de cobalto-cromo para PPR: Vera PDI® (VP) e DeguDent® (DD). Cada disco metálico foi incluído em mufla previamente preparada por matrizes de teflon (38 mm x 18 mm x 4 mm), incorporando-se o disco metálico à resina acrílica termopolimerizável. Os espécimes (n= 5) foram imersos nas seguintes soluções: água destilada (grupo controle - AD), hipoclorito de sódio 0,05% (HS), Cepacol® (cloreto de cetilpiridínio 0,005% - CE), Periogard® (digluconato de clorexidina 0,12% - PE), Corega Tabs® (peróxido alcalino e enzima - CT), Polident® (peróxido alcalino e enzima - PO) e Medical Interporous Dentures® (ácido cítrico - MI). Foram realizadas análise da estabilidade de cor por meio de espectrocolorímetro, análise visual da presença de manchas no metal, análise da perda de massa em balança de alta precisão e análise da rugosidade por meio de rugosímetro. Como estudo complementar, foram realizadas análises quantitativas da liberação de íons (cobalto e cromo) em cada solução com espectrômetro de massas e análises ópticas e qualitativas com microscópio eletrônico de varredura (MEV) e espectrometria de energia dispersiva de Raios-X (EDS). Os resultados de rugosidade, alteração de cor e massa apresentaram distribuição normal e homogênea, tendo sido submetidos à ANOVA e teste de Tukey (p< 0,05). Quanto à rugosidade (Ra&micro;m), não houve diferença estatisticamente significante entre as soluções e ligas tanto para o metal quanto para a resina. Com relação à alteração de cor da resina acrílica termopolimerizável (&Delta;E), houve diferença estatisticamente significante entre as ligas, soluções e na interação liga x solução. As soluções AD, CE e PE propiciaram menores valores que as demais. A resina associada à DD apresentou maior alteração de cor do que quando associada à VP (1,06 ± 0,51 e 0,51 ± 0,28, respectivamente). Com relação à presença de manchas no metal, o HS propiciou manchamento em 100% dos espécimes. O grupo MI/DD propiciou em 60% e o MI/VP em 40% dos espécimes. Quando avaliada a alteração de massa (g), as soluções CT e MI propiciaram maiores valores. Entre as ligas, a VP apresentou maior perda de massa. Com relação à liberação de íons cobalto e cromo, a solução de HS e a MI propiciaram maior liberação e quando comparadas as ligas, VP apresentou maior liberação de íons. Com o MEV pôde-se verificar que houve corrosão generalizada com o HS e por pites com a MI. Concluiu-se que as soluções CE, PE e PO não apresentaram efeitos deletérios podendo ser auxiliares à escovação para higienização de PPR. / The hygiene care of the removable dentures is required for the longevity of the treatment and prevention of oral diseases. The aim of this study was to evaluate the effect of denture cleansers on the surfaces of the alloys and heat-polymerized acrylic resin for removable partial denture (RPD), simulating a period of 180 days. Circular specimens (12 mm x 3 mm) had been fabricated with cobalt-chromium alloys: Vera PDI&trade; (VP) and DeguDent&trade; (DD). The cast specimens were centered in the moulds previously prepared by matrices of teflon (38 mm x 18 mm x 4 mm) and the acrylic resin was inserted. The specimens (n= 5) had been immersed in the following solutions: distilled water (control - DW), sodium hypochlorite 0.05% (SH), Cepacol&trade; (cetilpiridinium chloride 0.005% - CE), Periogard&trade; (chlorexidine gluconate 0.12% - PE), Corega Tabs&trade; (alkaline peroxide and enzyme - CT), Polident&trade; (alkaline peroxide and enzyme - PO) and Medical Interporous Dentures&trade; (citric acid - MI). The color stability was analyzed using a colorimeter, and the presence of tarnishes on the metal was performed by a visual analysis. The weight loss was measured with a precision balance and the surface roughness was analyzed with a surf-test analyzer. As complementary analyzes a quantitative study of ions release (cobalt and chromium) using inductively mass spectrometry and optical and qualitative analyses with scanning electron microscopy (SEM) associated to dispersive energy spectrometry were performed. The results of roughness, color stability and weight loss presented normal and homogeneous distribution and were submitted to ANOVA (p &le; 0.05) and Tukey test. There was no significant difference among the solutions and between the alloys for both metal and resin roughness (Ra &micro;m). The acrylic resin color stability (&Delta;E) was analyzed and showed significant difference among the solutions, alloys and interaction. AD, CE and PE solutions presented the lowest values of color changes. The resin associated to DD presented higher color change than when associated with the VP (1.06 ± 0.51 and 0.51 ± 0.28, respectively). The HS caused tarnishes on 100% of specimens. The MI/DD group provided 60% and the MI/VP in 40% of specimens. When was analyzed the mass loss (g), the solutions CT and MI had the higher values. Between the alloys VP presented higher weight loss. HS and MI presented greater ionic release and between the alloys, VP presented greater release. With the SEM it was possible observe the presence of widespread corrosion in the HS group and pites corrosion in the MI group. It was concluded that CE, PE, CT and PO solutions had no deleterious effects on the compounds of RPD and may be indicate as auxiliaries to brushing in the RPD hygiene care.
86

Estudo longitudinal da influencia da protese parcial removivel no indice de estreptococos do grupo mutans na saliva, e de medidas preventivas para redução deste atraves do controle quimico

Rocha, Eduardo Passos 20 August 1999 (has links)
Orientador: Altair A. Del Bel Cury / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-25T04:05:54Z (GMT). No. of bitstreams: 1 Rocha_EduardoPassos_M.pdf: 8338827 bytes, checksum: a8aba43a0026699db752f3c1473b688b (MD5) Previous issue date: 1999 / Resumo: Parte da literatura relaciona o uso da prótese parcial removível (PPR) com níveis diferenciados de estreptococos do grupo mutans (EGM). No entanto, os relatos são inconclusivos e os trabalhos que associam medidas preventivas de controle químico são poucos e inexistentes a longo prazo. Dessa forma, o objetivo do trabalho foi avaliar a influência da PPR no índice de EGM na saliva, e o seu controle químico com o uso do gel de digluconato de clorexidina a 1 % (CHX). Para tanto, amostras de saliva foram coletadas imediatamente antes da instalação da PPR (tempo zero=T0), 8 dias após (T8), 48 dias após (T 48), 92 dias após (T92), 140 dias após (T140) e 189 dias após a instalação da PPR (T189). Estas foram homogeneizadas em agitador de tubos (Vortex) por 1 min. Diluições seriadas de '10 POT. ¿1' a '10 POT. ¿6' foram realizadas em solução estéril de tampão fosfato, 0,05 M, pH 7,0. Em duplicata, alíquotas de 25 'muL' foram semeadas em placas de petri contendo ágar MSB. A seguir, as placas foram incubadas em estufa de C02 (5%), a 37°C, por 72 horas. Os resultados apresentaram diferença estatística (Test t, p<0,05) entre os valores de T0 e T48, respectivamente: (média/desvio-padrão em UFC de EGM/mL de saliva) 2,26 x '10 POT. 6'/4,43 x '10 POT. 6' e 4,79 x '10 POT. 7'/1,48 x '10 POT. 8'. Decorrido esses períodos, a CHX foi aplicada em 29 voluntários, não sendo eficaz na redução dos níveis de EGM (Test t, p>0,05). Novas amostras de CHX foram formuladas e avaliadas quanto à efetividade. A nova formulação foi aplicada em 15 voluntários. Amostras de saliva foram coletadas nos períodos: antes da aplicação da clorexidina (tempo zero=T0), 24 horas após (T24h) e 82 dias após (T82). Os resultados apresentaram diferença estatística (Sign Rank, p<0,05) entre os valores de T0 e T24h, respectivamente: (média/desvio-padrão em UFC de EGM/mL de saliva) 6,64 x '10 POT. 6'/8,47 x '10 POT. 6' e 3,20 x '10 POT.5'/4,27 x '10 POT. 5'. O índice de EGM na saliva retomou aos valores iniciais num período de 82 dias (T82). Concluiu-se Que o uso da PPR promoveu aumento significativo do índice de EGM após 48 dias de instalação da prótese e Que o gel de clorexidina a 1 % foi eficaz na redução do índice de EGM num intervalo de tempo entre 24h e 82 dias após a segunda aplicação / Abstract: Many studies have reported an evaluating of the salivary levels of MS in patients submitted to oral rehabilitation with RPD. Thus, after subscription of consent term and approval of ethic committee, saliva samples (2.0 mL) were obtained from 32 patients in 6 periods: (T0): immediately before installation of RPD; (T8): 8 days after T0; (T48): 48 days after T0; (T92): 92 days after T0; (T140): 140 days after T0 and (T189): 189 days after T0. The samples were vortexed and serially diluted from '10 POT. ¿1' to '10 POT. ¿6' in 0.05 M phosphate buffer in the number of MS in saliva between the periods T0 and T48 (mean/SD, CFU/mL saliva): T0: 1.90/4.02 x '10 POT. 6' and T48: 0.38/1.33 x '10 POT. 8'. After this, intensive treatment with CHX was (pH 7.4). From each dilution, 0.025 mL was plated on MSB. The plates were incubated in 5% COz at 37°C for 72 hours. There was a statistically significant increase (Test t, p<0.05) accomplished in 29 patients. Saliva samples (2.0 mL) were obtained after treatment in 4 periods: (T24h): 24 hours after T24h; (T14): 14 days after T24h; (T28): 28 days after T24h and (T63): 63 days after T24h. After treatment with CHX, the number of MS in saliva did not decrease (Test t, p>0.05). A new CHX formulation was applied in 15 patients. Saliva samples (2.0 mL) were obtained in periods: (T0): before CHX; (T24h): 24 hours after T0 and (T82): 82 days after T0. The new CHX reduced the MS in periods T0 and T24h: (mean/SD, CFU/mL saliva): T0: 6.64/8.47 x '10 POT. 6' and T24h: 3.2/4.27 x '10 POT. 5' (Sign Rank, p<0.05). In conclusion, there was a significant increase in the number of MS in saliva after installation of RPD and that the intensive treatment with a properly formulated 1 % chlorhexidine gel was effective in the reduction of MS between 24h and 82 days after new appliance of CHX / Mestrado / Protese Dental / Mestre em Clínica Odontológica
87

Resistencia a fadiga do titanio comercialmente puro e de liga Ti-6Al-4V em diferentes meios de armazenagem / Fatigue strength of commercially pure titanium and TI-6Al-4V alloy in different storage media

Zavanelli, Ricardo Alexandre 04 September 1999 (has links)
Orientador: Guilherme Elias Pessanha Henriques / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-25T08:20:05Z (GMT). No. of bitstreams: 1 Zavanelli_RicardoAlexandre_M.pdf: 5267255 bytes, checksum: 6668bbd1a4fe3d55e1241b830baee2a7 (MD5) Previous issue date: 1999 / Resumo: A fadiga é responsável por 90% das falhas de infra-estruturas metálicas em serviço. Esse fenômeno está intimamente relacionado às alterações superficiais e ocorre devido à aplicação de esforços cíclicos. As PPRs sofrem fadiga devido às constantes inserções e remoções e durante o próprio ato mastigatório. Devido a propriedades como biocompatibilidade e resistência mecânica, tem-se introduzido o uso do titânio e suas ligas na confecção de coroas e próteses, sendo consideradas susceptíveis de alterações superficiais devido ao uso de soluções fluoretadas. O propósito deste estudo foi avaliar, comparar e analisar a vida em fadiga do titânio comercialmente puro e da liga Ti-6Al-4V em diferentes meios de armazenagem (sem a presença de meios; em saliva artificial; e, em saliva artificial fluoretada). Foram confeccionadas trinta amostras para cada um dos materiais, com geometria semelhante a um halteres e 2,3 mm de diâmetro na porção central, obtidas por fundição odontológica, em máquina de fundição Rematitan (Rematitan - Dentaurum J.P. Winkelstroeter KG- Pforzhein - Alemanha). O ensaio de resistência à fadiga foi conduzido numa máquina de ensaios universal (MTS - Materials Testing System, Test Star II), com carga 30% abaixo e calculada a partir do limite de escoamento a 0,2% de deformação. Após a fratura, o número de ciclos foi registrado e a superfície de fratura analisada sob microscopia eletrônica de varredura (M.E.V.). Os resultados indicaram que a liga Ti-6Al-4V obteve 21,269.50 ciclos, contra 19,157.60 ciclos para o Ti c.p., e na presença das soluções esse número diminuiu drasticamente, sugerindo provável reação dos meios com os metais. Com base nos resultados obtidos, verificamos que: A liga Ti-6Al-4V obteve os maiores valores médios de resistência à fadiga, porém sem diferença estatisticamente significante em relação ao titânio puro, independente da presença dos meios de armazenagem. A presença das soluções de armazenagem diminuiu a resistência à fadiga para ambos materiais, com diferença estatisticamente significante em relação às amostras ensaiadas sem a presença dos meios. A solução de saliva artificial fluoretada pareceu mais agressiva. Entretanto, não houve diferença estatística em relação à solução de saliva artificial / Abstract: The fatigue is responsible for 90% of metallic component failures during service. This phenomenon is closely related to superficial alteration and it occurs during cyclic stress application. Removable partial dentures (RPDs) are affected by fatigue due to cyclic mechanism of the masticatory system and the frequent insertion and removal. Because of unique and favorable properties, titanium and its alloys have been used in manufacturing crowns and bridges. However, it has been shown that preventive agents with fluoride probably affect titanium alloy surfaces. The aim of this study was to evaluate compare and analise the fatigue life of commercially pure titanium and Ti-6Al-4V alloy in different media (without media, artificial saliva and fluoride artificial saliva). For each alloy, thrirty dumb-bell rods 2.3 mm in diameter were.cast in Rematitan-System (Rematitan-Dentaurum IP. Winkelstroeter KG-Germany). The fatigue strength test was carried out with an universal testing machine (MTS- Materials Testing System - Test Star II), using a load 30 % lower than the calculated yield strength at a 0.2% offset. After failure, the number of cycles were recorded and the fracture surfaces were examined with a scanning electron microscope (S.E.M.). The mean values indicated that Ti-6Al-4V alloy achieved 21,269.50 cycles against 19,151.60 cycles for the c.p. titanium, and, when the solutions were present, the number of cycles was drastically reduced, probably due to pits caused by superficial reactions, as showed in S.E.M. analyses. It was observed that: Ti-6Al-4V alloy had the highest mean values of fatigue strenght, however, there were no siglificant differences as regards c.p. titanium. free-standing the presence or absence of media; the solutions reduced fatigue strength for both alloys, with statistically significant differences to specimens tested without the solutions; the fluoride solution was the most harmful agent, but there were no significant differences between fluoride solution and artificial saliva / Mestrado / Protese Dental / Mestre em Clínica Odontológica
88

Avaliação longitudinal do efeito do uso de proteses parciais removiveis sobre os tecidos periodontais : estudo clinico e bioquimico

Pinto, Fernando Rodrigues 25 January 2005 (has links)
Orientador: Sergio de Toledo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T06:56:35Z (GMT). No. of bitstreams: 1 Pinto_FernandoRodrigues_D.pdf: 254395 bytes, checksum: e7aa584ae3a971974f0129d6af2c160e (MD5) Previous issue date: 2005 / Resumo:A doença periodontal tem como fator etiológico primário o acúmulo de biofilme dental que pode ser favorecido por uma grande variedade de fatores retentivos locais, como por exemplo, próteses parciais removíveis, que podem alterar a progressão e o risco da doença. O objetivo deste trabalho foi avaliar o efeito do uso de próteses parciais removíveis (PPRs) sobre as condições clínicas periodontais e alterações qualitativas do biofilme dos dentes suportes por um período de dois anos. Foram selecionados 13 pacientes com média de idade de 55,8 (±14,8) anos, de acordo com os seguintes critérios: parcialmente dentados e que não utilizaram PPRs nos últimos 18 meses previamente ao início do estudo, sem envolvimento sistêmico e não fumantes. Os seguintes parâmetros clínicos periodontais foram avaliados: Índice de Placa de Silness & Löe (1964) ¿ IPL, o Índice Gengival de Löe (1967) ¿ IG, profundidade de sondagem ¿ PS, recessão gengival - RG e Nível de inserção clínico ¿ NIC; medidos através de uma sonda periodontal eletrônica de pressão controlada (Florida Probeâ, Gainesville, FL, USA). A atividade de enzimas tipo tripsina no biofilme dental dos dentes suportes foi analisada por um teste enzimático (teste BAPNA). Os dados foram coletados em quatro períodos experimentais: T0 = antes da reabilitação protética, T6 = após 6 meses de uso, T18 ¿ 18 meses e T24 após 24 meses de uso continuado das próteses. Os resultados obtidos em todos os períodos (T0, T6, T18 e T24) foram respectivamente: valores medianos para IPL (1, 1, 1 e1) e IG (0, 0, 1 e 1), valores médios e desvio padrão para PS (2,3mm ±0,3; 2,28mm ±0,4; 2,17mm ±0,2 e 2,26mm ±0,3), RG (0,78mm ±0,7; 0,87mm ±0,7; 0,87mm ±0,7 e 0,95mm ±0,8), NIC (3,08mm ±0,8; 3,15mm ±0,9; 3,04mm ±0,9 e 3,21mm ±0,9) e teste BAPNA (5,479 nmol/mg de biofilme X min ±2,2; 6,22nmol/mg de biofilme X min ±2,9; 8,199 nmol/mg de biofilme X min ±2,7 e 13,852 nmol/mg de biofilme X min ±11,7). A análise estatística demonstrou diferença para o índice gengival entre os períodos T24 e T18 em relação ao T0 e do T24 para T6 (p<0,05) e também para o teste BAPNA entre os períodos T24 e T18 em relação ao T0 e do T24 para T6 (p<0,05) indicando aumento na atividade enzimática. Concluiu-se que a simples presença das próteses parciais removíveis, mesmo em pacientes com adequado controle de placa, foi capaz de alterar um parâmetro indicativo de inflamação gengival e a composição qualitativa do biofilme destes pacientes durante um período de dois anos de uso das próteses / Abstract: The dental biofilm is the primary etiological factor of the periodontal disease and its accumulation can be influenced by a great variety of local factors, such as removable partial dentures. The aim of this study was to evaluate the possible influence of the presence of removable partial dentures (RPDs) on the periodontal clinical parameters and in the dental biofilm of the connectors¿ teeth. Thirteen partially edentulous volunteers with a mean age of 55.8 (±14.8), without RPDs, no systemic diseases, no smokers were selected. The following clinical parameters were evaluated: Plaque Index (Silness & Löe, 1964) PI, Gingival Index (Löe, 1967) GI, Probing Depth - PD, Gingival Recession ¿ GR and Clinical Attachment Level ¿ CAL; PD, GR and CAL were obtained with an electronic computerized probe (Florida Probeâ, Gainesville, Fla, USA). The tripsin-like activity on the biofilm of the connectors¿ teeth was evaluated by an enzymatic test (BAPNA). The data were collected in four experimental periods: T0 = before the rehabilitation, T6 = six months after rehabilitation, T18 = eighteen months and T24 = 24 months of continuous use of RPDs. The clinical measurements in T0, T6, T18 and T24 were respectively: median value for PI (1, 1, 1, 1) and GI (0, 0, 1, 1); mean value and standard deviation for PD (2.3mm ±0.3; 2.28mm ±0.4; 2.17mm ±0.2 e 2.26mm ±0.3), GR (0.78mm ±0.7; 0.87mm ±0.7; 0.87mm ±0.7 e 0.95mm ±0.8), CAL (3.08mm ±0.8; 3.15mm ±0.9; 3.04mm ±0.9 e 3.21mm ±0.9). For the trypsin-like activity in T0, T6, T18 and T24 the mean value and standard deviation were T0 ¿ 5.479nmol/mg of biofilm X min ±2.2, T6 ¿ 6.22nmol/mg of biofilm X min ±2.9, T18 ¿ 8.199 nmol/mg of biofilm X min ±2.7 and T24 ¿ 13.852 nmol/mg of biofilm X min ±11.7. Statistical analysis showed differences for GI for T18 and T24 compared to T0 and T24 compared to T6 (p<0.05) and the same was observed for BAPNA harboring differences for T24 and T18 compared to T0 and between T24 and T6. It was concluded that, even in patients with good plaque control, the presence of Removable Partial Dentures does altered the health status of periodontal tissues and the trypsin-like activity of dental biofilm over a period of two years of continuous use of RPDs / Doutorado / Periodontia / Doutor em Clínica Odontológica
89

Water sorption, solubility and load transmission of removable partial dentures manufactured with poly (methilmetacrilate) and polyamide = Sorção de água, solubilidade em água e transmissão de forças de próteses parciais removíveis confeccionadas em poli (metilmetacrilato) e poliamida / Sorção de água, solubilidade em água e transmissão de forças de próteses parciais removíveis confeccionadas em poli (metilmetacrilato) e poliamida

Panza, Leonardo Henrique Vadenal, 1982- 24 February 2015 (has links)
Orientadores: Wander José da Silva, Altair Antoninha Del Bel Cury / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-27T04:08:04Z (GMT). No. of bitstreams: 1 Panza_LeonardoHenriqueVadenal_D.pdf: 39498694 bytes, checksum: bcb5576864f239980a74f85ecab13ee6 (MD5) Previous issue date: 2015 / Resumo: O uso de PPRs continua como uma alternativa viável e eficiente na prática da reabilitação oral, no entanto a necessidade do uso de uma estrutura metálica, pode muitas vezes causar um comprometimento estético. O uso de materiais alternativos flexíveis para a substituição destes grampos ou de outras partes da PPR tem sido bastante divulgado, porém ainda existem controvérsias sobre as propriedades físicas e mecânicas dos mesmos. O objetivo deste trabalho foi comparar 2 materiais utilizados na confecção de PPRs nos quesitos sorpção de água, solubilidade em água e transmissão de forças ao rebordo na extensão distal da peça. Para análise de sorpção e solubilidade foram confeccionados discos em polimetilmetacrilato (PMMA) e poliamida (POL), seguindo as especificações da ISO 1567. Para análise da transmissão de forças ao rebordo foram confeccionados modelos classe I de Kennedy em resina fotoelástica e 3 diferentes tipos de PPR: tradicional com estrutura metálica e base em PMMA (controle), PPR conjugada feita com estrutura metálica e poliamida e uma PPR confeccionada totalmente em poliamida. Os conjuntos modelo-PPR foram submetidos à cargas de 0,5 e 1,0 KgF na extensão distal e as imagens de franjas formadas nos modelos foram capturadas de forma padronizada. O teste de Kruskal-Wallis foi utiilizado para analisar os dados, que mostraram não haver diferenças significantes entre os materiais para sorpção de água (p=0.6682) e solubilidade (p=0.4095). A análise fotoelástica mostrou uma transmissão de forças mais intensa pela extensão distal da PPR nos grupos de PPRs feitas em poliamida, quando comparadas ao grupo controle, especialmente no grupo da PPR sem metal. Com as limitações deste estudo foi possível concluir que o comportamento do PMMA e da poliamida foi similar para sorpção e solubilidade em água e que a transmissão de forças ao rebordo em próteses confeccionadas em poliamida sem metal contraindicam o seu uso / Abstract: The use of removable partial denture (RPD) still remains as a viable alternative to an efficient oral rehabilitation. However, due the metal framework lack of esthetic, it has been suggested the use of flexible materials as substitutes to the metal clasps, even thought this material maintains controversial regarding its dimensional properties. In this manuscript, our group compared two materials used in the fabrication of RPD regarding its water sorption and solubility and load transmission by distal extension. For this, poly (methyl methacrylate) (PMMA) and polyamide (POL) discs (n=7) were used to manufacture specimens that were evaluated regarding its water sorption and solubility. For load transmission by distal extension, Kennedy Class I mandibular models were made with photo elastic resin and 3 different RPD were tested: traditional RPD with metal framework and PMMA flange (Control); RPD with metal framework and clasps and flange in POL (POL-Metal); and RPD totally manufactured in POL (TOT-POL). Load of 0.5 and 1.0 kgF were applied to distal extension and the image of the load transmission in the photo-elastic model was captured. Kruskal-Wallis test were used for data analysis. Results showed no statistical difference between both materials regarding water sorption (p=0.6682) and solubility (p=0.4095). Photo-elastic analyses showed higher load transmission by distal extension by both POL group when compared to control group. Within the limitations of this study, it can be concluded that although POL had similar behavior to PMMA regarding water sorption and solubility, the load transmission by distal extension in RPD manufactured with POL shows the worst results, but clinical studies should de done with this material to indicates its use / Doutorado / Protese Dental / Doutor em Clínica Odontológica
90

Avaliação da eficiência mastigatória em pacientes com prótese parcial removível classe I inferior e prótese total superior de Porto Velho-RO

Ilza Caixeta e Silva Camargo 16 July 2008 (has links)
O objetivo deste estudo foi avaliar a eficiência mastigatória de usuários de prótese parcial removível (PPR) classe I inferior e prótese total (PT) superior, da cidade de Porto Velho - Rondônia, e comparar os resultados obtidos com os descritos na literatura, utilizando a mesma metodologia. Dez indivíduos (cinco do gênero feminino e cinco do gênero masculino) totalmente dentados foram selecionados para o grupo controle. Vinte e sete indivíduos, de ambos os gêneros, receberam 17 cubos de Optocal (simulador de alimento) os quais foram mastigados em vinte ciclos (golpes) mastigatórios. O mesmo procedimento foi repetido posteriormente, desta vez com quarenta ciclos. Os fragmentos foram passados por oito peneiras granulométricas calibradas (5,6; 4,0; 2,8; 2,0; 1,4; 1,0; 0,71 e 0,5 mm) e depositado em um coletor sem perfurações. O material triturado, retido em cada peneira e no coletor, foi secado em estufa e pesado. Os valores foram tabulados em tabela e analisados. Após a mastigação, os indivíduos responderam um questionário para qualificar o alimento utilizado quanto à natureza, consistência, influência do sabor e grau de dificuldade de mastigação. Os resultados mostram melhor eficiência mastigatória em pacientes totalmente dentados, com quarenta ciclos mastigatórios e que, para compensar o fraco desempenho mastigatório das próteses removíveis, os pacientes devem realizar mais golpes mastigatórios. / The aim of this study was evaluate the masticatory efficiency of removable partial denture (RPD) of wearers class I mandibular and complete denture maxillar in Porto Velho, Rondônia. Ten completely dentate subjects (five women and five men) were selected to the control group. Twenty seven subjects both gender were selected and received 17 Optocal cubes (food simulator) that were chewed in twenty chewing strokes. The same procedure was used on late with forty chewing strokes. The fragments of Optocal were sieved on stacks of eight sieves, with apertures from 5,6 decreasing to 0,5 mm (5,6; 4,0; 2,8; 2,0; 1,4; 1,0; 0,71 e 0,5 mm), and a bottom plate. The amount of test food on each sieve and on the bottom plate was dried and measured. The results were tabled and analyzed. After the chewing test, the subjects answer a questionnaire to qualify the test food in relation to hardness, consistency and difficulty to chew. The results show better masticatory efficiency in subjects completely dentates with 40 chewing strokes and that, to compensate the removable denture low performance, the patients must do extra masticatory bites.

Page generated in 0.046 seconds