• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 19
  • 19
  • 19
  • 11
  • 11
  • 7
  • 6
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Caracterização de impacto ambiental no solo em um aterro de pequeno porte

Bellezoni, Rodrigo Augusto [UNESP] 27 August 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:30Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-08-27Bitstream added on 2014-06-13T19:38:36Z : No. of bitstreams: 1 bellezoni_ra_me_bauru.pdf: 3031269 bytes, checksum: fb9929ec904e2ea3a2320a92f75db9df (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A disposição de resíduos sólidos no solo gera frequentes preocupações ambientais, sociais e de saúde pública. Os aterros sanitários de pequeno porte são uma alternativa sugerida por órgãos ambientais no Estado de SP para que pequenos municípios possam destinar seus resíduos de forma ambientalmente segura, a custos reduzidos. Esta pesquisa teve como objetivo avaliar, sob a análise de aspectos físicos e geofísicos, se este mecanismo possui capacidade em conter os líquidos percolados das colunas de resíduos, evitando riscos de contaminação no solo e águas subterrâneas. Para tanto, características físicas da área de influência do aterro foram determinadas com auxílio de mapas, assim como as características físicas foram determinadas através de ensaios padrão. O método da Eletrorresistividade foi empregado para caracterizar o solo em subsuperfície e estimar sua capacidade na atenuação de contaminantes. Os resultados mostraram o potencial de aplicação deste método, através da relação entre elevada carga iônica e baixa resistividade elétrica, definindo com clareza o limite das plumas de contaminantes. O chorume ocorre em grande parte das valas mais recentes, devido à etapa de decomposição. Valas antigas apresentaram tendência de aumento na resistividade, significando queda na geração de chorume, concomitante ao aumento do tempo de resistividade dos resíduos. Assim, a zona de influência dos resíduos limitou-se à 20 m da área de disposição no plano horizontal e até 8,5 em profundidade. As propriedades físico-químicas do solo argiloso local influenciaram o comportamento da pluma de contaminantes, visto a redução destas ao longo do tempo. Destacam-se o mineral de argila e a granulometria como os possíveis principais responsáveis pela atenuação natural dos contaminantes. Em alguns... / The disposal of solid waste in the soil often creates environmental, social and public health concerns. Small landfills are an alternative suggestion by environmental agencies in the State of São Paulo so small cities direct their waste in an environmentally safe manner, at costs. This research is aimed to evaluate, under the analysis of physical and geophysical concepts, if this mechanism has the capacity to contain lanchated liquid from the columns of waste, avoiding risks of contamination in soil and groundwater. Thus, physical characteristics of landfill catchment area were determined with the aid of maps, as well as the physical characteristics of the local soil were determined by standard assays. The Electrical Resistivity method was employed to characterize the subsoil and to estimate its ability to attenuate contaminants. The results showed the potential application of this method through the relationship between hhigh ionic charge and low resistivity, defining clearly the limits of contaminant plumes. Leachate occurs largely in the more recent dithes, due to the decomposition phase. Older ditches tended to increase in resistivity; it means decrease of leachate generation, as well the increase of waste time residence. Thus, the waste influence zone was limited to 10 m of the disposal area in the horizontal plane and up to 8.5 m in depth. The physicochemical properties of the clay soil spot have influenced the contaminants plume behavior, to reduce it along the time. Emphasizing this are the clay mineral and grain size held as possible primary accountable for natural attenuation of contaminants. At some ponts, it is estimated that the layer of unsaturated soil under the ditches be less that one meter, it does not comply the criteria for exemption of additional waterproofing, established in NBR 15.849:2010 Municipal solid waste... (Complete abstract click electronic access below)
12

Projeto e implementação de um filtro ativo universal trifásico controlado digitalmente

Melo, Priscila Facco de 15 December 2010 (has links)
Este trabalho apresenta o desenvolvimento e a implementação de um filtro ativo trifásico universal, o qual é composto pela conexão de três módulos monofásicos. Cada módulo monofásico é independente e é controlado por um processador digital de sinais. A estrutura de potência utilizada em cada módulo é uma topologia de três braços em que dois conversores compartilham um braço, de forma que o circuito apresenta número de componentes de potência reduzido na versão monofásica e pode operar sem o uso de um transformador. O filtro ativo proposto é capaz de compensar a distorção harmônica e regular o nível da tensão entregue para a carga. Ele também compensa a corrente da carga conectada na saída do filtro, corrigindo seu conteúdo harmônico e fator de potência. Apresenta-se uma revisão bibliográfica sobre alguns assuntos referentes à qualidade de energia elétrica, como os conceitos de distorção harmônica, seus efeitos e as normas pertinentes. Em seguida, as principais topologias de filtros ativos são apresentadas. Três módulos monofásicos, de 1500 W cada, são implementados e o funcionamento da estrutura de três braços, bem como os principais parâmetros do circuito de potência são analisados. Um algoritmo PLL (Phase Locked Loop) digital é empregado para o sincronismo de cada módulo. Controladores repetitivos são utilizados para o controle da tensão e da corrente. Os detalhes da estratégia de controle, bem como o projeto do circuito de sincronismo e dos controladores digitais são apresentados. Os resultados teóricos obtidos são comprovados através da simulação e da experimentação do protótipo implementado. A utilização do filtro ativo possibilitou a redução do conteúdo harmônico das cargas utilizadas nos testes, bem como elevou o fator de potência e corrigiu a distorção e o nível da tensão entregue para a carga. / This paper presents the development and implementation of a three-phase universal active filter consisting of three single-phase modules. Each single-phase module is independent and is controlled by a digital signal processor. The power structure used in each module is a three-arm topology in which two converts share one arm, so that the circuit has a reduced count of components and can operate without using a transformer. The proposed active filter can compensate harmonic distortion and adjust the voltage level delivered to the load. It also compensates the load current connected to the filter output, correcting its harmonic content and power factor. It presents a literature review on some issues related to power quality, as the concepts of harmonic distortion, its effects and relevant standards. Then the principal topologies used in active filters are presented. Three single-phase modules, each one of 1500 W, are implemented and the operation principles of the three-arms structure and the main parameters of the power circuit are analyzed. A digital PLL (Phase Locked Loop) is employed to synchronize each module. Repetitive controllers are used to control the voltage and current. Details of the control strategy and circuit design of the synchronism and digital controllers are presented. The results are verified through simulation and experimentation of the implemented prototype. Using the active filter was possible to reduce the harmonic content of the loads used in the experimental tests as well as increasing the power factor and to correct the distortion and voltage level supplied to the load.
13

Análise da vida útil estimada das edificações baseada na norma de desempenho (ABNT NBR 15.575:2013)

Silva, Nina Celeste Macario Simões da 25 February 2016 (has links)
Made available in DSpace on 2017-06-01T17:57:36Z (GMT). No. of bitstreams: 1 nina_celeste_macario_simoes_silva.pdf: 1909483 bytes, checksum: 6aea96fc0ed64d2a0e30e39d5ce2096f (MD5) Previous issue date: 2016-02-25 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Analysis of service life of a building requires the observation of many variables, especially corre-lating to the performance and durability. In this meaning, the NBR 15.575:2013 - Residential Buildings - Performance establishes requirements, criteria and methods assessment for analyz-ing the performance of buildings, and sometimes subsidize designers to determine the design life consistent with the performance level desired by the builder and user. Adding that the calculation of the estimated service life of buildings takes into account the natural aging of the building sys-tems components, but not contemplates of the damage effect caused by the entry into operation and use of the building or absence conservation. Moreover, the NBR 5.674:2012 - Buildings Maintenance - Requirements for the maintenance management system, indicates which systems and services that must go through the maintenance process and in what period, enabling mainte-nance management quality. However, it is not always what happens in the buildings after entry into operation and use. In the survey, we tired so verify the relationship between the predicted service life and the warranty period of the building. The information analyzed were provided by an active construction of Recife, collected in a database from the technical assistance after work eight buildings in the Metropolitan Region of Recife. To measure the percentage difference be-tween the design life and estimated service life, following the intervention of the technical assis-tance after work was used the factors method set out in ISO 15.686:2000 - Building and construc-tion assets - Service life planning and recommended by NBR 15575-1:2013. The frequency of occurrence damage in buildings was analyzed by determining the rates of failure in the buildings. The results show to a reduction of the design life of the order of 20% of the reference service life, from values adopted in the Performance of Brazilian Standard; also point to a concentration of damage in the initial stage of construction, above 50%, which correlate with the conditional prob-ability of failure curve (Bathtub Curve) sorting a high abrupt failure rate, ranking the building at the stage of infant mortality. These results reflect an unplanned variation in performance level proposed for the building. In this context, it is suggested to link the period of the works guarantee to the level of actual performance of the building. The application of reliability concepts allows infer about warranty period of the Building and make comparisons with the requirement of Brazi-lian law enforcement. / A análise da vida útil (VU) de uma edificação exige a observação de muitas variáveis, especialmente aquelas voltadas para o desempenho e durabilidade. Nesse sentido, a ABNT NBR 15.575:2013 Edificações habitacionais Desempenho estabelece requisitos, critérios e métodos de avaliação para analisar o desempenho das construções, e ao mesmo tempo subsidiar os projetistas a determinar a vida útil de projeto (VUP) condizente com o nível de desempenho desejado pelo construtor e usuário. Acrescente-se que o cálculo para a vida útil estimada (VUE) das construções leva em consideração o envelhecimento natural dos componentes dos sistemas construtivos, mas não contempla o efeito dos danos provocados pela entrada em operação e uso da edificação ou ausência de manutenção. Além disso, a ABNT NBR 5674:2012 - Manutenção de edificações Requisitos para o sistema de gestão de manutenção, indica quais os sistemas e serviços devem passar pelo processo de manutenção e em qual período, possibilitando a gestão da manutenção com qualidade. Entretanto, não é sempre o que ocorre nas edificações após a entrada em operação e uso. Na pesquisa, procurou-se, então, verificar qual a relação entre a vida útil estimada e os prazos de garantia das obras. Para medir a diferença percentual entre a VUP e a VUE, após a intervenção da ATPO foi utilizado o método dos fatores previsto na ISO 15.686:2000 - Building and construction assets service life planning e recomendado pela NBR 15.575-1:2013. As informações analisadas foram cedidas por uma construtora atuante na cidade do Recife, coletadas de um banco de dados proveniente da assistência técnica pós-obra (ATPO) de oito empreendimentos construídos na Região Metropolitana do Recife. A frequência de ocorrência de danos nas edificações foi analisada através da determinação da taxa de falhas dos empreendimentos. Os resultados assinalam para um percentual de redução da vida útil de projeto (VUP), da ordem de 20% da vida útil de referência (VUR), valores adotados da NBR 15.575:2013; apontam também, para uma concentração de avarias no estágio inicial da construção, acima de 50%, que correlacionando com a curva de probabilidade condicional de falha (curva da banheira) obtém-se um alto índice de falha brusca, classificando a edificação na fase da mortalidade infantil. Esses resultados refletem uma variação não planejada do nível de desempenho proposto para a edificação. Diante desse contexto, sugere-se vincular o prazo de garantia da obra com o nível de desempenho efetivo da construção. A aplicação de conceitos de confiabilidade permite inferir sobre os prazos de garantia da obra e fazer comparações com o valor previsto no aparato legal brasileiro.
14

Avaliação das emissões conduzidas e radiadas geradas por unidade eletrocirúrgica e sistema de iluminação com lâmpadas fluorescentes em equipamentos médicos

Moraes, Fábio Brignol de 16 December 2013 (has links)
Este trabalho apresenta um estudo sobre interferência eletromagnética, emissões radiada e conduzida, gerados pelo sistema de iluminação e pela unidade de eletrocirurgia (bisturi eletrônico) numa sala cirúrgica de um hospital da cidade de Pato Branco/PR. O trabalho consistiu em medidas de emissões conduzidas e radiadas de sistemas de iluminação fluorescentes em laboratório e de emissões conduzidas e radiadas “in loco” da unidade de eletrocirurgia. Além disso, foi feito estudo de referenciais sobre as normas, nacionais e internacionais, que incidem sobre estes dois sistemas. Como resultado do trabalho tem-se um panorama sobre a situação das emissões conduzidas e radiadas, pelos sistemas de iluminação fluorescente e unidade eletrocirúrgica utilizados no hospital. / This work presents a study on electromagnetic interference radiated and conducted emissions generated by the lighting system and the electrosurgery unit (eletric scalpel) in na operating room of a hospital in Pato Branco / PR. The work consisted of measurements of conducted and radiated emission of fluorescent lighting systems in the laboratory of conducted and radiated “in loco” electrosurgery unit emissions. Futhermore, a study was made of references on standarts, national and international, that focus on these two systems. Because of the work, has an overview on the situation of conducted and radiated emissions, the fluorecent lighting used in electrosurgical unit and hospital systems.
15

Dimensionamento à punção em apoios internos de lajes protendidas sem aderência

Leite Júnior, José Carlos Cirino 14 August 2015 (has links)
Submitted by Morgana Andrade (morgana.andrade@ufes.br) on 2016-03-22T19:49:43Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) jose carlos cirino leite junior.pdf: 4435177 bytes, checksum: 8e8f6eb9e0f91d4f07653b556647e567 (MD5) / Approved for entry into archive by Patricia Barros (patricia.barros@ufes.br) on 2016-03-23T15:31:40Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) jose carlos cirino leite junior.pdf: 4435177 bytes, checksum: 8e8f6eb9e0f91d4f07653b556647e567 (MD5) / Made available in DSpace on 2016-03-23T15:31:40Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) jose carlos cirino leite junior.pdf: 4435177 bytes, checksum: 8e8f6eb9e0f91d4f07653b556647e567 (MD5) / Esta dissertação trata da punção em lajes protendidas com cordoalhas não aderentes, para pilares internos, calculadas através das normas ABNT NBR 6118:2007, ABNT NBR 6118:2014, EN 1992-1-1:2004 e ACI 318-11. Ao longo do trabalho, são apresentados dimensionamentos à punção através desses códigos a fim de se obter uma análise comparativa dos resultados. Além disso, são expostas três situações de provas de carga não destrutivas para punção, realizadas em lajes reais. Os casos, verificados a partir da comparação entre as quatro normas, servem de base para avaliações sobre o nível de segurança estrutural entre os dimensionamentos. Após as análises teóricas, conclui-se que, no geral, o EC2:2004 e a NBR 6118:2014 são os códigos que geram os resultados menos conservadores no cálculo das armaduras de punção. Já o ACI 318-11 e a NBR 6118:2007 obtêm os resultados mais conservadores para esse dimensionamento. Quando considerados os carregamentos máximos sem utilização de armadura de punção, a norma americana se destaca, obtendo valores comparáveis aos do EC2:2004 e da NBR 6118:2014. A NBR 6118:2007 resulta em dimensionamentos sempre mais conservadores. / This work studies the punching shear in prestressed slabs with unbonded tendons, for internal columns, calculated by ABNT NBR 6118:2007, ABNT NBR 6118:2014, EN 1992-1-1:2004 and ACI 318-11. Punching shear calculations will be presented in order to obtain comparative results analysis. Also, there are three situations presented of non-destructive load tests for punching shear, in real slabs. The cases, calculated using the four compared regulation codes, provide a basis for assessments of the conservatism level among the formulations. After the theoretical analysis, in general, it is concluded that EC2:2004 and NBR 6118:2014 are the codes that generate less conservative results in punching shear calculation. However, ACI 318-11 and the NBR 6118:2007 obtain the most conservative results for this design. Considering the maximum loads without the use of punching shear reinforcement ACI 318 generates values comparable to EC2 and NBR 6118:2014. The most conservative results are always generated by NBR 6118:2007.
16

Gestão de segurança do trabalho na construção civil: a manutenção predial em uma indústria de alimentos

Makishima, José Narumi de Queiroz 28 November 2011 (has links)
As organizações têm repassado para empresas especializadas os trabalhos que originalmente realizavam com empregados de seus quadros de efetivos. Este fenômeno tem provocado um crescente movimento de subcontratação de serviços conhecido como terceirização. As empresas terceirizadas têm se estabelecido de forma frágil do ponto de vista da segurança do trabalho, negligenciando os aspectos mais básicos estabelecidos pela legislação vigente, normas técnicas e as boas práticas nesta área no intuito de oferecer propostas mais econômicas para fazer frente a um mercado cada vez mais competitivo. Estabeleceu-se como objetivo para esta pesquisa identificar as práticas adotadas em matéria de segurança por uma companhia multinacional do ramo de alimentos, que é certificada na Norma OHSAS 18.001:2007, no que tange as empresas terceirizadas que prestaram serviços de manutenção predial com foco nas atividades de construção civil no período de julho de 2009 a junho de 2010. A metodologia utilizada consistiu de um estudo detalhado da documentação relativa ao sistema de gestão da organização contratante quanto aos trabalhos terceirizados e dos registros das subcontratadas concernentes a acidentes e medidas prevencionistas adotadas para o atendimento das exigências estipuladas pela contratante. Como resultado principal desta pesquisa identificou-se que dentre as medidas adotadas destacaram-se o estabelecimento de processos administrativos e técnicos, como a operacionalização de ações chaves como a fundamentação dos trabalhos com base em requisitos da Norma OHSAS 18.001, dos programas de treinamento, do atendimento a legislação, da definição de procedimentos para atividades administrativas e de risco, de uma boa relação entre contratante e contratada, da organização de profissionais de segurança, de preparação de emergências e atendimento médico. Como conclusão verificou-se que as medidas implantadas foram eficazes, pois contribuíram efetivamente para que a área de manutenção predial com foco em construção civil apresentasse o melhor desempenho em termos de indicadores de acidentabilidade. Desta forma recomenda-se considerar a aplicação das ações preventivas identificadas nesta pesquisa em virtude da sua eficácia, e pelo processo de implantação ser basicamente de ordem administrativa. / Organizations have transferred to specialized companies that originally held the jobs of their employees with effective frameworks. This phenomenon has caused a growing movement known as outsourcing services. The outsourced companies have been established so fragile from the standpoint of safety at work, neglecting the most basic aspects established by the legislation, technical standards and best practice in this area in order to offer more economic proposals to deal with a market every increasingly competitive. It was established as a goal for this research to identify the practices adopted in terms of safety by a multinational company in the food industry field that is certified under OHSAS 18.001:2007, regarding outside contractors who provide building maintenance services with focus on civil construction activities during July 2009 thru June 2010. The methodology consisted of a detailed study relating to the contracting organization management system concerning outside contractors as well as of the records of accidents and preventive measures adopted to meet the requirements stipulated by the contractor. As a main result of this research it was identified that among the measures adopted, it were highlighted the establishment of administrative and technical procedures, such as the operationalization of key actions like work oriented on the requirements of OHSAS 18001, training programs, the legislation attendance, the definition of administration procedures and for risk management activities, a good relationship between the contractor and subcontractors, the organization of safety professionals, emergency preparedness and medical care. As conclusion it was found that the measures implemented were effective because they contributed to the branch of building maintenance with a focus on civil construction on presenting the best performance in terms of accident rates. Therefore it is recommended to consider the application of the preventive actions identified in this survey due to its effectiveness, and for the fact that the deployment process is basically administrative.
17

Avaliação das emissões conduzidas e radiadas geradas por unidade eletrocirúrgica e sistema de iluminação com lâmpadas fluorescentes em equipamentos médicos

Moraes, Fábio Brignol de 16 December 2013 (has links)
Este trabalho apresenta um estudo sobre interferência eletromagnética, emissões radiada e conduzida, gerados pelo sistema de iluminação e pela unidade de eletrocirurgia (bisturi eletrônico) numa sala cirúrgica de um hospital da cidade de Pato Branco/PR. O trabalho consistiu em medidas de emissões conduzidas e radiadas de sistemas de iluminação fluorescentes em laboratório e de emissões conduzidas e radiadas “in loco” da unidade de eletrocirurgia. Além disso, foi feito estudo de referenciais sobre as normas, nacionais e internacionais, que incidem sobre estes dois sistemas. Como resultado do trabalho tem-se um panorama sobre a situação das emissões conduzidas e radiadas, pelos sistemas de iluminação fluorescente e unidade eletrocirúrgica utilizados no hospital. / This work presents a study on electromagnetic interference radiated and conducted emissions generated by the lighting system and the electrosurgery unit (eletric scalpel) in na operating room of a hospital in Pato Branco / PR. The work consisted of measurements of conducted and radiated emission of fluorescent lighting systems in the laboratory of conducted and radiated “in loco” electrosurgery unit emissions. Futhermore, a study was made of references on standarts, national and international, that focus on these two systems. Because of the work, has an overview on the situation of conducted and radiated emissions, the fluorecent lighting used in electrosurgical unit and hospital systems.
18

Aplicação da norma IEC 61400-25 na automação e controle de parques eólicos no Brasil

Celino, Ronaldo Andrusyszyn 07 February 2014 (has links)
The goal of this project is to develop a system of supervision, communication and control, implemented in a free supervisory software the SCADABR for installed wind farms and/or to be installed in Brazil, from the considerations and recommendations of IEC 61400 - 25. The construction of complete wind farms with full automation, has led entrepreneurs to focus their efforts not only on profit and productivity, but also in: human capital, concerned with the management system, technological mastery and communication at all levels. Information processing with communication, opened borders with new forms of relationship and growing trend in the industrial automation field, which favors different devices to communicate with others in a cooperative way. However, the largest manufacturers of wind generation plants still offer proprietary solutions "black boxes" for the networks field, which results in a variety of protocols of systems, causing the client the full dependence on these suppliers. Aiming interoperability and flexibility of operation, groups of researchers advocate standards of open model, as the solution of networks and protocols for all, leaving customers free. In this struggle, the best-known organization in the field of wind energy is IEC 61400-25, specifically for the monitoring system and free communication among different equipment vendors, nevertheless internal communication of the components of wind power plant is not within the standard. The application range of the standard covers the operation of this kind of wind farm, including wind turbine, meteorological measurement system, electrical system and management system, but does not include the relevant line of the substation feeding and information. Hence, the interaction with the supervisory system SCADABR developed in "open-source" model of free license. It is proposed the application of a multi-platform Java-based, from an application server, like Apache Tomcat the standard choice. Considering the requirements of the present communication model in IEC 61400-25-2 it is defined a model of information for monitoring and control of wind power plants, to this end, part-data simulator MatrikonOPC through customer / OPC DA server interaction (Object Linking and Embedding for Process Control Data Access), with ScadaBR software. / O objetivo da pesquisa é desenvolver um sistema de supervisão, comunicação e controle, implementado em um software de supervisão livre o ScadaBR, para parques eólicos instalados e/ou a serem instalados no Brasil, a partir das considerações e recomendações da norma IEC 61400-25. A construção de parques eólicos completos, com automação total, tem levado os empreendedores a focalizar seus esforços não só no lucro e produtividade, mas também no: capital humano, preocupando-se com o sistema de gestão, domínio tecnológico e comunicação em todos os níveis. O processamento da informação com a comunicação, abriu fronteiras com as novas formas de relacionamento e a crescente tendência na área de automação industrial, favorece que diferentes dispositivos comuniquem-se com outros de uma maneira cooperativa. No entanto, os maiores fabricantes de usinas de geração eólica ainda oferecem soluções proprietárias caixas pretas para as redes de campo, o que resulta numa diversidade de protocolos de sistemas, levando dependência desses fornecedores. Visando a interoperabilidade e flexibilidade de operação, grupos de pesquisadores defendem normas de padrão aberto, como a solução de redes e protocolos para todos, deixando os clientes livres. Nesta luta, a organização mais conhecida na área de energia eólica é a norma IEC 61400-25, especificamente para o sistema de monitoramento e comunicação livre entre diferentes fornecedores de equipamentos, porém a comunicação interna dos componentes da usina de energia eólica não está no âmbito desta norma. A faixa de aplicação da norma abrange parte da operação desse tipo de usina, incluindo turbina de vento, sistema de medição meteorológica, sistema elétrico e sistema de gestão, mas não inclui a linha relevante de alimentação e informação da subestação. Daí a interação com o sistema supervisório ScadaBR, desenvolvido em modelo open-source de licença gratuita. Propõe-se a aplicação de uma multi-plataforma baseada em Java, a partir de um servidor de aplicações, com o Apache Tomcat a escolha padrão. Considerando as exigências do modelo de comunicação presentes na Norma IEC 61400-25-2, define-se um modelo de informação para monitoramento e controle de usinas eólicas, para tal, parte-se do simulador de dados MatrikonOPC, por meio da interação cliente / servidor OPC DA (Object Linkingand Embedding for Process Control Data Access), com o software ScadaBR.
19

Aplicação da norma IEC 61400-25 na automação e controle de parques eólicos no Brasil

Celino, Ronaldo Andrusyszyn 07 February 2014 (has links)
The goal of this project is to develop a system of supervision, communication and control, implemented in a free supervisory software the SCADABR for installed wind farms and/or to be installed in Brazil, from the considerations and recommendations of IEC 61400 - 25. The construction of complete wind farms with full automation, has led entrepreneurs to focus their efforts not only on profit and productivity, but also in: human capital, concerned with the management system, technological mastery and communication at all levels. Information processing with communication, opened borders with new forms of relationship and growing trend in the industrial automation field, which favors different devices to communicate with others in a cooperative way. However, the largest manufacturers of wind generation plants still offer proprietary solutions "black boxes" for the networks field, which results in a variety of protocols of systems, causing the client the full dependence on these suppliers. Aiming interoperability and flexibility of operation, groups of researchers advocate standards of open model, as the solution of networks and protocols for all, leaving customers free. In this struggle, the best-known organization in the field of wind energy is IEC 61400-25, specifically for the monitoring system and free communication among different equipment vendors, nevertheless internal communication of the components of wind power plant is not within the standard. The application range of the standard covers the operation of this kind of wind farm, including wind turbine, meteorological measurement system, electrical system and management system, but does not include the relevant line of the substation feeding and information. Hence, the interaction with the supervisory system SCADABR developed in "open-source" model of free license. It is proposed the application of a multi-platform Java-based, from an application server, like Apache Tomcat the standard choice. Considering the requirements of the present communication model in IEC 61400-25-2 it is defined a model of information for monitoring and control of wind power plants, to this end, part-data simulator MatrikonOPC through customer / OPC DA server interaction (Object Linking and Embedding for Process Control Data Access), with ScadaBR software. / O objetivo da pesquisa é desenvolver um sistema de supervisão, comunicação e controle, implementado em um software de supervisão livre o ScadaBR, para parques eólicos instalados e/ou a serem instalados no Brasil, a partir das considerações e recomendações da norma IEC 61400-25. A construção de parques eólicos completos, com automação total, tem levado os empreendedores a focalizar seus esforços não só no lucro e produtividade, mas também no: capital humano, preocupando-se com o sistema de gestão, domínio tecnológico e comunicação em todos os níveis. O processamento da informação com a comunicação, abriu fronteiras com as novas formas de relacionamento e a crescente tendência na área de automação industrial, favorece que diferentes dispositivos comuniquem-se com outros de uma maneira cooperativa. No entanto, os maiores fabricantes de usinas de geração eólica ainda oferecem soluções proprietárias caixas pretas para as redes de campo, o que resulta numa diversidade de protocolos de sistemas, levando dependência desses fornecedores. Visando a interoperabilidade e flexibilidade de operação, grupos de pesquisadores defendem normas de padrão aberto, como a solução de redes e protocolos para todos, deixando os clientes livres. Nesta luta, a organização mais conhecida na área de energia eólica é a norma IEC 61400-25, especificamente para o sistema de monitoramento e comunicação livre entre diferentes fornecedores de equipamentos, porém a comunicação interna dos componentes da usina de energia eólica não está no âmbito desta norma. A faixa de aplicação da norma abrange parte da operação desse tipo de usina, incluindo turbina de vento, sistema de medição meteorológica, sistema elétrico e sistema de gestão, mas não inclui a linha relevante de alimentação e informação da subestação. Daí a interação com o sistema supervisório ScadaBR, desenvolvido em modelo open-source de licença gratuita. Propõe-se a aplicação de uma multi-plataforma baseada em Java, a partir de um servidor de aplicações, com o Apache Tomcat a escolha padrão. Considerando as exigências do modelo de comunicação presentes na Norma IEC 61400-25-2, define-se um modelo de informação para monitoramento e controle de usinas eólicas, para tal, parte-se do simulador de dados MatrikonOPC, por meio da interação cliente / servidor OPC DA (Object Linkingand Embedding for Process Control Data Access), com o software ScadaBR.

Page generated in 0.0899 seconds