• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 83
  • Tagged with
  • 83
  • 83
  • 81
  • 81
  • 80
  • 22
  • 20
  • 18
  • 16
  • 15
  • 14
  • 10
  • 9
  • 9
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

AVALIAÇÃO CEFALOMÉTRICA DA ESTABILIDADE PÓS-EXPANSÃO RÁPIDA DA MAXILA ASSISTIDA CIRURGICAMENTE / Cephalometric evaluation of the stability post rapid maxillary expansion surgically assisted

Scattaregi, Pedro Luis 20 February 2008 (has links)
Made available in DSpace on 2016-08-03T16:31:10Z (GMT). No. of bitstreams: 1 02 - Revisao da Literatura.pdf: 52833 bytes, checksum: d0497a36eff0b91592a9fdc38ed827b8 (MD5) Previous issue date: 2008-02-20 / This study evaluated the stability of the dental and skeletal changes produced by Rapid Maxillary Expansion Surgically Assisted (RMESA), in transversal and vertical dimensions. The sample selected for this retrospective study comprised 60 posteroanterior cephalograms, of 15 patients, being 6 males and 9 females, with mean age of 23,3 years old. An Hyrax appliance was used and the surgical procedure was caractherized by median sagitall osteotomy and non approach of pterygopalatine suture. The beginning of activation occurred in the third post-operatory day, being that, the limits for the expansion were determined by criteria eminently clinical. All the patients were radiografied in periods preexpansion (T1), immediate post-expansion (T2), three months post-expansion (with the Hyrax appliance as retention) (T3) and six months post-expansion (with the removable acrylic plate as retention) (T4). Linear measurments were obtained from the cephalograms tracings generated by a computerized program (Radiocef Studio 2) and statistically analized by the test of variance (ANOVA) and Tukey at the level of 5% of significance. It was concluded that RMESA produced a statistically significant increase , of nasal cavity, maxillary width , upper intermolars distance, from T1 to T2, and were mantained in T3 and T4. The facial width and the lower intermolars distance did not presented changes after the RMESA. Evaluating the vertical behavior of the face, it was observed an increase of anterior inferior facial heigh in periods T1 to T2 that decreased after retention of three months (T3) and mantained stable in T4, although increased if compared with T1.(AU) / Este estudo avaliou a estabilidade das alterações dentárias e esqueléticas produzidas pela Expansão Rápida da Maxila Assistida Cirurgicamente (ERMAC), no sentido transversal e vertical. A amostra selecionada para este estudo retrospectivo foi composta de 60 telerradiografias em norma frontal, de 15 pacientes, sendo 6 do sexo masculino e 9 do sexo feminino, com média de idade de 23 anos e 3 meses. Utilizou-se o disjuntor tipo Hyrax e o procedimento cirúrgico foi caracterizado pela osteotomia sagital mediana da maxila e não abordagem da sutura pterigopalatina. O início da ativação ocorreu no terceiro dia pós-operatório, sendo que, os limites para a expansão foram determinados por critérios eminentemente clínicos. Todos os pacientes foram radiografados nas fases pré-expansão (T1), pós-expansão imediata (T2), 3 meses pós- expansão (com o próprio disjuntor como contenção) (T3) e 6 meses pós-expansão (com a placa de acrílico removível como contenção) (T4). Medidas lineares foram obtidas a partir dos traçados cefalométricos gerados por um programa computadorizado (Radiocef Studio 2) e analisadas estatisticamente pelo teste de variância (ANOVA) e Tukey ao nível de 5% de significância. Concluiu-se que a ERMAC produziu um aumento estatisticamente significante, da cavidade nasal, largura maxilar, distância intermolares superiores, de T1 para T2, e que se mantiveram em T3 e T4. A largura facial e as distâncias intermolares inferiores não apresentaram alterações após a ERMAC. Avaliando o comportamento vertical da face, notou-se um aumento da AFAI nos tempos T1 para T2 que, diminuiu após a contenção de 3 meses (T3) e permaneceu estável em T4, embora aumentada se comparada com T1.(AU)
42

Avaliação das inclinações dentárias obtidas no tratamento ortodôntico com bráquetes autoligados utilizando tomografia computadorizada / Evaluation of dental tipping achieved in orthodontic treatment with self-ligating brackets using computed tomography images

Araújo, Cláudia Cristina Machado 21 February 2008 (has links)
Made available in DSpace on 2016-08-03T16:31:10Z (GMT). No. of bitstreams: 1 Claudia Cristina Machado Araujo.pdf: 1749823 bytes, checksum: 852b1e86d0d876a34bf8326c51c8f185 (MD5) Previous issue date: 2008-02-21 / This research had the purpose of evaluating the changes in dental tipping of the anterior teeth of patients treated with self-ligating brackets orthodontic appliances, using computed tomography images. It has been selected a 10-patient clinical sample, all of them presenting complete permanent dentition, either a class I, II or III malocclusion and a 4 mm maximum crowding of the anterior teeth. All patients underwent a non extraction treatment in the post-graduate Orthodontic clinics at Universidade Metodista de São Paulo, using Damon 2 self-ligating brackets standard prescription by ORMCO . The anterior teeth inclinations (from canine to canine) have been assessed in both upper and lower arches, using tomographic images generated by a NewTom volumetric computed tomograph model DVT 9000 (developed by NIM, Verona, Italy), obtained in two distinct stages, i.e. before the orthodontic treatment (referred as T1), and at the end of the treatment, after insertion of a 0,019 x 0,025 stainless leveling wires (referred as T2), respectively. It s been also used the QR-DVT 9000 software and its secondary working station tools as an aid device to accomplish the measuring. The data analysis showed a remarkable increase of the inclinations of the upper canines and lateral incisors, as well as of the lower central and lateral incisors, as compared to the inclinations values indicated in the prescription used in the study, suggesting the 0,019 x 0,025 stainless steel wire inability to reproduce its torque values.(AU) / O objetivo deste trabalho foi analisar a expressão dos torques dentários em pacientes tratados com aparelhos ortodônticos fixos com bráquetes autoligados, utilizando tomografias computadorizadas. Para este estudo, foi selecionada uma amostra clínica de 10 pacientes, seguindo como critérios de inclusão, indivíduos que apresentavam dentição permanente e todos os dentes presentes, com apinhamento superior ou igual a 4 mm, tratados sem extração. Todos os pacientes foram tratados na clínica da pós-graduação em Ortodontia da Universidade Metodista de São Paulo, utilizando-se bráquetes autoligados Damon 2 ORMCO na prescrição padrão. Foram realizadas medições das inclinações dos dentes anteriores, de canino a canino, superiores e inferiores, realizadas por meio de imagens tomográficas obtidas em um tomógrafo computadorizado volumétrico NewTom, em seu modelo DVT-9000 (NIM Verona - Itália), obtidas em dois tempos: antes do início do tratamento ortodôntico (denominado de T1) e depois do tratamento ortodôntico, após a inserção do último fio de nivelamento, de calibre 0,019 x 0,025 de aço inoxidável(denominado de T2). Para auxílio destas mensurações, foi utilizado o software QR-DVT 9000 e após análise dos resultados foram aplicados testes estatíscos (testes "t" pareado e Dalberg) e observou-se que as inclinações dos dentes do segmento anterior aumentaram, principalmente, nos caninos e incisivos laterais superiores, incisivos centrais e laterais inferiores. Os dentes apresentaram valores de inclinação diferentes da prescrição, tanto no início quanto no final do tratamento, denotando a incapacidade do fio 0,019 x 0,025 de aço inoxidável em reproduzir os torques indicados na prescrição padrão utilizada neste presente estudo.(AU)
43

ESTUDO COMPARATIVO DAS ANGULAÇÕES E TORQUES DE BRAQUETES DE DIFERENTES MARCAS COMERCIAIS / Comparative study of angulation and inclination of different brackets trademarks

Zanesco, Alexandre 27 April 2008 (has links)
Made available in DSpace on 2016-08-03T16:31:12Z (GMT). No. of bitstreams: 1 Alexandre Zanesco.pdf: 1035848 bytes, checksum: d02024f61764f0328225b9a073241130 (MD5) Previous issue date: 2008-04-27 / The purpose of this study was to compare the angulations and torques of orthodontic brackets from different trademarks in relation to the Roth s prescription and also in relation with the recommended values from the manufacturer. It was used 150 orthodontic metalic stainless steel brackets, from upper cuspid and incisors in its prescription and evaluated through a vertical Benchtop Measuring Projector in the Metrology laboratory of Dental Morelli Ltda. After collecting the results and the application of statistical test, it was obtained that values of torque found with the Roth´s prescription was similar between the manufacturer and the cuspid angulation has been shown higher values in comparison to that proposed from the author in the manufacturer Morelli, and for the teeth 2.1 and 2.2, the increased angulation was showed on Abzil manufacturer s bracket. On comparative values of torque obtained within all manufacturers, Unitek showed greater reliability in torque values than others. For angulation, the reliability of the same manufacture was not superious when compared to the other manufacturers. It was concluded that the differences on both torque and angulation to the author values and prescription of the manufacturers studies fall within the degree of advocated tolerance by a German association of orthodontic accessories. / O objetivo deste estudo foi comparar as angulações e torques de braquetes de marcas comerciais distintas em relação à prescrição de Roth e também em relação aos valores preconizados pelo fabricante. Foram utilizados 150 braquetes metálicos de aço inoxidável, de caninos e incisivos superiores na respectiva prescrição, avaliadas por meio de um perfilômetro. Após a coleta dos dados e aplicação do tratamento estatístico, os resultados demonstraram que os valores de torque obtidos com a prescrição de Roth foram semelhantes entre os fabricantes. Na angulação, os caninos superiores apresentaram valores acima do proposto pelo autor para o fabricante Morelli, e para os dentes 21 e 22, a angulação foi maior para o fabricante Abzil. Na comparação dos valores de torque obtidos com os valores recomendados pelos fabricantes, a Unitek demonstrou maior fidedignidade no torque comparada às demais marcas. Conclui-se que as diferenças tanto de torque quanto de angulação quando comparados aos valores do autor e à prescrição dos fabricantes, se enquadram dentro de um grau de tolerância preconizada por um órgão regulador de peças ortodônticas alemãs.
44

Avaliação das inclinações dentárias obtidas pela técnica Straight-Wire Prescrição Capelozza Classe II.

Fattori, Liana 08 March 2006 (has links)
Made available in DSpace on 2016-08-03T16:31:12Z (GMT). No. of bitstreams: 1 Liana Fattori.pdf: 2061187 bytes, checksum: 58f918c462dde751cd1b9fb02368aa94 (MD5) Previous issue date: 2006-03-08 / Ao criar a técnica para tratamento ortodôntico denominado Straight-Wire, Andrews introduziu o uso de bráquetes pré-programados, ou bráquetes construídos individualmente para cada dente, com o objetivo de melhor posicioná-los ao final do tratamento. Capelozza Filho sugeriu novas angulações e inclinações para dentes que necessitavam de ajuste ao final do tratamento, criando prescrições para os diferentes padrões faciais. O presente trabalho tem por objetivo avaliar as alterações nas inclinações dentárias causadas pelo tratamento ortodôntico nos dentes anteriores utilizando-se da prescrição Capelozza Classe II. Foram selecionados 17 indivíduos adultos de padrão facial II, portadores de má-oclusão Classe II; para tratamento ortodôntico compensatório, e em três tempos clínicos, relativos a três diferentes fios ortodônticos (.020 ; .019 x .025 , .021 x .025 ), foram realizados exames de tomografia computadorizada volumétrica, para mensuração e posterior avaliação das inclinações dentárias alcançadas em cada um dos tempos, pela ação de cada um dos fios, comparando-se estes valores aos da prescrição utilizada, bem como das diferenças ocorridas entre os tempos. Após a coleta de dados e aplicação dos testes estatísticos, concluiu-se que existe diferença estatística (p<0,05) na maioria dos valores da prescrição e os valores encontrados em cada um dos tempos avaliados; não foram encontradas diferenças estatisticamente significantes quando comparados os tempos estudados. Observou-se também uma tendência dos dentes a expressarem a prescrição apenas em T3.
45

AVALIAÇÃO DA REPRODUTIBILIDADE DE PONTOS CEFALOMÉTRICOS NAS TELERRADIOGRAFIAS DIGITAIS EM NORMA LATERAL NOS FORMATOS DICOM, TIFF E JPEG / Evaluation the reproducibility of cephalometric landmarks on digital lateral headfilms at the file formats DICOM, TIFF and JPEG

Falcão, Livia Maria Rocha 26 March 2009 (has links)
Made available in DSpace on 2016-08-03T16:31:13Z (GMT). No. of bitstreams: 1 Livia Maria.pdf: 2258638 bytes, checksum: 3131cd2061c06afb853c81d96d50af92 (MD5) Previous issue date: 2009-03-26 / The digital radiography image acquired by the photostimulable storage phosphor plates system normally is showed in the computer screen as a DICOM format, characterized for the high resolution of the images. As this format uses a lot of memory space for storage, the digital images are submitted to a compression, which optimizes the capacity of space on the computers and reduces the time of transmission for the Internet. The aim of this study was to evaluate the effect of TIFF and JPEG compression in the intraobserver and interobserver reproducibility of the cephalometric landmarks identification on lateral headfilms compared with DICOM format. The sample consisted of 90 digital lateral cephalometric images obtained from 30 individuals, in DICOM format. These images were converted for formats JPEG, with Quality Factor 80 and TIFF. After blind and random the sample, three observers, orthodontists, were calibrated and ask to identify 15 cephalometric landmarks in each image using x and y coordinates system. The results had shown that the cephalometric landmarks identification had presented agreement of intraobserver and interobserver reproducibility, except for the points Go, Po, Or, B and Pog'. The statistic analyze showed no difference between the file formats for each point and axis. JPEG and TIFF compressions studied had not effect in the intraobserver and interobserver reproducibility of the cephalometric landmarks identification on digital lateral headfilm.(AU) / A imagem radiográfica digital adquirida pelo sistema de placa de fósforo foto ativada é normalmente visualizada no monitor do computador no formato DICOM, caracterizado pela alta resolução das imagens. Como este formato ocupa muito espaço para armazenamento, as imagens digitais são submetidas a uma compressão, que otimiza a capacidade de espaço dos computadores e reduz o tempo de transmissão pela Internet. O objetivo desse estudo foi avaliar a influência da compressão TIFF e JPEG na reprodutibilidade intra e interexaminador da marcação de pontos cefalométricos em imagens de telerradiografias em norma lateral comparadas com o formato DICOM. A amostra consistiu de 90 imagens de telerradiografias obtidas a partir de 30 indivíduos, dos quais se obteve uma radiografia digital exibida no formato DICOM. Estas imagens foram convertidas para os formatos JPEG, com Fator de Qualidade 80 e TIFF. Após o cegamento e randomização da amostra, três ortodontistas calibrados marcaram a localização de 15 pontos cefalométricos em cada imagem utilizando o sistema de coordenadas x e y. Os resultados mostraram que as marcações dos pontos cefalométricos apresentaram concordância de reprodutibilidade tanto intra como interexaminador, exceto para os pontos Go, Po, Or, B e Pog . Os diferentes formatos de arquivo mostraram resultados estatisticamente semelhantes para cada ponto e eixo aferido. As compressões JPEG e TIFF estudadas não tiveram efeito, em imagens de telerradiografias em norma lateral, na reprodutibilidade intra e interexaminadores da marcação dos pontos cefalométricos testados.(AU)
46

COMPARAÇÃO DO ATRITO IN VITRO EM BRAQUETES ESTÉTICOS CONVENCIONAIS E AUTOLIGADOS / A comparison of in vitro friction forces among conventional and self-ligating aesthetic orthodontic brackets

Leal, Rodrigo Severo 25 March 2009 (has links)
Made available in DSpace on 2016-08-03T16:31:14Z (GMT). No. of bitstreams: 1 Paginas 1 a 110.pdf: 2675655 bytes, checksum: ebe1b48d56fd661d5dc8a8a84083c9f1 (MD5) Previous issue date: 2009-03-25 / The aim of this in vitro study was to compare the friction resistances among conventional steel-ligated and self-ligating aesthetic brackets with different retangular stainless steel archwires sizes at zero and three degrees angulation. 120 brackets of 6 commercial brands (Gemini, Clarity conventional, Transcend, Inspire, Clarity self-ligating, Damon self-ligating) where tested, 20 brackets of each brand. Two brackets were glued on a metallic plate, with angulations of zero and three degrees between them. Retangular stainless steel archwires of 0.017 x 0.025 , 0.019 x 0.025 and 0.021 x 0.025 were tested on a "instron" universal essay machine. Variance analisys and Tukey tests (p<0,05) were run to compare brackets with different archwires sizes and angulation. The study demonstrated that at zero degree angulation the self-ligating brackets produced less friction in relation to convencional ligated bracket in all archwires sizes tested. Clarity self-ligating produces even less friction then aesthetic Damon, except with the 0.021 x 0.025 archwire, where both self-ligating brackets produced statisticly similar results. Inspire bracket had the least friction with 0.019 x0.025 and 0.021 x0.025 . Similar results were observed for the self-ligating brackets in relation to convencionals at three degrees angulation. Among the convencional steel-ligated brackets, Gemini, Clarity, Transcend and Inspire produced the higest friction resistances, in increasing order. In conclusion, the angulation between the brackets increases significatively the friction forces. Furthermore, the self-ligating brackets produces less friction in relation to conventional ligating brackets, and the Clarity self-ligating bracket produced less friction than aesthetic Damon, except with 0.021 x 0.025 archwire size.(AU) / O objetivo do presente estudo consistiu em comparar in vitro o atrito produzido por braquetes estéticos, convencionais e autoligados quando inseridos fios retangulares de aço inoxidável de diferentes dimensões, nas angulações de zero e três graus entre os braquetes. Foram utilizados 120 braquetes de 6 marcas comerciais (Gemini, Clarity convencional, Transcend, Inspire, Clarity autoligado, Damon autoligado), sendo 20 braquetes de cada marca comercial. Para os ensaios laboratoriais, foram colados dois pares de braquetes de cada marca comercial em uma placa metálica, com uma angulação de zero e três graus entre os braquetes. Foram empregados os fios retangulares de aço inoxidável 0,017 x 0,025 , 0,019 x 0,025 e 0,021 x0,025 em uma máquina de ensaios universal Instron . Para a comparação entre os braquetes nos diferentes fios e angulações, foi utilizada a análise de variância e o teste de Tukey (p<0,05). Os resultados demonstraram que na angulação de zero grau, os braquetes autoligados apresentaram menor atrito em relação aos convencionais em todos os fios avaliados, sendo que, o braquete Clarity autoligado apresentou menor atrito estatisticamente significante que o Damon, exceto no fio 0,021 x 0,025 , em que ambos os braquetes autoligados apresentaram atrito estatisticamente semelhante. O braquete Inspire demonstrou o maior atrito em relação aos demais braquetes nos fios 0,019 x0,025 e 0,021 x0,025 . Na angulação de três graus, observou-se resultados semelhantes aos braquetes posicionados sem angulação comparando os braquetes autoligados em relação aos convencionais. Contudo, verificou-se que o atrito entre os braquetes convencionais ocorreu em ordem crescente sendo braquetes Gemini, Clarity convencional, Transcend e Inspire. Pôde-se concluir que a angulação entre os braquetes aumenta consideravelmente o atrito. Além disso, em ambas as angulações, os braquetes autoligados demonstraram menor atrito em relação aos convencionais, sendo que o braquete Clarity autoligado promoveu menor atrito que o Damon estético, exceto no fio 0,021 x 0,025 .(AU)
47

Avaliação do Índice de Maturação das Vértebras Cervicais em radiografias cefalométricas laterais, tomadas com diferentes posicionamentos de cabeça / Avaliação do Índice de Maturação das Vértebras Cervicais em radiografias cefalométricas laterais, tomadas com diferentes posicionamentos de cabeça

Yamazaki, Marcos Shinao 20 April 2010 (has links)
Made available in DSpace on 2016-08-03T16:31:14Z (GMT). No. of bitstreams: 1 CAPA.pdf: 39961 bytes, checksum: cf4605c3ea187328b828df9a9ace748e (MD5) Previous issue date: 2010-04-20 / This study aimed to evaluate the growth phase in a sample of 49 patients, with ages ranging from 9 to 15 years old, observing the cervical vertebrae on lateral radiographs taken in natural head position (NHP) and positioning errors, with head inclination up to 15° (NHP-High) and 15° down (NHP-Low), to define how important this is in the accuracy assessment phase of growth. The weighted kappa test showed a substantial degree of agreement between NHP and NHP High and between NHP and NHP-Low. Since the nonparametric test of wilcoxon (p <0.05) showed statistically significant difference between these comparisons. Thus, the NHP showed to be more reliable in assessing the cervical vertebrae maturation (CVM), furthermore the radiographs with positioning accuracy evaluated did not show statistically significant with the PNC.(AU) / Este trabalho teve como finalidade avaliar a fase de crescimento em uma amostra de 49 pacientes, com idades variando de 9 a 15 anos, observando as vértebras cervicais em radiografias laterais, tomadas na posição natural de cabeça (PNC) e com erros de posicionamento, com inclinações de cabeça de 15o para cima (PNC-Alta) e de 15 o para baixo (PNC-Baixa), visando definir o quão importante isto é na precisão da avaliação da fase de crescimento. O teste kappa ponderado mostrou um grau de concordância substancial entre PNC e PNC-Alta e entre PNC e PNC-Baixa. Já o teste não paramétrico de wilcoxon (p<0,05) mostrou diferença estatisticamente significante entre essas comparações. Desta forma, a PNC demonstrou ser mais confiável na avaliação do Índice de Maturação das Vértebras Cervicais (IMVC), porém as telerradiografias com erro de posicionamento avaliadas não tiveram um grau de discordância que indicasse sua não utilização na clínica para predição de crescimento.(AU)
48

Avaliação da reprodutibilidade da marcação de pontos cefalométricos na telerradiografia cefalométrica póstero-anterior digital nos formatos DICOM, JPEG e TIFF

Tassara, Luiz Felipe Rossi 15 April 2010 (has links)
Made available in DSpace on 2016-08-03T16:31:15Z (GMT). No. of bitstreams: 1 Luiz Felipe Rossi Tassara.pdf: 2423467 bytes, checksum: a93c786e4603fdb675dd48b24da6aefd (MD5) Previous issue date: 2010-04-15 / A terradiografia cetalométrica póstero-anterior digital está substituindo a telerradiografia convencional, porém permanece a dúvida se os erros de reprodutibilidade encontrados nas telerradiografias cefalométricas póstero-anteriores, também ocorreriam nas radiográfias digitais e se o formato de arquivo da imagem poderá influenciar na reprodutibilidade dos pontos cefalométricos. O objetivo deste estudo foi avaliar a reprodutibilidade da marcação de alguns pontos cefalométricas da análise cefalométrica de RICKETTS, em telerradiografias cefalométricas póstero-anteriores digitais, nos formatos DICOM, TIFF e JPEG. A amostra consistiu de 150 imagens digitais de terradiografias cefalométricas póstero-anteriores, obtidas a partir de 30 indivíduos, no formato DICOM; que foram convertidas para os formatos TIFF e JPEG nos fatores de qualidade 100, 80 e 60. Após o cegamento e randomização da amostra, três ortodontistas marcaram os pontos cefalométricos utilizando o sistema de coordenadas cartesianas, eixos x e y, no Programa Radiocef (Radio Memory) Para a análise estatística foram utilizados a Correlação Intraclasse, Fórmula de Dalhberg, Análise de Variância (ANOVA) e Análise de Comparações Multiplas de Bonferroni.(AU)
49

FATORES RELACIONADOS À PROPORÇÃO DENTAL ANTERIOR DE BOLTON EM INDIVÍDUOS COM OCLUSÃO NORMAL NATURAL / FATORES RELACIONADOS À PROPORÇÃO DENTAL ANTERIOR DE BOLTON EM INDIVÍDUOS COM OCLUSÃO NORMAL NATURAL / Factors related to Bolton s anterior ratio in Brazilians with natural normal occlusion / Factors related to Bolton s anterior ratio in Brazilians with natural normal occlusion

Jóias, Renata Pilli 25 March 2010 (has links)
Made available in DSpace on 2016-08-03T16:31:15Z (GMT). No. of bitstreams: 1 Paginas 1-43.pdf: 4925935 bytes, checksum: 290160b606f5978346daa511574f6a06 (MD5) Previous issue date: 2010-03-25 / The Bolton anterior ratio should be considered in the orthodontic planning in order to excellent occlusion achievement. The aim of this study was to verify wether some factors could be related to Bolton s anterior ratio: upper incisors buccolingual thickness, upper incisors mesiodistal tipping, overjet and overbite, and if there is sexual dimorfism. Thirty-five pairs of dental casts with natural normal occlusion had been evaluated, proceeding from 27 females and 8 male Caucasoid individuals, aged between 13 years old and 17 years and 4 months (mean age: 15 years and 8 months). A digital caliper and a piece of ruler were used for attainment of the measures. The anterior ratio was 77,48% (SD±2,22), showing to be statistically similar to Bolton s, 77,20%, SD±1,65. Based on Pearson s test, just the overbite showed to be related to the anterior ratio. It was not found sexual dimorfism.(AU) / A proporção anterior do tamanho dental de Bolton deve ser considerada no planejamento do caso quando se almeja uma oclusão ótima na finalização do tratamento ortodôntico. Este estudo teve por objetivo verificar se há relação entre as seguintes variáveis e a proporção anterior de Bolton: espessura vestíbulo-lingual dos incisivos superiores, relação entre a angulação dental dos incisivos superiores e o espaço mesiodistal por eles ocupado, sobressaliência e sobremordida, e se há dimorfismo sexual. Foram avaliados 35 pares de modelos em gesso com oclusão normal natural, provenientes de 27 indivíduos do sexo feminino e 8 do masculino, leucodermas, com idade entre 13 anos e 17 anos e 4 meses (idade média: 15 anos e 8 meses). Utilizou-se um paquímetro digital e um fragmento de régua para a obtenção das medidas. A proporção anterior encontrada foi de 77,48% (DP±2,22), estatisticamente semelhante ao valor proposto por Bolton, 77,20% (DP±1,65). De acordo com o teste de Pearson, somente a sobremordida mostrou relação estatisticamente significante com a proporção dental anterior. Não foi observado dimorfismo sexual.(AU)
50

O tratamento ortod?ntico em uma perspectiva a longo prazo: avalia??o da estabilidade oclusal e do grau de satisfa??o dos pacientes

Maia, Nair Galv?o 28 February 2011 (has links)
Made available in DSpace on 2014-12-17T14:13:44Z (GMT). No. of bitstreams: 1 NairGM_TESE.pdf: 781823 bytes, checksum: 1ac17cba137a9e5abbbe15147eaca5f1 (MD5) Previous issue date: 2011-02-28 / This study aimed to evaluate factors associated to orthodontic treatment stability and patient satisfaction in the long-term. A total of 209 patients (88 class I and 121 class II) treated with straight wire fixed appliance were selected at least 5 years post treatment. Six hundred twenty seven dental casts were examined with the PAR Index at pretreatment (T1), end of treatment (T2), and at long-term follow up (T3, mean 8.5 years post treatment). At T3, a Dental Impact on Daily Living questionnaire was used to assess patient satisfaction with the dentition in the long-term. Friedman test and multiple regression analysis were used to evaluate changes among the time points and factors associated with stability and patient satisfaction. Predictive factors used to exam the occlusion were: PAR Index at T1 and T2, age at T1, the amount of time without retainer, length of Hawley retainer wear, length of follow-up, sex, extraction and third molar status. To assess patient satisfaction were considered: changes produced by the orthodontic treatment (PAR T2-T1), post treatment stability (PAR T3), age at the start of treatment (T1), length of treatment (T2-T1), gender, and extraction. Orthodontic treatment produced a significant improvement of 94.2% in the PAR Index (T2-T1), but this change was not associated with the level of satisfaction when the patient was questioned at T3. No significant change was observed between T2 and T3. However, when the sample was divided according to the level of finalization (PAR T2), it was observed that well-finished patients experienced some deterioration (P<.001), whereas the less well-finished ones showed some improvement (P<.05). Even with the deterioration, the well-finished patients still had a better PAR Index at T3 compared to the less well-finished ones (PAR T2- T3). Regression analysis showed that PAR Index at T1 and T2, age at T1, and length of retainer wear had a slight association with occlusal stability (R2 = 0.27). Patient satisfaction was significantly associated only with PAR Index at T3 (r2=0.125, P<.0001). We can conclude that, even thought orthodontic treatment is quite stable, not so well-finished treatments tend to show some improvement and well-finished ones deteriorate some in the long-term. Despite of that, well-finished patients still have better occlusal characteristics. Patient satisfaction is not related to the result of orthodontic treatment; nevertheless, there is a slight association with dentition in the long-term / Este estudo objetivou avaliar os fatores relacionados ? estabilidade do tratamento ortod?ntico e o grau de satisfa??o dos pacientes em longo prazo. Foram selecionados 209 pacientes (88 classe I e 121 classe II), tratados com aparelhagem fixa straigth-wire com, pelo menos, 5 anos p?s-tratamento. Seiscentos e vinte e sete modelos foram examinados atrav?s do ?ndice PAR no pr?-tratamento (T1) no final do tratamento (T2) e em longo prazo (T3) m?dia de 8,5 anos. O question?rio do ?ndice Dental Impact Daily Living (DIDL) foi aplicado em T3 para avaliar a satisfa??o do paciente com sua oclus?o em longo prazo. Foram utilizados o teste de Friedman e a an?lise de regress?o linear m?ltipla para avaliar as mudan?as ocorridas nos per?odos de avalia??o e os fatores associados com a estabilidade e com o grau de satisfa??o, respectivamente. As vari?veis predictoras para o exame da oclus?o foram: ?ndice PAR em T1 e T2, idade em T1, tempo sem conten??o 3x3, tempo de uso da conten??o de Hawley, dura??o do tratamento, tempo de acompanhamento p?s-tratamento, g?nero, tratamento com e sem extra??o dent?ria e presen?a ou aus?ncia de terceiro molar. Para o grau de satisfa??o, as vari?veis foram: mudan?as produzidas pelo tratamento (PAR T2-T1), estabilidade p?stratamento (PAR T3), idade no in?cio do tratamento (T1), dura??o do tratamento (T2- T1), g?nero e extra??o dent?ria. O tratamento produziu uma melhora de 94,2% no ?ndice PAR (T2-T1), por?m isso n?o estava associado ao grau de satisfa??o quando o paciente foi questionado em (T3). Nenhuma mudan?a significativa foi observada entre T2 e T3, entretanto, quando a amostra foi dividida de acordo com o grau de finaliza??o (PAR T2), evidenciou-se que pacientes bem finalizados mostraram alguma altera??o no resultado do tratamento (P< 0,001), enquanto os casos n?o t?o bem finalizados apresentaram algum grau de melhora (P< 0,05). Entretanto, mesmo com alguma altera??o os casos bem finalizados ainda apresentaram um ?ndice PAR melhor em T3 quando comparado com os pacientes n?o t?o bem finalizados. A an?lise de regress?o mostrou que o ?ndice PAR em T1 e T2, a idade em T1 e a dura??o do uso da conten??o tiveram uma moderada associa??o com a estabilidade oclusal (R?= 0,27). Com rela??o ao grau de satisfa??o, apenas o ?ndice PAR em T3 apresentou uma rela??o significante (R? = 0.125, p < 0,0001). Pode-se concluir que, embora o tratamento ortod?ntico seja relativamente est?vel, em longo prazo, os casos mais bem finalizados tendem a uma pequena altera??o dos resultados, enquanto aqueles n?o t?o bem finalizados tendem a alguma melhora, por?m esses casos ainda s?o piores que os bem finalizados em longo prazo. O grau de satisfa??o do paciente n?o est? relacionado com o resultado do tratamento ortod?ntico, por?m h? uma suave associa??o com a oclus?o presente em longo prazo

Page generated in 0.0229 seconds