• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1590
  • 136
  • 93
  • 18
  • 11
  • 11
  • 11
  • 10
  • 9
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 1876
  • 443
  • 322
  • 289
  • 253
  • 242
  • 169
  • 165
  • 162
  • 153
  • 146
  • 142
  • 137
  • 124
  • 124
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Espalhamento acústico por superfícies ásperas

De La Cruz, John Raul Inga January 2009 (has links)
O espalhamento acústico por uma superfície continuamente diferenciável mas com tangente fractal, o chamado caso tipo III, primeiramente introduzido por Jakeman em [27] e [26], tem sido tratado computacionalmente para perturbações ásperas de superfícies planas e ilimitadas. O presente trabalho analisa teoricamente o espalhamento acústico de uma perturbação aleatória áspera de tipo III de um círculo, utilizando o método de campo nulo e aproximações assintóticas. Os resultados principais são: uma expressão assintótica de baixa ordem para a onda espalhada e o padrão de campo distante. Pela falta de artigos e livros tratando este tópico, o presente trabalho pretende servir como base para futuros trabalhos. / The acoustic scattering by continuously differentiable surface but with fractal tangent, the so-called type III case, first introduced by Jakeman in [27] and [26], has been treated computationally for rough perturbations of plane unbounded regions. The present work analises theorically the acoustic scattering of a random rough perturbation of type III of a circle, using the null field method and asymptotic techniques. The principal results are: an asymptotic expression of low order for the scattered wave and the far field pattern. Due to the lack of papers and books dealing with this topic the present work pretends to serve as a basis for future works.
182

Preenchimento de falhas de dados de ondas e cálculo da profundidade de fechamento para a região de Tramandaí, Rio Grande do Sul

Perotto, Heitor January 2010 (has links)
As ondas são uma das fontes energéticas mais importantes para a modelagem da geometria das costas em todo o mundo e constituem-se uma ameaça às obras costeiras e operações em mar aberto. O clima de ondas tem grande influência nos processos erosivos de uma praia com isso conhecer seu comportamento no tempo e no espaço é necessário para resolver as dinâmicas destes processos e também para a realização de obras costeiras, recuperação e reconstrução praial e operações em mar aberto. A profundidade de fechamento assim como o limite oceânico são parâmetros importantes para o estabelecimento dos limites de movimento dos sedimentos. Os objetivos deste trabalho são preencher as falhas de dados do ondógrafo, utilizando dois métodos estatísticos: regressão simples e regressão múltipla. E também calcular por meio de equações empíricas a profundidade de fechamento e o limite oceânico empregando-se os dados não preenchidos e os dados preenchidos. Este trabalho utilizou-se dados de um ondógrafo, coletados no ano de 2007 de Janeiro a Setembro na costa do litoral norte do Rio Grande do Sul. Para o preenchimento foi utilizado os métodos de regressão simples e múltipla utilizando dados do modelo WAVEWATCH III, procedentes do Centro de Previsão de Tempo e Estudos Climáticos e da estação meteorológica de Tramandaí. Com base nestes dados foram calculados diversos parâmetros estatísticos para verificar qual dos métodos alcançou a melhor resposta para o preenchimento das falhas. A profundidade de fechamento e o limite oceânico foram calculados utilizando fórmulas empíricas de Hallermeier (1981) e Birkemeier (1985) tanto para os dados não preenchidos como para os dados preenchidos. Os resultados obtidos mostraram que a regressão múltipla apresentou um melhor preenchimento segundo os parâmetros estatísticos e que os valores da profundidade de fechamento variaram entre 6,87 e 4,84 m, 6,62 e 4,74 m, 6,74 e 4,82 m para os dados não preenchidos, regressão simples e múltipla respectivamente e entre 30,20 e 24,80 m, 30,57 e 25,39 m, 30,77 e 25,51 m para o limite oceânico. / The waves are one of the most important energy sources for modeling the geometry of the coasts in the world and constitute a threat to coastal works and operations in open sea. The wave climate has a great influence on the erosion of a beach to know that their behavior in time and space is needed to resolve the dynamics of these processes and also to carry out coastal works, rehabilitation and reconstruction Beach Grass and open ocean operations. The closure depth and seaward limit are important parameters for establishing the limits of movement of sediments. The objectives are to conduct filling the gaps of data waverider, using two statistical methods: simple regression and multiple regression. And also calculate by empirical equations the closure depth and seaward limit using the data has not been completed and the data completed. This study used data from a waverider, collected in 2007 from January to September in the northern coast of Rio Grande do Sul to the filling has been used methods of simple and multiple regression model using data from WAVEWATCH III, coming Center for Weather Forecasting and Climate Studies and the meteorological station of Tramandaí. Based on these data were calculated several statistical parameters to determine which of the methods achieved the best answer to fill the gaps. The closure depth and seaward limit were calculated using empirical formulas of Hallermeier (1981) and Birkemeier (1985) data for both unfilled and filled to the data. The results showed that multiple regression analysis showed a better filling according to statistical parameters and the values of the closure depth varied between 6.87 and 4.84 m, 6.62 m and 4.74, 6.74 and 4, 82 m for the data is not filled, simple and multiple regression, respectively, and between 30.20 and 24.80 m, 30.57 m and 25.39, 30.77 and 25.51 m for the seaward limit.
183

Estudos experimentais de estrutura nuclear pelo método da correlação angular

Zawislak, Fernando Claudio January 1967 (has links)
Resumo não disponível
184

Estudo de cargas impulsivas com ênfase em explosões : estratégias de análises utilizando métodos numéricos

Casagrande, André Schaan January 2006 (has links)
A avaliação da solicitação produzida por explosões, assim como da resposta de estruturas, são temas de muito interesse na engenharia atualmente, tanto pela quantidade crescente de acidentes relacionados com explosões quanto pelas ações terroristas muitas vezes vinculadas a estes tipos de ações. Neste contexto, o presente trabalho tem por objetivo explorar técnicas de análise tanto na modelagem da excitação quanto na resposta de estruturas consideradas como alvos. Para isto, são utilizadas metodologias de diferentes tipos: implementações baseadas em sistema de elementos finitos comerciais como Ansys [2000] e LS-Dyna [2003] e técnicas simplificativas que permitem realizar uma avaliação preliminar. As aplicações consideradas são indicadas a seguir: • Análise da Resposta de Estruturas Laminares Submetidas à Ação de Cargas Explosivas: determina-se a pressão produzida por explosivos sólidos a certa distância do epicentro, através de métodos simplificados, determinando a resposta esperada em placas retangulares; • Efeito da Pressão Interna em Vasos de Pressão (Extintores de Incêndio): comparando resultados numéricos e experimentais verifica-se a influência da pressão interna nas propriedades dinâmicas do sistema; • Estudo de Um Vaso Esférico de GLP Sob Ação de Uma Carga Explosiva: aplica-se a ação de uma onda explosiva produzida por um gás inflamável pesado sobre uma estrutura de vaso de pressão esférico com fluido e gás em seu interior, determinando sua resposta, avaliando também a influência de diferentes quantidades de líquido e pressão interna na resposta da estrutura; • Modelamento de uma Camada de Solo / Propagação das Ondas: verifica-se o comportamento da propagação de ondas em um meio elástico, comparando valores encontrados em testes experimentais. Analisa-se numericamente o efeito da inserção de uma valeta na atenuação de tais ondas; • Simulação Numérica Completa de uma Explosão: modela-se um semi-espaço submetido à ação de um explosivo sólido sobre sua superfície, avaliando os campos de pressão gerados. Ao final de cada aplicação são apresentadas conclusões parciais obtidas e as possibilidades de trabalhos futuros vislumbrados. Finalmente, conclui-se que as técnicas empregadas para as simulações são extremamente eficientes, considerando conhecidos todos os parâmetros envolvidos em cada modelo. Neste ponto é fundamental o trabalho do engenheiro, utilizando-se de seus conhecimentos técnicos para transformação do evento real em um modelo numérico, considerando e selecionando as simplificações necessárias.
185

Estudo de propagação de onda eletromagnética em estrutura geológica estratificada

Vieira, Jairo Santos January 2003 (has links)
Resumo não disponível.
186

Efeito das ondas de choque extracorpóreas na desmite experimentalmente induzida em eqüinos

Caminoto, Elisa Holthausen [UNESP] January 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:44Z (GMT). No. of bitstreams: 0 Previous issue date: 2003Bitstream added on 2014-06-13T20:08:56Z : No. of bitstreams: 1 caminoto_eh_me_botfmvz.pdf: 3121128 bytes, checksum: f2d620bcb0d6defa02617e5d5dba563b (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este estudo teve por objetivo avaliar os efeitos da terapia por ondas de choque extracorpóreas na desmite induzida experimentalmente no ligamento suspensório do boleto do membro pélvico em eqüinos. Foram utilizados 10 eqüinos adultos submetidos à indução da lesão através de injeção de colagenase no ligamento suspensório do boleto de ambos os membros pélvicos. Após a indução da lesão, foram feitos o controle e a avaliação das lesões por ultra-sonografia e por parâmetros clínicos. Os animais foram submetidos ao tratamento por ondas de choque de um dos membros pélvicos, por três sessões, com intervalo de três semanas, e o membro contralateral foi deixado sem tratamento para servir como controle. A evolução da reparação foi avaliada por parâmetros clínicos, por ultra-sonografia e, ao final do experimento, através de biópsia para análise histopatológica, imunoistoquímica e ultra-estrutural. Na avaliação ultra-sonográfica, foi observado maior percentual de redução da área de lesão e melhora dos escores de paralelismo das fibras do membro tratado. Na avaliação histopatológica, os membros tratados apresentaram menor proliferação de vasos e fibroplasia. Na avaliação ultra-estrutural, os membros tratados apresentaram um aumento na quantidade de fibras colágenas de menor diâmetro nos membros tratados, refletindo a formação de novas fibrilas de colágeno, e na análise imunoistoquímica os membros tratados apresentaram maior expressão de TGFβ – 1. A terapia por ondas de choque extracorpóreas mostrou efeito positivo nas desmites experimentalmente induzidas nos eqüinos. / The aim of this study was to evaluate the effects of the extracorporeal shock wave therapy in experimentally induced suspensory desmitis on equine hind limb. Ten horses were submitted to collagenase injection in the suspensory ligament of both hind limbs. Ultrasound and clinical evaluation of the lesions was performed, and the horses were submitted to extracorporeal shock wave therapy in one of the hind limbs, three treatments, with interval of three weeks. The other hind limb was left untreated as control. The evolution of the healing process was monitored clinically and by ultrasound, and at the end of the study a biopsy was made to histopathology, immunocitochemistry and ultra structural evaluation. At the ultrasound evaluation, a greater proportion of reduction of the lesions and improvement of the parallelism scores were observed on treated limbs. At histopatological evaluation, treated limbs presented less fibroplasia and vascular proliferation. At ultra structural evaluation, treated limbs presented an increase in amount of small collagen fibrils, reflecting newly formed collagen fibrils. At immunocytochemistry, treated limbs presented greater expression of TGFβ – 1. The extracorporeal shock wave therapy had shown positive effects on experimentally induced desmitis in equine.
187

Efeitos da radiofrequência na cicatrização de feridas cutâneas em ratos : análise por planigrafia digital e avaliação histológica

Cepeda, Ana Maria Cardoso January 2015 (has links)
Orientador: Prof. Dr. Antônio Carlos Ligocki Campos / Co-orientador: Prof. Dr. Jorge Eduardo F.Matias / Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Ciências da Saúde, Programa de Pós-Graduação em Clínica Cirúrgica. Defesa: Curitiba, 13/07/2015 / Inclui referências f. 54-59 / Área de concentração : Clinica cirurgia / Resumo: Introdução: Tendo em vista o número de cirurgias plásticas no Brasil e a busca por melhores resultados estético-funcionais fazem-se necessárias pesquisas para encontrar meios para melhorar a cicatrização e as cicatrizes. Objetivo: Avaliar os efeitos de três sessões de radiofrequência na cicatrização da pele de ratos no 7º e 14º dia de cicatrização. Método: Quarenta e oito ratos machos foram divididos em 4 grupos (GC7, GR7, GC14 e GR14) conforme ao grupo que pertenciam (GC: grupo controle; GR: grupo radiofrequência) e o dia do sacrifício (7: 7º dia P.O; 14: 14º dia P.O). Sob anestesia com ketamina 80 mg/kg e xilazina 8 mg/kg foi realizado a tricotomia e antissepsia com PVPI. Logo em seguida, foi feita a marcação da ferida excisional com tamanho de 2cm x 2cm (4cm²) e utilizado a lâmina 20 nas bordas laterais do quadrado. Foi feita a dissecação do segmento da pele. Também utilizou-se um punch metálico de 6mm com lâmina cortante na sua borda inferior para a realização de duas feridas excisionais de 0,6cm de diâmetro. Após 24h, foi realizada a aplicação da radiofrequência com o equipamento Spectra® na região dorsal, diretamente sobre as feridas por 7 minutos com temperatura de 38ºC. Esse procedimento foi realizado por três vezes, em dias alternados. No grupo controle foi realizado o procedimento com o aparelho desligado. As feridas foram fotografadas em diferentes tempos pós-operatórios: dia da cirurgia, 1ºdia P.O, no 7º dia P.O e no 14º dia P.O. As áreas cruentas foram calculadas utilizando programa específico de computador. No sacrifício (7º P.O ou 14º P.O), as feridas foram ressecadas e fixadas, para posterior análise histológica com HE. Os resultados foram analisados estatisticamente. Resultados: Foi encontrada área maior na ferida quadrado, no 3º dia pós cirurgia do grupo radiofrequência (GR7 3,3cm² ± 0,7cm² X GC7 2,4cm² ± 0,4cm², p=0,009). A diferença no dia da cirurgia para o dia da eutanásia do GR14 e GC14 foi uma ferida maior no dia da eutanásia no GR14 quando comparado ao GC14 (GR14 1,9cm² ± 0,5cm² X GC14 1,0cm² ± 0,3cm², p=0,001). No 7º e 14º dia de pós-operatório as feridas dos grupos controle e experimento de todos os animais exibiram aspectos diferentes entre si. Houve fechamento de 90% das feridas no GC14. No GR14, 60% dos ratos com feridas de punch foram reepitelizadas, enquanto 40% permaneceram ulceradas. No GC7, 70% das feridas de punch permaneceram ulcerados e 30% foram reepitelizadas. Já no GR7, 8% dos ratos, com feridas de punch foram reepitelizadas e 92% dos ratos permaneceram ulcerados. Conclusão: Pode-se afirmar que a radiofrequência tem influência sobre o processo inflamatório mostrando que, nos ratos que foram aplicados a radiofrequência, o quadrado permaneceu ulcerado. A radiofrequência reduz a contração cicatricial em feridas excisionais. Palavras-chave: Ondas de Rádio. Cicatrização. Fibroblastos / Abstract: Introduction: Considering the number of plastic surgeries in Brazil and the search for better aesthetic-functional results, researches are necessary to find ways to improve the healing process and scars Objective: The objective of this study was to evaluate the effects of 3 sessions of the radiofrequency device in the cicatrization process of rat skins at 7 º and 14 º days of healing. Methods: Forty-eight male rats were divided into 4 groups (GC7, GR7, GR14 and GC14), according to the group (CG: control group; GR: RF group) and the day of sacrifice (7: 7th post-operative day; 14: 14th post-operative day). Under anesthesia with ketamine 80mg/kg and xylazine 8mg/kg, the trichotomy and antisepsis with PVP-I was done on each animal before marking the 2cm x 2cm (4cm²) excisional wound, to finally initiate surgery with No.20 blades on the sides of the marked square, dissecting the skin segment. A 6mm metal punch with a cutting blade at its lower edge was used as well. After 24h, the radio-frequency with Spectra® equipment was applied on the dorsal region for 7 minutes with a temperature of 38 °C. This procedure was performed three times on alternate days. The control group went through the process with Spectra® turned off. The wounds were photographed at different post-operative stages: Surgery day, 1º day PO, 7º day PO and 14º day PO the raw areas were calculated using specific computer program. We reevaluated histologically with HE. Results were statistically analyzed by non-parametric Mann-Whitney test, p<0, 05. Results: Larger area in the wound square was found, on the 3rd day after surgery in radiofrequency group (GR7 3,3cm² ± 0,7cm² x GC7 2,4cm² ± 0,4cm², p=0,009).The difference between surgery day to euthanasia of the GC14 and GR14 is a smaller wound on euthanasia day in C14 compared to R14, (GR14 1,9cm² ± 0,5cm² x GC14 1,0cm² ± 0,3cm², p=0,001).On 7th and 14th postoperative days, wounds of control and experimental groups of all animals exhibit different aspects. There was 90% closure of wounds in the GC14. 60% of the rats in the GR14 had epidermal regeneration while 40% remaining ulcerated. In GC7, 70% of punch wounds remained ulcerated and 30% was healed. The GR7 had 8% rats with punch wounds healed and 92% remained ulcerated. Conclusion: It can be said that the radio has influence on the inflammatory process, showing negative effects applying RF; the Q-square remained ulcerated. This, study have found harmful results about the application of radiofrequency in the initial PO. However, it is necessary to conduct more studies to elucidate the action mechanism of RF in skin wounds healing. Keywords: Radio Waves. Cicatrization. Fibroblasts
188

Estudo comparativo de potenciais evocados visuais entre diferentes equipamentos Nihon Kohden / Comparative study of visual evoked potentials between diferent Nihon Kohden equipments

Pereira, Vanessa Caldeira [UNESP] 03 May 2017 (has links)
Submitted by VANESSA CALDEIRA PEREIRA null (van_caldeira@hotmail.com) on 2017-06-13T15:16:21Z No. of bitstreams: 1 V-TESE-FINAL-06-04-2017.doc: 2223616 bytes, checksum: a35d07356012535ce841f6cc9d384e4c (MD5) / Rejected by Luiz Galeffi (luizgaleffi@gmail.com), reason: Solicitamos que realize uma nova submissão seguindo as orientações abaixo: A versão final da dissertação/tese deve ser submetida no formato PDF (Portable Document Format). O arquivo PDF não deve estar protegido e a dissertação/tese deve estar em um único arquivo, inclusive os apêndices e anexos, se houver. Sua tese/dissertação deve estar de acordo com as normas de sua unidade/programa de pós-graduação, encontradas no link abaixo: http://www.fmb.unesp.br/Home/Pos-Graduacao/mestradoacademicoedoutorado/pgbasesgeraisdacirurgia/bases-gerais-da-cirurgia-01-07-2015-pg-pdf.pdf Por favor, corrija o formato do arquivo e realize uma nova submissão. Agradecemos a compreensão. on 2017-06-13T17:40:33Z (GMT) / Submitted by VANESSA CALDEIRA PEREIRA null (van_caldeira@hotmail.com) on 2017-06-15T20:49:33Z No. of bitstreams: 1 V-TESE-FINAL-06-04-2017.pdf: 1457681 bytes, checksum: fe7cccf59a202c11ede49f405cf80220 (MD5) / Rejected by Luiz Galeffi (luizgaleffi@gmail.com), reason: Solicitamos que realize uma nova submissão seguindo as orientações abaixo: Seu arquivo deve estar de acordo com a Instrução Normativa nº 001/2015, de 29 de abril de 2015, do Conselho do Programa de Pós-graduação em Bases Gerais da Cirurgia, encontrada na página 12 do documento no link abaixo: http://www.fmb.unesp.br/Home/Pos-Graduacao/mestradoacademicoedoutorado/pgbasesgeraisdacirurgia/bases-gerais-da-cirurgia-01-07-2015-pg-pdf.pdf Para maiores dúvida sobre as normas de sua unidade, entre em contato com seu programa de pós-graduação. Atenciosamente. on 2017-06-19T13:15:06Z (GMT) / Submitted by VANESSA CALDEIRA PEREIRA null (van_caldeira@hotmail.com) on 2017-06-30T13:35:21Z No. of bitstreams: 1 Dissertação para arquivamento.pdf: 1265018 bytes, checksum: 1364017705c245744d580c2a1f304d28 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-06-30T14:32:35Z (GMT) No. of bitstreams: 1 pereira_vc_me_bot.pdf: 1265018 bytes, checksum: 1364017705c245744d580c2a1f304d28 (MD5) / Made available in DSpace on 2017-06-30T14:32:35Z (GMT). No. of bitstreams: 1 pereira_vc_me_bot.pdf: 1265018 bytes, checksum: 1364017705c245744d580c2a1f304d28 (MD5) Previous issue date: 2017-05-03 / Potenciais evocados visuais (PEV) avaliam vias visuais para fins clínicos. Os objetivos deste estudo foram comparar morfologias e latências de ondas P100, obtidas com diferentes bandas passantes de filtros, em 2 equipamentos distintos de um mesmo fabricante (5 – 20 Hz, e 5 – 100 Hz, Grupo I) e, após escolha da melhor banda passante de filtros, comparar valores de latências de ondas P100 obtidas em 2 equipamentos distintos de um mesmo fabricante, em voluntários normais (Grupo II) e em pacientes com queixas de alterações visuais (Grupo III). Todos os procedimentos foram realizados em equipamentos Nihon-Kohden, modelos Neuropack 2 e MEB 9400. No Grupo I, nos 2 equipamentos, filtros de 5 – 20 Hz proporcionaram registros gráficos melhores e mais nítidos, porém com latências mais prolongadas, em relação aos filtros de 5 a 100 Hz (média de 8 milissegundos, p < 0,0001). Em 20 voluntários do Grupo II e 30 pacientes do grupo III, todos avaliados com filtros de 5 a 20 Hz, observaram-se latências mais prolongadas, em média 6 a 8 milisegundos, utilizando-se equipamento MEB 9400 (p < 0,0001). Em conclusão, filtros de 5 a 20 Hz possibilitaram registros de melhor qualidade das ondas P100, com latências mais prolongadas, se comparados aos filtros de 5-100 Hz. Além disso, utilizando-se a mesma banda passante de filtros, e todas as outras condições técnicas idênticas, diferentes equipamentos, de um mesmo fabricante, fornecem valores distintos de latências das ondas P100, para voluntários normais ou pacientes (p < 0,0001). / Visual evoked potentials (VEP) evaluate visual pathways for clinical purposes. The objective of this study were to compare P100 wave latencies and morphologies obtained with different band-pass filter in 2 different equipments from the same manufacturer (5 - 20 Hz, and 5 - 100 Hz, Group I). After choosing the best band-pass filter for the record of the P100 waves, latencies were compaired between 2 equipments of the same manufacture. All procedures were obtained from Nihon-Kohden equipments, Neuropack 2 and MEB 9400 models. For the Group I, in the 2 equipments, 5 - 20 Hz band-pass filter furnished better and clearer graphic records, but with longer latencies, in relation to the 5 - 100 Hz band-pass filter (mean of 8 milliseconds, p <0.0001). For the 20 volunteers (Group II) and 30 patients (Group III), all evaluated with 5 – 20 Hz band-pass filter, longer latencies were observed, on average 6 to 8 milliseconds, using MEB 9400 equipment (p <0, 0001). In conclusion, 5 to 20 Hz band-pass filter allowed better quality records of the P100 waves, with longer latencies, if compared to the 5-100 Hz band-pass filter. In addition, using the same filter band-pass, and all of the other technical parameters identical, different equipments from the same manufacturer provide different P100 latency values for normal volunteers or patients (p <0.0001).
189

Otimização da síntese das zeólitas NaA e NaX utilizando radiação de micro-ondas para aplicação como agentes hemostáticos coagulantes / NaA and NaX zeolites synthesis optimization employing microwave radiation and their application as coagulation agents

Povinelli, Ana Paula Ribeiro [UNESP] 18 July 2017 (has links)
Submitted by Ana Paula Ribeiro Povinelli (paulinha-pol@hotmail.com) on 2017-07-26T19:45:49Z No. of bitstreams: 1 Dissertacao_Ana_FINAL.pdf: 3540005 bytes, checksum: d82bc4d015af48c2fda01a4eff17975f (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-07-26T20:13:00Z (GMT) No. of bitstreams: 1 povinelli_apr_me_sjrp.pdf: 3540005 bytes, checksum: d82bc4d015af48c2fda01a4eff17975f (MD5) / Made available in DSpace on 2017-07-26T20:13:00Z (GMT). No. of bitstreams: 1 povinelli_apr_me_sjrp.pdf: 3540005 bytes, checksum: d82bc4d015af48c2fda01a4eff17975f (MD5) Previous issue date: 2017-07-18 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / A substituição da fonte de calor convencional por fontes de radiação de micro-ondas vem sendo bastante explorada na área de síntese de sólidos inorgânicos devido ao seu eficaz mecanismo de entrega de energia que proporciona rapidez no processo de síntese além de gerar materiais com maior pureza de fase. Neste contexto, o presente trabalho visou a otimização das sínteses das zeólitas NaA e NaX utilizando radiação de micro-ondas e a caracterização utilizando as técnicas de DRX (Difração de Raios-X), MEV (Microscopia eletrônica de varredura) e EDS (Energy-dispersive X-Ray Spectrocopy). As zeólitas foram sintetizadas e caracterizadas visando a posterior aplicação como agentes hemostáticos coagulantes. Os experimentos mostraram que a zeólita NaA obtida utilizando radiação de micro-ondas durante 30 minutos possui as mesmas características da zeólita NaA sintetizada utilizando aquecimento convencional por 48 horas, indicando que com a utilização da radiação foi possível alcançar uma redução de 98,96% no tempo de síntese. A aplicação de aquecimento de micro-ondas na síntese da zeólita NaX também provou decréscimo no tempo de síntese quando comparado ao aquecimento convencional, entretanto os dados de microscopia eletrônica revelaram que a zeólita sintetizada pelo aquecimento de micro-ondas estavam aglomeradas. A fim de tornar o coloide mais estável, foi feita a estabilização estérica dessas zeólitas através da esterificação dos grupos silanóis presentes na superfície das mesmas utilizando 1-propanol e 1-butanol. Os dados MEV mostraram que a modificação foi eficiente e que a dispersão foi estabilizada após o tratamento. Em relação ao potencial das zeólitas como agentes hemostáticos coagulantes, os dados de tromboelastografia mostraram que as zeólitas NaA e NaX provocaram diminuição no tempo necessário para a formação e crescimento do coágulo porém, dentre todas as zeólitas avaliadas, a zeólita NaX sintetizada por aquecimento convencional se destacou como agente hemostático apresentando uma redução de 6 minutos no tempo de formação do coágulo. / Conventional heat source has been substituted by microwave heat source in many chemical reactions including inorganic solids syntheses, since the microwave heat source can accelerate the energy delivery. Because of that, it is possible to obtain syntheses in a shorter time and materials obtained have a higher purity phases. Zeolites were synthesized and characterized aiming to zeolites hemostatic agents application. In this context, this work aimed to synthesize NaA and NaX zeolites employing microwave radiation and to characterize materials obtained using XRD (X-Ray Diffraction), SEM(Scanning Electron Microscopy) and EDS (Energy-dispersive X-Ray Spectrocopy) techniques. NaA zeolite obtained by microwave radiation after 30 minutes showed the same characteristics of NaA zeolite obtained by conventional heat after 48 hours. In other words, the substitution of the heat source reduced 98,96% the synthesis time. Related to NaX zeolite, microwave radiation also reduced the synthesis time, however SEM and EDS data showed some differences between NaX obtained by conventional and NaX obtained by microwave heating. It was also observed by SEM that the colloidal system of NaX obtained by microwave radiation has agglomerated. In order to stabilize sterically the colloid, NaX surface was functionalized by silanols groups esterification using 1-propanol and 1-butanol alcohols. SEM data showed that steric stabilization was successful. Regarding the potential of the zeolites as hemostatic coagulating agents, thromboelastography data showed that NaA and NaX zeolites caused decrease in time required for clot formation and growth. However, among all the zeolites evaluated, NaX zeolite synthesized by conventional heating had better results as a hemostatic agent showing a reduction of 6 minutes in clot formation time. / CNPq: 135582/2015-6
190

Efeito das ondas de choque extracorpóreas na desmite experimentalmente induzida em eqüinos /

Caminoto, Elisa Holthausen. January 2003 (has links)
Orientador: Ana Liz Garcia Alves / Resumo: Este estudo teve por objetivo avaliar os efeitos da terapia por ondas de choque extracorpóreas na desmite induzida experimentalmente no ligamento suspensório do boleto do membro pélvico em eqüinos. Foram utilizados 10 eqüinos adultos submetidos à indução da lesão através de injeção de colagenase no ligamento suspensório do boleto de ambos os membros pélvicos. Após a indução da lesão, foram feitos o controle e a avaliação das lesões por ultra-sonografia e por parâmetros clínicos. Os animais foram submetidos ao tratamento por ondas de choque de um dos membros pélvicos, por três sessões, com intervalo de três semanas, e o membro contralateral foi deixado sem tratamento para servir como controle. A evolução da reparação foi avaliada por parâmetros clínicos, por ultra-sonografia e, ao final do experimento, através de biópsia para análise histopatológica, imunoistoquímica e ultra-estrutural. Na avaliação ultra-sonográfica, foi observado maior percentual de redução da área de lesão e melhora dos escores de paralelismo das fibras do membro tratado. Na avaliação histopatológica, os membros tratados apresentaram menor proliferação de vasos e fibroplasia. Na avaliação ultra-estrutural, os membros tratados apresentaram um aumento na quantidade de fibras colágenas de menor diâmetro nos membros tratados, refletindo a formação de novas fibrilas de colágeno, e na análise imunoistoquímica os membros tratados apresentaram maior expressão de TGFβ - 1. A terapia por ondas de choque extracorpóreas mostrou efeito positivo nas desmites experimentalmente induzidas nos eqüinos. / Abstract: The aim of this study was to evaluate the effects of the extracorporeal shock wave therapy in experimentally induced suspensory desmitis on equine hind limb. Ten horses were submitted to collagenase injection in the suspensory ligament of both hind limbs. Ultrasound and clinical evaluation of the lesions was performed, and the horses were submitted to extracorporeal shock wave therapy in one of the hind limbs, three treatments, with interval of three weeks. The other hind limb was left untreated as control. The evolution of the healing process was monitored clinically and by ultrasound, and at the end of the study a biopsy was made to histopathology, immunocitochemistry and ultra structural evaluation. At the ultrasound evaluation, a greater proportion of reduction of the lesions and improvement of the parallelism scores were observed on treated limbs. At histopatological evaluation, treated limbs presented less fibroplasia and vascular proliferation. At ultra structural evaluation, treated limbs presented an increase in amount of small collagen fibrils, reflecting newly formed collagen fibrils. At immunocytochemistry, treated limbs presented greater expression of TGFβ - 1. The extracorporeal shock wave therapy had shown positive effects on experimentally induced desmitis in equine. / Mestre

Page generated in 0.0602 seconds