• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 99
  • 14
  • 1
  • Tagged with
  • 116
  • 30
  • 30
  • 28
  • 24
  • 21
  • 20
  • 16
  • 15
  • 13
  • 13
  • 12
  • 12
  • 12
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efeitos do maleato de timolol, do levobunolol e da apraclonidina sobre a pressão intra-ocular, o diâmetro pupilar, a frequência cardíaca e a pressão sanguínea em cães da raça Beagle

Martinez Padua, Ivan Ricardo [UNESP] 14 December 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:42Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-12-14Bitstream added on 2014-06-13T19:50:45Z : No. of bitstreams: 1 martinezpadua_ir_me_jabo.pdf: 470356 bytes, checksum: ed3ca885b2025dab8eda4d07f31ede86 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Considerando-se que o glaucoma é a principal causa de perda da visão no homem e nos animais, e que o seu manejo clínico é a forma mais empregada para se controlar a síndrome, estudos comparativos que avaliem a eficácia de agentes hipotensores oculares constituem tema atual. Assim, foram avaliados os efeitos do timolol 0,5%, do levobunolol 0,5% e da apraclonidina 0,5% sobre a pressão intraocular (PIO), o diâmetro pupilar (DP), a frequência cardíaca (FC) e a pressão arterial sanguínea sistólica (PS) em cães clinicamente normais. Para tanto, 10 cães machos foram previamente condicionados aos procedimentos a que seriam submetidos, durante três dias. No dia zero, a PIO, o DP, a FC e a PS foram avaliados em três momentos (manhã, tarde e noite), para a avaliação dos valores basais. Os fármacos foram testados separadamente, a intervalos de sete dias, para que os efeitos de um não interferissem com os dos demais. Durante 15 dias consecutivos, um olho de cada animal recebia uma gota de timolol 0,5% ou de levobunolol 0,5% ou de apraclonidina 0,5% a intervalos de 12 horas (7 e 19 horas). Os parâmetros foram mensurados às 8, 13 e às 20 horas, ao 3º, 6º, 9º, 12º viii e 15º dias. Os dados foram comparados estatiscamente, empregando-se o Teste de Bonferroni, após Análise de Variância para Medidas Repetidas (p<0,05). Alterações da PIO não foram observadas após o uso dos fármacos testados. Por sua vez, com o uso do timolol, não foram observadas alterações significativas no DP nos momentos avaliados. Entretanto, foi observada redução significativa do DP na quase totalidade dos animais que receberam levobunol. Em relação ao período basal, observou-se elevação do DP apenas ao 3º dia de avaliação, após o uso de apraclonidina. Quanto à PS, apenas a apraclonidina interferiu com o parâmetro, reduzido-o de maneira significativa em todos os períodos avaliados em cães... / Not available
2

Comparação da eficácia das lentes intraoculares restor esférica - SN60D3 - e restor asférica - SN6AD3

Porfírio Neto Junior, Francisco January 2009 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, 2009. / Submitted by Allan Wanick Motta (allan_wanick@hotmail.com) on 2010-04-01T12:24:19Z No. of bitstreams: 1 2009_FranciscoPNJunior.pdf: 873921 bytes, checksum: b8c21f11bac2583450a9d6fe651959a3 (MD5) / Approved for entry into archive by Lucila Saraiva(lucilasaraiva1@gmail.com) on 2010-05-21T16:26:57Z (GMT) No. of bitstreams: 1 2009_FranciscoPNJunior.pdf: 873921 bytes, checksum: b8c21f11bac2583450a9d6fe651959a3 (MD5) / Made available in DSpace on 2010-05-21T16:26:57Z (GMT). No. of bitstreams: 1 2009_FranciscoPNJunior.pdf: 873921 bytes, checksum: b8c21f11bac2583450a9d6fe651959a3 (MD5) Previous issue date: 2009 / Objetivos: comparar a eficácia visual para longe, perto e intermediário com e sem correção das lentes intraoculares multifocais difrativas apodizadas Restor Asférica - SN6AD3 - e Restor Esférica - SN60D3 -, além de avaliar a performance visual destas lentes por meio do exame de aberrometria. Metodologia Científica: 68 olhos foram submetidos à facoemulsificação com implante de lente intraocular multifocal Restor Asférica e Restor Esférica. No 3 mês de pós-operatório, foram avaliadas, em condições fotópicas (85 cd/m2), as acuidades visuais, com e sem correção, para longe (6 metros), perto (33 cm) e intermediário (60 cm). Todos os pacientes foram submetidos ao exame de aberrometria e comparados os resultados por meio de testes estatísticos paramétricos e não-paramétricos (teste de Kruskal-Wallis e teste t-Student). Resultados: Os pacientes analisados (72,23% femininos) tinham idade média de 70 anos, variando de 58 a 79 anos. A dioptria das lentes intraoculares multifocais implantadas nos pacientes deste estudo apresentouse dentro dos valores mais comuns, onde 83,8% dos pacientes usaram lentes intraoculares com medidas entre 20 e 24 dioptrias, com uma média de 21,4 e com desvio padrão de 2,1. A medida da acuidade visual média dos pacientes com lente Restor Asférica foi pior na distância intermediária, onde a Acuidade Visual foi, aproximadamente, de 20/32 (J4) com e sem correção. Para perto e longe, a AV das lentes asféricas ficou em torno de 20/20 com correção. Os pacientes com lente Restor Esférica também apresentaram acuidade visual, em média, de 20/20, para perto e para longe, com correção. Na distância intermediária a AV foi, em média, de 20/30 (J3) sem correção e 20/32 com correção. Nessas lentes, a acuidade visual para longe, sem correção, alcançou a média de 20/25. Não houve diferenças estatisticamente significativas entre as lentes esféricas e asféricas nas acuidades visuais para perto sem correção (p=0,345), para perto com correção (p=0,903), para intermediário sem correção (p=0,798), para intermediário com correção (p=0,743) e para longe com correção (p=0,133). A lente Restor Asférica apresentou melhor acuidade visual para longe sem correção (p=0,000). Não existiu diferença estatística entre as medidas do equivalente esférico (p=0,965) e das aberrações do olho (aberração total 5mm - p=0,273) (aberração total 6mm p=0,742) (HOA 5mm p=0,556) (HOA 6mm p=0,339) (aberração esférica 6mm p=0,360) entre a lente asférica e esférica. Conclusões: Não foram observadas diferenças estatisticamente significativas entre as lentes multifocais Restor Asférica e Restor Esférica nas visões de perto e intermediário com e sem correção. A Restor Asférica alcançou melhor acuidade visual para longe, sem correção, do que a Restor Esférica. Quando o erro refracional foi corrigido, a acuidade visual para longe das lentes se aproximou e deixou de ter significância estatística, além da inexistência de diferença entre as medidas do equivalente esférico e das aberrações do olho entre a lente asférica e esférica. _______________________________________________________________________________________ ABSTRACT / PURPOSE: To compare distance, intermediate and near visual acuity (VA) ,uncorrected and best corrected, and ocular aberrations in patients who had multifocal aspherical and spherical apodized diffractive intraocular lens (IOL) implantation (Restor, Alcon). METHODS: The best corrected visual acuity (BCVA), uncorrected visual acuity (UCVA), distance corrected near visual acuity (DCNVA), uncorrected near visual acuity (UCNVA), uncorrected intermediate visual acuity (UCIVA), distance corrected intermediate visual acuity (DCIVA) and ocular aberrations were measured in 68 eyes who had multifocal aspherical and spherical apodized diffractive intraocular lens (IOL) implantation (Restor, Alcon). Ocular aberrations with a 5.0 mm and 6.0 mm pupil were measured with a Hartmann-Shack aberrometer. All patients were followed for 3 months. RESULTS: The mean age of the 25 women and 9 men was 70 years ( range of 58 the 79 years). There were no statistically significant differences between eyes in postoperative uncorrected and best corrected near and intermediate visual acuities after a follow-up of 3 months. The dioptry of the implanted multifocal intraocular lenses was presented between the most common values. 83.8% of the patients had implanted intraocular lens between 20 and 24 dioptries (mean 21,5 D 2,0 D). The mean best corrected visual acuity (BCVA), distance corrected near visual acuity (DCNVA), uncorrected near visual acuity (UCNVA) were 20/20 in aspherical group. In this group, uncorrected and best corrected intermediate visual acuity (UCIVA) were worst (mean 20/32- J4 ). In the spherical group, the mean best corrected visual acuity (BCVA) and distance corrected near visual acuity (DCNVA) were 20/20. The mean uncorrected intermediate visual acuity (UCIVA) was 20/30 and the mean best distance corrected intermediate visual acuity (DCIVA) was 20/32. In spherical group, the mean uncorrected visual acuity (UCVA) was 20/25. There were no statistically significant differences between the groups in best corrected visual acuity (BCVA) (p=0,133), distance corrected near visual acuity (DCNVA) (p=0,903), uncorrected near visual acuity (UCNVA) (p=0,345), uncorrected intermediate visual acuity (UCIVA) (p=0,798), distance corrected intermediate visual acuity (DCIVA) (p=0,743) . The uncorrected visual acuity (UCVA) was better in patients with an AcrySof ReSTOR Aspherical SN6AD3 (p=0,000).There were no statistically significant differences in spherical equivalent (p=0,965), total aberration with 5 mm pupil diameter (p=0,273), total aberration with 6 mm pupil diameter (p=0,742), high-order aberration(HOA) with 5 mm pupil diameter (p=0,556), high-order aberration(HOA) with 6 mm pupil diameter (p=0,339) and spherical aberration (p=0,360) between the groups. CONCLUSIONS: There were no statistically significant differences between eyes in postoperative best corrected visual acuity (BCVA), distance corrected near visual acuity (DCNVA), uncorrected near visual acuity (UCNVA), uncorrected intermediate visual acuity (UCIVA), distance corrected intermediate visual acuity (DCIVA) and ocular aberrations. The uncorrected visual acuity (UCVA) was better in patients with an AcrySof ReSTOR Aspherical SN6AD3.
3

Red blood cell (RBC) - Teste de hemólise: uma alternativa ao teste de Draize-irritação ocular na avaliação do poder tóxico de produtos cosméticos no controle de qualidade / Red blood cell (RBC) - Hemolysis test: an alternative to the test of ocular Draize-irritation in the evaluation of the toxicant power of cosmetic products in the quality control

Alves, Eloisa Nunes January 2003 (has links)
Made available in DSpace on 2014-09-24T12:58:32Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 170.pdf: 2427185 bytes, checksum: 0bf00a5fbc2821c8dcd7fdd3a2524593 (MD5) Previous issue date: 2003 / O objetivo do presente trabalho, foi o de correlacionar os resultados obtidos em Teste convencional in vivo, de Draize de Irritação ocular, em coelhos, que preconiza o estudo quantitativo das lesões induzidas por produtos cosmétidos na conjuntiva, córnea e íris, com os resultados do Teste RBC, in vitro, que preconiza a análise quantitativa da hemólise e desnaturação protéica induzidas pelos mesmos produtos, em eritrócitos de mamíferos, com a finalidade não só de validar este último como um Teste preliminar capaz de selecionar produtos altamente irritantes, excluindo-os do Teste de Draize, bem como avaliar o Teste in vitro, como uma alternativa válida para uma eventual substituição do Teste in vivo. Para isto, realizamos estudo paralelo in vivo/in vitro de 23 substâncias-teste (19 podutos cosméticos e 4 tensoativos) procurando relacionar as lesões das 3 estruturas oculares, quantificadas por escores, com os 3 parâmetros in vitro, referentes à indução, em eritrócitos de carneiro, (i) de hemólise (H50) e (ii) de desnaturação protéica (ID), cuja razão H 50/ID, reflete o Potencial de Irritação(PI) das substâncias-teste. Em termos de tensoativos, obtivemos expressivas correlações entre as médias dos escores máximos (MEM) das lesões das três estruturas oculares, com os efeitos induzidos nos 3 parâmetros in vitro, com Coefs. Correlação de Pearson (CCP) de 0,900 a 0,988. Resultados análogos ocorreram com os produtos cosméticos em relação à conjuntiva e córnea (CCP: 0,682 a 0,788) porém, em menor escala, em relação à íris. (CCP: 0,513 a 0,519), Portanto, o Ensaio RBC pode ser usado como screening para avaliar o PI de produtos cosméticos que contenham tensioativos pois revelou-se capaz de predizer, com um elevado nível de precisão (96 por cento) o valor desse PI. Além disso mostrou elevados graus de sensibilidade e especificidade, com índices da ordem de 94 e 100 por cento respectivamente. / The objective of the present study was to correlate the results obtained in vivo with the standard Draize test of ocular irritation, which permits a quantitative study of the lesions induced by cosmetic products in the conjunctiva, cornea and iris, with the in vitro results of the sheep red blood cell (RBC) test, which permits a quantitative analysis of the hemolysis and protein denaturation induced by the same products in mammalian erythrocytes, in order not only to validate the latter as a preliminary test capable of selecting highly irritating products, excluding them from the Draize test, but also to evaluate the in vitro test as a valid alternative for an eventual replacement of the in vivo test. To this end, we performed a parallel in vivo/in vitro study of 23 test substances (19 cosmetic products and 4 tensoactive agents) in order to relate the lesions of the 3 ocular structures, quantified by scores, to the 3 in vitro parameters concerning the induction of (i) hemolysis (H50) and (ii) protein denaturation (ID) in sheep RBC whose H 50/ID ratio reflects the irritation potential (IP) of the test substances. With respect to the tensoactive agents, we obtained significant correlations between mean maximum scores for the lesions of the three ocular structures and the effects induced on the 3 in vitro parameters, with Pearson correlation coefficients (PCC) of 0.900 to 0.988. Similar results were obtained for the cosmetic products with respect to the conjunctiva and the cornea (PCC: 0.682 to 0.788) although to a lesser extent compared to the iris (PCC: 0.513 to 0.519), Thus, the RBC assay can be used as a screening method to assess the IP of cosmetic products containing tensoactive agents since it proved to be able to predict the IP value with a high level of accuracy (96%). In addition, the assay showed high sensitivity and specificity rates of 94 and 100%, respectively.
4

Avaliação da eficácia das lentes intra-oculares hidrofílicas expansíveis: ensaio clínico randomisado

Medeiros, Hilton Arcoverde Gonçalves de 09 September 2006 (has links)
Tese (doutorado)-Universidade Federal de Goiás, Faculdade de Medicina, 2006. / Submitted by samara castro (sammy_roberta7@hotmail.com) on 2010-10-27T18:18:46Z No. of bitstreams: 1 2006-Hilton Arcoverde Gonçalves de Medeiros.pdf: 715691 bytes, checksum: 6f4a068da4007978fdb6d8f06bf6d3cc (MD5) / Approved for entry into archive by Daniel Ribeiro(daniel@bce.unb.br) on 2010-10-28T00:13:54Z (GMT) No. of bitstreams: 1 2006-Hilton Arcoverde Gonçalves de Medeiros.pdf: 715691 bytes, checksum: 6f4a068da4007978fdb6d8f06bf6d3cc (MD5) / Made available in DSpace on 2010-10-28T00:13:54Z (GMT). No. of bitstreams: 1 2006-Hilton Arcoverde Gonçalves de Medeiros.pdf: 715691 bytes, checksum: 6f4a068da4007978fdb6d8f06bf6d3cc (MD5) / Objetivo: Comparar o comportamento das lentes intra-oculares (LIO) acrílicas hidrofílicas expansíveis com o das LIO acrílicas hidrofóbicas. Metodologia: Sessenta e seis pacientes foram submetidos à cirurgia da catarata. Para um olho foi randomizado o implante de LIO acrílica hidrofílica expansível, enquanto o olho contra-lateral recebeu a LIO acrílica hidrofóbica. Os pacientes foram acompanhados por 12 meses, registrando-se informações sobre a incidência de opacificação de cápsula posterior, de descentralização da zona óptica da LIO, grau esférico (equivalência esférica) residual de cada olho, perda de células endoteliais e a melhor acuidade visual corrigida. Resultados: Quatro olhos (6,1%) com LIO hidrofílicas e dois olhos (3,0%) com LIO hidrofóbicas apresentaram opacificação de cápsula posterior (diferença não significativa, onde p>0,05). Cinco olhos (7,6%) com LIO hidrofílica expansível e três olhos (4,5%) com LIO hidrofóbica apresentaram descentralizações inferiores a 1 mm (diferença não significativa). Registraram-se 12,06% de perda de células endoteliais nos olhos com LIO hidrofílica e 12,43% nos olhos com LIO hidrofóbica (diferença não significante). Não se observou diferença significativa quanto à melhor acuidade visual corrigida entre os dois tipos de lentes. Conclusões: Os achados sugerem que a LIO acrílica hidrofílica expansível apresenta segurança e eficácia semelhantes em relação à LIO acrílica hidrofóbica. _________________________________________________________________________________ ABSTRACT / Object: To evaluate the efficacy of the use of hydrophilic acrylic expandable intra ocular lenses (IOL) compared with the hydrophobic acrylic IOL. Methodology: Sixty-six patients with cataract were submitted to cataract surgery. For one eye there was randomized the implant of the acrylic hydrophilic expandable IOL, while the other eye received the hydrophobic acrylic IOL. The follow-up was 12 months and was observed the incidence of posterior capsule opacification (PCO), decentralization of the optic zone of the IOL, the espheric diopter (espheric equivalence) after the surgery, lost of endothelial cells, and the best-corrected visual acuity (BCVA). Results: From the total of 66 eyes with each IOL, 4 eyes (6,1) with hydrophilic IOL and 2 eyes (3,0%) with hydrophobic IOL showed PCO, but it was not statistically significant (p>0,05). 5 eyes (7,6%) with hydrophilic IOL and 3 eyes (4,5%) with hydrophobic IOL showed decentralization inferior to 1 mm, but that value also was not statistically significant (p>0,05). It was observed an endothelial cell lost of 12,06% in eyes with hydrophilic IOL while in eyes with hydrophobic IOL the mean lost was 12,43%, also not statistically significant. In relation to espheric equivalence after surgery, we observed a slight tendency to more homogeneous optical results in eyes with hydrophobic IOL, and very close BCVA. No statistically significant difference has been shown. Conclusions: The present study suggests that the hydrophilic acrylic expandable IOL has a similar efficacy and safety. Key-words: Cataract, phacoemulsification, intraocular lens, posterior capsule opacification, decentralization, spherical equivalence, endothelial cell loss.
5

Movimientos oculares como marcadores de la percepción de objetos visuales

Plaza Rosales, Ivan Antonio January 2016 (has links)
Grado de magíster en neurociencias / Nuestra percepción visual típicamente incluye la segmentación de objetos en una escena visual. Sin embargo, los mecanismos que determinan la construcción de estos objetos visuales son desconocidos. La exploración visual implica varios movimientos oculares tales como fijaciones, sacadas y microsacadas. Proponemos que la percepción visual de un objeto se constituye a través de la agrupación espacial de microsacadas y estas se correlacionan con el informe de los objetos percibidos, independientemente del tamaño y dependiente de la forma de estos objetos. Aquí, se muestra que usando una tarea de exploración libre, la agrupación de patrones de microsacadas se correlaciona de manera efectiva con los objetos percibidos. Contrastado con mapas de saliencia indican que las regiones con una mayor presencia de microsacadas representan la percepción de un objeto y no sólo son zonas que se destacan de la imagen por sus características físicas. La agrupación de microsacadas fue independiente del tamaño de los objetos percibidos, manteniendo el tamaño absoluto de la agrupación al escalar las imágenes de estímulo. Finalmente, encontramos que la disposición espacial de microsacádicos es dependiente de la forma de los objetos reportados, adoptando una forma parcial de acuerdo a la naturaleza de los objetos. Estos resultados pueden contribuir a la caracterización de la percepción de los objetos en una escena y arrojar luz sobre los mecanismos para la segmentación visual. / Our visual perception typically includes segmentation of objects in a visual scene. However, the mechanisms that end up building these visual objects are unknown. Visual exploration involves various eye movements such fixations, saccades and microsaccades. We propose that the visual perception of an object is comprised by spatial clustering of microsaccades and correlates with the report of the perceived objects, independently of the size and dependent on objects shape. Here, we show that using a free viewing task, grouping patterns on microsaccades effectively correlate with perceived objects. Contrast saliency maps indicate that regions with a greater presence of microsaccades represent the perception of an object and not only areas that stand out from the image by its physical characteristics. The microsaccades grouping was independent of the objects perceived, maintaining the absolute size while scaling the stimulus images. Finally, we found that the spatial arrangement of microsaccades is depended on the shape of the reported objects, adopting a biased shape according to the nature of the objects. These results can contribute to the characterization of the perception of objects in a scene and shed light on the mechanisms for visual segmentation.
6

Red blood cell (RBC) - Teste de hemolise: uma alternativa ao teste de Draize-irritacao ocular na avaliacao do poder toxico de produtos cosmeticos no controle de qualidade

Alves, Eloisa Nunes. January 2003 (has links)
Mestre -- Instituto Nacional de Controle de Qualidade em Saude, Rio de Janeiro, 2003.
7

Estrategias de reconocimiento visual en la percepción del movimiento biológico : exploración visual libre o fijación visual forzada

González Galleguillos, Diego Mauricio January 2018 (has links)
Grado de magíster en neurociencias / Uno de los movimientos complejos con importancia evolutiva en humanos es el movimiento biológico, definido como un conjunto de puntos de alto contraste que siguen un patrón coherente de movimiento y que involucra un nivel de procesamiento complejo que integra la velocidad, la forma de los objetos en movimiento, interpretando acciones, estímulos sociales y emociones. Se proponen tres hipótesis para entender qué estrategias visuales permiten la percepción del movimiento biológico. Por una parte, a través de un seguimiento ocular continuo que explora el movimiento biológico (“por partes”), por otra, a través de un foco de atención local discontinuo que extrapola la percepción del movimiento biológico sin explorarlo (“un todo”) y una última que integra ambas hipótesis. Estas hipótesis plantean vías de procesamiento en dos fases: la primera de movimientos locales que se integran en regiones corticales sensoriales de fragmentos del cuerpo. Y la segunda, de fragmentos que generan representaciones completas en la corteza multimodal. Existe actualmente una discusión abierta acerca de cuál de estas estrategias es prioritaria para la percepción del movimiento biológico. Para ello se determinó qué estrategias de reconocimiento visual son usadas preferentemente para la percepción del MB observando si existen diferencias en el desempeño conductual de la percepción visual del MB, durante la exploración libre comparada con la fijación forzada de un objetivo mediante el uso de un sistema de seguimiento ocular (“eye tracker”). Según hallazgos de este estudio se puede afirmar que en la muestra evaluada para un mejor desempeño de la percepción del movimiento biológico es necesario el uso de estrategias de exploración visual libre, y esta conducta ocular obedece a lugares estratégicos del movimiento biológico según la valencia de este. Estudios futuros de este paradigma podrían incluir registro de actividad de señales corticales como el uso de EEG, tanto en sujetos sanos como en personas con patologías que afecten la percepción de esta tarea, como en pacientes con esquizofrenia. / One of the complex movements with evolutionary importance in humans is the biological movement, defined as a set of high-contrast points that follow a coherent pattern of motion and involve a complex processing level that integrates speed the form of moving objects, interpreting actions, social stimuli and emotions. Three hypotheses are proposed to understand visual strategies allow the perception of biological movement. On the one hand, through follow-up continuous ocular that explores the biological movement ("by parts"). On the other, to through a discontinuous local focus of attention that extrapolates the perception of biological movement without exploring it ("a whole"). And a last one that integrates both hypothesis these hypotheses are ways of processing in two phases: The first of local movements which are integrated into sensory cortical regions of fragments of the body. The second of fragments generate by complete representations in multimodal crust. There is currently an open discussion about which of these strategies is a priority for the perception of biological movement. For this, it was determined which visual recognition strategies are used preferentially for MB perception by observing if there are differences in behavioral performance of MB visual perception. During the scan-free compared with forced fixation of a target by using an ocular tracking system (eye tracker). According to findings of this study it can be said that use sample evaluated for a better performance of the perception of biological movement It is necessary to use free visual scanning strategies, and this ocular behavior is due to strategic location of biological movement according to the valence of this. Future studies of this paradigm could include recording activity of cortical signals such as the use of EEG, Both in healthy subject as in people with pathologies that affect the perception of this task as in patients with schizophrenia.
8

Estudo da aplicabilidade do ensaio de quantificação de proteínas totais em células SIRC na avaliação do potencial de irritação ocular de xampus e tensoativos / Study of the applicability of the essay of total proteins in cells SIRC in the evaluation of the potential of ocular irritant of shampoos and surfactants

Costa, Rodrigo Netto January 2006 (has links)
Made available in DSpace on 2012-09-06T01:11:49Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 822.pdf: 597896 bytes, checksum: 6a13eb480467828f067971a5bd0ceeb1 (MD5) Previous issue date: 2006 / A crescente tendência mundial pela substituição do uso de animais em experimentação promoveu a busca por métodos alternativos. Particular ênfase é dada ao desenvolvimento de métodos para substituir o tradicional Teste de Draize, utilizado para acessar a irritação ocular. Este teste tem sido um dos mais criticados pela comunidade científica, principalmente devido à subjetividade de avaliação das lesões oculares e variabilidade dos resultados obtidos em diferentes laboratórios, além das questões éticas com relação ao bem-estar animal. No presente estudo, o ensaio de quantificação de proteínas totais utilizando o corante Azul Brilhante de Coomassie R-250 foi avaliado quanto ao seu valor em predizer o potencial de irritação ocular de vinte xampus e cinco tensoativos. Para este ensaio de citotoxicidade, utilizou-se à linhagem celular derivada de córnea de coelho (SIRC). (...) Apesar de haver a necessidade de se testar um maior número de produtos e da realização de estudos inter-laboratoriais para se acessar a reprodutibilidade desta metodologia; com os resultados obtidos no presente estudo pode-se dizer que o ensaio de quantificação de proteínas totais utilizando o corante Azul Brilhante de Coomassie R-250, além de ser um método com características importantes como rapidez, sensibilidade, simplicidade de execução, baixo custo e alto grau de automação, foi capaz de predizer o potencial de irritação ocular de xampus e tensoativos
9

Alterações clínicas e oculares em cães naturalmente infectados por Leishmania infantum

Cunha, Caroline Magalhães January 2015 (has links)
Submitted by Angelo Silva (asilva@icict.fiocruz.br) on 2016-07-13T18:48:18Z No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 71844.pdf: 6374317 bytes, checksum: cbcb33e3210240d51e2f525530467e5c (MD5) / Approved for entry into archive by Anderson Silva (avargas@icict.fiocruz.br) on 2016-08-24T19:30:58Z (GMT) No. of bitstreams: 2 71844.pdf: 6374317 bytes, checksum: cbcb33e3210240d51e2f525530467e5c (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) / Made available in DSpace on 2016-08-24T19:30:58Z (GMT). No. of bitstreams: 2 71844.pdf: 6374317 bytes, checksum: cbcb33e3210240d51e2f525530467e5c (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2015 / Fundação Oswaldo Cruz. Instituto Oswaldo Cruz. Rio de Janeiro, RJ, Brasil / Os achados clínicos da leishmaniose visceral canina (LVC), assim como os da leishmaniose visceral humana (LVH) são variáveis e inespecíficos. Apesar da LVC se apresentar como uma doença que pode ser fatal e crônica, existem poucos estudos descrevendo as alterações clínicas e histopatológicas destas infecções. Desta forma, evidenciando a necessidade de obtenção de dados que pudessem contribuir nesses estudos, o objetivo deste trabalho foi estudar as alterações clínicas e oculares presentes em 25 cães com leishmaniose visceral provenientes da localidade Cidade Operária, São Luís - Maranhão/Brasil através da realização de avaliação clínica, testes oftalmológicos (Schirmer e colírio fluoresceína) além de dosagens hematológicas e bioquímicas, isolamento e caracterização do parasito em amostras de medula óssea, baço e humor aquoso, além de PCR. Os resultados mostraram que linfoadenopatia foi o sintoma mais frequente, seguido de caquexia, alopecia, lesão de pele, onicogrifose e hepatoesplenomegalia. As manifestações clínicas oculares observadas com maior frequência foram: presença de algum tipo de secreção e conjuntivite, seguido de blefarite, uveíte e opacidade de córnea. Oito animais foram positivos no teste de Schirmer e sete no colírio de fluoresceína indicando a presença de ceratoconjuntivite seca e úlcera de cornea, respectivamente As alterações hematológicas mais frequentes foram anemia e trombocitopenia, aumento sérico de proteínas totais e globulina e a diminuição de albumina. A alteração mais frequente observada em todos os animais foi a presença de infiltrado inflamatório do tipo plasmocitário. A análise histopatológica dos olhos dos cães mostrou lesões nas pálpebras, esclera, glândulas e musculatura retrorbital. Tendo a presença do parasito sido evidenciada em 16% dos animais. Estes resultados mostram que as manifestações oftalmológicas estão presentes em animais com LVC e podem ocorrer concomitantemente com outros sinais sistêmicos da doença. É importante considerar a leishmaniose como uma doença sistêmica, a qual afeta diferentes órgãos e sistemas. Sugerimos assim, que em áreas endêmicas, este agravo deve ser incluído como diagnóstico diferencial de cães com lesões oculares ou de etiologia desconhecida / Abstract: Clinical findings of canine visceral leishmaniasis (CVL), as well as of human visceral leishmaniasis (HVL) are variable and nonspecific. Although VC present as a disease that can be fatal and chronic few studies describing the clinical and histopathological changes of these infections. Thus, highlighting the need to obtain data that could contribute to these studies, the objective of this work was to study the clinical and ocular abnormalities present in 25 dogs with visceral leishmaniasis from the locality City Workers, Sao Luis - Maranhao / Brazil by conducting clinical, ophthalmological test (fluorescein drops and Schirmer) and hematological and biochemical measurements, isolation and characterization of the parasite in samples of bone marrow, spleen, and aqueous humor, and PCR. The results showed that lymphadenopathy was the most common symptom, followed by cachexia, alopecia, skin lesion, onychogryphosis, and hepatosplenomegaly. Ocular clinical manifestations observed most frequently were the presence of some type of secretion and conjunctivitis, followed by blepharitis, uveitis and corneal opacity. Eight animals were positive in the Schirmer test and seven in drops of fluorescein indicating the presence of keratoconjunctivitis sicca and cornea ulcer, respectively The most common hematologic abnormalities were anemia and thrombocytopenia, increased serum total protein and globulin and decreased albumin. The most frequent alteration observed in all animals was the presence of inflammatory infiltrate of plasma cell type. Histopathological analysis dogs eyes showed lesions on the eyelids, sclera, glands and muscles retrorbital. Since the presence of the parasite was observed in 16% of animals. These results show that the ocular manifestations are present in animals with LVC and can occur concurrently with other signs of systemic illness. It is important to consider leishmaniasis as a systemic disease, which affects different organs and systems. We suggest therefore that in endemic areas, this grievance should be included in the differential diagnosis of dogs with eye injuries or of unknown etiology
10

Avaliação da Reatividade de Anticorpos Anti-toxoplasma gondii pela Técnica de Citometria de Fluxo Como indicadores de Lesão Ocular em Soros de Recémnascidos com Toxoplasmose Congênita

JESUS, L. N. N. P. 05 December 2014 (has links)
Made available in DSpace on 2016-08-29T15:34:59Z (GMT). No. of bitstreams: 1 tese_8372_Dissertação Laura Néspoli.pdf: 1629298 bytes, checksum: 4f06298ca89a21aa7b5c0cf540d13579 (MD5) Previous issue date: 2014-12-05 / A retinocoroidite é a manifestação mais comum causada pela infecção congênita por Toxoplasma gondii. Devido a gravidade das lesões oculares que podem até levar à perda completa da visão, a detecção precoce da toxoplasmose congênita e da lesão ocular são essenciais para o tratamento. Este trabalho possuiu o objetivo de avaliar a aplicabilidade da pesquisa de anticorpos IgG e das subclasses IgG1, IgG2, IgG3 e IgG4 anti-T. gondii por citometria de fluxo como marcador laboratorial das diferentes formas de lesões retinocoroidais na toxoplasmose congênita. Foram analisadas 88 amostras de soro de recém-nascidos com toxoplasmose congênita, sendo 25 sem lesão ocular (SL), 10 com lesão ocular ativa (RA), 26 com lesão ocular ativa e cicatricial (RAC) e 27 com lesão ocular cicatricial (RC). Foram também utilizadas 19 amostras de soro de recém-nascidos não infectados que apresentaram IgG positivo após o nascimento (NI). Essas amostras foram obtidas a partir de soros de recémnascidos participantes de um programa de triagem neonatal realizado em Minas Gerais realizado nos anos de 2006 e 2007. Os resultados demonstraram que os recém-nascidos com toxoplasmose congênita apresentam maior reatividade de anticorpos IgG total e subclasses IgG1, IgG2 e IgG3 do que indivíduos não infectados. No grupo não infectado, o único anticorpo com mais de 50% de indivíduos com alta reatividade de anticorpos foi IgG4. Ao comparar os grupos de indivíduos com toxoplasmose congênita, foi observado que o grupo RAC, seguido de RC, apresentou maior reatividade principalmente para os anticorpos IgG1 e IgG3 comparado aos recém-nascidos dos grupos RA e SL, enquanto que pacientes do grupo RA apresentaram maior reatividade para IgG4 do que indivíduos dos outros grupos. IgG1 foi a única subclasse capaz de diferenciar os grupos NI, SL dos grupos RAC e RC. Também foi avaliado o índice de avidez de IgG total, que não permitiu estabelecer nenhum critério de diferenciação das formas de lesão ocular causadas pelo T. gondii. Portanto, a citometria de fluxo demonstrou que pode ser um método laboratorial complementar para ser utilizado como indicador das diferentes lesões oculares causadas pela toxoplasmose congênita.

Page generated in 0.049 seconds