• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 87
  • 20
  • 5
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 158
  • 158
  • 31
  • 26
  • 22
  • 18
  • 18
  • 17
  • 16
  • 15
  • 15
  • 14
  • 13
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Modelling of wave impact on offshore structures /

Abdolmaleki, Kourosh. January 2007 (has links)
Thesis (Ph.D.)--University of Western Australia, 2007.
112

Instalação e capacidade de carga axial de estacas modelo fluidizadas em solos arenosos / Installation and axial load capacity of fluidized model piles in sandy soils

Passini, Larissa de Brum January 2015 (has links)
O objetivo desta tese foi verificar a viabilidade de utilização de jatos de água verticais circulares, únicos e contínuos, provenientes da ponteira de uma estaca torpedo, para auxiliar sua instalação por peso próprio no leito marinho, através da fluidização do solo. Foram realizados ensaios de laboratório, em modelo reduzido, utilizando hastes para simular estacas torpedo (sem aletas) seguindo a lei de semelhança pelo número de Froude. Os ensaios de instalação por peso próprio, com e sem fluidização, ocorreram sem altura de queda, com a estaca modelo em contato com a superfície do leito. Trabalhou-se com três diâmetros de estacas, seis massas, quatros vazões e areia fina saturada compactada em duas densidades relativas iniciais (média e densa). Os ensaios de arrancamento, em leito arenoso fluidizado e não fluidizado, foram realizados imediatamente, 4, 24 e 48 horas após a instalação dos modelos. A metodologia de instalação proposta mostrou-se viável, quando o jateamento é aplicado desde a superfície em solo arenoso. As profundidades instaladas atingidas por fluidização (L/de > 50) foram consideravelmente superiores às profundidades cravadas por apenas peso próprio (L/de < 5). A geometria da zona perturbada durante a instalação por fluidização dos modelos, permaneceu constante e paralela ao fuste, com geometria de aproximadamente 2de em relação ao modelo, independentemente da vazão aplicada e da densidade relativa inicial do solo. A partir das leis de análise dimensional, uma expressão para a profundidade instalada das estacas modelo foi proposta, mostrando que a mesma é função do peso e da geometria do modelo, das propriedades físicas do solo e do fluido, e de sua vazão. Quanto maior a massa do modelo e a vazão aplicada e menor a densidade relativa, maior a profundidade atingida e maior a velocidade inicial de instalação. Constatou-se que a capacidade de carga axial dos modelos depende da densidade relativa, do diâmetro do modelo e do método de instalação (com e sem fluidização). Independentemente da densidade relativa inicial, o solo fluidizado convergiu para a mesma densidade relativa final, próxima as suas condições no estado crítico. As estacas em solo fluidizado apresentaram ganho resistência com o tempo (efeito de setup), com capacidade de carga inferior às estacas cravadas em solo não fluidizado. / The aim of this thesis was to investigate the feasibility of using circular vertical water jets, single and continuous, from the tip of a torpedo pile, to assist its installation by own weight on the seabed, through soil fluidization. Laboratory model tests were carried out, using tubes to simulate torpedo piles (without wings) following the law of similarity defined by the Froude number. The installation tests by the pile own weight, with and without fluidization, occurred without drop height, with the piles in contact with the surface of the bed. Three diameters of model piles and six masses, four flow rates and saturated sand at two initial relative densities (medium and dense) have been used in this set of experiments. Pullout tests in fluidized and nonfluidized soils were performed immediately, 4, 24 and 48 hours after the installation of the models. The proposed installation methodology proved to be feasible when the fluidization is applied from the surface in sandy soils. The installation depths achieved by fluidization (L/de > 50) were significantly higher than the depths reached by pile own weight (L/de < 5). The geometry of the perturbed zone during model installation by fluidization remained constant and parallel to the shaft in a geometry of about 2de of the pile model, regardless of the applied flow rate and the initial relative density of the soil. Following the laws of dimensional analysis, an expression for the embedment of fluidized piles is derived, showing that the penetration depth is a function of pile weight and geometry, fluidized water jet flow rate and velocity, as well as the soil and fluid properties. Increasing the model mass and fluidized flow rate and decreasing the relative density leads to an increase in the depth reached and the initial speed of installation. The axial load capacity of the models depends on the soil relative density, piles diameter and installation method (with and without fluidization). Regardless the initial relative density, the fluidized soil converged to the same final relative density, near its conditions of critical state. Piles installed in fluidized soil presented gain of axial capacity over time (setup effect) with lower resistance than piles driven in nonfluidized soil.
113

Fluidização de solo arenoso associada à injeção de agente cimentante para ancoragem de estruturas offshore / Fluidisation of sandy soils associated to the injection of cementing agent for applying in offshore structures

Stracke, Fernanda January 2012 (has links)
A instalação de estruturas offshore em grandes profundidades demanda avanços na área da Engenharia, principalmente quanto ao desenvolvimento de novas tecnologias associadas à ancoragem destas estruturas. O objetivo deste trabalho é analisar os mecanismos e conceitos associados à fluidização de solos arenosos com jatos de água, associando a técnica ao melhoramento do solo com agente cimentante, com a finalidade de futuramente aplicar estas técnicas em campo, na instalação e fixação de fundações e âncoras para plataformas e estruturas offshore. O trabalho é fundamentado nas pesquisas de Niven (1998) e Mezzomo (2009). O estudo foi desenvolvido através de ensaios em laboratório, sendo os ensaios de fluidização executados em tanque de acrílico de 45 x 45 cm e altura de 110 cm. Foram realizados ensaios em areia fina de granulometria uniforme (d50 = 0,18 mm). Quanto aos ensaios de fluidização, foi avaliada a influência dos parâmetros do jato (vazão e velocidade) na geometria da zona fluidizada, verificando as equações empíricas para determinar a geometria da zona fluidizada através do número de Froude das partículas (Frp) - desenvolvidas por Mezzomo (2009) - e ampliando o banco de dados dos ensaios de fluidização. Foi avaliada a influência dos parâmetros do jato (vazão) e do solo (permeabilidade e diâmetro das partículas), sobre a profundidade crítica T3. Foi definida a relação entre a profundidade crítica T3 de ensaios executados no centro e na lateral do tanque de ensaios (T3centro/T3lateral = 0,5 a 0,8). Complementarmente, foram realizados ensaios de fluidização associados à injeção de agente cimentante, através dos quais foi possível compreender a forma geral de comportamento da injeção de agente cimentante em solos arenosos. Finalmente, foram executadas provas de carga estáticas à tração em solo arenoso fluidizado e não fluidizado, e em ensaios com injeção de calda de cimento. Através destes, verificou-se uma perda de capacidade de carga entre 30 e 50% devido à fluidização do solo. Além disso, a injeção de agente cimentante resultou em aumento da capacidade de carga entre 11 e 15 vezes, em relação aos ensaios sem injeção de agente cimentante. / The installation of offshore structures in deep water demands advances in Engineering, particularly for the development of new technologies associated with the anchor of these structures. The aim of this paper is to analyze the mechanisms and concepts associated with fluidization of sandy soils with water jets, combining the technique of improvement of the soil with cementing agent in order to implement these techniques in the field for installing and arrest offshore foundations and anchors of platforms and structures, in the future. The work is based on Niven (1998) and Mezzomo (2009) researches. The study was developed through laboratory tests designed for fluidization tests carried on into acrylic tank of dimensions 45 x 45 cm and height of 110 cm. The tests were performed with uniform fine sand (d50 = 0.18 mm). About fluidization tests the influence of jet parameters (rate and speed) on the geometry of fluidized zone was evaluated, verifying empirical equations to determine the geometry of the fluidized zone through the Froude number - developed by Mezzomo (2009) - expanding the database of fluidization tests. The influence of the jet and soil parameters (rate, permeability and d50) on critical depth (T3) was carefully investigated. The relation of critical depth of the tests ran in the center and side position in the tank was found to be from 0.5 to 0.8. In addition, fluidization tests associated with injection of cementing agent were carried out to improve the understanding of the general behavior of the injection of cementing agent (cement grout) in sandy soils. Finally, static tension load tests on fluidized and no fluidized sand were performed, complemented by tests with injection of cement grout. Through these, it was found that there is a 30 to 50% loss in load capacity due to the fluidization of the soil. Furthermore, tests with injection of cement agent resulted in increasing load capacity about 11 up to 15 times, in relation to the tests without cement agent injection.
114

Instalação e capacidade de carga axial de estacas modelo fluidizadas em solos arenosos / Installation and axial load capacity of fluidized model piles in sandy soils

Passini, Larissa de Brum January 2015 (has links)
O objetivo desta tese foi verificar a viabilidade de utilização de jatos de água verticais circulares, únicos e contínuos, provenientes da ponteira de uma estaca torpedo, para auxiliar sua instalação por peso próprio no leito marinho, através da fluidização do solo. Foram realizados ensaios de laboratório, em modelo reduzido, utilizando hastes para simular estacas torpedo (sem aletas) seguindo a lei de semelhança pelo número de Froude. Os ensaios de instalação por peso próprio, com e sem fluidização, ocorreram sem altura de queda, com a estaca modelo em contato com a superfície do leito. Trabalhou-se com três diâmetros de estacas, seis massas, quatros vazões e areia fina saturada compactada em duas densidades relativas iniciais (média e densa). Os ensaios de arrancamento, em leito arenoso fluidizado e não fluidizado, foram realizados imediatamente, 4, 24 e 48 horas após a instalação dos modelos. A metodologia de instalação proposta mostrou-se viável, quando o jateamento é aplicado desde a superfície em solo arenoso. As profundidades instaladas atingidas por fluidização (L/de > 50) foram consideravelmente superiores às profundidades cravadas por apenas peso próprio (L/de < 5). A geometria da zona perturbada durante a instalação por fluidização dos modelos, permaneceu constante e paralela ao fuste, com geometria de aproximadamente 2de em relação ao modelo, independentemente da vazão aplicada e da densidade relativa inicial do solo. A partir das leis de análise dimensional, uma expressão para a profundidade instalada das estacas modelo foi proposta, mostrando que a mesma é função do peso e da geometria do modelo, das propriedades físicas do solo e do fluido, e de sua vazão. Quanto maior a massa do modelo e a vazão aplicada e menor a densidade relativa, maior a profundidade atingida e maior a velocidade inicial de instalação. Constatou-se que a capacidade de carga axial dos modelos depende da densidade relativa, do diâmetro do modelo e do método de instalação (com e sem fluidização). Independentemente da densidade relativa inicial, o solo fluidizado convergiu para a mesma densidade relativa final, próxima as suas condições no estado crítico. As estacas em solo fluidizado apresentaram ganho resistência com o tempo (efeito de setup), com capacidade de carga inferior às estacas cravadas em solo não fluidizado. / The aim of this thesis was to investigate the feasibility of using circular vertical water jets, single and continuous, from the tip of a torpedo pile, to assist its installation by own weight on the seabed, through soil fluidization. Laboratory model tests were carried out, using tubes to simulate torpedo piles (without wings) following the law of similarity defined by the Froude number. The installation tests by the pile own weight, with and without fluidization, occurred without drop height, with the piles in contact with the surface of the bed. Three diameters of model piles and six masses, four flow rates and saturated sand at two initial relative densities (medium and dense) have been used in this set of experiments. Pullout tests in fluidized and nonfluidized soils were performed immediately, 4, 24 and 48 hours after the installation of the models. The proposed installation methodology proved to be feasible when the fluidization is applied from the surface in sandy soils. The installation depths achieved by fluidization (L/de > 50) were significantly higher than the depths reached by pile own weight (L/de < 5). The geometry of the perturbed zone during model installation by fluidization remained constant and parallel to the shaft in a geometry of about 2de of the pile model, regardless of the applied flow rate and the initial relative density of the soil. Following the laws of dimensional analysis, an expression for the embedment of fluidized piles is derived, showing that the penetration depth is a function of pile weight and geometry, fluidized water jet flow rate and velocity, as well as the soil and fluid properties. Increasing the model mass and fluidized flow rate and decreasing the relative density leads to an increase in the depth reached and the initial speed of installation. The axial load capacity of the models depends on the soil relative density, piles diameter and installation method (with and without fluidization). Regardless the initial relative density, the fluidized soil converged to the same final relative density, near its conditions of critical state. Piles installed in fluidized soil presented gain of axial capacity over time (setup effect) with lower resistance than piles driven in nonfluidized soil.
115

Fluidização de solo arenoso associada à injeção de agente cimentante para ancoragem de estruturas offshore / Fluidisation of sandy soils associated to the injection of cementing agent for applying in offshore structures

Stracke, Fernanda January 2012 (has links)
A instalação de estruturas offshore em grandes profundidades demanda avanços na área da Engenharia, principalmente quanto ao desenvolvimento de novas tecnologias associadas à ancoragem destas estruturas. O objetivo deste trabalho é analisar os mecanismos e conceitos associados à fluidização de solos arenosos com jatos de água, associando a técnica ao melhoramento do solo com agente cimentante, com a finalidade de futuramente aplicar estas técnicas em campo, na instalação e fixação de fundações e âncoras para plataformas e estruturas offshore. O trabalho é fundamentado nas pesquisas de Niven (1998) e Mezzomo (2009). O estudo foi desenvolvido através de ensaios em laboratório, sendo os ensaios de fluidização executados em tanque de acrílico de 45 x 45 cm e altura de 110 cm. Foram realizados ensaios em areia fina de granulometria uniforme (d50 = 0,18 mm). Quanto aos ensaios de fluidização, foi avaliada a influência dos parâmetros do jato (vazão e velocidade) na geometria da zona fluidizada, verificando as equações empíricas para determinar a geometria da zona fluidizada através do número de Froude das partículas (Frp) - desenvolvidas por Mezzomo (2009) - e ampliando o banco de dados dos ensaios de fluidização. Foi avaliada a influência dos parâmetros do jato (vazão) e do solo (permeabilidade e diâmetro das partículas), sobre a profundidade crítica T3. Foi definida a relação entre a profundidade crítica T3 de ensaios executados no centro e na lateral do tanque de ensaios (T3centro/T3lateral = 0,5 a 0,8). Complementarmente, foram realizados ensaios de fluidização associados à injeção de agente cimentante, através dos quais foi possível compreender a forma geral de comportamento da injeção de agente cimentante em solos arenosos. Finalmente, foram executadas provas de carga estáticas à tração em solo arenoso fluidizado e não fluidizado, e em ensaios com injeção de calda de cimento. Através destes, verificou-se uma perda de capacidade de carga entre 30 e 50% devido à fluidização do solo. Além disso, a injeção de agente cimentante resultou em aumento da capacidade de carga entre 11 e 15 vezes, em relação aos ensaios sem injeção de agente cimentante. / The installation of offshore structures in deep water demands advances in Engineering, particularly for the development of new technologies associated with the anchor of these structures. The aim of this paper is to analyze the mechanisms and concepts associated with fluidization of sandy soils with water jets, combining the technique of improvement of the soil with cementing agent in order to implement these techniques in the field for installing and arrest offshore foundations and anchors of platforms and structures, in the future. The work is based on Niven (1998) and Mezzomo (2009) researches. The study was developed through laboratory tests designed for fluidization tests carried on into acrylic tank of dimensions 45 x 45 cm and height of 110 cm. The tests were performed with uniform fine sand (d50 = 0.18 mm). About fluidization tests the influence of jet parameters (rate and speed) on the geometry of fluidized zone was evaluated, verifying empirical equations to determine the geometry of the fluidized zone through the Froude number - developed by Mezzomo (2009) - expanding the database of fluidization tests. The influence of the jet and soil parameters (rate, permeability and d50) on critical depth (T3) was carefully investigated. The relation of critical depth of the tests ran in the center and side position in the tank was found to be from 0.5 to 0.8. In addition, fluidization tests associated with injection of cementing agent were carried out to improve the understanding of the general behavior of the injection of cementing agent (cement grout) in sandy soils. Finally, static tension load tests on fluidized and no fluidized sand were performed, complemented by tests with injection of cement grout. Through these, it was found that there is a 30 to 50% loss in load capacity due to the fluidization of the soil. Furthermore, tests with injection of cement agent resulted in increasing load capacity about 11 up to 15 times, in relation to the tests without cement agent injection.
116

Análise numérica de fenômenos de impacto hidrodinâmico em plataformas offshore. / Numerical analysis of hydrodynamic impact phenomena on offshore platforms.

Cezar Augusto Bellezi 19 November 2014 (has links)
O presente trabalho é focado no estudo dos violentos fenômenos de impacto hidrodinâmico que podem prejudicar a operação de plataformas offshore. São três os fenômenos abordados neste trabalho: o green water, o wave runup e o sloshing. O fenômeno de wave runup consiste na projeção vertical de uma coluna de água devido ao impacto de ondas em estruturas transversais. O fenômeno de green water consiste no embarque de água no convés, podendo danificar os equipamentos da planta de produção. Por fim, o sloshing consiste no movimento violento de fluído em tanques parcialmente preenchidos, resultando em perigosos carregamentos em suas paredes. Tais fenômenos possuem natureza altamente não linear e sua análise, considerando-se toda a sua complexidade, ainda constitui um desafio para a engenharia naval e oceânica. Os métodos de partículas têm se destacado no tratamento de tais fenômenos envolvendo interação fluído-estruturas, grandes deformações e fragmentação de superfície livre. Desta maneira, optou-se pelo emprego do método de partículas Moving Particles Semi-Implicit (MPS) neste trabalho para o estudo dos fenômenos de impacto hidrodinâmico. O MPS é um método totalmente lagrangeano para escoamentos incompressíveis. Para os três fenômenos abordados neste trabalho há uma primeira etapa de validação, na qual os resultados numéricos são comparados a resultados experimentais da literatura. Uma segunda etapa é baseada na aplicação do método numérico na análise de ferramentas para a mitigação dos esforços resultantes do impacto hidrodinâmico. Nesta etapa é investigada a influência do formato da proa no fenômeno de green water e a utilização de anteparas fixas e flutuantes para a mitigação de sloshing em tanques. / The present work is focused in the study of the violent hydrodynamic impact phenomenon which could jeopardize the offshore platforms operation. In this work three different phenomena involving hydrodynamic impact are studied: green water, wave runup and sloshing. The wave runup consists in the vertical projection of a water column due to wave impact on a transversal structure, such as submersible columns. The green water consists in the water boarding on the deck which could damage the equipment over the oil platform deck. Finally, the sloshing phenomenon is the violent movement of fluid in partially filled tanks, resulting in dangerous impact loads at its walls. The hydrodynamic impact phenomenon has strongly non linear nature and is still a challenge for the naval and offshore engineering its analysis considering all its complexity. The particle methods present advantages in the analysis of phenomena involving fluid structure interaction, large free surface deformation, fragmentation and merging. Therefore, in the present study the Moving Particles Semi-Implicit (MPS) method is used. The MPS is a fully lagrangian method for the simulation of incompressible flows. For the three phenomena studied in the present work a first step of validation is performed. In the validation step the numerical results obtained by the particle method are compared to experimental data presented in the literature. The second step consists in the application of the numerical method to investigate simple mechanisms to mitigate the hydrodynamic impact loads. For example, the effect of the bow shape in the green water phenomenon is studied. Also in this step the use of fixed and floating baffles in order to suppress the sloshing phenomenon are investigated.
117

Instalação e capacidade de carga axial de estacas modelo fluidizadas em solos arenosos / Installation and axial load capacity of fluidized model piles in sandy soils

Passini, Larissa de Brum January 2015 (has links)
O objetivo desta tese foi verificar a viabilidade de utilização de jatos de água verticais circulares, únicos e contínuos, provenientes da ponteira de uma estaca torpedo, para auxiliar sua instalação por peso próprio no leito marinho, através da fluidização do solo. Foram realizados ensaios de laboratório, em modelo reduzido, utilizando hastes para simular estacas torpedo (sem aletas) seguindo a lei de semelhança pelo número de Froude. Os ensaios de instalação por peso próprio, com e sem fluidização, ocorreram sem altura de queda, com a estaca modelo em contato com a superfície do leito. Trabalhou-se com três diâmetros de estacas, seis massas, quatros vazões e areia fina saturada compactada em duas densidades relativas iniciais (média e densa). Os ensaios de arrancamento, em leito arenoso fluidizado e não fluidizado, foram realizados imediatamente, 4, 24 e 48 horas após a instalação dos modelos. A metodologia de instalação proposta mostrou-se viável, quando o jateamento é aplicado desde a superfície em solo arenoso. As profundidades instaladas atingidas por fluidização (L/de > 50) foram consideravelmente superiores às profundidades cravadas por apenas peso próprio (L/de < 5). A geometria da zona perturbada durante a instalação por fluidização dos modelos, permaneceu constante e paralela ao fuste, com geometria de aproximadamente 2de em relação ao modelo, independentemente da vazão aplicada e da densidade relativa inicial do solo. A partir das leis de análise dimensional, uma expressão para a profundidade instalada das estacas modelo foi proposta, mostrando que a mesma é função do peso e da geometria do modelo, das propriedades físicas do solo e do fluido, e de sua vazão. Quanto maior a massa do modelo e a vazão aplicada e menor a densidade relativa, maior a profundidade atingida e maior a velocidade inicial de instalação. Constatou-se que a capacidade de carga axial dos modelos depende da densidade relativa, do diâmetro do modelo e do método de instalação (com e sem fluidização). Independentemente da densidade relativa inicial, o solo fluidizado convergiu para a mesma densidade relativa final, próxima as suas condições no estado crítico. As estacas em solo fluidizado apresentaram ganho resistência com o tempo (efeito de setup), com capacidade de carga inferior às estacas cravadas em solo não fluidizado. / The aim of this thesis was to investigate the feasibility of using circular vertical water jets, single and continuous, from the tip of a torpedo pile, to assist its installation by own weight on the seabed, through soil fluidization. Laboratory model tests were carried out, using tubes to simulate torpedo piles (without wings) following the law of similarity defined by the Froude number. The installation tests by the pile own weight, with and without fluidization, occurred without drop height, with the piles in contact with the surface of the bed. Three diameters of model piles and six masses, four flow rates and saturated sand at two initial relative densities (medium and dense) have been used in this set of experiments. Pullout tests in fluidized and nonfluidized soils were performed immediately, 4, 24 and 48 hours after the installation of the models. The proposed installation methodology proved to be feasible when the fluidization is applied from the surface in sandy soils. The installation depths achieved by fluidization (L/de > 50) were significantly higher than the depths reached by pile own weight (L/de < 5). The geometry of the perturbed zone during model installation by fluidization remained constant and parallel to the shaft in a geometry of about 2de of the pile model, regardless of the applied flow rate and the initial relative density of the soil. Following the laws of dimensional analysis, an expression for the embedment of fluidized piles is derived, showing that the penetration depth is a function of pile weight and geometry, fluidized water jet flow rate and velocity, as well as the soil and fluid properties. Increasing the model mass and fluidized flow rate and decreasing the relative density leads to an increase in the depth reached and the initial speed of installation. The axial load capacity of the models depends on the soil relative density, piles diameter and installation method (with and without fluidization). Regardless the initial relative density, the fluidized soil converged to the same final relative density, near its conditions of critical state. Piles installed in fluidized soil presented gain of axial capacity over time (setup effect) with lower resistance than piles driven in nonfluidized soil.
118

Fluidização de solo arenoso associada à injeção de agente cimentante para ancoragem de estruturas offshore / Fluidisation of sandy soils associated to the injection of cementing agent for applying in offshore structures

Stracke, Fernanda January 2012 (has links)
A instalação de estruturas offshore em grandes profundidades demanda avanços na área da Engenharia, principalmente quanto ao desenvolvimento de novas tecnologias associadas à ancoragem destas estruturas. O objetivo deste trabalho é analisar os mecanismos e conceitos associados à fluidização de solos arenosos com jatos de água, associando a técnica ao melhoramento do solo com agente cimentante, com a finalidade de futuramente aplicar estas técnicas em campo, na instalação e fixação de fundações e âncoras para plataformas e estruturas offshore. O trabalho é fundamentado nas pesquisas de Niven (1998) e Mezzomo (2009). O estudo foi desenvolvido através de ensaios em laboratório, sendo os ensaios de fluidização executados em tanque de acrílico de 45 x 45 cm e altura de 110 cm. Foram realizados ensaios em areia fina de granulometria uniforme (d50 = 0,18 mm). Quanto aos ensaios de fluidização, foi avaliada a influência dos parâmetros do jato (vazão e velocidade) na geometria da zona fluidizada, verificando as equações empíricas para determinar a geometria da zona fluidizada através do número de Froude das partículas (Frp) - desenvolvidas por Mezzomo (2009) - e ampliando o banco de dados dos ensaios de fluidização. Foi avaliada a influência dos parâmetros do jato (vazão) e do solo (permeabilidade e diâmetro das partículas), sobre a profundidade crítica T3. Foi definida a relação entre a profundidade crítica T3 de ensaios executados no centro e na lateral do tanque de ensaios (T3centro/T3lateral = 0,5 a 0,8). Complementarmente, foram realizados ensaios de fluidização associados à injeção de agente cimentante, através dos quais foi possível compreender a forma geral de comportamento da injeção de agente cimentante em solos arenosos. Finalmente, foram executadas provas de carga estáticas à tração em solo arenoso fluidizado e não fluidizado, e em ensaios com injeção de calda de cimento. Através destes, verificou-se uma perda de capacidade de carga entre 30 e 50% devido à fluidização do solo. Além disso, a injeção de agente cimentante resultou em aumento da capacidade de carga entre 11 e 15 vezes, em relação aos ensaios sem injeção de agente cimentante. / The installation of offshore structures in deep water demands advances in Engineering, particularly for the development of new technologies associated with the anchor of these structures. The aim of this paper is to analyze the mechanisms and concepts associated with fluidization of sandy soils with water jets, combining the technique of improvement of the soil with cementing agent in order to implement these techniques in the field for installing and arrest offshore foundations and anchors of platforms and structures, in the future. The work is based on Niven (1998) and Mezzomo (2009) researches. The study was developed through laboratory tests designed for fluidization tests carried on into acrylic tank of dimensions 45 x 45 cm and height of 110 cm. The tests were performed with uniform fine sand (d50 = 0.18 mm). About fluidization tests the influence of jet parameters (rate and speed) on the geometry of fluidized zone was evaluated, verifying empirical equations to determine the geometry of the fluidized zone through the Froude number - developed by Mezzomo (2009) - expanding the database of fluidization tests. The influence of the jet and soil parameters (rate, permeability and d50) on critical depth (T3) was carefully investigated. The relation of critical depth of the tests ran in the center and side position in the tank was found to be from 0.5 to 0.8. In addition, fluidization tests associated with injection of cementing agent were carried out to improve the understanding of the general behavior of the injection of cementing agent (cement grout) in sandy soils. Finally, static tension load tests on fluidized and no fluidized sand were performed, complemented by tests with injection of cement grout. Through these, it was found that there is a 30 to 50% loss in load capacity due to the fluidization of the soil. Furthermore, tests with injection of cement agent resulted in increasing load capacity about 11 up to 15 times, in relation to the tests without cement agent injection.
119

Estudo experimental de um supressor de vibração PTMD em um modelo reduzido de jumper submerso / Experimental study of a PTMD vibration absorber in a scaled down submarine jumper model

Tochetto, Luan Grégori, 1989- 23 August 2018 (has links)
Orientador: Sérgio Nascimento Bordalo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica e Instituto de Geociências / Made available in DSpace on 2018-08-23T18:52:37Z (GMT). No. of bitstreams: 1 Tochetto_LuanGregori_M.pdf: 7430018 bytes, checksum: 8523efb2c0601ab21d1e2057f0d7c2af (MD5) Previous issue date: 2013 / Resumo: Tubulações submarinas, tais como risers e jumpers, sofrem carregamentos estáticos e dinâmicos devido a forças ambientais, correntes marítimas e ondas, carregamentos devido aos deslocamentos da unidade flutuante de produção (plataformas ou navios), escoamento interno, além de outras causas. O controle dos deslocamentos oscilatórios dessas tubulações é fundamental para a confiabilidade e vida em fadiga desses sistemas, motivando projetos de pesquisa com tal propósito nos últimos anos. Uma tecnologia em consideração é o Pounding Tuned Mass Damper (PTMD), o qual é o assunto do presente trabalho. Este trabalho apresenta um estudo experimental de um absorvedor de vibrações - o PTMD - acoplado a um modelo de jumper submarino em escala reduzida. O aparato é composto de uma seção de tubo montada em um sistema de suspensão elástica para movimento em duas direções, propiciando similaridade dinâmica parcial entre o protótipo e o modelo. O modelo de PTMD é um sistema massa - mola anexado, similar a um supressor tuned mass damper (TMD), a não ser a adição de um envoltório de batimento, o qual limita o deslocamento da massa do PTMD, dissipando energia do tubo oscilante através do impacto da massa do PTMD contra esse envoltório. Experimentos de oscilação livre e forçada foram realizados na direção vertical, no seco e na água. Os resultados obtidos de amplitude versus frequência foram utilização para determinar a eficácia do absorvedor quando comparado com sua operação a seco. Os resultados deste trabalho são os primeiros passos no desenvolvimento de um dispositivo aplicável a uma real tubulação submarina de petróleo. Os dados adquiridos neste trabalho foram empregados na melhoria e desenvolvimento de um modelo numérico do sistema tubo - PTMD para um simulador computacional / Abstract: Submarine pipelines, such as jumpers and risers, suffer static and dynamic loads due to environmental forces - currents and waves, to the displacements of floating production units (platforms or ships) and to the internal flow, among other causes. Controlling the oscillatory displacements of the pipelines is critical to the reliability and fatigue of these systems, motivating research projects to deal with such issues in the past few years. One technology under consideration is the Pounding Tuned Mass Damper (PTMD), which is the subject of the present work. The current work presents an experimental study of a vibration suppressor - the PTMD - attached to a scaled down submarine jumper model. The apparatus is composed of a test pipe section mounted on an elastic suspension harness for two directions of motion, providing partial dynamic similarity between the prototype and the model. The PTMD model is a lumped mass-spring attachment similar to a tuned mass dumper (TMD) suppressor, but with the addition of a pounding layer, which limits the motion of the PTMD mass, dissipating the energy of the oscillating pipe through the impact of the PTMD mass against that layer. So far, free and forced oscillation experiments were executed, in the vertical direction. The tests were conducted in a water tank, where comparisons of amplitude versus frequency were made to determine the suppressor effectiveness, on air and underwater. The results of this work are the preliminary step on the development of a device applicable to an actual petroleum submarine pipeline. The data gathered from this work was employed in the improvement of a numerical model of the pipe-PTMD system for a computer simulator / Mestrado / Explotação / Mestre em Ciências e Engenharia de Petróleo
120

Hydrodynamics and risk analysis of iceberg impacts with offshore structures

McTaggart, Kevin Andrew January 1989 (has links)
The evaluation of design iceberg impact loads for offshore structures and the influence of hydrodynamic effects on impact loads are examined. Important hydrodynamic effects include iceberg added mass, wave-induced oscillatory iceberg motions, and the influence of a large structure on the surrounding flow field and subsequent velocities of approaching icebergs. The significance of these phenomena has been investigated using a two-body numerical diffraction model and through a series of experiments modelling the drift of various sized icebergs driven by waves and currents approaching a large offshore structure. Relevant findings from the hydrodynamic studies have been incorporated into two probabilistic models which can be used to determine design iceberg collision events with a structure based on either iceberg kinetic energy upon impact or global sliding force acting on the structure. Load exceedence probabilities from the kinetic energy and sliding force models are evaluated using the second-order reliability method. Output from the probabilistic models can be used to determine design collision parameters and to assess whether more sophisticated modelling of various impact processes is required. The influence of the structure on velocities of approaching icebergs is shown to be significant when the structure horizontal dimension is greater than twice the iceberg dimension. As expected, wave-induced oscillatory motions dominate the collision velocity for smaller icebergs but have a negligible effect on velocity for larger icebergs. / Applied Science, Faculty of / Civil Engineering, Department of / Graduate

Page generated in 0.1051 seconds