• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 984
  • 34
  • 34
  • 34
  • 34
  • 29
  • 29
  • 18
  • 14
  • 14
  • 6
  • 4
  • 1
  • 1
  • Tagged with
  • 1004
  • 450
  • 288
  • 190
  • 188
  • 167
  • 158
  • 156
  • 150
  • 145
  • 127
  • 111
  • 106
  • 94
  • 93
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Avaliação do sistema de forças tridimensionais produzido em mecânicas de intrusão, utilizando dobras verticais, alça retangular e arco contínuo /

Shintcovsk, Ricardo Lima. January 2017 (has links)
Orientador: Lídia Parsekian Martins / Resumo: Objetivo: Avaliar o sistema de forças tridimensionais, produzido em mecânicas de itrusão, utilizando dobras verticais, alça retangular e arco contínuo. Materiais e Métodos: Três artigos científicos foram redigidos e utilizados para a avaliação dos propósitos apresentados. Resultados: Na intrusão de incisivos os fios dos 3 grupos utilizados produziram forças e momentos diferentes. As maiores forças e momentos ocorreram no grupo SS. Forças linguais estavam presentes e foram significantes somente no grupo SS. No sentido mésio-distal o grupo Aço Inoxidável e o Flexy Multi produziram força distal. Os três grupos produziram momentos diferentes, todos com tendência de angulação do lateral no sentido distal, inclinação vestibular de coroa e rotação de mesial para vestibular. Em relação a intrusão pura do segundo molar (2M), durante a desativação houve diferenças significante entre os M(x) e F(x) produzidos pelas alças retangulares (AR) e pelo arco continuo (AC). No tubo do 2M, as AR produziram M(x) baixos e relativamente constantes durante a desativação enquanto que no AC eles foram de maior magnitude decrescendo linearmente. Quando o tubo do 2M foi inclinado mesialmente, houve diferença entre os M(x) produzidos na AR em relação ao AC, sendo que em AC estes momentos foram baixos. Já quando o dente foi inclinado para distal o AR produziu um M(x) menor em relação ao AC, bem como F(z) menores. Em todos os grupos analisados foram produzidos M(x) e F(z) altas nos primeiros molares. Conc... (Resumo completo, clicar acesso eletrônico abaixo) / To evaluate the system of forces produced in intrusion mechanics, in situations with mesial and distal supports to the bracket to be moved and without distal support. Materials and Methods: Three scientific articles were written and used to evaluate the purposes presented. Results: In the intrusion of incisors the wires of the 3 groups used produced different forces and moments. The greatest forces and moments occurred in the Stainless Steel group. Lingual forces were present and were significant only in the SS group. In the mesio-distal direction the stainless steel and the Flexy Multi groups produced distal force. The three groups produced different moments, all with tendencies of lateral angulation in the distal direction, buccal crown inclination and mesial rotation for vestibular. In relation to the pure intrusion of the second molar (2M), during the deactivation there were significant differences between the M(x) and F(x) produced by the rectangular (AR) and continuous arc (AC) loops. In the 2M tube, the ARs produced low and relatively constant M(x) during the deactivation while in the AC they were of larger magnitude decreasing linearly. When the 2M tube was inclined mesially, there was a difference between the M(x) produced in the RA in relation to the CA, and in AC these moments were low. When the tooth was tilted to distal, the AR produced a smaller M(x) in relation to the AC, as well as smaller F(z). In all groups analyzed, high M(x) and F(z) were produced in the first molars. Conclusion: When the intrusion bend is performed on a tooth with mesial and distal bracket support, the side effects are minimized. Beta-titanium and beta-titanium alloys coated with nickel-titanium had the best results compared to stainless steel. However, when we do not have the distal support, as in the case of the second molar, and if we want to perform (complete abstract elçectronic access below) / Doutor
132

Avaliação de reabsorções radiculares apicais externas decorrentes de movimentação ortodôntica em radiografias periapicais com registro a posteriori /

Kreich, Eliane Maria. January 2012 (has links)
Orientador: Luiz Cesar de Moraes / Banca: Juliana Campos Junqueira / Banca: Jefferson Luis Oshiro Tanaka / Banca: Ulisses Coelho / Banca: Maria Aparecida Neves Jardini / Resumo: O objetivo deste estudo foi quantificar a reabsorção radicular apical externa em indivíduos submetidos a tratamento ortodôntico e correlacionar a reabsorção radicular com possíveis fatores predisponentes. A amostra incluiu 79 indivíduos, com idade média de 13,7 anos e dividida em 2 grupos, de indivíduos tratados sem e com exodontia dos primeiros pré-molares superiores. Foram selecionadas as radiografias periapicais dos incisivos centrais superiores, obtidas no início e no final do tratamento ortodôntico. As radiografias foram digitalizadas e inseridas no programa Regeemy® - Image Registration and Mosaicking v.0.2.43-RCB (DPI-INPE, São José dos Campos, SP, Brazil) e procedidos os registros a posteriori (correção de diferenças de projeção geométrica, densidade e contraste entre as duas radiografias). As mensurações dos incisivos centrais superiores, foram realizadas nas imagens referência (pré tratamento) e na versão registrada (pós-tratamento), no programa UTHSCSA Image Tool® (University of Texas Health Science Center at San Antonio), obtidas em pixels e convertidas em porcentagem. Os resultados mostraram que ocorreu reabsorção radicular estatisticamente significante em ambos os grupos, com maior reabsorção no grupo com exodontia (p<0,05). Na comparação das variáveis pré e pós tratamento ortodôntico, entre os dois grupos, verificou-se que a diferença das medidas cefalométricas 1.NA e 1-NA foi significantemente maior no grupo com exodontia (p<0,05). A variável idade não diferiu estatisticamente entre os grupos (p>0,05). O período do tratamento foi significantemente maior no grupo com exodontia e as reabsorções radiculares foram também maiores no grupo tratado com exodontias (p<0,05), embora este resultado tenha sido estatisticamente significante apenas para o dente 11. Somente houve... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim on this study was to quantify the external apical root resorption in individuals submitted to orthodontic treatment and to correlate the root resorption with the possible predisposing factors. The sample comprised 79 individuals (mean age 13,7 years) divided into two groups: individuals treated with and without extractions of the maxillary first premolars. Periapical radiographs of maxillary central incisors obtained in the beginning and in the end of the orthodontic treatment were selected. The radiographs were digitized and imported to Regeemy® - Image Registration and Mosaicking v.0.2.43-RCB (DPI-INPE, São José dos Campos, SP, Brazil) for image registration a posteriori (correction of geometric, density and contrast differences between two images). The maxillary central incisors were measured in the reference (pre-treatment) and registered (post treatment) images using UTHSCSA Image Tool® (University of Texas Health Science Center at San Antonio). The measurements were obtained in pixels and converted to percentage. Statistically significant root resorption was found for both groups, but it was greater for the extraction group (p<0,05). The comparison of the pre and post-treatment differences of the variables between the groups demonstrated statistically significant differences for 1.NA and 1-NA (p<0,05). These differences were greater for the extraction group. Age didn't differ statistically between the groups (p>0,05). The treatment duration was found to be statistically higher for the extraction group as well as the root resorptions (p<0,05), although the later was statistically significant only for tooth #11. Statistically significant correlation was found only between root resorption and the difference between 1-NA pre and post-treatment for the extraction group (Rho=0,45; p<0,05). Based on... (Complete abstract click electronic access below) / Doutor
133

Estudo clínico comparativo dos efeitos de dois tipos de recuperadores de espaço removíveis inferiores

Costa, Carolina Covolo da January 2001 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Curso de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-18T13:14:04Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-25T21:28:50Z : No. of bitstreams: 1 179590.pdf: 3087231 bytes, checksum: c42ac3a21f05a8b157fd07a64ebc66a7 (MD5) / Com o objetivo de avaliar comparativamente os resultados obtidos pela utilização de recuperadores de espaço removíveis em 20 crianças com perdas precoces, uni ou bilaterais, de molares decíduos inferiores, 15 casos foram tratados com o sela fendida e 16, com o parafuso distalizador. Verificou-se que não houve diferença estatística quanto ao espaço recuperado pelos dispositivos, porém, como o parafuso distalizador foi usado por um menor período de tempo, a sua velocidade de recuperação de espaço foi estatisticamente superior a do sela fendida. Também evidenciou-se que ambos os dispositivos provocaram inclinação vestibular dos incisivos e, distal dos primeiros molares permanentes. A ocorrência de lesão na mucosa bucal foi evidenciada apenas em crianças com perdas bilaterais e presença de grampo circunferencial no aparelho. Foi possível concluir que o parafuso distalizador deve ser priorizado nos casos em que o fator tempo se faz relevante.
134

Comportamento mecânica da mola T de Beta-titânio: influência da marca comercial e do alivio de tensão estrutural

Caldas, Sergei Godeiro Fernandes Rabelo [UNESP] 18 January 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:23Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-01-18Bitstream added on 2014-06-13T20:05:07Z : No. of bitstreams: 1 caldas_sgfr_dr_arafo_parcial.pdf: 159727 bytes, checksum: fee225341d89c071c1bacd1faa7663e3 (MD5) Bitstreams deleted on 2015-07-02T12:36:16Z: caldas_sgfr_dr_arafo_parcial.pdf,. Added 1 bitstream(s) on 2015-07-02T12:37:35Z : No. of bitstreams: 1 000719591_20180122.pdf: 142155 bytes, checksum: 10a9c06d2e83068460f2895f04430d4b (MD5) Bitstreams deleted on 2018-01-29T11:45:00Z: 000719591_20180122.pdf,. Added 1 bitstream(s) on 2018-01-29T11:45:47Z : No. of bitstreams: 1 000719591.pdf: 779908 bytes, checksum: 46ae5fb815016e4b4b9801a1a96120f1 (MD5) / Objetivo: Os objetivos do estudo foram (1) avaliar o comportamento biomecânico das molas T confeccionadas com diferentes marcas comerciais de beta-titânio (β-Ti), (2) avaliar a estabilidade do sistema de força das molas 'T pré-ativadas por curvatura quando submetidas ao alívio de tensão estrutural a longo prazo, assim como, (3) comparar seus resultados com as molas préativadas por dobras. Materiais e Métodos: No artigo 1, a amostra foi constituída de 40 molas “T” (6 x 10mm) confeccionadas com fio 0,017” x 0.025” de β-Ti e divididas em 4 grupos de 10 molas de acordo com a marca comercial: Grupo 1 - TMA® (Ormco), Grupo 2 - BETA FLEXY® (Orthometric), Grupo 3 - BETA III TiMo® (Morelli) e Grupo 4 - CNA® (Ortho Organizers). O ensaio mecânico foi realizado utilizando-se um transdutor de momentos acoplado a um indicador para extensometria, adaptado a uma máquina de ensaios mecânicos Emic (DL2000) com célula de carga de 0,1kN e velocidade 5mm/min. Para o ensaio de tração, a amostra foi constituída de 05 segmentos com 30cm de comprimento para cada marca comercial. O ensaio foi realizado na máquina de ensaios mecânicos com célula de carga de 5kN e velocidade de 2mm/min. A análise metalográfica foi realizada por fluorescência de raios X no equipamento Energy Dispersive X-ray Fluorescence Spectrometer. A dimensão dos fios calculada com auxílio de um paquímetro digital com precisão de ± 1μm. A análise estatística foi realizada por meio da análise de variância a um critério (ANOVA) e pós teste de Tukey (α=5%). No artigo 2, a amostra foi constituída de 90 molas de dimensões 6 X 10mm, confeccionadas com fios 0,017” x 0,025” de TMA®, pré-ativadas por curvatura e divididas aleatoriamente em 9 grupos de 10 molas. As molas do grupo 1 (imediato) foram avaliadas logo após a... / Objective: The aim of this study were (1) evaluation of the force system produced by four brands of beta-titanium (β-Ti) wires bent into a T-Loop spring (TLS), (2) evaluate changes in the force system of TLSs preactivated by curvature due to stress relaxation and (3) assess the changes in the force system of TLSs preactivated by bends and curvature. Materials and Methods: The paper 1, the sample consisted of forty springs (6 x 10mm) from 0.017 x 0.025 β-Ti and divided into 4 groups of 10 springs according to wire brand: Group 1 - TMA® (Ormco), Group 2 - BETA FLEXY® (Orthometric), Group 3 - BETA III TiMo® (Morelli) and CNA® (Ortho Organizers). The mechanical testing was performed using a moment transducer coupled to a digital extensometer indicator adapted to an Emic testing machine (DL2000) with a load cell of 0.1kN and speed 5mm/min. For the tensile test, the sample consisted of five 30cm segments of each of the wires. The test was performed on a mechanical testing machine equipped with a load cell of 5kN and speed of 2mm/min. An energy dispersive X-ray fluorescence spectrometer machine was used to determine the surface chemical composition of the wires in each group. The height and width of each wire were measured to the nearest 0.001 mm with a digital micrometer accurate to ± 1μm. Statistical analysis was performed using one-way analysis of variance (ANOVA) and Tukey post hoc test (α=5%). The paper 2, the sample consisted of ninety TLSs with dimensions 6 x 10mm, produced out of .017” x .025” TMA® and preactived by gradual curvature, were randomly distributed into nine groups according to time point of evaluation. Group 1 was tested immediately and the remaining subgroups were tested after they were secured at 5 mm activation for different periods. Groups 2, 3, 4, 5, 6, 7, 8 e 9 were kept activated for 24, 48 and 72 hours... (Complete abstract click electronic access below)
135

Avaliação da efetividade de um guia radiográfico-cirúrgico mediante tomografia computadorizada

Zaragoza Velazquez, Nicolas [UNESP] 31 May 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:23Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-05-31Bitstream added on 2014-06-13T19:23:14Z : No. of bitstreams: 1 zaragozavelazquez_n_dr_araca.pdf: 683622 bytes, checksum: 4ce6029eaa78a3928cfae07ee952709a (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os mini-implantes ortodônticos têm comprovado sua eficiência clínica provendo uma ancoragem absoluta, estes dispositivos podem ser instalados sobre pequenos espaços de tecido ósseo, mas devem ser inseridos efetuando uma técnica cirúrgica muito precisa. Devido ao alto índice de contatos radiculares verificado na literatura científica pela utilização clínica dos mini-implantes, surgiu o interesse para estudar mediante tomografia computadorizada, o posicionamento tridimensional de mini-implantes ortodônticos inseridos através de um guia radiográfico-cirúrgico (RAAG). Foram considerados dois grupos neste estudo, o grupo experimental (GE) prospectivo que incluiu um total de 21 pacientes, 14 pacientes do sexo feminino e 7 do sexo masculino, com 18 anos em média. Neste grupo foram inseridos 21 parafusos ortodônticos auto-perfurantes (POAF) com diâmetro de 1.4mm e 8.0mm de comprimento por um mesmo profissional e utilizou-se um guia radiográfico-cirúrgico Ring Accupunture Auricular Guide (RAAG) com diâmetro de 3.0mm. No grupo controle (Gc) retrospectivo foram inseridos 25 (POAF) na maxila sem nenhum tipo de guia radiográfico-cirúrgico, este grupo controle (Gc) incluiu 10 pacientes do sexo feminino e 15 do sexo masculino com 18 anos em média, cada um dos POAF foi instalado por diferentes profissionais. Após a inserção dos POAF todos os 46 pacientes foram submetidos a Tomografia Dental Computadorizada mediante o Tomógrafo ICAT CONE BEAM. Para a comparação entre os grupos de estudados neste ensaio, foram utilizados os testes Kruskall Wallis e “t” de Student. O grupo experimental GE apresentou uma porcentagem de 88% de inserção eqüidistante de POAF, evidenciando significância estatística em relação ao grupo Gc. O lado direito do grupo experimental GE... / Introduction: Orthodontic Mini-Screws Self Drilling (ODMS) has proven to be effective providing an efficient absolute anchorage. It could be placed in restricted sites, but requiring a precise surgical technique. Recently (ODMS) have become more popular, thus problems has emerged for example; root contact, would lead to perforation or cause other root injuries. However, no systematic study has evaluated the tridimensional position of (ODMS) into the alveolar process, thus in order to diminish iatrogenic root damage a rapid insertion radiographic surgical guide (RAAG) was proposed to place (ODMS) precisely in the interradicular bone. A specific tomography software was used to evaluated the tridimensional position of (ODMS) and its inaccuracy was estimated <null hypothesis. Methods: The sample consisted of 46 subjects (24 female, 22 male), who used (ODMS). Twenty one (ODMS) were placed by using the (RAAG) and the twenty five (ODMS) were placed without any surgical or stent guide, cohort study. The central point of the mesiodistal septum width was the selected implant site using presurgical radiograph. The distances between (ODMS) and the adjacent teeth (5- ODMS and 6- ODMS) were measured to evaluate mini-screw centralization. These distances were statistically compared by independent kruskal wallis and t tests, scored the deviation the (ODMS) final position regarding the central point initially selected. Results: CBCT images of post-surgical (ODMS) showed that the overall success rate of (ODMS) in the (EG) was 88.0% (15/21). However, in order to obtain the equidistant placement of the (ODMS) it was necessary to change the vertical angle degree of the (15/21) (ODMS). On other hand, the... (Complete abstract click electronic access below)
136

Avaliação histológica da movimentação ortodôntica em ratos diabéticos ou osteopênicos sob ação da fotobiomodulação a laser

Maia, Luiz Guilherme Martins [UNESP] 19 March 2013 (has links) (PDF)
Made available in DSpace on 2018-07-27T18:26:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-03-19. Added 1 bitstream(s) on 2018-07-27T18:30:02Z : No. of bitstreams: 1 000737718.pdf: 3720424 bytes, checksum: d9d5c9ab7af671a168b7d7e8ca19120d (MD5) / O objetivo deste estudo foi avaliar o efeito da terapia com laser de baixa intensidade (LBI) sobre as alterações histológicas do ligamento periodontal, osso alveolar e complexo dentinapolpa de dentes submetidos à movimentação ortodôntica em ratos diabéticos e osteopênicos. Para tanto, induzimos o diabetes e osteopenia em ratos Wistar, por meio da administração de aloxana e por ovariectomia, respectivamente. Animais normoglicêmicos e ratas não ovariectomizadas funcionaram como controles. Posteriormente, o primeiro molar superior direito foi submetido à tracionamento mesial. A LBI foi realizada a 780 nm. Após o sacrifício em 7, 13 e 19 dias, os tecidos foram removidos, processados e analisados histologicamente. Em animais osteopênicos e diabéticos, a LBI reduziu significativamente a intensidade da resposta inflamatória, modulou a diferenciação osteoclástica/osteoblástica e aumentou a vascularização do ligamento periodontal, além de aumentar a organização arquitetural das fibras periodontais. Adicionalmente, a LBI também atenuou a inflamação e incrementou a vascularização em polpas dentais de dentes tracionados em ratos diabéticos, embora tenhamos observado um aumento importante na colagenização pulpar. Concluímos que ambos os distúrbios metabólicos promoveram alterações morfológicas importantes nos tecidos pulpar e periodontais durante a movimentação ortodôntica e que o laser de baixa intensidade é capaz de reverter parcial, mas não totalmente, as modificações histológicas periodontais e do complexo dentina-polpa. / The purpose of the current study was to assess the effect of the low level laser therapy (LLLT) on the histological changes of the periodontal ligament, alveolar bone, and dentinpulp complex of teeth subjected to orthodontic movement in diabetic and osteopenic rats. Therefore, we induced diabetes and osteopenia in Wistar rats, by the administration of aloxan and by ovariectomy, respectively. Normoglycemic and non-ovariectomized animals were regarded as controls. Subsequently, the upper right first molar was submitted to mesial traction. The LLLT was carried out at 780 nm. After the sacrifice of the rats in 7, 13 and 19 days, the tissues were removed, processed and analyzed in light microscope. In both osteopenic and diabetic animals, the LLLT significantly reduced the intensity of the inflammatory response, modulated the osteoblastic/osteoclastic differentiation, and increased the blood vessels content of the periodontal ligament, as well as provided better architectural arrangement of the periodontal collagen fibers. In addition, the LLLT also attenuated the inflammation and improved vascularization in dental pulps of pulled teeth of diabetic rats, although we also observed a significant increment in the pulp collagenization. We concluded that both metabolic disturbances promoted morphological changes in the pulp and periodontal tissues during dental movement, as well as that LLLT is able to partially, but not completely, reverse the histopathological findings seen in the periodontal tissues and pulp-dentin complex.
137

Análise das angulações mésio-distais de bráquetes pré-ajustados /

Verri, Ana Caroline Gonçales. January 2012 (has links)
Orientador: Marcos Rogério de Mendonça / Banca: Osmar Aparecido Cuoghi / Banca: Arnaldo Pinzan / Resumo: Objetivo: O objetivo do presente estudo foi comparar as angulações dos bráquetes metálicos pré-ajustados da prescrição Roth de incisivos centrais e caninos superiores esquerdos. Materiais e Método: Para o estudo foram selecionados 10 bráquetes, de três marcas disponíveis no mercado: GAC, Forestadent e Morelli. Foram confeccionadas duas matrizes para permitir o posicionamento padronizado dos dentes e bráquetes. A captura das imagens foi realizada a partir de fotografia orto-radial padronizada, por meio de máquina fotográfica digital, exportadas e mensuradas com o programa Image J. Resultados: Os resultados foram submetidos à análise estatística por meio da Análise de Variância (ANOVA), seguido pelo teste Tukey ao nível de significância de 5%. Os bráquetes dos incisivos centrais superiores esquerdos mostraram diferenças estatisticamente significantes entre os seguintes grupos: MOR1 em relação ao GAC1; e FOR1 em relação ao GAC1. Nos caninos superiores esquerdos as diferenças estatisticamente significantes foram entre os grupos: MOR3 em relação ao GAC3; e MOR3 em relação ao FOR3. Conclusão: Com base nos resultados pode-se concluir que, a despeito da mesma denominação para a prescrição, entre marcas diferentes, as angulações não são iguais / Abstract: Objective: The aim of this study was to compare the slot angulations of the pre-adjusted Roth prescription metallic brackets of left central maxillary incisors and left maxillary canines. Materials and Method: Ten brackets of three commercial brands were selected for this study: GAC, Forestadent and Morelli. Two individual metal matrix for brackets and tooth positioning were made for each teeth group. The captured images were made from standardized photography ortho-radial through digital camera, exported and measured with the software Image J. Results: One-way ANOVA and Tukey statistical analysis at 5% of significance level were performed. The results showed statistically significant differences between the brackets of the left maxillary central incisors between MOR1 and GAC1 groups, and between FOR1 and GAC1 groups. The data of left maxillary canines were statistically significant between MOR3 and GAC3 groups, and between MOR3 and FOR3. Conclusion: At basis of these results, it was possible conclude that despite the same prescription name of different brands, the angulations are different / Mestre
138

Análise das angulações mésio-distais de bráquetes pré-ajustados

Verri, Ana Caroline Gonçales [UNESP] 09 February 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-02-09Bitstream added on 2014-06-13T18:32:09Z : No. of bitstreams: 1 verri_acg_me_araca.pdf: 260280 bytes, checksum: f287c562e46cbb8512f0d04de04dec90 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Objetivo: O objetivo do presente estudo foi comparar as angulações dos bráquetes metálicos pré-ajustados da prescrição Roth de incisivos centrais e caninos superiores esquerdos. Materiais e Método: Para o estudo foram selecionados 10 bráquetes, de três marcas disponíveis no mercado: GAC, Forestadent e Morelli. Foram confeccionadas duas matrizes para permitir o posicionamento padronizado dos dentes e bráquetes. A captura das imagens foi realizada a partir de fotografia orto-radial padronizada, por meio de máquina fotográfica digital, exportadas e mensuradas com o programa Image J. Resultados: Os resultados foram submetidos à análise estatística por meio da Análise de Variância (ANOVA), seguido pelo teste Tukey ao nível de significância de 5%. Os bráquetes dos incisivos centrais superiores esquerdos mostraram diferenças estatisticamente significantes entre os seguintes grupos: MOR1 em relação ao GAC1; e FOR1 em relação ao GAC1. Nos caninos superiores esquerdos as diferenças estatisticamente significantes foram entre os grupos: MOR3 em relação ao GAC3; e MOR3 em relação ao FOR3. Conclusão: Com base nos resultados pode-se concluir que, a despeito da mesma denominação para a prescrição, entre marcas diferentes, as angulações não são iguais / Objective: The aim of this study was to compare the slot angulations of the pre-adjusted Roth prescription metallic brackets of left central maxillary incisors and left maxillary canines. Materials and Method: Ten brackets of three commercial brands were selected for this study: GAC, Forestadent and Morelli. Two individual metal matrix for brackets and tooth positioning were made for each teeth group. The captured images were made from standardized photography ortho-radial through digital camera, exported and measured with the software Image J. Results: One-way ANOVA and Tukey statistical analysis at 5% of significance level were performed. The results showed statistically significant differences between the brackets of the left maxillary central incisors between MOR1 and GAC1 groups, and between FOR1 and GAC1 groups. The data of left maxillary canines were statistically significant between MOR3 and GAC3 groups, and between MOR3 and FOR3. Conclusion: At basis of these results, it was possible conclude that despite the same prescription name of different brands, the angulations are different
139

Comparação da resistência ao cisalhamento de bráquetes com e sem tratamento na base utilizando três sistemas de colagem

Lugato, Isabel Cristina Prado Torres [UNESP] 13 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-13Bitstream added on 2014-06-13T18:32:11Z : No. of bitstreams: 1 lugato_icpt_me_araca.pdf: 1008270 bytes, checksum: 7cc1d52035ea072ea1322a76285600d5 (MD5) / Universidade Estadual Paulista (UNESP) / Estabilidade da colagem dos acessórios ortodônticos durante o tratamento pode ser influenciado por vários fatores, dentre eles, o sistema de colagem eleito e o0 tipo de bráquete. Frente à importância de se elucidar ao máximo possível a respeito destas variáveis, esta pesquisa foi encetada com o propósito de comparar in vitro a resistência ao cisalhamento de bráquetes metálicos ortodônticos (AbZIL-LANCER) com bases em malha convencional e bráquetes com bases em malha pré-tratadas industrialmente com jateamento de óxido de alumínio. Para a realização deste trabalho, duzentos e quarenta incisivos bovinos foram selecionados e divididos aleatoriamente em seis grupos de quarenta cada (n = 40), segundo o tipo de base do bráquete e o material de colagem utilizado. Os acessórios (AbZIL.LANCER) foram diretamente colados nos dentes bovinos com três sistemas adesivos: Sistema A - resina fotopolimerizante Transbond XT convencional (3M - Unitek, St Paul, Mn, U.S.A.); Sistema B - TransbondTM Plus Self Etching Primer (SEP) + Transbond XT (3M - Unitek, St Paul, Mn,U.S.A.) e Sistema C - cimento de ionômero de vidro resinoso Fuji ORTHO LC em cápsulas (GC Corp., Tokyo, Japan). Os testes de cisalhamento foram realizados 24 horas após a colagem dos bráquetes, utilizando uma máquina universal de ensaios DL-3000 (EMIC - Equipamentos e Sistemas de Ensaio Ltda.), utilizando célula de carga de 200 Kgf e velocidade de 1mm/min. Os resultados obtidos foram submetidos aos testes estatísticos ANOVA a dois critérios e TUKEY, ambos em nível de significância a 5%. A análise estatística demonstrou não haver diferenças estatisticamente significante entre os resultados dos testes de cisalhamento das bases comparadas. Contudo, os valores encontrados revelaram diferenças espressivas no desenpenho dos sistemas de colagem, tendo o Sistema A - (14,92MPa) apresentado os resultados mais satisfatórios... / Despite of the high-quality materials for orthodontic bonding have, an ideal bonding system has not been developed yet. The aim of this study was to test shear bond strength of two types of brackets bases. Two hundred and forty bovine incisors were randomly divided into 6 groups, according to the type of foil mesh (sandblasted or not) and the bonding materials. Brackets (AbZIL.LANCER) were directly bonded to teeth with 3 different bonding systems: System A - light-cured resin TransbondTM XT conventional XT (3M-Unitek, St Paul, Mn, U.S.A.); System B -TransbondTM XT + TransbondTM Plus Self Etching Primer (3M-Unitek, St Paul, Mn, U.S.A.) and System C - reinforced glass ionomer orthodontic cement Fuji ORTHO LC in capsules (GC Corp., Tokyo, Japan). The tests were performed 24 hours after bonding procedure in a DL 3000 (EMIC) testing machine, with a load cell of 200 Kgf in a 1mm/min speed. Results were analyzed by ANOVA and TUKEY tests at 5% of significance level. There were no statistical differences between the two types of brackets. However, there were statistical differences related to the bonding materials. Tukey's test revealed that System A presented the best shear bond strength (14,92MPa), followed by Systems B (10,66MPa) and C (13,24MPa), but there were not significantly differences between Systems A... (Complete abstract, click electronic address below)
140

Efeitos citotóxicos e genotóxicos das ligas de solda de prata em ortodontia: revisão sistemática

Garcia, Renato Dalla Porta January 2015 (has links)
Made available in DSpace on 2015-09-05T02:05:05Z (GMT). No. of bitstreams: 1 000474609-Texto+Completo-0.pdf: 859580 bytes, checksum: cb3a065e3f91d18ed57ee2c9c80a2a6f (MD5) Previous issue date: 2015 / A systematic review was performed on the cytotoxic and genotoxic effects of silver solder alloys in orthodontics. The search was conducted through medical databases, PubMed, EMBASE, Web of Science and Cochrane Library. The search of gray literature included the annals of the meetings of the Brazilian Society for Dental Research (SBPqO) and of the American Association of Orthodontists (AAO). The articles found were submitted to selection criteria and eligibility by two independent blind researchers. Afterwards, a manual search was conducted on articles’s references and study data were extracted by standardized forms. Sixty-four out of 76 articles were excluded because they did not reach the eligibility criteria. The remaining 12 articles and 3 other raised from manual search were included in this study. Two articles found on gray literature were repeated, though excluded. The level of agreement between researchers was adequate in the selection criteria (kappa = 0. 916) and very precise for the eligibility (kappa = 1). As a conclusion of the systematic review, the silver solder alloy may cause cytotoxic, mutagenic and genotoxic effects when applied on orthodontic treatment. / Foi realizada uma revisão sistemática dos efeitos citotóxicos e genotóxicos das ligas de solda de prata em Ortodontia. Para tanto, foi efetuada uma busca sistemática nas bases de dados PubMed, EMBASE, Web of Science e Biblioteca Cochrane. Foi pesquisado na literatura cinza os anais da Sociedade Brasileira de Pesquisa Odontológica (SBPqO) e os encontros anuais da American Association of Orthodontists (AAO). Os artigos encontrados foram submetidos a um critério de seleção e elegibilidade por dois pesquisadores de maneira cega e independente. Após a seleção dos estudos, uma busca manual foi realizada nas referências destes e foram extraídos os dados dos estudos através de fichas padronizadas. Foram encontrados no total 76 artigos. Destes, 64 foram excluídos, pois não preencheram os critérios de elegibilidade. Os 12 estudos remanescentes foram selecionados para o presente trabalho. Além disso, outros três artigos foram incluídos através da busca manual. Dois artigos encontrados na literatura cinza foram excluídos, pois eram repetidos. O nível de concordância entre os pesquisadores na seleção dos estudos foi considerado adequado (kappa=0,916) e para a elegibilidade dos estudos foi muito preciso (kappa=1). Após avaliação dos dados extraídos concluiu-se que ligas de solda de prata podem provocar efeitos citotóxicos, genotóxicos e mutagênicos.

Page generated in 0.0477 seconds