• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 174
  • 5
  • 4
  • 4
  • 3
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 185
  • 95
  • 29
  • 25
  • 23
  • 21
  • 21
  • 21
  • 20
  • 19
  • 19
  • 18
  • 17
  • 16
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Análise do amortecimento de modos interáreas com o método de imposição de polos. / Analysis damping of modes inter-area with the method of imposition of poles.

Carlos Alberto Febres Tapia 18 July 2013 (has links)
Este trabalho aborda as oscilações eletromecânicas de baixa frequência, relativas a modos interáreas, pouco amortecidos, avaliando o seu impacto no desempenho de redes elétricas multi-máquinas com o objetivo de elevar o amortecimento destes modos com equipamentos TCSC. Os locais apropriados para instalação destes equipamentos são escolhidos com a análise dos resíduos de funções de transferência e o ajuste de parâmetros, para o projeto coordenado de controladores, utiliza o método de imposição de polos. O sistema não linear de equações, obtido com a aplicação do método de imposição de polos, supondo coeficientes de amortecimento pré-estabelecidos, é resolvido utilizando-se o método de Newton Raphson. Adicionalmente, avalia-se a possibilidade do método auxiliar na análise de interações entre controladores e identificação de acoplamentos, por meio da análise dos termos que compõem as equações de imposição de polos. / This work deals with low frequency oscillations related to inter-area modes, evaluating their impact on the performance of multi-machine electrical networks with the aim to increase the damping of these modes using TCSC. The best places to install these devices are chosen with the analysis of the residues of transfer functions and the parameter fitting for coordinated application of stabilizers is performed with the pole placement method. The nonlinear system of equations, obtained with the pole placement method, assuming specified damping factors, is solved with the Newton-Raphson method. The method is also used in the analysis of control interaction among stabilizers through the evaluation of individual parcels of the pole placement equations, as an additional feature of the approach.
172

Oscilações de Rabi em redes ópticas não lineares. / Rabi oscillations in nonlinear optical lattices.

Silva, Cícero Rita da 31 March 2008 (has links)
Abstract An optical lattice is a periodic array produced by the superposition of two or more counter-propagating laser beams which interfere and create a spatial periodic intensity pattern. An important difference between a solid state crystalline lattice and an optically induced lattice is that the latter have a longer coherence time which permits the observation of coherent phenomenon such as Bloch oscillations. Recently, an interesting effect has been reported in the literature, which is the analogue of Rabi oscillations in two level systems driven by an external optical field: an optical beam composed by pair of frequencies, resonants with the high symmetry points of the Brillouin zone, propagating through an optical lattice exhibits oscillations of the Fourier ways between the frequencies due to the coupling with the lattice. Therefore, in the optical case the field plays the role of the matter, while the lattice plays the role of the driving field which couples the frequencies. Based in this result, the objective of this paper is to investigate the influence of self-defocusing in the optical Rabi oscillation. We have shown, through numerical calculation of the wave nonlinear equation, that in the self-defocusing optical lattice, these oscillations go disappearingare. The result of the disappearance of the oscillations of Fourier can be understood considering that self-defocusing promotes an addition of phases in the ways that were resonant - kB and kB, in different way, form that the basic difference between kB and - kB will not be plus a vector of the reciprocal net, and as consequence the oscillations of optic Rabi disappear, therefore the coupling with the net requires this condition in the resonant frequencies. / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Resumo Uma rede opticamente induzida é um arranjo periódico produzido pela superposição de dois ou mais feixes de laser que ao interferirem criam um padrão de intensidade periódico espacial. Uma importante diferença entre uma rede cristalina no estado sólido e uma rede produzida opticamente é que a última apresenta um tempo de coerência longo, permitindo a observação de fenômenos coerentes tal como as oscilações de Bloch. Recentemente, um efeito interessante análogo às oscilações de Rabi em um sistema atômico de dois níveis impulsionado por um campo externo, foi publicado na literatura: um feixe óptico composto de um par de freqüências, ressonantes com os pontos de alta simetria da zona de Brillouin, propagando - se através de uma rede óptica exibe oscilações dos modos de Fourier entre as freqüências adequadas para o acoplamento com a rede. Portanto, no caso óptico o campo representa a matéria, enquanto a rede representa a intensidade do campo aplicado que acopla as freqüências. Baseado neste resultado, o objetivo desta dissertação é investigar a influência da auto - desfocalização nas oscilações ópticas de Rabi. Demonstraremos, através de cálculos numéricos da equação de onda não linear, que em uma rede opticamente induzida na presença da auto - desfocalização, essas oscilações vão desaparecendo. O resultado do desaparecimento das oscilações de Fourier pode ser compreendidoconsiderando que a auto - desfocalização promove um adicionamento de fases nos modos que eram ressonantes -kB e kB, de maneira diferente, de forma que a diferença básica entre kB e -kB não será mais um vetor da rede recíproca, e como conseqüência as oscilações de Rabi óptica desaparecem, pois o acoplamento com a rede requer esta condição nas freqüências ressonantes.
173

Análise em tempo real da impedância do sistema respiratório e da mobilidade toracoabdominal em portadores de DPOC com obstrução brônquica acentuada / Real-time analysis of respiratory system impedance and thoracoabdominal mobility of COPD patients with severe bronchial obstruction

Karla Kristine Dames da Silva 19 March 2009 (has links)
Introdução: A DPOC caracteriza-se pela limitação ao fluxo aéreo associada à resposta inflamatória anormal dos pulmões a partículas ou gases nocivos. As alterações mecânicas decorrentes da DPOC estão relacionadas com a disfunção mecânica das fibras do diafragma, já observadas nas fases iniciais da doença. Alguns estudos têm demonstrado o elevado potencial da Técnica de Oscilações Forçadas (FOT) na detecção das alterações mecânicas da DPOC. Contudo, tais aplicações da FOT não permitiam a análise em tempo real das alterações do sistema respiratório, bem como da mobilidade toracoabdominal destes indivíduos. Desta forma, os objetivos desta pesquisa foram analisar, em tempo real, as alterações de impedância do sistema respiratório nas distintas fases do ciclo em portadores de DPOC, assim como avaliar a movimentação toracoabdominal destes indivíduos. Metodologia: Trata-se de um estudo observacional controlado, prospectivo onde foram analisados 48 indivíduos, 23 indivíduos controles e 25 portadores de DPOC com grau de obstrução acentuado. Os indivíduos realizaram exames de FOT para análise da impedância do sistema respiratório e mobilidade toracoabdominal, simultaneamente. Posteriormente aos exames da FOT os indivíduos foram submetidos à Espirometria. Resultados: Os resultados demonstraram aumento da impedância do sistema respiratório nos indivíduos com DPOC em comparação ao grupo controle, em nos parâmetros estudados (Zt, Zi, Ze, Zii, Zie, Zrs e Zpp) (p<0,0001). Em relação às distintas fases do ciclo, os indivíduos deste estudo apresentaram impedâncias maiores na fase inspiratória quando comparadas à fase expiratória (p<0,004). Somente 10% dos portadores de DPOC apresentaram assincronia toracoabdominal (&#966; &#8805; 45), sendo que os valores médios não apresentaram diferença estatística quando comparados ao grupo controle. Discussão: A impedância total do sistema respiratório (Zt) aumentada nos portadores de DPOC confirma o aumento da carga mecânica do sistema respiratório destes indivíduos. Essas alterações são coerentes com o processo fisiopatológico, evidenciado pela obstrução ao fluxo aéreo e destruição do parênquima pulmonar. O aumento da impedância na fase inspiratória quando comparada à fase expiratória, sugere um aumento no trabalho resistivo e elástico. Não foram evidenciados sinais de assincronia na mobilidade toracoabdominal na maior parte dos indivíduos, sugerindo que alguns mecanismos adaptativos atuam na tentativa de evitar a fadiga do músculo respiratório. Conclusões: A DPOC resulta no aumento da carga mecânica do sistema respiratório, alterações identificadas pelo aumento da impedância do sistema respiratório, medida pela FOT em tempo real. Este aumento foi mais evidente durante a fase inspiratória. A mobilidade toracoabdominal não se mostrou alterada na maior parte dos indivíduos com DPOC. Estes resultados são consistentes com publicações prévias e fundamentos fisiopatológicos, confirmando o potencial da FOT monofreqüência na avaliação das modificações relacionadas à DPOC. / Introduction: COPD is carachterized by airflow limitation associated abnormal inflammatory response of the lung to noxious particles or gases. The mechanical alterations associated with COPD have been related with dysfunction of the diaphragm, observed since the initial phases of the disease. Several studies have confirmed the high potential of FOT in the assessment of the mechanics modifications related to COPD. However, such studies did not allow a real-time analysis of the changes in the respiratory system, and the thoracoabdominal mobility of these individuals. Thus, the goals of the present study were to analyze, in real-time, the impedance alterations of the respiratory system in different phases of the respiratory cycle of COPD patients. Methodology: This research consists of a controlled observational study where 48 individuals were analyzed, 23 controls and 25 individuals with COPD and severe airway obstruction. Firstly, they performed simultaneous analysis of impedance of the respiratory system and thoracoabdominal motion. In subsequent examinations, these subjects were submitted to spirometry. Results: The results demonstrated an increase of the respiratory system impedance in individuals with COPD compared with the control group in all of the studied parameters (Zt, Zi, Ze, Zii, Zie, &#916;Zrs e Zpp) (p<0.0001). Considering the different phases of the respiratory cycle, higher impedances were observed in the inspiratory phase (p<0.004). Only 10% of individuals with COPD showed thoracoabdominal asynchrony (&#966;&#8805; 45), and the mean values showed no statistical difference when compared to the control group. Discussions: The total impedance of the respiratory system increased in individuals with COPD, which describes the increase of the mechanic load of the respiratory system in these individuals. These alterations are coherent with the physiopathology of COPD, associated with airflow obstruction and lung parenchyma destruction. The increase of the impedance in the inspiratory phase suggests an increase of the resistive and elastic work. There were not signals of thoracoabdominal asynchrony in the major part of the studied individuals, suggesting that some adaptation mechanisms act to compensate respiratory muscle fatigue. Conclusion: The COPD results in the increase of the mechanic load of the respiratory system. These alterations were identified by the increase of the respiratory system impedance, which was more evidence in the inspiratory phase. The thoracoabdominal asynchrony was not usual in individuals with COPD. Those results are consistent with previously published data and physiopathological fundamentals, confirming the potential of monofrequency FOT in the assessment of the modifications related to COPD.
174

Análise em tempo real da impedância do sistema respiratório e da mobilidade toracoabdominal em portadores de DPOC com obstrução brônquica acentuada / Real-time analysis of respiratory system impedance and thoracoabdominal mobility of COPD patients with severe bronchial obstruction

Karla Kristine Dames da Silva 19 March 2009 (has links)
Introdução: A DPOC caracteriza-se pela limitação ao fluxo aéreo associada à resposta inflamatória anormal dos pulmões a partículas ou gases nocivos. As alterações mecânicas decorrentes da DPOC estão relacionadas com a disfunção mecânica das fibras do diafragma, já observadas nas fases iniciais da doença. Alguns estudos têm demonstrado o elevado potencial da Técnica de Oscilações Forçadas (FOT) na detecção das alterações mecânicas da DPOC. Contudo, tais aplicações da FOT não permitiam a análise em tempo real das alterações do sistema respiratório, bem como da mobilidade toracoabdominal destes indivíduos. Desta forma, os objetivos desta pesquisa foram analisar, em tempo real, as alterações de impedância do sistema respiratório nas distintas fases do ciclo em portadores de DPOC, assim como avaliar a movimentação toracoabdominal destes indivíduos. Metodologia: Trata-se de um estudo observacional controlado, prospectivo onde foram analisados 48 indivíduos, 23 indivíduos controles e 25 portadores de DPOC com grau de obstrução acentuado. Os indivíduos realizaram exames de FOT para análise da impedância do sistema respiratório e mobilidade toracoabdominal, simultaneamente. Posteriormente aos exames da FOT os indivíduos foram submetidos à Espirometria. Resultados: Os resultados demonstraram aumento da impedância do sistema respiratório nos indivíduos com DPOC em comparação ao grupo controle, em nos parâmetros estudados (Zt, Zi, Ze, Zii, Zie, Zrs e Zpp) (p<0,0001). Em relação às distintas fases do ciclo, os indivíduos deste estudo apresentaram impedâncias maiores na fase inspiratória quando comparadas à fase expiratória (p<0,004). Somente 10% dos portadores de DPOC apresentaram assincronia toracoabdominal (&#966; &#8805; 45), sendo que os valores médios não apresentaram diferença estatística quando comparados ao grupo controle. Discussão: A impedância total do sistema respiratório (Zt) aumentada nos portadores de DPOC confirma o aumento da carga mecânica do sistema respiratório destes indivíduos. Essas alterações são coerentes com o processo fisiopatológico, evidenciado pela obstrução ao fluxo aéreo e destruição do parênquima pulmonar. O aumento da impedância na fase inspiratória quando comparada à fase expiratória, sugere um aumento no trabalho resistivo e elástico. Não foram evidenciados sinais de assincronia na mobilidade toracoabdominal na maior parte dos indivíduos, sugerindo que alguns mecanismos adaptativos atuam na tentativa de evitar a fadiga do músculo respiratório. Conclusões: A DPOC resulta no aumento da carga mecânica do sistema respiratório, alterações identificadas pelo aumento da impedância do sistema respiratório, medida pela FOT em tempo real. Este aumento foi mais evidente durante a fase inspiratória. A mobilidade toracoabdominal não se mostrou alterada na maior parte dos indivíduos com DPOC. Estes resultados são consistentes com publicações prévias e fundamentos fisiopatológicos, confirmando o potencial da FOT monofreqüência na avaliação das modificações relacionadas à DPOC. / Introduction: COPD is carachterized by airflow limitation associated abnormal inflammatory response of the lung to noxious particles or gases. The mechanical alterations associated with COPD have been related with dysfunction of the diaphragm, observed since the initial phases of the disease. Several studies have confirmed the high potential of FOT in the assessment of the mechanics modifications related to COPD. However, such studies did not allow a real-time analysis of the changes in the respiratory system, and the thoracoabdominal mobility of these individuals. Thus, the goals of the present study were to analyze, in real-time, the impedance alterations of the respiratory system in different phases of the respiratory cycle of COPD patients. Methodology: This research consists of a controlled observational study where 48 individuals were analyzed, 23 controls and 25 individuals with COPD and severe airway obstruction. Firstly, they performed simultaneous analysis of impedance of the respiratory system and thoracoabdominal motion. In subsequent examinations, these subjects were submitted to spirometry. Results: The results demonstrated an increase of the respiratory system impedance in individuals with COPD compared with the control group in all of the studied parameters (Zt, Zi, Ze, Zii, Zie, &#916;Zrs e Zpp) (p<0.0001). Considering the different phases of the respiratory cycle, higher impedances were observed in the inspiratory phase (p<0.004). Only 10% of individuals with COPD showed thoracoabdominal asynchrony (&#966;&#8805; 45), and the mean values showed no statistical difference when compared to the control group. Discussions: The total impedance of the respiratory system increased in individuals with COPD, which describes the increase of the mechanic load of the respiratory system in these individuals. These alterations are coherent with the physiopathology of COPD, associated with airflow obstruction and lung parenchyma destruction. The increase of the impedance in the inspiratory phase suggests an increase of the resistive and elastic work. There were not signals of thoracoabdominal asynchrony in the major part of the studied individuals, suggesting that some adaptation mechanisms act to compensate respiratory muscle fatigue. Conclusion: The COPD results in the increase of the mechanic load of the respiratory system. These alterations were identified by the increase of the respiratory system impedance, which was more evidence in the inspiratory phase. The thoracoabdominal asynchrony was not usual in individuals with COPD. Those results are consistent with previously published data and physiopathological fundamentals, confirming the potential of monofrequency FOT in the assessment of the modifications related to COPD.
175

Retificador híbrido trifásico com fator de potência unitário, alta densidade de potência e ampla faixa de regulação de tensão no barramento em corrente contínua para conexão em microrredes

Rodrigues, Danillo Borges 25 August 2016 (has links)
Este trabalho apresenta a análise e o desenvolvimento experimental de uma estrutura topológica de retificador híbrido trifásico que oferece as características operacionais de imposição de correntes de linha de entrada senoidais, de alto fator de potência, de reduzida distorção harmônica total de corrente e de fornecimento de um barramento CC com tensão regulada utilizando a inovadora técnica de Compensação Série de Tensão no Barramento CC tanto para condições normais de suprimento da rede elétrica como para condições de afundamentos temporários de tensão equilibrados e desequilibrados na rede CA. Para corroborar com a teoria exposta e com as análises de simulação computacional, um protótipo de 5 kW foi construído e ensaios experimentais realizados em laboratório permitiram demonstrar que para condições normais de suprimento da rede CA a solução proposta assegura distorções harmônicas de corrente na ordem de 2% e um fator de potência por fase próximo do valor unitário (0,996), além de ser capaz de regular e manter a tensão no barramento CC constante mesmo durante o transitório provocado por um degrau de carga de alta potência. Durante a ocorrência de afundamentos de tensão, a estrutura é capaz de regular a tensão do barramento CC no valor de referência estabelecido, assegurando elevado fator de potência mesmo durantes estes distúrbios da rede CA de alimentação. Destaca-se que estas características operacionais, além de serem alcançadas com os conversores chaveados que compõem a estrutura processando apenas uma parcela da potência total de saída, tornando o conjunto mais eficiente e robusto, fazem da estrutura proposta uma excelente alternativa para aplicações com elevados níveis de potência envolvendo a alimentação de cargas CC sensíveis aos distúrbios provocados pela rede CA e para aplicações que compreendem a compensação de oscilações de tensão devido às intermitências dos sistemas de microgeração que compõem as redes de distribuição em corrente contínua das microrredes. / This work presents the analysis and the experimental development of a topological structure of three-phase hybrid rectifier, which provides operational characteristics for imposing sinusoidal input line currents, with high power factor, low current total harmonic distortion and providing a DC bus with regulated voltage using the innovative technique of Series Voltage Compensation in the DC Bus for both normal conditions of mains power supply and for temporary sags for balanced and unbalanced voltage ac power supply conditions. In order to corroborate the exposed theory and with computational simulation analysis, a 5 kW prototype was assembled and experimental tests were conducted in laboratory. The results demonstrated that under normal conditions of AC mains supply the proposed solution ensures harmonic distortions about 2 % for the input AC currents and a power factor per phase approximately unitary (0.996). Moreover, the prototype can regulate and maintain the DC bus voltage in a constant value even during the transient caused by a high-power load step. During the occurrence of voltage sags, the structure can regulate the DC bus voltage in the established reference value, ensuring high power factor even during AC mains power supply disturbances. One can emphasize that these operational characteristics, in addition of being achieved with the switched converters that comprise the structure processing only an amount of the total output power, was observed that the whole assembly is more efficient and robust. The proposed structure is an excellent alternative for supplying high power DC loads sensitive to disturbances caused by AC mains and for applications involving voltage oscillations compensation due to intermittences of microgeneration systems that are connected to DC distribution of microgrids. / Tese (Doutorado)
176

Efeitos da operação do gerador de indução no comportamento do gerador síncrono operando em um sistema isolado alimentando cargas não lineares / Effects of the induction generator operation on the synchronous generator behavior operating on an isolated system feeding nonlinear loads

Oliveira, José Mário Menescal de 13 July 2018 (has links)
Submitted by Liliane Ferreira (ljuvencia30@gmail.com) on 2018-09-14T11:19:37Z No. of bitstreams: 2 Tese - José Mário Menescal de Oliveira - 2018.pdf: 3555364 bytes, checksum: 7da381c5690449c518f20f2a3fd49fea (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2018-09-17T10:48:33Z (GMT) No. of bitstreams: 2 Tese - José Mário Menescal de Oliveira - 2018.pdf: 3555364 bytes, checksum: 7da381c5690449c518f20f2a3fd49fea (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-09-17T10:48:33Z (GMT). No. of bitstreams: 2 Tese - José Mário Menescal de Oliveira - 2018.pdf: 3555364 bytes, checksum: 7da381c5690449c518f20f2a3fd49fea (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-07-13 / This thesis demonstrates the effects of harmonic pollution in a salient pole synchronous generator and an induction generator operating in parallel on an isolated system, supplying a non-linear load. The main contributions of this research-study consist of identifying and quantifying the oscillations that non-linear load cause on the electric variables of synchronous and induction generators, such as, the electromagnetic conjugate that presents oscillations of sixth harmonic due to the distorted currents. / Este trabalho mostra os efeitos da poluição harmônica em um gerador síncrono de polos salientes e um gerador de indução operando em paralelo em um sistema isolado suprindo carga não linear. As principais contribuições deste trabalho consistem em identificar e quantificar as oscilações que a carga não linear utilizada provoca nas variáveis elétricas dos geradores síncronos e dos geradores de indução, tal como, o conjugado eletromagnético que apresenta oscilações de sexto harmônico devido as correntes distorcidas.
177

Procedimento de projeto de controladores robustos para o amortecimento de oscilações eletromecânicas em sistemas de potência. / Robust controller design procedure for electromechanical oscillation damping in power systems.

Rodrigo Andrade Ramos 16 December 2002 (has links)
Este trabalho propõe uma nova metodologia de projeto de controladores para o amortecimento de oscilações eletromecânicas de baixa freqüência em sistemas de potência. Considerando a necessidade de se aumentar a robustez dos estabilizadores clássicos frente a variações nas condições de operação, este estudo analisou uma série de requisitos práticos a serem atendidos pelos novos controladores de amortecimento e desenvolveu a metodologia proposta, de tal forma que os controladores projetados pudessem satisfazer a todos os requisitos analisados. Foram tratadas questões relativas à estrutura de controle (realimentação dinâmica descentralizada de saída), à robustez de estabilidade e desempenho (através da modelagem politópica e dos critérios de posicionamento regional de pólos) e da não atuação dos controladores em regime permanente (com a inclusão de filtros washout na modelagem). A principal vantagem desta metodologia proposta é a possibilidade de se garantir formalmente um desempenho robusto dos controladores, dentro de uma região pré-especificada de pontos de operação. Os resultados, obtidos através de simulações não lineares da resposta (para uma série de perturbações) dos sistemas escolhidos para teste, em diversas condições de operação, mostram que os controladores obtidos com a aplicação desta metodologia são capazes de manter seu desempenho frente às variações consideradas. Além disso, a obtenção de resultados satisfatórios com a aplicação desta metodologia a um sistema com 45 variáveis de estado indica boas perspectivas para a utilização conjunta da mesma com técnicas de redução do modelo de estados, para o projeto de controladores de amortecimento em sistemas reais de grande porte. / This research proposes a new methodology for the design of controllers to damp low frequency electromechanical oscillations in power systems. Considering the need to improve the robustness of the classical stabilizers, with respect to variations in the operating conditions, this study has analyzed a series of practical requirements to be met by the new damping controllers and developed the proposed methodology, so the designed controllers could satisfy all the analyzed equirements. Questions regarding the controller structure (decentralized dynamic output feedback), the robustness of stability and performance (through the polytopic modelling and the regional pole placement criteria) and the non influence of the controllers over the steady state behavior of the system (with the inclusion of washout filters in the model) were treated. The main advantage of the proposed methodology is the possibility to ensure, formally, the performance robustness of the controllers, within a previously specified region of operating points. The results, obtained through the eigenanalysis of the closed loop system and the nonlinear simulations of the system responses to a series of disturbances, in various operating conditions, show that the controllers provided by this new methodology are capable of maintaining their performance, despite the considered variations. Moreover, the satisfactory results obtained with the application of this methodology to a system with 45 state variables indicates good perspectives for the joint utilization of the methodology and model order reduction techniques, for the design of damping controllers for real-sized systems.
178

Oscilações coletivas e avalanches em redes de neurônios estocásticos

DORNELLES, Leonardo Dalla Porta 26 August 2016 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2017-03-09T12:11:00Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertacao_LeonardoDallaPorta.pdf: 4244662 bytes, checksum: 214ab17f2ee3583441af553e0a0a7931 (MD5) / Made available in DSpace on 2017-03-09T12:11:00Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertacao_LeonardoDallaPorta.pdf: 4244662 bytes, checksum: 214ab17f2ee3583441af553e0a0a7931 (MD5) Previous issue date: 2016-08-26 / FACEPE / Avalanches neuronais, assim como oscilações e sincronização, são padrõesde atividade espontânea observados em redes neuronais. O conceito de avalanches neuronais foi concebido na última década.EssepadrãodeatividadetemdistribuiçõesdetamanhosP(s)eduraçõesP(d)invariantes por escala, i.e., obedecem relações do tipo lei de potênciaP(s)∼s−τ, com expoenteτ≃3/2, e P(d)∼d−τt, com expoenteτt ≃2, respectivamente. Essas propriedades são compatíveis com a ideia de que o cérebro opera em um regime crítico. A partir dessas constatações, muitos estudos teóricos e experimentais reportaram os potenciais benefícios de um cérebro operando na criticalidade, como por exemplo a máxima sensibilidade aos estímulos sensoriais, máxima capacidade de informação e transmissão e uma ótima capacidade computacional. Modelos da classe de universalidade de percolação direcionada (DP) têm sido amplamente utilizados para explicar a estatística invariante por escala das avalanches neuronais. Porém estes modelos não levam em consideração a dinâmica dos neurônios inibitórios e, além disso, como apresentam uma transição de fase entre um estado absorvente e uma fase ativa, torna-se difícil conciliar o modelo com correlações temporais de longo alcance que são observadas experimentalmente em diferentes escalas espaciais. Neste contexto, um novo modelo computacional (CROs, do original em inglês Critical Oscillations) surgiu na literatura (Poil et al., J. Neurosci.,32 9817, 2012), incluindo neurônios inibitórios e buscando conciliar correlações temporais com avalanches neuronais. Neste modelo não há uma fase absorvente, e uma suposta transição de fases ocorre entre uma fase ativa e outra com oscilações coletivas. Devido à ausência de uma fase absorvente, avalanchesneuronaissãodefinidascomparando-seaatividadeinstantâneadaredecomumlimiar que depende da mediana da atividade total. Justamente na linha crítica do espaço de parâmetros, quandoháumabalançoentreexcitaçãoeinibiçãoneuronal,avalanchesneuronaisinvariantespor escala são observadas juntamente com correlações temporais de longo alcance (ruído 1/f). No presente trabalho, um estudo mais profundo a respeito dos resultados reportados para o modelo CROs foi realizado. As oscilações neuronais mostraram-se robustas para diferentes tamanhos de rede, e observamos que a dinâmica local reflete a dinâmica oscilatória global da rede. Correlações temporais de longo alcance foram observadas (num intervalo de escalas temporais) através da técnica deDetrendedFluctuationAnalysis, sendo robustas perante modificações no tamanho da rede. O resultado foi confirmado pela análise direta do espectro, que apresentou decaimento do tipo 1/f numa determinada faixa de frequências. O diagrama de fases do modelo mostrou-se robusto em relação ao tamanho da rede, mantendo-se o alcance das interações locais. Entretanto,osresultadosmostraram-sefortementedependentesdolimiarutilizadoparadetecção dasavalanchesneuronais.Porfim,mostramosquedistribuiçõesdeduraçõesdeavalanchessãodo tipo lei de potência, com expoenteτt ≃2. Este resultado é inédito e o valor encontrado coincide com o expoente crítico da classe de universalidade de DP na dimensão crítica superior. Em conjunto, nossos resultados fornecem mais evidências de que o modelo CROs de fato apresenta uma transição de fases. / Neuronal avalanches, as well as waves and synchronization, are types of spontaneous activity experimentally observed in neuronal networks. The concept of neuronal avalanches was conceivedinthepastdecade.ThispatternofactivityhasdistributionsofsizeP(s)anddurationP(d) which are scale invariant, i.e., follow power-law relationsP(s)∼s−τ, with exponentτ≃3/2, and P(d)∼ d−τd, with exponentτt ≃ 2, respectively. These properties are compatible with the idea that the brain operates in a critical regime. From these findings, many theoretical and experimental studies have reported the potential benefits of a brain operating at criticality, such as maximum sensitivity to sensory stimuli, maximum information capacity and transmission and an optimal computational capabilities. Models belonging to the directed percolation universality class (DP) have been widely used to explain the scale invariant statistic of neuronal avalanches. However,these modelsdo not take into account the dynamics ofinhibitory neuronsand, since as they present a phase transition between an absorbing state and an active phase, it is difficult to reconcile the model with long-range temporal correlations that are observed experimentally at different spatial scales. In this context, a new computational model (CROs, Critical Oscillations) appeared in the literature (Poil et al., J. Neurosci.,32 9817, 2012), including inhibitory neurons and seeking to reconcile temporal correlations with neuronal avalanches. In this model there is no absorbing phase, and a supposed phase transition occurs between an active phase and another with collective oscillations. Due to the lack of an absorbing phase, neuronal avalanches are defined comparing by the instant network activity with a threshold that depends of the total activity median. Precisely at the critical line in parameter space, when a balance between neuronal excitation and inhibition occurs, scale invariant neuronal avalanches are observed with long-range temporal correlations (1/f-like noise). In the present work, a deeper study about the resultsreportedfortheCROsmodelwasperformed.Neuronaloscillationshavebeenshowntobe robust to increasing network sizes, and it was observed that local dynamic reflects the oscillatory global dynamic of the network. Long-range temporal correlations were observed (in a range of time scales) via Detrended Fluctuation Analysis, being robust against changes in network size. The result was confirmed by direct analysis of the spectrum, which showed a decay like 1/f in a given frequency band. The phase diagram of the model was robust with respect to the network size, as long as the range of local interactions was kept. However, the results were dependent of the thresholdused to detect neuronal avalanches.Finally,we have shown thatthe distributions of avalanches duration follows a power-law with exponentτt ≃2. This result is unprecedented and the value obtainedcoincides with the criticalexponent of the DP universality class in the upper criticaldimension.Together,ourresultsprovidefurtherevidencethatinfacttheCROsmodel presents aphasetransition.
179

Interações não padrão de neutrinos no modelo 331 com setor de Higgs mínimo / Non-standard interactions of neutrinos in the 331 model with minimal Higgs sector

Medina Jaime, Miguel, 1983- 16 August 2018 (has links)
Orientador: Pedro Cunha de Holanda / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Física Gleb Wataghin / Made available in DSpace on 2018-08-16T08:47:51Z (GMT). No. of bitstreams: 1 MedinaJaime_Miguel_M.pdf: 2665434 bytes, checksum: ff126a38e30aec81b803a8fdcddcbc96 (MD5) Previous issue date: 2010 / Resumo: Neste trabalho apresentamos um estudo de alguns problemas que ainda não forem esclarecidos na física de neutrinos do modelo padrão (MP) e encaminhamos eles na direção de física nova. Para esse fim, estuda-se uma classe de extensões de Gauge quirais do MP com simetria SU(3)C x SU(3)L x U(1)X (modelos 331), onde estudamos a interação eletrofraca dos neutrinos com a matéria via correntes carregadas e neutras (CC e CN) através dos bósons Gauge do modelo para processos de espalhamento elástico coerente. Finalmente, encontramos vínculos entre as contribuições não padrão no modelo 331 com as interações não padrão (INP) em experimentos de seção de choque, onde encontramos que o modelo 331 apresenta INP diagonais universais da ordem e a M2 W,Z / M2 X <~ O(10-3). Mostramos que o valor esperado no vácuo (VEV) para o tão procurado bóson de Higgs neste modelo tem que ser ?2 <~174.105GeV e os VEV V > 1.3TeV e 142 GeV < ?1 < 201GeV. Os novos bósons do modelo deverão ter massas maiores a 610 GeV / Abstract: We present a study of some problems that are not yet clarified in Standard Model (SM) neutrino physics and guide them in the direction of new physics. To this aim, we study a class of extensions of the SM Gauge chiral symmetry SU(3)CSU(3)LU(1)X (331 model), where we study the electroweak interaction of neutrinos with matter via charged and neutral current (CC and NC) by the gauge bosons of the model for coherent elastic scattering process. We finally found connections between the non-standard contributions on 331 with non-standard interactions (NSI) in cross section experiments, where we find that the model 331 has diagonal universal NSI of order e a M2 W,Z / M2 X <~ O(10-3) . We show that the expected value in vacuum (VEV) for the quite searched Higgs boson in this model has to be ?2 <~174.105 GeV and the VEV V > 1.3TeV and 142 GeV < ?1 < 201 GeV. The new bosons of the model must have masses greater than 610 GeV / Mestrado / Física das Particulas Elementares e Campos / Mestre em Física
180

Estimação de fasores na presença de harmônicos, decaimentos CC exponencial e inter-harmônicos exponencialmente amortecidos

Vianello, Rodrigo 24 February 2010 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-12-22T11:06:45Z No. of bitstreams: 1 rodrigovianello.pdf: 847018 bytes, checksum: 7ad17011832e8156b0fa361091a1375a (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-12-22T12:53:13Z (GMT) No. of bitstreams: 1 rodrigovianello.pdf: 847018 bytes, checksum: 7ad17011832e8156b0fa361091a1375a (MD5) / Made available in DSpace on 2016-12-22T12:53:13Z (GMT). No. of bitstreams: 1 rodrigovianello.pdf: 847018 bytes, checksum: 7ad17011832e8156b0fa361091a1375a (MD5) Previous issue date: 2010-02-24 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O presente trabalho apresenta a proposição de duas metodologias inovadoras no campo da estimação fasorial. A primeira delas propõe a estimação do fasor da componente fundamental na presença de harmônicos e decaimento CC exponencial e é baseada na aplicação de filtros DFT (Discrete Fourier Transform) e de alguns métodos de processamento de sinais, tais como janelamento, modulação e DTFT (Discrete Time Fourier Transform). A segunda metodologia também propõe a estimação do fasor da componente fundamental, mas em um cenário mais complexo onde estão presentes no sinal, além dos harmônicos e decaimento CC exponencial, as oscilações subsíncronas. Esta metodologia é baseada na aplicação de redes neurais artificiais e de alguns métodos de processamento de sinais. Ambas as metodologias foram avaliadas frente a métodos tradicionais de estimação fasorial e apresentaram desempenhos superiores na presença de ruídos. / Thisthesispresents thepropositionoftwonovelmethodsin thefieldofphasor estimation. The first proposes to estimate the phasor of the fundamental component in the presence of harmonicsandexponentialdecayingDC.ThismethodologyisbasedontheapplicationoffiltersDFT (Discrete Fourier Transform) and some methods of signal processing such as windowing, modulation and DTFT (Discrete Time Fourier Transform). The second approach also proposes to estimate the phasor of the fundamental component, but in a more complex scenario formed for harmonics, exponential decaying DC and the sub-synchronous oscillations . This methodology isbasedontheapplicationofartificialneuralnetworksandsomemethodsofsignalprocessing. Both methods were evaluated against traditional methods of phasor estimation and the simulations showed that the two proposed methods were more accurate then others in presence of noise.

Page generated in 0.0296 seconds