• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 60
  • 50
  • 4
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 172
  • 172
  • 89
  • 48
  • 45
  • 41
  • 41
  • 37
  • 36
  • 34
  • 33
  • 33
  • 33
  • 31
  • 28
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Otoacoustic Emissions: The Influence of the Middle-ear Function, SFOAEs, and OAEs as a Diagnostic Predictor for Cochlear Impairment

Smurzynski, Jacek 02 March 2012 (has links)
No description available.
122

Extended High-frequency Audiometry and DPOAEs in Patients with Unilateral Tinnitus

Smurzynski, Jacek, Fabijanska, Anna, Kochanek, Krzysztof 01 January 2010 (has links)
No description available.
123

Wideband Transient Otoacoustic Emissions in Ears with Normal Hearing and Sensorineural Hearing Loss

Schairer, Kim, Keefe, Douglas H., Fitzpatrick, Denis, Putterman, Daniel, Kolberg, Elizabeth, Garinis, Angie, Kurth, Michael, McGregor, Kara, Light, Ashley, Feeney, M. P. 18 October 2018 (has links)
Otoacoustic emissions (OAEs) are generated in the cochlea in response to sound and are used clinically to separate ears with normal hearing from sensorineural hearing loss (SNHL). OAEs were elicited at ambient pressure by clicks (CEOAE) and wideband chirps (TEOAE) sweeping from low-to-high frequency with a sweep rate of either 187.6 Hz/ms (short chirps) or 58.2 Hz/ms (long chirps) and a bandwidth extending to 8 kHz. Chirps were presented at the same sound exposure level (SEL) as clicks, or + 6 dB relative to clicks. A total of 288 OAE waveforms were averaged for short chirps in ~1 minute compared to 120 waveforms for long chirps. Compared to clicks, the chirp has a lower crest factor, which allows it to be presented at an overall higher SEL without distortion. OAEs were elicited in 79 adults with normal hearing and 51 adults with mild-to-moderate SNHL. One-sixth octave OAE signal-to-noise ratios from 0.7 to 8.0 kHz were compared across stimulus types and conditions. The area under the receiver operating curve (AUC) was used to assess the accuracy of detecting SNHL. Average AUCs across 1/6th octave frequencies ranged from 0.90 to 0.89 for TEOAEs and were 0.87 for the CEOAE suggesting excellent test performance.
124

Effects of Supplemental Magnesium on Temporary Threshold Shift: Distortion Product Otoacoustic Emissions

Leonard, Jenifer 01 July 2003 (has links)
Previous studies have shown that supplemental magnesium administered prior to exposure to noise has an alleviating effect on temporary threshold shift (TTS). These studies have only used audiometric thresholds to demonstrate changes in the auditory system. However, to help determine the effects on outer hair cells (OHCs), a more sensitive measure should be used. The purpose of this study was to determine if supplemental magnesium administration prior to noise exposure has a beneficial effect on acoustic overexposure using a double-blind research design. This was determined by measuring distortion product otoacoustic emissions (DPOAEs) to determine any changes in cochlear OHC function. DPOAE amplitude and signal-to-noise ratio (SNR) measurements were analyzed for two groups of twenty participants (an experimental group and a control group). The experimental group received 150 mg of magnesium gluconate one hour prior to noise exposure. The control group received a placebo pill that was identical in appearance to the magnesium pill. Following noise exposure, the greatest changes in DPOAE amplitude and SNR occurred for the frequencies that were one-half to one octave above the frequency of the stimuli used. The greatest changes in DPOAE measurements were present immediately post TTS-inducing stimulus, with only slight changes present after 30 minutes and no difference between 30 minutes and 60 minutes post-exposure. These results were the same for both groups. It was concluded that this dosage of supplemental magnesium had no apparent protective effect on DPOAEs following intense noise exposure.
125

Hearing evaluation in infants [electronic resource] : an update for pediatricians / by Janet E. Sullivan.

Sullivan, Janet E. January 2003 (has links)
Professional research project (Au.D.)--University of South Florida, 2002. / Title from PDF of title page. / Document formatted into pages; contains 48 pages. / Includes bibliographical references. / Text (Electronic thesis) in PDF format. / ABSTRACT: This paper provides an overview of developmental timetables relevant to hearing and of current pediatric audiological techniques and practices. The first sections summarize structural and functional development of the auditory pathway and the development of primary auditory processing. These developmental sequences appear to follow similar paths in humans and animals. Speech and music perception involve more complex processing and are strongly influenced by experience. Hearing disorders affect the perception of complex sounds in a variety of ways, depending on the site(s) of lesions. Early onset hearing impairment, including conductive loss from chronic otitis media, can seriously impede language development. Language cannot develop normally without adequate speech stimulation. / ABSTRACT: Sensitive and inexpensive techniques are available for performing neonatal hearing screening, and early intervention has a positive effect on development of language skills in hearing-impaired children. Thus, the National Institute of Health has recommended nationwide universal newborns hearing screening. The rationale and methodology of universal screening programs is summarized in the chapter. Advances in the field of the genetics of hearing impairment are also reviewed / System requirements: World Wide Web browser and PDF reader. / Mode of access: World Wide Web.
126

Otoskopische und histologische Untersuchungen des Pferdeohres im Rahmen der Anpassung objektiver Hörfunktionsdiagnostik / Otoscopic and histological examinations of the equine acoustic organ in line with the adaption of objective diagnostic audiometric testing

Blanke, Annemarie 03 June 2015 (has links) (PDF)
In der veterinärmedizinischen Wissenschaft spielt das equine akustische Organ sowie dessen Erkrankungen und Funktionsstörungen bislang eine stark untergeordnete Rolle. Mangelnde Visualisierungs- und Untersuchungsmöglichkeiten, geringe Patienten- Compliance sowie fehlende Referenzen erschweren die Diagnose aurikulärer Erkrankungen (SARGENT et al. 2006; SOMMERAUER et al. 2012). Das übergeordnete langfristige Ziel dieser Forschungsarbeit ist es, humanmedizinische objektive audiometrische Messtechnik an das Pferdeohr anzupassen. Von speziellem Interesse ist dabei die Messung otoakustischer Emissionen zur objektiven Überprüfung der Innenohrfunktion. Die grundlegende Voraussetzung jeglicher Messungen und Adaptierungen ist zunächst die otoskopische Kontrolle des externen Gehörkanales und Trommelfelles. So können die Messung behindernde Faktoren, beispielsweise ein hoher Verschmutzungsgrad oder Fremdkörper im externen Gehörkanal, ausgeschlossen werden. Mit Hilfe herkömmlicher Videobronchoskope oder Videogastroskope (Durchmesser von 7 mm bzw. 9 mm) und der Anwendung eines standardisierten Protokolls konnten im Rahmen der Basisstudie die externen Gehörkanäle und Trommelfelle von 38 sedierten Pferden bilateral endoskopisch untersucht werden. Aus praktischer Sicht ist dabei hervorzuheben, dass die bislang obligatorische Leitungsanästhesie der Ohrnerven und das damit verbundene Risiko einer Fazialisparese vollständig umgangen werden konnte. Im Zuge dieses optimierten Verfahrens wurden physiologische und pathologische endoskopische Referenzen des externen Gehörkanales und Trommelfelles erstellt. Pathologische otoskopische Befunde (z.B. Tympanosklerose) sowie mangelnde veterinärmedizinische Fachliteratur verdeutlichen den Bedarf der histologischen Aufarbeitung des equinen akustischen Organs. Im Rahmen der Folgestudie wurden die Ohren von zehn Schlachtpferden für die detaillierte histologische Aufarbeitung herangezogen. Die Ergebnissedieser Arbeit beschreiben und verbildlichen erstmalig das vollständige equine akustische Organ. Im Folgenden sind nun die wesentlichen Ergebnisse der Basis- und Folgestudie zusammengefasst. Der physiologische kartilaginöse externe Gehörkanal ist pigmentiert, mit Haaren sowie mit cerumenproduzierenden Talg- und Schweißdrüsen ausgekleidet. Im Vergleich zum ossären externen Gehörkanal weist der kartilaginöse Anteil einen deutlich höheren Verschmutzungsgrad auf. Der Übergang zwischen dem kartilaginösen und ossären äußeren Gehörgang ist histologisch gekennzeichnet durch einen abrupten Wechsel zu einem unpigmentierten, haarlosen und drüsenfreien mehrschichtig verhornten Epithel. Endoskopisch ist dieser Übergang anhand kranzartig angeordneter beigefarbener Keratinschuppen erkennbar, welche Produkte des Selbstreinigungsmechanismus des knöchernen Gehörganges darstellen. Letzterer besitzt eine rund-ovale Form, ein trockenes zartrosafarbenes Epithel mit konzentrischen Keratinringen und schwach durchscheinender Gefäßzeichnung. Das physiologische equine Trommelfell stellt sich endoskopisch als eine klar in ihre Bestandteile (Pars tensa, Pars flaccida, Stria mallearis) differenzierte semitransparente Membran ohne positiven Lichtreflex dar. Auf der Grundlage der etablierten physiologischen Referenzen konnten pathologische Befunde bei sieben Pferden (vier Pferde mit Aural Plaques, drei Pferde mit Otitis externa) nachgewiesen werden. Zu den typischen Kennzeichen einer Otitis externa zählen die Schwellung und Rötung des ossären Epithels, das Verstreichen der konzentrischen Keratinringe und/oder die Ablösung der schützenden Keratinschicht im ossären Gehörkanal sowie ein positiver Lichtreflex im Bereich des Trommelfelles. Bei einem der an Otitis externa erkrankten Pferde konnte ein möglicher Zusammenhang zu einer Temporohyoidosteoarthropathie (THO) hergestellt werden. Darüber hinaus konnte bei zwei weiteren Pferden erstmalig eine Tympanosklerose diagnostiziert werden. Die Resultate dieser Dissertation liefern die Grundlage für weitere Forschungsansätze auf dem Gebiet des equinen akustischen Organs. Die Ohrendoskopie am stehenden sedierten Pferd ist eine praktikable, schonende sowie diagnostisch wertvolle Untersuchungsmöglichkeit. Sie sollte insbesondere bei der Abklärung einer THO, Fazialisparese, Vestibularsyndrom, Headshaking, Kopfscheue, parasitären Infektionen oder bei Kopftraumata zum Einsatz kommen. Die Ohrendoskopie ist zudem der Ausgangspunkt für die Anpassung und Anwendung humanmedizinischer audiometrischer Messsonden an das Pferdeohr. Die gewonnenen histologischen Erkenntnisse bilden die Basis für weiterführende Untersuchungen hinsichtlich angeborener oder erworbener Mittel- und Innenohrerkrankungen, welche Einfluss auf die Messung der otoakustischen Emissionen haben. / The equine acoustic organ, including its diseases and disorders, still plays a minor role in veterinary science. Due to insufficient visualization and examination equipment, little patient compliance and sparse references the diagnosis of auricular diseases is rather difficult (SARGENT et al. 2006; SOMMERAUER et al. 2012). The overall aim of this research project is to adapt human objective audiometric testing devices onto the equine acoustic organ. Particularly, the measurement of so-called otoacoustic emissions is of importance for an objective evaluation of the inner ear function. The otoscopic examination of the external ear canal and tympanic membrane is the fundamental precondition for the adaption of probes and every audiometric testing. Circumstances that may prevent us from having successful measurements, like a high degree of ceruminous and cellular debris or even foreign bodies within the external ear canal, can be identified and eliminated by otoscopy. By the use of common veterinary videobronchoscopes or videogastroscopes (calibre 7 mm/9 mm) the external ear canal and tympanic membrane of 38 standing sedated horses were bilaterally examined following a standardized protocol. Special emphasis should be placed on the fact that the obligatory local nerve block anaesthesia of the auricular nerves and the associated risk of a facial nerve paralysis were completely eliminated. With the help of this simplified procedure physiological and pathological references could be established. Pathological findings and a lack of relevant veterinary literature prompted us to take a closer look at histological aspects of the equine acoustic organ. In this context, the ears of ten slaughter horses were histologically examined in detail. The results of this follow-up study describe and illustrate the complete histology of the equine acoustic organ for the first time. In the following the essential results of the basic- and follow-up study are summarized. The physiological cartilaginous external ear canal is pigmented and contains hair, as well as ceruminous and sebaceous glands. In comparison to the osseous external ear canal, the cartilaginous part has higher degree of ceruminous and cellular debris. The intersection between both- the cartilaginous and osseous portion- is histologically characterized by an abrupt change to a non-pigmented, hairless, aglandular keratinized stratified squamous epithelium. Endoscopically, the intersection can be identified by a rim of beige keratin scales, which are products of the self-cleaning mechanism of the osseous epithelium. The osseous ear canal is round to oval shaped and lined with pale pink coloured epithelium that contains concentric keratin formations and visible capillary drawing. The physiological equine tympanic membrane is endoscopically characterized by a well-differentiated semi- transparent membrane, which shows no positive light reflex. On basis of the established physiological references pathological changes were found in seven horses (four horses with aural plaques, three horses with otitis externa). Typical sings of otitis externa were swelling and reddening of the osseous epithelium, the loss of the concentric keratin layer formation and/or detachment of the protective osseous keratin layer, as well as a positive light reflex on the tympanic membrane. In one diseased horse a possible correlation between the Otitis externa and severe temporohyoid osteoarthropathy (THO) could be revealed. Additionally, tympanosclerotic changes within two equine eardrums could be visualized for the first time. The results of this study provide a basis for further research on the equine acoustic organ. The otoscopic examination in standing sedated horses is a viable, safe, easy and quick to perform beneficial diagnostic procedure for a complete work-up of ear-related diseases, such as THO, facial nerve paralysis, vestibular disease, head shaking, parasitic infections or head trauma. In addition, the otoscopic examination is a basic requirement for the adaption and the use of human audiometric measuring probes in equine ears. The results obtained in the histological study can be employed as references for further research on equine congenital and acquired middle and inner ear diseases, which can influence the measurement results of otoacoustic emissions.
127

Mathematical modelling and electrophysiological monitoring of the regulation of cochlear amplification

O'Beirne, Greg A. January 2005 (has links)
[Truncated abstract] The cochlea presumably possesses a number of regulatory mechanisms to maintain cochlear sensitivity in the face of disturbances to its function. Evidence for such mechanisms can be found in the time-course of the recovery of CAP thresholds during experimental manipulations, and in observations of slow oscillations in cochlear micromechanics following exposure to low-frequency tones (the “bounce phenomenon”) and other perturbations. To increase our understanding of these oscillatory processes within the cochlea, and OHCs in particular, investigations into cochlear regulation were carried out using a combination of mathematical modelling of the ionic and mechanical interactions likely to exist within the OHCs, and electrophysiological experiments conducted in guinea pigs. The electrophysiological experiments consisted of electrocochleographic recordings and, in some cases, measurement of otoacoustic emissions, during a variety of experimental perturbations, including the application of force to the cochlear wall, exposure to very-low-frequency tones, injection of direct current into scala tympani, and intracochlear perfusions of artificial perilymph containing altered concentrations of potassium, sodium, and sucrose. To obtain a panoramic view of cochlear regulation under these conditions, software was written to enable the interleaved and near-simultaneous measurement of multiple indicators of cochlear function, including the compound action potential (CAP) threshold, amplitude and waveshape at multiple frequencies, the OHC transfer curves derived from low-frequency cochlear microphonic (CM) waveforms, distortion-product otoacoustic emissions (DPOAEs), the spectrum of the round-window neural noise (SNN), and the endocochlear potential (EP). ... The mathematical model we have developed provided a physiologically-plausible and internally-consistent explanation for the time-courses of the cochlear changes observed during a number of different perturbations. We show that much of the oscillatory behaviour within the cochlea is consistent with underlying oscillations in cytosolic calcium concentration. We conclude that a number of the discrepancies between the simulation results and the experimental data can be resolved if the cytosolic calcium functions as two distinct pools: one which controls basolateral permeability and one which controls slow motility. This two-calcium-pool model is discussed.
128

DPOAE two-source separation in adult Japanese quail (Coturnix coturnix japonica) /

Belzner, Katharine Ann. January 2010 (has links) (PDF)
Thesis (Ph.D.)--James Madison University, 2010. / Includes bibliographical references.
129

Supressão das emissões otoacústicas e sensibilização do reflexo acústico no distúrbio de processamento auditivo / Otoacoustic emission suppression and acoustic reflex sensitization in auditory processing disorders

Fernanda Acaui Ribeiro Burguetti 12 March 2007 (has links)
INTRODUÇÃO: O processamento da informação sonora depende da integridade das vias auditivas. O sistema auditivo eferente pode ser avaliado por meio de dois métodos objetivos e não-invasivos: a obtenção dos limiares dos reflexos acústicos, e a supressão das emissões otoacústicas. OBJETIVO: Verificar a atividade do sistema auditivo eferente, por meio da supressão das emissões otoacústicas por transientes (EOAT) e da sensibilização do reflexo acústico em indivíduos com alteração de processamento auditivo. MÉTODO: Foram avaliadas 50 crianças com alteração de processamento auditivo (grupo estudo) e 38 crianças sem alteração de processamento auditivo (grupo controle), por meio das EOAT evocadas por \"clicks\" na ausência e na presença de ruído ipsilateral e contralateral, e por \" tone bursts\", nas freqüências de 1000, 2000 e 4000 Hz na ausência e na presença de ruído contralateral, e de reflexo acústico nas freqüências de 500, 1000, 2000 e 4000 Hz na ausência e na presença de estímulo facilitador ipsi e contralateral. RESULTADOS: O valor da média de EOAT evocadas por \"clicks\" com estímulo supressor foi de até 1,50 dB para o grupo controle e de até 1,26 dB para o grupo estudo. Para as EOAT evocadas por \"tone bursts\" com estímulo supressor, os valores médios foram de até 2,69 dB para o grupo controle e de até 2,79 dB para o grupo estudo. Foi observado efeito de sensibilização do reflexo acústico com redução média de até 18,17 dB para o grupo estudo e de até 17,38 dB para o grupo controle. Não foi observada diferença estatisticamente significante entre as respostas do grupo controle e do grupo estudo, para supressão de EOAT (exceto na freqüência de 2000 Hz - \"tone burst\"), e para sensibilização do reflexo acústico. CONCLUSÕES: O grupo estudo apresentou valores reduzidos na pesquisa de supressão das EOAT e valores aumentados na sensibilização do reflexo acústico, em relação ao grupo controle. / INTRODUCTION: Auditory processing depends on the auditory pathways integrity. Efferent auditory system may be assessed in humans by two non-invasive and objective methods: acoustic reflex and otoacoustic emissions suppression. OBJECTIVE: Analyze efferent auditory system activity by otoacoustic emissions suppression and acoustic reflex sensitization in human subjects with auditory processing disorders. METHOD: Fifty children with auditory processing disorders (study group) and thirty-eight children without auditory processing disorders (control group) have being evaluated using clicks otoacoustic emission suppression with and without ipsilateral and contralateral white noise; tone bursts otoacoustic emission suppression in 1000, 2000 and 4000 Hz with and without contralateral white noise and acoustic reflex in 500, 1000, 2000 and 4000 Hz with and without ipsilateral and contralateral facilitator. RESULTS: The higher clicks otoacoustic emission suppression was up to 1.50 dB for the control group and up to 1.26 dB for the study group. The higher tone burst otoacoustic emission was up to 2.69 dB for the control group and up to 2.79 dB for the study group. The higher acoustical reflex sensitization was up to 18.17 dB for the study group and up to 17.38 dB for the control group. There was no significant statistical difference between results for control group and study group to otoacoustic emission suppression (except for 2000 Hz) and acoustical reflex sensitization. CONCLUSION: Study group presented smaller otoacoustic emission suppression than control group and study group presented higher acoustical reflex sensitization than control group.
130

Especificidade e taxa de falso-positivo em três protocolos de triagem auditiva neonatal / Specificity and false-positive rate in three newborn hearing screening protocols

Vanessa Sabino de Freitas 24 November 2006 (has links)
O objetivo do presente estudo foi estimar a especificidade e taxa de falso-positivo de protocolos de triagem auditiva neonatal (TAN), realizados com os procedimentos emissões otoacústicas evocadas transientes-módulo triagem (EOAet) e potenciais evocados auditivos de tronco encefálico automático (PEATEa), de forma isolada ou combinada, aplicados em uma ou duas etapas. Participaram deste estudo 200 recém-nascidos, selecionados aleatoriamente, submetidos à triagem auditiva, no período entre Março/2006 e Julho/2006. A estimativa da taxa de falso-positivo e da especificidade foi realizada com a TAN em uma etapa e com três protocolos: protocolo 1, TAN realizada em duas etapas com EOAet; protocolo 2, TAN realizada em duas etapas com PEATEa; e protocolo 3, TAN realizada em uma etapa com dois procedimentos - teste com EOAet seguido de reteste com PEATEa para os recém-nascidos que não passaram no primeiro procedimento. Os resultados mostraram alta taxa de falso-positivo na triagem auditiva realizada em uma etapa para ambos os procedimentos. Apesar de não ter havido diferença estatisticamente significante quando comparadas as taxas de encaminhamento para diagnóstico audiológico obtidos nos protocolos com EOAet e com PEATEa, o protocolo com EOAet encaminhou 4 vezes mais recém-nascidos. O protocolo com EOAet e PEATEa apresentou a maior taxa de encaminhamento (6%), com diferença estatisticamente significante ao ser comparado com os protocolos 1 (EOAet) e 2 (PEATEa). Concluiu-se que a triagem auditiva neonatal deve ser realizada em duas etapas (teste-reteste), a fim de reduzir a taxa de falso-positivo e de encaminhamento, aumentando a especificidade; a taxa de falso-positivo e conseqüentemente a especificidade foram melhores no protocolo com PEATEa, seguido dos protocolos com EOAet e com EOAet e PEATEa. / O objetivo do presente estudo foi estimar a especificidade e taxa de falso-positivo de protocolos de triagem auditiva neonatal (TAN), realizados com os procedimentos emissões otoacústicas evocadas transientes-módulo triagem (EOAet) e potenciais evocados auditivos de tronco encefálico automático (PEATEa), de forma isolada ou combinada, aplicados em uma ou duas etapas. Participaram deste estudo 200 recém-nascidos, selecionados aleatoriamente, submetidos à triagem auditiva, no período entre Março/2006 e Julho/2006. A estimativa da taxa de falso-positivo e da especificidade foi realizada com a TAN em uma etapa e com três protocolos: protocolo 1, TAN realizada em duas etapas com EOAet; protocolo 2, TAN realizada em duas etapas com PEATEa; e protocolo 3, TAN realizada em uma etapa com dois procedimentos - teste com EOAet seguido de reteste com PEATEa para os recém-nascidos que não passaram no primeiro procedimento. Os resultados mostraram alta taxa de falso-positivo na triagem auditiva realizada em uma etapa para ambos os procedimentos. Apesar de não ter havido diferença estatisticamente significante quando comparadas as taxas de encaminhamento para diagnóstico audiológico obtidos nos protocolos com EOAet e com PEATEa, o protocolo com EOAet encaminhou 4 vezes mais recém-nascidos. O protocolo com EOAet e PEATEa apresentou a maior taxa de encaminhamento (6%), com diferença estatisticamente significante ao ser comparado com os protocolos 1 (EOAet) e 2 (PEATEa). Concluiu-se que a triagem auditiva neonatal deve ser realizada em duas etapas (teste-reteste), a fim de reduzir a taxa de falso-positivo e de encaminhamento, aumentando a especificidade; a taxa de falso-positivo e conseqüentemente a especificidade foram melhores no protocolo com PEATEa, seguido dos protocolos com EOAet e com EOAet e PEATEa.

Page generated in 0.0913 seconds