141 |
Distorções harmônicas produzidas por inversores de geração distribuída fotovoltaica em condição de ressonância paralela / Harmonic distortion produced by inverters photovoltaic distributed generation in parallel resonance conditionFortes, Rárison Roberto Acácio [UNESP] 12 March 2016 (has links)
Submitted by RARISON ROBERTO ACACIO FORTES null (rarisonfortes@yahool.com) on 2016-05-05T14:43:06Z
No. of bitstreams: 1
RFortes.pdf: 3576878 bytes, checksum: 1f31f85eeeb5bf64f3b8b9781d51941c (MD5) / Approved for entry into archive by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br) on 2016-05-09T13:45:49Z (GMT) No. of bitstreams: 1
fortes_rra_me_ilha.pdf: 3576878 bytes, checksum: 1f31f85eeeb5bf64f3b8b9781d51941c (MD5) / Made available in DSpace on 2016-05-09T13:45:49Z (GMT). No. of bitstreams: 1
fortes_rra_me_ilha.pdf: 3576878 bytes, checksum: 1f31f85eeeb5bf64f3b8b9781d51941c (MD5)
Previous issue date: 2016-03-12 / Fundação de Amparo à Pesquisa do Estado do Acre (FAPAC) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Como os sistemas de energia têm sido tradicionalmente projetados para produção centralizada, a penetração de sistemas de geração distribuída na rede tem causado mudança nesse perfil, criando novos desafios operacionais que se fazem importantes para a reestruturação dos sistemas tradicionais. No entanto, este novo cenário do sistema elétrico, introduzido pela resolução 482/2012 da Agência Nacional de Energia Elétrica – ANEEL, trouxe às distribuidoras de energia um novo panorama para as atividades de operação e manutenção de suas redes e ativos, principalmente devido à bidirecionalidade do fluxo de potência na rede, originado pela conexão de sistemas de geração distribuída. Os impactos técnicos devem ser previstos e analisados, sobretudo em redes de distribuição, para garantir os padrões mínimos de qualidade da energia no ponto de consumo e evitar o comprometimento das cargas alimentadas. Dentre os impactos, destaca-se o efeito sobre os bancos de capacitores devido à injeção de distorções harmônica produzida pelos inversores de sistemas fotovoltaicos, que sob certas condições, produzem conteúdo harmônico com nível acima do limite normatizado, podendo excitar uma condição prévia de ressonância no barramento. Neste contexto, esta dissertação tem como principal objetivo analisar o comportamento do sistema elétrico em condição de ressonância paralela e avaliar o grau de comprometimento dos bancos de capacitores instalados no sistema de distribuição com presença de frequências harmônicas e sugerir rotinas técnicas para evitar sua operação contingenciada. / As energy systems have been traditionally projected for centralized production, the penetration of distributed generation systems have caused a change in this profile, creating new operational challenges that are important for traditional systems restructuring. However, this new electrical system scenario, introduced by resolution 482/2012 of Brazilian Electricity Regulatory Agency – ANEEL, brought to energy distributors a new view to the operational and maintenance activities of their nets and actives, specially due to the net power flow bidirectionality, created by the distributed generation systems connection. Technical impacts must be estimated and analyzed, specially in distribution nets, to ensure minimum energy quality standards in the consumption point and avoid fed charges commitment. Among the impacts stands out the capacitor bench effects due to harmonic distortions injection produced by photovoltaic systems inverters, that under some conditions, produce harmonic content over the regulated limit, being able to excite a preview condition of resonance in the bus. In this context, this essay has the main objective to analyze the electrical system behavior in parallel resonance condition and evaluate the degree of commitment of the capacitor bench installed in the distribution system with harmonic frequencies and suggest technical routines to avoid the contingent operation. / FAPAC: 6068-14-0000093
|
142 |
Desenvolvimento de um inversor fotovoltaico trifásico não isolado conectado à rede elétrica / Development of a grid-connected transformerless three-phase photovoltaic inverterGiacomini, Julian Cezar 09 March 2015 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This Master Thesis presents the development of a grid-connected transformerless
three-phase photovoltaic inverter. The Neutral Point Clamped (NPC) three-level inverter was
chosen for implementation. The grid connection is made with a modified LCL filter (MLCL),
where the common point of the output filter capacitors is connected directly to the dc bus
central point (neutral point). The MLCL filter reduces the leakage current of photovoltaic
system and attenuates the current harmonics injected in the grid. A passive damping of MLCL
filter resonance peak was employed in order to avoid instability in the grid connection. In this
sense, this Master Thesis contributes proposing a passive damping design method which is
based not only on the stability requirement, but also considers the leakage current of
photovoltaic system, once that passive damping impacts on the high frequency components of
voltage on parasitic capacitance. Therefore, based on leakage current limit and current loop
stability, a range for the damping resistance was obtained. The control system of the threephase
inverter was developed in a synchronous reference frame (dq0), where the proper
alignment with the grid voltage reference vector allows the independent control of active and
reactive power inject in the grid. Simulation and experimental results are shown to evaluate
the inverter performance and to validate the theoretical analysis. / Esta Dissertação de Mestrado apresenta o desenvolvimento de um inversor
fotovoltaico trifásico não isolado conectado à rede. A topologia desenvolvida foi a de um
inversor trifásico três níveis com ponto neutro grampeado (NPC Neutral Point Clamped). A
conexão com a rede é feita através de um filtro LCL modificado (LCLM), que possui o ponto
comum dos seus capacitores conectado ao ponto central do barramento CC do inversor. O
filtro LCLM possui a finalidade de reduzir a corrente de fuga do sistema fotovoltaico ao
mesmo tempo em que atenua os harmônicos de corrente injetados na rede. De modo a evitar
problemas de instabilidade da malha de corrente do inversor, um sistema de amortecimento
passivo do pico de ressonância do filtro LCLM foi empregado. Neste sentido, esta Dissertação
de Mestrado contribui propondo um método de projeto do amortecimento passivo que se
baseia não somente no critério de estabilidade, mas que também considera a corrente de fuga
do sistema fotovoltaico, uma vez que o amortecimento impacta na atenuação das
componentes de alta frequência da tensão sobre a capacitância parasita dos módulos
fotovoltaicos. Com isso, uma faixa de valores para a resistência de amortecimento foi obtida a
partir do limite permitido para a corrente de fuga e da estabilidade da malha de corrente. O
sistema de controle do inversor trifásico foi desenvolvido com base no sistema de
coordenadas síncronas dq0, cujo correto alinhamento com o vetor de referência das tensões da
rede permite o controle independente das potências ativa e reativa injetadas na rede.
Resultados experimentais e de simulação são apresentados de modo a comprovar o
desempenho do inversor trifásico.
|
143 |
Distorções harmônicas produzidas por inversores de geração distribuída fotovoltaica em condição de ressonância paralela /Fortes, Rárison Roberto Acácio January 2016 (has links)
Orientador: Luís Carlos Origa de Oliveira / Resumo: Como os sistemas de energia têm sido tradicionalmente projetados para produção centralizada, a penetração de sistemas de geração distribuída na rede tem causado mudança nesse perfil, criando novos desafios operacionais que se fazem importantes para a reestruturação dos sistemas tradicionais. No entanto, este novo cenário do sistema elétrico, introduzido pela resolução 482/2012 da Agência Nacional de Energia Elétrica – ANEEL, trouxe às distribuidoras de energia um novo panorama para as atividades de operação e manutenção de suas redes e ativos, principalmente devido à bidirecionalidade do fluxo de potência na rede, originado pela conexão de sistemas de geração distribuída. Os impactos técnicos devem ser previstos e analisados, sobretudo em redes de distribuição, para garantir os padrões mínimos de qualidade da energia no ponto de consumo e evitar o comprometimento das cargas alimentadas. Dentre os impactos, destaca-se o efeito sobre os bancos de capacitores devido à injeção de distorções harmônica produzida pelos inversores de sistemas fotovoltaicos, que sob certas condições, produzem conteúdo harmônico com nível acima do limite normatizado, podendo excitar uma condição prévia de ressonância no barramento. Neste contexto, esta dissertação tem como principal objetivo analisar o comportamento do sistema elétrico em condição de ressonância paralela e avaliar o grau de comprometimento dos bancos de capacitores instalados no sistema de distribuição com presença de frequências harmô... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: As energy systems have been traditionally projected for centralized production, the penetration of distributed generation systems have caused a change in this profile, creating new operational challenges that are important for traditional systems restructuring. However, this new electrical system scenario, introduced by resolution 482/2012 of Brazilian Electricity Regulatory Agency – ANEEL, brought to energy distributors a new view to the operational and maintenance activities of their nets and actives, specially due to the net power flow bidirectionality, created by the distributed generation systems connection. Technical impacts must be estimated and analyzed, specially in distribution nets, to ensure minimum energy quality standards in the consumption point and avoid fed charges commitment. Among the impacts stands out the capacitor bench effects due to harmonic distortions injection produced by photovoltaic systems inverters, that under some conditions, produce harmonic content over the regulated limit, being able to excite a preview condition of resonance in the bus. In this context, this essay has the main objective to analyze the electrical system behavior in parallel resonance condition and evaluate the degree of commitment of the capacitor bench installed in the distribution system with harmonic frequencies and suggest technical routines to avoid the contingent operation. / Mestre
|
144 |
Degradação induzida pelo potencial em módulos e instalações fotovoltaicas de c-Si / Potential induced degradation on c-Si photovoltaic modules and installationsGilberto Figueiredo Pinto Filho 14 November 2017 (has links)
Este trabalho apresenta abordagens para a avaliação do fenômeno da Degradação Induzida pelo Potencial (PID do inglês Potential Induced Degradation) em módulos e instalações fotovoltaicas de c-Si. Nos ensaios em laboratório, a IEC TS 62804-1:2015 foi aplicada e ações adicionais são sugeridas como forma de adaptação da especificação técnica para o acompanhamento da degradação durante o ensaio e para melhor indicar a propensão do equipamento a se recuperar das consequências da aparição de PID. Nos ensaios em campo, avaliou-se a solução convencional do mercado de reverter a degradação através de circuitos anti-PID, além de apresentar a aplicação de técnicas de detecção do fenômeno em sistemas operacionais. A abordagem teórica e os resultados práticos mostram que o procedimento de aferição de tensões individuais de operação é um método útil para detectar PID. Os estudos de caso apresentados indicam que esta metodologia é eficaz inclusive na detecção precoce do fenômeno para diferentes topologias de células fotovoltaicas de c-Si. / This work presents approaches to assess the Potential Induced Degradation (PID) on c-Si photovoltaic modules and installations. The IEC TS 62804-1:2015 was applied to the laboratory tests and some additional actions are suggested. The adaptation of the technical specification aims to monitor the degradation rates during the tests and also to consider the capacity of the photovoltaic modules to recover from the degradation. In the field detection methodologies are presented and anti-PID circuits were also tested. The theoretical approach reveals that individual voltage measurements are useful to detect PID even in its early stage, as can be seen on the case studies presented.
|
145 |
Otimização da forma para captação da radiação solar sobre superfícies de edifícios : um exercício de integração entre os programas Rhinoceros e EcotectVannini, Virgínia Czarnobay January 2011 (has links)
Este trabalho tem como objetivo explorar a forma de planos de fachada vinculados à incidência solar, potencializando a aplicação de sistemas fotovoltaicos. A identificação e parametrização de formas segundo os princípios geométricos de captação fotovoltaica, sugerem a aplicação de uma metodologia de projeto para superfícies de fachadas fotovoltaicas, de modo a otimizar a incidência direta da radiação solar, incorporada a volumetria da edificação. O modelo de otimização de fachadas fotovoltaicas consiste em quatro etapas. Inicialmente define-se a tecnologia fotovoltaica e a localização geográfica (1). Posteriormente, é realizada a modelagem elementar tridimensional (2) através do editor de algoritmos gráficos Grasshopper – integrado à ferramenta de modelagem Rhinoceros3D – estabelecendo assim, as restrições e variáveis da forma. Na terceira etapa, correlacionamse transformações geométricas tridimensionais (twist, taper e shear) e incidência solar (3) por meio dos softwares Ecotect Analysis e Grasshopper. Com isso, os parâmetros dimensionais atribuídos às variáveis – transformações geométricas – são vinculados aos parâmetros de radiação solar, visando à geração de formas. Após a seleção das formas com maior potencial fotovoltaico, identificam-se as zonas com maior incidência de radiação solar e realiza-se a manipulação dos pontos de controle das superfícies NURBS (4). Através das transformações geométricas taper, shear e twist foi possível gerar um conjunto de soluções otimizadas, correlacionando dados energéticos e geométricos, integrando métodos de geração de formas e avaliação performática da radiação solar. O estudo identificou que as possibilidades de articulação entre os planos fotovoltaicos e a eficiência energética têm implicações positivas, correlacionando variabilidade formal e geração de energia elétrica. / This work aims explore the shape of façade planes linked to the solar incidence, in order to optimize the use of photovoltaic systems. The identification and parameterization of forms according to geometric principles of photovoltaic capture suggest the application of a design methodology for optimizing the photovoltaic surface façade in order to optimize direct solar radiation, incorporating the volume of the building. The optimization model of photovoltaic façade consists of four steps. Initially decide on the photovoltaic technology and geographic location (1). Subsequently, three-dimensional elementary modeling is performed (2) through the graphic-algorithm editor, Grasshopper, – integrated with the modeling tool, Rhinoceros 3D, – thus establishing, restrictions and variables in shape. In the third stage, threedimensional geometric transformations are correlated (twist, taper and shear) and solar incidence (3) through the computer interfaces of Ecotect Analysis and Grasshopper software. With this, the dimensional parameters assigned to the variables – geometric transformations – are linked to parameters of solar radiation, in order to generate shapes. After the selection of potential photovoltaic shapes, zones with the greatest incident solar radiation are identified and the control points of NURBS surface are manipulated (4). Using the geometric transformations taper, shear and twist, it was possible to generate a set of optimal solutions, correlating geometric and energetic data, integrating shape generating methods and performatic evaluation of solar exposure. The work identified that possibilities of articulation between photovoltaic planes and energetic efficiency have positive results, correlating shape variability and electricity generation.
|
146 |
Técnicas de seguimento do ponto de máxima potência para sistemas fotovoltaicos com sombreamento parcialFURTADO, Artur Muniz Szpak 26 February 2016 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2016-09-12T14:19:20Z
No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Artur_Muniz_Dissertacao_Digital_Biblioteca.pdf: 14042205 bytes, checksum: 21290a8d10774b2848f16e9351043b9a (MD5) / Made available in DSpace on 2016-09-12T14:19:20Z (GMT). No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Artur_Muniz_Dissertacao_Digital_Biblioteca.pdf: 14042205 bytes, checksum: 21290a8d10774b2848f16e9351043b9a (MD5)
Previous issue date: 2016-02-26 / FACEPE / A curva da potência em função da tensão nos terminais de uma conexão em série de módulos
fotovoltaicos, com diodos de passagem protetores, exposta a um sombreamento parcial, exibe
um comportamento com múltiplos picos. Os múltiplos picos tornam as estratégias clássicas
de seguimento do ponto de máxima potência, ou MPPT, ineficazes. Em primeiro momento,
este trabalho realiza uma análise estatística que determina uma região trapezoidal no plano
tensão potência onde o ponto de máxima potência global está inserido para qualquer situação
de irradiâncias múltiplas e temperatura, para configurações com inversor central e módulos
conectados em séries puras ou conectadas em paralelo. Em segundo momento, este trabalho
pesquisa as técnicas de MPPT Global que rastreiam o ponto de máxima potência global de uma
curva tensão potência com múltiplos picos. Duas destas técnicas são estudadas a fim de avaliar a
rapidez em encontrar o ponto de máxima potência global e a energia perdida na busca. Por fim, é
proposta uma nova técnica de MPPT Global baseada no estudo estatístico preliminar. Esta nova
técnica é proposta tirando proveito do trapézio delimitado na análise estatística. / The power-voltage characteristic of series arrays of photovoltaic modules with bypass diodes
under partial shading conditions, displays a multiple peaks behavior. The multiple peaks make
the classical algorithms of maximum power point tracking, or MPPT, ineffective. At first, this
work performs a statistical analysis that determines a trapezoidal region in the power voltage plan
where the global maximum power point is situated for any situation from multiple irradiances
and any temperature, for central inverter configuration with a series array of modules or parallel
connected series arrays. Soon after, this paper researches the Global MPPT techniques that track
the global maximum power point of power-voltage curves with multiple peaks. Some of these
techniques are studied to assess how fast they can find the global maximum power point and
the energy lost at this search. Finally, it is proposed a new Global MPPT technique based on the
preliminary statistical study. This new technique is proposed taking advantage of the trapezoidal
region defined in the statistical analysis.
|
147 |
Dimensionamento de um sistema fotovoltaico conectado à rede a partir das características de inclinação e orientação dos módulos fotovoltaicos / Design of a grid-connected photovoltaic system from the photovoltaic modules tilt and azimuth angles characteristicsPaiva, Gabriel Mendonça de 03 June 2016 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2016-10-18T20:19:54Z
No. of bitstreams: 2
Dissertação - Gabriel Mendonça de Paiva - 2016.pdf: 3565340 bytes, checksum: 6df5384c34ed001061350c147d523756 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Erika Demachki (erikademachki@gmail.com) on 2016-10-19T16:18:31Z (GMT) No. of bitstreams: 2
Dissertação - Gabriel Mendonça de Paiva - 2016.pdf: 3565340 bytes, checksum: 6df5384c34ed001061350c147d523756 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2016-10-19T16:18:31Z (GMT). No. of bitstreams: 2
Dissertação - Gabriel Mendonça de Paiva - 2016.pdf: 3565340 bytes, checksum: 6df5384c34ed001061350c147d523756 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Previous issue date: 2016-06-03 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / This study aimed to evaluate the design of a grid-connected photovoltaic (PV) system
according to the positioning of the modules which compose the generator depending on tilt
and azimuth angles in Goiânia, Goiás. In that purpose, a review of the literature was carried
out concerning the main methods of inverter sizing ratio analysis applied to grid-connected
PV systems. Starting from an hourly average climate measurement database from Goiania, an
algorithm was developed to search for the ideal local inverter sizing ratio, considering the
use of polycrystalline module technology. The parameters used in the analysis were provided
by the manufacturers of the componentes used in the grid-connected PV system in installation
at the Electrical, Mechanical and Computational Engineering School (EMC) from Federal
University of Goias (UFG), which nominal power is 33.84 kWp. An inverter sizing ratio band
of 0.54 to 0.77 was obtained for a -90° to +90° azimuth angle variation and 0° to 90° tilt
angle variation. The potential of financial indicators improvement was verified and it was
estimated a potential reduction in the levelized cost of energy above 10% comparing the
inverter sizing ratio improved system to an unitary inverter sizing ratio system. / Este estudo tem como objetivo avaliar o dimensionamento de um sistema fotovoltaico
conectado à rede (SFCR) de acordo com o posicionamento dos módulos que compõem o
gerador quanto ao ângulo de inclinação e ao ângulo azimutal em Goiânia, Goiás. Para isso foi
realizada uma revisão da literatura quanto às principais metodologias de análise do fator de
dimensionamento do inversor (FDI) aplicado a SFCRs. A partir de uma base de dados em
intervalos horários de medições climáticas de Goiânia desenvolveu-se um algoritmo para
busca do FDI ideal para a localidade, considerando o uso de módulos de silício policristalino
(p-Si). Os parâmetros utilizados na análise foram os parâmetros fornecidos pelos fabricantes
dos componentes utilizados no SFCR em instalação da Escola de Engenharia Elétrica,
Mecânica e de Computação (EMC) da Universidade Federal de Goiás (UFG), cuja potência
nominal é de 33,84 kWp. Os métodos de análise do FDI foram comparados e foi considerado
mais adequado neste estudo o método das perdas máximas anuais por limitação de potência
no inversor. A faixa de FDI obtida para uma variação de -90° a +90° no ângulo azimutal e de
0° a 90° no ângulo de inclinação foi da ordem de 0,54 a 0,77. O potencial de aprimoramento
de indicadores financeiros por meio do FDI foi verificado e foi estimada uma potencial
redução acima de 10% do custo da energia produzida comparando o aperfeiçoamento do FDI
com um FDI unitário.
|
148 |
Energia solar fotovoltaica como fonte alternativa de geração de energia elétrica em edificações residenciais / Photovoltaic solar energy as a power generation alternative in residential buildingsRegina Célia Torres 18 October 2012 (has links)
A matriz energética mundial é composta por várias fontes primárias, dentre as quais os combustíveis fósseis, como o petróleo, prevalecem sobre as demais. No entanto, devido ao crescimento populacional e ao desenvolvimento tecnológico e industrial, haverá um conseqüente aumento na demanda de energia e devido à preocupação ambiental, será necessária a busca por outras fontes energéticas. Dentre essas, destaca-se a energia solar fotovoltaica, por possibilitar a geração de forma limpa e descentralizada. O Brasil tem a vantagem de estar localizado na zona inter-tropical, registrando altos índices de irradiação solar durante todo o ano, em comparação com outros países do mundo que já fazem uso desta tecnologia. Neste trabalho, foi estudada a inserção de sistemas fotovoltaicos conectados à rede elétrica pública e integrados em edificações residenciais urbanas. Para tanto, foram dimensionados sistemas para três residências situadas em diferentes regiões brasileiras, e que possuem as mesmas características construtivas e o mesmo consumo médio mensal de energia elétrica. Uma das premissas consideradas foi a autossuficiência energética das edificações apenas utilizando o recurso solar como fonte de geração. As cidades escolhidas para a análise foram Porto União/SC, São Carlos/SP e Petrolina/PE por possuírem diferenças significativas nos níveis de irradiação solar, representando desta forma os extremos encontrados no território brasileiro. A partir do dimensionamento foram estimadas a geração de energia elétrica anual para cada localidade e as curvas de geração foram confrontadas com as curvas de demanda diária média das regiões Sul, Sudeste e Nordeste, representando respectivamente, as três cidades escolhidas. Foram estimados os custos de instalação dos três sistemas, sendo feita ainda uma análise econômica simplificada para a verificação do impacto gerado pela inserção da tecnologia solar fotovoltaica como fonte alternativa na geração de energia elétrica em edificações residenciais urbanas. Para a avaliação econômica foi considerada a adoção do Sistema de Compensação Energética e um Período de Retorno Simples, que é a relação obtida entre o investimento feito inicialmente para a instalação de um sistema fotovoltaico e a economia anual proporcionada por essa instalação. Considerando um período de vida útil de um sistema fotovoltaico como sendo estimado em 25 anos, os resultados demonstraram que todos os sistemas seriam pagos antes desse período. A partir dos dimensionamentos, foi possível concluir ainda que a área requerida para a instalação de sistemas fotovoltaicos em residências é muito pequena e possui elevado potencial de aproveitamento, viabilizando desse modo a sua inserção no ambiente urbano. / The world\'s energy matrix is made up of several primary sources among which fossil fuels, mainly oil, prevail. Nevertheless, given population growth coupled with technological and industrial development, there will consequently be an increase in energy demands and, due to environmental concerns, looking for other energy sources is necessary. Among those, photovoltaic solar energy stands out for providing clean, decentralized energy generation. Brazil has the advantage of being located within the intertropical zone, registering higher levels of solar irradiation throughout the year compared to other countries that already use such technology. In this thesis, we studied the insertion of photovoltaic systems into the public grid and integrated to urban residential buildings. For such, we sized systems for three home environments situated in different Brazilian regions with similar building characteristics and same average monthly consumption. One of the premises considered was the buildings energy self-sufficiency based on solar resources alone. The cities chosen for the experiment were Porto União/SC, São Carlos/SP and Petrolina/PE given their significantly different exposure to solar irradiation, thus representing the extremes found in the Brazilian territory. From the initial sizing up the annual electricity demand for each location was estimated and generation curves were confronted with the daily demand curves from the South, Southeast and Northeast regions representing, respectively, the three chosen cities. Implementation costs were estimated for the three systems along with a simplified economic analysis in order to verify the impact caused by the insertion of photovoltaic solar energy as an alternative source of power generation in urban residential buildings. For the economic evaluation was considered the use of the Compensation System Energy and a Simple Payback Period, which is the ratio between the initial investment for the installation of a photovoltaic system and the annual savings provided by this facility. Considering a life cycle of a photovoltaic system as estimated at 25 years, the results showed that all systems would be paid before that period. From the sizing was still possible to conclude that the area required for the installation of photovoltaic systems in residences is very small and has a high potential for use, thereby enabling their integration into the urban environment
|
149 |
Qualificação profissional e capacitação laboratorial em sistemas fotovoltaicos / Professional and laboratory qualification in photovoltaic systemsAndré Ricardo Mocelin 15 May 2014 (has links)
Este trabalho utiliza a experiência do Laboratório de Sistemas Fotovoltaicos do Instituto de Energia e Ambiente da Universidade de São Paulo (LSF-IEE-USP) para propor meios efetivos para qualificação de recursos humanos, dentro de laboratórios com qualidade reconhecida, com o intuito de aumentar a quantidade de especialistas na área. Para tanto, foi criado um local, na forma de laboratório, denominado Unidade de Capacitação Tecnológica, composto por sistemas fotovoltaicos isolados e conectados à rede e por duas minirredes híbridas de geração de energia (solar, diesel e rede elétrica), com sistemas de monitoramento próprios, que permitem a avaliação de diferentes estratégias de operação de sistemas fotovoltaicos. Tal Unidade foi concebida sob uma perspectiva didática, para possibilitar a apropriação das habilidades técnicas e conhecimentos tecnológicos necessários para: a) atuar nas diversas ocupações demandadas pelo setor (instaladores, projetistas e engenheiros); b) desenvolver pesquisas na área (especializações, mestrados e doutorados); e c) prestar suporte para iniciativas interessadas na aplicação da tecnologia fotovoltaica (ensaios, consultorias e treinamentos). A apresentação da Unidade conta com a descrição dos materiais, ferramentas, instrumentos e procedimentos utilizados para a acreditação dos laboratórios que a compõem, permitindo demonstrar a confiabilidade, credibilidade e universalidade de seus processos, especialmente no que se refere à realização de ensaios de conformidade em equipamentos fotovoltaicos. O trabalho também investiga iniciativas de capacitação que estão sendo realizadas em outras universidades, escolas técnicas e iniciativa privada, para compreender o perfil dos profissionais atuantes no mercado. A ideia é demonstrar o quanto é fundamental a criação de uma forma de certificação ou uma política instrutiva para a capacitação dos profissionais de sistemas fotovoltaicos, de forma a promover as boas práticas e inibir aquelas que comprometam a credibilidade da tecnologia. Esta tese demonstra que laboratórios capacitados, como a Unidade descrita neste trabalho, apresentam os elementos necessários para produção e divulgação de conhecimentos, desenvolvimento de produtos, prestação de serviços e treinamento de profissionais requeridos para a expansão do setor, podendo colaborar para a consolidação da energia fotovoltaica como uma alternativa eficaz e confiável no cenário energético brasileiro. / This work uses the experience of the Photovoltaic Systems Laboratory of the Institute for Energy and Environment of the University of São Paulo (LSF-IEE-USP) to propose effective ways for the qualification of human resources within laboratories with recognized quality, in order to increase the amount of experts. Thus, a site was created in the form of laboratory, named Technology Skills Unit, composed of individual photovoltaic systems and two hybrid power systems (solar, diesel and power grid), with monitoring systems that allows evaluation of different operating of photovoltaic systems. This unit is designed in a didactic perspective to enable the appropriation of technical skills and technological knowledge necessary for: a) act in different occupations demanded by the sector (installers, designers and engineers), b) develop research in the area and c) provide support for initiatives interested in the application of photovoltaic technology. The presentation of the Unit has the description of the materials, tools, instruments and procedures for the accreditation of laboratories that comprise it, allowing demonstrate the reliability, credibility and universality of its processes, especially with regard to the testing of conformity in photovoltaic equipment. This study also investigates training initiatives being undertaken at other universities, technical schools, and private initiative to understand the profile of the professionals working in the market. The idea is to demonstrate how essential is the creation of a form of certification or an instructive policy for the professional of photovoltaic in order to promote good practice and inhibit those that undermine the credibility of technology. This thesis demonstrates that trained laboratory personnel with the structure proposed in this paper and accredited as is described, presents the necessary elements for the dissemination of technical and scientific knowledge required to qualify professionals specializing in photovoltaic applications, and may contribute to the consolidation of photovoltaic solar energy as effective and reliable alternative to the energy scenario that is imposed in Brazil today.
|
150 |
Conversor CC-CC boost entrelaçado aplicado no processamento da energia de arranjo solar fotovoltaicoSobreira Júnior, Pedro de Assis 09 September 2011 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-09-12T19:03:04Z
No. of bitstreams: 1
pedrodeassissobreirajunior.pdf: 1664123 bytes, checksum: ae5400f0030a2d345dee7ce28cd98b69 (MD5) / Approved for entry into archive by Diamantino Mayra (mayra.diamantino@ufjf.edu.br) on 2016-09-13T12:50:57Z (GMT) No. of bitstreams: 1
pedrodeassissobreirajunior.pdf: 1664123 bytes, checksum: ae5400f0030a2d345dee7ce28cd98b69 (MD5) / Made available in DSpace on 2016-09-13T12:50:57Z (GMT). No. of bitstreams: 1
pedrodeassissobreirajunior.pdf: 1664123 bytes, checksum: ae5400f0030a2d345dee7ce28cd98b69 (MD5)
Previous issue date: 2011-09-09 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho apresenta o estudo e avaliação experimental do controle de uma topologia de conversor CC-CC boost entrelaçado aplicado em sistemas de geração solar fotovoltaica. A análise comparativa das duas principais técnicas de rastreamento de máxima potência possibilitou elucidar se o método de controle por tensão ou corrente terminal do painel solar fotovoltaico apresentam diferença significativa na eficiência do processo de conversão de energia solar em eletricidade. A estrutura de conversor elevador de tensão entrelaçado possibilita mitigar o efeito do sombreamento parcial em arranjos fotovoltaicos, reduzir o dimensionamento dos elementos passivos e prover rápida resposta transitória. Resultados de simulação e experimentais usando um Controlador Digital de Sinais comprovam o potencial da estrutura estudada para o condicionamento de energia em arranjos solares fotovoltaicos. / This work presents the study and experimental evaluation of the control of an interleaved boost DC-DC converter topology used in solar photovoltaic generation systems. The comparative analysis of two major techniques for tracking maximum power point allowed to elucidate whether the method of control by terminal photovoltaic voltage or current show significant difference in the efficiency of converting solar energy into electricity. The boost interleaved converter allows mitigating the effect of partial shading on photovoltaic arrays, reducing sizing of passive elements and providing fast transient response. Simulation and experimental results using a Digital Signal Controller demonstrate the potential of the studied structure for power conditioning in photovoltaic solar arrays.
|
Page generated in 0.0433 seconds