• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 81
  • 43
  • 24
  • 20
  • 13
  • 4
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 231
  • 231
  • 94
  • 74
  • 67
  • 38
  • 35
  • 34
  • 33
  • 27
  • 26
  • 22
  • 19
  • 19
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Caractérisation hydro-thermique d’un réacteur industriel : vers un nouveau procédé plus performant / Hydro-thermal characterization of an industrial reactor : towards a more efficient process

Zenner, Alexis 29 May 2018 (has links)
L'hydrodynamique et les transferts thermiques dans des réacteurs types lits fixes font l'objet d'études depuis une soixantaine d'années. Les informations fournies par ces travaux sont importantes pour le dimensionnement des réacteurs industriels. En effet, une étroite relation entre les propriétés de transports et le design du procédé (réacteur et support catalytique) est mise en avant dans l'état de l'art. Mais force est de constater que la complexité des phénomènes entraine des divergences entre les observations et les différentes conclusions faites par les auteurs. Deux pilotes à échelle laboratoire ont été conçus et mis en place au cours de cette thèse. L'un est dédié à l'étude hydrodynamique et l'autre à l'étude thermique. La caractérisation hydro-thermique des réacteurs passe également par une étape de développement de modèles mathématiques associés aux pilotes. Ils représentent les transferts opérant au sein d'une colonne garnie. Ils permettent également d'estimer les paramètres effectifs du milieu poreux. Les quatre grandeurs caractéristiques étudiées dans cette thèse sont les pertes de charges, la dispersion axiale, la conductivité effective globale et le coefficient d'échange thermique à la paroi. Les résultats obtenus à partir des modèles sont comparés aux travaux de la littérature. Ceci permet de valider les méthodes d'estimation développées dans cette thèse. Il est remarqué que les corrélations prédictives de la conductivité effective sont peu adaptées aux morphologies de supports les plus complexes. Nous proposons donc aussi de nouvelles corrélations basées sur nos mesures / Hydrodynamics and heat transfers in packed bed reactors have been studied for about sixty years. The information supplied by this work is important for the design of industrial reactors. Indeed, there is a close relationship between the heat and mass transfers and the design of the process (reactor and catalytic support); this is highlighted in the state of the art. It is clear that the complexity of the phenomena is the cause of divergences between the observations and the conclusions made by the authors. Two laboratory-scale pilots were designed and set up during this PhD thesis. One is dedicated to the hydrodynamic studies and the other to the thermal studies. The hydro-thermal characterization of the reactors includes a step of development of mathematical models associated with the pilots. They represent transfers occurring within the bed of particles. Coupling experimental data with the models allows estimating the effective parameters of the porous medium. The four characteristic quantities studied in this PhD thesis are the pressure drop, the axial dispersion, the overall effective conductivity and the heat transfer coefficient at the wall. The results are compared with the data provided by the open literature. This validates the estimation methods developed during this PhD thesis. It is noticed that the predictive correlations of the effective thermal conductivity are not adapted to the morphologies of the most complex supports. Based on our measurements, new correlations were developed
162

Stockage massif d'électricité sous forme thermique / Large scale Thermal Energy Storage of Electricity

Desrues, Tristan 28 June 2011 (has links)
Les travaux présentés dans cette thèse concernent un nouveau procédé de stockage d'électricité à échelle industrielle, sous forme de stockage de chaleur sensible. La chaleur est stockée dans deux échangeurs gaz-solide de grande taille appelés régénérateurs qui sont reliés à une paire de turbomachines (compresseur et turbine) formant ainsi un cycle thermodynamique. Selon le sens d'écoulement du fluide caloporteur, ce cycle est de type « pompe à chaleur » en stockage ou « moteur thermique » en déstockage. La modélisation complète du procédé a permis de caractériser son comportement dans un cas industriel, et de mettre en évidence les tendances principales du système. Les performances prévues se rapprochent de celles des installations existantes les plus adaptées au stockage massif d'électricité, telles que le stockage hydraulique gravitaire. Une étude CFD a permis l'optimisation d'une géométrie de canal à obstacles destinée à intensifier l'échange thermique dans les régénérateurs et qui sera testée expérimentalement à la suite de cette thèse. Les préparatifs de cette expérience sont abordés et ses objectifs sont explicités. / Les travaux présentés dans cette thèse concernent un nouveau procédé de stockage d'électricité à échelle industrielle, sous forme de stockage de chaleur sensible. La chaleur est stockée dans deux échangeurs gaz-solide de grande taille appelés régénérateurs qui sont reliés à une paire de turbomachines (compresseur et turbine) formant ainsi un cycle thermodynamique. Selon le sens d'écoulement du fluide caloporteur, ce cycle est de type « pompe à chaleur » en stockage ou « moteur thermique » en déstockage. La modélisation complète du procédé a permis de caractériser son comportement dans un cas industriel, et de mettre en évidence les tendances principales du système. Les performances prévues se rapprochent de celles des installations existantes les plus adaptées au stockage massif d'électricité, telles que le stockage hydraulique gravitaire. Une étude CFD a permis l'optimisation d'une géométrie de canal à obstacles destinée à intensifier l'échange thermique dans les régénérateurs et qui sera testée expérimentalement à la suite de cette thèse. Les préparatifs de cette expérience sont abordés et ses objectifs sont explicités.
163

Efeito da perda de carga e calor no po?o injetor no processo de drenagem gravitacional assistido com vapor e solvente

Praxedes, Tayllandya Suelly 06 November 2013 (has links)
Made available in DSpace on 2014-12-17T14:08:55Z (GMT). No. of bitstreams: 1 TayllandyaSP_DISSERT.pdf: 2803522 bytes, checksum: 516959be83003bd573c721b4ad05b984 (MD5) Previous issue date: 2013-11-06 / Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico / Nowadays, most of the hydrocarbon reserves in the world are in the form of heavy oil, ultra - heavy or bitumen. For the extraction and production of this resource is required to implement new technologies. One of the promising processes for the recovery of this oil is the Expanding Solvent Steam Assisted Gravity Drainage (ES-SAGD) which uses two parallel horizontal wells, where the injection well is situated vertically above the production well. The completion of the process occurs upon injection of a hydrocarbon additive at low concentration in conjunction with steam. The steam adds heat to reduce the viscosity of the oil and solvent aids in reducing the interfacial tension between oil/ solvent. The main force acting in this process is the gravitational and the heat transfer takes place by conduction, convection and latent heat of steam. In this study was used the discretized wellbore model, where the well is discretized in the same way that the reservoir and each section of the well treated as a block of grid, with interblock connection with the reservoir. This study aims to analyze the influence of the pressure drop and heat along the injection well in the ES-SAGD process. The model used for the study is a homogeneous reservoir, semi synthetic with characteristics of the Brazilian Northeast and numerical simulations were performed using the STARS thermal simulator from CMG (Computer Modelling Group). The operational parameters analyzed were: percentage of solvent injected, the flow of steam injection, vertical distance between the wells and steam quality. All of them were significant in oil recovery factor positively influencing this. The results showed that, for all cases analyzed, the model considers the pressure drop has cumulative production of oil below its respective model that disregards such loss. This difference is more pronounced the lower the value of the flow of steam injection / Atualmente, a maior parte das reservas de hidrocarbonetos no mundo se encontram na forma de ?leo pesado, ultra-pesado ou betume. Para a extra??o e produ??o desse recurso ? necess?ria a implanta??o de novas tecnologias. Um dos processos promissores para a recupera??o desse ?leo ? a drenagem gravitacional assistida com vapor e solvente (ESSAGD) que utiliza dois po?os horizontais paralelos, onde o injetor ? disposto acima do produtor. A realiza??o do processo se d? mediante a inje??o de um aditivo de hidrocarboneto em baixa concentra??o em conjunto com vapor. O vapor contribui com calor para redu??o da viscosidade do ?leo e o solvente ajuda na miscibilidade, reduzindo a tens?o interfacial entre ?leo/solvente. A principal for?a atuante neste processo ? a gravitacional e a transfer?ncia de calor ocorre por meio da condu??o, convec??o e pelo calor latente do vapor. Neste estudo foi utilizado o modelo discretizado, onde o po?o ? discretizado da mesma forma que o reservat?rio, sendo cada se??o do po?o tratada como um bloco da grade, com conex?o interblocos com o reservat?rio. O presente trabalho tem como objetivo analisar a influ?ncia da perda de carga e calor ao longo do po?o injetor no processo ES-SAGD. O modelo utilizado para estudo trata-se de um reservat?rio homog?neo, semissint?tico com caracter?sticas do Nordeste Brasileiro e as simula??es num?ricas foram realizadas atrav?s do simulador t?rmico STARS da CMG (Computer Modelling Group). Os par?metros operacionais analisados foram: porcentagem de solvente injetado, vaz?o de inje??o de vapor, dist?ncia vertical entre os po?os e qualidade de vapor. Todos eles foram significativos no Fator de Recupera??o de ?leo. Os resultados demonstraram que, para todos os casos analisados, o modelo que considera a perda de carga apresenta produ??o acumulada de ?leo inferior ao seu respectivo modelo que desconsidera tal perda. Essa diferen?a ? mais acentuada quanto menor o valor da vaz?o de inje??o de vapor
164

Estudo da aplicação de conversores catalíticos platina/paládio como auxiliar no processo de controle das emissões gasosas automotivas / Study of application of catalytic converters platin/palladium with auxiliary in the control process of emission gas automotives

Keyll Carlos Ribeiro Martins 30 June 2003 (has links)
Este trabalho de pesquisa visa estudar o processo de formação das emissões gasosas num motor de combustão interna movido à álcool e analisar os fatores que contribuem para o controle dessas emissões em níveis estabelecidos pela legislação. Especial atenção foi dada à aplicação de conversores catalíticos platina/paládio como auxiliar no processo de controle das emissões gasosas automotivas. Foram realizados ensaios dinanométricos de um motor de combustão interna para analisar as emissões e o controle destas, em condições operacionais, em função da razão ar-combustível, ponto de ignição e rotação. O conversor catalítico contribuiu para redução de mais de 80% das emissões gasosas danosas à saúde, quando o motor operava em condições estequiométricas. Observou-se a necessidade de desenvolver o sistema de admissão e descarga do motor para receber o catalisador sem que este cause redução considerável à queda da eficiência volumétrica do motor. / This work of research aim analyzes process of formation of gas emissions in alcohol internal combustion engines and analyses factors that contribute to control those emissions in level established by legislation. Special attention was faced application of catalytic converters platin/palladium with auxiliary in the process of control emissions gas automotives. Assays dynamometric were realized of to analyses emission and control them, in conditions operation ales, in function of air-fuel ratio, point of ignition and rotation the catalytic converters contribute to reduction more of 80% of emissions gas that cause damage health, when observed that necessity of develop system of admission and exhaust of engines to receive catalysts out that provocate reduction considerable decrease of efficiency volumetric of engines.
165

Análise experimental de velocidade crítica em elemento combustível tipo placa plana para reatores nucleares de pesquisa / Experimental analysis of critical velocity in flat plate fuel element for nuclear research reactors

CASTRO, ALFREDO J.A. de 17 November 2017 (has links)
Submitted by Pedro Silva Filho (pfsilva@ipen.br) on 2017-11-17T17:27:31Z No. of bitstreams: 0 / Made available in DSpace on 2017-11-17T17:27:31Z (GMT). No. of bitstreams: 0 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Os elementos de combustível de um reator nuclear de pesquisa tipo MTR (\"Material Testing Reactor\") são, em sua grande maioria, formados por placas de combustível revestidas com alumínio contendo no cerne silicileto de urânio (U3Si2) disperso em matriz de alumínio. Essas placas possuem espessura da ordem de milímetros e comprimentos muito maiores em relação à sua espessura. Elas são dispostas paralelamente no conjunto que forma o elemento combustível, de maneira a formar canais entre elas com poucos milímetros de espessura, por onde escoa o fluido de refrigeração (água leve ou água pesada). Essa configuração, associada à necessidade de um escoamento com altas vazões para garantir o resfriamento das placas em operação, pode gerar problemas de falhas mecânicas das placas de combustível devido às vibrações induzidas pelo escoamento nos canais e, consequentemente, acidentes de proporções graves no caso de velocidade crítica que possa gerar o colapso das placas. Embora não haja ruptura das placas de combustível durante o colapso, as deflexões permanentes excessivas das placas podem causar bloqueio do canal de escoamento no núcleo do reator e levar ao superaquecimento nas placas. Para este trabalho, foram desenvolvidas uma bancada experimental com capacidade para altas vazões volumétricas (Q=100 m3/h) e uma seção de testes que simula um elemento combustível do tipo placa com três canais de resfriamento. A seção de testes foi construída com placas de alumínio e acrílico e foi instrumentada com sensores de deformação, sensores de pressão, um acelerômetro e um tubo de pitot. As dimensões da seção de testes foram baseadas nas dimensões do Elemento Combustível do Reator Multipropósito Brasileiro (RMB), cujo projeto está sendo coordenado pela Comissão Nacional de Energia Nuclear - CNEN. Os experimentos realizados alcançaram o objetivo de chegar à condição de velocidade crítica de Miller com o colapso das placas. A velocidade crítica foi atingida com 14,5 m/s levando a consequente deformação plástica das placas que formam o canal do escoamento. O canal central na entrada da seção de testes apresentou uma abertura de 3 mm em seu centro, causando um grande bloqueio do escoamento nos canais laterais. Este comportamento foi v constatado visualmente durante a desmontagem da seção de testes, ilustrado e discutido na análise de resultados apresentado neste trabalho. O bloqueio dos canais também foi observado por meio de gráficos de queda de pressão e por gráficos das deformações da entrada, centro e saída das placas contra a velocidade média da seção de testes. Observou-se uma queda da resistência hidráulica da seção de testes devido ao aumento da seção transversal de escoamento no canal central e um aumento exponencial das deformações quando da ocorrência da velocidade crítica. Comparativamente, o valor experimental obtido para velocidade crítica na seção de testes foi da ordem de 85% do valor obtido por cálculo com a expressão teórica de Miller. Os experimentos realizados permitiram um melhor entendimento da interação fluido estrutura em elementos de combustível tipo placa como: valores de frequências de vibrações naturais, instabilidade fluido elástica e desenvolvimento de técnicas para a detecção de valores de velocidade crítica. / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP / CNPq:481193/2012-0
166

Estudo teórico e experimental da transferência de calor durante a condensação e perda de pressão no interior de minicanais para os refrigerantes R1234ze(E) e R32 com reduzido GWP / Experimental and theoretical studies on heat transfer condensation and two-phase pressure drop inside minichannels for the low GWP refrigerants R1234ze(E) e R32

Jaqueline Diniz da Silva 28 April 2017 (has links)
Recentemente, observa-se o crescimento do número de trocadores de calor baseados em microcanais devido a necessidade de transferência de elevadas taxas de calor utilizando dispositivos compactos. Tubos de calor, trocadores de calor compactos para equipamentos eletrônicos e controle térmico de satélites, sistemas de condicionamento de ar para automóveis, escritórios e residências são exemplos de aplicações para condensação em canais de diâmetro reduzido. No entanto, na literatura encontra-se reduzido número de estudos experimentais tratando da condensação no interior de canais com diâmetros inferiores a 3 mm, os quais geralmente envolvem refrigerantes com elevado potencial de aquecimento global (GWP). Neste contexto, o presente estudo apresenta uma revisão crítica da literatura envolvendo critérios de transição entre padrões de escoamento, perda de pressão por atrito e coeficiente de transferência de calor durante a condensação no interior de canais convencionais e de micro-escala (minicanais). Levantou-se resultados para o gradiente de pressão por atrito e coeficiente de transferência de calor em aparato experimental localizado na Universidade de Pádua (Università Degli Studi di Padova) para os fluidos refrigerante R1234ze(E) e R32 (GWP de 550 e 6, respectivamente), temperatura de saturação de 40°C, fluxo de calor até 35 kW/m², grau de sub-resfriamento da parede entre 2 e 10 K, velocidade mássicas entre 55 e 275 kg/m²s e título de vapor de 0 a 1. Os dados foram levantados em seção de teste composta por 36 minicanais com diâmetro hidráulico de 1,6 mm e geometria retangular, com o efeito de resfriamento obtido através de água resfriada escoando em contra-corrente ao refrigerante. Os dados experimentais levantados para o gradiente de pressão por atrito e o coeficiente de transferência de calor foram comparados com métodos de previsão da literatura, concluindo que as correlações propostas por Jige, Inoue e Koyama (2016) fornecem as melhores previsões. O comportamento do coeficiente de transferência de calor foi analisado com foco nos mecanismos físicos predominantes durante a condensação. A partir desta análise concluiu-se o predomínio de efeitos de tensão superficial em velocidades mássicas reduzidas e de arrasto em velocidades mássicas elevadas. Este estudo também apresenta uma avaliação comparativa do desempenho dos refrigerantes R1234ze(E) e R32 em relação ao R134a (GWP de 1300) baseada na taxa de transferência de calor por unidade de potência de bombeamento e no potencial de transferência de calor, conforme o critério proposto por Cavallini et al. (2010). Esta análise revelou o desempenho superior para o refrigerante R32 seguido do R134a, com o R1234ze(E) apresentando o pior resultado, independentemente da velocidade mássica. / Recently, micro-scale channels are increasingly being used to combine high heat transfer rates and high degree of compactness. Condensation inside small diameter channels can be found in several applications such as heat pipes, thermal management of electronic equipments, spacecraft thermal control, automotive and residential air conditioning systems, heat pumps and refrigeration systems. However, despite of its importance, few studies concerning condensation inside minichannels (DH < 3 mm) involving low GWP (Global Warming Potential) refrigerants are found in the literature. In this context, initially, this study presents a critical review on the literature involving transition criteria on two-phase flow patterns for micro- and macro-scale conditions, frictional pressure drop and heat transfer coefficient during condensation inside channels. Experimental results for frictional pressure gradient and heat transfer coefficient obtained in apparatus located at the University of Padua (Università Degli Studi di Padova) are carefully analysed. The database includes results for the refrigerants R1234ze(E) and R32 (GWP of 550 and 6, respectively), saturation temperature of 40°C, heat flux up to 35 kW/m², fluid and wall temperature diference up to 10 K, mass velocity in the range of 55 to 275 kg/m²s and vapor quality between 0 and 1. The test section is composed of 36 rectangular minichannels with hydraulic diameter of 1.6 mm. The refrigerant is cooled by water flowing. From a comparison of experimental data for frictional pressure drop and heat transfer coefficient, and prediction methods available in literature, the methods proposed by Jige, Inoue e Koyama (2016) were ranked as the best ones. During the data analyses, focus was put on in order to relate the heat transfer coefficient behavior with the prevailing mecanisms during condensation. Based on this carefull analysis, the predominance of surface tension effects was pointed out under conditions of low mass velocities and condensation inside rectangular minichannels. On the other hand, for high mass velocities shear stress effects prevailed. Also, it has been presented a comparative evaluation of the performance of the refrigerants R1234ze(E), R32 and R134a (GWP of 1300) based on the following criteria: (i) heat transfer rate per unit of power pumping; and (ii) a penalty factor based on the heat transfer potential proposed by Cavallini et al. (2010). According to this evaluation, independently of the mass velocity, the refrigerant R32 was ranked as the one presenting the best performance, followed by R134a ranked as the second best. The refrigerant R1234ze(E) provided the worst performance among them all.
167

Estudo experimental e modelagem do escoamento estratificado ondulado óleo-água / Experimental study and modeling of wavy oil-water stratified pipe flow

Cléber Carvalho Pereira 18 March 2011 (has links)
O escoamento estratificado óleo-água é bastante comum na indústria do petróleo, especialmente em poços direcionas offshore, oleodutos e gasodutos. Entretanto, existem poucos trabalhos na literatura sobre a natureza da estrutura ondulatória observada no escoamento em dutos ascendentes ou descendentes a partir da horizontal. O objetivo deste trabalho foi estudar as propriedades geométricas e cinemáticas da onda interfacial, i.e, forma média, comprimento, amplitude e celeridade, e assim contribuir para a compreensão do papel da onda interfacial na dinâmica do escoamento estratificado. Um software baseado em plataforma Labview® possibilitou a automação para obtenção dos dados das ondas interfaciais extraídas de imagens de vídeos de alta resolução. Além das propriedades das ondas, também se coletaram valores de fração volumétrica in situ e de gradiente de pressão bifásico para cinco ângulos de inclinação (-20°, -10°, 0°, 10° e 20°) em diferentes pares de vazões de óleo e água. Desenvolveu-se um modelo fenomenológico considerando os termos ondulatórios do escoamento para o cálculo da fração volumétrica in situ e do gradiente de pressão bifásico, sendo comparado com modelos disponíveis na literatura e dados experimentais. A concordância do modelo proposto com os dados coletados neste trabalho se mostrou muito boa, o que sugere um avanço em comparação ao existente na literatura. O estudo da equação da onda de perturbação interfacial para o escoamento estratificado óleo-água indicou que a natureza da onda observada é cinemática e não dinâmica; e baseado na equação da celeridade da onda cinemática pode-se confrontar a celeridade experimental com a teórica, revelando boa concordância. / The oil-water stratified flow is quite common in the oil industry, especially in offshore directional wells and pipelines. However, there are few studies on the physics of the wavy structure observed in upward and downward stratified flow. The goal of this work was to study the geometric and kinematic properties of interfacial waves, i.e., the average shape, wavelength, amplitude and celerity. A homemade Labview®-based software enabled the automatic acquisition of data extracted from frames obtained via high resolution video recording. In situ volume fraction and two-phase pressure gradient data for five inclination angles (-20°, -10°, 0°, 10° and 20°) at several pairs of oil and water flow rates were also collected. A phenomenological model that takes into account the wavy structure is proposed to calculate volume fractions and two-phase pressure gradient and it was compared with available models from the literature and experimental data. The good agreement of the proposed model with the data collected in this study is promising and suggests that it may provide better predictions in comparison with models from the literature. The study of the interfacial perturbation wave equation for stratified flow indicates that the observed waves nature is kinematic and not dynamic; and based on the kinematic wave velocity equation we could compare the experimental celerity with the theoretical one, with good agreement.
168

Análise experimental dos efeitos do fluido e da orientação do escoamento no desempenho de dissipadores de calor baseados na ebulição convectiva em microcanais / Experimental evaluation of the effect of the fluid and the footprint orientation on the performance of a heat spreader based on flow boiling inside micro-scale channels

Hugo Leonardo Souza Lara Leão 06 February 2014 (has links)
A pesquisa realizada envolveu a avaliação experimental dos efeitos do fluido e da orientação do escoamento no desempenho de um dissipador de calor baseado na ebulição convectiva em microcanais. Estes dissipadores de calor são usados como uma nova aplicação para a refrigeração dos novos dispositivos eletrônicos que geram altas taxas de calor. Efetuou-se inicialmente uma extensa pesquisa bibliográfica sobre o escoamento monofásico e a ebulição convectiva em microcanais e em multi-microcanais através da qual levantou-se os principais métodos de previsão do coeficiente de transferência de calor e da perda de pressão. Então, utilizando o aparato experimental desenvolvido durante o mestrado de Do Nascimento (2012) avaliou-se a transferência de calor e perda de pressão de um dissipador de calor baseado em multi-microcanais paralelos. O dissipador de calor avaliado possui 50 microcanais retangulares dispostos paralelamente com 15 mm de comprimento, 100 µm de largura, 500 µm de altura e espaçados de 200 µm. Ensaios experimentais foram executados para o R245fa, fluido de baixa pressão utilizado em ciclos frigoríficos de baixa pressão, e R407C, fluido de alta pressão usado para conforto térmico, temperatura de saturação de 25 e 31°C, velocidades mássicas de 400 a 1500 kg/m²s, graus de subresfriamento do líquido de 5, 10 e 15°C, título de vapor máximo de até 0,38, fluxos de calor de até 350 kW/m², e para 3 orientações diferentes do dissipador de calor, horizontal, vertical com os canais alinhados horizontalmente e vertical com escoamento ascendente. Os resultados obtidos foram parametricamente analisados e comparados com métodos da literatura. Coeficientes de transferência de calor médios de até 35 kW/m² °C foram obtidos. Resultados adquiridos para o R245fa e R407C foram inferiores aos levantados por Do Nascimento (2012) para o R134a utilizando o mesmo dissipador. O fluido R407C apresentou frequências e amplitudes de oscilações inferiores aos fluidos R134a e R245fa. Nenhum método para o coeficiente de transferência de calor e perda de pressão proporcionou previsões satisfatórias dos dados experimentais. O modelo Homogêneo com viscosidade da mistura bifásica dada por Cicchitti et al. (1960) apresentou as melhores previsões da perda de pressão, já para o coeficiente de transferência de calor, os métodos de Bertsch et al. (2009) e Liu e Winterton (1991) apresentaram as melhores previsões. O dissipador com sua base posicionada horizontalmente fornece coeficientes de transferência de calor superiores enquanto sua base na vertical e escoamento ascendente verificam-se perdas de pressão inferiores. Imagens do escoamento bifásico foram obtidas com uma câmera de alta velocidade e analisadas. / This study presents an experimental investigation on the effect of the fluid and the footprint orientation on the performance of a heat spreader based on flow boiling inside micro-scale channels. This heat spreader is used in an electronics cooling application with high-power density. Initially an extensive investigation of the literature concerning single-phase and two-phase flow inside a single microchannels and multi-microchannels was performed. In this literature review the leading predictive methods for heat transfer coefficient and pressure drop are described. The experimental study was carried out in the apparatus developed by Do Nascimento (2012). The heat sink evaluated in the present study is comprised of fifty parallel rectangular microchannels with cross-sectional dimensions of 100 µm width and of 500 µm depth, and total length of 15 mm. The fins between consecutive microchannels are 200 µm thick. Experimental tests were performed for R245fa, low-pressure fluid used in low pressure refrigeration cycles, and R407C, high-pressure fluid used for heat comfort, saturation temperature of 25 and 31°C, mass velocities from 400 to 1500 kg/m² s, degrees of subcooling of the liquid of 5, 10 and 15°C, outlet vapor quality up to 0.38, heat fluxes up to 350 kW/m², and for the following footprint heat sink orientations: horizontal, vertical with the microchannels aligned horizontally and vertical with upward flow. The results were parametrically analyzed and compared again the predictive methods from literature. Average heat transfer coefficients up to 35 kW/m² °C were obtained. The results for R134a from Do Nascimento (2012) for the same heat sink presented heat transfer coefficients higher than R245fa and R407C. The fluid R407C presented oscillation of the temperature due to thermal instability effects with lower frequency and amplitude lower than R134a, and R245fa. None predictive method provided satisfactory heat transfer coefficient and pressure drop predictions of the experimental data. The Homogeneous model with the viscosity given by Cicchitti et al. (1960) provided the best pressure drop prediction while the heat transfer coefficient was best predicted by Bertsch et al. (2009) and Liu and Winterton (1991). The horizontal orientation of the footprint provided the highest heat transfer coefficients while the vertical footprint orientation with upward flow the lowest pressure drops. Images of the two-phase flow were obtained with a high-speed camera and analyzed.
169

Theoretical and experimental study on convective boiling inside tubes containing twisted-tape inserts / Estudo teórico e experimental sobre a ebulição convectiva no interior de tubos com fitas retorcidas

Taye Stephen Mogaji 25 March 2014 (has links)
This research comprises an experimental and theoretical study on convective boiling inside tubes containing twisted-tape inserts. The demand for more compact and efficient thermal systems, in which the heat exchangers plays an important role, has led to the development and use of various heat transfer enhancement techniques. Among them twisted-tape insert as a swirl flow device is one of the most used. Twisted-tape inserts have been used for over more than one century ago as a technique of heat transfer enhancement applied to heat exchangers. However, the heat transfer augmentation comes together with pressure drop increment, impacting the pumping power and, consequently, the system efficiency. Moreover, until now it is not clear, the operational conditions under which the heat transfer coefficient augmentation by the use of twisted-tape inserts overcomes pressure drop penalty. In the present study, initially, extensive investigations of the literature concerning convective boiling inside plain tubes with and without twisted-tape inserts were performed. This literature review covers pressure drop, heat transfer coefficient and the leading frictional pressure drop gradient and heat transfer coefficient predictive methods during convective boiling inside tubes with and without twisted-tape inserts. Then, pressure drop and heat transfer coefficient results acquired in the present study were obtained in an experimental apparatus of 12.7 and 15.9 mm ID tubes during flow boiling of R134a for twisted-tape ratios of 3, 4, 9, 14 and tubes without inserts, mass velocities ranging from 75 to 200 kg/m2 s, saturation temperatures of 5 and 15°C and heat fluxes of 5 and 10 kW/m2. The experimental results were parametrically analyzed and compared against the predictive methods from literature. An analysis of the enhancement of the heat transfer coefficient and the pressure drop penalty is presented. Heat transfer coefficient increments up to 45% keeping the same pumping power and pressure drop penalty of about 35% were obtained by using twisted-tape relative to tubes without inserts. Additionally, through comparison of the present study experimental results with the predictive methods from the literature for heat transfer coefficient during two-phase flow inside tube containing twisted-tape inserts, it was verified that non of these methods predict satisfactory well the experimental results. However, a new method was develop for predicting the heat transfer coefficient during flow boiling inside tubes containing twisted-tape inserts based on the experimental results obtained in the present study. The predictive method takes into account the physical picture of the swirl flow phenomenon by including swirl flow effects promoted by the twisted-tape inserts. The proposed method predicts satisfactorily well the data obtained in the present study, predicting 89.1% of the experimental data within an error band of ± 30% and absolute mean deviation of 15.7%. / A presente pesquisa trata-se de um estudo teórico e experimental sobre a ebulição convectiva no interior de tubos com fitas retorcidas. A crescente demanda por sistemas térmicos mais compactos e eficientes, nos quais os trocadores de calor apresentam elevada relevância, tem motivado o desenvolvimento de inúmeras técnicas de intensificação de troca de calor, sendo que a utilização de fitas retorcidas é uma das técnicas mais adotadas. Fitas retorcidas são utilizadas como técnicas de intensificação de troca de calor há mais de um século. Entretanto o incremento da transferência de calor é acompanhado do aumento da perda de pressão, que por sua vez implica em aumento da potência de bombeamento, e consequentemente afeta a eficiência global do sistema. Adicionalmente, até os dias de hoje não há consenso sobre as condições operacionais em que o ganho com o incremento do coeficiente de transferência de calor é superior à perda devido ao aumento da perda de pressão. Neste estudo, inicialmente foi realizada uma extensa revisão da literatura sobre a ebulição convectiva no interior de tubos com e sem fitas retorcidas. Esta revisão aborda aspectos relacionados à perda de pressão e ao coeficiente de transferência de calor, juntamente com os métodos de previsão destes parâmetros. Foram realizados experimentos para determinação experimental de perda de pressão e coeficiente de transferência de calor, em aparato experimental contando com tubos horizontais com diâmetros internos iguais a 12,7 e 15,9 mm, para escoamento bifásico de R134a, razões de retorcimento iguais a 3, 4, 9, 14 e tubo sem fita, velocidades mássicas entre 75 e 200 kg/m²s, temperaturas de saturação iguais a 5 e 15°C, e fluxo de calor iguais a 5 e 10 kW/m². Os resultados experimentais foram analisados e comparados com estimativas segundo métodos disponíveis na literatura. Uma análise do aumento do coeficiente de transferência de calor e da perda de pressão friccional é apresentada. Foram verificados incrementos do coeficiente de transferência de calor de até 45% para a mesma potência de bombeamento, e aumento de perda de pressão de aproximadamente 35% para tubos com fitas retorcidas em relação aos tubos sem fita. Adicionalmente, através da comparação dos resultados experimentais com os métodos de previsão para coeficiente de transferência de calor, foi verificado que nenhuma metodologia apresentava previsões satisfatórias dos resultados. Portanto um novo método para previsão do coeficiente de transferência de calor durante ebulição convectiva no interior de tubos com fitas retorcidas foi desenvolvido com base nos resultados experimentais obtidos durante o presente estudo. O método proposto é função de parâmetros geométricos e do escoamento, e também de parâmetros físicos do escoamento rotacional induzido pela fita. A metodologia desenvolvida apresenta previsões satisfatórias dos resultados experimentais, prevendo 89,1% dos resultados experimentais com erro inferior a ± 30% e erro médio absoluto igual a 15,7%.
170

Análises experimental, teórica e computacional do escoamento dos gases de exaustão no conversor catalítico platina/paládio instalado em um motor de combustão interna a etanol / Experimental, theoretical, and computational analysis of exhaust gases flow in catalytic converter platinum-palladium of internal combustion engine burning ethanol

Keyll Carlos Ribeiro Martins 29 June 2006 (has links)
O trabalho consiste em análises experimental, teórica e computacional do escoamento dos gases de exaustão através de um conversor catalítico platina-paládio, instalado num motor de combustão interna movido a etanol. Foram realizados ensaios dinanométricos no motor para análise das medidas experimentais no sistema de exaustão e para aquisição de valores das propriedades termodinâmicas, de transporte e de concentrações químicas, os quais serviram de dados iniciais para a simulação computacional desenvolvida com a utilização dos softwares CFX e MFIX. Os programas resolvem um conjunto de equações conservativas que permitem a análise da variação da pressão, temperatura, velocidade e composição química dos gases de escape ao longo do suporte monolítico. Além de avaliar a formação e os níveis das emissões provenientes da combustão da mistura ar-combustível. A eficiência catalítica no primeiro suporte do conversor foi de 11% THC, 100% NOx e 20% CO. Foi verificada uma diferença de 1,23% entre a velocidade média experimental e a simulada. Modelos matemáticos foram aplicados no estudo da perda de carga no conversor catalítico e na relação difusão-reação do consumo e formação das espécies químicas. / The thesis describes computational, experimental, and theoretical analysis of the exhaust gases flow through a Pt/Pd catalytic converter installed on internal combustion engine burning ethanol. The obtained values related to energy properties and mass transport in experimental tests is the base of initial values for development of the computational simulation by using CFX and MFIX software. The programs solves a group of conservative equations that allow to analysis of variation such as pressure, temperature, and also, velocity of exhausting gases along the monolithic support, moreover to evaluate the formation of gases and its emission levels on the incoming air-fuel mixture combustion and its respective chemical reactions of oxidation. The catalytic efficiency through the first monolith of the converter were about of 11% THC, 100% NOx e 20% CO. It was verified also a small difference of 1,2 % between the experimental and the simulated average velocity. In addition mathematical models were applied on the study of the load loss in catalytic converter, diffusion-reaction of the consumption and also formation of chemical species.

Page generated in 0.0244 seconds