• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 20
  • Tagged with
  • 20
  • 20
  • 20
  • 18
  • 16
  • 15
  • 15
  • 15
  • 13
  • 10
  • 10
  • 8
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Reconstrução de imagens de ultrassom usando esparsidade: métodos iterativos rápidos / Ultrasonic image reconstruction using sparsity: fast iterative methods

Valente, Solivan Arantes 23 August 2017 (has links)
Este trabalho contribui para a busca de métodos rápidos para reconstrução esparsa em ultrassonografia. O objetivo é alcançado em três etapas: a validação de um modelo discreto de aquisição, uma avaliação comparativa de algoritmos adequados ao problema e uma proposição de aceleração para um dos métodos de melhor desempenho. A estratégia de validação do modelo consiste em reconstruções a partir de dados sintéticos de resultado conhecido e subsequente validação com dados reais, coletados por uma plataforma de pesquisa em ultrassom com um phantom de uso profissional. As reconstruções são realizadas por um conjunto selecionado de algoritmos iterativos de otimização convexa, que têm seus parâmetros, resultados e desempenhos analisados. O trabalho propõe a aceleração do método ADMM (Alternating Direction Method of Multipliers) que está entre os de melhor desempenho em termos de custo computacional, e que pode dobrar sua velocidade inicial de convergência com a modificação proposta. Como a aceleração também pode ser utilizada em outras aplicações do ADMM, a modificação proposta é validada em quatro casos de estudo, sendo dois em ultrassonografia e dois em imageamento por ressonância magnética. / This study contributes to the search for fast iterative methods for ultrasonic sparse image reconstruction. The goal is achieved in three steps: the validation of a discrete acquisition model, a comparative evaluation of algorithms suitable to the problem and an acceleration proposal for one of the best performing methods. The model validation strategy consists of image reconstructions from synthetic data with previously known results, and subsequent validation with real data, collected by an ultrasound research platform with a professional phantom. The reconstructions are performed by a selected set of iterative algorithms of convex optimization, which have their parameters, results and performances analyzed. This study proposes the acceleration of the ADMM (Alternating Direction Method of Multipliers), which is among the best performing methods in terms of computational cost, and which can have its initial convergence speed doubled by the proposed modification. Since the acceleration can also be used in other applications of ADMM, the proposed modification is validated in four cases of study: two in ultrasonography and two in magnetic resonance imaging.
12

Método para reconhecimento de vogais e extração de parâmetros acústicos para analises forenses / Method for recognition of vowels and extraction of acoustic parameters for forensic analysis

Dresch, Andrea Alves Guimarães 14 December 2015 (has links)
Exames de Comparação Forense de Locutores apresentam características complexas, demandando análises demoradas quando realizadas manualmente. Propõe-se um método para reconhecimento automático de vogais com extração de características para análises acústicas, objetivando-se contribuir com uma ferramenta de apoio nesses exames. A proposta baseia-se na medição dos formantes através de LPC (Linear Predictive Coding), seletivamente por detecção da frequência fundamental, taxa de passagem por zero, largura de banda e continuidade, sendo o agrupamento das amostras realizado por meio do método k-means. Experimentos realizados com amostras de três diferentes bases de dados trouxeram resultados promissores, com localização das regiões correspondentes a cinco das vogais do Português Brasileiro, propiciando a visualização do comportamento do trato vocal de um falante, assim como detecção de trechos correspondentes as vogais-alvo. / Forensic speaker comparison exams have complex characteristics, demanding a long time for manual analysis. A method for automatic recognition of vowels, providing feature extraction for acoustic analysis is proposed, aiming to contribute as a support tool in these exams. The proposal is based in formant measurements by LPC (Linear Predictive Coding), selectively by fundamental frequency detection, zero crossing rate, bandwidth and continuity, with the clustering being done by the k-means method. Experiments using samples from three different databases have shown promising results, in which the regions corresponding to five of the Brasilian Portuguese vowels were successfully located, providing visualization of a speaker’s vocal tract behavior, as well as the detection of segments corresponding to target vowels.
13

Detecção e classificação de arritmias em eletrocardiogramas usando transformadas wavelets, máquinas de vetores de suporte e rede Bayesiana

Rodrigues, Luiz Carlos Ferreira 02 March 2012 (has links)
Made available in DSpace on 2016-03-15T19:37:40Z (GMT). No. of bitstreams: 1 Luiz Carlos Ferreira Rodrigues.pdf: 3281430 bytes, checksum: ce62f748aa1e8330c7d6402e06d3d41f (MD5) Previous issue date: 2012-03-02 / The cardiopathies are currently, according the Ministério da Saúde, the second biggest cause of mortality among the Brazilians, behind only the brain vascular diseases. The motivation for the work here presented is the identification and classification of cardiopathies registered in Electrocardiogram exams, ECG, such as premature contractions, branches blocks, tachycardia and other rhythms disturbance. Due its easy application and low cost, the ECG is one of the resources more commonly used by researchers and health professionals in the assessment of cardiac conditions. The computational application developed in this study relies in the application of Wavelets Transforms for the digital signal processing of ECG, in extracting the morphologic characteristics, dynamics and spectral of the cycles of the signal and in the submission of these characteristics to two Support Vector Machines (SVM). The output of these two SVM's are combined as input to a Bayesian Network for the identification and classification of the cardiopathies. The characteristic of each cycle, morphologic and spectral, has it dimensionality reduced by Principal Component Analysis (PCA). The spectral characteristics are extracted by the extractions of the Wavelets Transforms coefficients of the signal, whilst the dynamics characteristics are defined by the interval between the global maxima of each cycle. For development, testings and validations of the application we utilize the MIT-BIH Arrhythmia database, made available by Massachusetts Institute of Technology (MIT). At the end of this work we demonstrate that the application is able to recognize and classify 8 types of heart beats in ECG records, with an medium accuracy above 95,0%. / As cardiopatias são atualmente, segundo o Ministério da Saúde, a segunda maior causa de mortalidade entre brasileiros, ficando atrás apenas das doenças cerebrovasculares. A motivação do trabalho aqui apresentado é a identificação e classificação de cardiopatias registradas em exames de Eletrocardiograma, o ECG, tais como contrações prematuras, bloqueio de ramos, taquicardias e outros distúrbios de ritmo. Devido a sua fácil aplicação e baixo custo, o ECG é um dos recursos mais largamente utilizados por pesquisadores e profissionais da saúde na avaliação da saúde do coração. A aplicação computacional desenvolvida neste estudo concentra-se no uso de Transformadas Wavelets para o processamento digital dos sinais de ECG, na extração das características morfológicas, dinâmicas e espectrais de ciclos do sinal e na submissão dessas características a duas Máquinas de Vetores de Suporte (SVM). Os resultados das SVM's são combinadas em uma Rede Bayesiana para a identificação e classificação das cardiopatias. As características morfológicas de cada ciclo do sinal são extraídas através de Análise de Componentes Principais (PCA), as características espectrais são extraídas através da decomposição do sinal em coeficientes de Transformadas Wavelets enquanto as características dinâmicas são definidas pelos intervalos entre o máximo global de cada ciclo. Para desenvolvimento, testes e validação da aplicação foi utilizado o Banco de Arritmias MIT-BIH, disponibilizado pelo Massachusetts Institute of Technology (MIT). Neste trabalho demonstramos que a aplicação desenvolvida é capaz de reconhecer e classificar 8 tipos de batimentos cardíacos em registros de ECG, com uma acurácia média total de classificação superior a 95,0%.
14

Aplicação da ultrassonografia portátil no âmbito da clínica médica / Use of portable ultrasound in internal medicine

Belo, Clayton Moura 13 April 2018 (has links)
A pesquisa buscou avaliar se a ultrassonografia portátil, durante consulta clínica em uma unidade básica de saúde pública do Sistema Único de Saúde brasileiro, foi capaz de fornecer informações adicionais confiáveis para a tomada de decisões terapêuticas e diminuir o tempo de espera para uma eventual avaliação especializada, por meio da comparação entre os achados obtidos na ultrassonografia portátil e na ultrassonografia convencional. A ultrassonografia é o segundo método de avaliação por imagem mais utilizado na prática médica, após o Raio-X. Não emite radiações ionizantes e seu efeito sobre os tecidos biológicos é seguro, desde que em nível de intensidade acústica mínima para obtenção dos resultados desejados. Este trabalho surgiu da observação de quão prolongado é o tempo de espera por exames de ultrassom a que estão sujeitos os pacientes da saúde pública brasileira, chegando até dois anos em alguns casos, contrariando protocolos de recomendação e podendo comprometer a saúde do paciente. Avaliou-se custo-efetividade da tecnologia, suas principais limitações, a necessidade de criação de protocolos para sua utilização e os subsídios fornecidos para a tomada de decisões pelo médico clínico. A tecnologia foi aplicada em exames nas áreas de medicina interna, sistema musculoesquelético e cardiologia. Empregou aparelho de ultrassom portátil aprovado pela Anvisa, modelo Vscan™ Dualprobe. Conforme protocolos do Instituto Americano de Ultrassom em Medicina (AIUM), os sujeitos da pesquisa foram submetidos a exame com aparelho portátil, durante o momento da consulta com o pesquisador, após anamnese e exame físico. Posteriormente, foram submetidos a exame empregando aparelho convencional, com médico possuindo titulação em ultrassonografia. As imagens e os achados foram comparados entre os exames e se calculou um índice de confiabilidade Kappa global nas três áreas estudadas de 91,12%, embora o índice para a área cardíaca tenha sido de 76,92%, o que demonstra a limitação do uso do ultrassom portátil para a área. A pesquisa demonstrou que o emprego da ultrassonografia portátil pode vir a ser um importante aliado do médico clínico, permitindo melhoria da qualidade da saúde prestada aos pacientes do Sistema Único de Saúde brasileiro. / The research aimed to evaluate whether portable ultrasonography, during clinical consultation in a basic public health unit of the Brazilian Unified Health System, was able to provide reliable additional information for therapeutic decision-making and to reduce the waiting time for a specialized evaluation, by means of the comparison between the findings obtained in portable ultrasonography and conventional ultrasonography. Ultrasonography is the second method of image evaluation more used in medical practice after the X-ray. It does not emit ionizing radiation and its effect on biological tissues is safe, provided that at minimum acoustic intensity level to obtain the desired results. This study was based on the observation of the length of time the patient waits for the ultrasound exams to which Brazilian public health patients are subjected, up to two years in some cases, contrary to recommendation protocols and potentially compromising patient´s health. It evaluated the cost-effectiveness of the technology, its main limitations, the need to create protocols for its use and the subsidies provided for the decision-making by the clinician. The technology was applied in examinations in the areas of internal medicine, musculoskeletal system and cardiology. It was used a portable ultrasound device approved by Anvisa, model Vscan™ Dualprobe. According to protocols of the American Institute of Ultrasound in Medicine (AIUM), the subjects were examined with a portable device, during the moment of the consultation with the researcher, after anamnesis and physical examination. Subsequently, they were submitted to an examination using a conventional device, with a doctor having ultrasound titration. The images and findings were compared between the exams and a global Kappa reliability index was calculated in the three studied areas of 91.12%, although the index for the cardiac area was 76.92%, which demonstrates the limitation of the use of portable ultrasound for the area. The research demonstrated that the use of portable ultrasonography can be an important ally of the clinician, allowing an improvement in the quality of health provided to patients of the Brazilian Unified Health System.
15

Uso da análise de discriminante linear em conjunto com a transformada wavelet discreta no reconhecimento de espículas / The linear discriminant analysis usage combined with the discrete wavelet transform in spike detection

Pacola, Edras Reily 18 December 2015 (has links)
CAPES / Pesquisadores têm concentrado esforços, nos últimos 20 anos, aplicando a transformada wavelet no processamento, filtragem, reconhecimento de padrões e na classificação de sinais biomédicos, especificamente em sinais de eletroencefalografia (EEG) contendo eventos característicos da epilepsia, as espículas. Várias famílias de wavelets-mães foram utilizadas, mas sem um consenso sobre qual wavelet-mãe é a mais adequada para essa finalidade. Os sinais utilizados apresentam uma gama muito grande de eventos e não possuem características padronizadas. A literatura relata sinais de EEG amostrados entre 100 a 600 Hz, com espículas variando de 20 a 200 ms. Nesse estudo foram utilizadas 98 wavelets. Os sinais de EEG foram amostrados de 200 a 1 kHz. Um neurologista marcou um conjunto de 494 espículas e um conjunto de 1500 eventos não-espícula. Esse estudo inicia avaliando a quantidade de decomposições wavelets necessárias para a detecção de espículas, seguido pela análise detalhada do uso combinado de wavelets-mães de uma mesma família e entre famílias. Na sequência é analisada a influência de descritores e o uso combinado na detecção de espículas. A análise dos resultados desses estudos indica que é mais adequado utilizar um conjunto de wavelets-mães, com vários níveis de decomposição e com vários descritores, ao invés de utilizar uma única wavelet-mãe ou um descritor específico para a detecção de espículas. A seleção desse conjunto de wavelets, de níveis de decomposição e de descritores permite obter níveis de detecção elevados conforme a carga computacional que se deseje ou a plataforma computacional disponível para a implementação. Como resultado, esse estudo atingiu níveis de desempenho entre 0,9936 a 0,9999, dependendo da carga computacional. Outras contribuições desse estudo referem-se à análise dos métodos de extensão de borda na detecção de espículas; e a análise da taxa de amostragem de sinais de EEG no desempenho do classificador de espículas, ambos com resultados significativos. São também apresentadas como contribuições: uma nova arquitetura de detecção de espículas, fazendo uso da análise de discriminante linear; e a apresentação de um novo descritor, energia centrada, baseado na resposta dos coeficientes das sub-bandas de decomposição da transformada wavelet, capaz de melhorar a discriminação de eventos espícula e não-espícula. / Researchers have concentrated efforts in the past 20 years, by applying the wavelet transform in processing, filtering, pattern recognition and classification of biomedical signals, in particular signals of electroencephalogram (EEG) containing events characteristic of epilepsy, the spike. Several families of mother-wavelets were used, but there are no consensus about which mother-wavelet is the most adequate for this purpose. The signals used have a wide range of events. The literature reports EEG signals sampled from 100 to 600 Hz with spikes ranging from 20 to 200 ms. In this study we used 98 wavelets. The EEG signals were sampled from 200 Hz up to 1 kHz. A neurologist has scored a set of 494 spikes and a set 1500 non-spike events. This study starts evaluating the amount of wavelet decompositions required for the detection of spikes, followed by detailed analysis of the combined use of mother-wavelets of the same family and among families. Following is analyzed the influence of descriptors and the combined use of them in spike detection. The results of these studies indicate that it is more appropriate to use a set of mother-wavelets, with many levels of decomposition and with various descriptors, instead of using a single mother-wavelet or a specific descriptor for the detection of spikes. The selection of this set of wavelets, decomposition level and descriptors allows to obtain high levels of detection according to the computational load desired or computing platform available for implementation. This study reached performance levels between 0.9936 to 0.9999, depending on the computational load. Other contributions of this study refer to the analysis of the border extension methods for spike detection; and the influences of the EEG signal sampling rate in the classifier performance, each one with significant results. Also shown are: a new spike detection architecture by making use of linear discriminant analysis; and the presentation of a new descriptor, the centred energy, based on the response of the coefficients of decomposition levels of the wavelet transform, able to improve the discrimination of spike and non-spike events.
16

Análise térmica, eletromiográfica e mecanomiográfica do músculo reto femoral durante o movimento de pedalada / Thermographic, electromyographic and mechanomyographic analysis of rectus femoris muscle during cycling movement

Gelain, Manuela Cristine 30 October 2016 (has links)
CAPES / Desde a década de 80, a obesidade mundial aumentou cerca de 36%. O cicloergômetro é um recurso para combater a obesidade e também pode ser utilizado como instrumento para manter, reabilitar e avaliar o condicionamento físico. Pedalar promove uma série de benefícios ao organismo como a melhora do condicionamento cardiorrespiratório, do sistema cardiovascular e musculoesquelético, das conexões neurais e da autoestima. A termografia é um recurso utilizado para medir a temperatura emitida pela superfície da pele. A eletromiografia (EMG) e a mecanomiografia (MMG) quantificam e qualificam a contração muscular. O objetivo desta pesquisa é investigar a viabilidade da análise térmica superficial da pele na identificação das alterações metabólicas e vasculares geradas pela contração muscular durante a pedalada, em indivíduos hígidos, por meio da correlação com os sinais eletromiográficos e mecanomiográficos. Onze voluntários do sexo masculino foram separados em dois grupos: sedentários (GS) e dos ativos fisicamente (GA). Eles participaram do protocolo de pedalada com acréscimo de carga até a fadiga muscular do músculo reto femoral. Dois testes (1 e 2), com intervalo de 1h entre ambos, foram realizados. A coleta dos dados antropométricos, cardíacos, térmicos e dos sinais neuromusculares resultou em tabelas exportadas ao software IBM SPSS Statistics para análise da distribuição normal, percentagens, testes de Wilcoxon, Mann-Whitney e correlação da temperatura com os sinais neuromusculares pelo teste de Spearman. As medianas antropométricas dos participantes mostram para o GS a idade de 33±4,5 anos, massa de 82±12 kg, altura de 1,85±0,09 m, IMC de 23,95±2,65 kg/m2, adipometria da coxa de 11,73±4,98 mm e perimetria de 0,55±0,04 cm. Já para o GA, a idade de 28±12 anos, massa de 66,5±8,58 kg, altura de 1,76±0,04 m, IMC de 21,75±2,78 kg/m2 , adipometria da coxa de 10±2,09 mm e perimetria de 0,57±0,02 cm. A frequência cardíaca diminuiu 25% do primeiro para o segundo teste, assim como a pressão arterial, sistólica e diastólica, em cerca de 3 e 15%, respectivamente, no GS. A temperatura diminuiu de 1 a 3 °C em ambos os grupos; entretanto, o teste de Wilcoxon comprovou o resultado significativo apenas para o GS no primeiro teste, com p= 0,018, e no segundo, com p=0,043. Houve aumento da amplitude dos sinais da MMG e EMG, entretanto, os testes de Wilcoxon e Mann-Whitney não apresentaram p-valor significativo. Na correlação da temperatura com a contração muscular, por meio do teste de Spearman, somente o GA apresentou um p-valor significativo e forte na MMG (p=0,01 e r=1,000) e na EMG (p=0,01 e r= -1,000). Com esses achados, concluiu-se que a variação térmica se comporta de modo inversamente proporcional à variação de amplitude dos sinais de EMG e MMG e a temperatura representa um parâmetro viável para análise das alterações metabólicas e vasculares geradas pela contração durante as atividades aeróbicas com acréscimo de carga até a exaustão. / From the 80s on, global obesity increased around 36%. Cycle-ergometer is a resource to oppose obesity and it is also used as a tool to maintain, rehabilitate and evaluate physical conditioning. Cycling promotes a number of benefits to the organism as the improvement of cardiorespiratory condition, cardiovascular and musculoskeletal system, neural connections and self-esteem. Thermography is a resource used to measure body skin temperature. Electromyography (EMG) and mechanomyography (MMG) allows quantifying and qualifying muscle contraction. The goal of this research is to investigate the feasibility of surface skin thermal analysis in the identification of metabolic and vascular disorders created by muscle contraction during cycling in healthy individuals, through correlation with electromyographical and mechanomiographical signals. Eleven male volunteers were separate on two groups: sedentary (GS) and physically active (GA). Both participated on cycling protocol with load increase until muscular fatigue of the rectus femoris occurs. There were two tests (1 and 2) with 1h interval in between. After collection of anthropometric data, cardiac, thermal and neuromuscular signals, tables were compiled and their values exported to IBM's SPSS Statistics in order to check the normal distribution, percentages, Wilcoxon’s and Mann-Whitney’s test and the correlation of temperature with neuromuscular signals using the Spearman's test. The median anthropometric values of the GS showed average age of 33±4,5 years, weight of 82±12 kg, height of 1,85±0,09 m, BMI of 23,95±2,65 kg/m2, measurement of thigh’s skinfold thickness of 11,73±4,98 mm and perimeter of 0,55±0,04 cm. The average values for GA were: age of 28±12 years, weight of 66,5±8,58 kg, height of 1,76±0,04 m, BMI of 21,75±2,78 kg/m2, measurement of thigh’s skinfold thickness of 10±2,09 mm and perimeter of 0,57±0,02 cm. The heart rate decreased 25% from de first to second test, likewise systolic and diastolic arterial pressure around 3% and 15%, respectively, for GS. Temperature decreased from 1 to 3 °C in both groups, however, Wilcoxon’s test proved a significant result only to GS first test p=0,018 and second test p=0,043. The amplitude of MMG and EMG signal increased, however Wilcoxon’s and MannWhitney’s tests did not show a significant p-value. Concerning temperature correlation to muscle contraction by Spearman’s test, only GA showed a significant p-value and strong correlation for MMG (p=0,01 and r=1,000) and EMG (p=0,01 e r= -1000) signals. From these findings, it was concluded that thermal variation behaviors inversely proportional to EMG and MMG amplitude variation, and temperature represents a feasible parameter to analyze the metabolic and vascular disorders created by muscle contraction during aerobic activities with load increase until exhaustion.
17

Avaliação de uma análise automatizada para determinação de atividade enzimática / Evaluation of new method for automatized analysis to determine the enzimatic activity

Estrela, Mariely Cordeiro 31 March 2017 (has links)
O Instituto de Biologia Molecular do Paraná (IBMP) atua na produção de insumos para detecção de doenças. Em parceria com Bio-Manguinhos (Fiocruz) é atualmente responsável pelo fornecimento do módulo de amplificação do KIT NAT Brasileiro para o diagnóstico molecular de HIV (AIDS), HCV (Hepatite C) e HBV (Hepatite B), entre outros produtos para diagnóstico in vitro. O teste molecular consiste basicamente, na amplificação do material genético do vírus (DNA ou RNA) através da técnica de PCR (reação em cadeia pela polimerase) em tempo real, que possibilita a detecção do agente patógeno a partir de pequenas quantidades de ácido nucleico presente na amostra. A reação de PCR ocorre pela atividade da Taq DNA Polimerase, uma enzima termostável amplamente utilizada para replicação seletiva de fragmentos de DNA. Esta enzima foi isolada a partir de uma bactéria termofílica, denominada Thermus aquaticus e é produzida pelo IBMP, sendo considerada um insumo de alta criticidade. Uma das etapas de controle do processo produtivo dessa enzima é a avaliação do extrato bruto enzimático e a determinação da atividade da enzima purificada. O método de quantificação consiste em avaliar a atividade enzimática através da metodologia de PCR convencional, seguida por uma análise do perfil eletroforético das amostras em gel de agarose. No entanto, a metodologia empregada atualmente apresenta uma grande subjetividade, visto que a interpretação dos resultados pode sofrer variações quando analisados por diferentes operadores. O objetivo do presente trabalho é avaliar a implementação de uma análise automatizada dos resultados através do processamento digital de imagens, que além de facilitar sobremaneira as rotinas laboratoriais, pode ser a chave para resultados com maior grau de precisão e repetibilidade, eliminando assim o viés subjetivo do analista. A nova metodologia de análise implica em menor interferência do analista na interpretação dos resultados. O método proposto foi testado em um conjunto de imagens e os resultados obtidos foram comparados com os valores da análise manual atualmente utilizada. Os resultados foram considerados promissores, pois a análise automatizada, além de reduzir significativamente o tempo de análise, possibilita uma padronização dos resultados. / The Molecular Biology Institute of Paraná (IBMP) acts in the production of inputs for detection of diseases. In partnership with Bio-Manguinhos (Fiocruz), it is currently responsible for manufacturing the amplification module of the Brazilian NAT KIT for HIV (AIDS), HCV (Hepatitis C) and HBV (Hepatitis B), besides other products for molecular diagnostics. The molecular test basically consists of amplifying the genetic material of the virus (DNA or RNA) through the real-time PCR (polymerase chain reaction) technique, which enables detection of the pathogen from small amounts of nucleic acid present in the sample. The PCR reaction occurs by the activity of Taq DNA Polymerase, a thermostable enzyme widely used for selective replication of DNA fragments. This enzyme was isolated from a thermophilic bacterium, called Thermus aquaticus and is produced by the IBMP, being considered an input of high criticality. One of the steps in controlling the production process of this enzyme is the evaluation of the enzymatic extract and the determination of the activity of the purified enzyme. The quantification method consists in evaluating the enzymatic activity through the conventional PCR methodology, followed by an analysis of the electrophoretic profile of the agarose gel samples. However, the methodology currently used presents a great subjectivity, since the interpretation of results can suffer variations when analyzed by different operators. The objective of the present work is to evaluate the implementation of an automated analysis of the results through digital image processing, which in addition to facilitating the laboratory routines, can be the key to results with a greater degree of precision and repeatability, thus eliminating the subjective bias of the analyst. The new methodology of analysis implies less interference of the analyst in the interpretation of the results. The proposed method was tested in a set of images and the obtained results were compared with the values of the manual analysis currently used. The results were considered promising because the automated analysis, besides significantly reducing the analysis time, allows a standardization of the results.
18

Uso da análise de discriminante linear em conjunto com a transformada wavelet discreta no reconhecimento de espículas / The linear discriminant analysis usage combined with the discrete wavelet transform in spike detection

Pacola, Edras Reily 18 December 2015 (has links)
CAPES / Pesquisadores têm concentrado esforços, nos últimos 20 anos, aplicando a transformada wavelet no processamento, filtragem, reconhecimento de padrões e na classificação de sinais biomédicos, especificamente em sinais de eletroencefalografia (EEG) contendo eventos característicos da epilepsia, as espículas. Várias famílias de wavelets-mães foram utilizadas, mas sem um consenso sobre qual wavelet-mãe é a mais adequada para essa finalidade. Os sinais utilizados apresentam uma gama muito grande de eventos e não possuem características padronizadas. A literatura relata sinais de EEG amostrados entre 100 a 600 Hz, com espículas variando de 20 a 200 ms. Nesse estudo foram utilizadas 98 wavelets. Os sinais de EEG foram amostrados de 200 a 1 kHz. Um neurologista marcou um conjunto de 494 espículas e um conjunto de 1500 eventos não-espícula. Esse estudo inicia avaliando a quantidade de decomposições wavelets necessárias para a detecção de espículas, seguido pela análise detalhada do uso combinado de wavelets-mães de uma mesma família e entre famílias. Na sequência é analisada a influência de descritores e o uso combinado na detecção de espículas. A análise dos resultados desses estudos indica que é mais adequado utilizar um conjunto de wavelets-mães, com vários níveis de decomposição e com vários descritores, ao invés de utilizar uma única wavelet-mãe ou um descritor específico para a detecção de espículas. A seleção desse conjunto de wavelets, de níveis de decomposição e de descritores permite obter níveis de detecção elevados conforme a carga computacional que se deseje ou a plataforma computacional disponível para a implementação. Como resultado, esse estudo atingiu níveis de desempenho entre 0,9936 a 0,9999, dependendo da carga computacional. Outras contribuições desse estudo referem-se à análise dos métodos de extensão de borda na detecção de espículas; e a análise da taxa de amostragem de sinais de EEG no desempenho do classificador de espículas, ambos com resultados significativos. São também apresentadas como contribuições: uma nova arquitetura de detecção de espículas, fazendo uso da análise de discriminante linear; e a apresentação de um novo descritor, energia centrada, baseado na resposta dos coeficientes das sub-bandas de decomposição da transformada wavelet, capaz de melhorar a discriminação de eventos espícula e não-espícula. / Researchers have concentrated efforts in the past 20 years, by applying the wavelet transform in processing, filtering, pattern recognition and classification of biomedical signals, in particular signals of electroencephalogram (EEG) containing events characteristic of epilepsy, the spike. Several families of mother-wavelets were used, but there are no consensus about which mother-wavelet is the most adequate for this purpose. The signals used have a wide range of events. The literature reports EEG signals sampled from 100 to 600 Hz with spikes ranging from 20 to 200 ms. In this study we used 98 wavelets. The EEG signals were sampled from 200 Hz up to 1 kHz. A neurologist has scored a set of 494 spikes and a set 1500 non-spike events. This study starts evaluating the amount of wavelet decompositions required for the detection of spikes, followed by detailed analysis of the combined use of mother-wavelets of the same family and among families. Following is analyzed the influence of descriptors and the combined use of them in spike detection. The results of these studies indicate that it is more appropriate to use a set of mother-wavelets, with many levels of decomposition and with various descriptors, instead of using a single mother-wavelet or a specific descriptor for the detection of spikes. The selection of this set of wavelets, decomposition level and descriptors allows to obtain high levels of detection according to the computational load desired or computing platform available for implementation. This study reached performance levels between 0.9936 to 0.9999, depending on the computational load. Other contributions of this study refer to the analysis of the border extension methods for spike detection; and the influences of the EEG signal sampling rate in the classifier performance, each one with significant results. Also shown are: a new spike detection architecture by making use of linear discriminant analysis; and the presentation of a new descriptor, the centred energy, based on the response of the coefficients of decomposition levels of the wavelet transform, able to improve the discrimination of spike and non-spike events.
19

Análise térmica, eletromiográfica e mecanomiográfica do músculo reto femoral durante o movimento de pedalada / Thermographic, electromyographic and mechanomyographic analysis of rectus femoris muscle during cycling movement

Gelain, Manuela Cristine 30 October 2016 (has links)
CAPES / Desde a década de 80, a obesidade mundial aumentou cerca de 36%. O cicloergômetro é um recurso para combater a obesidade e também pode ser utilizado como instrumento para manter, reabilitar e avaliar o condicionamento físico. Pedalar promove uma série de benefícios ao organismo como a melhora do condicionamento cardiorrespiratório, do sistema cardiovascular e musculoesquelético, das conexões neurais e da autoestima. A termografia é um recurso utilizado para medir a temperatura emitida pela superfície da pele. A eletromiografia (EMG) e a mecanomiografia (MMG) quantificam e qualificam a contração muscular. O objetivo desta pesquisa é investigar a viabilidade da análise térmica superficial da pele na identificação das alterações metabólicas e vasculares geradas pela contração muscular durante a pedalada, em indivíduos hígidos, por meio da correlação com os sinais eletromiográficos e mecanomiográficos. Onze voluntários do sexo masculino foram separados em dois grupos: sedentários (GS) e dos ativos fisicamente (GA). Eles participaram do protocolo de pedalada com acréscimo de carga até a fadiga muscular do músculo reto femoral. Dois testes (1 e 2), com intervalo de 1h entre ambos, foram realizados. A coleta dos dados antropométricos, cardíacos, térmicos e dos sinais neuromusculares resultou em tabelas exportadas ao software IBM SPSS Statistics para análise da distribuição normal, percentagens, testes de Wilcoxon, Mann-Whitney e correlação da temperatura com os sinais neuromusculares pelo teste de Spearman. As medianas antropométricas dos participantes mostram para o GS a idade de 33±4,5 anos, massa de 82±12 kg, altura de 1,85±0,09 m, IMC de 23,95±2,65 kg/m2, adipometria da coxa de 11,73±4,98 mm e perimetria de 0,55±0,04 cm. Já para o GA, a idade de 28±12 anos, massa de 66,5±8,58 kg, altura de 1,76±0,04 m, IMC de 21,75±2,78 kg/m2 , adipometria da coxa de 10±2,09 mm e perimetria de 0,57±0,02 cm. A frequência cardíaca diminuiu 25% do primeiro para o segundo teste, assim como a pressão arterial, sistólica e diastólica, em cerca de 3 e 15%, respectivamente, no GS. A temperatura diminuiu de 1 a 3 °C em ambos os grupos; entretanto, o teste de Wilcoxon comprovou o resultado significativo apenas para o GS no primeiro teste, com p= 0,018, e no segundo, com p=0,043. Houve aumento da amplitude dos sinais da MMG e EMG, entretanto, os testes de Wilcoxon e Mann-Whitney não apresentaram p-valor significativo. Na correlação da temperatura com a contração muscular, por meio do teste de Spearman, somente o GA apresentou um p-valor significativo e forte na MMG (p=0,01 e r=1,000) e na EMG (p=0,01 e r= -1,000). Com esses achados, concluiu-se que a variação térmica se comporta de modo inversamente proporcional à variação de amplitude dos sinais de EMG e MMG e a temperatura representa um parâmetro viável para análise das alterações metabólicas e vasculares geradas pela contração durante as atividades aeróbicas com acréscimo de carga até a exaustão. / From the 80s on, global obesity increased around 36%. Cycle-ergometer is a resource to oppose obesity and it is also used as a tool to maintain, rehabilitate and evaluate physical conditioning. Cycling promotes a number of benefits to the organism as the improvement of cardiorespiratory condition, cardiovascular and musculoskeletal system, neural connections and self-esteem. Thermography is a resource used to measure body skin temperature. Electromyography (EMG) and mechanomyography (MMG) allows quantifying and qualifying muscle contraction. The goal of this research is to investigate the feasibility of surface skin thermal analysis in the identification of metabolic and vascular disorders created by muscle contraction during cycling in healthy individuals, through correlation with electromyographical and mechanomiographical signals. Eleven male volunteers were separate on two groups: sedentary (GS) and physically active (GA). Both participated on cycling protocol with load increase until muscular fatigue of the rectus femoris occurs. There were two tests (1 and 2) with 1h interval in between. After collection of anthropometric data, cardiac, thermal and neuromuscular signals, tables were compiled and their values exported to IBM's SPSS Statistics in order to check the normal distribution, percentages, Wilcoxon’s and Mann-Whitney’s test and the correlation of temperature with neuromuscular signals using the Spearman's test. The median anthropometric values of the GS showed average age of 33±4,5 years, weight of 82±12 kg, height of 1,85±0,09 m, BMI of 23,95±2,65 kg/m2, measurement of thigh’s skinfold thickness of 11,73±4,98 mm and perimeter of 0,55±0,04 cm. The average values for GA were: age of 28±12 years, weight of 66,5±8,58 kg, height of 1,76±0,04 m, BMI of 21,75±2,78 kg/m2, measurement of thigh’s skinfold thickness of 10±2,09 mm and perimeter of 0,57±0,02 cm. The heart rate decreased 25% from de first to second test, likewise systolic and diastolic arterial pressure around 3% and 15%, respectively, for GS. Temperature decreased from 1 to 3 °C in both groups, however, Wilcoxon’s test proved a significant result only to GS first test p=0,018 and second test p=0,043. The amplitude of MMG and EMG signal increased, however Wilcoxon’s and MannWhitney’s tests did not show a significant p-value. Concerning temperature correlation to muscle contraction by Spearman’s test, only GA showed a significant p-value and strong correlation for MMG (p=0,01 and r=1,000) and EMG (p=0,01 e r= -1000) signals. From these findings, it was concluded that thermal variation behaviors inversely proportional to EMG and MMG amplitude variation, and temperature represents a feasible parameter to analyze the metabolic and vascular disorders created by muscle contraction during aerobic activities with load increase until exhaustion.
20

Avaliação de uma análise automatizada para determinação de atividade enzimática / Evaluation of new method for automatized analysis to determine the enzimatic activity

Estrela, Mariely Cordeiro 31 March 2017 (has links)
O Instituto de Biologia Molecular do Paraná (IBMP) atua na produção de insumos para detecção de doenças. Em parceria com Bio-Manguinhos (Fiocruz) é atualmente responsável pelo fornecimento do módulo de amplificação do KIT NAT Brasileiro para o diagnóstico molecular de HIV (AIDS), HCV (Hepatite C) e HBV (Hepatite B), entre outros produtos para diagnóstico in vitro. O teste molecular consiste basicamente, na amplificação do material genético do vírus (DNA ou RNA) através da técnica de PCR (reação em cadeia pela polimerase) em tempo real, que possibilita a detecção do agente patógeno a partir de pequenas quantidades de ácido nucleico presente na amostra. A reação de PCR ocorre pela atividade da Taq DNA Polimerase, uma enzima termostável amplamente utilizada para replicação seletiva de fragmentos de DNA. Esta enzima foi isolada a partir de uma bactéria termofílica, denominada Thermus aquaticus e é produzida pelo IBMP, sendo considerada um insumo de alta criticidade. Uma das etapas de controle do processo produtivo dessa enzima é a avaliação do extrato bruto enzimático e a determinação da atividade da enzima purificada. O método de quantificação consiste em avaliar a atividade enzimática através da metodologia de PCR convencional, seguida por uma análise do perfil eletroforético das amostras em gel de agarose. No entanto, a metodologia empregada atualmente apresenta uma grande subjetividade, visto que a interpretação dos resultados pode sofrer variações quando analisados por diferentes operadores. O objetivo do presente trabalho é avaliar a implementação de uma análise automatizada dos resultados através do processamento digital de imagens, que além de facilitar sobremaneira as rotinas laboratoriais, pode ser a chave para resultados com maior grau de precisão e repetibilidade, eliminando assim o viés subjetivo do analista. A nova metodologia de análise implica em menor interferência do analista na interpretação dos resultados. O método proposto foi testado em um conjunto de imagens e os resultados obtidos foram comparados com os valores da análise manual atualmente utilizada. Os resultados foram considerados promissores, pois a análise automatizada, além de reduzir significativamente o tempo de análise, possibilita uma padronização dos resultados. / The Molecular Biology Institute of Paraná (IBMP) acts in the production of inputs for detection of diseases. In partnership with Bio-Manguinhos (Fiocruz), it is currently responsible for manufacturing the amplification module of the Brazilian NAT KIT for HIV (AIDS), HCV (Hepatitis C) and HBV (Hepatitis B), besides other products for molecular diagnostics. The molecular test basically consists of amplifying the genetic material of the virus (DNA or RNA) through the real-time PCR (polymerase chain reaction) technique, which enables detection of the pathogen from small amounts of nucleic acid present in the sample. The PCR reaction occurs by the activity of Taq DNA Polymerase, a thermostable enzyme widely used for selective replication of DNA fragments. This enzyme was isolated from a thermophilic bacterium, called Thermus aquaticus and is produced by the IBMP, being considered an input of high criticality. One of the steps in controlling the production process of this enzyme is the evaluation of the enzymatic extract and the determination of the activity of the purified enzyme. The quantification method consists in evaluating the enzymatic activity through the conventional PCR methodology, followed by an analysis of the electrophoretic profile of the agarose gel samples. However, the methodology currently used presents a great subjectivity, since the interpretation of results can suffer variations when analyzed by different operators. The objective of the present work is to evaluate the implementation of an automated analysis of the results through digital image processing, which in addition to facilitating the laboratory routines, can be the key to results with a greater degree of precision and repeatability, thus eliminating the subjective bias of the analyst. The new methodology of analysis implies less interference of the analyst in the interpretation of the results. The proposed method was tested in a set of images and the obtained results were compared with the values of the manual analysis currently used. The results were considered promising because the automated analysis, besides significantly reducing the analysis time, allows a standardization of the results.

Page generated in 0.0556 seconds