1

Amplificador para registro de potenciais corticais

CARDOSO, Marcelo Ramos 02 February 2005 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2013-01-08T17:27:39Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AmplificadorRegistroPotenciais.pdf: 1573358 bytes, checksum: c63088be31befb563c0bd2c13bcb865f (MD5) / Approved for entry into archive by Ana Rosa Silva(arosa@ufpa.br) on 2013-01-16T15:29:40Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AmplificadorRegistroPotenciais.pdf: 1573358 bytes, checksum: c63088be31befb563c0bd2c13bcb865f (MD5) / Made available in DSpace on 2013-01-16T15:29:40Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AmplificadorRegistroPotenciais.pdf: 1573358 bytes, checksum: c63088be31befb563c0bd2c13bcb865f (MD5) Previous issue date: 2005 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Vários órgãos do corpo humano manifestam suas funções por meio de atividades elétricas. A medição desses e de outros biopotenciais pode fornecer indícios importantes que permitem o estudo do funcionamento real dos órgãos. Tais medições não constituem tarefa simples porque envolvem aquisição de dados de sinais cujas amplitudes podem ser na faixa entre 1 μV e 10 mV e também porque, no ambiente em que são feitos esses registros, estão presentes diversos tipos de sinais interferentes que causam degradação da relação sinal/ruído. Logo, o projeto do condicionador de biopotencial deve ser cercado de cuidados para que o circuito final reúna as melhores características de desempenho. Neste trabalho apresenta-se um estudo da origem dos biopotenciais, suas características, os circuitos utilizados para ganho e filtragem do sinal, além das interferências presentes nos sistemas de medições e alguns circuitos para redução desses sinais. É desenvolvido então, um condicionador para registro de biopotenciais corticais com blocos de filtragem e ganho do sinal em até 40 000. Os testes com o condicionador foram realizados registrando o potencial cortical provocado visual e o eletroencefalograma, e nos resultados experimentais é possível observar um desempenho satisfatório do equipamento. / Many organs in the human body manifest their functions through electric activities. Measurements of these and other biopotentials can provide vital clues that permits study as real functions of the organs. These measurements are not an easy task because envolves extremely low amplitudes data acquisition, between 1 μV and 10 mV, and also because these bioelectric recordings are often disturbed by an excessive level of interference presents, resulting in signal/noise degradation. Therefore, the biopotential amplifier project must be associated with precaution to final circuit can meet great characteristics in such signals measureming. This work shows a study about biopotentials origins, their characteristics, circuits used in signal amplifiering and filtering, interferences present in measurement systems and some circuits used to reduce such interferences. Thereafter, is developed a cortical biopotential amplifier with filtering and gain blocks. The tests with amplifier where realized by registering a visual evoked potential and the electroencephalogram. In the experimental results is possible to observe a satisfactory equipment performance.
2

SegmentaÃÃo dos vasos sanguÃneos pulmonares em imagens de tomografia computadorizada do tÃrax / Lung Blood Vessels Segmentation in Thoracic CT Scans

Alyson Bezerra Nogueira Ribeiro 04 March 2013 (has links)
Conselho Nacional de Desenvolvimento CientÃfico e TecnolÃgico / A anÃlise de imagens mÃdicas por meio de tÃcnicas de visÃo computacional tornou-se bastante promissora, principalmente pelo fato de aperfeiÃoar a acurÃcia diagnÃstica de diversas patologias. Por essas razÃo, a Pneumologia à considerada atualmente uma Ãrea de concentraÃÃo de projetos que envolvem mÃtodos de Processamento Digital de Imagens. A segmentaÃÃo de vasos sanguÃneos pulmonares à de bastante auxÃlio na detecÃÃo de cardiopatias pulmonares. Esse processo à realizado atravÃs da anÃlise dos resultados obtidos por exame de diagnÃstico por imagem, os quais se destacam as radiografias torÃcicas, tomografia computadorizada (TC) do tÃrax, ressonÃncia magnÃtica, cintilografia pulmonar e angiografia. A hipertensÃo pulmonar e o cÃncer sÃo exemplos de doenÃas que podem ser diagnosticadas com menor subjetividade ao realizar a segmentaÃÃo de vasos, visualizaÃÃo em trÃs dimensÃes e extraÃÃo de seus atributos. Devido a essa importÃncia, diversos algoritmos sÃo desenvolvidos com intuito de obter uma segmentaÃÃo Ãtima destas estruturas. Dentre estes, encontram-se os mÃtodos por contornos ativos, LÃgica Fuzzy, Crescimento de RegiÃes, Filtragem Multi-escalar 3D e algoritmo Expectation Maximization (EM). Nesta dissertaÃÃo, sÃo segmentados os vasos sanguÃneos pulmonares de imagens de tomografia computadorizada do tÃrax utilizando-se trÃs mÃtodos: uma combinaÃÃo de Crescimento de RegiÃes 3D controlado por uma funÃÃo de pertinÃncia gaussiana e limiarizaÃÃo; um mÃtodo hÃbrido de segmentaÃÃo por Conectividade Fuzzy e limiarizaÃÃo; por m, a segmentaÃÃo utilizando o classicador K-mÃdias. Os resultados obtidos pelas segmentaÃÃes sÃo analisados e comparados por meio de uma anÃlise dos coecientes de similaridade e sensibilidade. Os resultados da aplicaÃÃo dos trÃs mÃtodos sÃo caracterizados aceitÃveis e compatÃveis com os observados na literatura. / Medical image analysis using computer vision techniques has become quite promising because of its improvement on the diagnostic accuracy of various pathologies. For this reason, pulmonology became an area of high concentration of projects involving methods of Digital Image Processing. The blood vessels segmentation in the lung is an important aid in the detection of pulmonary heart diseases. This process is performed by analyzing the results obtained with known diagnostic imaging exams, like chest Xrays, computed tomography (CT) scan, magnetic resonance imaging, scintigraphy and angiography. Pulmonary hypertension and cancer are examples of diseases that can be diagnosed with less subjectivity if performing vessels segmentation, three-dimensional visualization and attribute extraction of these images. Thus, several algorithms are developed with the objective of obtaining an optimal segmentation of these structures. Among those algorithms are active contours, fuzzy logic, 3D Region Growing, 3D multi-scale ltering algorithm and Expectation Maximization (EM). In this study, the blood vessels were extracted from lung CT scans of the chest using three methods. The rst is a combination of 3D Region Growing controlled by a Gaussian membership function and thresholding, the second is a hybrid segmentation by thresholding and Fuzzy Connectedness. Finally,the third refers to segmentation using the K-means classier. The results and evaluation of applying these algorithms are presented.
3

Redes neurais artificiais aplicadas à segmentação de imagens / Artificial neural network applied to the segmentation of images

Albanez, Daniela de Oliveira 15 February 2017 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2017-02-24T13:58:39Z No. of bitstreams: 2 Dissertação - Daniela de Oliveira Albanez - 2017.pdf: 10127114 bytes, checksum: 4c037243629d84539257a8febc621fa8 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-02-24T13:59:39Z (GMT) No. of bitstreams: 2 Dissertação - Daniela de Oliveira Albanez - 2017.pdf: 10127114 bytes, checksum: 4c037243629d84539257a8febc621fa8 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-02-24T13:59:39Z (GMT). No. of bitstreams: 2 Dissertação - Daniela de Oliveira Albanez - 2017.pdf: 10127114 bytes, checksum: 4c037243629d84539257a8febc621fa8 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-02-15 / Image segmentation is one of image processing that problems that deserve special interest of the scientific community, given its real utility and application in various areas as medicine, geography, engineering, mathematics and computing, just to name a few. Much of the recent interest in segmentation has been motivated by the availability of satellite images on the Earth’s surface, which can be transformed into concrete knowledge, aiming at land use monitoring and data mining. This work proposes a new segmentation method, using Arficial Intelligence techniques, more specifically Artificial Neural Networks (ANNs), and compare its results of segmentation of satellite images with the original method. The binarized results are compared with the ground truth for the validation of the proposed segmentation method. Experimental results, quantative analysis of segmentation results, indicating that the proposed segmentation method generates better results and a decaying of 36.60% in the total average computacional time when compared with the original method. / Segmentação de Imagens é um dos problemas de processamento de imagens que mercê especial interesse da comunidade científica, tendo em vista sua real utilidade e aplicação em várias áreas do conhecimento como a medicina, geografia, engenharia, matemática e computação, só para citar algumas. Grande parte do interesse recente sobre segmentação foi motivado pela disponibilidade de imagens de satélite sobre a superfície da Terra, que podem ser transformadas em conhecimento concreto, visando o monitoramento e a mineração do uso da terra. Este trabalho propõe um novo método de segmentação, através de técnicas de Inteligência Artificial, mais especificamente pelas Redes Neurais Artificiais (RNA’s), e compara seus resultados de segmentação de imagens de satélite com o método original descrito na literatura. Os resultados binarizados são comparados com o ground truth para a validação do método de segmentação proposto. Resultados experimentais, realizados através da analise quantitativa dos resultados de segmentação, indicam que o método de segmentação proposto produz melhores resultados e uma redução média total do desempenho computacional de 36.60% em relação ao método original.
4

Análise de coerência entre cinemática e atividade muscular simulada em modelo de pêndulo invertido triplo na postura ereta quase-quieta antes e após uma perturbação mecânica / Coherence analysis between kinematic and simulated muscle activity in triple inverted pendulum model in quasi-quiet upright stance before and after a mechanical disturbance

Lemes, Thiago Santana 16 February 2017 (has links)
Submitted by Cássia Santos (cassia.bcufg@gmail.com) on 2017-04-17T14:12:44Z No. of bitstreams: 3 Dissertação - Thiago Santana Lemes - 2017 - Pt1.pdf: 10405713 bytes, checksum: aa367c643c35e55003006c669c0d140f (MD5) Dissertação - Thiago Santana Lemes - 2017 - Pt2.pdf: 16857396 bytes, checksum: cc1efd8dbb1e9b16c13abe4b9ded8d98 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-04-17T14:32:08Z (GMT) No. of bitstreams: 3 Dissertação - Thiago Santana Lemes - 2017 - Pt1.pdf: 10405713 bytes, checksum: aa367c643c35e55003006c669c0d140f (MD5) Dissertação - Thiago Santana Lemes - 2017 - Pt2.pdf: 16857396 bytes, checksum: cc1efd8dbb1e9b16c13abe4b9ded8d98 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-04-17T14:32:08Z (GMT). No. of bitstreams: 3 Dissertação - Thiago Santana Lemes - 2017 - Pt1.pdf: 10405713 bytes, checksum: aa367c643c35e55003006c669c0d140f (MD5) Dissertação - Thiago Santana Lemes - 2017 - Pt2.pdf: 16857396 bytes, checksum: cc1efd8dbb1e9b16c13abe4b9ded8d98 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-02-16 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The analysis of muscle activation and the modeling of the human body as a triple inverted pendulum reveal some interesting quasi-quiet standing posture maintenance mechanisms not observable in simpler models. Studies have shown some patterns of coordination between body segments and muscles when standing under an upright position, but due to the use of simpler models they did not reveal the exact role of the knee in the upright posture. In this study, 25 young people participated in an experiment, in which kinematic data and force platforms were collected. A complex coherence and phase analysis was used between simulation of muscle activity, body segment kinematics and inverse dynamics, in order to verify if there is a difference between the signals before and after an induced disturbance, and how the trunk and knee joint behaves in a triple inverted pendulum model of the body. Complex coherence is an analysis in the frequency domain and reveals how well two signals correspond to one another. The activation of nine muscles was simulated, and the resulting torque using the inverse dynamics at the ankle, knee and hip joints was calculated, both using OpenSim software. The trunk worked in phase with leg and thigh at low frequencies, and switched to anti-phase at high frequencies. However, the trunk does not show significant coherence with any of the muscles analyzed besides moving in delay with respect to the torque in the hip, which suggests that the trunk oscillations occur passively. However, thigh and leg muscles activated in phase with trunk muscles, suggesting a relationship between the movement of these segments. However, it has to be considered that there are limitations in the simulations of muscle activation, so that future experimental studies that confirm the data presented here are necessary. The results show no significant difference between the pre-perturbation and post-perturbation oscillations, but there is a greater variability in the angular oscillations of the segments, indicating the challenge imposed to the postural control system and the work of recovering the disturbance. Patterns of muscular activation in the ankle and pelvis were compatible with previous studies, acting to maintain upright posture. / A análise da ativação muscular e a modelagem do corpo humano como um pêndulo invertido triplo revelam alguns interessantes mecanismos de manutenção da postura ereta quase-quieta não observáveis em modelos mais simples. Estudos já demonstraram alguns padrões de coordenação entre os segmentos e músculos do corpo quando este se encontra sob uma perturbação em posição ereta, mas devido ao uso de modelos mais simples não revelaram o exato papel do joelho na postura ereta. Neste estudo, 25 jovens participaram de um experimento, no qual foram coletados dados cinemáticos e de plataformas de força. Foi utilizada uma análise de coerência complexa e de fase entre a simulação da atividade muscular, a cinemática dos segmentos corporais e a dinâmica inversa, com o objetivo de verificar se existe diferença entre os sinais antes e após uma perturbação induzida, e como se comportam tronco e articulação do joelho em um modelo de pêndulo invertido triplo do corpo. A coerência complexa é uma análise no domínio da frequência e revela o quão bem dois sinais correspondem um ao outro. A ativação de nove músculos foi simulada, e o torque resultante usando a dinâmica inversa nas articulações do tornozelo, joelho e quadril foi calculado, ambos utilizando o software OpenSim. O tronco trabalhou em fase com perna e coxa em baixas frequências, e muda para anti-fase em altas frequências. No entanto, o tronco não apresenta coerência significativa com nenhum dos músculos analisados além de se mover em atraso com relação ao torque no quadril, o que sugere que as oscilações do tronco ocorrem de forma passiva. Entretanto, músculos da coxa e da perna ativaram em fase com músculos do tronco, sugerindo relação entre a movimentação desses segmentos. Porém, há de se considerar que há limitações nas simulações da ativação muscular, de forma que estudos experimentais futuros que confirmem os dados ora apresentados são necessários. Os resultados encontrados não apontam diferença significativa entre as oscilações pré perturbação e pós perturbação, mas existe uma maior variabilidade nas oscilações angulares dos segmentos, indicando o desafio imposto ao sistema de controle postural e o trabalho de recuperação da perturbação. Padrões de ativação muscular no tornozelo e na pelvis foram compatíveis com estudos anteriores, agindo na manutenção da postura ereta.
5

Proposal of a Java Front-end for voice synthesizer based on MBROLA / Proposta de um Front-end em Java para sintetizador de voz baseado no MBROLA

NÃcolas de AraÃjo Moreira 02 September 2015 (has links)
CoordenaÃÃo de AperfeÃoamento de Pessoal de NÃvel Superior / It is estimated that, in Brazil, about 3.46% of population presents difficulty to see and 1.6% is blind. The lack of adequate inclusive tools imposes many restrictions on the life of these people, in other words, non-accessible hardware and software create a negative impact on academic, professional and personal life. In this context, the present thesis aims to develop a an accessible system for digital inclusion of blind users, since the existing systems present many disadvantages as low quality or cost that make impossible the daily use. The system is composed by a multiplatform Java front-end. In addition, the system is free to reach the maximum numbers of users as possible and to be modified and improved by the community. The developed solution was tested, presenting a medium intelligibility rate of 79% and naturalness classified as "reasonable" by a group of 20 users. In the end, the system proved to be feasible, filling an existing gap on Brazilian software marked, allowing greater inclusion of blind users to digital resources. / Estima-se que, no Brasil, cerca de 3,46% da populaÃÃo apresenta grande limitaÃÃo de visÃo e 1,6% seja totalmente incapaz de enxergar. A falta de meios de inclusÃo adequados impÃe uma sÃrie de restriÃÃes na vida destas pessoas, em outras palavras, ferramentas de hardware e software nÃo acessÃveis geram impacto negativo na vida acadÃmica, pessoal e profissional. Dentro desse contexto, a presente DissertaÃÃo tem por objetivo principal desenvolver um sistema para inclusÃo digital de deficientes visuais. O sistema à composto por um front-end multiplataforma para o sintetizador de voz MBROLA e um conjunto programas acessÃveis, que inclui editor de texto, cliente de chat, lente de aumento virtual, entre outros, desenvolvido em Java a fim gerar um software multiplataforma. AlÃm disso, o sistema à gratuito e livre para que possa atingir o maior nÃmero de usuÃrios possÃvel e ser modificado e aprimorado pela comunidade. A soluÃÃo desenvolvida foi testada em campo, apresentando Ãndice de inteligibilidade mÃdio de 79% e com naturalidade classificada como razoÃvel em um grupo de 20 usuÃrios. Por fim, o sistema se mostrou viÃvel, vindo a preencher uma lacuna existente no mercado brasileiro de softwares, permitindo maior inclusÃo dos deficientes visuais aos meios digitais.
6

Uma nova abordagem baseada em autovalores para a estimação de posições de fontes cerebrais utilizando sinais eletroencefalográficos / A new approach for cerebral sources position estimation based on eigenvalues using electroencephalographic signals

Cruz, Lucas Fiorini 18 May 2018 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2018-08-13T14:49:42Z No. of bitstreams: 2 Dissertação - Lucas Fiorini Cruz - 2018.pdf: 23542908 bytes, checksum: 75e04989d0719a9b5d0d22225c38ce7a (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2018-08-14T11:35:12Z (GMT) No. of bitstreams: 2 Dissertação - Lucas Fiorini Cruz - 2018.pdf: 23542908 bytes, checksum: 75e04989d0719a9b5d0d22225c38ce7a (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-08-14T11:35:12Z (GMT). No. of bitstreams: 2 Dissertação - Lucas Fiorini Cruz - 2018.pdf: 23542908 bytes, checksum: 75e04989d0719a9b5d0d22225c38ce7a (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-05-18 / Electroencephalography (EEG) measurements are widely used in clinical assessments for research due to its noninvasive nature and for providing several informations on the neural activity associated to both neural functions and disorders, including epilepsy syndromes. In cases related with partial epilepsy, surgical interventions are recommended and the accurate location of the seizure becomes a sine qua non prerequisite for those procedures. Brain source position estimation can help in the selection and classification of brain spots. In this sense, for control purposes, this work begins with the development of a mathematical model that is more electromagnetically representative than the usual model, presenting different aggregate characteristics such as refraction and, especially, frequency dependent attenuation of the wave. We also propose a new method that estimates the source positions from spectral peaks produced by the eigenvalues of the sum of the spatial covariance matrix of the EEG signals and a spatial covariance matrix related to a simulated source that is numerically swept throughout every point on different horizontal layers of the brain. The key approach was to select the eigenvalues that were less affected by the noise and use them to produce the search spectrum. In order to assess the accuracy and robustness of the proposed method, we compared its RMSE (Root Mean Square Error) performance at different SNRs (Signal-to-Noise Ratio) to those of MUSIC (Multiple Signal Classification), a method based on orthogonal subspaces, and NSF (Noise Subspace Fitting), a method based on subspace fitting. The results were produced for both the usual and proposed signal model in order to evaluate their accuracy. Subsequently, the signal models were compared after spatial filtering, aiming the determination of the waveform of a particular source. The proposed approach presents the lowest threshold SNR and the highest accuracy under noisy conditions for all analyzed cases and for both models. The new approach for the signal model made the estimation more accurate in all the studied cases, besides providing greater accuracy on spatial filtering, when compared to the usual model. / Sinais de eletroencefalografia (EEG) são amplamente utilizados em análises clínicas e para fins de pesquisas devido ao seu caráter não invasivo e por possuírem informações sobre as atividades neurais ligadas às funções e anomalias cerebrais, incluindo a epilepsia. Nos casos relacionados à epilepsia parcial, intervenções cirúrgicas são recomendadas e a precisa localização da região epileptogênica é uma condição sine qua non para tal procedimento. Nesse sentido, para fins de controle, este trabalho se inicia com a proposta de um novo modelo matemático das atividades elétricas do cérebro que, quando comparado ao modelo Dipolo elétrico - encontrado na literatura - aproxima-se mais do real, apresentando diferentes características agregadas como refração e, especialmente, atenuação dependente da frequência da onda. Em outro plano, também é proposto um novo método que estima as posições das fontes elétricas cerebrais a partir de picos espectrais produzidos por autovalores da soma da matriz de covariância espacial do sinal EEG com uma matriz de covariância espacial relacionada a uma fonte simulada que, numericamente, é posicionada em pontos de diferentes camadas horizontais do cérebro. A chave para essa abordagem é selecionar os autovalores menos afetados pelo ruído e utilizá-los para construir o espectro de busca. Para analisar a robustez e acurácia do método, avalia-se o seu desempenho em relação à raiz do erro médio quadrático (REMQ) para diferentes valores de relação sinal-ruído (SNR), comparando-o ao algoritmo MUSIC (Multiple Signal Classification), baseado em subespaços ortogonais, e ao NSF (Noise Subspace Fitting), método baseado em “distância” entre subespaços (subspace fitting). Todos os resultados são gerados para o modelo de sinal usual e o proposto, com fim de avaliar a acurácia conferida a cada um destes. Posteriormente, os modelos de sinal são comparados quanto à filtragem espacial, buscando a determinação da forma de onda de uma fonte em particular. A abordagem proposta apresenta uma menor SNR de limiar de desempenho e uma maior acurácia sob condições ruidosas em todos os casos analisados e nos dois modelos. O novo modelo do sinal tornou a estimação DOA mais precisa em todos os casos estudados, além de ter conferido maior precisão à filtragem espacial, quando comparado ao modelo usual.
7

Desenvolvimento de um sistema de monitoramento de sinais de ECG e temperatura utilizando dispositivos móveis / Development of a system for monitoring ECG and temperature signals using mobile devices

Moribe, Sergio 15 March 2016 (has links)
CAPES; CNPq; Fundação Araucária / Este trabalho teve por objetivo o desenvolvimento de um sistema de monitoramento de sinais de ECG e temperatura, com o propósito de dar mobilidade a pessoas que necessitam de monitoramento contínuo de alguns sinais fisiológicos, tais como pessoas idosas e/ou pessoas com deficiências cardíacas ou até mesmo para atletas que desejam melhorar seu desempenho através do monitoramento de seu condicionamento físico. Foram realizadas pesquisas dos equipamentos similares que existem atualmente no mercado e que estão sendo desenvolvidos para um embasamento técnico do protótipo desenvolvido. O sistema foi desenvolvido utilizando um microcontrolador de baixo custo e consumo para aquisição dos sinais fisiológicos e um módulo Bluetooth para comunicação com um dispositivo móvel que apresenta grande capacidade de processamento e recursos para realizar o armazenamento de dados e a interface com um sistema de monitoramento para avaliação médica remota, garantindo a mobilidade, segurança e melhoria na qualidade de vida de idosos e pacientes. Os principais sinais fisiológicos são os sinais vitais, que são as funções mais básicas do corpo, tais como, temperatura corporal, frequência cardíaca, frequência respiratória e pressão arterial. No protótipo proposto, foi incorporado o monitoramento da temperatura corporal e do eletrocardiograma (ECG) completo com as 12 derivações. A frequência respiratória e pressão arterial não foram contempladas no protótipo devido à complexidade de implementação de muitos sinais fisiológicos em um único equipamento. Para definição do hardware e minimizar o risco de futuros problemas, foram também realizados testes com ferramentas de desenvolvimentos disponibilizados pelos fabricantes dos principais componentes e que também são expostos neste trabalho. Pode-se concluir que os objetivos iniciais foram alcançados pois foi desenvolvido um protótipo para monitoramento remoto de sinais de ECG e temperatura utilizando um aplicativo Android. O protótipo foi testado utilizando-se sinais de um simulador de ECG e um sensor de temperatura, atendendo às principais funcionalidades requeridas para o sistema. / This work aims to develop a system for monitoring ECG and temperature signals with the purpose of giving mobility to people requiring continuous monitoring of some physiological signals, such as the elderly and/or individuals with heart failure or even for athletes who wish to improve their performance by monitoring their fitness. Research of similar equipment that there are currently on the market and that are being developed was made for a technical base of the prototype to be developed. The system was developed using a low cost and low consumption microcontroller for the acquisition of physiological signals and a Bluetooth module for communication with a mobile device having large capacity and processing resources to perform data storage and interface with a monitoring system for remote medical evaluation, ensuring mobility, safety and improved quality of life of elderly and patients. The main physiological signals are vital signals, which are the most basic body functions such as body temperature, heart rate, respiratory rate and blood pressure. In the proposed prototype, monitoring body temperature and complete 12-lead electrocardiogram (ECG) was incorporated. The respiratory rate and blood pressure were not included in the prototype due to the complexity of implementation of many physiological signals in a single equipment. For the hardware definition and to minimize the risk of future problems, tests have also been done with development tools available from manufacturers of the main components and which are also presented in this work. It is possible to conclude that the initials objectives were achieved bacause a prototype was developed for remote monitoring of ECG and temperature signals using an Android application. The prototype was tested using an ECG simulator and a temperature sensor, attending the main required features for the system.
8

Engenharia clínica aplicada à análise da variabilidade de parâmetros de referência para classificação da função pulmonar de adultos brasileiros / Clinical engineering applied to the analysis of the variability of reference parameters for classification of pulmonary function in brazilian adults

Silva, Paulo Roberto da 12 December 2016 (has links)
Uma das aplicações básicas da engenharia biomédica se refere aos testes de equipamentos de uso clínico, a avaliação de sua natureza, acessibilidade e/ou suas características. No âmbito da avaliação do sistema respiratório, estão disponíveis diferentes parâmetros de referência (PR) para o teste de espirometria, um dos principais testes de função pulmonar, que permite medir: volumes, capacidades e fluxos pulmonares. Estes PR baseiam-se principalmente em dados étnicos, idade e gênero de indivíduos saudáveis, mas havendo diferenças entre populações avaliadas, como no Brasil com sua grande diversidade de raças e etnias, pode haver erro diagnóstico. Em razão disto, o objetivo deste estudo foi analisar três dos principais PR utilizados nesta população: PR-P (de Pereira e colaboradores de 2007), PR-K ( de Knudson e colaboradores de 1983) e PR-Q (de Quanjer e colaboradores de 2012). Procedeu-se um estudo exploratório descritivo com 683 indivíduos (180 homens e 503 mulheres) entre 24 e 59 anos, em boas condições de saúde, praticantes de exercícios físicos regulares com frequência mínima de duas vezes por semana. Foi aplicada anamnese, coletados dados de massa, estatura e realizada a espirometria forçada (espirômetro bidirecional - Care Fusion MicroLoop) e as variáveis respiratórias avaliadas foram VEF1, CVF, FEF75 e PFE. Como principais resultados verificou-se que a idade média foi de 42 anos (masculino: 40,6 anos; feminino: 44,4 anos); IMC médio de 26 Kg/m² (masculino: 26,26 Kg/m²; feminino: 26,44 Kg/m²); e tempo da prática de exercícios físicos médio de 52 meses (masculino: 66,9 meses; feminino: 37,9 meses). Ao se analisar a variação dos parâmetros de referência para classificação da função pulmonar entre os três protocolos testados, encontrou-se diferença estatisticamente significativa (p<0,05) entre CVF, VEF1, FEF75 e PFE para os valores previstos e atingidos em todos os PR, além de sinais restritivos e obstrutivos. Para o PR-P, mesmo com indivíduos com características assintomáticas e praticantes de exercícios físicos, 17,2% dos indivíduos foram classificados com algum grau de restrição e 17,3% com obstrução, distanciando-se do PR-K e PR-Q que, respectivamente apresentaram valores para restritivo de 7,0% e 12,8% e para obstrutivos de 7,1% e 4,8%. Conclui-se que os respectivos PR podem induzir a erros, levando a classificações diferentes, podendo um mesmo indivíduo ser considerado em estado de normalidade, restritivo ou obstrutivo, a depender do protocolo escolhido. O estado nutricional interferiu na função respiratória no gênero masculino ao se identificar associação significativa entre o estado nutricional e o teste de função pulmonar, x² = 9,80 (p = 0,04). Desta forma, homens acima do peso tiveram 1,9 vezes mais risco de apresentar o teste de função pulmonar insuficiente, mesmo praticando exercícios físicos regulares. Não houve associação significativa em nenhum dos gêneros entre o teste de função pulmonar e o tempo de prática de exercícios físicos. O teste de correlação de Pearson, confirmou a inexistência de correlação entre as variáveis VEF1, PFE e CVF com o tempo de prática para ambos os gêneros. / One of the basic applications of biomedical engineering refers to the testing of clinical use equipment, the assessment of its nature, accessibility and / or its features. In the evaluation of the respiratory system, are available different parameters of reference (PR) for the spirometry test, one of the main pulmonary function tests, which can measure: volumes, capacities and pulmonary flows. These PR based mainly on ethnic data, age and gender in healthy subjects, but with differences between populations studied, as in Brazil with its great diversity of races and ethnic groups, there may be misdiagnosis. Because of this, the objective of this study was to analyze in this population, three of the most used PR: PR-P (Pereira et al., 2007), PR-K (Knudson et al., 1983) and PR-Q (Quanjer et al., 2012). The procedure was a descriptive exploratory study with 683 subjects (180 men and 503 women) between 24 and 59 years, in good health, regular physical exercises practitioners with minimum frequency of twice a week. Anamnesis was applied, collected data of mass and height, performed forced spirometry (bidirectional spirometer - Care Fusion Microloop) and the following respiratory variables were measured, FEV1, FVC, PEF and FEF75. With the main results it was found that the average age was 42 years (male: 40.6 years; women: 44.4 years); BMI average of 26 kg / m² (male: 26.26 kg / m²; female: 26.44 kg / m²); and time the average physical exercises practice 52 months (male: 66.9 months; female: 37.9 months). When analyzing the variation of the reference parameters for pulmonary function classification between the three protocols tested, we found a statistically significant difference (p <0.05) between FVC, FEV1, PEF and FEF75 to the levels required and achieved in all PR, as well as restrictive and obstructive signs. For the PR-P, even with individuals with asymptomatic characteristics and practitioners of physical exercises, 17.2% of subjects were classified with some degree of restriction and 17.3% with obstruction, away from the PR-K and PR-Q which respectively had values for restrictive of 7.0% and 12.8% and for obstruction of 7.1% and 4.8%. We conclude that these PR may induce to errors, leading to different rating, where one individual can be considered in normal state, restrictive or obstructive, depending on the chosen protocol. It was identified that nutritional status interfere with respiratory function, demonstrating significant association between nutritional status and pulmonary function test for males, x² = 9.80 (p = 0.04). Thus, overweight men had 1.9 times more risk to have the insufficient lung function test, even practicing regular physical exercises. There was no significant association in any of the genres between the pulmonary function test and the time of physical activity. The Pearson correlation test confirmed the lack of correlation between the FEV1, FVC and PEF with practice time for both genders.
9

Avaliação do padrão de desempenho das equipes técnicas de mamografia frente ao uso de tecnologias digitais / Grading of the performance of the technical mamography teams, in lieu of the use of digital technologies

Oliveira, Evelyn Rosa de 07 April 2017 (has links)
Este estudo apresenta uma análise de rejeição, realizada na clínica Diagnóstico Avançado Por Imagem – DAPI, com dados de 647 mamografias rejeitadas realizadas de março a novembro de 2015, antes e após treinamentos realizados com a equipe técnica de mamografia, para análise do desempenho. As informações foram coletadas na base de dados do software de análise de rejeição dos mamógrafos, e incluem: incidência; quantidade de repetições; motivo da repetição; identificação da profissional; compressão do exame rejeitado e do exame aceito. Observou-se que após o treinamento os índices de rejeição por posicionamento (a maior causa das rejeições) foram reduzidos em 2%. Identificou-se que as profissionais desenvolveram critérios mais rigorosos, o que também contribuiu para aumento das repetições após o treinamento. A incidência mais rejeitada foi a Crânio Caudal Direita – CCD, tanto antes (32%) quanto após o treinamento (36%). A análise do desempenho da equipe técnica em relação aos critérios de qualidade em mamografia digital pôde ser realizada, uma vez que houve a análise individual das profissionais para contribuição da qualificação da equipe e aumento da qualidade dos exames. A profissional “A”, que possuía o maior índice de rejeição por posicionamento, após o treinamento houve uma redução de 17% das repetições devido a posicionamento inadequado. Foram identificadas imagens com qualidade aceitável que foram rejeitadas desnecessariamente: 8% antes e 3,6% após o treinamento. Antes do treinamento, a equipe técnica realizava as mamografias com valores de compressão entre 80 a 89 N, e após o treinamento a maioria dos exames foi realizada com 90 N ou mais. Esse aumento resulta em exames com melhor qualidade e menor dose para a paciente. / This study presents a rejection analysis performed at the clinic Diagnóstico Avançado Por Imagem - DAPI, with data from 647 rejected mammograms performed three months before and three months after a training session of the mammography team, to analyze the performance of them after the training. The information was collected in the database of mammography rejection analysis software,these data include: Incidence; Number of repetitions; Reason for the repetition; Identification of the professional; Rejection examination and accepted examination. It was observed that, after the training, the rejection indexes by positioning (the greatest cause of the rejections) were reduced. It was observed that the group developed rigorous criteria, which also contributed to increase the repetitions after the training. The most rejected incidence was Cranio Caudal Right - CCD, both before (32%) and after training (36%).The analysis of the performance of the technical team, in relation to the quality criteria in digital mammography, could be performed by the individual analysis of the professionals to contribute to the qualification of the team and to increase the quality of the exams. The "A" professional, who had the highest index of rejection by positioning, after the training there was a reduction of 17% of the repetitions due to improper positioning. Acceptable quality images have been identified that are rejected unnecessarily 8% before and 3,6% after training. Before the training, the technical team performed the mammograms with values of compression between 80 and 89 N, and after training most of the exams were performed with 90 N or more. This increase which results in better quality tests and lower dose for the patient.
10

Método para reconhecimento de vogais e extração de parâmetros acústicos para analises forenses / Method for recognition of vowels and extraction of acoustic parameters for forensic analysis

Dresch, Andrea Alves Guimarães 14 December 2015 (has links)
Exames de Comparação Forense de Locutores apresentam características complexas, demandando análises demoradas quando realizadas manualmente. Propõe-se um método para reconhecimento automático de vogais com extração de características para análises acústicas, objetivando-se contribuir com uma ferramenta de apoio nesses exames. A proposta baseia-se na medição dos formantes através de LPC (Linear Predictive Coding), seletivamente por detecção da frequência fundamental, taxa de passagem por zero, largura de banda e continuidade, sendo o agrupamento das amostras realizado por meio do método k-means. Experimentos realizados com amostras de três diferentes bases de dados trouxeram resultados promissores, com localização das regiões correspondentes a cinco das vogais do Português Brasileiro, propiciando a visualização do comportamento do trato vocal de um falante, assim como detecção de trechos correspondentes as vogais-alvo. / Forensic speaker comparison exams have complex characteristics, demanding a long time for manual analysis. A method for automatic recognition of vowels, providing feature extraction for acoustic analysis is proposed, aiming to contribute as a support tool in these exams. The proposal is based in formant measurements by LPC (Linear Predictive Coding), selectively by fundamental frequency detection, zero crossing rate, bandwidth and continuity, with the clustering being done by the k-means method. Experiments using samples from three different databases have shown promising results, in which the regions corresponding to five of the Brasilian Portuguese vowels were successfully located, providing visualization of a speaker’s vocal tract behavior, as well as the detection of segments corresponding to target vowels.