Estudo de vida em fadiga de parafusos pediculares revestidos com hidroxiapatita

Larrubia, Davis Machado 30 August 2013 (has links)
Made available in DSpace on 2016-06-02T19:12:33Z (GMT). No. of bitstreams: 1 5545.pdf: 5030792 bytes, checksum: db0e89c0cabf8fcafd5e7da0160756a0 (MD5) Previous issue date: 2013-08-30 / The search for new materials or changes in the manufacture process for the surgical implant companies have been considered one the most challenging issues for the engineering in order to supply high performance products and minimize the damage to the post-operated patient, reducing the recovery time through the improved acceptance and stability of the organism regarding the implanted medical device. Alternatives for the decrease in the time to reach the arthodesis can be obtained through the Surface Treatment technique. The possible use of bioceramics with coating in metallic parts, may increase the bone growth rate of the deposited bioceramic when the adequate parameters are used, although the thermal spray process may impact the fatigue life. This study intends to analyses the life of dynamic loading of a Pedicular Fixation System with the presence of a coated hydroxyapatite film deposited on the surface of the screws through the Flame Spray technique, using a methodology in according with the prescribed by the preface of the standard ASTM F 1717 (Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model). The mechanical properties of the coating were found satisfactory, although changes in the coating process are required in order to reach the correct Ca/P ratio. / As pesquisas por novos materiais ou modificações de processamento para as indústrias de implantes têm sido alguns dos grandes desafios da engenharia para fornecer produtos de alto desempenho e minimizar os danos no pós-operatório de pacientes submetidos à intervenção cirúrgica, além de diminuir o tempo de recuperação dos mesmos através de maior aceitação e estabilidade do organismo ao produto médico implantado. Alternativas para diminuir o tempo de obtenção da artrodese podem ser obtidas através de técnicas de Engenharia de Superfície. A possibilidade de utilização de biocerâmicas como recobrimento de peças metálicas, pode proporcionar maior taxa de crescimento ósseo quando depositada nos parâmetros adequados, embora o processo de aspersão térmica possa ocasionar alterações significativas da vida em fadiga do corpo metálico. Este estudo busca verificar a vida sob compressão dinâmica de um sistema de fixação pedicular que possui seus parafusos recobertos por hidroxiapatita através da técnica de Flame Spray seguindo os prefácios da norma ASTM F 1717 (Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model). O comportamento mecânico da peça recoberta se mostrou satisfatório, entretanto há a necessidade de alterações nos parâmetros de processo para que a correta relação Ca/P seja obtida.
12

Influência do tipo de conexão no torque de desaperto de parafusos e pilares em próteses sobre implantes convencionais e zigomáticos

Coró, Vitor 19 February 2009 (has links)
In cases of upper edentulous patients with atroffic maxilla, the zigomatic implant is one of the techniques used for rehabilitation with implanted fixed prosthesis. The screw s loosening is one of the main problems related to this type of prosthesis. The aim of this work was to evaluate the golden and abutments screws loosening in fixed prosthesis over two conventional implants and two zigomatic implants before and after fatigue test. Five samples with external hexagonal junctions (HE) and five with internal conical junctions (CM) had been used. Each specimen with two anterior conventional implants and two distal zigomatic implants. The respective abutments had been installed on the implants and metallic structures of screwed fixed prosthesis had been casted. The specimens had been submitted to four fatigue protocols with different load levels in cantilever and different number of cycles. Untorque values of retaining and abutment screws had been verified before and after each cyclic loading with a digital torquemeter. The prosthetic screws had had reduction in the untorques values when compared with the iniitial torques, but there was no difference between the two interfaces in study. The untorque values of the HE abutments screws after all cycles, had a reduction in 51,56% of the cases. 60,6% f these in zigomatic implants and 39,4% in conventional implants. The screws of the CM abutments had untorque loss in 39,58% of the cases. 21,05% had ocurred in zigomatic implants and 78,95% in conventional implants. The variation of junction type does not interfere in the untorque of retention screws of the prosthesis. The mechanical behavior was different when comparing CM and HE abutment screws. In the HE specimens the torque loss was greater in the zigomatic implants whereas in the CM specimens, the absolute untorque values of the zigomatic implants increased after the fatigue test. / Em casos de pacientes edêntulos superiores com maxilas atróficas, a utilização de implantes zigomáticos é uma das técnicas utilizadas para reabilitação com prótese fixa sobre implantes. Contudo, o desaperto de parafusos é um dos principais problemas relacionados a este tipo de prótese. O objetivo deste trabalho foi avaliar a diminuição de torque de desaperto dos parafusos protéticos e de intermediários em próteses fixas confeccionadas sobre dois implantes convencionais e dois zigomáticos, antes e após ensaio de fadiga. Foram utilizados cinco modelos com junções hexagonais externas (HE) e cinco com junções cônicas internas ou cone-morse (CM). Cada amostra com dois implantes convencionais anteriores e dois implantes zigomáticos distais. Sobre os implantes foram instalados pilares respectivos e confeccionadas estruturas metálicas fundidas de uma prótese fixa parafusada. As amostras foram submetidas a quatro níveis de carga em cantilever e diferentes números de ciclos. Utilizando torquímetro digital foram determinados valores de desaperto dos parafusos de retenção e dos pilares antes e após cada ciclagem. Os parafusos protéticos tiveram diminuição nos torques de desaperto quando comparados aos torques iniciais, mas não houve diferença entre os tipos de junção. Nos parafusos dos pilares HE observando os valores de desaperto após todos os ciclos, houve diminuição do torque de desaperto em 51,56% dos casos. Destes, 60,6% nos implantes zigomáticos e 39,4% nos convencionais. Os parafusos dos pilares CM tiveram valor de torque diminuído em 39,58% dos casos. Destes, 21,05% ocorreram nos zigomáticos e 78,95% nos convencionais. Nas amostras HE houve maior perda de torque para os implantes zigomáticos enquanto que nas CM ocorreu o contrário, sendo que em valores absolutos de torque de desaperto, os pilares CM dos zigomáticos apresentaram aumento de torque de desaperto após o ensaio de fadiga. Desta forma, a variação do tipo de junção não interferiu no torque de desaperto dos parafusos de retenção das próteses. Houve alteração no comportamento mecânico quando comparados parafusos de pilares HE e CM. / Mestre em Odontologia
13

Eficiência do processo de tratamento primário de efluentes domésticos com o uso da prensa parafuso (screw press)

VALE, Grazielle Barbosa do 28 August 2018 (has links)
Submitted by Mario BC (mario@bc.ufrpe.br) on 2018-11-13T11:43:40Z No. of bitstreams: 1 Grazielle Barbosa do Vale.pdf: 2963370 bytes, checksum: 5f3cb9e10273cc2feb9f7681ac68719e (MD5) / Made available in DSpace on 2018-11-13T11:43:40Z (GMT). No. of bitstreams: 1 Grazielle Barbosa do Vale.pdf: 2963370 bytes, checksum: 5f3cb9e10273cc2feb9f7681ac68719e (MD5) Previous issue date: 2018-08-28 / Accelerated urban growth is aligned with the increase in the consumption of natural resources, especially in water for human consumption, which directly results in the production of sanitary sewage in Brazil. In Brazil about 51.92% of the population has access to sanitary sewage and only 44.92% of the country's sewage is treated. The State of Pernambuco generates a volume of sewage in the order of 1.5 million m³ per day, based on its population of about 9.5 million inhabitants, of which only 20% has access to the sewage network. Another factor linked to sanitary sewage is sludge generated at Wastewater Treatment Plants, which, although corresponding to only 1-2% of the volume of treated sewage, is considered complex and demands high costs. Thus, the objective of this work is to evaluate the efficiency of a process of primary treatment of domestic effluents with the use of the screw press. In order to study the efficiency of this primary treatment process using the screw press, a domestic effluent treatment station was installed that implemented the equipment. A data survey was carried out, through photographic records and semi-structured interviews with a thematic roadmap, to identify the effluent and sludge treatment processes. In order to characterize the raw and treated effluent, monthly collections were carried out during the period from 01/2014 to 06/2018, with variations in the quality of the primary treatment during the period in which the drying beds were used for sludge dewatering and a period in which the "ETE A" already operated with the screw press. The physico-chemical collections and analyzes were carried out with reference to the methodology described in the Standard Methods for the Examination of Water and Wastewater. The efficiency of the primary treatment with the use of the screw press was obtained by means of a comparison between the results in the period that the TEE operated using drying beds (2014-2015) with the results after incorporation of the screw press to the process (2016-2018). The characterization of the sludge indicated a high degree of mineralization due to its composition having high plot of Volatile Suspended Solids. The solids content of 12% above the primary sludge characteristic range (2-7%) indicates the need for a higher frequency of removal. With the increase of efficiency in the removal of BOD the unit started to release less polluting in the receiving body reducing the environmental impacts. The average efficiency for the DBO parameter in 2014 to 2015 was 26% and with the use of the screw press and from 2016 to 2018 the result was 51%, a result higher than expected for primary processes (30%). The screw press showed to be efficient in the removal of organic load, with removal 220% greater than the drying bed process. Screw press has proven to be advantageous in terms of decreasing the time and increase of sludge processing capacity, low operator exposure to unhealthy conditions and reduced labor requirements, mitigation of the release of unpleasant odors and proliferation of insect flies. / O crescimento urbano acelerado alinha-se com o aumento do consumo dos recursos naturais em especial na água para consumo humano, que resulta diretamente com a produção de esgotamento sanitário no Brasil. No Brasil cerca de 51,92% da população tem acesso a rede de esgoto sanitário e apenas 44,92% dos esgotos do país são tratados. O Estado de Pernambuco gera um volume de esgoto na ordem de 1,5 milhão de m³ por dia, baseado na sua população de cerca 9,5 milhões de habitantes, dos quais apenas 20% tem acesso à rede de esgoto. Outro fator atrelado ao esgotamento sanitário é o lodo gerado nas Estações de Tratamento de Efluentes, que apesar de corresponder a apenas 1-2% do volume de esgoto tratado, o seu gerenciamento é considerado complexo e demanda custos elevados. Assim, o objetivo desse trabalho consiste em avaliar a eficiência de um processo de tratamento primário de efluentes domésticos com a utilização da prensa parafuso (screw press). Para o estudo da eficiência deste processo de tratamento primário com uso da prensa parafuso foi selecionada uma Estação de Tratamento de Efluentes domésticos que implementou a utilização do equipamento. Realizou-se um levantamento de dados, por meio de registros fotográficos e entrevistas semiestruturadas com roteiro temático, para a identificação dos processos de tratamento de efluente e do lodo. Para caracterização do efluente bruto e tratado foram realizadas coletas mensais durante o período de 01/2014 a 06/2018, verificando-se variações na qualidade do tratamento primário durante o período em que eram utilizados os leitos de secagem para desaguamento do lodo e um período em que a “ETE A” já operava com a prensa parafuso. As coletas e análises físico-químicas foram realizadas tomando como referência a metodologia descrita no Standard Methods for the Examination of Water and Wastewater. A eficiência do tratamento primário com uso da prensa parafuso foi obtida por meio de um comparativo entre os resultados no período que a ETE operava utilizando leitos de secagem (2014-2015) com os resultados após incorporação da prensa parafuso ao processo (2016-2018). A caracterização do lodo indicou um alto grau de mineralização devido sua composição ter alta parcela de Sólidos Suspensos Voláteis. O teor de sólidos de 12% acima da faixa característica de lodo primários (2-7%) indica a necessidade de maior frequência de remoção. Com o aumento da eficiência na remoção de DBO a unidade passou a lançar menos poluente no corpo receptor reduzindo os impactos ambientais. A média da eficiência para o parâmetro DBO em 2014 a 2015 foi de 26% e com a utilização da prensa parafuso e de 2016 a 2018 foi alcançado o resultado de 51%, resultado superior ao esperado para processos primários (30%). A prensa parafuso mostrou-se eficiente na remoção de carga orgânica, com remoção 220% maior que o processo com leitos de secagem. A Prensa Parafuso mostrou-se vantajosa quanto a diminuição do tempo e aumento da capacidade de processamento de lodo, baixa exposição do operador a condições insalubres e diminuição da necessidade de mão de obra, mitigação da liberação de odores desagradáveis e proliferação de moscas de insetos.
14

Avaliação da força de compressão dos parafusos sem cabeça (HCS) - modelo experimental de fraturas do escafoide em ossos sintéticos / Evaluation of the compressive force of the headless compression screw (HCS) - experimental model of scaphoid fractures in synthetic bone

Filipe Jun Shimaoka 09 February 2017 (has links)
A força de compressão entre os fragmentos é um importante fator que interfere na consolidação das fraturas. O objetivo deste trabalho foi avaliar a eficácia de cada um dos parafusos sem cabeça de auto compressão com três diâmetros de rosca diferentes, empregados no tratamento das fraturas do escafoide. Utilizando um dispositivo de alumínio acoplado à uma máquina universal de ensaios equipada com uma célula de carga de 50 kgf. Foram utilizados dois blocos de espuma rígida de poliuretana de densidade 0,16 g/cc. Os testes foram realizados com os parafusos HCS da marca Synthes®, com diâmetros de 3,0 mm, 2,4 mm e 1,5 mm. Todos tinham 20 mm de comprimento. Os parafusos foram introduzidos utilizando os princípios da técnica AO, sendo o instrumental fornecido com os parafusos. Foram realizados com os parafusos supracitados fixações com inserção a 90º, 60º, 45º e 30º de inclinação em relação à superfície do bloco. Todos procedimentos foram repetidos por sete vezes, comparando-se os valores obtidos do pico da força de compressão (Força Max), da força de compressão após 20 segundos (Força T1) e da força de compressão após 300 segundos (Força T2). Para as fixações dos parafusos de 3.0 mm e 2.4 mm com 30º de inclinação não houve compressão, devido ao rompimento da superfície do bloco pela rosca da extremidade proximal dos parafusos. A Força Max do parafuso HCS de 3.0 mm foi maior do que a dos parafusos de 2.4 mm em todas as comparações. A relação entre as Força T2/Força T1 foram semelhante em todas as comparações, isto é, não apresentaram diferença estatística, e demostraram que a acomodação dos parafusos não foi relacionada ao diâmetro da rosca dos parafusos. Concluímos que a força de compressão entre os fragmentos foi maior quando o diâmetro da rosca do parafuso também foi maior, independente da posição da inserção em relação à fratura / The interfragmentary compression force is an important factor for fracture healing. The aim of this study was to evaluate the effectiveness of each three different diameters headless compression screw, used for the treatment of scaphoid fractures. It was used an aluminum device coupled to a universal testing machine equipped with a load cell of 50 kgf. Two rigid foam blocks made of polyurethane with density of 0.16 g/cc. The tests were performed with the HCS Synthes® with 20 mm length 3.0 mm, 2.4 mm and 1.5 mm in diameter. The screws were inserted using the AO technique and instrumental provided with screws. They were performed with the above screw with 90º, 60º, 45º and 30º tilt with the block and repeated seven times and comparing the results obtained from the peak compression force (Max Force) to compression force after 20 seconds (T1 Force) and compression force after 300 seconds (T2 force). For the fixations of 3.0 mm and 2.4 mm screws with 30° tilt no compression were reached, as the proximal threads of the screws broke the surface of the block. Max Force for HCS 3.0 mm was higher than the 2.4 mm screws in all comparisons. The relationship T2 Force / T1 Force was similar in all comparisons, showing no statistical difference, proving that the accommodation of the screws is not related to the threads diameter of the screws. It was concluded in this work that there was a reduction of interfragmentary compressive force by reducing the threads diameter of the screws, regardless of the position placed over the fracture surface
15

Distribuição de tensões de parafusos do sistema de fixação vertebral submetidos a arrancamento utilizando fotoelasticidade de transmissão plana / Stresses distributions of screws of the vertebral fixation systems submitted to pullout strength using plane transmission photoelasticity.

Sarah Fakher Fakhouri 12 February 2008 (has links)
O tratamento de deformidade espinhal, doença degenerativa, trauma, e tumores da coluna vertebral exigem freqüentemente a realização da fixação interna. O surgimento dos parafusos pediculares possibilitou a realização da instrumentação segmentar da coluna mais estável, tornando-se atualmente procedimento padrão para realização das cirurgias de correção, estabilização de deformidade e instabilidade da coluna em patologias torácicas, lombares e sacrais. O segmento vertebral mais favorável para a implantação do parafuso é a região lombar, devido ao maior diâmetro dos pedículos. A fotoelasticidade tem sido utilizada em estudos científicos a fim de determinar a distribuição de tensões/deformações em sistemas estruturais, pois permite uma análise qualitativa e quantitativa do estado de tensão, através da observação de efeitos óticos. Neste trabalho foi utilizada esta técnica para determinar e analisar as tensões internas de modelos fotoelásticos sob influência de parafusos pediculares tipo USS1, quando submetidos a esforços de arrancamento. Para realização das análises fotoelásticas foram confeccionados 12 modelos divididos em três grupos, contendo em cada 4 modelos fotoelásticos. O primeiro grupo, G1, inclui o parafuso com diâmetro externo de 5 mm, o segundo, G2, o parafuso com diâmetro externo de 6 mm e o terceiro, G3, o parafuso com diâmetro externo de 7 mm. A simulação foi feita utilizando cargas de 0,75 e 1,5 Kgf. As ordens de franjas foram avaliadas em torno dos parafusos, utilizando o método de compensação de Tardy. Em todos os modelos analisados foram determinadas as tensões cisalhantes. Os resultados mostraram que para a carga de 0,75 Kgf, a tensão cisalhante máxima no parafuso de 5 mm foi maior que no de 6 mm, que foi maior que no de 7 mm. Com a carga de 1,5 Kgf houve igualdade nos três diâmetros externos de parafusos, e comparando estas duas cargas prevaleceu o último resultado. De acordo com as análises realizadas nos doze modelos, observou-se que o local de maior tensão é no pico das cristas, principalmente próxima a ponta dos parafusos. Sendo assim, esta técnica é bastante eficiente, pois, através da análise quantitativa e qualitativa foi possível comparar os parafusos de fixação vertebral, verificando qual é o mais suscetível ao arrancamento. / The treatment of spinal deformities, degenerative disease, injuries and tumors on the vertebral column often demand the accomplishment of the internal fixation. The pedicular screws arising enabled the accomplishment of column segmental instrumentation more stable and became a standard procedure in accomplishing surgeries of correction, deformities stabilization and column instability in thoracic, lumbar and sacral pathologies. The best vertebral segment for the screw implantation is the lumbar area due to a larger diameter of the pedicles. The photoelasticity has been used in scientific studies in order to determine the stress/strain distribution in structural systems, because it allows a qualitative and quantitative analysis of the state of stress, through the observation of optical effects. In this work was used this technique to determine and analyze the internal stress of the photoelastic models under the influence of pedicular screws type USS1 submitted to pullout strength. In order to accomplish the photoelastic analysis 12 models divided in 3 groups were made. Each of them contained 4 photoelastic models. The first group, G1, was composed by the screw of 5 mm of external diameter, the second, G2, was composed by the screw of 6 mm external diameter and the third, G3, by a screw of 7 mm external diameter. The simulation was performed using loads of 0.75 Kgf and 1.5 Kgf. The fringe orders were evaluated around the screws using the Tardy compensation method. In all the models analyzed were calculated the shear stress. The results showed that using the load of 0.75 Kgf the shear stress in the 5 mm screw was bigger than in the 6 mm screw, which was bigger than in the 7mm screw. With a load of 1.5 Kgf there was equality among the three external diameter screws and comparing these two last loads, the last result prevailed. According to the analysis realized in the 12 models, we observed that the place of highest stress is at the peak of the crests mainly at the tips of the screws. Concluding, this technique is efficient enough because through the quantitative and qualitative analysis it was possible to compare the vertebral fixation screws, verifying witch one is more susceptible to pullout.
16

Estudo mecânico "in vitro" da resistência a forças axiais do parafuso canulado de 3,5mm de diâmetro, em comparação ao parafuso convencional de mesmo diâmetro, em fraturas de cabeça e colo femoral / Mechanical study "in vitro" of the resistance of axial forces of 3.5mm cannulated screws in comparison with conventional screws of the same diameter, in head and femoral neck fractures

Daniel Castelo Branco Baccarin 28 June 2006 (has links)
Em razão da complexidade da osteossíntese nas regiões de colo e cabeça femorais, aliado à dificuldade da boa redução e fixação da fratura, objetivou-se estudar comparativamente os efeitos das cargas com forças axiais nos conjuntos osso-parafuso convencional e osso-parafuso canulado. O parafuso canulado possui eficiente capacidade compressiva e por possuir uma cânula central é capaz de simplificar a técnica cirúrgica se comparado aos parafusos ósseos convencionais. Foram utilizados dois parafusos dispostos paralelamente, inseridos da porção lateral do fêmur, abaixo do trocânter maior, em direção à cabeça femoral em 14 fêmures de cães acima de 20 kilos de peso, subdivididos em 2 grupos de 7 fêmures com parafusos convencionais e 7 fêmures com parafusos canulados , sem sinais macroscópicos ou radiográficos de moléstias ósseas. Os resultados obtidos mostraram que não houve diferenças estatísticas na força máxima e na rigidez nos dois grupos, e em todos os ensaios, os implantes não sofreram deformação, portanto conclui-se que as resistências dos parafusos convencional e canulado, utilizados na osteossíntese de fraturas de cabeça e colo de fêmur, são semelhantes. / Because of the complexity of osteosynthesis of femoral head and neck fractures and the difficulty of good reduction and fixation of the fractures, we studied comparatively the effects of load and axial forces of bone-conventional screws and bone-cannulated screws. The cannulated screw presents efficient compressive capacity and it presents a central cannula capable of simplifying the surgical technique if compared to conventional bone screws. We used two screws placed parallel, inserted in the lateral aspect of the femur, beneath the greater trocanter, directed to the femoral head, in fourteen femurs of dogs over 20Kg, subdivided in two groups of seven femurs each, the first with conventional screws and the second with cannulated screws, with no macroscopic or radiographic signs of bone diseases. The results didn´t show any statistical differences in maximum strength and rigidity of both groups and the implants didn´t suffer deformities in any essays, therefore we conclude that the resistances of conventional and cannulated screws, used in of femoral heads and necks fracture repairs, are similar.
17

Ferrita delta em parafusos tratados termicamente: caracterização e consequências / Delta ferrite in heat treated bolts: characterization and consequences

Robson Silva Bussoloti 29 July 2014 (has links)
Nos processos de fabricação de parafusos, a fosfatização é necessária para servir de ancoradouro aos lubrificantes, e outros redutores de atrito, por facilitarem o processo de deformação a frio. No entanto, antes do início do tratamento térmico de têmpera e revenimento, é importante que o banho de desfosfatização seja eficiente para impedir que, durante a austenitização, o fósforo residual presente na superfície do parafuso se difunda para o aço e forme uma fase frágil, rica em fósforo, denominada ferrita delta (&#948). Acredita-se que esta fase, uma vez presente, promove não apenas a diminuição da vida em fadiga mas, também, a fragilização do parafuso. Neste sentido, o presente trabalho objetivou comprovar a influência negativa dessa fase, devidamente caracterizada por MEV, EDS e análise fractográfica, quanto ao desempenho à fadiga, através da comparação das curvas S-N em corpos de prova com e sem ferrita &#948. Os resultados obtidos claramente evidenciaram que a presença da fase &#948 promoveu uma redução de até 40% na vida em fadiga. / In the process of manufacturing bolts, a coat phosphating is required to serve as anchorage for lubricants and other friction-reducer, facilitating the cold forming process. However, before the beginning heat treatment of quenching and tempering, it is important that the alkaline bath for cleaning be efficient in order to prevent that during austenitizing, the residual phosphorus spread on the steel surface and forms a brittle phase, rich in phosphorus, called delta ferrite (&#948). In the presence of this phase, is credited with a decrease in fatigue life of the bolt and embrittlement. The intention in this work was to show the negative influence of this phase on fatigue performance, comparing the S-N curves for specimens with and without ferrite &#948. Trials have shown a reduction of up to 40% in life fatigue. The ferrite &#948 was characterized by SEM, EDS and also performed fractographic analysis.
18

Ensaios mecânicos e estudo histológico da interface dos implantes vertebrais / Mechanical and histological studies of the vertebral screw interface

Vendrame, José Roberto Benites 26 September 2006 (has links)
A cirurgia da coluna vertebral tem se desenvolvido muito nos últimos anos em decorrência da evolução dos sistemas de fixação. O comportamento da interface do parafuso com o osso continua sendo um aspecto não muito dominado. Como o parafuso é a âncora de sustentação, o trabalho procura investigar as técnicas de introdução do parafuso pedicular. Para atingir esse objetivo desenvolvemos o trabalho por meio de estudo com ensaios mecânicos de arrancamento e estudo histológico. Dois tipos de parafusos pediculares foram utilizados: parafuso pedicular do sistema USIS (Ulrich) e parafuso pedicular do sistema USS (Synthes). Os ensaios de arrancamento foram realizados em corpos de prova de madeira e poliuretano. O estudo histológico foi realizado em vértebras lombares de cadáver humano. No estudo envolvendo o parafuso USIS, foram testados os seguintes parâmetros: orifícios feitos com sonda e orifícios feitos com broca, todos do mesmo diâmetro do diâmetro interno do parafuso. Também foi testado o efeito do macheamento em relação ao não macheamento, nos orifícios feitos com broca. No estudo com os parafusos USS foram testados o efeito do diâmetro do orifício piloto tanto no estudo histológico como no arrancamento. No arrancamento destes parafusos também foi testado o efeito do tipo de orifício feito com sonda e com broca. O trabalho foi dividido em etapas: Primeira etapa foi o estudo de arrancamento do parafuso USIS; segunda etapa, estudo histológico de vértebra instrumentada com parafuso USIS, esta parte do trabalho foi constituída por análise de microscopia de luz e microscopia eletrônica de varredura; terceira etapa foi o arrancamento do parafuso USS; e quarta etapa foi o estudo histológico de vértebra instrumentada com parafuso USS. Os resultados da primeira etapa demonstraram que sonda teve efeito melhor do que broca, porque o resultado dos ensaios de arrancamento nos orifícios feitos com sondas teve maior força de arrancamento do que nos orifícios feitos por brocas. Na segunda etapa, análise histológica, verificou-se que os orifícios feitos por sonda apresentaram-se menores e com menor índice de fragmentação ao redor dos orifícios. Esses feitos tiveram diferença estatística significante, tanto na primeira, quanto na segunda etapa. Com relação ao macheamento não foi constatada diferença entre o não macheamento, em nenhuma das duas etapas. Na terceira etapa foi observado que, quando o orifício piloto ultrapassa o diâmetro interno do parafuso, ocorre tendência de queda na força de arrancamento de modo significativo, enquanto que orifício menor que o orifício piloto não tende a causar muita diferença na força de arrancamento em relação ao orifício correspondente ao diâmetro interno do parafuso. Também foi observado que o orifício feito com sonda oferece melhor força de ancoragem do que orifício feito com broca. Na quarta etapa foi constatado que quanto menor a broca para abrir o orifício piloto, menor o diâmetro do orifício, e não houve diferença significativa quanto ao índice de fragmentação ao redor do orifício entre os diferentes tamanhos de broca. Como conclusão pode-se dizer que sonda é melhor para se fazer o orifício piloto, uma vez que alarga menos o orifício, lesa menos as trabéculas ao redor do orifício e proporciona maior força de ancoragem do que broca. Também se pode concluir que o instrumental de menor diâmetro para abertura do orifício piloto é melhor, e o ponto crítico seria o diâmetro interno do parafuso. Não se deve fazer orifício piloto com instrumento de diâmetro maior que o diâmetro interno do parafuso. Não se constatou vantagem em relação ao fato de realizar ou deixar de realizar o macheamento. / Spine surgery has developed a lot in the last years because of the evolution of the fixation system. The behavior of a screw in the bone is still unknown in many ways. Because the screw is the anchor of sustentation, this work tries to find the answers involving the pedicle screw fixation. To reach this objective we developed this work based on mechanical and histological studies. Two kinds of pedicle screws were used: pedicle screw of the USIS (Ulrich) and pedicle screw of the USS system (Synthes). The pullout tests were made in wood and polyurethane. The histological study was done in lumbar vertebra of humans. In the study about the USIS screw, the follow parameters were tested: hole done with probe and hole done with drill, all of the same inner diameter of the screw. The effect of tapping and not tapping the hole done with drill was tested. In the USS screw study, the effect of the diameter pilot hole in the pullout tests and its historical analysis was seen. In the pullout tests of these screws, both kind of holes done with probes and a drill were tested. The work was divided into stages; first stage was the study of the pullout of the USIS screw; second stage was two studies, a light-microscopic one and a sweeping-electronic-microscope one of the slides of the instrumented vertebra with USIS screws; third stage was the study of the USS screws pullout comparing the relationship between the diameter of the holes and the inner diameter of the screw together with the type of hole (drill and probe); fourth stage was light-microscopic histological study of the instrumented vertebras which had had USIS screws. Results of the first stage showed that probes were more efficient than drills because the mechanical tests of pullouts from probe-made-holes showed the need of the use of a stronger force. In the second stage, a light-microscopic analysis showed that probe-made-holes had a lesser minimum diameter and a lower index of fragmentation than drill-made holes. With relation to the tapping, there was no difference between the holes. Under electronic microscope sweeping, it was seen that probes betters compact the bone around the screw. In the third stage, it was seen that when 9 the pilot orifice was greater than the screws internal diameter a significantly lower force was needed for pullout, while when the pilot orifice was smaller it did not significantly increase the force needed. It was also seen that probe-made-holes had a better anchorage than the drill-made-holes. In the fourth stage, the histological analysis of the slides done with light-microscopy showed that the smaller the diameter of the drill the smaller minimum diameter; there was no significant difference between fragmentation indexes. Conclusion: Probes are better than drills to make a pilot hole because they cause less damage to the surrounding bone and give a stronger anchorage for the screw; the smaller the instrument used to make the pilot hole, better will be the strength of the screws anchorage; the critical point which the hole must not exceed is the internal diameter of the screw. Tapping, or not, makes no difference to the anchorage.
19

Avaliação do destorque de dois tipos de parafusos fixadores do munhão e da resistência à tração de coroas cimentadas sobre munhões com diferentes características superficiais

Toledo, Fabiane Lopes 02 September 2011 (has links)
Problemas freqüentes na prótese sobre implante são o afrouxamento do parafuso que une o munhão ao implante e a soltura da prótese cimentada. Assim, foi estudada a manutenção da força de torque, promovida por 2 diferentes parafusos fixadores de munhão, e a resistência à remoção por tração de coroas de NiCr, cimentadas ou re-cimentadas com fosfato de zinco sobre munhões com diferentes características. Numa primeira fase, foram utilizados 20 conjuntos implante/munhão/parafuso (NEODENT), constituídos de liga de Ti, nos quais existiam 10 parafusos comuns e 10 revestidos com carbono (Neotorque). A força de torque de 32 N era aplicada com um torquímetro analógico de precisão (TOHNICHI) e, para a aplicação cíclica de carga de compressão axial, foi utilizada uma máquina eletro-mecânica de fadiga, com carga de 200 N e freqüência de 2 hertz, durante 500.000 ciclos. Na segunda fase, foram usados 30 conjuntos (implante/munhão/parafuso e respectivas coroas), onde existiam apenas parafusos comuns, porém com munhões de diferentes tamanhos e aspectos superficiais: o munhão universal (MU), o personalizado original (MPO) e o personalizado irradiado (MPI). As coroas destes 2 últimos grupos já haviam sido cimentadas e tracionadas, num trabalho anterior. Todas as coroas foram agora cimentadas com fosfato de zinco e submetidas (7 dias depois) a ensaios de tração, em uma máquina universal de ensaios regulada na velocidade de 0,5 mm/min. Nas condições deste trabalho, foi possível concluir que ambos os parafusos analisados (comum e Neotorque) apresentaram comportamento semelhante, na manutenção da força de torque promovida, e que a resistência à remoção por tração de coroas, cimentadas pela primeira vez, com o munhão universal (MU), foi a menor de todas (227,83 N.cm); para os caso das recimentações, com o munhão personalizado de textura original, esta resistência apresentou valor intermediário (448,37 N.cm), tendo sido a maior de todas (1.570,76 N.cm) aquela apresentada pelo munhão personalizado que sofreu irradiação por LASER. / Frequent problems in implant prosthodontics are loosening the screw that joins the abutment to implant and the releasing of the cemented prosthesis. Thus, it was studied both the torque force mantenaince promoted by two different screws as the resistance to removal by traction of NiCr crowns, cemented or re-cemented with zinc phosphate over abutments with different characteristics. In a first phase, it were used 20 Ti alloy-made sets (composed by Neodent implant / abutment / screw), in which there were 10 slotted screws carbon-coated (Neotorque). The torque force of 32 N was applied with an analogical torque wrench (TOHNICHI) and the cyclic axial compression load with a fatigue electro-mechanical machine, with a load of 200 N and frequency of 2 Hz, over 500,000 cycles. In the second phase, it was used 30 other sets (composed by implant / abutment / screw and their crowns) where there were only common screws, but with sleeves of different size and superficial aspects: the universal abutment (MU), that personalizable with original texture (MPO) and the personalizable with a LASER treatment (MPI). Crowns of these two latter groups had already been cemented and pulled in a previous work. All crowns were here cemented with zinc phosphate and submitted (7 days later) to tensile tests in an universal testing machine set at a speed of 0.5 mm / min. In the conditions of the present work, it was concluded that both analyzed screws (common and Neotorque) behaved similarly, maintaining the torque force promoted, and that resistance to removal by traction of crowns cemented by first time with the universal abutment (MU) was the lowest of all (227.83 N.cm); for recementations, personal abutment with original texture had intermediate values resistance (448.37 N.cm), being the largest of all (1570.76 N.cm) that presented by the abutment modified by LASER irradiation.
20

Avaliação mecânica da estabilidade de parafusos protéticos em diferentes sistemas de retenção pilar/implante / Mechanical evaluation of the prosthetic screw stability from different implant/abutment retention systems

Bernardes, Sérgio Rocha 10 October 2008 (has links)
Foi analisada a variação da pré-carga de parafusos durante os cinco primeiros minutos depois de cada uma de cinco seqüências aperto e desaperto de parafusos de implantes dentários com diferentes sistemas de retenção pilar/implante. Extensômetros foram colados no terço cervical de implantes com interface de hexágono externo, hexágono interno e cone Morse. Um procedimento controlado de aperto e desaperto dos parafusos permitiu o arquivo dos valores de torque reverso, em relação ao aperto, e o campo de tensões gerado sobre o terço cervical dos implantes resultante da pré-carga do parafuso para cada uma das seqüências. Foram estudadas 30 amostras de implantes/pilares, dividas em oito grupos: implantes de hexágono externo com intermediário Munhão Universal e parafusos de titânio (Neodent, Curitiba, Brasil) apertados a 32 N.cm (EH.Ti.32); hexágono externo, Munhão Universal, parafuso de titânio recoberto por DLC, 32 N.cm (EH.dlc.32); hexágono interno, Munhão Universal, parafuso de titânio, 20 N.cm (IH.Ti.20); cone Morse, Munhão Universal peça única, 20 N.cm (MT.OP.20); cone Morse, Munhão Universal peça única, 32 N.cm (MT.OP.32); Cone Morse, Munhão Universal parafuso passante, 10 N.cm (MT.TS.10); no sétimo grupo foram usados as mesmas amostras do grupo MT.TS.10 a 10 N.cm, porém o desaperto foi realizado pelo intermediário (MT.TS.10.A); para o último grupo foram usados as mesmas amostras do grupo MT.TS.10 e MT.TS.10.A, porém o aperto dos parafusos foi de 15 N.cm e o desaperto também se deu pelo o intermediário (MT.TS.15.A). Os valores médios e desvio padrão (dp) de pré-carga encontrados para todas as seqüências de cada grupo foram de: EH.Ti.32 (27,75; dp 7,70); EH.dlc.32 (40,17; dp 10,16); IH.Ti.20 (219,61; dp 75,47); MT.OP.20 (129,19; dp 116,71); MT.OP.32 (137,97; dp 47,53); MT.TS.10 (39,55; dp 13,96); MT.TS.10.A (126,72; dp 44,05); MT.TS.15.A (194,41; 68,48). Entre os diferentes sistemas de retenção pilar/implante estudados, pode-se concluir que: existem relações únicas entre o valor de torque aplicado no parafuso e a pré-carga gerada sobre o terço cervical do implante, essas são diretamente influenciados pelo desenho da interface pilar/implante, tipo de parafuso de retenção e valor de torque aplicado; não foi observada perda de pré-carga dos parafusos de pilares, nem perda de resistência à torção no sentido anti-rotacional dos parafusos depois de esperados 5 minutos em 5 seqüências de aperto/desaperto. / The preload screw variation for the first five minutes after each one of five torque/untorque sequences from different implant/abutment retention systems was evaluated. Strain gauges were attached over the cervical third of external hex, internal hex and Morse taper implants. A controlled torque/untorque procedure allowed the record from the preload and untorque values of the samples in each one of the sequences. Thirty implant/abutment samples, divided in eight groups were studied: external hex implants with Universal post and titanium screws (Neodent, Curitiba, Brazil) screwed to 32 N.cm (EH.Ti.32); external hex, Universal post, DLC covered screw, 32 N.cm (EH.dlc.32); internal hex, Universal post, titanium screw, 20 N.cm (IH.Ti.20); Morse taper, single piece Universal post, 20 N.cm (MT.OP.20); Morse taper, single piece Universal post, 32 N.cm (MT.OP.32); Morse taper, Universal post trespassing screw, 10 N.cm (MT.TS.10); the same samples from the MT.TS.10 group were used for the seventh group, screwed to 10 N.cm, but the untorque was performed by the abutment (MT.TS.10.A); the same samples used with the MT.TS.10 and the MT.TS.10.A were used for the last group, but the screws were tightened to 15 N.cm and the untorque remained by the abutment (MT.TS.15.A). The mean and the stardad deviation (DP) found for the preloss in all the five sequences were of: EH.Ti.32 (27.75; SD 7.70); EH.dlc.32 (40.17; SD 10.16); IH.Ti.20 (219.61; SD 75.47); MT.OP.20 (129.19; SD 116.71); MT.OP.32 (137.97; SD 47.53); MT.TS.10 (39.55; SD 13.96); MT.TS.10.A (126.72; SD 44.05); MT.TS.15.A (194.41; SD 68.48). For the retention systems studied, it could be concluded that: there are single relations between screw untorque and preload over the implant cervical third, these are directely influenced by the implant/abutment interface design, screw type and torque value; there were not found post screw preload loss, neither torque resistance at the anti-rotational direction from the screws after the first five minutes in five torque/untorque sequences.