• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 43
  • Tagged with
  • 43
  • 34
  • 16
  • 12
  • 11
  • 10
  • 7
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

"Estudo comparativo do afrouxamento de diferentes parafusos de fixação de abutment em implantes de hexágono externo e interno, após o ensaio de ciclagem mecânica" / Comparative study of screw loosening for different abutment screw in external and internal hexagonal implant system after cyclic loading

Nakamura, Lilian Hitomi 28 September 2005 (has links)
A proposta deste estudo foi avaliar o torque de afrouxamento de três tipos de parafusos de fixação de abutment. Foram formados seis grupos: grupos HE-TiS e HE-TiNS (implante e abutment de hexágono externo, parafuso de fixação de titânio, submetidos e não-submetidos ao ensaio), grupos HE-AuS e HE-Au NS (implante e abutment de hexágono externo, parafuso de fixação de ouro, submetidos e não-submetidos ao ensaio) e grupos HI-TiS e HI-TiNS (implante e abutment de hexágono interno, parafuso de fixação de titânio, submetidos e não-submetidos ao ensaio). Para a realização da ciclagem mecânica, foi desenvolvida uma máquina de ensaio cuja carga máxima aplicada foi de 120 N em sentido axial, com deslizamento de 0,3mm sobre a superfície oclusal da coroa e força de atrito de 28 N a uma freqüência de 60 ciclos por minuto , durante 500.000 ciclos. O torque de apertamento inicial dos parafusos de fixação foi de 32 Ncm e o de afrouxamento mensurado a cada 100.000 ciclos nos grupos submetidos ao ensaio de ciclagem mecânica e a cada 24 horas após o torque de apertamento nos grupos não-submetidos ao ensaio. Dentro das condições experimentais deste estudo, os resultados obtidos sugerem que: os valores de destorque dos parafusos de fixação foram menores em todos os grupos submetidos ao ensaio; o destorque foi estatisticamente menor para os parafusos de titânio quando comparados os grupos HE-TiS (15,56±1,38 Ncm – 48%) / HE-AuS (18,15±1,85 Ncm – 56%) e os grupos HE-TiNS (23,76±1,59 Ncm – 74%) / HE-AuNS (27,06±1,23 Ncm – 84,5%); o destorque dos parafusos de titânio também foi estatisticamente menor quando utilizados nos grupos HE-TiS (15,56±1,38 Ncm – 48%), comparados aos grupos HI-TiS (18,56±1,14 Ncm – 58%). / The purpose of this study was to evaluate the abutment screw loosening when either submitted or not to cyclic loading. Six groups were composed: HE-TiS and HE-TiNS (external hexagonal implant and abutment, titanium abutment screw, submitted and not subimitted to cyclic loading), HE-AuS and HE-Au NS (external hexagonal implant and abutment, gold abutment screw, submitted not submitted to ciclyc loading), HI-TiS and HI-TiNS (internal hexagonal implant and abutment, titanium abutment screw, submitted and not submitted to ciclyc loading). In order to perform the cyclic loading, it was developed a device wich applied the maximum load of 120 N in the axial direction, with a slip of 0,3 mm on the crown oclusal surface with friction force of 28 N. The frequency was 60 cycles per minute for a duty of 500,000 cycles. The abutment screw was tightened to 32 Ncm and the loosening torque was measured after every 100,000 cycles in the submitted groups and every 24 hours after the tightening torque in the not-submitted groups. Within the limitations of this study, the results suggest that the loosening torque values were statistically significant lower in all groups submitted to the cyclic loading; the loosening torque was statiscally lower for titanium screws when compared HE-TiS (15,56±1,38 Ncm – 48%) / HE-AuS (18,15±1,85 Ncm – 56%) groups and HE-TiNS (23,76±1,59 Ncm – 74%) / HE-AuNS (27,06±1,23 Ncm – 84,5%) groups; the loosenig torque was also lower for the titanium screws when used to in the groups HE-TiS (15,56±1,38 Ncm – 48%) compared to HI-TiS (18,56±1,14 Ncm – 58%).
22

Modelo de comportamento termodinâmico de uma bomba multifásica do tipo duplo parafuso. / Thermodynamic model of a twin-screw multiphase pump.

Celso Yukio Nakashima 04 December 2000 (has links)
Esse trabalho apresenta um modelo termodinâmico de uma bomba multifásica do tipo duplo parafuso. Para uma dada condição de operação, o modelo calcula a potência consumida, as condições do fluido na descarga e o perfil de pressão ao longo da bomba. Ao invés de simular diretamente o escoamento dentro da bomba, simulou-se os processos que ocorrem dentro das suas câmaras. Para tanto, dividiu-se o processo de bombeamento multifásico em uma seqüência de processos simples, facilitando-se a construção do modelo no simulador de processos Hysys.Process v2.1. Os resultados de potência e temperatura de descarga obtidos com a simulação mostram uma boa concordância com valores experimentais, principalmente para FVG’s baixos. Para FVG’s elevados, o modelo passa a superestimar a potência consumida indicando que as fendas, nesses casos, já não se encontram totalmente preenchidas com líqüido. Dos resultados obtidos para o refluxo, conclui-se que, das equações sugeridas na literatura, aquelas para escoamento turbulento liso são mais adequadas para os números de Reynolds envolvidos. O perfil de pressão e a vazão de refluxo quando o escoamento é multifásico aproxima-se qualitativamente das medições experimentais. Estudou-se a influência de diversos parâmetros na eficiência exergética da bomba. Os resultados mostram que a otimização da eficiência depende das condições de operação da bomba: FVG, tipo de líqüido, diferença de pressão, entre outros. / The goal of this project was to develop a thermodynamic model of a twin-screw multiphase pump. With given operation conditions the model can determine the absorbed power, discharge conditions and the pressure profile along the screw. An alternative approach was suggested to overcome the complex flow problem and the processes inside the pump were simulated instead of direct simulation of the flow. For this purpose, the multiphase pumping process was divided in a sequence of simple processes so the model could be developed in an easier way. The power and temperature values calculated by the model are in good agreement with experimental data, mainly when the gas fraction is low. With higher gas fractions, the model overestimates the absorbed power indicating that screw gaps are not completely filled with liquid anymore. Concerning about the backflow rate, the results show that the equations for turbulent flow in smooth ducts fits better the Reynolds number range in the gaps. The pressure profile and backflow rate for multiphase flow agree qualitatively with experimental results. The influence of several parameters in the exergetic eficiency of the pump were analysed and results show that the efficiency optimization depends on pump operation conditions: gas fraction, liquid type, pressure difference and others.
23

Modelo de comportamento termodinâmico de uma bomba multifásica do tipo duplo parafuso. / Thermodynamic model of a twin-screw multiphase pump.

Nakashima, Celso Yukio 04 December 2000 (has links)
Esse trabalho apresenta um modelo termodinâmico de uma bomba multifásica do tipo duplo parafuso. Para uma dada condição de operação, o modelo calcula a potência consumida, as condições do fluido na descarga e o perfil de pressão ao longo da bomba. Ao invés de simular diretamente o escoamento dentro da bomba, simulou-se os processos que ocorrem dentro das suas câmaras. Para tanto, dividiu-se o processo de bombeamento multifásico em uma seqüência de processos simples, facilitando-se a construção do modelo no simulador de processos Hysys.Process v2.1. Os resultados de potência e temperatura de descarga obtidos com a simulação mostram uma boa concordância com valores experimentais, principalmente para FVG’s baixos. Para FVG’s elevados, o modelo passa a superestimar a potência consumida indicando que as fendas, nesses casos, já não se encontram totalmente preenchidas com líqüido. Dos resultados obtidos para o refluxo, conclui-se que, das equações sugeridas na literatura, aquelas para escoamento turbulento liso são mais adequadas para os números de Reynolds envolvidos. O perfil de pressão e a vazão de refluxo quando o escoamento é multifásico aproxima-se qualitativamente das medições experimentais. Estudou-se a influência de diversos parâmetros na eficiência exergética da bomba. Os resultados mostram que a otimização da eficiência depende das condições de operação da bomba: FVG, tipo de líqüido, diferença de pressão, entre outros. / The goal of this project was to develop a thermodynamic model of a twin-screw multiphase pump. With given operation conditions the model can determine the absorbed power, discharge conditions and the pressure profile along the screw. An alternative approach was suggested to overcome the complex flow problem and the processes inside the pump were simulated instead of direct simulation of the flow. For this purpose, the multiphase pumping process was divided in a sequence of simple processes so the model could be developed in an easier way. The power and temperature values calculated by the model are in good agreement with experimental data, mainly when the gas fraction is low. With higher gas fractions, the model overestimates the absorbed power indicating that screw gaps are not completely filled with liquid anymore. Concerning about the backflow rate, the results show that the equations for turbulent flow in smooth ducts fits better the Reynolds number range in the gaps. The pressure profile and backflow rate for multiphase flow agree qualitatively with experimental results. The influence of several parameters in the exergetic eficiency of the pump were analysed and results show that the efficiency optimization depends on pump operation conditions: gas fraction, liquid type, pressure difference and others.
24

Estudo da Participação do Osso Cortical e Esponjoso na Fixação de Implante Pedicular na Coluna Lombar. / Mechanical and histological studies of the vertebral screw interface

Vendrame, José Roberto Benites 28 April 2000 (has links)
Foi realizado estudo experimental com a finalidade de avaliar a participação do osso cortical e osso esponjoso dos pedículos vertebrais, na fixação dos parafusos pediculares. Foram utilizados 10 segmentos de coluna lombar de adultos, retirados durante autópsia. O diâmetro dos pedículos das vértebras de L1 a L5 foram avaliados, considerando o diâmetro total e o diâmetyro do osso esponjoso, tendo sido realizadas essas medidas por meio de tomografia computadorizada e medida direta. Os segmentos da coluna vertebral foram divididos em dois grupos para o estudo, sendo que cada grupo era formado por 5 conjuntos de segmentos da coluna lombar. No primeiro grupo a perfuração era realizada segundo os pontos de orientação utilizados nos procedimentos cirúrgicos ( faceta articular e processo transverso). No segundo grupo foi realizado corte transversal na porção média do pedículo, de modo que a perfuração e introdução dos parafusos no seu interior foram efetuados sob visão diereta. Após a perfuração dos pedículos utilizando-se broca de 3 mm, os parafusos eram introduzidos no interior do pedículo vertebral em ordem crescente de seus diâmetros, até que fosse observada alteração estrutural do pedículo, que eram avaliados por meio de medidas sucessivas, utilizando-se paquímetro e observação direta. Foram utilizados parafusos com diâmetro que variou de 3 a 12,5 mm, com progressão de 0,5 mm. Quando o diâmetro do parafuso excedia a resistência estrutural do pedículo, duas lesões foram observadas, a deformação plástica e o rompimento. No grupo I houve um número maior de deformação plástica, mas pelos cálculos estatísticos não houve diferença significativa entre os grupos. Os diâmetro tomográficos obtidos pela medida tomográfica e medida direta apresentaram-se diferentes e sem correlação entre si. No grupo II, como os parafuos foram introduzidos de modo mais centralizado, houve maior número de parafusos com diâmetro maior que o diâmetro do osso esponjoso, mas também não apresentou diferença entre os grupos, segundo avaliações estatísticas. Análise dos valores do diâmetro pedicular, diâmetro do osso esponjoso e do parafuso de maior diâmetro introduzido sem lesar o pedículo permitiu observar que a camada de osso cortical do pedículo foi pouco ocupada pelo parafuso em ambos os grupos. O valor médio da porcentagem do diâmetro do pedículo ocupado pelo parafuso no grupo I foi de 70,7% e no grupo II 75,34%. Foi observado que os parafusos, de um modo geral, apresentaram ancoragem principalmente na porção de osso esponjoso do pedículo vertebral, tendo sido pequena a porcentagem de osso cortical do pedículo vertebral utilizado para a sua ancoragem. / Spine surgery has developed a lot in the last years because of the evolution of the fixation system. The behavior of a screw in the bone is still unknown in many ways. Because the screw is the anchor of sustentation, this work tries to find the answers involving the pedicle screw fixation. To reach this objective we developed this work based on mechanical and histological studies. Two kinds of pedicle screws were used: pedicle screw of the USIS (Ulrich) and pedicle screw of the USS system (Synthes). The pullout tests were made in wood and polyurethane. The histological study was done in lumbar vertebra of humans. In the study about the USIS screw, the follow parameters were tested: hole done with probe and hole done with drill, all of the same inner diameter of the screw. The effect of tapping and not tapping the hole done with drill was tested. In the USS screw study, the effect of the diameter pilot hole in the pullout tests and its historical analysis was seen. In the pullout tests of these screws, both kind of holes done with probes and a drill were tested. The work was divided into stages; first stage was the study of the pullout of the USIS screw; second stage was two studies, a light-microscopic one and a sweeping-electronic-microscope one of the slides of the instrumented vertebra with USIS screws; third stage was the study of the USS screws pullout comparing the relationship between the diameter of the holes and the inner diameter of the screw together with the type of hole (drill and probe); fourth stage was light-microscopic histological study of the instrumented vertebras which had had USIS screws. Results of the first stage showed that probes were more efficient than drills because the mechanical tests of pullouts from probe-made-holes showed the need of the use of a stronger force. In the second stage, a light-microscopic analysis showed that probe-made-holes had a lesser minimum diameter and a lower index of fragmentation than drill-made holes. With relation to the tapping, there was no difference between the holes. Under electronic microscope sweeping, it was seen that probes betters compact the bone around the screw. In the third stage, it was seen that when the pilot orifice was greater than the screws internal diameter a significantly lower force was needed for pullout, while when the pilot orifice was smaller it did not significantly increase the force needed. It was also seen that probe-made-holes had a better anchorage than the drill-made-holes. In the fourth stage, the histological analysis of the slides done with light-microscopy showed that the smaller the diameter of the drill the smaller minimum diameter; there was no significant difference between fragmentation indexes. Conclusion: Probes are better than drills to make a pilot hole because they cause less damage to the surrounding bone and give a stronger anchorage for the screw; the smaller the instrument used to make the pilot hole, better will be the strength of the screw\'s anchorage; the critical point which the hole must not exceed is the internal diameter of the screw. Tapping, or not, makes no difference to the anchorage.
25

Avaliação do destorque de dois tipos de parafusos fixadores do munhão e da resistência à tração de coroas cimentadas sobre munhões com diferentes características superficiais

Fabiane Lopes Toledo 02 September 2011 (has links)
Problemas freqüentes na prótese sobre implante são o afrouxamento do parafuso que une o munhão ao implante e a soltura da prótese cimentada. Assim, foi estudada a manutenção da força de torque, promovida por 2 diferentes parafusos fixadores de munhão, e a resistência à remoção por tração de coroas de NiCr, cimentadas ou re-cimentadas com fosfato de zinco sobre munhões com diferentes características. Numa primeira fase, foram utilizados 20 conjuntos implante/munhão/parafuso (NEODENT), constituídos de liga de Ti, nos quais existiam 10 parafusos comuns e 10 revestidos com carbono (Neotorque). A força de torque de 32 N era aplicada com um torquímetro analógico de precisão (TOHNICHI) e, para a aplicação cíclica de carga de compressão axial, foi utilizada uma máquina eletro-mecânica de fadiga, com carga de 200 N e freqüência de 2 hertz, durante 500.000 ciclos. Na segunda fase, foram usados 30 conjuntos (implante/munhão/parafuso e respectivas coroas), onde existiam apenas parafusos comuns, porém com munhões de diferentes tamanhos e aspectos superficiais: o munhão universal (MU), o personalizado original (MPO) e o personalizado irradiado (MPI). As coroas destes 2 últimos grupos já haviam sido cimentadas e tracionadas, num trabalho anterior. Todas as coroas foram agora cimentadas com fosfato de zinco e submetidas (7 dias depois) a ensaios de tração, em uma máquina universal de ensaios regulada na velocidade de 0,5 mm/min. Nas condições deste trabalho, foi possível concluir que ambos os parafusos analisados (comum e Neotorque) apresentaram comportamento semelhante, na manutenção da força de torque promovida, e que a resistência à remoção por tração de coroas, cimentadas pela primeira vez, com o munhão universal (MU), foi a menor de todas (227,83 N.cm); para os caso das recimentações, com o munhão personalizado de textura original, esta resistência apresentou valor intermediário (448,37 N.cm), tendo sido a maior de todas (1.570,76 N.cm) aquela apresentada pelo munhão personalizado que sofreu irradiação por LASER. / Frequent problems in implant prosthodontics are loosening the screw that joins the abutment to implant and the releasing of the cemented prosthesis. Thus, it was studied both the torque force mantenaince promoted by two different screws as the resistance to removal by traction of NiCr crowns, cemented or re-cemented with zinc phosphate over abutments with different characteristics. In a first phase, it were used 20 Ti alloy-made sets (composed by Neodent implant / abutment / screw), in which there were 10 slotted screws carbon-coated (Neotorque). The torque force of 32 N was applied with an analogical torque wrench (TOHNICHI) and the cyclic axial compression load with a fatigue electro-mechanical machine, with a load of 200 N and frequency of 2 Hz, over 500,000 cycles. In the second phase, it was used 30 other sets (composed by implant / abutment / screw and their crowns) where there were only common screws, but with sleeves of different size and superficial aspects: the universal abutment (MU), that personalizable with original texture (MPO) and the personalizable with a LASER treatment (MPI). Crowns of these two latter groups had already been cemented and pulled in a previous work. All crowns were here cemented with zinc phosphate and submitted (7 days later) to tensile tests in an universal testing machine set at a speed of 0.5 mm / min. In the conditions of the present work, it was concluded that both analyzed screws (common and Neotorque) behaved similarly, maintaining the torque force promoted, and that resistance to removal by traction of crowns cemented by first time with the universal abutment (MU) was the lowest of all (227.83 N.cm); for recementations, personal abutment with original texture had intermediate values resistance (448.37 N.cm), being the largest of all (1570.76 N.cm) that presented by the abutment modified by LASER irradiation.
26

"Estudo comparativo do afrouxamento de diferentes parafusos de fixação de abutment em implantes de hexágono externo e interno, após o ensaio de ciclagem mecânica" / Comparative study of screw loosening for different abutment screw in external and internal hexagonal implant system after cyclic loading

Lilian Hitomi Nakamura 28 September 2005 (has links)
A proposta deste estudo foi avaliar o torque de afrouxamento de três tipos de parafusos de fixação de abutment. Foram formados seis grupos: grupos HE-TiS e HE-TiNS (implante e abutment de hexágono externo, parafuso de fixação de titânio, submetidos e não-submetidos ao ensaio), grupos HE-AuS e HE-Au NS (implante e abutment de hexágono externo, parafuso de fixação de ouro, submetidos e não-submetidos ao ensaio) e grupos HI-TiS e HI-TiNS (implante e abutment de hexágono interno, parafuso de fixação de titânio, submetidos e não-submetidos ao ensaio). Para a realização da ciclagem mecânica, foi desenvolvida uma máquina de ensaio cuja carga máxima aplicada foi de 120 N em sentido axial, com deslizamento de 0,3mm sobre a superfície oclusal da coroa e força de atrito de 28 N a uma freqüência de 60 ciclos por minuto , durante 500.000 ciclos. O torque de apertamento inicial dos parafusos de fixação foi de 32 Ncm e o de afrouxamento mensurado a cada 100.000 ciclos nos grupos submetidos ao ensaio de ciclagem mecânica e a cada 24 horas após o torque de apertamento nos grupos não-submetidos ao ensaio. Dentro das condições experimentais deste estudo, os resultados obtidos sugerem que: os valores de destorque dos parafusos de fixação foram menores em todos os grupos submetidos ao ensaio; o destorque foi estatisticamente menor para os parafusos de titânio quando comparados os grupos HE-TiS (15,56±1,38 Ncm – 48%) / HE-AuS (18,15±1,85 Ncm – 56%) e os grupos HE-TiNS (23,76±1,59 Ncm – 74%) / HE-AuNS (27,06±1,23 Ncm – 84,5%); o destorque dos parafusos de titânio também foi estatisticamente menor quando utilizados nos grupos HE-TiS (15,56±1,38 Ncm – 48%), comparados aos grupos HI-TiS (18,56±1,14 Ncm – 58%). / The purpose of this study was to evaluate the abutment screw loosening when either submitted or not to cyclic loading. Six groups were composed: HE-TiS and HE-TiNS (external hexagonal implant and abutment, titanium abutment screw, submitted and not subimitted to cyclic loading), HE-AuS and HE-Au NS (external hexagonal implant and abutment, gold abutment screw, submitted not submitted to ciclyc loading), HI-TiS and HI-TiNS (internal hexagonal implant and abutment, titanium abutment screw, submitted and not submitted to ciclyc loading). In order to perform the cyclic loading, it was developed a device wich applied the maximum load of 120 N in the axial direction, with a slip of 0,3 mm on the crown oclusal surface with friction force of 28 N. The frequency was 60 cycles per minute for a duty of 500,000 cycles. The abutment screw was tightened to 32 Ncm and the loosening torque was measured after every 100,000 cycles in the submitted groups and every 24 hours after the tightening torque in the not-submitted groups. Within the limitations of this study, the results suggest that the loosening torque values were statistically significant lower in all groups submitted to the cyclic loading; the loosening torque was statiscally lower for titanium screws when compared HE-TiS (15,56±1,38 Ncm – 48%) / HE-AuS (18,15±1,85 Ncm – 56%) groups and HE-TiNS (23,76±1,59 Ncm – 74%) / HE-AuNS (27,06±1,23 Ncm – 84,5%) groups; the loosenig torque was also lower for the titanium screws when used to in the groups HE-TiS (15,56±1,38 Ncm – 48%) compared to HI-TiS (18,56±1,14 Ncm – 58%).
27

Avaliação mecânica da estabilidade de parafusos protéticos em diferentes sistemas de retenção pilar/implante / Mechanical evaluation of the prosthetic screw stability from different implant/abutment retention systems

Sérgio Rocha Bernardes 10 October 2008 (has links)
Foi analisada a variação da pré-carga de parafusos durante os cinco primeiros minutos depois de cada uma de cinco seqüências aperto e desaperto de parafusos de implantes dentários com diferentes sistemas de retenção pilar/implante. Extensômetros foram colados no terço cervical de implantes com interface de hexágono externo, hexágono interno e cone Morse. Um procedimento controlado de aperto e desaperto dos parafusos permitiu o arquivo dos valores de torque reverso, em relação ao aperto, e o campo de tensões gerado sobre o terço cervical dos implantes resultante da pré-carga do parafuso para cada uma das seqüências. Foram estudadas 30 amostras de implantes/pilares, dividas em oito grupos: implantes de hexágono externo com intermediário Munhão Universal e parafusos de titânio (Neodent, Curitiba, Brasil) apertados a 32 N.cm (EH.Ti.32); hexágono externo, Munhão Universal, parafuso de titânio recoberto por DLC, 32 N.cm (EH.dlc.32); hexágono interno, Munhão Universal, parafuso de titânio, 20 N.cm (IH.Ti.20); cone Morse, Munhão Universal peça única, 20 N.cm (MT.OP.20); cone Morse, Munhão Universal peça única, 32 N.cm (MT.OP.32); Cone Morse, Munhão Universal parafuso passante, 10 N.cm (MT.TS.10); no sétimo grupo foram usados as mesmas amostras do grupo MT.TS.10 a 10 N.cm, porém o desaperto foi realizado pelo intermediário (MT.TS.10.A); para o último grupo foram usados as mesmas amostras do grupo MT.TS.10 e MT.TS.10.A, porém o aperto dos parafusos foi de 15 N.cm e o desaperto também se deu pelo o intermediário (MT.TS.15.A). Os valores médios e desvio padrão (dp) de pré-carga encontrados para todas as seqüências de cada grupo foram de: EH.Ti.32 (27,75; dp 7,70); EH.dlc.32 (40,17; dp 10,16); IH.Ti.20 (219,61; dp 75,47); MT.OP.20 (129,19; dp 116,71); MT.OP.32 (137,97; dp 47,53); MT.TS.10 (39,55; dp 13,96); MT.TS.10.A (126,72; dp 44,05); MT.TS.15.A (194,41; 68,48). Entre os diferentes sistemas de retenção pilar/implante estudados, pode-se concluir que: existem relações únicas entre o valor de torque aplicado no parafuso e a pré-carga gerada sobre o terço cervical do implante, essas são diretamente influenciados pelo desenho da interface pilar/implante, tipo de parafuso de retenção e valor de torque aplicado; não foi observada perda de pré-carga dos parafusos de pilares, nem perda de resistência à torção no sentido anti-rotacional dos parafusos depois de esperados 5 minutos em 5 seqüências de aperto/desaperto. / The preload screw variation for the first five minutes after each one of five torque/untorque sequences from different implant/abutment retention systems was evaluated. Strain gauges were attached over the cervical third of external hex, internal hex and Morse taper implants. A controlled torque/untorque procedure allowed the record from the preload and untorque values of the samples in each one of the sequences. Thirty implant/abutment samples, divided in eight groups were studied: external hex implants with Universal post and titanium screws (Neodent, Curitiba, Brazil) screwed to 32 N.cm (EH.Ti.32); external hex, Universal post, DLC covered screw, 32 N.cm (EH.dlc.32); internal hex, Universal post, titanium screw, 20 N.cm (IH.Ti.20); Morse taper, single piece Universal post, 20 N.cm (MT.OP.20); Morse taper, single piece Universal post, 32 N.cm (MT.OP.32); Morse taper, Universal post trespassing screw, 10 N.cm (MT.TS.10); the same samples from the MT.TS.10 group were used for the seventh group, screwed to 10 N.cm, but the untorque was performed by the abutment (MT.TS.10.A); the same samples used with the MT.TS.10 and the MT.TS.10.A were used for the last group, but the screws were tightened to 15 N.cm and the untorque remained by the abutment (MT.TS.15.A). The mean and the stardad deviation (DP) found for the preloss in all the five sequences were of: EH.Ti.32 (27.75; SD 7.70); EH.dlc.32 (40.17; SD 10.16); IH.Ti.20 (219.61; SD 75.47); MT.OP.20 (129.19; SD 116.71); MT.OP.32 (137.97; SD 47.53); MT.TS.10 (39.55; SD 13.96); MT.TS.10.A (126.72; SD 44.05); MT.TS.15.A (194.41; SD 68.48). For the retention systems studied, it could be concluded that: there are single relations between screw untorque and preload over the implant cervical third, these are directely influenced by the implant/abutment interface design, screw type and torque value; there were not found post screw preload loss, neither torque resistance at the anti-rotational direction from the screws after the first five minutes in five torque/untorque sequences.
28

Ensaios mecânicos e estudo histológico da interface dos implantes vertebrais / Mechanical and histological studies of the vertebral screw interface

José Roberto Benites Vendrame 26 September 2006 (has links)
A cirurgia da coluna vertebral tem se desenvolvido muito nos últimos anos em decorrência da evolução dos sistemas de fixação. O comportamento da interface do parafuso com o osso continua sendo um aspecto não muito dominado. Como o parafuso é a âncora de sustentação, o trabalho procura investigar as técnicas de introdução do parafuso pedicular. Para atingir esse objetivo desenvolvemos o trabalho por meio de estudo com ensaios mecânicos de arrancamento e estudo histológico. Dois tipos de parafusos pediculares foram utilizados: parafuso pedicular do sistema USIS (Ulrich) e parafuso pedicular do sistema USS (Synthes). Os ensaios de arrancamento foram realizados em corpos de prova de madeira e poliuretano. O estudo histológico foi realizado em vértebras lombares de cadáver humano. No estudo envolvendo o parafuso USIS, foram testados os seguintes parâmetros: orifícios feitos com sonda e orifícios feitos com broca, todos do mesmo diâmetro do diâmetro interno do parafuso. Também foi testado o efeito do macheamento em relação ao não macheamento, nos orifícios feitos com broca. No estudo com os parafusos USS foram testados o efeito do diâmetro do orifício piloto tanto no estudo histológico como no arrancamento. No arrancamento destes parafusos também foi testado o efeito do tipo de orifício feito com sonda e com broca. O trabalho foi dividido em etapas: Primeira etapa foi o estudo de arrancamento do parafuso USIS; segunda etapa, estudo histológico de vértebra instrumentada com parafuso USIS, esta parte do trabalho foi constituída por análise de microscopia de luz e microscopia eletrônica de varredura; terceira etapa foi o arrancamento do parafuso USS; e quarta etapa foi o estudo histológico de vértebra instrumentada com parafuso USS. Os resultados da primeira etapa demonstraram que sonda teve efeito melhor do que broca, porque o resultado dos ensaios de arrancamento nos orifícios feitos com sondas teve maior força de arrancamento do que nos orifícios feitos por brocas. Na segunda etapa, análise histológica, verificou-se que os orifícios feitos por sonda apresentaram-se menores e com menor índice de fragmentação ao redor dos orifícios. Esses feitos tiveram diferença estatística significante, tanto na primeira, quanto na segunda etapa. Com relação ao macheamento não foi constatada diferença entre o não macheamento, em nenhuma das duas etapas. Na terceira etapa foi observado que, quando o orifício piloto ultrapassa o diâmetro interno do parafuso, ocorre tendência de queda na força de arrancamento de modo significativo, enquanto que orifício menor que o orifício piloto não tende a causar muita diferença na força de arrancamento em relação ao orifício correspondente ao diâmetro interno do parafuso. Também foi observado que o orifício feito com sonda oferece melhor força de ancoragem do que orifício feito com broca. Na quarta etapa foi constatado que quanto menor a broca para abrir o orifício piloto, menor o diâmetro do orifício, e não houve diferença significativa quanto ao índice de fragmentação ao redor do orifício entre os diferentes tamanhos de broca. Como conclusão pode-se dizer que sonda é melhor para se fazer o orifício piloto, uma vez que alarga menos o orifício, lesa menos as trabéculas ao redor do orifício e proporciona maior força de ancoragem do que broca. Também se pode concluir que o instrumental de menor diâmetro para abertura do orifício piloto é melhor, e o ponto crítico seria o diâmetro interno do parafuso. Não se deve fazer orifício piloto com instrumento de diâmetro maior que o diâmetro interno do parafuso. Não se constatou vantagem em relação ao fato de realizar ou deixar de realizar o macheamento. / Spine surgery has developed a lot in the last years because of the evolution of the fixation system. The behavior of a screw in the bone is still unknown in many ways. Because the screw is the anchor of sustentation, this work tries to find the answers involving the pedicle screw fixation. To reach this objective we developed this work based on mechanical and histological studies. Two kinds of pedicle screws were used: pedicle screw of the USIS (Ulrich) and pedicle screw of the USS system (Synthes). The pullout tests were made in wood and polyurethane. The histological study was done in lumbar vertebra of humans. In the study about the USIS screw, the follow parameters were tested: hole done with probe and hole done with drill, all of the same inner diameter of the screw. The effect of tapping and not tapping the hole done with drill was tested. In the USS screw study, the effect of the diameter pilot hole in the pullout tests and its historical analysis was seen. In the pullout tests of these screws, both kind of holes done with probes and a drill were tested. The work was divided into stages; first stage was the study of the pullout of the USIS screw; second stage was two studies, a light-microscopic one and a sweeping-electronic-microscope one of the slides of the instrumented vertebra with USIS screws; third stage was the study of the USS screws pullout comparing the relationship between the diameter of the holes and the inner diameter of the screw together with the type of hole (drill and probe); fourth stage was light-microscopic histological study of the instrumented vertebras which had had USIS screws. Results of the first stage showed that probes were more efficient than drills because the mechanical tests of pullouts from probe-made-holes showed the need of the use of a stronger force. In the second stage, a light-microscopic analysis showed that probe-made-holes had a lesser minimum diameter and a lower index of fragmentation than drill-made holes. With relation to the tapping, there was no difference between the holes. Under electronic microscope sweeping, it was seen that probes betters compact the bone around the screw. In the third stage, it was seen that when 9 the pilot orifice was greater than the screws internal diameter a significantly lower force was needed for pullout, while when the pilot orifice was smaller it did not significantly increase the force needed. It was also seen that probe-made-holes had a better anchorage than the drill-made-holes. In the fourth stage, the histological analysis of the slides done with light-microscopy showed that the smaller the diameter of the drill the smaller minimum diameter; there was no significant difference between fragmentation indexes. Conclusion: Probes are better than drills to make a pilot hole because they cause less damage to the surrounding bone and give a stronger anchorage for the screw; the smaller the instrument used to make the pilot hole, better will be the strength of the screws anchorage; the critical point which the hole must not exceed is the internal diameter of the screw. Tapping, or not, makes no difference to the anchorage.
29

Avaliação do destorque do parafuso protético de diferentes tipos de conexões com coroas longas

Rocha, Elissa Almeida 26 August 2014 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-06-26T12:34:48Z No. of bitstreams: 1 elissaalmeidarocha.pdf: 1048455 bytes, checksum: 482abe6dc9b27c43e6590f8c48ec4789 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-08-07T20:35:48Z (GMT) No. of bitstreams: 1 elissaalmeidarocha.pdf: 1048455 bytes, checksum: 482abe6dc9b27c43e6590f8c48ec4789 (MD5) / Made available in DSpace on 2017-08-07T20:35:48Z (GMT). No. of bitstreams: 1 elissaalmeidarocha.pdf: 1048455 bytes, checksum: 482abe6dc9b27c43e6590f8c48ec4789 (MD5) Previous issue date: 2014-08-26 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo deste estudo foi avaliar a influência de diferentes conexões no destorque do parafuso Neotorque sobre implantes com proporção coroa - implante (2:1), estudo in vitro, após ciclagem mecânica. Trinta implantes de 9 mm x 3,75 mm (Neodent®-Curitiba, Paraná, Brasil) foram utlizados, sendo 10 de cada tipo de conexão (CM,HE, HI) com seus respectivos munhões universais: (CM) ( 3,3/6/3,5), HE e HI ( 4,5,6,3) (Neodent®-Curitiba, Paraná, Brasil). Os implantes foram inseridos individualmente em resina acrílica (JET, Clássico, São Paulo, Brasil) com auxílio de um cilindro calcinável padronizado ( 2,5x1,5). O torque nos parafusos foi feito com torquímetro digital (Lutron TQ – 680, Impac, São Paulo), o grupo HE recebeu 30 N.cm, o grupo CM 15 N.cm e o grupo HI 20N.cm. Posteriormente a aplicação do torque, as coroas foram posicionadas sobre os pilares protéticos com vaselina sólida (Farmax, Divinópolis, Brasil) e em seguida foram submetidos à ciclagem mecânica (Simulador de Fadiga Mecânica, ERIOS, modelo ER – 11000), com aplicação de uma carga de 120N, 75 ciclos/s por 1.000.000 ciclos a 1 Hz, submersos em água destilada. Por fim, o destorque foi mensurado com o auxílio de um torquímetro digital (Lutron TQ-680, Impac, São Paulo/SP). Os valores de média de destorque (desvio padrão) obtidos após ciclagem mecânica foram: CM - 13,4 (1,83) N.cm, HI – 17 (1,69) N.cm e HE – 25,6 (1,95) N.cm. O teste de ANOVA (p<0,05) mostrou que não houve diferença estatisticamente significante entre os grupos (p=0,526) com relação aos diferentes tipos de conexão pilar - implante e a proporção coroa (2) – implante (1) após ciclagem mecânica. Para avaliar cada grupo independentemente em relação a perda de carga do torque de fechamento após ciclagem mecânica, foi realizada o teste t de student independente (p<0,05), obteve-se resultado estatisticamente significante para perda de torque inicial dentro de cada grupo: CM (0,022), HI (0,00) e HE (0,00). Concluiu-se que o tipo de conexão pilar - implante e da proporção coroa – implante (2:1) não influenciou na perda de torque após a ciclagem mecânica; a ciclagem mecânica influenciou na perda de torque dentro de cada grupo de conexão pilar – implante. / The aim of this study was to evaluate the influence of different connections in detorque Neotorque screw implant with crown ratio - implant (2:1), in vitro study, after mechanical cycling. Thirty of 9 mm x 3.75 mm (Neodent®-Curitiba, Paraná, Brazil) were utlizados implants, 10 of each connection type (CM, HE, HI) with their universal posts: (CM) ( 3, 3/6 / 3,5), HE and HI ( 4,5,6,3) (Neodent®-Curitiba, Paraná, Brazil). The implants were inserted individually in acrylic resin (JET, Classic, São Paulo, Brazil) using a standardized burn-cylinder ( 2,5x1,5). The torque on the bolts was done with digital torque meter (Lutron TQ - 680, Impac, São Paulo), the HE group received 30 N.cm, the CM group and 15 N.cm the HI group 20N.cm. Subsequently the application of torque, the crowns were placed on the abutments with petrolatum (Farmax, Divinópolis, Brazil) and then were subjected to mechanical cycling (Simulator Mechanical Stress, Erios, ER Model - 11000), with application of a 120N load, 75 cycles / sec per 1 million cycles at 1 Hz, immersed in distilled water. Finally, the detorque was measured with the aid of a digital torque meter (Lutron TQ-680, Impac, São Paulo / SP). The (standard deviation) values of average detorque obtained after mechanical cycling were: CM - 13.4 (1.83) N.cm, HI - 17 (1.69) and HE N.cm - 25.6 (1, 95) N.cm. The ANOVA test (p <0.05) showed no statistically significant difference between groups (p = 0.526) with respect to different types of abutment connection - implant and the crown ratio (2) - implant (1) after cycling mechanics. To evaluate whether each group compared to the pressure drop in torque after mechanical closure cycling, independent Student t (p <0.05) was performed, there was a statistically significant result for loss of initial torque in each group : CM (0.022), HI (0.00) and HE (0.00). It was concluded that the type of abutment connection - implant and crown ratio - implant (2: 1) no effect on the loss of torque after mechanical cycling; mechanical cycling effect on the loss of torque within each group of connection pillar - implant.
30

Análise numérica e experimental de sistema de ar condicionado em edifícios verdes

PEREIRA, Gutenberg da Silva 22 February 2016 (has links)
Submitted by Rafael Santana (rafael.silvasantana@ufpe.br) on 2017-07-12T17:40:35Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Tese_Gutenberg da Silva Pereira_1.pdf: 6410667 bytes, checksum: ddf1e84a9a1b8bcce71836f13e8707fa (MD5) / Made available in DSpace on 2017-07-12T17:40:35Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Tese_Gutenberg da Silva Pereira_1.pdf: 6410667 bytes, checksum: ddf1e84a9a1b8bcce71836f13e8707fa (MD5) Previous issue date: 2016-02-22 / Com a atual escassez de energia, alta demanda e aumento do custo da energia elétrica, verifica-se que uma questão importante é a melhoria da eficiência dos sistemas de climatização dentro de um padrão de eficiência certificado possibilita-se, assim, para uma comparação real de qual é a melhor opção de layout e operação dos sistemas, já que os sistemas de climatização são responsáveis por uma alta parcela do consumo energético. O presente trabalho se propõe a comparar dois sistemas de refrigeração diferentes, usando chiller de compressão de vapor, para a climatização de ambientes. Foram propostas diferentes modalidades para a comparação em operações isoladas e ações combinadas. Essas operações são avaliadas nos conceitos de edifícios verdes. Foi desenvolvido um modelo matemático baseado nos princípios de conservação de massa e energia, complementado por várias funções, de modo a determinar as propriedades termofísicas e eficiências dos compressores. O modelo avalia a influência dos parâmetros operacionais principais do sistema de refrigeração a água gelada operando em três configurações diferentes. As equações do modelo foram resolvidas pelo programa EES (Engineering Equation Solver). Os resultados mostraram que o sistema com compressão diferenciada apresenta COP igual ao do sistema com chiller parafuso na faixa de 0 a 300 TRs, e um COP superior em média de 9% na faixa de 400 a 800 TRs. / With the current energy shortages, high demand and rising cost of electricity, it turns out that an important issue is the improvement of the air conditioning efficiency within a standard of efficiency certificate for a real comparison of what is the better layout option and operation of systems, as the HVAC systems account for a high share of energy consumption. This study aims to compare two different cooling systems using vapor compression chiller for air conditioning environments. They were different proposals modalities for comparison in isolated and combined action operations. These transactions are valued on the concepts of green buildings. A mathematical model was developed based on the principles of conservation of mass and energy, supplemented with various functions in order to determine the thermophysical properties and efficiencies of the compressors. The model evaluates the influence of the main operating parameters of the cold water cooling system operating in three different configurations. The model equations were solved by EES program (Engineering Equation Solver). The results showed that the system presents differentiated compression COP equal to the screw chiller systems in the range from 0 to 300 RTs and a higher COP (average of 9%) in the range of 400 to 800 TR.

Page generated in 0.0454 seconds