Spelling suggestions: "subject:"positrons 2mission"" "subject:"positrons 2emission""
11 |
Development and analysis of radiolabeled magnetic nanoparticles for positron emission tomography and magnetic resonance imagingGlaus, Charles R. M. 03 November 2008 (has links)
Nanoparticles possess unique characteristics that make them well suited for molecular imaging. Particles can be synthesized in a systematic fashion with tight control over diameter and surface chemistry. Contrary to existing gadolinium-based MRI contrast agents, nanoparticle MRI contrast agents circulate in the blood for long periods of time, offer higher sensitivity, and exhibit little known toxicity. The qualities of nanoparticles are also well suited to the design of PET probes. Because of their large surface area nanoparticles can be radiolabeled at high specific activity, increasing the sensitivity of detection as well as the payload of therapeutic isotopes.
The work presented here focuses on the development and biological application of novel radiolabeled magnetic nanoparticles for multimodal PET/MRI imaging. The nanoparticle probes contained crystalline iron oxide cores capable of producing strong MRI contrast. Cores were coated with either a micelle composed of functionalized PEGylated lipids, or a cross-linked dextran shell modified with heterobifuntional PEG polymers. For PET imaging, magnetic nanoparticles were labeled with the radionuclide 64Cu. Copper‐64 is a cyclotron produced positron emitter used for PET imaging. With a 12.7 hour half-life, 64Cu can be used to image particles in vivo for up to 48 hr and can be used to evaluate ex vivo biodistribution for 72 hours. 64Cu nuclides also undergo β‐ decay, making it a useful isotope for radiotherapy. Nanoparticles were labeled with 64Cu and PET and MRI contrast and evaluated using phantoms. Pharmacokinetic information was measured using in vivo small animal PET/CT and ex vivo biodistribution at multiple time points. Particles were targeted to the angiogenesis marker αvβ3 integrin using a cyclized arginine-glycine-aspartic acid (RGD) peptide with high affinity for αvβ3 and tested in two tumor models. A unilateral tumor model was constructed using the αvβ3-positive U87MG glioblastoma line, and a bilateral model was constructed using the M21 (αvβ3 positive) and M21L (αvβ3 negative) melanoma lines. In vivo PET/CT and MRI showed that targeted nanoparticles produced both PET and MRI contrast in tumors. In conclusion, we report the development of magnetic nanoparticles for dual‐PET/MR imaging. These findings provide insight into the design and development of future multimodality PET/MRI probes.
|
12 |
Stratégies diagnostiques et qualité de vie en oncologie bronchopulmonaire - Programme d'évaluation de la TEP dans l'inter-région Grand-Est / Diagnostic strategies and quality of life in pulmonary oncology an evaluation program of PET implantation in the Northeastern Regions of FranceLemonnier, Irawati 17 January 2011 (has links)
Introduction : L'installation de caméras de Tomographie à Emission de Positons (TEP) a eu lieu en 2003 dans l'inter région Grand-Est de la France. Plusieurs études ont montré ses performances diagnostiques et ses bénéfices en évitant: des interventions de chirurgie exploratrice devenue inutile (thoracotomie aux séquelles douloureuses, laparotomie exploratrice), et certains examens complémentaires d'imagerie ou d'exploration fonctionnelle inutile. Objectifs : 1) évaluer le changement des stratégies diagnostiques du Nodule Pulmonaire Isolé (NPI) et du Cancer du Poumon Non à Petites Cellules (CPNPC) induit par l'implantation de la TEP dans l'inter - région Grand - Est de la France ; 2) mesurer l'impact du changement sur la qualité de vie des patients atteints d'un NPI et d'un CPNPC ; et 3) étudier le rôle pronostique de la QV sur la survie des patients atteint d'un CPNPC.Méthodes : Etude prospective multicentrique constituant 2 cohortes « Avant (2001 - 2002) » et « Après (2004 - 2005) » de l'implantation de la TEP. Ont été recueillis : les caractéristiques sociodémographiques des patients, clinique du NPI et du CPNPC, les examens diagnostiques et traitements réalisés jusqu'à 6 mois après la fin du bilan. Deux auto-questionnaires de QV (SF36 et QLQ C-30) ont été distribués à 3 et 6 mois après la fin du bilan diagnostique.Résultats : 1) Nous avons observé une diminution du nombre d'examens réalisés au cours du bilan diagnostique d'un NPI de 4 examens en phase avant à 3 en moyenne en phase après. Néanmoins, la fréquence des examens invasifs jugés évitables a posteriori pratiqués chez les patients ayant un NPI bénin n'était pas différente (47% phase avant versus 49% phase après). Un an après son installation, la TEP a été utilisée chez 11% des patients. 2) Les patients atteints d'un NPI et quelque soit sa nature, maligne ou bénigne, ont eu un score moyen de QV plus bas (-8 à -32 points, p<0.001) que celui mesuré dans la population générale française indépendamment du sexe et de l'âge. Les scores QV des patients ayant un NPI bénin se révélaient être statistiquement plus élevés que ceux des patients ayant un NPI malin, notamment dans les dimensions « fonctionnement social », « rôle physique » et « rôle émotionnel » (+10, +14 et +18 points respectivement, p=0,02 à 0,04).3) Les bons scores en fonctionnement physique en SF-36 (HR=0.78 ; IC=0.68 - 0.90 ; p<0.001), et en la limitation due à l?état physique en QLQ-C30 (HR=0.53 ; IC=0.59 - 0.89 ; p=0.003) indiquant une bonne perception des patients sur leurs fonctionnement physique sont liés à une meilleure survie. Les symptômes élevés de constipation (HR=1.18 ; IC=1.005-1.38 ; p=0.04) en QLQ-C30, par contre, est lié à une mauvaise survie. Le sexe féminin est lié à une meilleure survie (HR=0.55 ; IC=0,33 - 0,94 ; p=0,04). Cependant, le stade III et IV du CPNPC est associé à une mauvaise probabilité de survie (HR=1,72 ; IC=1,16 - 2,57 ; p=0,007).Discussion/conclusion : Les stratégies diagnostiques du NPI ont changé. L'impact de cette maladie, mesuré de façon subjective par la qualité de vie (QV) des patients peut indiquer certains domaines essentiels à améliorer dans sa prise en charge car une meilleure QV en oncologie broncho-pulmonaire est associée à une meilleure survie / Background: The Positron Emission Tomography was installed in 2003 in the North-eastern region of France. Previous studies showed its diagnostic performance and its benefices in avoiding: surgical exploratory interventions proved to be unnecessary a posteriori (for example, thoracotomy or laparotomy with painful consequences), and certain complementary imaging tests or unnecessary functional explorations. Objectives : 1) to evaluate changes in diagnostic strategies of Solitary Pulmonary Nodule (SPN) and Non Small Cell Lung Cancer (NSCLC) induced by the implantation of PET in the Northeastern region of France ; 2) to mesure the impact of these changes on the health related quality of life (HRQoL) of patients with SPN and NSCLC; and 3) to study the prognostic role of the HRQoL on the survival of patients with NSCLC.Methodes: An observational, prospective, multi-center design was applied. Two cohorts « Before (2001 - 2002) - After (2004 - 2005) » the PET implantation in the regions were settled up. Data collected included: patients' socio-demographic and clinical characteristics, the diagnostic tests and then treatments that were carried out during 6 months after the end of the diagnostic process. Two HRQoL questionnaires (the generic questionnaire SF-36 and the cancer specific one QLQ-C30) were distributed at 3 and 6 months after the end of the diagnostic process.Results:1) The number of diagnostic tests of patients with SPN decreased significantly from a mean of 4 in the before-PET to 3 tests in the after-PET period. Meanwhile, there was not any difference of the frequency of invasive tests considered unnecessary aposteriori for patients with benign SPN (47% before-PET versus 49% after-PET period). One year after its installation, the PET was used in 11 % of diagnostic strategies. In 7.7% of cases it was used after the bronchoscopy. 2) A comparison of the QoL with that of the French general population revealed that patients with SPN, whatever the diagnosis, benign or malignant, had worse mean scores (-8 to -32 points, p<0.001) compared to the general population with similar age and sex. A difference of 24, 30 and 32 points were observed in the "physical functioning", "emotional role" and "physical role" (p<0.001). The scores of patients with benign nodule were higher than those of malignant, especially on "social functioning", "physical role", and "emotional role" (+10, +14 and +18 points respectively, p=0.02 to 0.04). 3) Good scores on "physical functioning" of SF-36 (HR=0.78; CI=0.68 - 0.90; p<0.001) as well as "role functioning" of QLQ-C30 (HR=0.53; CI=0.59 - 0.89; p=0.003) were related to a better survival. Higher symptoms of constipation (HR=1.18; CI=1.005-1.38; p=0.04) in QLQ-C30 were associated to a worse one. While being a woman was associated to a better survival (HR=0.55 ; CI=0,33 - 0,94 ; p=0,04), the stage III and IV of the NSCLC was related to a lower one (HR=1,72 ; CI=1,16 ? 2,57 ; p=0,007) .Conclusion: The diagnostic strategies of SPN changed after PET was available for medical practice. This study showed the negative impact of SPN to patients' HRQoL. It indicates the domains in which health practitioners could interfere in order to improve the management of these diseases, because this study confirmed previous studies in pulmonary oncology, that patients' QoL is related to the survival
|
13 |
Évaluation de la correction du mouvement respiratoire sur la détection des lésions en oncologie TEP / Motion correction evaluation on the detectability of lesions in PET oncologyMarache-Francisco, Simon 14 February 2012 (has links)
La tomographie par émission de positons (TEP) est une méthode d’imagerie clinique en forte expansion dans le domaine de l’oncologie. De nombreuses études cliniques montrent que la TEP permet, d’une part de diagnostiquer et caractériser les lésions cancéreuses à des stades plus précoces que l’imagerie anatomique conventionnelle, et d’autre part d’évaluer plus rapidement la réponse au traitement. Le raccourcissement du cycle comprenant le diagnostic, la thérapie, le suivi et la réorientation thérapeutiques contribue à augmenter le pronostic vital du patient et maîtriser les coûts de santé. La durée d’un examen TEP ne permet pas de réaliser une acquisition sous apnée. La qualité des images TEP est par conséquent affectée par les mouvements respiratoires du patient qui induisent un flou dans les images. Les effets du mouvement respiratoire sont particulièrement marqués au niveau du thorax et de l’abdomen. Plusieurs types de méthode ont été proposés pour corriger les données de ce phénomène, mais elles demeurent lourdes à mettre en place en routine clinique. Des travaux récemment publiés proposent une évaluation de ces méthodes basée sur des critères de qualité tels que le rapport signal sur bruit ou le biais. Aucune étude à ce jour n’a évalué l’impact de ces corrections sur la qualité du diagnostic clinique. Nous nous sommes focalisés sur la problématique de la détection des lésions du thorax et de l'abdomen de petit diamètre et faible contraste, qui sont les plus susceptibles de bénéficier de la correction du mouvement respiratoire en routine clinique. Nos travaux ont consisté dans un premier temps à construire une base d’images TEP qui modélisent un mouvement respiratoire non-uniforme, une variabilité inter-individuelle et contiennent un échantillonnage de lésions de taille et de contraste variable. Ce cahier des charges nous a orientés vers les méthodes de simulation Monte Carlo qui permettent de contrôler l’ensemble des paramètres influençant la formation et la qualité de l’image. Une base de 15 modèles de patient a été créée en adaptant le modèle anthropomorphique XCAT sur des images tomodensitométriques (TDM) de patients. Nous avons en parallèle développé une stratégie originale d’évaluation des performances de détection. Cette méthode comprend un système de détection des lésions automatisé basé sur l'utilisation de machines à vecteurs de support. Les performances sont mesurées par l’analyse des courbes free-receiver operating characteristics (FROC) que nous avons adaptée aux spécificités de l’imagerie TEP. L’évaluation des performances est réalisée sur deux techniques de correction du mouvement respiratoire, en les comparant avec les performances obtenues sur des images non corrigées ainsi que sur des images sans mouvement respiratoire. Les résultats obtenus sont prometteurs et montrent une réelle amélioration de la détection des lésions après correction, qui approche les performances obtenues sur les images statiques. / Positron emission tomography (PET) is nuclear medicine imaging technique that produces a three-dimensional image of functional processes in the body. The system detects pairs of gamma rays emitted by a tracer, which is introduced into the body. Three-dimensional images of tracer concentration within the body are then constructed by computer analysis. Respiratory motion in emission tomography leads to image blurring especially in the lower thorax and the upper abdomen, influencing this way the quantitative accuracy of PET measurements as well a leading to a loss of sensitivity in lesion detection. Although PET exams are getting shorter thanks to the improvement of scanner sensitivity, the current 2-3 minutes acquisitions per bed position are not yet compatible with patient breath-holding. Performing accurate respiratory motion correction without impairing the standard clinical protocol, ie without increasing the acquisition time, thus remains challenging. Different types of respiratory motion correction approaches have been proposed, mostly based on the use of non-rigid deformation fields either applied to the gated PET images or integrated during an iterative reconstruction algorithm. Evaluation of theses methods has been mainly focusing on the quantification and localization accuracy of small lesions, but their impact on the clinician detection performance during the diagnostic task has not been fully investigated yet. The purpose of this study is to address this question based on a computer assisted detection study. We evaluate the influence of two motion correction methods on the detection of small lesions in human oncology FDG PET images. This study is based on a series of realistic simulated whole-body FDG images based on the XCAT model. Detection performance is evaluated with a computer-aided detection system that we are developing for whole-body PET/CT images. Detection performances achieved with these two correction methods are compared with those achieved without correction, ie. with respiration average PET images as well as with reference images that do not model respiration effects. The use of simulated data makes possible the creation of theses perfectly corrected images and the definition of known lesions locations that serve as a reference.
|
Page generated in 0.091 seconds