• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

La inteligencia general (g), la eficiencia neural y el índice velocidad de conducción nerviosa: una aproximación empírica

Bonastre Rovira, Rosa Maria 01 April 2005 (has links)
Para valorar la asociación de las diferencias individuales en inteligencia psicométrica (CI) con las diferencias en eficiencia neural, utilizamos los potenciales evocados cerebrales visuales (VEP) y el índice de la velocidad de conducción nerviosa (VCN) en la vía visual derivado de ellos. En una muestra de 20 sujetos (10 mujeres y 10 hombres) se registró la latencia P100 de los VEP (el primer potencial eléctrico transitorio registrado sobre el córtex visual primario), se tomaron medidas de longitud de la vía visual mediante resonancia magnética (RM), y se aplicaron los tests de Wechsler y las AMP de Raven para las medidas de inteligencia psicométrica o cociente intelectual (CI). Mediante los ANOVA no se hallaron diferencias significativas entre mujeres y hombres para ninguno de los parámetros neurofisiológicos (latencias y amplitudes) de los VEP, ni para ninguno de los valores del índice de la VCN neurovisual, ni para ninguna de la medidas psicométricas de inteligencia general, mientras, y era de esperar, sí se hallaron diferencias significativas en las medidas de longitud (tamaño) de la cabeza por RM. Los resultados no muestran correlación entre el parámetro tiempo medido por la latencia P100 o las medidas de velocidad de los VEP y las medidas psicométricas de inteligencia fluida (Gf). Este resultado no soportaría la hipótesis del tiempo de la transmisión neural rápida para la inteligencia general (g). La longitud (tamaño) de la cabeza no fue correlacionada con los parámetros de los VEP, pero sí fue correlacionada con las medidas psicométricas tanto de inteligencia cristalizada (aritmética) como de inteligencia fluida (no verbal). En el análisis fueron utilizadas las medidas de la longitud de la cabeza (distancia) y la latencia P100 (tiempo de transmisión neural) para calcular el cociente de velocidad (distancia/tiempo) del índice denominado VCN neurovisual (subcortical) que presentó un patrón de correlaciones positivas con las medidas psicométricas de inteligencia no verbal (CI) de aproximadamente (r=0.40-50) (significativas después de aplicar el contraste de Bonferroni). Sin embargo, a pesar de los resultados, la magnitud y consistencia de la correlación posiblemente venga explicada y determinada más por el efecto de la covariante de longitud (tamaño) de la cabeza que por el efecto de las diferencias en las variables biológicas (neurofisiológicas) de los VEP. Desde el punto de vista conceptual, la exploración de la asociación entre la inteligencia psicométrica y la eficiencia neural mediante la introducción del indicador VCN no está clara a nivel (elemental) de los procesos biológicos de la información. / To value the association of individual differences in psychometric intelligence (IQ) with the differences for neural efficiency, we used the visual evoked cerebral potentials (VEP) and the index nerve conduction velocity (VCN) in a brain nerve pathway derived from them. In a sample of 20 subjects (10 women and 10 men) were tested for latency P100 of the VEP (a visually evoked potential recorded over the visual primary cortex). Measurements of length visual pathway by means of magnetic resonance imaging (RMI) were taken, and Wechsler's tests and Raven's AMP for the measures of quotient intellectual (IQ) were applied. ANOVA did not show significant differences between women and men for any of the neurophysiological parameters (latencies and amplitudes) of the VEP, nor for none of the values of the index VCN neurovisual, nor for none of psychometric measures for general intelligence. While, as it was thought, significant differences were found in the measures of head length by RMI. The results do not show correlation between the parameter time measured by a latency P100 or the speed measures of the VEP and the psychometric measures of fluid intelligence (Gf). This result would not support the hypothesis of faster neural transmission time for general intelligence (g). The head length was not correlated by the parameters of the VEP, but it was correlated with both psychometric intelligence measures crystallized (arithmetical) and fluid intelligence. In the analysis, the measures of head length (distance) and the latency P100 (neural transmission time), were used to calculate the velocity quotient (distance / time) of the index named VCN neurovisual (subcortical) showing a pattern of positive correlations with the psychometric measures of nonverbal IQ of approximately (r=0.40 50, significant after correcction for Bonferroni's contrast). Nevertheless, in spite of the results, the magnitude and consistency of the correlation possibly come explained and determined more by the effect of the covariante of head length (head size) than by the effect of the differences in the biological (neurophysiological) variables of the VEP. From the conceptual point of view, the exploration of the association between the psychometric intelligence and neural efficiency by means of the introduction of the index VCN is not clear to (elementary) level of the biological processes of information.
2

Electrodiagnóstico: protocolo clínico y estandarización de Electrorretinografía (ERG)y Potenciales Evocados Visuales (PEV)en el perro beagle

Torres Soriano, Desireé 02 December 2010 (has links)
La presente tesis se ha basado en conseguir dos objetivos fundamentales: diseñar un protocolo clínico de electrodiagnóstico para obtener el electrorretinograma (ERG) y los potenciales evocados visuales (PEV) en el perro beagle, y elaborar un estándar de los resultados para esta raza.Hemos establecido un protocolo clínico de electrodiagnóstico adaptado a nuestro equipo de diagnóstico, a las características de nuestros pacientes y, en general, a los recursos materiales que teníamos a nuestra disposición. De este modo, hemos conseguido realizar un protocolo de corta duración que nos permite evaluar la funcionalidad de las vías visuales del perro y detectar posibles anomalías.Concluimos que el protocolo que hemos establecido nos permite registrar adecuadamente el ERG y los PEV para el perro beagle, así como obtener resultados fiables y reproducibles que podemos considerar como estándar para esta raza canina y este equipo de electrodiagnóstico. / The aims of this thesis were firstly to design a clinical protocol for Electro, electroretinography (ERG) and visual evoked potential (VEP) in the Beagle dog and, secondly, to develop a performance standard for this breed. A clinical electrodiagnostic protocol adapted to our diagnostic equipment was established. This protocol considered the characteristics of the patients as well as the material resources at our Institution. This protocol allowed us to evaluate the functionality of the visual pathways in order to detect any anomalies. It can be concluded that the protocol established in this Thesis allows to record accurately the ERG and the VEP of Beagle dogs. Moreover, the results are reliable and reproducible and it could be considered as a good standard for this breed when these electrodiagnosis tools are employed.

Page generated in 0.234 seconds