• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 139
  • 13
  • 13
  • 13
  • 13
  • 12
  • 2
  • 1
  • 1
  • Tagged with
  • 139
  • 139
  • 103
  • 88
  • 78
  • 70
  • 58
  • 55
  • 42
  • 42
  • 40
  • 28
  • 24
  • 21
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Análise do estresse gerado em componentes de prótese fixa implanto-suportada através do uso de extensômetros

Letícia Borges Jacques 05 May 2000 (has links)
O êxito clínico dos implantes osseointegrados é amplamente determi nado, pela maneira como o estresse mecânico é transferido do implante, ao tecido ósseo circundante, sem gerar forças de grande magnitude, o que poderia colocar em risco a longevidade do próprio implante e da restauração protética. Inúmeros aprimoramentos técnicos, assim como desenhos e ligas metálicas alternativas para a confecção de infra-estruturas, têm sido propostos para melhorar os procedimentos protéticos. O objetivo deste trabalho foi verificar a distribuição de estresse em componentes de prótese fixa implanto-suportada, através do uso de extensômetros, em função de duas ligas metálicas. Corpos de prova simulando infra-estruturas para uma situação de prótese total fixa mandibular, foram confeccionados em liga de cobalto -cromo e paládio-prata e posicionados sobre um modelo-mestre. Uma carga estática vertical de 100N foi aplicada na extremidade livre, a uma distância de 10, 15 e 20mm para distal do centro do intermediário terminal. Os resultados demonstraram que em grandes extensões de cantilever, a liga de cobalto-cromo apresentou um padrão de distribuição de forças semelhante à liga de paládio-prata com cantilever curto. Independente do local de aplicação da força e da liga utilizada na confecção das infra-estruturas, o intermediário mais próximo do ponto de aplicação da carga foi o que registrou a maior deformação específica. O emprego de uma liga de cobalto-cromo na confecção de infra-estruturas para prótese sobre implantes pode permitir braços de cantilever mais extensos. / The clinical success of osseointegrated implants are largely influenced by the manner mechanical stresses are transfered from implant to surrounding bone, without generating forces of a magnitude that would jeopardize the longevity of implant and prosthesis. A variety of technical improvements, as well as alternative framework designs and alloys have been reported to improve prosthetic procedures. The aim of this study was to analyse stress distribution on components of a fixed implant-supported prostheses, fabricated with two metal alloys. The samples simulated a typical mandibular fixed complete -arch framework and were fabricated on cobalt-chromium alloy and palladium-silver alloy and positioned on a master-cast. A vertical estatic load of 100N was applied on the cantilever arm at a distance of 10, 15 and 20mm from the center of distal abutment. Strain gauges were positioned on the mesial and distal aspects of each abutment to capture deformation.The results demonstrated that for large cantilever extensions, the cobalt-chromium alloy presented a pattern of force distribution similar to that observed with palladium-silver alloy with short cantilever. Irrespective of the point of load application and the metal alloy used in the framework construction, the abutment closer to the point of load application registered the highest especific deformation. Using a cobalt-chromium alloy may allow longer cantilever arms.
22

Estudo in vitro da deformação permanente em grampos a barra fundidos em ligas de cobalto-cromo e em titânio comercialmente puro, submetidos a testes de tensão-deformação. / Permanent deformation in vitro study of “I” bar clasps cast with cobalt-chromium alloy and commercially pure Titanium, submitted to tension-deformation trials.

Mauricio José Arrais 14 April 2005 (has links)
Foram realizados testes de inserção e remoção de grampos a barra em “I”, fundidos com liga de Cobalto-Cromo (CoCr) e com Titânio comercialmente puro (Ti). Foi utilizada uma máquina oscilante de teste para verificar o comportamento elástico destes grampos que atuaram sobre superfícies metálicas com graus de retenção de 0,25mm e 0,50mm. Dez grampos de CoCr e dez de Ti foram submetidos a 12.500 ciclos de teste (cada) sobre as superfícies metálicas. A ocorrência da deformação permanente dos grampos foi mensurada por meio de relógios comparadores colocados sobre as pontas dos retentores, sendo que a leitura destes relógios ocorreu a cada 500 ciclos. Os resultados desta pesquisa in vitro indicaram que, após os 12.500 ciclos, não foram observadas fraturas nos grampos. E ainda que os grampos feitos em liga de CoCr sofreram menores deformações permanentes do que os de Ti para ambas as retenções. / Insertion and removal trials of “I” bar clasps cast with cobalt-chromium alloy and commercially pure Titanium were carried out. An oscillating trial machine was utilized to verify the elastic behavior of these clasps, which acted on metallic surfaces with 0.25mm and 0.50mm degrees of retention. Ten CoCr clasps and ten Ti clasps were submitted to 12,500 trial cycles (each) on the metallic surfaces. The permanent deformation of the clasps was measured b y comparative gauges placed on the tips of the clasps, and the reading of the gauges was carried out every 500 cycles. The results of this in vitro research showed that after the 12,500 cycles clasp fractures were not observed and that clasps made with CoCr alloy suffered less permanent deformation than Ti ones for both degrees of retention.
23

Avaliação da resistência à fratura de pré-molares superiores tratados endodonticamente restaurados com 'Inlays' confeccionados com dois tipos de materiais e cimentada com três cimentos resinosos / Evaluation of fracture resistance of endodontically treated maxillary premolars, restored with inlays made with two types of materials and luted with three resin cements

Ortega, Vagner Leme 28 November 2000 (has links)
Este trabalho teve como objetivo comparar a resistência à fratura por compressão axial de pré-molares superiores tratados endodonticamente com preparos do tipo MOD, restaurados com “inlays" de cerâmica (IPS-Empress 2) e de cerômero (Targis), cimentadas com três cimentos resinosos de dupla polimerização (Enforce, Variolink II e Panavia F). Selecionaram-se 60 pré-molares superiores hígidos, livres de cáries e trincas, que foram extraídos por razões ortodônticas. Esses dentes foram distribuídos uniformemente, de acordo com suas dimensões vestíbulo-linguais e mésio-distais, em 6 grupos determinados pela combinação dos materiais restauradores e dos cimentos utilizados. Após a cimentação das restaurações e ciclagem térmica, os corpos de prova foram posicionados em uma máquina de ensaio universal e submetidos a uma compressão axial pelo ação de um cilindro de aço com 8mm de diâmetro, numa velocidade de 0,5mm/min, que contactava somente as vertentes triturantes das cúspides vestibular e lingual. Os melhores resultados foram obtidos, em ordem decrescente, com os cimentos Enforce (107,57kgf e 90,21kgf), Variolink II (86,44kgf e 84,07kgf) e Panavia F (82,43kgf e 76,73kgf) para as restaurações com Targis e IPS-Empress 2, respectivamente. Foram encontradas diferenças estatisticamente significantes entre os cimentos Enforce e Panavia F, independente do material restaurador utilizado. Considerando um mesmo agente cimentante, os resultados obtidos com os grupos de dentes restaurados com Targis foram ligeiramente superiores aos restaurados com IPS-Empress 2, sem apresentarem, entretanto, diferenças estatisticamente significantes entre si. / The objective of this research was to compare the fracture resistance upon axial compressive loads of maxillary premolars endodontically treated with MOD preparations restored with ceramic (IPS-Empress 2) and ceromer (Targis) inlays cemented with three dual luting cements (Enforce, Variolink II and Panavia F). Sixty premolars free of caries or fractures, extracted for orthodontic purpose were selected. They were similarly distributed according with their bucco-lingual and mesio-distal dimensions in 6 groups determined by the combination of the restoring materials and luting agents. After cementation and thermocycling procedures, the teeth were fixed in a Universal Test Machine and subjected to an axial compressive load by action of a 8mm wide steel cylinder, at the speed of 0,5mm/min., contacting only the inner aspects of the buccal and lingual cusps. The results were, in decreasing order, as follows: Enforce (107,57kgf e 90,21kgf), Variolink II (86,44kgf e 84,07kgf) and Panavia F (82,43kgf e 76,73kgf), for inlays restored with Targis and IPS-Empress 2, respectively. They were found statistically significance differences between Enforce and Panavia F, independently of the restorative material. Considering the same luting agent, the results obtained with Targis restored groups were slightly superior of those restored with IPS-Empress 2, with no statistically significance difference.
24

Avaliação de satisfação dos usuários e qualidade das Próteses Parcial Removível instaladas na clínica de graduação da FOUSP entre 2010-2014 / Satisfaction evaluation and quality of removable partial dentures in the FOUSP undergraduate clinic between 2010-2014

Camargo, Marcelli Soares de Souza 06 June 2016 (has links)
O objetivo deste trabalho foi avaliar a qualidade e satisfação das próteses parciais removíveis instaladas na clínica da graduação da disciplina de prótese removível no período de 2010-2014. Os pacientes que participaram da clínica nesse período foram contactados por telefone e convidados a participar da clínica de retorno da disciplina e ao mesmo tempo verificar a qualidade das próteses e a satisfação do paciente. Do total de 284 próteses instaladas nesse período, 50 foram avaliadas neste trabalho. Os pacientes que aceitaram participar da pesquisa preencheram 4 questionários: 1) TCLE, 2) Mini-mental; 3) GOHAI e 4) Anamnese da Prótese. Das próteses presentes no estudo classificaram-se em Perfeitas (sem queixa) e Problemáticas (com queixa). Após preenchido os questionários, relacionou-se a queixa principal com arco restaurado, análise da oclusão presente na prótese em função na boca, qualidade da sela, higienização da prótese e o momento em que a falha é decorrente. Como conclusão, teve-se que a queixa \"soltar sozinha\" foi a de maior destaque e está relacionada ao momento da falha pós- instalação. As próteses mal adaptadas estão relacionadas com uma qualidade de vida prejudicada e isto reforça que os retornos periódicos para controle da prótese são fundamentais para o sucesso clínico da prótese. / The objective of this study was to evaluate the quality and satisfaction of removable partial dentures installed in removable prosthesis undergraduate clinic in the 2010-2014 period. Patients attending the clinic during this period were contacted by telephone and invited to participate in the discipline of clinical and return at the same time check the quality of prosthetics and patient satisfaction. Of the total of 284 implants installed during this period, 50 were evaluated in this study. Patients who agreed to participate completed 4 questionnaires: 1) TCLE, 2) MiniMental, 3)GOHAI and 4) anamnesis of the prosthesis. Prostheses present in the study were classified in Optimal (without complaint) and Problematic (complaining). Thus, the complaint related to restored arch, occlusal analysis in the function of the prosthesis, saddle quality, denture cleaning and the time when the failure is due. In conclusion, it was that the complaint \"drop alone\" was the most prominent and is related to the time of after installation failure. Poorly adapted prostheses are associated with impaired quality of life and this reinforces that the periodic returns to the prosthesis control are fundamental for clinical success of the prosthesis.
25

"Estudo comparativo da resistência à infiltração que diferentes materiais resinosos utilizados na cimentação de retentores intra-radiculares oferecem à passagem de fluidos que atravessam a dentina" / Comparative study of the infiltration resistance that different resinous materials used in intra-radicular retainers foundation offer to the fluids passage that cross through the dentine.

Mukai, Marcio Katsuyoshi 01 September 2005 (has links)
O Objetivo deste estudo é avaliar in vitro, a resistência que diferentes materiais resinosos têm a passagem de fluidos que atravessam a dentina na ausência de cemento radicular. Foram utilizados 60 dentes humanos cedidos pelo banco de dentes da FOUSP. Os dentes foram submetidos a tratamento endodôntico segundo a técnica de Paiva e Antoniazzi e armazenados a uma temperatura de 37°C em umidade 100% por 24 horas para o preparo do retentor intra -radicular respeitando o limite apical de 4 mm. Os retentores intra-radiculares foram modelados com resina tipo Duralay e fundidos com liga de prata e cimentados com os seguintes materiais: Oxifosfato de Zinco (SS White), Enforce (Dentsply), Panavia F (Kuraray) e Rely X (3M) . Após a cimentação, delimitou-se uma janela na região cervical da raiz onde o cemento foi removido com uma broca diamantada, a parte externa da raiz foi impermeabilizada com cianocrilato de etila e esmalte cosmético para posterior imersão em uma solução de azul de metileno a 1% por 48 horas. Decorrido este período, a camada impermeabilizante foi removida, os dentes foram desgastados no sentido mésio distal e avaliados com o programa Imagelab. A comparação da área impregnada pelo agente traçador na película dos cimentos, nos terços cervical e médio, revelou diferenças estatisticamente significantes (p < 0,01) do Panavia F (Kuraray) em relação aos outros três materiais, demonstrando a superioridade desse material no que se refere à impermeabilização do sistema de canais radiculares. Podemos concluir que dentre os materiais avaliados o cimento Panavia F (Kuraray) apresentou diferença estatisticamente significante, tanto para no segmento cervical quanto terço médio. / This study objective is to evaluate in vitro, the resistance that different resinous materials have through the fluids passage cross through the dentine in the absence of radicular cementum. 60 human teeth given by FOUSP bank of teeth were used. The teeth were submitted to endodontic treatment according to Paiva's and Antoniazzi´s technique and stored in a temperature of 37°C in humidity 100% during 24 hours for the preparation of the intra-radicular retainer, respecting the 4 mm apical limit. The intra -radicular retainers were modeled with Duralay resin type and melted with silver league and cemented with the following materials: Zinc Oxiphosfate (SS White), Enforce (Dentsply), Panavia F (Kuraray) and Rely X (3M). After the foundation, a window was delimited in the root cervical area where the cementum was removed with a diamond drill. The external part of the root was made waterproof with etile cyanocrylate and cosmetic enamel for subsequent immersion in a 1% blue methylen solution for 48 hours. Elapsed this period, the waterproof layer was removed, the teeth were consumed in the mesio-distal direction and appraised with the Imagelab software. The impregnated area by the tracer agent of the in the film of the cements comparison, in the cervical and medium thirds, revealed significant statistical differences (p <0,01) of Panavia F (Kuraray) in relation to the other three materials, demonstrating the superiority of that material in relationship to the radicular chanal “waterproofing" system. It’s possible to conclude that among the appraised materials, the Panavia F (Kuraray) cement presented significant statistical difference, in the cervical segment as well as the medium third.
26

Características da deglutição em idosos submetidos a diferentes estratégias de reabilitação oral protética / Characteristics of swallowing in elderly individuals submitted to different strategies for prosthetic oral rehabilitation

Totta, Tatiane 29 August 2008 (has links)
O objetivo deste estudo foi verificar se diferentes estratégias de reabilitação oral protética acarretam modificações nos achados clínicos e videoendoscópicos da deglutição em idosos. Métodos: participaram da pesquisa 42 idosos saudáveis com desempenho cognitivo adequado (26 mulheres e 16 homens, 60-82 anos), desdentados totais ou parciais, separados em três grupos segundo avaliação odontológica prévia: próteses parciais fixas ou removíveis (PP) (n = 15); próteses totais removíveis superior e inferior (PTR) (n = 15); e próteses totais removíveis superior e próteses totais fixas implanto-suportadas inferior (PTFIS) (n = 12). O grupo controle foi constituído de 15 idosos dentados totais (DT) (6 homens e 9 mulheres, 60-80 anos) que atenderam aos critérios de inclusão na amostra. Avaliaram-se as consistências sólida (pão), pastosa (10 ml) e líquida (10 ml). Para a avaliação clínica propôs-se uma classificação da gravidade da disfunção da deglutição orofaríngea, distribuída em cinco níveis. Na avaliação instrumental, da qual participaram 37 idosos, realizou-se teste de sensibilidade laringofaríngea, e classificou-se a gravidade do distúrbio de deglutição, de acordo com a escala de comprometimento funcional (gravidade) da deglutição após a VED, ordenada em graus de 0 à III. Para a análise comparativa entre os grupos em ambas as avaliações, e para comparação entre os níveis de comprometimento da deglutição, utilizou-se o Teste de Kruskal-Wallis, adotando-se o nível de significância inferior a 5%. Resultados: Os achados clínicos e videoendoscópicos da deglutição demonstraram não haver diferenças estatisticamente significantes (p>0,05) entre os grupos estudados, nas três consistências ofertadas. Especificamente na avaliação clínica, para a consistência pastosa o grupo DT apresentou maior prevalência de deglutição funcional, enquanto a disfagia orofaríngea moderada foi o padrão de maior ocorrência no grupo PTR (p<0,01). Para o sólido, os grupos de reabilitação oral demonstraram predomínio das disfagias (p<0,01) em relação à deglutição normal e funcional, sendo predominante a disfagia orofaríngea moderada para o grupo PTR (p<0,01). A VED demonstrou, para todos os grupos, que na deglutição de líquido houve distribuição semelhante entre os níveis, enquanto nas consistências sólida e pastosa encontrou-se predomínio de disfagia (p<0,01), havendo maior ocorrência da disfagia orofaríngea moderada (p<0,01) para o grupo PTR na consistência pastosa. O teste de sensibilidade laringofaríngea demonstrou que 19 (51,35%) indivíduos apresentaram alteração da sensibilidade, sendo 6 (40%) do grupo PP, 7 (63,63%) do grupo PTR e 6 (54,54%) do grupo PTFIS. Conclusão: Idosos saudáveis podem apresentar diferentes níveis de deglutição, havendo maior ocorrência de disfagia orofaríngea para as consistências pastosa e sólida, sendo que diferentes estratégias de reabilitação oral não resultam em modificações no padrão de deglutição desses sujeitos. / This study investigated if different strategies of prosthetic oral rehabilitation cause changes in the clinical and videoendoscopic findings of swallowing in elderly individuals. Methods: The study was conducted on 42 healthy elderly subjects with adequate cognitive performance (26 women and 16 men, 60-82 years), completely or partially edentulous, divided in three groups according to the previous dental evaluation: wearing fixed or removable partial dentures (RPD) (n = 15); wearing maxillary and mandibular removable complete dentures (RCD) (n =15); and wearing maxillary removable complete dentures and mandibular implant-supported fixed complete dentures (ISFCD) (n = 12). The control group was composed of 15 completely dentate elderly individuals (DT) (6 men and 9 women, 60-80 years) who met the inclusion criteria. Solid (bread), paste (10 ml) and liquid (10 ml) food textures were analyzed. Clinical evaluation was performed by classification of the severity of dysfunction of oropharyngeal swallowing, divided in five scores. The instrumental evaluation was applied to 37 elderly individuals, comprising the laryngopharyngeal sensitivity test for classification of the severity of the swallowing disorder according to the scale of functional impairment (severity) of swallowing after the VED, divided in scores 0 to III. Comparison between groups in both evaluations and between the scores of impairment of swallowing was performed using the Kruskal-Wallis test, at a significance level below 5%. Results: The clinical and videoendoscopic findings of swallowing revealed no statistically significant differences (p>0.05) between the study groups, for the three textures. Specifically with regard to the clinical evaluation for the paste texture, the DT group exhibited higher prevalence of functional swallowing, while the RCD group presented higher occurrence of moderate oropharyngeal dysphagia (p<0.01). With regard to the solid texture, the groups of oral rehabilitation presented predominance of dysphagia (p<0.01) in relation to normal and functional swallowing, with predominance of moderate oropharyngeal dysphagia for the RCD group (p<0.01). The VED demonstrated, for all groups, that the swallowing of liquid had a similar distribution between scores, while for the solid and paste textures there was predominance of dysphagia (p<0.01), with higher occurrence of moderate oropharyngeal dysphagia (p<0.01) for the RCD group for the paste texture. The laryngopharyngeal sensitivity test demonstrated that 19 (51.35%) individuals presented alterations in sensitivity, being 6 (40%) in the RPD group, 7 (63.63%) in the RCD group and 6 (54.54%) in the ISFCD group. Conclusion: Healthy elderly individuals may present different scores of swallowing, with higher occurrence of oropharyngeal dysphagia for the paste and solid textures; different strategies of oral rehabilitation did not cause changes in the pattern of swallowing of these individuals.
27

Estudo da resistência de quatro diferentes materiais utilizados na cimentação de pinos à infiltração lateral / Study of lateral infiltration resistance of four different materials used for posts cementing

Mukai, Marcio Katsuyoshi 12 August 2010 (has links)
A raspagem e o aplainamento radicular removem o cemento presente nesta área, o qual funcionaria como barreira de dentina contra a penetração de bactérias, toxinas e outros produtos vindos da superfície externa do dente. O objetivo deste estudo foi avaliar, in vitro, em dentes tratados endodonticamente, a resistência apresentada por diferentes materiais de cimentação na infiltração do azul de metileno, que poderia atravessar a dentina radicular, quando submetido a duas diferentes situações: a) raspagem e aplainamento do cemento radicular e b) remoção de cemento com pontas diamantadas. Para isso, utilizou-se 48 dentes humanos unirradiculares, cedidos pelo banco de dentes da FOUSP, tratados endodonticamente e preparados para receberem pinos. Estes foram modelados com resina acrílica para que, por meio de fundição, fossem obtidos os retentores intrarradiculares metálicos. Os dentes foram divididos em 4 grupos com 12 espécimes, e a cada um dos grupos, destinado um tipo de material diferente para a cimentação: Cimento de Zinco® (SS White, Rio de Janeiro, Rio de Janeiro, Brasil), Cimentos resinosos Panavia F® (Kuraray, Kurashiki, Okayama, Japan), Rely X U 100® (3M Dental, Seefeld, Alemanha) e Rely X Luting 2® (3M Dental, Sant Paul, Estados Unidos). Após esse procedimento, delimitaram-se duas janelas na região cervical da raiz, sendo que num dos lados o cemento foi removido com uma ponta diamantada e no lado oposto, com 40 golpes de cureta Gracey 5-6 (Neumar, São Paulo, São Paulo, Brasil) paralelos ao longo eixo do dente. Exceto nas regiões instrumentadas, o dente foi impermeabilizado externamente e exposto à solução de azul de metileno a 1% e pH 7,2 durante 48 horas. As amostras foram desgastadas no sentido do longo eixo até o maior diâmetro do pino e a área impregnada pelo corante foi digitalizada e mensurada com o programa Imagelab®. A comparação da área impregnada pelo agente traçador na película dos cimentos, nos terços cervical e médio, revelou diferenças estatisticamente significantes entre si (p < 0,05). No lado em que a dentina foi removida com broca, houve diferença estatisticamente significante quando os três materiais adesivos foram comparados com o Cimento de Zinco (SS White, Rio de Janeiro, Rio de Janeiro, Brasil). Na comparação entre os cimentos resinosos houve diferença estatisticamente significante (p<05) somente entre os cimentos Panavia F® (Kuraray, Kurashiki, Okayama, Japan) e Rely X U 100® (3M Dental, Seefeld, Alemanha) para o terço apical. Na superfície tratada com curetas periodontais, verificou-se diferença estatisticamente significante entre os grupos estudados (p < 0,05) apenas quando comparados o cimento Rely X U 100® (3M Dental, Seefeld, Alemanha) com Rely X Luting 2® (3M Dental, Sant Paul, Estados Unidos) para o terço cervical. Concluiu-se que para o tratamento com ponta diamantada, que os cimentos Panavia F® (Kuraray, Kurashiki, Okayama, Japan), Rely X U 100® (3M Dental, Seefeld, Alemanha) e Rely X Luting 2® (3M Dental, Sant Paul, Estados Unidos) têm comportamento semelhante para os terços cervical e médio, diferindo apenas no terço apical. Já para o tratamento com curetas periodontais, os cimentos Panavia F® (Kuraray, Kurashiki, Okayama, Japan), Rely X U 100® (3M Dental, Seefeld, Alemanha) e Rely X Luting 2® (3M Dental, Sant Paul, Estados Unidos) mostraram resultados similares para os terços médio e apical, diferindo apenas no terço cervical. / Scaling and root planning remove cementum present in this area, which would acts as a dentin barrier against penetration of bacterias, toxins and other products coming from the surface of the tooth. The objective of this study was to evaluate in vitro endodontically treated teeth, the resistance of different materials to methylene blue, which could cross the root dentin when submitted to two different situations: a) scaling and root planning b) removal of cementum with drills. It was used 48 human uniradicular teeth, assigned by FOUSPs teeth bank and were endodontically treated and prepared to receive pins. These were modeled with an acrylic resin in order to obtain the metallic intraradicular posts. The teeth were divided into four groups with twelve specimens. Each one of the groups received a different material for cementing: Cement of Zinc® (SS White, Rio de Janeiro, Rio de Janeiro, Brazil), Panavia F® Resin Cements (Kuraray, Kurashiki, Okayama, Japan), Rely X U 100® (3M Dental, Seefeld, Germany) and Rely X Luting 2® (3M Dental, Sant Paul, United States). After this procedure, it was delimited two windows in the cervical region of the root. One of the sides the cementum was removed with a diamond drill and on the other side, with 40 Gracey 5-6 curette strokes (Neumar, São Paulo, Brazil) parallel to the long axis of the tooth. Except on the instrumented regions, the tooth was externally sealed and exposed to a 1% methylen blue solution and pH 7.2 during 48 hours. The samples were scraped from the long axis until the largest post diameter. The impregnated area with the dye were scanned and measured with the Imagelab® program. The comparison between the impregnated area through the tracer agent on the cement film in the cervical and medium thirds revealed statistically significant differences (p<0,05). On the side where the dentin was removed with a drill, there was a statistically significant difference when the three adhesive materials were compared to the Zinc Cement (SS White, Rio de Janeiro, Rio de Janeiro, Brazil). In the comparison between the resin cements there was a statistically significant difference (p<0,05) only between the cements: Panavia F® (Kuraray, Kurashiki, Okayama, Japan) and Rely X U 100® (3M Dental, Seefeld, Germany) for the apical third. On the surface treated with periodontal curettes, it was identified a meaningful statistical difference between the studied groups (p<0,05) only when compared the cements: Rely X U 100® (3M Dental, Seefeld, Germany) with Rely X Luting 2® (3M Dental, Sant Paul, United States) for the cervical third. The conclusion was that when the treatment uses a drill, the cements: Panavia F® (Kuraray, Kurashiki, Okayama, Japan), Rely X U 100® (3M Dental, Seefeld, Germany) and Rely X Luting 2® (3M Dental, Sant Paul, United States) have similar behavior to the cervical and medium third. The unique difference comes from the apical third. On the other hand, the treatments using periodontal curettes, the cements Panavia F® (Kuraray, Kurashiki, Okayama, Japan), Rely X U 100® (3M Dental, Seefeld, Germany) and Rely X Luting 2® (3M Dental, Sant Paul, United States) resulted in similar results for the medium and apical thirds, only differing on the cervical third.
28

Efeito de soluções higienizadoras diárias em ligas de cobalto-cromo e resina acrílica termopolimerizável para prótese parcial removível. / Effect of denture cleansers on the properties of removable partial denture: in vitro study.

Felipucci, Daniela Nair Borges 09 October 2009 (has links)
A higienização das próteses removíveis é fundamental para a longevidade do tratamento e prevenção de patologias orais. O objetivo deste estudo foi avaliar o efeito de higienizadores de imersão nas superfícies da liga metálica e resina acrílica termopolimerizável de Prótese Parcial Removível (PPR), simulando 180 dias. Discos (12 mm x 3 mm) foram confeccionados com ligas metálicas de cobalto-cromo para PPR: Vera PDI® (VP) e DeguDent® (DD). Cada disco metálico foi incluído em mufla previamente preparada por matrizes de teflon (38 mm x 18 mm x 4 mm), incorporando-se o disco metálico à resina acrílica termopolimerizável. Os espécimes (n= 5) foram imersos nas seguintes soluções: água destilada (grupo controle - AD), hipoclorito de sódio 0,05% (HS), Cepacol® (cloreto de cetilpiridínio 0,005% - CE), Periogard® (digluconato de clorexidina 0,12% - PE), Corega Tabs® (peróxido alcalino e enzima - CT), Polident® (peróxido alcalino e enzima - PO) e Medical Interporous Dentures® (ácido cítrico - MI). Foram realizadas análise da estabilidade de cor por meio de espectrocolorímetro, análise visual da presença de manchas no metal, análise da perda de massa em balança de alta precisão e análise da rugosidade por meio de rugosímetro. Como estudo complementar, foram realizadas análises quantitativas da liberação de íons (cobalto e cromo) em cada solução com espectrômetro de massas e análises ópticas e qualitativas com microscópio eletrônico de varredura (MEV) e espectrometria de energia dispersiva de Raios-X (EDS). Os resultados de rugosidade, alteração de cor e massa apresentaram distribuição normal e homogênea, tendo sido submetidos à ANOVA e teste de Tukey (p< 0,05). Quanto à rugosidade (Ra&micro;m), não houve diferença estatisticamente significante entre as soluções e ligas tanto para o metal quanto para a resina. Com relação à alteração de cor da resina acrílica termopolimerizável (&Delta;E), houve diferença estatisticamente significante entre as ligas, soluções e na interação liga x solução. As soluções AD, CE e PE propiciaram menores valores que as demais. A resina associada à DD apresentou maior alteração de cor do que quando associada à VP (1,06 ± 0,51 e 0,51 ± 0,28, respectivamente). Com relação à presença de manchas no metal, o HS propiciou manchamento em 100% dos espécimes. O grupo MI/DD propiciou em 60% e o MI/VP em 40% dos espécimes. Quando avaliada a alteração de massa (g), as soluções CT e MI propiciaram maiores valores. Entre as ligas, a VP apresentou maior perda de massa. Com relação à liberação de íons cobalto e cromo, a solução de HS e a MI propiciaram maior liberação e quando comparadas as ligas, VP apresentou maior liberação de íons. Com o MEV pôde-se verificar que houve corrosão generalizada com o HS e por pites com a MI. Concluiu-se que as soluções CE, PE e PO não apresentaram efeitos deletérios podendo ser auxiliares à escovação para higienização de PPR. / The hygiene care of the removable dentures is required for the longevity of the treatment and prevention of oral diseases. The aim of this study was to evaluate the effect of denture cleansers on the surfaces of the alloys and heat-polymerized acrylic resin for removable partial denture (RPD), simulating a period of 180 days. Circular specimens (12 mm x 3 mm) had been fabricated with cobalt-chromium alloys: Vera PDI&trade; (VP) and DeguDent&trade; (DD). The cast specimens were centered in the moulds previously prepared by matrices of teflon (38 mm x 18 mm x 4 mm) and the acrylic resin was inserted. The specimens (n= 5) had been immersed in the following solutions: distilled water (control - DW), sodium hypochlorite 0.05% (SH), Cepacol&trade; (cetilpiridinium chloride 0.005% - CE), Periogard&trade; (chlorexidine gluconate 0.12% - PE), Corega Tabs&trade; (alkaline peroxide and enzyme - CT), Polident&trade; (alkaline peroxide and enzyme - PO) and Medical Interporous Dentures&trade; (citric acid - MI). The color stability was analyzed using a colorimeter, and the presence of tarnishes on the metal was performed by a visual analysis. The weight loss was measured with a precision balance and the surface roughness was analyzed with a surf-test analyzer. As complementary analyzes a quantitative study of ions release (cobalt and chromium) using inductively mass spectrometry and optical and qualitative analyses with scanning electron microscopy (SEM) associated to dispersive energy spectrometry were performed. The results of roughness, color stability and weight loss presented normal and homogeneous distribution and were submitted to ANOVA (p &le; 0.05) and Tukey test. There was no significant difference among the solutions and between the alloys for both metal and resin roughness (Ra &micro;m). The acrylic resin color stability (&Delta;E) was analyzed and showed significant difference among the solutions, alloys and interaction. AD, CE and PE solutions presented the lowest values of color changes. The resin associated to DD presented higher color change than when associated with the VP (1.06 ± 0.51 and 0.51 ± 0.28, respectively). The HS caused tarnishes on 100% of specimens. The MI/DD group provided 60% and the MI/VP in 40% of specimens. When was analyzed the mass loss (g), the solutions CT and MI had the higher values. Between the alloys VP presented higher weight loss. HS and MI presented greater ionic release and between the alloys, VP presented greater release. With the SEM it was possible observe the presence of widespread corrosion in the HS group and pites corrosion in the MI group. It was concluded that CE, PE, CT and PO solutions had no deleterious effects on the compounds of RPD and may be indicate as auxiliaries to brushing in the RPD hygiene care.
29

Avaliação da eficiência e capacidade mastigatória em pacientes com fissura labiopalatina reabilitados com prótese de recobrimento / Evaluation of chewing ability and efficiency of patients with cleft lip and palate rehabilitated with prosthesis overlay

Tavano, Rafael D'Aquino 15 April 2011 (has links)
Objetivou-se com este trabalho avaliar a capacidade e eficiência mastigatória de 37 pacientes com fissuras labiopalatinas, matriculados no Hospital de Anomalias Craniofaciais, Universidade de São Paulo (HRAC-USP) e 20 indivíduos não fissurados. O grupo 1 foi composto por 20 pacientes com fissura labiopalatina e dentição natural até pelo menos o 1º molar nos dois arcos dentários. O grupo 2 foi de 17 pacientes com fissura labiopalatina envolvendo rebordo, arco superior atrésico e com prótese parcial removível de recobrimento. Este grupo foi dividido nas condições sem a prótese (grupo 2a) e com a prótese (grupo 2b). O grupo 3 considerado grupo controle, foi formado por 20 indivíduos sem fissura, com dentição natural até pelo menos o 1º molar nos dois arcos dentários. Para a avaliação da capacidade mastigatória utilizou-se questionário padronizado, baseado na literatura, onde um único examinador limitou-se a explica-lo o questionário e não induziu as respostas. Para análise da eficiência mastigatória foram utilizadas amêndoas como alimento teste e sistema de tamises com peneiras e orifícios diferentes. Os resultados para a avaliação da capacidade e eficiência mastigatória indicaram que não houve diferença estatisticamente significante entre os grupos com fissura e com dentição natural (grupo 1 ) e grupo controle, sem fissura e dentição natural (grupo 3 ). Todavia, estes dois grupos apresentaram resultados melhores que o grupo com fissura e prótese parcial removível de recobrimento. Para os indivíduos com fissura e com prótese (grupo 2), a eficiência mastigatória foi melhor na condição com a prótese (grupo 2b) do que na condição sem a prótese grupo 2a). / This study aimed at evaluating the chewing ability and efficiency of 37 patients with cleft lip and palate attending the HRAC-USP and 20 individuals without clefts. Group1 comprised 20 patients with clefts presenting natural dentition at least up to the first molar in both dental arches. Group 2 was composed of 17 patients with clefts wearing removable partial dentures in at least one dental arch. This group was subdivided in group 2a comprised patients with clefts and without removable partial denture and group 2b, comprised patients with clefts and with removable partial denture. Group 3 (control) included 20 individuals without clefts presenting natural dentition at least up to the first molar in both dental arches. Evaluation of the chewing ability was performed by application of a literature-based standardized questionnaire in which only one examiner explained the questions and did not induce the responses. Analysis of chewing efficiency was conducted by utilization of almonds as test food and a system of sieves with different sizes and orifices. There was no statistically significant difference between groups 1 and 3 in relation to the chewing ability, but when compared groups 2b and 3, and groups 1 and 2b, there was statistically significant difference. Concerning evaluation of chewing efficiency, the individuals without clefts presented similar (statistically equal) outcomes compared to patients with clefts with natural dentition up to the first molar, with statistically better results when compared to those observed for patients with clefts wearing removable partial dentures, who were tested both with and without the prostheses. Patients with clefts with natural teeth presented better outcomes as patients wearing removable dentures either with or without their dentures in position. Comparison within the group of patients with clefts wearing removable partial dentures revealed that their chewing efficiency was statistically better when their dentures were in position.
30

Avaliação in vitro da precisão de três técnicas para moldagem do arco superior parcialmente edentado / Evaluation in vitro of the accuracy of three impression techniques for the partially edentulous upper arch

Bueno Junior, Eliseu Antonio 29 September 2005 (has links)
Este estudo serviu ao objetivo de avaliar a capacidade de reprodução da região do palato e o posicionamento de pilares em modelos de gesso de um arco superior parcialmente edentado, obtidos a partir de três técnicas de moldagem: 1) alginato em moldeira de estoque - AL; 2) pasta zincoeugenólica em moldeira individual, seguida de sobremoldagem com alginato em moldeira de estoque - MS e 3) silicone de condensação em moldeira de estoque pela técnica da dupla moldagem ou do reembasamento - SC. Os modelos de gesso testados foram obtidos a partir de moldagens executadas sobre modelo padrão metálico. Pontos representativos do perfil palatino, a distância relativa entre os pilares, bem como suas inclinações, foram mensurados com um aparelho de medição tridimensional de coordenadas e analisados quanto à sua fidedignidade em relação à morfologia do modelo padrão. Os resultados demonstraram que: 1) ocorreram distorções verticais positivas e negativas nos modelos produzidos pelas três técnicas, sendo que a técnica SC apresentou as maiores variações, predominantemente negativas, produzindo modelos com palato mais profundo quando comparados àqueles obtidos pelas técnicas M e A; 2) foram observadas distorções horizontais positivas e negativas nos modelos produzidos pelas três técnicas, com tendência de aumento das distâncias inter-pilares para as técnicas AL e SC e de encurtamento para a técnica MS; 3) os desvios angulares foram inexpressivos no comprometimento da inclinação axial dos pilares quando considerada a estabilização da estrutura metálica de uma prótese removível; 4) as distorções verificadas com as três técnicas estudadas estão dentro dos parâmetros de aceitabilidade clínica estabelecidos neste trabalho. / The objective of this study was to evaluate the reproduction potential of the palate area and the position of abutments in partially edentulous, upper stone casts produced with three impressions techniques: 1) irreversible hydrocolloid in stock tray - AL; 2) zinc oxide-eugenol paste in a custom tray with a pick-up impression of irreversible hydrocolloid - MS and 3) putty-wash condensation silicone in stock tray - SC. Representative points on the palatal surface and the relative distance between the abutments as well their inclination were measured with a three-dimensional coordinate measurement equipment and the data used to analyze the fidelity of the casts in relation to the original metal model. The results showed: 1) positive and negative vertical discrepancies on casts made from all impression techniques, with SC responsible for the highest variations (predominantly negatives) that rendered casts with a deeper palatal vault when compared to those obtained with AL and MS; 2) positive and negative horizontal discrepancies on casts produced from all impression techniques, with AL and SC tending to increase the distances between supports while MS seemed to decrease these distances; 3) the angular deviations observed represented no substantial compromise to the axial inclination of the abutment when considering the stability of the removable prosthesis framework; 4) the discrepancies evidenced with the three techniques were within the benchmark values for clinical acceptability initially established.

Page generated in 0.0839 seconds