• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 139
  • 13
  • 13
  • 13
  • 13
  • 12
  • 2
  • 1
  • 1
  • Tagged with
  • 139
  • 139
  • 103
  • 88
  • 78
  • 70
  • 58
  • 55
  • 42
  • 42
  • 40
  • 28
  • 24
  • 21
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Avaliação da influência da força de mordida na prótese parcial removível classe I mandibular associada ao implante osseointegrado, pelo método dos elementos finitos /

Lucas, Liliana Vicente Melo de. January 2003 (has links)
Orientador: Eduardo Piza Pellizzer / Resumo: A associação entre as próteses parciais removíveis e os implantes osseointegrados é, ainda, uma opção de tratamento muito pouco explorada na Odontologia reabilitadora moderna. Por isso, o objetivo deste estudo é avaliar, utilizando o método dos elementos finitos bidimensional, a distribuição de tensão nas estruturas de suporte da prótese parcial removível de extremidade livre (PPREL) associada a um implante osseointegrado de 10,0 x 3,75 mm (Sistema Branemark), localizado na região posterior do rebordo alveolar desdentado, atuando como suporte para a base da prótese. Para tanto, foram criados três modelos, os quais, em corte sagital, representam: modelo A (MA) - hemiarco contendo o dente natural 33 somente e o A rebordo desdentado distal; modelo B (MB) - semelhante ao MA, com uma PPREL convencional substituindo os dentes ausentes; modelo C (MC) - semelhante ao anterior, com um implante na região posterior do rebordo, sob a base da prótese. Com o auxílio do programa de elementos finitos ANSYS 5.4, os modelos foram carregados com forças verticais e oblíquas de 45º, tanto no sentido de mesial para distal como no sentido inverso, de magnitude de 50 N, em cada ponta de cúspide. A análise dos mapas de tensões permitiu concluir que: 1) a tendência de deslocamento no modelo com a PPR apoiada sobre implante é menor que no modelo com a prótese somente; 2) as forças oblíquas de 45º promovem uma tendência de deslocamento e valores de tensão maiores que a força vertical; 3) a força oblíqua de 45º, no sentido de mesial para distal, gera valores de tensão menores que a de distal para mesial e 4) a presença do implante osseointegrado, sob a base da prótese, promove alívio do dente suporte. / Abstract: The association among the removable partial dentures and the osseointegrated implants is still a non very explored option of treatment in the modern prosthetic dentistry. Because of this, the objective of this study is to evaluate, using the two-dimensional finite element analysis, the tension distribution in the support structures of the distal extension removable partial denture (RPD) associated with a 10.0 x 3.75 mm osseointegrated implant (Branemark System), located in the posterior area of the toothless alveolar edge, acting as support for the prosthesis base. Then, three plane strain models were created, represented in sagital cut: Model A (MA) - hemiarc containing the natural tooth 33 and the toothless alveolar edge; Model B (MB) - similar to MA, with a conventional RPD substituting the absent teeth; Model C (MC) - similar to the previous, with an implant in the posterior area of the edge, under the denture base. With the aid of the finite element program ANSYS 5.4, the models were loaded with vertical and 45º inclined forces, in both mesial and distal sides, with 50 N, on each peak point. The analysis of the tensions map allowed to conclude that: 1) the displacement tendency in the model with the RPD supported by the implant is smaller than the model with prosthesis only; 2) the oblique forces of 45º promote a displacement tendency and larger tension values than the vertical force; 3) the mesial to distal 45º oblique force generates smaller tension values than the one of distal to mesial and 4) the presence of the osseointegrated implant, under the denture base, promotes relief to the support tooth. / Mestre
42

Influência dos sistemas de retenção e da inclinação do rebordo residual em casos de próteses conjugadas Classe I mandibular : análise da distribuição das tensões pelo método da fotoelasticidade /

Ferraço, Renato. January 2009 (has links)
Resumo: A reabilitação de pacientes classe I de Kennedy mandibular através de Prótese Parcial Removível é de difícil resolução devido a diferença de resiliência existente entre o ligamento periodontal dos dentes suportes e a mucosa do rebordo residual. A inclinação do rebordo residual no sentido sagital pode influenciar na distribuição das tensões transmitidas pela incidência de cargas em próteses parciais removíveis de extremidade livre associadas a próteses parciais fixas. Na associação da prótese parcial removível com próteses parciais fixas, o profissional tem como alternativa aos grampos tradicionais, o uso de encaixes extra-coronários que podem melhorar a estética e o funcionamento biomecânico do conjunto. Desse modo, o objetivo desse estudo foi avaliar a característica da distribuição de tensões em próteses parciais removíveis mandibulares de extremidade livre associadas a próteses parciais fixas nos dentes suporte com diferentes sistemas de retenção: (1) grampo por ação de pontas; (2) sistema ASC-52; (3) sistema ERA; e (4) encaixe de semi-precisão Score-PD, pela metodologia da fotoelasticidade. E, analisar a distribuição de tensões em próteses parciais removíveis mandibulares de extremidade livre associadas a próteses parciais fixas nos dentes suporte com diferentes sistemas de retenção: (1) grampo por ação de pontas e (2) sistema ERA, variando duas inclinações de rebordo residual: (1) horizontal e (2) descendente distal. Cargas axiais de 100N foram aplicadas sobre os dentes das próteses parciais removíveis. As imagens das aplicações foram capturadas e a distribuição das tensões foi avaliada, pela formação das franjas fotoelásticas. No primeiro estudo, a prótese com encaixes de semi-precisão produziu os maiores níveis de tensão na região de ápice, entre as raízes dos últimos dentes suporte e na porção mais distal do rebordo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The rehabilitation of patients mandibular class I of Kennedy through Removable Partial Denture is difficult to solve because the difference in strength between the periodontal ligament of the abutment teeth and the residual ridge mucosa. The inclination of the residual ridge towards sagital may influence the distribution of stresses transmitted by the incidence of loads in distal extension removable partial dentures associated with fixed partial dentures. In association removable partial denture - fixed partial dentures, the professional has as alternative to the traditional clasps, the use of extra-coronary attachments that can improve the aesthetics and the biomechanics. Therefore, the objective of this study was to evaluate the characteristic distribution of tensions in mandibular distal extension removable partial dentures (1) "I" bar clasps, (2) ASC-52system, (3) ERA system, and (4) semi-precision Score-PD system, by the methodology of photoelasticity. And, analyze the distribution of tensions in mandibular distal extension removable partial dentures associated to the fixed partial dentures in the abutment teeth with different retention systems: (1) "I" bar clasps and (2) ERA system, ranging from two inclinations residual ridge: (1) horizontal and (2) distal descending. Axial loads of 100N were applied on the teeth of removable partial dentures. The images of the applications were captured and distribution of stress was assessed by the formation of the photoelastic fringes. In the first study, the prosthesis with semi-precision attachment produced the highest levels of tension in the region of apex, between the roots of the abutment teeth and in the more distal portion of the residual ridge. The prostheses with resilient attachments showed the largest fringes formations in the cervical-distal of the last abutment tooth. In the second study, horizontal ridge presented... (Complete abstract click electronic access below) / Orientador: Eduardo Piza Pellizzer / Coorientador: Stefan Fiuza de Carvalho Dekon / Banca: Marcelo Coelho Goiato / Banca: Fellippo Ramos Verri / Mestre
43

Desenvolvimento e validação de novas tecnologias para o ensino de preparos em prótese parcial fixa /

Gomes, Michelle de Sá dos Santos. January 2018 (has links)
Orientador: Alberto Noriyuki Kojima / Coorientador: Eduardo Shigueyuki Uemura / Banca: Alfredo Mikail Melo Mesquita / Banca: Rubens Nisie Tango / Resumo: O primeiro contato de alunos de graduação com a disciplina de Prótese Parcial Fixa ocorre em aulas teóricas e posteriormente em práticas laboratoriais. Na teoria os docentes utilizam de diversas formas para elucidar um preparo de Prótese Parcial Fixa, fotos e vídeos no passo a passo, guias de silicone, guias de redução, marcações coloridas e até mesmo demonstrações ao vivo. Utilizam- se desses métodos a fim de formar um conceito e fixar uma imagem de um preparo ideal obedecendo aos princípios mecânicos e biológicos das reduções estruturais em prótese fixa. O presente estudo teve como objetivo avaliar as principais dificuldades dos alunos de graduação nos preparos coronários em Prótese Parcial Fixa e sugerir ferramentas de ensino para auxiliar aluno e professor, a elucidar e calibrar os alunos nos desgastes coronários. Participaram da pesquisa ao todo 87 alunos matriculados do 3° ano integral, dos anos 2017 e 2018 da disciplina de Prótese Parcial Fixa, da graduação em Odontologia do ICT. Foi desenvolvido um aplicativo de celular com um banco de dados dos principais preparos coronários e com a possibilidade de comparação do preparo finalizado através de fotos. Também foram desenvolvidas, aplicadas e validadas 02 metodologias: Um manequim com esquema de cores que auxiliou o aluno a visualizar os preparos coronários e uma demonstração prática projetada comparou os métodos de ensino teórico e prático. 78,2% dos alunos relatam a quantidade de redução como a principal dificuldade. O... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The first contact of undergraduate students with the discipline of Partial Fixed Prosthesis occurs in theory classes and later in laboratory practices. In theory, teachers use a variety of ways to elucidate a Fixed Partial Prosthesis preparation, step-by-step photos and videos, silicone guides, reduction guides, color markers and even live demonstrations. These methods are used to form a concept and to fix an image of an ideal preparation obeying the mechanical and biological principles of the structural reductions in fixed prosthesis. The present study had as objective to evaluate the main difficulties of undergraduate students in coronary arteries in Fixed Partial Prosthesis and to suggest teaching tools to help students and teachers to elucidate and calibrate students in coronary wear. A total of 87 enrolled students from the 3rd full year, from the years 2017 and 2018 of the discipline of Partial Fixed Prosthesis, from the graduation in Dentistry from the ICT participated in the research. A cellular application was developed with a database of the main coronary preparations and the possibility of comparing the finished preparation with photos. Two methodologies were also developed, applied and validated: a color design mannequin that helped the student to visualize the coronary preparations and a practical demonstration designed to compare the methods of theory and practical teaching. 78.2% of the students report the amount of reduction as the main difficulty. The method ... (Complete abstract click electronic access below) / Mestre
44

Avaliação de tratamentos de superfície em diferentes sistemas cerâmicos e seu efeito na resistência de união a um cimento resinoso

Ribeiro, João Gustavo Rabelo [UNESP] 03 March 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-03-03Bitstream added on 2014-06-13T19:16:51Z : No. of bitstreams: 1 ribeiro_jgr_me_arafo.pdf: 3291389 bytes, checksum: 7433b8057e44c506b548538c7a3e997e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar o efeito de três tratamentos superficiais na resistência de união de um cimento resinoso a três cerâmicas dentais: Duceram Plus (DP), IPS Empress II (IPS) e In-Ceram Alumina (INC), e analisar a topografia superficial dessas cerâmicas submetidas aos mesmos tratamentos superficiais. Para o teste de resistência de união foram confeccionadas 18 amostras de cada material (7,5mm de diâmetro x 3,0mm de espessura), incluídas em resina acrílica e polidas até lixa nº 600. As amostras foram divididas em três grupos: a) jateamento com partículas de óxido de alumínio de 50 æm; b) condicionamento com ácido fluorídrico 10%; c) associação de a e b. As amostras foram lavadas e secas. A área de adesão da cerâmica foi delimitada com matriz metálica perfurada (5,0mm de diâmetro e 3,0mm de espessura). Foi aplicado silano, adesivo e cimento resinoso Variolink II, fotoativado por 40 segundos. As amostras receberam 1000 ciclos térmicos de 5 a 55°C. O ensaio de cisalhamento foi realizado em máquina de ensaios MTS 810, com célula de carga de 10 kN e velocidade de 0,5 mm/min. Para a topografia superficial foram confeccionados um coping de IPS, um do INC e uma coroa de DP, seguindo as recomendações dos fabricantes. Cada coping ou coroa foi cortado com disco diamantado em quatro partes: uma delas não recebeu nenhum tratamento, e as demais receberam um dos tratamentos acima descritos. Fotomicrografias foram obtidas por meio de microscopia eletrônica de varredura e a análise foi feita de acordo com a característica da superfície. Pode-se concluir que: o tratamento associado não ofereceu vantagens em relação ao condicionamento ácido, para os materiais DP e IPS; para o INC o tratamento associado não ofereceu vantagens em relação ao jateamento. A DP e o IPS apresentaram resultados melhores em relação ao INC, independentemente dos tratamentos... / The aim of this study was to evaluate the effect of three surface treatments on the shear bond strength of a resin luting cement to three ceramics materials: Duceram Plus (DP), IPS Empress II (IPS) and In-Ceram Alumina (INC), and to assess its surface topography after these treatments. Eighteen specims were fabricated to each material (7,5 mm in diameter x 3,0 mm in thickness), embebed in acrylic resin and ground up to 600 grit. The specims were randomly divided into 3 groups of 6 specims: (a) airborne particle abrasion with 50 æm aluminum oxide; (b) 10% hydrofluoric acid etching; (c) a and b treatments. The specims were cleaned and dried. Silane, adhesive and resin luting cement Variolink were applied in 5,0 mm in diameter and 3,0 mm height to ceramic surface and then light cured. All specims were termocycled (1000, 5-55°C). The shear bond strength was then measured in a testing machine MTS 810, at a crosshead speed of 0,5 mm/min. To asses the surface topography, one coping each of IPS and INC, and a DP crown were fabricated following the manufacturer's instructions. Each coping or crown was sectioned into 4 equal parts by a diamond disk. One part didn't receive any treatment, and the others, received treatments as above described. Photomicrographs were obtained by a SEM, and the superficial characteristic was described. In conclusion, the associate treatment didn't offer advantages in relation to the acid etching, for DP and IPS; for INC the associate treatment didn't offer advantages in relation to the airborne. DP and IPS presented the best results, independently of the superficial treatments. The photomicrographs showed compatible correlation of the superficial characteristic with the bond strength values.
45

Ruídos articulares em pacientes parcialmente desdentados (classe I ou II de Kennedy), antes e após a reposição dental com prótese parcial removível: avaliação através da eletrovibratografia

Baleeiro, Renata Porfíria [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2004Bitstream added on 2014-06-13T18:35:12Z : No. of bitstreams: 1 baleeiro_rp_me_araca.pdf: 915852 bytes, checksum: eda0ee966910bd8f3eec26386a5fc0fa (MD5) / Universidade Estadual Paulista (UNESP) / As alterações no aparelho estomatognático parecem se originar do desequilíbrio ortopédico da mandíbula. Uma das causas desse desequilibro é a ausência do suporte oclusal que poderia conduzir a uma posição côndilo-disco inadequada na fossa mandibular, diminuição da força dos músculos elevadores da mandíbula, lubrificação deficiente. Essas mudanças podem levar ao desalojamento do disco articular e, conseqüentemente, ao aparecimento de vibrações articulares. Dessa forma, este estudo busca identificar e quantificar a presença de vibrações por meio da eletrovibratografia em articulações temporomandibulares de pacientes Classe I e/ou II de Kennedy, no momento da consulta, um ano e dois anos após o tratamento oclusal. Os resultados indicaram que as vibrações articulares foram mais freqüentes no final da abertura e do fechamento bucal. Entretanto, as vibrações diminuíram no primeiro e no segundo ano, sendo que somente após dois anos a redução foi estatisticamente significante. A redução da vibração articular verificada é sugestiva de que o suporte molar evita o desalojamento do disco e permite um fortalecimento muscular. / The alterations in stomatognathic apparatus can be originate by orthopedical disbalance of the jaw. One of the causes of orthopedical disbalance is the absence of the occlusal support that could lead to a inadequate condyle-disk position related to mandibular fossa, weakness of mandibular elevators muscles, and joints temporomandibulars deficient lubrication. These alterations can contribute to displacement of the articular disk and consequently the forthcoming of articular vibrations. This aim of this study is to identify and quantify the presence of vibrations through the electrovibratography in temporomandibular joint of Kennedy class I and/or II patient, at the initial appointment, one year and two years after the occlusal treatment. The results indicated that the articular vibrations were more frequent at the end of the opening and buccal closing. However, the vibrations decreased in the first and second year. After second years the differences were statistically significant. The reduction of the articular vibration verified is suggestive that the support molar avoids the displacement of the disk and it allows a muscular invigoration.
46

Avaliação da adaptação marginal de copings cerâmicos obtidos por diferentes métodos de moldagem / Evaluation of the marginal adaptation of ceramic copings obtained by different molding methods

Pinto, Tatiana Saretta Ferreira [UNESP] 13 August 2018 (has links)
Submitted by Tatiana Saretta Ferreira Pinto (tatiorto13@hotmail.com) on 2018-10-11T15:04:44Z No. of bitstreams: 2 tese final para impressão.pdf: 1518062 bytes, checksum: f5bc8c4dd9de4a0b0698c8932e0aef20 (MD5) tese final para impressão.pdf: 1518062 bytes, checksum: f5bc8c4dd9de4a0b0698c8932e0aef20 (MD5) / Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2018-10-16T21:13:07Z (GMT) No. of bitstreams: 1 pinto_tsf_me_sjc.pdf: 1518062 bytes, checksum: f5bc8c4dd9de4a0b0698c8932e0aef20 (MD5) / Made available in DSpace on 2018-10-16T21:13:07Z (GMT). No. of bitstreams: 1 pinto_tsf_me_sjc.pdf: 1518062 bytes, checksum: f5bc8c4dd9de4a0b0698c8932e0aef20 (MD5) Previous issue date: 2018-08-13 / O objetivo desse estudo foi avaliar a adaptação marginal de copings cerâmicos obtidos pelos métodos de moldagem convencional e escaneamento. Os modelos foram separados em 3 grupos para avaliação e todas as coroas foram confeccionadas sobre um modelo mestre previamente fabricado em CoCr. Grupo 1: Com o auxílio de uma moldeira individual cilíndrica de acrílico foram reproduzidas 10 moldagens com silicona de adição (Panasil) no modelo mestre pela técnica de moldagem dupla e replicados dez modelos físicos em gesso pedra Fuji Rock.Sobre esses modelos foi realizado o enceramento dos copings, confecção dos sprues de cera e sobre eles foi realizada a injeção da cerâmica Grupo 2: foram realizadas 10 moldagens diretas com scanner extraoral (Swing Dental Scanner) no modelo mestre. As imagens foram obtidas através do software Exocad e copings em IPS-Emax CAD foram confeccionados em fresadora (Ceramill Motion 2) para posterior sinterização da cerâmica. Grupo 3: foram realizadas 10 moldagens diretas com scanner intraoral (CEREC Bluecam) no modelo mestre. As imagens foram obtidas através do software Exocad. Copings em IPS-Emax CAD foram confeccionados em fresadora (Ceramill Motion 2) para posterior sinterização da cerâmica. Os copings de cerâmica não foram cimentados no modelo mestre, apenas posicionados e mantidos com pressão constante de 1,4 a 1,5 kg durante a medição, com a ajuda de um delineador adaptado para esse trabalho, onde oito pontos eletivos foram usados como referência para medir a distância vertical entre a linha de término do modelo mestre e a linha de término dos copings. A margem em cada ponto foi medida 3 vezes com estéreomicroscópio Discovery V20 (ZEISS). A média de desadaptação marginal foi calculada e submetida ao teste de variância de um fator ANOVA com nível de significância de 5% e foram obtidos os seguintes resultados: 66,15µm para o grupo 1; 67,48µm para o grupo 2 e 72,91µm para o grupo 3,verificando assim que esses valores não diferem estatisticamente e todos estão dentro do limite de aceitabilidade clínica / The objective of the study was to evaluate the marginal adaptation of ceramic crowns obtained by conventional molding and scanning methods. The models were separated into 3 groups for evaluation and all the crowns were made on a master model previously manufactured in CoCr. For group 1: With the aid of a single cylindrical acrylic tray the master model was molded 10 times with Panasil in the master model by the technique of double molding and replicated ten physical models in stone gypsum Fuji Rock. On these models was done the waxing of the copings, making the sprues of wax and on them was carried out the injection of the ceramics In group 2, 10 direct impressions were performed with the Swing Dental Scanner (Korea) extra oral scanner in the master model. The images were obtained through the software Exocad (GmbH) and copings in IPS-Emax CAD were made in the Ceramill Motion 2 (Amanngirrbach) mill for subsequent sintering of the ceramics. In group 3, 10 direct impressions were performed with the CEREC Bluecam intraoral scanner (Sirona Dental Systems) in the master model. The images were obtained through the Exocad (GmbH) software. IPS-Emax CAD copings were made in the Ceramill Motion 2 (Amanngirrbach) mill for subsequent sintering of the ceramic. Ceramic copings were not cemented in the master model, only positioned and maintained with a constant pressure of 1.4 to 1.5 kg during the measurement, with the aid of an eyeliner adapted for this work, where eight elective points were used as reference to measure the vertical distance between the end line of the master model and the end line of the copings. The margin at each point was measured 3 times with stereo microscope Discovery V20 (ZEISS). The mean was calculated and submitted to the ANOVA variance test "with a significance level of 5% and the following results were obtained: 66.15μm for group 1; 67.48μm for group 2 and 72.91μm for group 3, thus verifying that these values do not differ statistically and all are within the limit of clinical acceptability.
47

Determinação da tensão de falha de lascamento da porcelana de cobertura em prótese livre de metal utilizando análise de imagem. / Determination of the failure stress of the porcelain chipping cover in metal free prosthesis using image analysis.

Silva, Elielson Nóbrega da [UNESP] 21 August 2018 (has links)
Submitted by Elielson Nobrega da Silva (nobrega_elielson@hotmail.com) on 2018-11-09T01:23:55Z No. of bitstreams: 1 Dissertação Ficha 08_11_1.pdf: 3453656 bytes, checksum: a1cff4951db4dde58ae977a59c6423b6 (MD5) / Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2018-11-19T18:56:22Z (GMT) No. of bitstreams: 1 silva_en_me_sjc.pdf: 3453656 bytes, checksum: a1cff4951db4dde58ae977a59c6423b6 (MD5) / Made available in DSpace on 2018-11-19T18:56:22Z (GMT). No. of bitstreams: 1 silva_en_me_sjc.pdf: 3453656 bytes, checksum: a1cff4951db4dde58ae977a59c6423b6 (MD5) Previous issue date: 2018-08-21 / A introdução da zircônia na Odontologia deu-se pela necessidade de melhores propriedades mecânicas dos materiais cerâmicos, pois com a crescente demanda estética, os cerâmicos tornaram-se materiais de largo uso, devido às suas propriedades estéticas e mecânicas. Em busca dessas propriedades, vários estudos analisaram a taxa de sobrevivência de restaurações zircônia-porcelana, relatando como uma das causas de falha a fratura precoce da porcelana de cobertura e o aumento significativo nos relatos clínicos de lascamento da porcelana de recobrimento aplicada sobre "coping" de zircônia. Diante desse problema, o objetivo deste trabalho foi determinar a tensão de falha no lascamento a partir de casos de clínicos e experimentais pertinentes a esse fenômeno em próteses fixas livres de metal .Foram coletados dados de artigos dos últimos 15 anos, por meio das bases de dados Pubmed e Google Schoolar, sendo selecionados para essa revisão os que obtiveram melhor abordagem do assunto, dando ênfase às possíveis causas de falhas nas restaurações cerâmicas dos casos clínicos e os ensaios realizados, visando um melhor entendimento desse fenômeno, via análise quantitativa e qualitativa, para melhor utilização e aproveitamento desse material na Odontologia. Para determinação da tensão de falha, foi empregada a mecânica da fratura linear elástica e determinado o fator de correção da trinca com base nas dimensões da trinca.Com a presente pesquisa, nota-se que amplitude de tensão influencia no processo de fratura, embora não tenha apontado exatamente para a causa da fratura. No entanto, pode-se inferir que uma baixa taxa de sobrevivência está relacionada a um grande defeito que, por sua vez, necessitou de uma sobrecarga para conduzir o processo de lascamento. Portanto, melhorias no processo de fabricação podem otimizar as características do material e sua aplicação final para suportar as tensões, a fim de aumentar a taxa de sobrevivência. / The introduction of zirconia in dentistry was due to the need for better mechanical properties of ceramic materials, because of an increasing aesthetic demand. Ceramics became widely used materials due to their aesthetic and mechanical properties. Aiming at these properties, several studies have analyzed the survival rate of zirconia-porcelain restorations, reporting as one of the causes of failure. Early porcelain fracture coverage and a significant increase in clinical reports of veneering porcelain applied over "coping "of zirconia. In view of this problem, the objective of this work was to determine the failure causes of chipping from clinical and experimental cases associated to this phenomenon in fixed metal free prostheses. Data from articles of the last 15 years were collected through the Pubmed and Google Schoolar databases. Those who obtained the best approach to the subject were selected for this analysis, emphasizing the possible causes of failures in the ceramic restorations of the clinical cases and the tests performed. Aiming for a better understanding of this phenomenon, via quantitative and qualitative analysis, to better use this material in dentistry. To determine the failure causes, linear elastic fracture mechanics were used and the crack correction factor was determined based on the crack dimensions. With the present research, it is noticed that stress amplitude influences in the fracture process, although it has not pointed exactly the cause of the fracture. However, it can be inferred that a low survival rate is related to a large defect, this in turn needed an overload to conduct the chipping process. Therefore, the manufacturing process can improve the characteristics of the material and its final application to withstand the stresses in order to increase the survival rate.
48

Estudo comparativo in vitro da resistência à remoção de grampos circunferenciais aplicados sobre dentes íntegros e restaurados com resina composta

Melo Filho, Antonio Braulino de [UNESP] 30 June 1994 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:22:56Z (GMT). No. of bitstreams: 0 Previous issue date: 1994-06-30. Added 1 bitstream(s) on 2015-12-10T14:29:10Z : No. of bitstreams: 1 000026434.pdf: 4352939 bytes, checksum: f59dc1edfd8a91ab4f0abc5ee063d699 (MD5) / Foi realizado um estudo experimental in vitro para investigar o comportamento da força necessária para o deslocamento de grampos circunferenciais de P.P.R. em dois grupos de corpos de prova: 1 com regime de trabalho do terminal retentivo sobre esmalte 2 com regime de trabalho do terminal retentivo sobre resina composta Para tal finalidade foi idealizado um dispositivo, construído a partir de uma máquina de costura de marca Elgin que tinha por objetivo simular repetidamente o movimento de introdução e remoção de grampos circunferenciais sobre os corpos de prova. O dispositivo contava ainda com uma plataforma para fixar os corpos de prova e permitir aferições, um contador de ciclos e um dinamometro. Os corpos de prova foram obtidos a partir da inclusão em gesso de dentes naturais extraídos, íntegros, do grupo dos molares, cujas áreas retentivas eram em esmalte natural ou construídas artificialmente, por adição de resina composta. Os grampos foram obtidos a partir de esculturas com resina acrílica e cera e fundidos em liga de cobalto cromo. A resina composta usada foi de última geração, do tipo monomodal, fotopolimerizável e retida no esmalte através de ataque ácido. Os testes foram realizados em meio aquoso, estabelecendo-se para cada corpo de prova cinco mil ciclos. Foram feitas verificações a cada cem ciclos até dois mil e a cada duzentos ciclos até o total de cinco mil. Os resultados mostraram que as variações na quantidade de força necessária para remover os grampos dos corpos de prova durante todo o período dos ensaios foi desprezível, sem significância, tanto para aqueles com áreas retentivas em esmalte como naqueles com áreas retentívas artificialmente feitas com resina composta / An experimental study was undertaken in arder to find out lhe behavior of the required force to yield dislodgement of circumierential clasps of removable partial dentures ou two groups of samples. 1 with retentive terminais engaging and acting ou enamel 2 with retentive terminais engaging on enamel and acting on composite resm With this aim a device was designed based on a sewing machine (brand name Elgin) that could repeatedly simulate lhe introduction-removal movement of circunferencial clasps ou the samples. ln addiction the device had a platform to sustain the samples and permit measurements, a cycle counter and a dynamometer. The samples were constructed by inclusion in dental stone of extracted natural molar teeth whose retentive areas were ou natural enamel or composite resin addictions.The clasps were fabricated from wax ups of resin and wax and were cast with chromium cobalt alloy. The composite resin used was one of the last generation, monomodal type, photopolymerized and binded to the enamel by the acid etching technique. Tests were carried out in aqueous enviroment. Is was established a maximum of 5.000 cycles for each of the samples. Observatins were made from 100 to 100 cycles until 2.000 and from 200 to 200 cycles to 5.000. Results showed that variations in the amount of the required force for dislodgement of the clasps from the samples during the test periods had no significancy eather to those with retentive areas on the enamel or to those with retentive fabricated with addictions of composite resin
49

Avaliação da resistência flexural de materiais restauradores provisórios resinosos /

Machado, Carolina Ellen Spínola January 2018 (has links)
Orientador: Andréa Abi Rached Dantas / Resumo: O objetivo do estudo foi avaliar a resistência flexural de materiais restauradores resinosos provisórios (Systemp Onlay, Bifix Temp, Provyl Master F, Fill Magic e Clip F) após a fotopolimerização com sistema de fotoativação LED-laser: Radii-Cal (SDI, São Paulo, SP, BR). A resistência flexural demonstrada pelos materiais restauradores provisórios Provi Master F (Wilcos), Systemp (Ivoclair) e Fill Magic (Coltene) foi similar (p >0,05) e maior que a demonstrada pelos materiais restauradores BiFix (Voco) e Clip F (Voco) (p < 0,05). Por outro lado, a resistência flexural apresentada pelo BiFix e Clip F foi semelhante entre si (p > 0.05). Concluimos assim que os materiais Provi Master F, Systemp e Fill Magic são materiais de melhor escolha quando necessitamos de uma resistência maior às forças oclusais. / Abstract: The objective of this study was to evaluate the flexural strength of temporary resin restorative materials (Systemp Onlay, Bifix Temp, Provyl Master F, Fill Magic e Clip F) after photopolymerization with LED-laser photoactivation system: : Radii-Cal (SDI, São Paulo, SP, BR). The flexural strength demonstrated by the provisional restorative materials Provi Master F (Wilcos), Systemp (Ivoclair) e Fill Magic (Coltene) was similar (p >0,05) and greater than that demonstrated by restorative materials BiFix (Voco) e Clip F (Voco) (p < 0,05). On the other hand, the flexural strength demonstrated by Be Fil and Clip F were similar among themselves (p > 0.05). We conclude that the materials Provi Master F, Systemp and Fill Magic are materials of better choice when we need a greater resistance to occlusal forces. / Mestre
50

Avaliação da resistência flexural de materiais restauradores provisórios resinosos / Evaluation of the flexural strength of temporary resin restorative materials

Machado, Carolina Ellen Spínola 17 May 2018 (has links)
Submitted by Carolina Ellen Spinola Machado (carolina.machado@unesp.br) on 2018-07-17T17:50:57Z No. of bitstreams: 1 Tese Mestrado Carol Spinola Correção Final.pdf: 1288993 bytes, checksum: 2bda3149606dd9c289679698a83d6cbc (MD5) / Approved for entry into archive by Ana Cristina Jorge null (anacris@fclar.unesp.br) on 2018-07-17T18:28:03Z (GMT) No. of bitstreams: 1 machado_ces_me_arafo_int.pdf: 1335157 bytes, checksum: c25b86d1526dd6b3333d99b75d0e04b1 (MD5) / Made available in DSpace on 2018-07-17T18:28:03Z (GMT). No. of bitstreams: 1 machado_ces_me_arafo_int.pdf: 1335157 bytes, checksum: c25b86d1526dd6b3333d99b75d0e04b1 (MD5) Previous issue date: 2018-05-17 / O objetivo do estudo foi avaliar a resistência flexural de materiais restauradores resinosos provisórios (Systemp Onlay, Bifix Temp, Provyl Master F, Fill Magic e Clip F) após a fotopolimerização com sistema de fotoativação LED-laser: Radii-Cal (SDI, São Paulo, SP, BR). A resistência flexural demonstrada pelos materiais restauradores provisórios Provi Master F (Wilcos), Systemp (Ivoclair) e Fill Magic (Coltene) foi similar (p >0,05) e maior que a demonstrada pelos materiais restauradores BiFix (Voco) e Clip F (Voco) (p < 0,05). Por outro lado, a resistência flexural apresentada pelo BiFix e Clip F foi semelhante entre si (p > 0.05). Concluimos assim que os materiais Provi Master F, Systemp e Fill Magic são materiais de melhor escolha quando necessitamos de uma resistência maior às forças oclusais. / The objective of this study was to evaluate the flexural strength of temporary resin restorative materials (Systemp Onlay, Bifix Temp, Provyl Master F, Fill Magic e Clip F) after photopolymerization with LED-laser photoactivation system: : Radii-Cal (SDI, São Paulo, SP, BR). The flexural strength demonstrated by the provisional restorative materials Provi Master F (Wilcos), Systemp (Ivoclair) e Fill Magic (Coltene) was similar (p >0,05) and greater than that demonstrated by restorative materials BiFix (Voco) e Clip F (Voco) (p < 0,05). On the other hand, the flexural strength demonstrated by Be Fil and Clip F were similar among themselves (p > 0.05). We conclude that the materials Provi Master F, Systemp and Fill Magic are materials of better choice when we need a greater resistance to occlusal forces.

Page generated in 0.0565 seconds