• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 139
  • 13
  • 13
  • 13
  • 13
  • 12
  • 2
  • 1
  • 1
  • Tagged with
  • 139
  • 139
  • 103
  • 88
  • 78
  • 70
  • 58
  • 55
  • 42
  • 42
  • 40
  • 28
  • 24
  • 21
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Avaliação da distorção linear em estruturas métalicas de próteses sobre implantes: fundidas em peça única e em segmentos soldados a laser e através da soldagem convencional (brasagem)

Costa, Elza Maria Valadares da [UNESP] 29 June 2001 (has links) (PDF)
Made available in DSpace on 2018-07-27T18:25:55Z (GMT). No. of bitstreams: 0 Previous issue date: 2001-06-29. Added 1 bitstream(s) on 2018-07-27T18:29:54Z : No. of bitstreams: 1 000138043.pdf: 3009336 bytes, checksum: 4461e732807121379a46347a761b1f11 (MD5) / Próteses sobre implantes osseointegrados requerem critério de fabricação preciso devido a ausência de tecidos periodontais que compensam erros menores de relacionamento. Para tanto, em um arco mandibular edêntulo, construído em aço-cromo, foram fixados cinco análogos de pilares de implante, paralelos entre si, com distância de 10mm medidos de centro a centro. Sobre estes foram parafusados novos cilindros de ouro, com torque de 10 N/cm. Então foram executadas 15 sobre-estruturas metálicas que foram divididas: GC - Adaptação passiva dos cilindros de ouro; GM - monobloco GB - segmentos soldados por brasagem e, GL - segmentos soldados a laser. Observou-se as estruturas parafusadas com parafusos sempre novos sob microscópio de mensuração. A medição foi realizada na vestibular e lingual da interface cilindro/análogo e dados anotados em tabela apropriada. Para o eixo y, a técnica de soldagem a laser (Media=12,41 e Dp=11,12) produziu menos distorção significativamente do que a técnica de brasagem (Media=23,06 e Dp=13,31) seguida pela técnica de monobloco (Media=39,83 e Dp=21,88) p= 0.05. Para o eixo x, somente o grupo Monobloco apresentou diferença significativa para as demais técnicas (Média= 45,66 e Dp=21,56) / Prosthesis above osseointegrated implants requires an accurate criterion of manufacture. So, in an edentulous mandibular arch, constructed with chromium steel, five analogous were fixed, parallels, with distance of 10 mm measured of center to center. Above these gold cylinders were positioned and screwed with a torque of 10 N/m. In the next follow, fifteen over structures were fabricated and divided in tour groups: CG - Passive adaptation of gold cylinders; MG - Monobloc casting; BG - Casting in segments after brasing; LG - Casting in segments after laser welding. The structures were observed with measures microscope and the data noted in specific table. The measures done in two points (left and right) in the buccal and lingual surfaces of the interface of the cylinder/analogous set in the x and y-axis. The statistics analysis (ANOVA) showed significant statistics differences, on y-axis, among groups: LG group was superior to BG and this was superior to MG group and on x-axis only MG was superior to others groups (when we studied distortion.)
52

Análise comparativa das tensões e deformações entre próteses implantossuportadas de três elementos com dois ou três pilares /

Nishioka, Gabriela Nogueira de Melo. January 2016 (has links)
Orientador: Guilherme de Siqueira Ferreira Anzalone Saavedra / Banca: Alberto Noriyuki Kojima / Banca: José Scarso Filho / Resumo: O objetivo deste estudo foi avaliar as tensões e deformações in vitro, por meio da fotoelasticidade e da extensometria, em próteses parciais fixas implantossuportadas de três elementos variando o número de pilares: dois e três. O primeiro bloco de poliuretano (modelo mestre 1) recebeu três implantes e o segundo (modelo mestre 2) recebeu dois implantes, todos de hexágono externo. Em seguida, os modelos mestre foram duplicados em resina fotoelástica. Pilares protéticos microunit foram conectados aos implantes com torque de 20 Ncm. Sobre os pilares protéticos dos modelos mestre foram parafusados cilindros plásticos, que receberam estruturas em padrões de resinas, os quais foram fundidos em liga de Ni-Cr (n=10). Quatro extensômetros foram colados na superfície de cada bloco de poliuretano, tangenciando os implantes. Nos modelos mestre e nos modelos fotoelásticos, cada estrutura metálica foi parafusada sobre os pilares protéticos com torque de 10 Ncm. Os dados obtidos na extensometria foram submetidos aos testes estatísticos RM ANOVA e Tukey (5%). As franjas isocromáticas obtidas nos modelos fotoelásticos após cada condição de carga foram registradas com uma câmera digital, visualizadas em um programa de computador e comparadas qualitativamente. Resultados: Houve uma diferença estatística significante entre a quantidade de suporte de uma prótese fixa (p=0,001). Os resultados revelaram que três implantes apresentaram uma melhor distribuição das cargas em qualquer ponto analisado e ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The present study used photoelastic and strain gauge analysis to compare stress and microstrain to perform an in vitro evaluation of the effect of the numbers of support in a implant-supported fixed partial prostheses with tree elements. The first polyurethane block (master model 1) will contain three implants and the second block (model 2) two of them, all implants have a external hexagon. Then, the master models were duplicated in photoelastic resin. Microunit abutments were connected to the implants and received a 20 Ncm torque. Over the master model plastic prosthetic cylinders were screwed the abutments that received standard patterns cast in Ni-Cr alloy (n=10). Four strain gauges (SG) were bonded in the surface of the block, tangentially to the lateral implants. On the master model and photoelastic model, each metallic structure were screwed onto the abutments with a 10 Ncm torque. The data obtained from the strain gauge were analyzed statistically by RM ANOVA and Tukey's test, with a 5% conventional level of significance. The isochromatic fringes obtained in the photoelastic models after each load condition were recorded with a digital camera, visualized with software to facilitate qualitative analysis. Results: There was statistically significant differences in support of FPD( p=0,001).The results demonstrated that 3 implants has higher stress distribution and in the pontic of FPD we found higher stress (2326,95µε in 2 implants and 1006,57µε in 3 implants).In photoelastic images, 3 implants presented better stress distribution than 2 implants. Conclusions: Both methods found similar results. This study suggests ....(Resumo completo, clicar acesso eletrônico abaixo) / Mestre
53

Comportamento biomecânico de implantes retos e angulados sobre cargas axiais e não axiais por análise de elementos finitos e extensometria linear /

Tribst, João Paulo Mendes. January 2017 (has links)
Orientador: Renato Sussumu Nishioka / Banca: Alexandre Luiz Souto Borges / Banca: Francisley Ávila Souza / Resumo: Este trabalho buscou estudar as microdeformações geradas ao redor de implantes de hexágono externo durante carregamentos axiais e não axiais, variando-se a angulação dos implantes, utilizando a análise por elementos finitos e a extensometria linear como ferramentas. Inicialmente modelos 3D de diferentes próteses fixas foram construídos a fim de se permitir uma correlação dos resultados encontrados no modelo simplificado com o modelo anatômico e assim validar a geometria da prótese utilizada no estudo. Após a confirmação dos resultados de tensão similar entre as próteses na região dos implantes e do bloco, o modelo da prótese simplificada foi definida como válida. Em seguida, um modelo de bloco de poliuretano foi criado e duplicado. Implantes com conexão de hexágono externo (HE) foram modelados e em um bloco representados perpendiculares à superfície enquanto que em outro bloco foram colocados com inclinação de 17°. Foram modelados também intermediários do tipo mini pilar cônico retos e angulados conforme a inclinação dos implantes. Por último, foi utilizado o modelo de supraestrutura previamente validada para ambos os grupos, na qual a carga foi incidida. Todos os constituintes foram considerados perfeitamente simétricos, sólidos, isotrópicos. Os modelos receberam cargas de 300 N/cm em pontos axiais e não axiais através do software de análise por elementos finitos para se verificar a tensão máxima principal e as microdeformações. Em seguida, através da análise experimental de... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract:This Work aimed to study the microstrains generated around external hexagon implants during axial and non-axial loads, varying the angulation of the implants, using finite element analysis and linear strain gauge as tools. Initially 3D models of different fixed prostheses were constructed in order to allow a correlation of the results found in the simplified model with the anatomical model and thus validate the geometry of the prosthesis used in the study. After confirming the results of similar stress between the prostheses in the implants and the block region, the simplified prosthesis was defined as valid. After, a polyurethane block model was created and duplicated. Implants with external hexagon connection (HE) were modeled and inserted perpendiculary into one block while in another block, were placed with the inclination of 17 °. Straight and angled mini conical abutments were also modeled according to the inclination of the implants. Finally, the supra-structure previously validated for both groups was used, through which the load was affected. All constituents were considered perfectly symmetrical, solid, and isotropic. The models received a load of 300 N / cm in axial and non-axial points through the finite element analysis software, to verify the maximum principal stress and microstrains. Then, through the experimental analysis of strain-gauge, two polyurethane blocks were prepared and received three HE implants each, as well as respective mini tapered pillars according to the inclination of the installed implants. Then, a metallic superstructure, identical to the computational model, was cast in Ni-Cr and screwed onto the implants with torque of 10 N / cm. The load of 300 N / cm was applied for 10 seconds at axial and non-axial points. To measure the microstrains, four extensometers were glued on the surface of....(Resumo completo, clicar a acesso eletrônico abaixo) / Mestre
54

Prótese parcial removível de extremidade livre associada a um implante osseointegrado : influência do ligamento periodontal na distribuição interna das tensões /

Archangelo, Carlos Marcelo January 2005 (has links)
Resumo: Em função da adoção de hipóteses simplificadoras nos estudos através do método dos elementos finitos (MEF), os dados sobre a menor solicitação das estruturas de suporte na associação da prótese parcial removível de extremidade livre (PPREL) com um implante osseointegrado são inconclusivos. Assim, foi objetivo do presente estudo avaliar, através do MEF bidimensional, a distribuição interna das tensões nas estruturas de suporte da PPREL associada a um implante osseointegrado, em função da reprodução homogênea e não-homogênea do ligamento periodontal (LP). Para isso, 6 modelos (M) foram criados no programa AutoCAD 2005 (Autodesk Inc.; USA), representando: MA - hemiarco contendo somente o dente 33 e o rebordo desdentado para distal; MB - semelhante ao A, com uma PPREL substituindo os dentes ausentes; MC - semelhante ao B, com um implante (Sistema Bränemark - 3,75 mm x 10,0 mm) na região retromolar suportando a base da prótese; MD, ME e MF semelhantes aos modelos A, B e C, respectivamente, com exceção do LP, que foi modelado de forma não-homogênea, com a representação de 4 conjuntos de fibras: fibras da crista, horizontais, oblíquas e apicais. Após isso, os modelos foram exportados para o programa de elementos finitos ANSYS 8.0, e carregados com forças estritamente verticais de 50N em cada ponta de cúspide, fracionadas em 5 pontos de 10N. Os mapas gerais de tensões evidenciaram máxima e mínima concentração de tensões de (em MPa): MA (58,976 e 0,0045); MB (77,863 e 0,0551); MC (207,195 e 0,0057); MD (110,33 e 0,0137); ME (191,36 e 0,0044) e MF (326,60 e 0,0076), com deslocamento máximo de (mm): MA (0,0631); MB (0,1263); MC (0,1142); MD (0,2709); ME (0,1960) e MF (0,2019). (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The application of many hypotheses in a finite element analysis (FEA) has been critical to obtain precise results in the removable partial denture treatment associated with an osseointegrated implant. In view of that, the purpose of the present study was to evaluated, through 2-D finite element analysis, the stress distribution in the support structures of a free-end saddle removable partial denture (RPD) associated with an osseointegrated implant, in function of the homogenous and non-homogenous condition for the periodontal ligament. For this, 6 models (M) were created in the AutoCAD software (Autodesk Inc.; USA), representing: MA - hemiarch contain only the natural tooth (33) and edentulous space in the posterior region; MB - similar to MA, with an RPD replacing the absent teeth; MC - similar to MB, with an osseointegrated implant (Branemark System - 3.75 x 10.00 mm) positioned in a posterior region in order to support the RPD base; MD, ME and MF - identical to MA, MB and MC, respectively; however, in these models, the periodontal ligament was considered an non-homogenous structure by the incorporation of four fibers groups in a sagital plane: alveolar crest fibers, horizontals, oblique, and apical fibers. After this, the models were exported to the finite element program (ANSYS 8.0) and loaded with verticals forces (50N) in each cusp. The results showed maximum and minimum stress (MPa): MA (58.976 and 0.0045); MB (77.863 and 0.0551); MC (207.195 and 0.0057); MD (110.33 and 0.0137); ME (191.36 and 0.0044) and MF (326.60 and 0.0076). The maximum displacement (mm) was: MA (0.0631); MB (0.1263); MC (0.1142); MD (0.2709); ME (0.2019) and MF (0.2019). (Complete abstract click eletronic address below) / Orientador: Eduardo Passos Rocha / Coorientador: João Antônio Pereira / Banca: Eduardo Piza Pellizzer / Banca: Wellington Cardoso Bonachela / Banca: Eduardo Passos Rocha / Mestre
55

Estudo da densidade óptica e da resistência à flexão de três pontos em corpos-de-prova fundidos com a liga metálica High Bond (Co-Cr), com secções vertical 90°, diagonal 45° e diagonal 22,5°, soldados pelas técnicas convencional e TIG /

Pereira, Leonardo Viana. January 2012 (has links)
Orientador: Stefan Fiuza de Carvalho Dekon / Banca: Marco Polo Marchese / Banca: Gilberto Aparecido Coclete / Resumo: O sucesso das próteses sobreimplantes está diretamente relacionado ao grau de adaptação dos componentes protéticos aos implantes. Com a finalidade de se obter um assentamento passivo entre a prótese e os implantes, as estruturas metálicas são confeccionadas inicialmente segmentadas e, posteriormente, soldadas clinicamente para minimizar as distorções do processo de fundição. O sistema TIG (Tungsten Inert Gas) é definido como uma soldagem de arco elétrico, estabelecido entre um eletrodo não consumível à base de tungstênio e a peça a ser soldada. O propósito desse estudo foi, através do uso da densidade óptica e de um teste mecânico de resistência à flexão de 3 pontos, analisando a rigidez do material e a tensão de flexão, verificar o comportamento de dois sistemas de soldas odontológicas: convencional e TIG, realizadas em diferentes angulações (90°, 45° e 22,5°) de secções das porções a serem soldadas, comparando-os a um grupo fundido em monobloco (controle), em uma liga de Co-Cr. Os grupos foram comparados entre si quanto à densidade óptica, rigidez, tensão de flexão. A análise dos resultados obtidos possibilitou as seguintes conclusões: 1. Em relação à análise dos dados da densidade óptica mostrou que o grupo controle apresentou-se mais eficientes, estatisticamente significantes, quando comparadas aos grupos do sistema de solda TIG; não houve diferenças estatisticamente significantes entre as diferentes angulações num mesmo sistema de soldagem, porém quando comparados os sistemas de soldagem numa mesma angulação, o grupo de 22,5°-solda convencional teve resultado melhor, estatisticamente significante, que o 22,5°-solda TIG; 2. Em relação à rigidez (modulo de elasticidade), houve diferença estatisticamente significante apenas quando se comparou os corpos com angulação de 90° com diferentes soldas, tendo resultados maiores com ... / Abstract: The success of the prosthesis over implant is directly related to the adaptation degree of the prosthesis components to implants. Aiming to obtain a passive fit between the prosthesis and the implant, initially the metal structures are segmented and later are clinically welded to minimize the distortions of the casting process. The TIG system (Tungsten Inert Gas) is defined as a welding of an electric arc, established between a non consumable electrode based on tungsten and the part to be welded. The purpose of this study was to use the optical density and a mechanical test of 3 points flexion endurance, to analyze the stiffness of the material and the bending stress and to verify the behavior of two systems of dental welders: conventional and TIG performed at different angles (90º, 45º e 22, 5º) of the sections of the portions to be welded, and compare them to a group fused on monobloc (control) in an alloy of Co-Cr. The groups were compared on optical density, stiffness and bending stress. Analysis of the results made possible the following conclusions: 1. The analysis of the data showed that the optical density of the control group was more efficient, statistically significant, when compared to the groups with TIG welding system; there were no statistical differences between the different angles on the same welding system, although when comparing the welding systems in the same angle, the group of 22,5º- conventional welding had better result than the 22,5º - TIG welding, this difference was statistically significant; 2. There was statistical significant difference regarding the stiffness (modulus of elasticity) only when it was compared the bodies with the 90º angle with different welds, the higher results were with the conventional welding; 3. The results of the... / Mestre
56

Perfil das condições sistêmicas e bucais de usuários de próteses removíveis atendidos em um Serviço de Medicina Bucal /

Sposto, Maria Regina. January 1996 (has links)
Resumo: A presença de doenças sistêmicas, uso de medicamentos, e uso de próteses removíveis, entre outros fatores, podem alterar o equilíbrio fisiológico da cavidade bucal favorecendo o estabelecimento de diversas alterações e/ou patologias bucais. Assim, o estudo das prevalências destes fatores, nos pacientes odontológicos, tornam-se importantes pois devem ser considerados para elaborar o diagnóstico e definir a conduta terapêutica. Com o objetivo de delinear um perfil, avaliamos os prontuários de 500 usuários de próteses removíveis atendidos no Serviço de Medicina Bucal da Faculdade de Odontologia de Araraquara - UNESP. Analisamos os dados referentes a: características da população e das próteses removíveis, prevalência das doenças sistêmicas, uso de medicamentos e diagnóstico final das patologias ou alterações bucais. Os resultados obtidos nos permitem concluir que a maioria (74%) dos usuários de próteses removíveis eram mulheres brancas; metade da população pertencia a faixa etária de 41 a 60 anos e, quase a metade (49,2%) usava a combinação de prótese total superior e inferior. As doenças sistêmicas foram relatadas por 57,2% da amostra e a prevalência maior foi de doenças do sistema cardiovascular (25,4%). A maioria (60,4%) da população relatou uso de medicamentos e, dentre os mais freqüentes, a prevalência maior foram dos cardiovasculares (26,4%). A prevalência de patologias ou alterações bucais foi de 99,6%, sendo as relacionadas ao uso de próteses removíveis as mais freqüentes. Dentre estas, a candidose crônica atrófica ocorreu em 81,8% da população estudada e a hiperplasia fibrosa em 29,2%. / Abstract: Systemic diseases, the use of drugs and removable prosthetic appliance wearing, among others conditions, can influence the oral health, promoting the development of various oral mucosal disorders. Thus, the study of those informations on the dental patients becomes important and must be considered to estabilish the diagnosis and therapeutic management. The aim of this study was to provide descriptive epidemiologic information. For that task we have collected and analysed data from 500 files of patients, which are wearers of removable prosthetic appliances who attended at the Oral Medicine Service of Araraquara Dental School - UNESP. The results provide information about characteristics of the population and their removable appliances, prevalences of systemic diseases, use of drugs and diagnosis of oral diseases. The results allowed us to draw a profile of the population, concluding that the majority (74%) of the removable appliances wearers were white women, half of the sample with age between 41 to 60 years and almost half using an association of complete maxillary denture and complete mandibular denture. The health questionnaire indicated 57.2% of the population with systemic diseases, and the highest prevalence was of cardiovascular diseases (25.4%).The majority of the sample (60.4%) reported the use of drugs and the cardiovascular drugs were the more frequent (26.4%). The prevalence of oral diseases was 99.6%, the ones which were related with removable prosthetic were the most frequent. Among these, chronic atrophic candidosis was diagnosed in 81.8% of the sample and fibrous hyperplasia in 29.2%.
57

Avaliação da precisão de aquisição de dados nos Sistemas CAD/CAM : desadaptação marginal horizontal /

Lopes, Leonardo Ferreira de Toledo Piza. January 2015 (has links)
Orientador: Eduardo Piza Pellizzer / Coorientador: José Vitor Quinelli Mazaro / Banca: Fellippo Ramos Verri / Banca: Sandra Lúcia Dantas de Moraes / Resumo: Objetivo: O objetivo deste estudo foi avaliar a adaptação marginal horizontal de infraestruturas de próteses fixas confeccionadas pelo sistema CAD-CAM com três diferentes sistemas de aquisição de dados. Material e Métodos: Foram confeccionados 50 corpos de prova divididos em 5 grupos, sendo eles, Convencional (Ni-Cr); GI: iTero; GII: CerecBluecam/fresadora industrial; GIII: 3S; GIV: CerecBluecam/ fresadora Sirona, todos com n=10. Os corpos de prova foram numerados e randomizados, realizou-se análise da desadaptação marginal horizontal, esta dividida em positiva para sobre-contorno e negativa para subcontorno. Resultados: A análise intra-examinador revelou não haver diferença estatística entre os dois períodos de análise (t pareado=0.019; p=0.985). Em relação as desadaptações de sobre-contorno (valores positivos) podemos analisar que o grupo controle (Convencional) apresentou estatisticamente (p <0.001) menores valores de desadaptação (82 μm) quando comparado com o grupo CAD/CAM (144 μm). Ao comparar o sistema intra/extra-oral pode-se observar que o grupo intra-oral (iTero) apresentou melhores resultados, sendo essa diferença estatisticamente significante (p <0.001) que o extra-oral (3s). Já avaliando a diferença entre um sistema aberto com um fechado foi observado que o sistema aberto apresentou estatisticamente menor desadaptação (p<0.001). Quando avaliou-se a "quebra" de um sistema fechado (Cerec BlueCam) para sua fresagem a nível industrial notou-se que há desvantagens em tal procedimento, pois houve estatisticamente maiores desadaptações no grupo da "quebra" do sistema (p<0.001). Em contra partida nenhuma diferença estatisticamente significante foi encontrada em todas as análises quando se comparou desadaptação por sub contorno. Significância: Avaliando a discrepância... / Abstract: Objective: The aim of this study was to evaluate the horizontal marginal fit of frameworks produced by CAD/CAM systems with 3 different data acquisition. Material and Methods: We fabricated 50 frameworks divided into 5 groups, Conventional (Ni- Cr); GI: iTero; GII: CerecBluecam/industrial milling; GIII: 3S; GIV: CerecBluecam/Sirona, all with n = 10. We numbered the specimens and analyzed them randomly. Results: Intra-observer analisys indicated no statistically significant difference (paired t-test=0.019; p=0.985). In relation to the overextended horizontal marginal discrepancy (Positive Values) can analyze that the Control group (Conventional) had significantly (p < 0.001) minor discrepancy values (82 μm) when compared to the CAD / CAM group (144 μm). When comparing the systems intra/extra oral can be appreciated that the intra oral group (Itero) presented statistically best results when comparing(p < 0.001) that the extra oral ( 3s ). Evaluating the difference between the open system with closed was observed that the open system had statistically smaller misfit (p < 0.001). Evaluating the "broke" of a closed system (Cerec Bluecam) your industrial milling had statistically (p < 0.001) worse adaptation when compared to the laboratorial milling. About the under extended marginal discrepancy, in all analysis there was not found statistically significant difference. Significance: Assessing the horizontal marginal discrepancy was possible to note that in relation to the overextended the control group had statistically better results than the CAD/CAM systems, however the Cerec Bluecam system by sirona milling had better results than all CAD/CAM system and also the control group. There was no difference between the under extended misfit and all analysis / Mestre
58

Determinação da resistência à flexão de ligas odontológicas, utilizadas em prótese parcial fixa e prótese sobre implante, soldadas por brasagem e a laser /

Dinato, José Cícero. January 1999 (has links)
Orientador: Marco Antonio Bottino / Banca: Paulo Afonso Burmann / Banca: Maximiliano Píero Neisser / Resumo: O objetivo deste trabalho foi determinar a resistência à flexão de sessenta corpos-de-prova cilíndricos, obtidos a partir de quatro ligas metálicas utilizadas em prótese parcial fixa e prótese sobre implante, disponíveis no mercado brasileiro (Co-span 13.5, Stabilor G, Deva 4 e Palliag M) medindo 25 mm de comprimento e 3 mm de diâmetro. Cinco corpos-de-prova de cada liga foram fundidos em monobloco, cinco soldados por brasagem e cinco a laser Nd-YAG, Dessa forma, obtiveram-se 15 corpos-de-prova para cada liga metálica, divididos em três grupos. No grupo I, os corpos-de-prova foram fundidos em monobloco; no grupo 2, soldados por brasagem; no grupo 3, soldados a laser. Após a conclusão dos corpos-de-prova, os três grupos foram submetidos a um ensaio de resistência flexural, em uma máquina de testes lnstron. O ensaio consistiu em submeter os corpos-de-prova a uma carga ao seu centro, com as suas extremidades apoiadas em dois cilindros separados por uma distância de 20 mm, de modo que sofressem a ação e reação da carga em apenas três pontos. A velocidade de aplicação da carga foi de 0,5 mm/min, com uma célula de carga de 500 kg. Os resultados numéricos obtidos foram submetidos à Análise de Variância e ao teste de Tukey, ao nível de 5% de probabilidade. Em vista dos resultados obtidos, conclui-se que o maior valor numérico da resistência flexural foi encontrado para a liga Co-span 13.5, seguido do Deva 4, para os grupos de soldagem a laser e monobloco. O material Palliag M apresentou valores estatisticamente semelhantes para os três grupos. A liga Stabilor G apresentou os melhores resultados no método por brasagem / Abstract: The mechanic properties of brazed joints compared with castings performed in monoblocks have been exhaustingly evaluated. The use of laser in Dentistry opened a new and promising field to study this type of fusion. The purpose of this study was to determine the flexural resistance of four types of metal alloys used in fixed partial prosthodontics (Co-span 13.5, Stabilor G, Deva 4 and Palliag M). Fifteen test specimens with 3 mm diameter and 25mm length were obtained by casting for each alloy, and divided in three groups (monoblocks, brazing and laser welding), totaling sixty cylindrical specimens. The specimens were submitted to GLP/O2 torch welding and Nd-YAG laser welding performed with a specific laser equipment (Laser 2002, Dentaurum, Germany). The results were compared with tests performed in monoblocks of these same materials. To determine the flexural resistance, an universal testing machine (Instrom, model 4301), with a 500 Kg maximum capacity was used. The results were statistically analyzed using an ANOVA and Tuckey'.s test in a 5% degree of probability. The results showed that the highest numeric value of flexural resistance was found with the Co-Span alloy, followed by Deva 4, for both laser welding and monoblock groups. Palliag M showed statistically similar values for the laser welding, brazing and monoblock groups, whereas Stabilor G presented its highest values in brazing / Mestre
59

Avaliação da influência da inclinação do rebordo e localização do implante na associação de uma PPR classe I mandibular ao implante pelo método dos elementos finitos /

Cunha, Lígia Del'Arco Pignatta. January 2007 (has links)
Orientador: Eduardo Piza Pellizzer / Banca: Paulo Renato Junqueira Zuim / Banca: Regina Tamaki / Banca: Humberto Gennari Filho / Banca: Fellippo Ramos Verri / Resumo: A resolução protética dos arcos com extremidades livres através da associação entre prótese parcial removível e implantes osseointegrados é, ainda, uma opção pouco utilizada na clínica odontológica. Grande parte dos trabalhos existentes aborda essa associação apenas no rebordo com inclinação horizontal, apesar da importância da conformação do rebordo na dissipação das forças atuantes e no grau de estabilidade da prótese. Desse modo, o propósito dessa pesquisa é avaliar, através do método dos elementos finitos bidimensional, a distribuição de tensão e deslocamento nas estruturas de suporte de uma prótese parcial removível de extremidade livre (PPREL) associada ou não a um implante osseointegrado de 10,0 x 3,75 mm (Sistema Bränemark) com sistema ERA de retenção, em diferentes formatos de rebordo alveolar e localização do implante. Foram elaborados 16 modelos mandibulares, os quais, sob corte sagital, representavam hemiarcos com rebordos horizontal (MA ao MD), descendente distal (ME ao MH), ascendente distal (MI ao ML) ou descendente-ascendente (MM ao MP); dente natural 33; PPREL convencional, com placa distal no 33 ou apoio incisal na distal do 33, ou PPREL retida por implante, com sistema ERA, localizado na região anterior ou posterior do rebordo. Com o auxílio do programa de elementos finitos ANSYS 9.0, os modelos foram carregados com forças estritamente verticais de 50 N em cada ponta de cúspide. A análise dos Mapas permitiu concluir que o posicionamento do implante de maneira anterior associado à PPREL com placa distal, foi a melhor associação para preservar as estruturas de suporte (dente remanescente e rebordo alveolar residual) quanto à solicitação das mesmas nos diferentes tipos de rebordos alveolares estudados, tanto em relação à tendência ao deslocamento, quanto em relação à distribuição de tensões. / Abstract: The prosthetic solution of arches with distal extensions by associating removable partial dentures with osseointegrated implants is still an infrequently used option in clinical dentistry. Therefore, the purpose of this research was to assess, by means of the two-dimensional finite element method, the stress distribution and support structure displacement of a distal extension removable partial denture (DERPD) associated with an osseointegrated implant of 10.0 x 3.75 mm, (Bränemark System) with the ERA retention system in different shapes of alveolar ridges and implant locations. Sixteen mandibular models were prepared in sagittal cut, which represented hemiarches with horizontal (MA to MD), distal descendant (ME to MH), distal ascendant (MI to ML) or descendant-ascendant (MM to MP) ridges; natural tooth 33; conventional DERPD, with distal plate on 33 or incisal support on the distal of 33, or implant retained DERPD, with the ERA system, located in the anterior or posterior region of the ridge. With the aid of the finite element program ANSYS 9.0, the models were loaded with strictly vertical forces of 50 N on each cusp tip. Analysis of the Maps allowed the conclusion that placement of the implant in the anterior position associated with the DERPD with a distal plate, was the best association for preserving the abutment structures (remaining tooth and residual alveolar ridge) with regard to the demand on them in the different types of alveolar ridges studied, considering both the trend towards displacement and stress distribution. / Doutor
60

Extensometria : estudo das deformações ao redor de três implantes cone morse, com posicionamento linear, sob carga axial /

Abreu, Celina Wanderley de. January 2009 (has links)
Orientador: Renato Sussumu Nishioka / Banca: Renato Sussumu Nishioka / Banca: José Claudio Martins Segalla / Banca: Eduardo Shigueyuki Uemura / Resumo: O objetivo desse estudo foi avaliar a aplicação de carga e distribuição das microdeformações ao redor de implantes com conexão protética cone morse. Três implantes foram inseridos num bloco de poliuretano e pilares microunit foram instalados nos implantes com torque de 20 Ncm. Três coifas usinadas foram adaptadas nos pilares para configurar a supraestrutura protética (n=5) e comparar com as supra-estruturas obtidas com coifas plásticas. Quatro extensômetros foram colados na superfície superior do bloco. Uma carga vertical estática de 30 Kg foi aplicada em cinco pontos das supra-estruturas. Os registros obtidos dos extensômetros foram submetidos ao teste estatístico ANOVA e Tukey (α=5%). As medidas derivadas dessa simulação revelaram que durante a aplicação de carga: (1) existiu uma relação direta do local de aplicação e na distribuição da microdeformação ao redor dos implantes; (2) não existiu diferença na microdeformação entre coifas plásticas e usinadas. / Abstract: The aim of this study was to evaluate the load transfer and strain distribution by an implant-supported fixed partial prosthesis. Three implants Morse Taper were inserted in a polyurethane block and abutments microunit were installed on the implants with a torque of 20 Ncm. Plastic cylinders and prefabricated cylinders were adapted on abutments to fabricate the framework (n=5). Four strain gauges were attached on the superior surface of the block and then each framework was tight on the abutments with a torque of 10 Ncm and vertical load of 30Kg was applied to five points on the framework. The data obtained in the strain gauge analysis were submitted to the statistical tests ANOVA and Tukey (α=5%). The measurements derived from this simulation revealed that: (1) there was a direct proportion between the strain distribution in the metal framework and stresses created in the supporting structure around the implants; (2) there was not a strain difference between plastic and prefabricated cylinders during the load transfer / Mestre

Page generated in 0.067 seconds