• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 139
  • 13
  • 13
  • 13
  • 13
  • 12
  • 2
  • 1
  • 1
  • Tagged with
  • 139
  • 139
  • 103
  • 88
  • 78
  • 70
  • 58
  • 55
  • 42
  • 42
  • 40
  • 28
  • 24
  • 21
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Sistemas CAD/CAM : avaliação da precisão de aquisição de dados /

Mello, Caroline Cantieri de. January 2014 (has links)
Orientador: Eduardo Piza Pellizzer / Coorientador: José Vitor Quinelli Mazaro / Banca: Fellippo Ramos Verri / Banca: Ricardo Alexandre Zavanelli / Resumo: Objetivo: O objetivo deste estudo foi avaliar a adaptação marginal de infraestruturas de próteses fixas confeccionadas pelo Sistema CAD/CAM com três diferentes sistemas de aquisição de dados. Material e Métodos: Confeccionaram-se 50 corpos de prova; Convencional (Ni-Cr) (n = 10), GI: iTero (n = 10), GII: CerecBluecam/fresadora industrial (n = 10), GIII: 3S (n = 10) e GIV: CerecBlueCam/Sirona (n = 10). Os corpos de prova foram numerados e randomizados, realizou-se análise da desadaptação marginal vertical. Resultados: A análise intra observador indicou que não houve diferença estatisticamente significante (teste t pareado, p = 0.822) no período antes e depois das análises. O sistema convencional (321 μm) apresentou maior desadaptação quando comparado com o sistema CAD/CAM (89 μm) (p<0.001). O sistema intra oral (iTero) apresentou menor índice de desadaptação marginal, quando comparado com o sistema extra oral (3S), (p<0.001). O sistema aberto apresentou maior índice de desadaptação marginal (114 μm) quando comparado com intra oral (iTero), sendo p<0.001. Além disto, no sistema convencional, observou-se que os pré-molares apresentaram índice de desadaptação maior quando comparado (361 μm) com o molar (283 μm) (p<0.001), porém no sistema CAD/CAM não houve diferença estatisticamente significante na comparação de dentes pré-molares (93,7 μm) e molares (84,9 μm). Significância: O sistema CAD/CAM pode atuar mais favoravelmente, reduzindo o índice de desadaptação marginal, quando comparado com o sistema convencional de confecção de próteses dentárias. O sistema intra oral (iTero) comportou-se melhor quando comparado com os demais sistemas. / Abstract: Objective: The aim of this study was to evaluate the marginal fit of frameworks produced by CAD/CAM systems with three different data acquisition. Material and Methods: We fabricated 50 frameworks: conventional (Ni-Cr) (n = 10), GI:iTero (n = 10), GII:CerecBluecam/industrial milling (n = 10), GIII:3S (n = 10), and GIV:CerecBlueCam/Sirona (n = 10). We numbered the specimens and analyzed them randomly. Results: Intra-observer analysis indicated no statistically significant difference (paired t-test, p = 0.822) before and after the analysis. The conventional system (321 μm) showed greater misfit than the CAD/CAM (89 μm) (p<0.001) system. The intraoral system (iTero) showed a lower rate of marginal misfit than the extra-oral system (3S), (p<0.001). The open system presented a higher marginal discrepancy (114 μm) than intraoral (iTero), with p<0.001. Moreover, in the conventional system, premolars (361 μm) showed a higher index of misfit than molars (283 μm) (p<0.001), but for the CAD/CAM system, there was no statistically significant difference between premolars (93.7 μm) and molars (84.9 μm). Significance: The CAD/CAM system can to act more favorably reducing the rate of marginal discrepancy than the conventional impression system of dental prosthesis. The intra oral system (iTero) was better than other systems. / Mestre
62

Estudo comparativo in vitro da resistência à remoção de grampos circunferenciais aplicados sobre dentes íntegros e restaurados com resina composta /

Melo Filho, Antonio Braulino de. January 1994 (has links)
Orientador: João Vieira de Moraes / Banca: José Eduardo Junho de Araújo / Banca: Rogério Lacaz Netto / A BFO possui a versão preliminar da tese, com alterações, sob o título: Estudo comparativo in vitro do comportamento, quanto à força necessária à remoção, de grampos circunferenciais de Prótese Parcial Removível com regimes de trabalho sobre esmalte e sobre um tipo de resina composta. / Resumo : Foi realizado um estudo experimental in vitro para investigar o comportamento da força necessária para o deslocamento de grampos circunferenciais de P.P.R. em dois grupos de corpos de prova: 1 com regime de trabalho do terminal retentivo sobre esmalte 2 com regime de trabalho do terminal retentivo sobre resina composta Para tal finalidade foi idealizado um dispositivo, construído a partir de uma máquina de costura de marca Elgin que tinha por objetivo simular repetidamente o movimento de introdução e remoção de grampos circunferenciais sobre os corpos de prova. O dispositivo contava ainda com uma plataforma para fixar os corpos de prova e permitir aferições, um contador de ciclos e um dinamometro. Os corpos de prova foram obtidos a partir da inclusão em gesso de dentes naturais extraídos, íntegros, do grupo dos molares, cujas áreas retentivas eram em esmalte natural ou construídas artificialmente, por adição de resina composta. Os grampos foram obtidos a partir de esculturas com resina acrílica e cera e fundidos em liga de cobalto cromo. A resina composta usada foi de última geração, do tipo monomodal, fotopolimerizável e retida no esmalte através de ataque ácido. Os testes foram realizados em meio aquoso, estabelecendo-se para cada corpo de prova cinco mil ciclos. Foram feitas verificações a cada cem ciclos até dois mil e a cada duzentos ciclos até o total de cinco mil. Os resultados mostraram que as variações na quantidade de força necessária para remover os grampos dos corpos de prova durante todo o período dos ensaios foi desprezível, sem significância, tanto para aqueles com áreas retentivas em esmalte como naqueles com áreas retentívas artificialmente feitas com resina composta / Abstract: An experimental study was undertaken in arder to find out lhe behavior of the required force to yield dislodgement of circumierential clasps of removable partial dentures ou two groups of samples. 1 with retentive terminais engaging and acting ou enamel 2 with retentive terminais engaging on enamel and acting on composite resm With this aim a device was designed based on a sewing machine (brand name Elgin) that could repeatedly simulate lhe introduction-removal movement of circunferencial clasps ou the samples. ln addiction the device had a platform to sustain the samples and permit measurements, a cycle counter and a dynamometer. The samples were constructed by inclusion in dental stone of extracted natural molar teeth whose retentive areas were ou natural enamel or composite resin addictions.The clasps were fabricated from wax ups of resin and wax and were cast with chromium cobalt alloy. The composite resin used was one of the last generation, monomodal type, photopolymerized and binded to the enamel by the acid etching technique. Tests were carried out in aqueous enviroment. Is was established a maximum of 5.000 cycles for each of the samples. Observatins were made from 100 to 100 cycles until 2.000 and from 200 to 200 cycles to 5.000. Results showed that variations in the amount of the required force for dislodgement of the clasps from the samples during the test periods had no significancy eather to those with retentive areas on the enamel or to those with retentive fabricated with addictions of composite resin / Mestre
63

Avaliação de satisfação dos usuários e qualidade das Próteses Parcial Removível instaladas na clínica de graduação da FOUSP entre 2010-2014 / Satisfaction evaluation and quality of removable partial dentures in the FOUSP undergraduate clinic between 2010-2014

Marcelli Soares de Souza Camargo 06 June 2016 (has links)
O objetivo deste trabalho foi avaliar a qualidade e satisfação das próteses parciais removíveis instaladas na clínica da graduação da disciplina de prótese removível no período de 2010-2014. Os pacientes que participaram da clínica nesse período foram contactados por telefone e convidados a participar da clínica de retorno da disciplina e ao mesmo tempo verificar a qualidade das próteses e a satisfação do paciente. Do total de 284 próteses instaladas nesse período, 50 foram avaliadas neste trabalho. Os pacientes que aceitaram participar da pesquisa preencheram 4 questionários: 1) TCLE, 2) Mini-mental; 3) GOHAI e 4) Anamnese da Prótese. Das próteses presentes no estudo classificaram-se em Perfeitas (sem queixa) e Problemáticas (com queixa). Após preenchido os questionários, relacionou-se a queixa principal com arco restaurado, análise da oclusão presente na prótese em função na boca, qualidade da sela, higienização da prótese e o momento em que a falha é decorrente. Como conclusão, teve-se que a queixa \"soltar sozinha\" foi a de maior destaque e está relacionada ao momento da falha pós- instalação. As próteses mal adaptadas estão relacionadas com uma qualidade de vida prejudicada e isto reforça que os retornos periódicos para controle da prótese são fundamentais para o sucesso clínico da prótese. / The objective of this study was to evaluate the quality and satisfaction of removable partial dentures installed in removable prosthesis undergraduate clinic in the 2010-2014 period. Patients attending the clinic during this period were contacted by telephone and invited to participate in the discipline of clinical and return at the same time check the quality of prosthetics and patient satisfaction. Of the total of 284 implants installed during this period, 50 were evaluated in this study. Patients who agreed to participate completed 4 questionnaires: 1) TCLE, 2) MiniMental, 3)GOHAI and 4) anamnesis of the prosthesis. Prostheses present in the study were classified in Optimal (without complaint) and Problematic (complaining). Thus, the complaint related to restored arch, occlusal analysis in the function of the prosthesis, saddle quality, denture cleaning and the time when the failure is due. In conclusion, it was that the complaint \"drop alone\" was the most prominent and is related to the time of after installation failure. Poorly adapted prostheses are associated with impaired quality of life and this reinforces that the periodic returns to the prosthesis control are fundamental for clinical success of the prosthesis.
64

Avaliação da resistência à fratura de pré-molares superiores tratados endodonticamente restaurados com 'Inlays' confeccionados com dois tipos de materiais e cimentada com três cimentos resinosos / Evaluation of fracture resistance of endodontically treated maxillary premolars, restored with inlays made with two types of materials and luted with three resin cements

Vagner Leme Ortega 28 November 2000 (has links)
Este trabalho teve como objetivo comparar a resistência à fratura por compressão axial de pré-molares superiores tratados endodonticamente com preparos do tipo MOD, restaurados com “inlays” de cerâmica (IPS-Empress 2) e de cerômero (Targis), cimentadas com três cimentos resinosos de dupla polimerização (Enforce, Variolink II e Panavia F). Selecionaram-se 60 pré-molares superiores hígidos, livres de cáries e trincas, que foram extraídos por razões ortodônticas. Esses dentes foram distribuídos uniformemente, de acordo com suas dimensões vestíbulo-linguais e mésio-distais, em 6 grupos determinados pela combinação dos materiais restauradores e dos cimentos utilizados. Após a cimentação das restaurações e ciclagem térmica, os corpos de prova foram posicionados em uma máquina de ensaio universal e submetidos a uma compressão axial pelo ação de um cilindro de aço com 8mm de diâmetro, numa velocidade de 0,5mm/min, que contactava somente as vertentes triturantes das cúspides vestibular e lingual. Os melhores resultados foram obtidos, em ordem decrescente, com os cimentos Enforce (107,57kgf e 90,21kgf), Variolink II (86,44kgf e 84,07kgf) e Panavia F (82,43kgf e 76,73kgf) para as restaurações com Targis e IPS-Empress 2, respectivamente. Foram encontradas diferenças estatisticamente significantes entre os cimentos Enforce e Panavia F, independente do material restaurador utilizado. Considerando um mesmo agente cimentante, os resultados obtidos com os grupos de dentes restaurados com Targis foram ligeiramente superiores aos restaurados com IPS-Empress 2, sem apresentarem, entretanto, diferenças estatisticamente significantes entre si. / The objective of this research was to compare the fracture resistance upon axial compressive loads of maxillary premolars endodontically treated with MOD preparations restored with ceramic (IPS-Empress 2) and ceromer (Targis) inlays cemented with three dual luting cements (Enforce, Variolink II and Panavia F). Sixty premolars free of caries or fractures, extracted for orthodontic purpose were selected. They were similarly distributed according with their bucco-lingual and mesio-distal dimensions in 6 groups determined by the combination of the restoring materials and luting agents. After cementation and thermocycling procedures, the teeth were fixed in a Universal Test Machine and subjected to an axial compressive load by action of a 8mm wide steel cylinder, at the speed of 0,5mm/min., contacting only the inner aspects of the buccal and lingual cusps. The results were, in decreasing order, as follows: Enforce (107,57kgf e 90,21kgf), Variolink II (86,44kgf e 84,07kgf) and Panavia F (82,43kgf e 76,73kgf), for inlays restored with Targis and IPS-Empress 2, respectively. They were found statistically significance differences between Enforce and Panavia F, independently of the restorative material. Considering the same luting agent, the results obtained with Targis restored groups were slightly superior of those restored with IPS-Empress 2, with no statistically significance difference.
65

"Avaliação dimensional da região palatina em modelos de revestimento, após duplicação dos modelos de gesso para a confecção da estrutura metálica da prótese parcial removível, em função dos materiais duplicadores, revestimentos e da profundidade da abóbada palatina" / Dimensional evaluation of the palatal area in investment casts after the duplication of stone casts for removable partial denture framework construction in relation to the duplicating materials, investments and depth of the palatal vault.

Marcelo Alexandre Calamita 03 February 2005 (has links)
O objetivo deste estudo foi avaliar a região palatina em modelos de revestimento, após duplicação do modelo de gesso para a confecção da estrutura metálica da prótese parcial removível, em função dos materiais duplicadores, revestimentos e da profundidade da abóbada palatina. Foram utilizados 12 modelos mestres de gesso com duas diferentes profundidades da abóbada palatina, sendo seis de palato raso e seis de palato profundo. Os métodos de uplicação utilizados foram: A) Hidrocolóide reversível com revestimento aglutinado por sílica (GEL_SIL); B) Hidrocolóide reversível com revestimento aglutinado por fosfato (GEL_FOS) e C) Silicone de adição com revestimento aglutinado por fosfato (ADI_FOS). Assim, a partir de cada modelo mestre foi obtido um modelo de revestimento para cada um dos métodos descritos acima, sendo os 48 modelos resultantes aferidos com o aparelho de medição tridimensional de coordenadas e os dados analisados estatisticamente pelo método split-plot. Avaliando-se os resultados obtidos concluiu-se que: 1) Todos os métodos de duplicação produziram algum grau de imprecisão nos locais avaliados; 2) O método GEL_FOS apresentou mínimas diferenças médias em relação ao modelo mestre; 3) O método GEL_SIL apresentou diferenças médias positivas em relação ao modelo mestre, não estatisticamente significativas em relação ao método GEL_FOS; 4) O método ADI_FOS apresentou diferenças médias negativas em relação ao modelo mestre, estatisticamente significativas em relação aos métodos GEL_FOS e GEL_SIL e 5) A profundidade da abóbada palatina não influenciou significativamente os resultados obtidos. / The aim of this study was to evaluate the palatal area in investment casts after the duplication of stone casts in relation to the duplicating materials, investments and the depth of the palatal vault. Twelve master stone casts were used with two different palatal vault depths, six with a shallow palatal vault and six with a deep palatal vault. The duplicating methods used were: A) Reversible hydrocolloid with silica bonded investment (GEL_SIL); B) Reversible hydrocolloid with phosphate bonded investment (GEL_FOS), and C) Addition silicone with phosphate bonded investment (ADI_FOS). Thus, one investment cast was obtained from each master cast for each of the methods described above. The 48 resulting models were measured with a three-dimensional coordinate measurement machine, and the data were analyzed by the split-plot method. After evaluating the results we concluded that: 1) All investment casts showed some degree of distortion in the areas measured; 2) The GEL_FOS method showed the smallest average differences in relation to the master cast; 3)The GEL_SIL method showed positive, not statistically significant average differences in relation to the GEL_FOS method; 4) The ADI_FOS method showed negative, and statistically significant differences in relation to the GEL_FOS and GEL_SIL methods, and 5) The depth of the palatal vault did not influence the results significantly.
66

\"Avaliação comparativa por meio de eletromiografia de superfície do padrão de comportamento dos músculos masseter e temporal em pacientes parcialmente edentados antes e após a reabilitação com próteses parciais removíveis\" / Comparative evaluation through surface electromyograph of the temporal and masseter muscles behaviour pattern in partially edentulous patients before and after removable partial denture rehabilitation.

Jéssica Nery Navarro 15 March 2007 (has links)
Como um procedimento de avaliação, a eletromiografia clínica de superfície, envolve a detecção e o registro de potenciais elétricos de fibras musculares esqueléticas, fornecendo um instrumento útil para documentar o papel do músculo na atividade física e para avaliar a integridade do sistema neuromuscular. Tendo em vista sua utilidade, somada a relatos na literatura da existência de comprometimento muscular nos pacientes parcialmente edentados, e ainda a inexistência de relatos literários sobre a modificação do padrão de atividade muscular nos pacientes parcialmente edentados após a reabilitação; nosso objetivo nessa pesquisa foi registrar e comparar eletromiograficamente, as atividades musculares, de pacientes classe I e II de Kennedy (edentados posteriores uni ou bilaterais) em um dos arcos, antes e de 2 a 3 semanas após a instalação de próteses parciais removíveis (PPRs) e assim verificar o comportamento dos músculos masseter direito e esquerdo e temporal (feixe anterior) direito e esquerdo nessas duas situações durante a execução de abertura máxima, contração isométrica máxima voluntária (CIMV), repouso e mastigação. Após a realização desse estudo, pudemos concluir que a utilização das PPRs, restabelece os contatos oclusais posteriores perdidos e desta forma, modifica para melhor as atividades eletromiográficas da musculatura em questão (masseter e temporal). Os pacientes monitorados apresentaram um aumento extremamente significante (p < 0,0001) da eficiência da musculatura estudada durante a mastigação e ainda uma diminuição, também extremamente significante (p < 0,0001), da atividade elétrica dos masseteres e temporais durante o período de repouso e na execução da abertura máxima. / As an evaluation proceeding, the clinical surface electromyograph, envolves the detection and the registration of electric potential of muscular skinny fibers, being an useful instrument to verify the hole of the muscle in the physical activity and to evaluate the neuromuscular system condition. Keeping in mind its usefulness, added up to literature reports of the existence of muscular compromising in the partially edentulous patients, and also, the non-existence of literary articles reporting modification of muscular activity pattern in partially edentulous patients after the oral rehabilitation; our purpose in doing this research is register and compare by electromyographic study, the muscular activities, of Kennedy class I or II patients (uni or bilateral partially edentulous) in one of the arches, before and after the installation of removable partial dentures (RPDs) and also, check the behaviour of the elevator muscles: right and left masseter and right and left anterior temporal in these two situations during the execution of maximal opening, maximal isometric voluntary contraction (MIVC), rest and mastication. At the end of this study, we could conclude that the use of the RPDs, restores the oclusal contats (previously lost) and in this way, modifies the electromyographic activities of the evaluated muscles (masseter and anterior temporal). The monitored patients presented an increase extremely significant (p < 0,0001) of the musculature efficiency during the mastication and also, an extremely significant reduction (p <0,0001), of the electric activity of the four muscles during the period of rest and during the maximal opening movement.
67

Análise fotoelástica das cargas aplicadas em próteses parciais removíveis nas grandes perdas de maxila / Photoelastic analysis of the loads applied to removable partial dentures in large ressections of maxilla

Giorgia Borges de Carvalho 12 December 2012 (has links)
Este trabalho teve a finalidade de avaliar pela técnica fotoelástica, o efeito que a prótese parcial removível teria, em aliviar as tensões sobre as raízes dos dentes. Para tanto preparamos um modelo com três tipos de desenhos de próteses parciais removíveis, simulando uma reabilitação nas grandes perdas de maxila. Todos os modelos de desenhos apresentaram planos guias em incisivo central e segundo molar, e se diferenciaram da seguinte forma: modelo 01, grampo circunferencial simples em canino, grampo gêmeo entre primeiro e segundo pré-molar e grampo gêmeo entre primeiro e segundo molar; modelo 02, utilizamos os mesmos grampos colocados no modelo 01 incluindo neste modelo um recobrimento palatino, modelo 03, grampo gêmeo entre canino e primeiro pré-molar, grampo gêmeo entre segundo pré-molar e primeiro molar e grampo circunferencial simples em mesial de segundo molar. Foram aplicadas cargas verticais de 10 kg, 15 kg e 20 kg em canino, segundo pré-molar e primeiro molar. Os resultados permitiram concluir que: Os planos guia comprovaram sua efetividade através do contato pleno nos dentes preparados para o seu assentamento. O recobrimento palatino não amenizou as cargas nas raízes dos dentes. Os grampos gêmeos, colocados em uma posição mais anterior, indicam uma distribuição melhor das tensões. Os grampos circunferenciais simples, colocados mais posteriormente, indicam uma melhor distribuição das tensões. Os modelos 01 e 02 apresentaram maiores tensões em incisivo central comparados com o modelo 03. O modelo 03 foi o que melhor distribuiu as cargas de forma mais equilibrada mostrando tensões de menor magnitude. Os melhores modelos de próteses parciais removíveis, pela perspectiva de transferência de tensão foram primeiramente o modelo 03, depois o modelo 01 e por fim o modelo 02. A mudança do desenho da PPR alterou a distribuição das tensões nos dentes dos modelos avaliados. / This study aimed to evaluate by the photoelastic technique, the effect that the partial denture would have to reduce tensions on the roots of teeth. For this reason, was prepared a model with three types of removable partial dentures designs, simulating rehabilitations in large ressections of maxilla. All models presents guide-planes on central incisor and second molar, and was differentiated as follows: Model 01, simple circumferential clasp in canine, twin clasps between first and second premolar and twin clasps between first and second molar; model 02, we use the same clasps as model 01 only including a palatal covering in this model, model 03, twin clasps between canine and first premolar, twin clasps between second premolar and first molar and simple circumferential clasp at mesial of second molar. Were applied vertical loads of 10 kg, 15 kg and 20 kg in canine, second premolar and first molar. The results showed that: The guide-planes proved its effectiveness through full contact in the teeth prepared for their settlement. The palatal covering failed to alleviate the stress on the roots of teeth. Twins clasps, placed in a more anterior position, indicating a better distribution of stresses. Simple circunferencial clasp, placed in a more posterior position indicating a better distribution of stresses. Models 01 and 02 had higher tensions in central incisor compared with the model 03. The Model 03 was the best considering equilibrated load distribution showing stress of lesser magnitude. The best models of removable partial dentures, from the perspective of stress transfer were first model 03, followed by the model 01 and then finally the model 02. The change os design of RPD changed the distributions os tensions in teeth of evaluated models.
68

Avaliação in vitro da precisão de três técnicas para moldagem do arco superior parcialmente edentado / Evaluation in vitro of the accuracy of three impression techniques for the partially edentulous upper arch

Eliseu Antonio Bueno Junior 29 September 2005 (has links)
Este estudo serviu ao objetivo de avaliar a capacidade de reprodução da região do palato e o posicionamento de pilares em modelos de gesso de um arco superior parcialmente edentado, obtidos a partir de três técnicas de moldagem: 1) alginato em moldeira de estoque - AL; 2) pasta zincoeugenólica em moldeira individual, seguida de sobremoldagem com alginato em moldeira de estoque - MS e 3) silicone de condensação em moldeira de estoque pela técnica da dupla moldagem ou do reembasamento - SC. Os modelos de gesso testados foram obtidos a partir de moldagens executadas sobre modelo padrão metálico. Pontos representativos do perfil palatino, a distância relativa entre os pilares, bem como suas inclinações, foram mensurados com um aparelho de medição tridimensional de coordenadas e analisados quanto à sua fidedignidade em relação à morfologia do modelo padrão. Os resultados demonstraram que: 1) ocorreram distorções verticais positivas e negativas nos modelos produzidos pelas três técnicas, sendo que a técnica SC apresentou as maiores variações, predominantemente negativas, produzindo modelos com palato mais profundo quando comparados àqueles obtidos pelas técnicas M e A; 2) foram observadas distorções horizontais positivas e negativas nos modelos produzidos pelas três técnicas, com tendência de aumento das distâncias inter-pilares para as técnicas AL e SC e de encurtamento para a técnica MS; 3) os desvios angulares foram inexpressivos no comprometimento da inclinação axial dos pilares quando considerada a estabilização da estrutura metálica de uma prótese removível; 4) as distorções verificadas com as três técnicas estudadas estão dentro dos parâmetros de aceitabilidade clínica estabelecidos neste trabalho. / The objective of this study was to evaluate the reproduction potential of the palate area and the position of abutments in partially edentulous, upper stone casts produced with three impressions techniques: 1) irreversible hydrocolloid in stock tray - AL; 2) zinc oxide-eugenol paste in a custom tray with a pick-up impression of irreversible hydrocolloid - MS and 3) putty-wash condensation silicone in stock tray - SC. Representative points on the palatal surface and the relative distance between the abutments as well their inclination were measured with a three-dimensional coordinate measurement equipment and the data used to analyze the fidelity of the casts in relation to the original metal model. The results showed: 1) positive and negative vertical discrepancies on casts made from all impression techniques, with SC responsible for the highest variations (predominantly negatives) that rendered casts with a deeper palatal vault when compared to those obtained with AL and MS; 2) positive and negative horizontal discrepancies on casts produced from all impression techniques, with AL and SC tending to increase the distances between supports while MS seemed to decrease these distances; 3) the angular deviations observed represented no substantial compromise to the axial inclination of the abutment when considering the stability of the removable prosthesis framework; 4) the discrepancies evidenced with the three techniques were within the benchmark values for clinical acceptability initially established.
69

Estudo da resistência de quatro diferentes materiais utilizados na cimentação de pinos à infiltração lateral / Study of lateral infiltration resistance of four different materials used for posts cementing

Marcio Katsuyoshi Mukai 12 August 2010 (has links)
A raspagem e o aplainamento radicular removem o cemento presente nesta área, o qual funcionaria como barreira de dentina contra a penetração de bactérias, toxinas e outros produtos vindos da superfície externa do dente. O objetivo deste estudo foi avaliar, in vitro, em dentes tratados endodonticamente, a resistência apresentada por diferentes materiais de cimentação na infiltração do azul de metileno, que poderia atravessar a dentina radicular, quando submetido a duas diferentes situações: a) raspagem e aplainamento do cemento radicular e b) remoção de cemento com pontas diamantadas. Para isso, utilizou-se 48 dentes humanos unirradiculares, cedidos pelo banco de dentes da FOUSP, tratados endodonticamente e preparados para receberem pinos. Estes foram modelados com resina acrílica para que, por meio de fundição, fossem obtidos os retentores intrarradiculares metálicos. Os dentes foram divididos em 4 grupos com 12 espécimes, e a cada um dos grupos, destinado um tipo de material diferente para a cimentação: Cimento de Zinco® (SS White, Rio de Janeiro, Rio de Janeiro, Brasil), Cimentos resinosos Panavia F® (Kuraray, Kurashiki, Okayama, Japan), Rely X U 100® (3M Dental, Seefeld, Alemanha) e Rely X Luting 2® (3M Dental, Sant Paul, Estados Unidos). Após esse procedimento, delimitaram-se duas janelas na região cervical da raiz, sendo que num dos lados o cemento foi removido com uma ponta diamantada e no lado oposto, com 40 golpes de cureta Gracey 5-6 (Neumar, São Paulo, São Paulo, Brasil) paralelos ao longo eixo do dente. Exceto nas regiões instrumentadas, o dente foi impermeabilizado externamente e exposto à solução de azul de metileno a 1% e pH 7,2 durante 48 horas. As amostras foram desgastadas no sentido do longo eixo até o maior diâmetro do pino e a área impregnada pelo corante foi digitalizada e mensurada com o programa Imagelab®. A comparação da área impregnada pelo agente traçador na película dos cimentos, nos terços cervical e médio, revelou diferenças estatisticamente significantes entre si (p < 0,05). No lado em que a dentina foi removida com broca, houve diferença estatisticamente significante quando os três materiais adesivos foram comparados com o Cimento de Zinco (SS White, Rio de Janeiro, Rio de Janeiro, Brasil). Na comparação entre os cimentos resinosos houve diferença estatisticamente significante (p<05) somente entre os cimentos Panavia F® (Kuraray, Kurashiki, Okayama, Japan) e Rely X U 100® (3M Dental, Seefeld, Alemanha) para o terço apical. Na superfície tratada com curetas periodontais, verificou-se diferença estatisticamente significante entre os grupos estudados (p < 0,05) apenas quando comparados o cimento Rely X U 100® (3M Dental, Seefeld, Alemanha) com Rely X Luting 2® (3M Dental, Sant Paul, Estados Unidos) para o terço cervical. Concluiu-se que para o tratamento com ponta diamantada, que os cimentos Panavia F® (Kuraray, Kurashiki, Okayama, Japan), Rely X U 100® (3M Dental, Seefeld, Alemanha) e Rely X Luting 2® (3M Dental, Sant Paul, Estados Unidos) têm comportamento semelhante para os terços cervical e médio, diferindo apenas no terço apical. Já para o tratamento com curetas periodontais, os cimentos Panavia F® (Kuraray, Kurashiki, Okayama, Japan), Rely X U 100® (3M Dental, Seefeld, Alemanha) e Rely X Luting 2® (3M Dental, Sant Paul, Estados Unidos) mostraram resultados similares para os terços médio e apical, diferindo apenas no terço cervical. / Scaling and root planning remove cementum present in this area, which would acts as a dentin barrier against penetration of bacterias, toxins and other products coming from the surface of the tooth. The objective of this study was to evaluate in vitro endodontically treated teeth, the resistance of different materials to methylene blue, which could cross the root dentin when submitted to two different situations: a) scaling and root planning b) removal of cementum with drills. It was used 48 human uniradicular teeth, assigned by FOUSPs teeth bank and were endodontically treated and prepared to receive pins. These were modeled with an acrylic resin in order to obtain the metallic intraradicular posts. The teeth were divided into four groups with twelve specimens. Each one of the groups received a different material for cementing: Cement of Zinc® (SS White, Rio de Janeiro, Rio de Janeiro, Brazil), Panavia F® Resin Cements (Kuraray, Kurashiki, Okayama, Japan), Rely X U 100® (3M Dental, Seefeld, Germany) and Rely X Luting 2® (3M Dental, Sant Paul, United States). After this procedure, it was delimited two windows in the cervical region of the root. One of the sides the cementum was removed with a diamond drill and on the other side, with 40 Gracey 5-6 curette strokes (Neumar, São Paulo, Brazil) parallel to the long axis of the tooth. Except on the instrumented regions, the tooth was externally sealed and exposed to a 1% methylen blue solution and pH 7.2 during 48 hours. The samples were scraped from the long axis until the largest post diameter. The impregnated area with the dye were scanned and measured with the Imagelab® program. The comparison between the impregnated area through the tracer agent on the cement film in the cervical and medium thirds revealed statistically significant differences (p<0,05). On the side where the dentin was removed with a drill, there was a statistically significant difference when the three adhesive materials were compared to the Zinc Cement (SS White, Rio de Janeiro, Rio de Janeiro, Brazil). In the comparison between the resin cements there was a statistically significant difference (p<0,05) only between the cements: Panavia F® (Kuraray, Kurashiki, Okayama, Japan) and Rely X U 100® (3M Dental, Seefeld, Germany) for the apical third. On the surface treated with periodontal curettes, it was identified a meaningful statistical difference between the studied groups (p<0,05) only when compared the cements: Rely X U 100® (3M Dental, Seefeld, Germany) with Rely X Luting 2® (3M Dental, Sant Paul, United States) for the cervical third. The conclusion was that when the treatment uses a drill, the cements: Panavia F® (Kuraray, Kurashiki, Okayama, Japan), Rely X U 100® (3M Dental, Seefeld, Germany) and Rely X Luting 2® (3M Dental, Sant Paul, United States) have similar behavior to the cervical and medium third. The unique difference comes from the apical third. On the other hand, the treatments using periodontal curettes, the cements Panavia F® (Kuraray, Kurashiki, Okayama, Japan), Rely X U 100® (3M Dental, Seefeld, Germany) and Rely X Luting 2® (3M Dental, Sant Paul, United States) resulted in similar results for the medium and apical thirds, only differing on the cervical third.
70

"Estudo comparativo da resistência à infiltração que diferentes materiais resinosos utilizados na cimentação de retentores intra-radiculares oferecem à passagem de fluidos que atravessam a dentina" / Comparative study of the infiltration resistance that different resinous materials used in intra-radicular retainers foundation offer to the fluids passage that cross through the dentine.

Marcio Katsuyoshi Mukai 01 September 2005 (has links)
O Objetivo deste estudo é avaliar in vitro, a resistência que diferentes materiais resinosos têm a passagem de fluidos que atravessam a dentina na ausência de cemento radicular. Foram utilizados 60 dentes humanos cedidos pelo banco de dentes da FOUSP. Os dentes foram submetidos a tratamento endodôntico segundo a técnica de Paiva e Antoniazzi e armazenados a uma temperatura de 37°C em umidade 100% por 24 horas para o preparo do retentor intra -radicular respeitando o limite apical de 4 mm. Os retentores intra-radiculares foram modelados com resina tipo Duralay e fundidos com liga de prata e cimentados com os seguintes materiais: Oxifosfato de Zinco (SS White), Enforce (Dentsply), Panavia F (Kuraray) e Rely X (3M) . Após a cimentação, delimitou-se uma janela na região cervical da raiz onde o cemento foi removido com uma broca diamantada, a parte externa da raiz foi impermeabilizada com cianocrilato de etila e esmalte cosmético para posterior imersão em uma solução de azul de metileno a 1% por 48 horas. Decorrido este período, a camada impermeabilizante foi removida, os dentes foram desgastados no sentido mésio distal e avaliados com o programa Imagelab. A comparação da área impregnada pelo agente traçador na película dos cimentos, nos terços cervical e médio, revelou diferenças estatisticamente significantes (p < 0,01) do Panavia F (Kuraray) em relação aos outros três materiais, demonstrando a superioridade desse material no que se refere à impermeabilização do sistema de canais radiculares. Podemos concluir que dentre os materiais avaliados o cimento Panavia F (Kuraray) apresentou diferença estatisticamente significante, tanto para no segmento cervical quanto terço médio. / This study objective is to evaluate in vitro, the resistance that different resinous materials have through the fluids passage cross through the dentine in the absence of radicular cementum. 60 human teeth given by FOUSP bank of teeth were used. The teeth were submitted to endodontic treatment according to Paiva's and Antoniazzi´s technique and stored in a temperature of 37°C in humidity 100% during 24 hours for the preparation of the intra-radicular retainer, respecting the 4 mm apical limit. The intra -radicular retainers were modeled with Duralay resin type and melted with silver league and cemented with the following materials: Zinc Oxiphosfate (SS White), Enforce (Dentsply), Panavia F (Kuraray) and Rely X (3M). After the foundation, a window was delimited in the root cervical area where the cementum was removed with a diamond drill. The external part of the root was made waterproof with etile cyanocrylate and cosmetic enamel for subsequent immersion in a 1% blue methylen solution for 48 hours. Elapsed this period, the waterproof layer was removed, the teeth were consumed in the mesio-distal direction and appraised with the Imagelab software. The impregnated area by the tracer agent of the in the film of the cements comparison, in the cervical and medium thirds, revealed significant statistical differences (p <0,01) of Panavia F (Kuraray) in relation to the other three materials, demonstrating the superiority of that material in relationship to the radicular chanal “waterproofing” system. It’s possible to conclude that among the appraised materials, the Panavia F (Kuraray) cement presented significant statistical difference, in the cervical segment as well as the medium third.

Page generated in 0.0692 seconds