• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 10
  • 1
  • Tagged with
  • 13
  • 13
  • 6
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Cuff-less Blood Pressure Measurement Using a Smart Phone

Jonnada, Srikanth 05 1900 (has links)
Blood pressure is vital sign information that physicians often need as preliminary data for immediate intervention during emergency situations or for regular monitoring of people with cardiovascular diseases. Despite the availability of portable blood pressure meters in the market, they are not regularly carried by people, creating a need for an ultra-portable measurement platform or device that can be easily carried and used at all times. One such device is the smartphone which, according to comScore survey is used by 26.2% of the US adult population. the mass production of these phones with built-in sensors and high computation power has created numerous possibilities for application development in different domains including biomedical. Motivated by this capability and their extensive usage, this thesis focuses on developing a blood pressure measurement platform on smartphones. Specifically, I developed a blood pressure measurement system on a smart phone using the built-in camera and a customized external microphone. the system consists of first obtaining heart beats using the microphone and finger pulse with the camera, and finally calculating the blood pressure using the recorded data. I developed techniques for finding the best location for obtaining the data, making the system usable by all categories of people. the proposed system resulted in accuracies between 90-100%, when compared to traditional blood pressure meters. the second part of this thesis presents a new system for remote heart beat monitoring using the smart phone. with the proposed system, heart beats can be transferred live by patients and monitored by physicians remotely for diagnosis. the proposed blood pressure measurement and remote monitoring systems will be able to facilitate information acquisition and decision making by the 9-1-1 operators.
2

Cuff-free blood pressure estimation using signal processing techniques

Zhang, Qiao 13 September 2010
Since blood pressure is a significant parameter to examine people's physical attributes and it is useful to indicate cardiovascular diseases, the measurement/estimation of blood pressure has gained increasing attention. The continuous, cuff-less and non-invasive blood pressure estimation is required for the daily health monitoring. In recent years, studies have been focusing on the ways of blood pressure estimation based on other physiological parameters. It is widely accepted that the pulse transit time (PTT) is related to arterial stiffness, and can be used to estimate blood pressure.<p> A promising signal processing technology, Hilbert-Huang Transform (HHT), is introduced to analyze both ECG and PPG data, which are applied to calculate PTT. The relationship between blood pressure and PTT is illustrated, and the problems of calibration and re-calibration are also discussed. The proposed algorithm is tested based on the continuous data from MIMIC database. To verify the algorithm, the HHT algorithm is compared with other used processing technique (wavelet transform). The accuracy is calculated to validate the method. Furthermore, we collect data using our own developed system and test our algorithm.
3

Cuff-free blood pressure estimation using signal processing techniques

Zhang, Qiao 13 September 2010 (has links)
Since blood pressure is a significant parameter to examine people's physical attributes and it is useful to indicate cardiovascular diseases, the measurement/estimation of blood pressure has gained increasing attention. The continuous, cuff-less and non-invasive blood pressure estimation is required for the daily health monitoring. In recent years, studies have been focusing on the ways of blood pressure estimation based on other physiological parameters. It is widely accepted that the pulse transit time (PTT) is related to arterial stiffness, and can be used to estimate blood pressure.<p> A promising signal processing technology, Hilbert-Huang Transform (HHT), is introduced to analyze both ECG and PPG data, which are applied to calculate PTT. The relationship between blood pressure and PTT is illustrated, and the problems of calibration and re-calibration are also discussed. The proposed algorithm is tested based on the continuous data from MIMIC database. To verify the algorithm, the HHT algorithm is compared with other used processing technique (wavelet transform). The accuracy is calculated to validate the method. Furthermore, we collect data using our own developed system and test our algorithm.
4

Statistical Topics Applied to Pressure and Temperature Readings in the Gulf of Mexico

Allison, Malena Kathleen 01 January 2013 (has links)
The field of statistical research in weather allows for the application of old and new methods, some of which may describe relationships between certain variables better such as temperatures and pressure. The objective of this study was to apply a variety of traditional and novel statistical methods to analyze data from the National Data Buoy Center, which records among other variables barometric pressure, atmospheric temperature, water temperature and dew point temperature. The analysis included attempts to better describe and model the data as well as to make estimations for certain variables. The following statistical methods were utilized: linear regression, non-response analysis, residual analysis, descriptive statistics, parametric analysis, Kolmogorov-Smirnov test, autocorrelation, normal approximation for the binomial, and chi-squared test of independence. Of the more significant results, one was establishing the Johnson SB as the best fitting parametric distribution for a group of pressures and another was finding that there was high autocorrelation in atmospheric temperature and pressure for small lags. This topic remains conducive to future research, and such endeavors may strengthen the field of applied statistics and improve our understanding of various weather entities.
5

Time-interval based Blood Pressure Measurement Technique and System

He, Shan 19 December 2018 (has links)
Smart watches in future will have smart wristband. This work analyses properties of new developed capacitive wristband sensor that measures ballistocardiogram (BCG) from single point on the wrist. In addition, it considers applications of this sensor to monitoring heart rate variability. Another application is in estimating changes (trend) in systolic blood pressure continuously when combined with lead one electrocardiogram (ECG). BP is one of the vital signs that indicates the health condition. It is commonly measured by cuff-based monitor using either auscultatory or oscillometric method. Cuff-based BP monitor is not portable and unable to measure BP continuously which means it is difficult to attach BP monitoring function on a wearable device. Significant research is conducted in estimating BP from pulse transit time (PTT) mathematically which would enable the cuffless BP measurement. In this work, a new time reference, RJ interval, which is the time delay between ECG and BCG signal peaks was tested whether it can be used as a surrogate of PTT in cuffless BP estimation. Based on the study done on 10 healthy people, it was shown that RJ intervals can be useful in evaluating trends of systolic blood pressure.
6

Noninvasive Estimation of Pulmonary Artery Pressure Using Heart Sound Analysis

Dennis, Aaron W. 07 December 2009 (has links) (PDF)
Right-heart catheterization is the most accurate method for estimating pulmonary artery pressure (PAP). Because it is an invasive procedure it is expensive, exposes patients to the risk of infection, and is not suited for long-term monitoring situations. Medical researchers have shown that PAP influences the characteristics of heart sounds. This suggests that heart sound analysis is a potential noninvasive solution to the PAP estimation problem. This thesis describes the development of a prototype system, called PAPEr, which estimates PAP noninvasively using heart sound analysis. PAPEr uses patient data with machine learning algorithms to build models of how PAP affects heart sounds. Data from 20 patients was used to build the models and data from another 31 patients was used as a validation set. PAPEr diagnosed these 31 patients for pulmonary hypertension with an accuracy of 77 percent.
7

Pressure Estimation in the Systemic Arteries Using a Transfer Function

Thore, Carl-Johan January 2007 (has links)
<p>The aim of this thesis is to develop and study a method for estimation of the pulse pressure in centrally located arteries. Obtaining the central pulse pressure is desirable for several reasons. For example, the central pulse pressure can be used to assess aortic stiffness, which in turn is an important predictor of cardiovascular mortality. In this thesis a method of estimation based on a one--dimensional wave propagation theory applied to a physiological model of the human systemic arterial tree is studied. For the purpose of validation, recorded pressure signals from twenty four control subjects are used. Various methods for individualization of the tree model are discussed, and a method that utilizes an optimization routine is proposed.</p>
8

Pressure Estimation in the Systemic Arteries Using a Transfer Function

Thore, Carl-Johan January 2007 (has links)
The aim of this thesis is to develop and study a method for estimation of the pulse pressure in centrally located arteries. Obtaining the central pulse pressure is desirable for several reasons. For example, the central pulse pressure can be used to assess aortic stiffness, which in turn is an important predictor of cardiovascular mortality. In this thesis a method of estimation based on a one--dimensional wave propagation theory applied to a physiological model of the human systemic arterial tree is studied. For the purpose of validation, recorded pressure signals from twenty four control subjects are used. Various methods for individualization of the tree model are discussed, and a method that utilizes an optimization routine is proposed.
9

Optimizations of Optical Flow Measurement Systems

Gesemann, Sebastian 23 October 2017 (has links)
No description available.
10

Cuffless Blood Pressure Estimation Using Cardiovascular Dynamics

Samimi, Hamed 06 July 2023 (has links)
Blood pressure (BP) monitoring is an important tool for management of hypertension, which is a significant risk for cardiovascular disease and premature death. Since cuff-based BP measurement can be uncomfortable and does not provide continuous readings, several cuffless methods that are typically based on within-beat information or on the pulse transit time (PTT) have recently been investigated. This work proposes a novel cuffless BP estimation approach that mainly uses the information from cardiovascular dynamics of photoplethysmogram (PPG) waveforms. This work is divided into three parts. The first part proposes a calibration-free approach that uses dynamic changes in the pulse waveform. Results from 200 patients showed that the method achieved grade B, in terms of accuracy, for diastolic blood pressure (DBP) based on the British Hypertension Society (BHS) standard and complied with the accuracy requirements of the Association for Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) standard. The second part presents a method based on calibrated cardiovascular dynamics, achieved through a mathematical model that relates reflective PTT (R-PTT) to BP. Results from 30 patients showed a mean error (ME) of 0.58 mmHg, standard deviation of the error (SDE) of 8.13 mmHg, and a mean absolute error (MAE) of 4.93 mmHg for DBP and an ME of 2.52 mmHg, SDE of 12.28 mmHg, and an MAE of 8.82 mmHg for systolic blood pressure (SBP). The third part proposes a calibration-free method that combines morphology features and dynamic changes of the pulse waveform over short intervals. In this method a neural network was trained on 200 patients and tested on never-seen data from 25 other patients and provided an ME of -0.31 mmHg, SDE of 4.89 mmHg, and MAE of 3.32 mmHg for DBP and an ME of -4.02 mmHg, SDE of 10.40 mmHg, and MAE of 7.41 mmHg for SBP. Overall, the results show that cardiovascular dynamics may contribute useful information for cuffless estimation of BP.

Page generated in 0.1287 seconds