Spelling suggestions: "subject:"processos oxidativo alcançados."" "subject:"processos oxidative alcançados.""
71 |
Degradação de microcontaminantes emergentes e inativação de E. coli resistentes a antibióticos por processos oxidativos avançadosMiranda, Andreza Costa 13 September 2016 (has links)
Submitted by Jean Medeiros (jeanletras@uepb.edu.br) on 2017-08-04T12:08:26Z
No. of bitstreams: 1
PDF - Andreza Costa Miranda.pdf: 41222812 bytes, checksum: 456e1b5a9095a0dce0875807e9b2d2b1 (MD5) / Approved for entry into archive by Secta BC (secta.csu.bc@uepb.edu.br) on 2017-08-29T15:43:37Z (GMT) No. of bitstreams: 1
PDF - Andreza Costa Miranda.pdf: 41222812 bytes, checksum: 456e1b5a9095a0dce0875807e9b2d2b1 (MD5) / Made available in DSpace on 2017-08-29T15:43:37Z (GMT). No. of bitstreams: 1
PDF - Andreza Costa Miranda.pdf: 41222812 bytes, checksum: 456e1b5a9095a0dce0875807e9b2d2b1 (MD5)
Previous issue date: 2016-09-13 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Some micropollutants have been causing concern to health authorities with regard how they can be toxic to humans and if the conventional water treatment plants are effective for their removal. Among micropollutants currently present in the environment stand out microcystin-LR, organophosphorus pesticides (profenofos), veterinary drugs (Ivermectin) and antibiotic resistant bacteria. The low concentration of these micropollutants found in the environment requires efficient treatment and development of analytical techniques for the quantification and identification these compounds. This work was divided in two phase. In the first phase the Advanced Oxidation Processes (AOPs), namely H2O2/UV, TiO2 /UV and N-TiO2 /UV, have been compared with chlorination in the inactivation of an AR Escherichia coli (E. coli) strain in surface water.. Under the investigated conditions, chlorination (1.0 mg/L) was the faster process (2.5 min) to achieve total inactivation (6 Log). Among POA, H2O2/UV resulted in the best inactivation rate. Moreover, H2O2/UV and chlorination processes were evaluated in terms of cytotoxicity potential by means of MTT colorimetric test on a human-derived cell line and they similarly affected HepG2 cells viability. In the second phase, three fundamental aspects were evaluated: (1) degradation of micropollutants, profenofós (PFF), microcystin-LR (MC-LR) and ivermectin (IV) by H2O2/UV, H2O2 e UV; (2) validate the method for LC-MS/MS; (3) identification of oxidation by-products (OBPs) in finished water. The LC-MS/MS method for quantification of MC-LR and PFF showed good linearity with fitness coefficient (r) >0.99 and (r) >0.98, respectively. The precision, obtained was considered satisfactory. The limits of detection (LD) and quantification (LQ) were lower the Brazilian drinking water standard, suggesting the applicability of the method for the drinking water quality control .Among POA, H2O2/UV resulted in the best degradation of the micropollutants. / Alguns micropoluentes têm causado preocupações às autoridades no que diz respeito à quão tóxico podem ser a organismos humanos e os tratamentos convencionais utilizados nas estações de tratamento de água que não são eficientes em suas remoções. Dentre os micropoluentes, atualmente presentes no ambiente, destacam-se microcistina-LR, pesticidas organofosforados (profenofós), fármacos veterinários (Ivermectina) e bactérias resistentes a antibióticos. Os baixos níveis de concentração dos microcontaminantes encontrados no ambiente exigem etapas de tratamento eficientes e desenvolvimento de técnicas analíticos para quantificação e identificação segura desses compostos. Essa tese foi dividida em duas etapas. Na primeira etapa foi comparado os processos oxidativos avançados H2O2/UV, TiO2/UV e N-TiO2/UV com a cloração na inativação de cepas de Escherichia coli resistente a antibióticos presentes em água superficial. Sob estas condições, a cloração com concentração inicial de cloro em 1,0 mg/L foi o processo mais 6 eficiente a obter a inativação de uma população inicial de 10 UFC/100mL. Além disso, os processos de desinfecção com H2O2/UV e cloração foram avaliadas em termos de potencial de citotoxicidade por meio do teste colorimétrico MTT com linhagem de células derivadas dos seres humanos, os resultados mostraram que ambos os processos de desinfecção afetaram similarmente a viabilidade das células HepG2. Na segunda etapa do trabalho foram realizados estudos com três fases fundamentais: (1) Avaliar a degradação dos microcontaminantes (profenofós, microcistina-LR e ivermectina) por processo H2O2/UV, H2O2 e UV; (2) validar metodologia de técnicas analíticas para quantificação dos microcontaminantes em amostras de água por cromatografia líquida acoplada a espectrometria de massas (CLAE/MS) e; (3) Identificar os subprodutos formados com o auxílio do espectrômetro de massas com interface de ionização electrospray (ESI). A validação do método para identificação e quantificação dos microcontaminantes foi realizada por HPLC-ESI-MS/MS. Os resultados de validação calculados atenderam todas as exigências das normas consultadas e mostrou-se adequado para analisar amostras de água contendo os contaminantes estudados. Na etapa de degradação, dentre os processos utilizados, o processo H2O2/UV apresentou os melhores resultados de fotodegradação, seguido por radiação UV.
|
72 |
Águas de processo da REPLAN = qualidade e aplicação de processos oxidativos avançados / Process water from a Petroleum Refinery (REPLAN) : quality and application of advanced oxidation processGasparini, Mirthys Cozzett 18 August 2018 (has links)
Orientadores: José Roberto Guimarães, Carlos Gomes da Nave Mendes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-18T03:12:06Z (GMT). No. of bitstreams: 1
Gasparini_MirthysCozzett_M.pdf: 1574617 bytes, checksum: 879f212f74e005fca5974d6f943a790e (MD5)
Previous issue date: 2011 / Resumo: No presente trabalho foi realizada a caracterização de várias correntes de águas de processo da REPLAN (Refinaria de Paulínia), bem como a avaliação dos processos de fotólise (UV), peroxidação (H2O2), peroxidação assistida por radiação ultravioleta (H2O2/UV), reagente de Fenton (H2O2/Fe2+) e foto-Fenton (H2O2/Fe2+/UV) no tratamento de um dos efluentes, principalmente na degradação dos compostos orgânicos. Analisando-se os dados de caracterização dos diferentes efluentes foi possível sugerir alternativas de reuso no processo de refino, como também selecionar a corrente de água ácida retificada para aplicação dos processos físico-químicos de tratamento. A eficiência dos ensaios de tratabilidade foi baseada na redução da concentração do carbono orgânico dissolvido (COD). Dentre os processos estudados, os processos oxidativos avançados (POA) H2O2/UV e foto-Fenton apresentaram 95 % de eficiência após 150 minutos de ensaio. As condições ótimas foram obtidas na relação mássica COD: H2O2 de 1:7 para o processo peroxidação assistida por radiação UV, e de 1:5 e concentração de Fe2+ de 31 mg/L para o processo foto-Fenton. O efluente tratado pelo processo H2O2/UV poderia ser reutilizado como água de reposição no sistema de resfriamento, já que esta é responsável por 49 % do total de água utilizada na refinaria / Abstract: In the present study was performed the characterization of various process water from REPLAN (Paulínia Refinery) as well as an assessment of 5 processes to treat one of the effluents: photolysis (UV), peroxidation (H2O2), peroxidation assisted by ultraviolet radiation (H2O2/UV), Fenton reagent (H2O2/Fe2+) and photo-Fenton (H2O2/Fe2+/UV), in order to degrade the organic compounds. Effluents characterization results provided reuse possibilities in the process refining and also selected the stripped sour water stream for application of physical-chemical treatments. The processes efficiency was evaluated by the dissolved organic carbon (DOC) reduction. Among the processes studied, the advanced oxidation processes (AOPs) H2O2/UV and photo-Fenton reached 95 % efficiency after 150 minutes of reaction. The optimum conditions were obtained in a mass ratio COD: H2O2 of 1:7 for peroxidation assisted by UV radiation, and of 1:5 with 31 mg/L of Fe2+ for photo-Fenton. The effluent treated by AOP H2O2/UV could be reused as make-up water in cooling systems, since it is responsible for 49 % of the total water used in the refinery / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
|
73 |
Otimização da reação de fenton visando aplicações na remediação in-situ e ex-situ de aguas subterraneas / Optimization of fenton's reaction aiming at in-situ and ex-situ groundwater remediationAndrade, Juliano de Almeida 26 August 2005 (has links)
Orientador: Wilson de Figueiredo Jardim / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-05T10:39:52Z (GMT). No. of bitstreams: 1
Andrade_JulianodeAlmeida_M.pdf: 3254677 bytes, checksum: 72d1e108844df115bda11c77f7fd1337 (MD5)
Previous issue date: 2005 / Mestrado / Quimica Analitica / Mestre em Química
|
74 |
Uso de processos oxidativos avançados e ferro elementar na remediação de agua subterranea contendo compostos organoclorados / Use of advanced oxidation process and zero valent ironinremediation of groundwater containing chlorinated compoundsArruda, Tatiana Langbeck de 11 April 2005 (has links)
Orientador: Wilson de Figueiredo Jardim / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-05T13:56:31Z (GMT). No. of bitstreams: 1
Arruda_TatianaLangbeckde_M.pdf: 1545576 bytes, checksum: 2e2b76b3f7f23e5e8b1087d0e9dc7912 (MD5)
Previous issue date: 2005 / Mestrado / Quimica Analitica / Mestre em Química
|
75 |
Remoção de 17α-etinilestradiol por meio de fotocatálise em reator de leito fluidizado / Removal of 17α-ethinylestradiol by photocatalysis in bed reactor fluidizedMartins, Fernanda Lisboa 22 September 2017 (has links)
Submitted by Franciele Moreira (francielemoreyra@gmail.com) on 2017-12-04T13:25:24Z
No. of bitstreams: 2
Dissertação - Fernanda Lisboa Martins - 2017.pdf: 4877141 bytes, checksum: 9bbe680537dbf0bf672e46c97951bc77 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-12-06T11:35:00Z (GMT) No. of bitstreams: 2
Dissertação - Fernanda Lisboa Martins - 2017.pdf: 4877141 bytes, checksum: 9bbe680537dbf0bf672e46c97951bc77 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-12-06T11:35:00Z (GMT). No. of bitstreams: 2
Dissertação - Fernanda Lisboa Martins - 2017.pdf: 4877141 bytes, checksum: 9bbe680537dbf0bf672e46c97951bc77 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Previous issue date: 2017-09-22 / Fundação de Amparo à Pesquisa do Estado de Goiás - FAPEG / This work compared the efficiency of removing the 17-α-ethynylestradiol (EE2) through advanced oxidative processes (POA) and granular activated carbon adsorption (CAG). EE2 is a synthetic female hormone common in domestic sewage and effluent from pharmaceutical industries. This hormone is a type of emerging pollutant that causes endocrine disruption in living beings even in concentrations of nanograms order. The EE2 removal was analyzed in a prototype of a 10 L reactor, with upward flow CAG fluidized bed, using four lamps emitting ultraviolet radiation, with batch time of 2 hours in each process. Photolysis showed 5% of efficiency, while photocatalysis removed 87% of EE2. The adsorption processes in CAG and titanium dioxide immobilized at CAG removed 82 and 89%, respectively. / Este trabalho comparou a eficiência de remoção de 17-α-etinilestradiol (EE2) por meio de processos oxidativos avançados (POA) e adsorção em carvão ativado granular (CAG). O EE2 é um hormônio feminino sintético comum no esgoto doméstico e no efluente de indústrias farmacêuticas. Esse hormônio é um tipo de poluente emergente que causa desregulação endócrina nos seres vivos mesmo em concentrações da ordem de nanogramas. Então foi analisada a remoção do EE2 em um protótipo de reator de 10 L, com leito fluidizado de CAG, de fluxo ascendente, utilizando quatro lâmpadas que emitem radiação ultravioleta, com tempo de batelada de 2 horas, cada processo. A fotólise apresentou 5% de eficiência, enquanto a fotocatálise removeu 87% de EE2, e os processos de adsorção em CAG e em dióxido de titânio imobilizado em CAG removera, 82 e 89%, respectivamente.
|
76 |
Avaliação de processos oxidativos para o tratamento ambientalmente adequado de fluidos de corte / Evaluation of oxidative processes for the environmentally apropriate treatment of cutting fluidsElias Paulo Tessaro 17 April 2008 (has links)
Durante o processo metalúrgico de usinagem de uma peça ocorre a geração de calor proveniente do atrito ferramenta/peça e cavaco/ferramenta. Para que ocorra uma menor geração de calor possibilitando o manuseio, bem como a minimização na deformação da peça, utilizam-se fluidos, que são soluções lubrificantes à base de óleos, água ou polímeros, podendo ser sintéticos ou não, diminuindo, assim, o coeficiente de atrito reduzindo-se a quantidade de calor gerado no processo. Há uma grande variedade de fluidos de corte disponíveis no mercado que são constituídos por diversos compostos como: aminas, compostos clorados e/ou aromáticos, glicóis, nitrosaminas além da presença de metais provenientes do processo de manufatura, portanto, sem tratamento, não podem ser lançados na rede de esgoto convencional. Atualmente não há um método de tratamento para os fluidos de corte nas indústrias. Nesse contexto, propõe-se um estudo sobre a viabilidade dos tipos de tratamento dos fluidos de corte para uma disposição adequada. Os processos de tratamento propostos neste trabalho compreendem hidrolise ácida e Processo Oxidativo Avançado (POA), mais especificamente, Sistema Fenton, além de propor um tratamento baseado na fotodegradação. A caracterização do fluido antes e após seu tratamento foi realizada por técnicas analíticas e espectrométricas. Os processos oxidativos mostraram-se satisfatórios para o tratamento dos efluentes, reduzindo os níveis de contaminantes aos permitidos pela legislação. O processo foto-Fenton mostrou-se mais eficiente que o processo Fenton na degradação de todos os parâmetros avaliados, incluindo BTEX e HPAs. Os processos de hidrólise ácida não apresentaram resultados satisfatórios, reduzindo apenas os metais aos níveis permitidos para descarte. / During the cutting process, part of the heat generation results from tool-part and chip-tool friction. So that it happens a smaller generation of heat making possible the handling, as well as minimization in the tool deformation, cutting fluids are used, that are the oils base, water or polymeric lubricating solutions, could be synthetic or no, decreasing the attrition coefficient being reduced the amount of heat generated in the process. There is a great variety of cutting fluids that are constituted for several composed as: amines, chlorinated and/or aromatic composed, glycols and nitrosamines besides the presence of metals proceeding of manufacture process, therefore, without a treatment, they cannot be discarded in the conventional sewerage system. At the moment there isn\'t a treatment method for the cut fluids in the industries. In that context, intends a study about the viability types of cutting fluids treatment for appropriate disposition. Treatment processes proposed in this work understand acid hydrolysis and Advanced Oxidative Process (AOP), more specifically, Fenton System, in addition proposing a treatment based on the photodegradation (photo-Fenton process). The characterization of fluid before and after treatment it was accomplished by analytical and spectrometry techniques. Oxidative processes were exposed satisfactory for cutting fluids treatment, reducing the levels of pollutants to the allowed by the legislation. Photo-Fenton process was shown more efficient than Fenton process in the oxidation of BTEX and PAHs. Acid hydrolysis processes didn\'t present satisfactory results, just reducing the metals at the levels allowed for discard.
|
77 |
Imobilização de TiO2 P-25 em esferas de quitosana para uso em fotocatálise heterogênea / Immobilization of TiO2 P-25 in chitosan beads for use in heterogeneous photocatalysisTorres, Carolina Ferreira, 1984- 09 February 2013 (has links)
Orientador: Wilson de Figueiredo Jardim / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-24T02:49:05Z (GMT). No. of bitstreams: 1
Torres_CarolinaFerreira_M.pdf: 3163293 bytes, checksum: 169b47e5a4d52ba3e29d4ad8c88bec54 (MD5)
Previous issue date: 2013 / Resumo: O uso de fotocatalisadores suportados tem sido a estratégia preferencial em fotocatálise heterogênea, uma vez que a separação do material fotoativo do meio reacional é difícil e dispendiosa. A quitosana é um biopolímero de disponibilidade ilimitada, fonte renovável, é biodegradável e possui alto poder de adsorção. Esferas de quitosana impregnadas com TiO2 P-25 foram obtidas pela técnica de coagulação, onde uma mistura de quitosana e TiO2 P-25 é dissolvida em meio ácido e gotejada sobre um banho alcalino formando as esferas. Depois de lavadas e secas estas foram caracterizadas quanto à sua morfologia, resistência à solução ácida e à fotodegradação, área superficial, DRX, refletância de radiação UV/Vis e absorção de radiação IV. A atividade fotocatalítica das esferas foi avaliada utilizando solução de ácido salicílico 50 mg L. Placas de Petri contendo 0,5 g de esferas com relação quitosana: TiO2 P-25 na proporção de 1:10 (m/m) e 25 mL de solução de AS foram iluminadas por radiação UV e em intervalos de 8 horas alcançou-se mineralização de 40%, determinado por medidas de COT e emissão de fluorescência. As esferas foram reutilizadas em mais dois ciclos de ensaios de fotodegradação sem que passassem por qualquer processo de limpeza e sem perderem sua atividade fotocatalítica. / Abstract: The use of supported photocatalysts has been the preferred strategy for heterogeneous photocatalysis, since the separation of photoactive material from the reactional mean is difficult and expensive. Chitosan is a biopolymer of unlimited availability; it is a renewable source, biodegradable and has a high adsorption power. Chitosan beads impregnated with TiO2 P-25 were obtained by the coagulation technique, where a mixture of chitosan and TiO2 P-25 is dissolved in an acidic mean and dripped onto an alkaline bath, forming the spheres. Once washed and dried, they were characterized as to their morphology and resistance to acid solutions and photodegradation, as well as to their surface area, XRD, UV/Vis radiation reflectance and IR radiation absorption. The photocatalytic activity of the spheres was evaluated using salicylic acid solution 50 mg L. Petri dishes containing 0.5 g of beads with chitosan proportion: TiO2 P-25 at a ratio of 1:10 (w/w) and 25 mL of SA solution were illuminated by UV radiation and within 8-hour intervals a mineralization of 40% was reached, as determined by TOC measures and fluorescence emission. The beads were reused in two other test cycles of photodegradation without undergoing any cleaning process and without losing its photocatalytic activity. / Mestrado / Quimica Analitica / Mestra em Química
|
78 |
Tratamento eletrolítico de lixiviado de aterro sanitário = Electrolytic treatment of landfill leachate / Electrolytic treatment of landfill leachateSilveira, Jefferson Eduardo, 1986- 19 December 2012 (has links)
Orientador: Peterson Bueno de Moraes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Tecnologia / Made available in DSpace on 2018-08-21T23:07:04Z (GMT). No. of bitstreams: 1
Silveira_JeffersonEduardo_M.pdf: 1833335 bytes, checksum: 71226fb620b38ed3dd8fd9ee6cfac08d (MD5)
Previous issue date: 2012 / Resumo: A crescente degradação dos corpos d'água é assunto de constante interesse dos pesquisadores, da opinião pública e da mídia, devido à preocupação com a saúde pública, com os meios de produção e no legado às gerações futuras. Embora nos últimos anos as engenharias química, sanitária e ambiental tenham tido um significativo avanço nos métodos para tratamento de resíduos, alguns tipos de efluentes de composição complexa, como o lixiviado de aterro sanitário, não são adequadamente tratados pelos processos convencionais. Neste trabalho, propôs-se o uso da tecnologia eletroquímica, já utilizada na remedição de diversos tipos de resíduos e efluentes, para o desenvolvimento e aperfeiçoamento de um reator eletroquímico, em escala piloto, para tratamento do lixiviado do aterro sanitário do município de Limeira-SP. O lixiviado de aterro sanitário é um líquido escuro, com potencial patogênico, toxicológico e que pode conter compostos orgânicos como fenóis, pesticidas e íons metálicos. Foi utilizado um reator eletroquímico com eletrodos de titânio recobertos com 70%TiO2/30%RuO2 operando em batelada com recirculação, visando à redução da cor, carga orgânica e toxicidade. A partir dos resultados dos parâmetros físico-químico e biológicos, o sistema foi otimizado quanto à vazão, densidade de corrente, concentração de eletrólitos suporte e tempo de tratamento. Após 60 minutos de tratamento em densidade de corrente de 250 mA cm-2, concentração de eletrólito de 0,5 M de NaCl e vazão de 400 L h-1 foi possível remover 80% de DQO, 75% de N-NH3, 65% de COT e 90% de DBO. Levando-se em conta somente a remoção de amônia, a densidade de corrente mínima de 25 mA cm-2 já teve excelente desempenho após 30 minutos de tratamento. O sistema pode ser considerado economicamente viável para tratar este tipo de efluente em comparação aos tratamentos convencionais normalmente utilizados, com a vantagem de ser rápido, ocupar pouco espaço e não gerar lodo / Abstract: The increase in deterioration in the quality of water bodies is a subject of interest for researchers, public and media due to concern about public health. Although chemical engineering and environmental sciences have been experiencing lately significative advance in methods for wastewaters treatment, some types of effluents with complex composition such as landfill leachate are not adequately treated by conventional processes. In this work, we proposed the use of electrochemical technology, already used in the remediation of several types of waste and effluents, for development and improvement of an electrochemical pilot scale flow reactor for the treatment of raw landfill leachate from Limeira city, SP. The landfill leachate is a dark liquid with toxicological and pathogenic potential and may contain organic compounds such as phenols, pesticides and metallic ions. We used an electrochemical reactor with titanium oxide electrodes coated with 70% TiO2/30% RuO2 operating in batch recirculation mode, aiming to reduce color, organic load and toxicity. The electrochemical system was optimized from physicochemical and biological analyses considering the flow rate, current density, supporting electrolyte concentration and treatment time. Tests in 60 minutes at 250 mA cm-2, NaCl 0.5 M and flow rate of 400 L h-1 resulted on 80% COD, 75% NH3 - N, 65% TOC and 90% of BOD removal. Considering solely the removal of ammonia, 25 mA cm-2 was sufficed to reach a good performance in 30 minutes of treatment. The system showed be economically interesting for the treatment of this type of effluent when compared to conventional treatments normally used, because have the following advantages: higher degradation rates, small footprint, zero or low-generation of sludge / Mestrado / Tecnologia e Inovação / Mestre em Tecnologia
|
79 |
Tratamento de efluente farmacêutico veterinário por meio de ozonização catalítica homogênea em presença de íons Ferro / Treatment of veterinary pharmaceutical by Catalytic Homogeneous Ozonization with iron ionsPereira, Lívia Martins 13 October 2014 (has links)
A indústria farmacêutica acarreta a geração de uma quantidade significante de resíduos potencialmente poluidores. Ao serem lançados em corpos d\'água, os efluentes das indústrias farmacêuticas provocam desequilíbrio no ambiente, por transportarem compostos de difícil degradação. A ocorrência desses resíduos no ambiente pode favorecer a resistência de microrganismos frente a esses fármacos, além de causar problemas de ordem toxicológica a determinados organismos vivos. No intuito de minimizar os impactos causados pelos despejos dos efluentes desta atividade industrial, torna-se necessário estudar tratamentos alternativos para degradação de tais resíduos. Esta pesquisa teve como proposta avaliar um Processo Oxidativo Avançado: Ozonição Catalítica Homogênea em presença de íons Fe2+ como técnica para tratamento de efluente veterinário, para tanto foram estudados três diferentes reatores em sistema contínuo. Na primeira etapa do estudo, foi definido o modelo de reator mais adequado para o tratamento desse efluente farmacêutico veterinário. Na segunda etapa do estudo, utilizou-se um planejamento fatorial fracionado 24-1 para otimizar as variáveis do processo: pH, concentração de Fe2+ g/L, potência do ozonizador (vazão mássica de O3) e vazão de saída do efluente do reator. A eficiência do tratamento foi avaliada por meio da redução de Carbono Orgânico Total (COT) (%). Este estudo mostrou que a condição experimental na qual se observou a maior porcentagem de redução de COT (46,14%) ocorreu quando se combinou pH 4,0, [Fe2+] de 0,5 g/L, vazão de saída do reator de 1,23 L/h e potência do ozonizador de 56W. A avaliação estatística desse planejamento apontou para uma nova configuração experimental na qual se obteve 55,24% de redução de COT, degradação do ativo Fenbendazol de 71,24% e degradação do ativo Triclabendazol de 95,68%. Essa nova configuração combinou pH 4,0, [Fe2+] de 0,1g/L, vazão de saída do reator de 1,85 L/h e potência de 56W. / The pharmaceutical industry generates a significant amount of potentially polluting waste. When released into stream, the pharmaceutical effluents cause imbalance in the environment, transporting compounds are difficult to degrade. The occurrence of these residues in the environment can improve the microbial resistance of these drugs and cause toxicological implication of certain organisms. In order to minimize the impacts caused by discharges of effluents of this industrial activity, it is necessary to study alternative treatments for degradation of the waste. The purpose of this work was to evaluate proposed system using continuous reactors as one treatment technique Advanced Oxidative Process: Catalytic Homogeneous Ozonization with Fe2+. In the first stage of the study, the reactor model more suitable for treatment of this veterinary pharmaceutical effluent. In the second stage of the study, used a design factorial 24-1to optimize the variables of the process: pH, concentration of Fe2+ g/L, ozoniser power and output flow reactor. The efficiency of the treatment was evaluated by the reduction of Total Organic Carbon rate (TOC) (%). This study showed that the experimental condition in which it was observed the highest percentage of TOC reduction (46.14%) occurred when combined pH 4.0, [Fe 2 +] 0.5 g / L, the output flow reactor 1.23 L / h and ozoniser power of 56W. The statistical evaluation of this planning pointed to a new experimental setup in which we obtained 55.24% reduction of TOC, degradation of drug Fenbendazole 71.24% and degradation of 95.68% drug Triclabendazole. This new configuration combined pH 4.0, [Fe 2 +] of 0.1 g / L, output flow reactor of 1.85 L / h and ozoniser power of 56W.
|
80 |
Processos oxidativos com hidroperóxidos, persulfatos ou perácidos, catalisados por espécies de cobre e de ferro com potencial aplicação em química ambiental / Oxidation processes with hydroperoxides, persulphates or peracids catalyzed by copper and iron species with potential application in environmental chemistryAlmeida Filho, Saulo Afonso de 19 June 2015 (has links)
Neste trabalho, foram sintetizados complexos de cobre e ferro, com ligantes imínicos, obtidos a partir de 2-acetilpiridina e 2-(2-aminoetilpiridina) (apyepy), ou 2-acetilpiridina e 2-(aminometil)benzimidazol (apyambi), e com ligantes comerciais (ácido nitrilotriacético ou picolínico), capazes de catalisar a oxidação de poluentes, como benzeno, tolueno, etilbenzeno e xilenos (BTEX). Foi utilizado o tolueno como composto-modelo destes poluentes, que foi degradado com o uso de peróxido de hidrogênio, persulfato de sódio, ácido peracético ou peróxidos de metais alcalinos como agentes oxidantes. Os ligantes imínicos foram obtidos a partir de precursores carbonílicos e amínicos adequados, através de reações de condensação, e os correspondentes complexos metálicos de cobre(II), ferro(II) ou ferro(III) foram isolados utilizando métodos usuais de nosso laboratório. A caracterização dos compostos foi feita através de diversas técnicas analíticas e espectroscópicas: UV/Vis, infravermelho (IV) e de ressonância paramagnética eletrônica (EPR). Posteriormente, foi feita a inserção desses complexos de ferro e de cobre sintetizados em matrizes inorgânicas de niobatos e a verificação de sua reatividade em comparação com as mesmas espécies em solução. Monitorou-se a degradação do tolueno pelo peróxido de hidrogênio por cromatografia gasosa e os resultados obtidos indicaram boa atividade catalítica dos complexos, tanto em solução como inseridos em matrizes de niobato. Em solução, os complexos imínicos foram mais ativos que os de ligantes comerciais. Os compostos de ferro com ambos os ligantes imínicos mostraram-se melhores catalisadores que os correspondentes de cobre e um dos ligantes testados foi o mais eficiente (apyepy) com ambos os metais. A inserção em niobatos, aparentemente, preserva o catalisador e mantém sua atividade por mais tempo, mostrando que a inserção em niobatos beneficia o processo / In this work, iron and copper complexes were synthesized, with imine ligands obtained from 2-acetylpyridine and 2-(2-aminethylpiridine) (apyepy), or 2- acetylpyridine and 2- (aminomethyl)benzimidazole (apyambi) and commercial ligands (nitriletriacetic and picolinic acids) that are able to catalyze the oxidation of pollutant compounds as benzene, , ethylbenzene and xilenes (BTEX). Toluene was used as model compound of those pollutants, and its degradation was verified by using hydrogen peroxide, alkaline peroxide, sodium persulfate, or peracetic acid as oxidant agent. The imine ligands were obtained from adequate carbonyl and amine precursors, in condensation reactions, and the corresponding copper(II), iron(II) and iron(III) complexes were isolated by usual methods developed in our laboratory. Their characterization was carried out by analytical and spectroscopic techniques (UV/Vis, IR and EPR). Those complexes were then inserted in inorganic matrices (niobates) e its reactivity were compared to that of the analogous species in solution. Toluene degradation by hydrogen peroxide was monitored by gas chromatography, and the results showed good catalytic activity of all the complexes, both in solution and inserted into niobate matrices. In solution, the imine complexes were more efficient than the species with commercial ligands. The iron compounds with both imine ligands acted as better catalysts than the corresponding copper species, and for both metals those with the ligand apyepy were the most efficient in both cases. The insertion in niobates apparently preserves the catalyst and maintains its activity for longer, attesting that the insertion ameliorated the process.
|
Page generated in 0.1216 seconds