• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 53
  • 1
  • Tagged with
  • 54
  • 54
  • 36
  • 33
  • 16
  • 13
  • 12
  • 11
  • 11
  • 9
  • 8
  • 8
  • 8
  • 8
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

EFEITO DE CICLOS DE POLIMERIZAÇÃO EM MICRO-ONDAS SOBRE PROPRIEDADES FÍSICAS, QUÍMICA E BIOLÓGICA DE RESINAS ACRÍLICAS PARA BASE DE PRÓTESE / Effect of microwave polymerization cycles on physical, chemical and biological properties of denture base acrylic resins

Figuerôa, Rosana Marques Silva 12 February 2016 (has links)
Made available in DSpace on 2017-07-24T19:22:01Z (GMT). No. of bitstreams: 1 Rosana Marques Silva Figueroa.pdf: 3807885 bytes, checksum: 3650be97bf0d582c6f9fac01fcff5ea1 (MD5) Previous issue date: 2016-02-12 / Fundação Araucária de Apoio ao Desenvolvimento Científico e Tecnológico do Paraná / The aim of this study was to determine a microwave polymerization cycle that resulted in adequate physicomechanical and biological properties for the denture base acrylic resins polymerized in water bath (Vipi Cril-VC, VIPI®) or processed by microwave energy (Vipi Wave-VW, VIPI®). The evaluated polymerization cycles were: 1) WB (water bath) = (65ºC during 90 min + boiling during 90 min), recommended cycle for the VC resin; 2) M630/25 = 10 min at 270 W + 5 min at 0 W + 10 min at 360 W, recommended cycle for VW resin; 3) M650/5 = 5 min at 650 W; 4) M550/3 = 3 min at 550 W. The following properties were evaluated: degree of conversion (n=6), cytotoxicity (n=9), porosity (n=10), water sorption and solubility (n=10), and surface roughness and color stability (n=5) after immersion in potential colorant beverages and simulated toothbrushing. Data were submitted to analysis of variance ANOVA-2 way followed by Bonferroni’s test for degree of conversion and color stability, ANOVA-2 way for porosity and cytotoxicity, ANOVA-2 way followed by HSD Tukey’s test for water sorption and solubility, and ANOVA-3 way followed by Bonferroni’s test for surface roughness (α=0.05). For VC resin, there was no significant difference among the groups for degree of conversion. For VW resin, the lowest degree of conversion values appeared in the M630/25 and M650/5 cycles (P<0.05). Degree of conversion values ranged from 66.9 to 85.9%. There was no difference between the materials and experimental groups for cytotoxicity and all conditions resulted in non-cytotoxic effects. Porosity mean values below 1.52% with no significant difference among groups for both materials were observed. Resins showed water sorption and solubility values without a significant difference. The highest water sorption (2.43%) and solubility (0.13%) values were obtained for WB and M550/3, respectively (P<0.05). After immersion in coffee, M550/3 and WB groups of VC resin showed the highest and the lowest roughness values, respectively (P<0.05). There was also an increase in roughness of M550/3 group after immersion in wine (P<0.05). For VW resin, M650/5 group presented rougher surface after immersion in coffee (P<0.05). There was no difference in color among cycles for VW resin and VC resin showed more changes (P<0.05). All medium values were classified as acceptable, exception for VW resin (M630/25 group) which presented NBS=4.88 after immersion in wine. Vipi Cril conventional resin can be polymerized in microwave without impairment to the evaluated properties. According to the obtained results, the better experimental condition was the microwave polymerization at 650 W for 5 min for Vipi Cril. / O objetivo deste estudo foi determinar um ciclo de polimerização em micro-ondas que resultasse em propriedades físico-químicas e biológicas satisfatórias para resinas acrílicas termopolimerizáveis para base de prótese processadas em banho de água (Vipi Cril-VC, VIPI®) ou por energia de micro-ondas (Vipi Wave-VW, VIPI®). Os ciclos de polimerização avaliados foram: 1) BA (banho de água) = (65ºC por 90 min + 90 min em ebulição), ciclo recomendado para a resina VC; 2) M630/25 = 10 min a 270 W + 5 min a 0 W + 10 min a 360 W, ciclo recomendado para a resina VW; 3) M650/5 = 5 min a 650 W; 4) M550/3 = 3 min a 550 W. Foram avaliadas as seguintes propriedades: grau de conversão (n=6), citotoxicidade (n=9), porosidade (n=10), sorção de água e solubilidade (n=10) e rugosidade de superfície e estabilidade de cor (n=5) após imersão em líquidos potencialmente corantes e escovação simulada. Os resultados obtidos foram submetidos à análise de variância ANOVA-2 fatores seguida pelo teste de Bonferroni para grau de conversão e estabilidade de cor, ANOVA-2 fatores para porosidade e citotoxicidade, ANOVA-2 fatores seguida pelo teste de Tukey HSD para sorção de água e solubilidade e ANOVA-3 fatores seguida pelo teste de Bonferroni para rugosidade de superfície (α=0,05). Não houve diferença significante entre os grupos para os resultados de grau de conversão da resina VC. Para a resina VW, os valores mais baixos de grau de conversão foram obtidos nos ciclos M630/25 e M650/5 (P<0,05). Os valores médios de grau de conversão foram entre 66,9% e 85,9%. Não houve diferença entre os materiais e os grupos experimentais para os resultados de citotoxicidade e todas as condições resultaram em efeitos não citotóxicos. Foram observados valores médios de porosidade inferiores a 1,52%, sem diferença significante entre os grupos para ambos os materiais. As resinas apresentaram valores de sorção de água e solubilidade sem diferença estatisticamente significante entre elas. Os valores mais altos de sorção de água (2,43%) e de solubilidade (0,13%) foram obtidos nos grupos BA e M550/3, respectivamente (P<0,05). Com a imersão em café, os grupos M550/3 e BA da resina VC apresentaram os maiores e os menores valores de rugosidade de superfície, respectivamente (P<0,05). Também houve aumento da rugosidade do grupo M550/3 após imersão no vinho tinto (P<0,05). Para a resina VW, o grupo M650/5 demonstrou superfície mais rugosa após imersão em café (P<0,05). Não houve diferença de cor entre os ciclos para a resina VW e a resina VC apresentou mais alterações (P<0,05). Todos os valores médios de estabilidade de cor foram classificados como aceitáveis, exceto para a resina VW (grupo M630/25) que apresentou NBS=4,88 após imersão em vinho tinto. A resina Vipi Cril formulada para polimerização convencional pôde ser polimerizada em micro-ondas sem prejuízo às suas propriedades avaliadas. De acordo com os resultados obtidos, a melhor condição experimental foi a polimerização da resina Vipi Cril em micro-ondas a 650 W por 5 min.
52

A ação de sucos de frutas sobre materiais restauradores utilizados em lesões cervicais não cariosas / The action of fruit juices upon restorative materials used in noncarious cervical lesions

Cruz, Andréa Ferreira Santos da 07 November 2013 (has links)
O presente estudo in vitro analisou o efeito de 3 sucos de fruta com baixo pH (suco de cupuaçu, taperebá e laranja), e saliva artificial (controle) sobre materiais restauradores indicados em lesões cervicais não cariosas: resina composta nanoparticulada (Filtek Z350 XT), cimento de ionômero de vidro resino modificado (Vitremer) e um cimento de ionômero de vidro convencional (Fuji II). Os materiais foram avaliados, quantitativamente, quanto à alteração de: peso, rugosidade superficial e microdureza superficial, e qualitativamente, por microscopia eletrônica de varredura (MEV). Foram confeccionados 144 corpos de prova para cada teste quantitativo (n=12) e 45 para o MEV (n=3), de (8mm de diâmetro x 2mm de altura). Os corpos de prova foram preparados, mantidos em saliva artificial por 24 h à 37º C, receberam acabamento em politriz, e em seguida foram realizadas as leituras iniciais. Durante um período de 10 dias consecutivos, os corpos de prova foram submetidos ao desafio erosivo (nos respectivos sucos de frutas) durante 30 minutos três vezes ao dia, totalizando 90 minutos/dia e mantidos em saliva artificial entre os intervalos. Após o período de ciclagem erosiva, foram realizadas as leituras finais. Os resultados obtidos foram submetidos ao teste t, ANOVA e Tukey. As médias de alteração entre os valores de peso finais e iniciais demonstraram diferença significativa (p<0,01) nos materiais estudados e em todos os sucos estudados, com exceção do Vitremer quando imerso no suco de taperebá (p>0,01). As médias de alteração entre os valores de rugosidade superficial final e inicial demonstraram diferença significativa (p<0,01) para todos os materiais estudados em todos os sucos, exceto a Filtek Z350 XT no grupo controle que não apresentou diferença significativa (p>0,01). A comparação entre os valores de microdureza final e inicial demonstrou diferença significativa (p<0,01) na microdureza dos materiais estudados em todos os meios de imersão, inclusive no grupo controle. De um modo geral o suco de taperebá foi o que provocou a maior alteração na superfície dos materiais restauradores quanto ao peso, rugosidade, microdureza e na microscopia eletrônica de varredura. A resina composta Filtek Z350 XT foi o material restaurador que menos sofreu alterações de superfície. Concluiu-se que os sucos das frutas estudados são capazes de alterar os materiais restauradores, sendo que a resina composta foi o material que sofreu menor alteração. / This in vitro study examined the effects of 3 fruit juices with low pH (cupuaçu, taperebá and orange) and artificial saliva (control) upon restorative materials indicated in noncarious cervical lesions: nanoparticle composite resin (Filtek Z350 XT), resin-modified glass ionomer cement (Vitremer) and a glass ionomer cement (Fuji II). The materials were evaluated quantitatively as for alterations in weight, surface roughness and surface microhardness, and qualitatively by scanning electronic microscopy (SEM). 144 specimens were prepared for each quantitative test (n = 12) and 45 for the SEM (n = 3), of (8mm diameter x 2mm height). The specimens were prepared, stored in artificial saliva for 24 hours at 37º C, were finished in a polishing machine, and then the initial readings were performed. During a period of 10 consecutive days, the specimens were subjected to erosive challenge (in the respective juices) for 30 minutes, three times a day, and totaling 90 minutes/day and kept in artificial saliva between intervals. After the erosive cycling period, the final readings were taken. The data were analyzed using t test, ANOVA and Tukey.Test The average alterations between the values of initial and final weight showed significant difference (p < 0.01) in the material studied and all the juices studied, except for Vitremer when immersed in taperebá juice (p > 0.01). The average alterations between the values of initial and final surface roughness showed a significant difference (p < 0.01) for all materials studied in all juices, except for Filtek Z350 XT, in the control group, that showed no significant differences (p > 0.01). The comparison between the values of initial and final microhardness showed a significant difference (p < 0.01) in microhardness of the materials studied in all immersion means, including the control group. In general, taperebá juice was the one that caused the biggest alterations in the surface of restorative materials with respect to weight, roughness, hardness and scanning electronic microscopy. The composite resin Filtek Z350 XT was the restorative material that suffered less surface alterations. It was concluded that the fruit juices studied are capable of altering the restorative materials, and composite resin was the material that has undergone minor changes.
53

Influência do método de aquecimento de revestimentos fosfatados sobre sua resistência à compressão e sobre a rugosidade de superfície e estabilidade dimensional de ligas de Ni-Cr e Ni-Cr-Ti

Zequetto, Michele Marques [UNESP] 24 March 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-03-24Bitstream added on 2014-06-13T20:06:15Z : No. of bitstreams: 1 zequetto_mm_dr_araca.pdf: 383469 bytes, checksum: 3fd20e10aa2c413edb650399efcff201 (MD5) / No processo de fundição pela cera perdida, os materiais envolvidos podem apresentar interações entre si e o de tempo despendido para se obter as estruturas metálicas é oneroso. Assim, o objetivo deste trabalho foi avaliar a influência da propriedade física de resistência à compressão de revestimentos fosfatados indicados para altas temperaturas de fundição, utilizando os métodos de aquecimento convencional (MAC) e rápido (MAR), e analisar a rugosidade de superfície e a alteração dimensional do produto final da fundição (a peça metálica) obtido com as ligas metálicas Ni-Cr (Verabond II) e Ni-Cr-Ti (Fit Cast Titanium). Os revestimentos estudados Castorit Super C, Castorit All Speed, Heat Shock e Micro Fine 1700 foram vazados em uma matriz de silicone que permitiu obter amostras com formato cilíndrico (n=200), medindo 10mm de diâmetro e 20mm de comprimento. A resistência (MPa) deles foi determinada à temperatura ambiente (resistência fria) após 15, 30 e 60 minutos de manipulação, e também imediatamente após serem submetidos aos métodos de aquecimento MAC e MAR (resistência de queima), por meio de uma máquina de ensaio universal, em velocidade de 0,05mm/min e carga de 150kgf. Após inclusão, aplicação dos métodos de aquecimento e fundição às amostras (n=120) para rugosidade de superfície (Ra-μm), foram avaliadas por um rugosímetro Mitutoyo Surftest SJ-401 com cut-off de 0,8mm e três repetições em cada amostra. A alteração dimensional foi determinada pela diferença entre os valores dimensionais da cera e da peça fundida (n=60) utilizando-se o software AutoCad2008. Os valores médios obtidos foram submetidos à análise de variância (ANOVA) e ao teste de Tukey (p<0,05), apresentando os valores de resistência à compressão diferentes entre os revestimentos (Heat Shock os valores maiores) e entre os tempos de mensuração em relação... / In the lost wax casting procedure, the involved materials can present interactions among them and the time used to obtain the metallic structures is onerous. Thus, the purpose of this study was to evaluate the influence of the compressive strength physical property of phosphate-bonded investment materials indicated for high casting temperatures, utilizing conventional heating (CHM) and quick heating methods (QHM), and analyze the surface roughness and the dimensional accuracy of the final casting product (the metallic piece) obtained from Ni-Cr (Verabond II) and Ni-Cr-Ti (Fit Cast Titanium) metallic alloys. Castorit Super C, Castorit All Speed, Heat Shock and Micro Fine 1700 investment materials were poured into a silicone matrix in order to obtain cylindrical samples (n=200), measuring 10mm in diameter and 20mm in length. Their strength (MPa) was determined at room temperature (green strength) after 15, 30 and 60 minutes of manipulation, and also immediately after being submitted to the CHM and QHM heating methods (fired strength), by means of an universal testing machine at 0,05mm/min speed and 150kgf load. After investing, applying the heating methods and casting the samples (n=120) for surface roughness (Ra), the samples were evaluated with a Mitutoyo Surftest SJ-400 profilometer with 0,8mm cut-off, three times in each sample. The dimensional accuracy was determined by the difference among the dimensional values of the wax and of the metallic piece (n=60) through the software AutoCad2008. The mean values obtained were submitted to ANOVA and Tukey tests (p <0.05), and the results showed that the values of compressive strength were different among the investment materials (Heat Shock presenting the highest values) and among the analysis times with a direct relation of time and strength increase, but there was no difference between CHM and QHM. Moreover, it was observed no differences... (Complete abstract click electronic access below)
54

A ação de sucos de frutas sobre materiais restauradores utilizados em lesões cervicais não cariosas / The action of fruit juices upon restorative materials used in noncarious cervical lesions

Andréa Ferreira Santos da Cruz 07 November 2013 (has links)
O presente estudo in vitro analisou o efeito de 3 sucos de fruta com baixo pH (suco de cupuaçu, taperebá e laranja), e saliva artificial (controle) sobre materiais restauradores indicados em lesões cervicais não cariosas: resina composta nanoparticulada (Filtek Z350 XT), cimento de ionômero de vidro resino modificado (Vitremer) e um cimento de ionômero de vidro convencional (Fuji II). Os materiais foram avaliados, quantitativamente, quanto à alteração de: peso, rugosidade superficial e microdureza superficial, e qualitativamente, por microscopia eletrônica de varredura (MEV). Foram confeccionados 144 corpos de prova para cada teste quantitativo (n=12) e 45 para o MEV (n=3), de (8mm de diâmetro x 2mm de altura). Os corpos de prova foram preparados, mantidos em saliva artificial por 24 h à 37º C, receberam acabamento em politriz, e em seguida foram realizadas as leituras iniciais. Durante um período de 10 dias consecutivos, os corpos de prova foram submetidos ao desafio erosivo (nos respectivos sucos de frutas) durante 30 minutos três vezes ao dia, totalizando 90 minutos/dia e mantidos em saliva artificial entre os intervalos. Após o período de ciclagem erosiva, foram realizadas as leituras finais. Os resultados obtidos foram submetidos ao teste t, ANOVA e Tukey. As médias de alteração entre os valores de peso finais e iniciais demonstraram diferença significativa (p<0,01) nos materiais estudados e em todos os sucos estudados, com exceção do Vitremer quando imerso no suco de taperebá (p>0,01). As médias de alteração entre os valores de rugosidade superficial final e inicial demonstraram diferença significativa (p<0,01) para todos os materiais estudados em todos os sucos, exceto a Filtek Z350 XT no grupo controle que não apresentou diferença significativa (p>0,01). A comparação entre os valores de microdureza final e inicial demonstrou diferença significativa (p<0,01) na microdureza dos materiais estudados em todos os meios de imersão, inclusive no grupo controle. De um modo geral o suco de taperebá foi o que provocou a maior alteração na superfície dos materiais restauradores quanto ao peso, rugosidade, microdureza e na microscopia eletrônica de varredura. A resina composta Filtek Z350 XT foi o material restaurador que menos sofreu alterações de superfície. Concluiu-se que os sucos das frutas estudados são capazes de alterar os materiais restauradores, sendo que a resina composta foi o material que sofreu menor alteração. / This in vitro study examined the effects of 3 fruit juices with low pH (cupuaçu, taperebá and orange) and artificial saliva (control) upon restorative materials indicated in noncarious cervical lesions: nanoparticle composite resin (Filtek Z350 XT), resin-modified glass ionomer cement (Vitremer) and a glass ionomer cement (Fuji II). The materials were evaluated quantitatively as for alterations in weight, surface roughness and surface microhardness, and qualitatively by scanning electronic microscopy (SEM). 144 specimens were prepared for each quantitative test (n = 12) and 45 for the SEM (n = 3), of (8mm diameter x 2mm height). The specimens were prepared, stored in artificial saliva for 24 hours at 37º C, were finished in a polishing machine, and then the initial readings were performed. During a period of 10 consecutive days, the specimens were subjected to erosive challenge (in the respective juices) for 30 minutes, three times a day, and totaling 90 minutes/day and kept in artificial saliva between intervals. After the erosive cycling period, the final readings were taken. The data were analyzed using t test, ANOVA and Tukey.Test The average alterations between the values of initial and final weight showed significant difference (p < 0.01) in the material studied and all the juices studied, except for Vitremer when immersed in taperebá juice (p > 0.01). The average alterations between the values of initial and final surface roughness showed a significant difference (p < 0.01) for all materials studied in all juices, except for Filtek Z350 XT, in the control group, that showed no significant differences (p > 0.01). The comparison between the values of initial and final microhardness showed a significant difference (p < 0.01) in microhardness of the materials studied in all immersion means, including the control group. In general, taperebá juice was the one that caused the biggest alterations in the surface of restorative materials with respect to weight, roughness, hardness and scanning electronic microscopy. The composite resin Filtek Z350 XT was the restorative material that suffered less surface alterations. It was concluded that the fruit juices studied are capable of altering the restorative materials, and composite resin was the material that has undergone minor changes.

Page generated in 0.0695 seconds