• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 534
  • 269
  • 39
  • 39
  • 23
  • 17
  • 17
  • 17
  • 17
  • 16
  • 11
  • 10
  • 7
  • 4
  • 4
  • Tagged with
  • 1027
  • 457
  • 319
  • 246
  • 131
  • 126
  • 125
  • 115
  • 95
  • 88
  • 84
  • 81
  • 75
  • 73
  • 69
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
151

Synthetic vascular graft infection an experimental study with special reference to host mechanisms affecting bacterial graft colonization /

Zdanowski, Zbigniew. January 1993 (has links)
Thesis (doctoral)--Lund University, 1993. / Added t.p. with thesis statement inserted.
152

Toward Better Representations of Sound with Cochlear Implants

Wilson, Blake Shaw January 2015 (has links)
<p>This dissertation is about the first substantial restoration of human sense using a medical intervention. In particular, the development of the modern cochlear implant (CI) is described, with a focus on sound processors for CIs. As of October 2015, more than 460 thousand persons had each received a single CI on one side or bilateral CIs for both sides. More than 75 percent of users of the present-day devices use the telephone routinely, including conversations with previously unknown persons and with varying and unpredictable topics. That ability is a long trip indeed from severe or worse losses in hearing. The sound processors, in conjunction with multiple sites of highly-controlled electrical stimulation in the cochlea, made the trip possible.</p><p>Many methods and techniques were used in the described research, including but not limited to those of signal processing, electrical engineering, neuroscience, speech science, and hearing science. In addition, the results were the products of collaborative efforts, beginning in the late 1970s. For example, our teams at the Duke University Medical Center and the Research Triangle Institute worked closely with investigators at 27 other universities worldwide. </p><p>The most important outcome from the research was unprecedented levels of speech reception for users of CIs, which moved a previously experimental treatment into the mainstream of clinical practice.</p> / Dissertation
153

Efeito da desinfecção química e do envelhecimento acelerado sobre a estabilidade dimensional, reprodução e manutenção de detalhes e estabilidade de cor do silicone facial Silastic MDX 4-4210 com opacificador

Haddad, Marcela Filié [UNESP] 03 March 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-03-03Bitstream added on 2014-06-13T20:37:55Z : No. of bitstreams: 1 haddad_mf_me_araca.pdf: 2948188 bytes, checksum: 2fbab93d0b5d242f0543ea496a3c8a05 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este estudo teve como objetivo avaliar a estabilidade dimensional, reprodução de detalhes e estabilidade de cor de silicone facial, com adição ou não de pigmento e opacificador; sob influência da desinfecção química e do envelhecimento acelerado. Para isso, foram obtidas 120 amostras, utilizando o silicone Silastic MDX 4-4210, divididas em 4 grupos contendo 30 amostras cada, sendo GI - incolor, GII - pigmentado com pó de cerâmica, GIII – com adição de sulfato de bário (opacificador) e GIV- pigmentado com pó de cerâmica e sulfato de bário. Dez amostras de cada grupo foram desinfetadas com uma das três substâncias a seguir: pastilhas efervescentes a base de peróxido alcalino, sabão neutro ou clorexidina. O processo de desinfecção química foi realizado três vezes por semana, durante 60 dias. Após esse período, todas as amostras foram submetidas ao envelhecimento acelerado. Os testes de estabilidade dimensional, reprodução de detalhes e estabilidade de cor foram realizados no período inicial, após 60 dias de desinfecção e, nos intervalos de 252, 504 e 1008 horas de envelhecimento acelerado. As amostras foram analisadas em computador pelo sistema AutoCAD para verificação da alteração dimensional linear; e observadas em lupa estereoscópica para a análise da reprodução de detalhes. A estabilidade de cor foi verificada por meio de espectrofotometria de reflexão. Os valores obtidos nos testes de estabilidade dimensional e estabilidade cromática foram submetidos à análise de variância e teste de Tukey (p<0,05). Para a análise da reprodução e manutenção de detalhes foi utilizado escore de 0 a 2. O fator desinfecção não influenciou estatisticamente nos valores de estabilidade dimensional, reprodução de detalhes e estabilidade de cor do silicone, independente da... / The aim of this study was to evaluate the dimensional stability, reproduction and maintenance of details and color stability of facial silicone, with different pigmentation, on the influence of the disinfection and accelerated aging. 120 samples were obtained, using Silastic MDX 4-4210 elastomer, divided in 4 groups with 30 samples: GI - colorless, GII - pigmented with ceramics, GIII - pigmented with barium sulfate opacifier, and GIV - pigmented with ceramics and barium sulfate opacifier. Ten samples of each group was submitted to the disinfection with effervescent tablets, with neutral soap or 4% chlorhexidine, three times a week during 60 days. After this period all samples were taken to a chamber of accelerated aging for not metallic bodies. The tests of dimensional stability, maintenance of the details, and color stability were realized after the confection, disinfection and in the intervals of each cycle of accelerated aging (252, 504 e 1008 hours). Samples were analyzed, in computer by the AutoCAD system to verification of the linear dimensional alteration and observed, in stereoscopic magnifying glass for analysis of the reproduction of details. The color stability was analyzed by means of spectrophotometer. The dimensional alteration and color stability values had been submitted to the analysis of variance and Tukey test (p<0.05). For the analysis of detail reproduction, the 0 -2 scores were used It can be observed that the factor: chemical disinfection had no influenced statistically on dimensional stability, detail reproduction and color stability values. Accelerated aging had influenced statistically on dimensional stability values after 1008 hours. About detail reproduction, all samples exhibited score 2 for all analyzed periods. Pigment and opacifier association was more stable for chromatic stability test in all analyzed... (Complete abstract, click electronic address below)
154

Influência do intemperismo natural ou induzido sobre a estabilidade cromática de próteses faciais, em função do material de confecção e da pigmentação

Santos, Daniela Micheline dos [UNESP] 21 January 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-01-21Bitstream added on 2014-06-13T19:58:22Z : No. of bitstreams: 1 santos_dm_me_araca.pdf: 1205156 bytes, checksum: fffe6214d9a798b0c0b924994c235e30 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O maior problema enfrentado pelo protesista bucomaxilofacial é reproduzir a cor exata da pele do paciente, proporcionando uma estética agradável. Para alcançar este objetivo, o profissional deve ter materiais que possibilitem uma fácil caracterização, mantendo por um longo período de tempo a cor obtida. O propósito do presente estudo foi avaliar a estabilidade de cor de resinas acrílicas (Rapidaflex, Lentaflex e Resina Acrílica Termopolimerizável incolor e pigmentada) e de um silicone (Silastic MDX4-4210 incolor e com pigmentação) utilizados na confecção de próteses faciais, submetidos ao intemperismo natural ou artificial. Foram confeccionados 120 corpos-de-prova distribuídos em doze grupos. Metade dos corpos-de-prova foram submetidos ao envelhecimento natural por 180 dias, e a outra metade ao envelhecimento acelerado por 1008 horas. A alteração cromática dos corpos-de-prova foi verificada por meio da análise visual e da espectrofotometria de reflexão (Shimadzu, Kyoto, Japão). Os resultados foram submetidos à análise estatística pelos testes de Variância (ANOVA) de dois fatores e Tukey, com significância de 5%. Pode-se observar pela análise espectrofotométrica e visual que, independente do tipo de envelhecimento, ocorreu alteração de cor, estatisticamente significativa, entre alguns materiais. Os corpos-de-prova submetidos ao envelhecimento natural apresentaram maiores valores de alteração de cor do que aqueles submetidos ao envelhecimento acelerado. Todos os materiais sofreram alteração cromática pela influência da exposição ao meio ambiente ou pela ação do envelhecimento acelerado. / The great problem that confronts the maxillofacial prosthodontist is reproduces the accurate color of the patient’s skin, providing a satisfactory esthetic. Attempt to reach this purpose; the clinician should have materials to make an easy characterization, keeping the color by the time. The aim of this study was to evaluate the color stability of acrylic resins (Rapidaflex, Lentaflex and heat-cured colorless and pigmented acrylic resins) and a silicone (colorless and pigmented Silastic MDX4-4210) used to the confection of facial prostheses, submitted to natural or artificial weathering. 120 samples were made and distributed in twelve groups. 60 samples were submitted to the natural aging by 180 days, and the other half were submitted to the accelerated aging by 1008 hours. The chromatic differences were verified by means of the visual analysis and reflection spectrophotometer (Shimadzu, Kyoto, Japan). The results were analyzed by two-way analysis of variance (ANOVA) and Tukey tests (P<0,05). Color changes, between some materials, were observed by spectrophotometer and visual analysis, independently of the type of aging; it was statistically significant. The samples submitted to the natural aging showed higher values than the samples submitted to the accelerated aging. All materials suffered chromatic differences because to the environment exposure or the accelerated aging.
155

Avaliação da estabilidade cromática da pintura de íris em próteses oculares polimerizadas por energia de microondas, variando a cor, a tinta e o método de secagem

Fernandes, Aline Úrsula Rocha [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2004Bitstream added on 2014-06-13T19:16:54Z : No. of bitstreams: 1 fernandes_aur_me_araca.pdf: 952229 bytes, checksum: 8e65200d34f1586880d463d53baa7659 (MD5) / Universidade Estadual Paulista (UNESP) / A íris artificial é a estrutura da prótese ocular responsável pela sua dissimulação e estética. O propósito do presente trabalho foi avaliar a alteração de cor de tintas utilizadas na pintura de íris em próteses oculares polimerizadas por energia de microondas, variando-se tinta, cor e método de secagem. Para o estudo, foram confeccionados cinco discos em resina termopolimerizável por microondas para cada tinta analisada: acrílica hidrossolúvel, automotiva à base de nitrocelulose, guache hidrossolúvel e a óleo, nas cores marrom e azul, para os métodos de secagem natural e por radiação infravermelha, perfazendo um total de 80 corpos-de-prova. Cada corpo-de-prova foi constituído por um disco de resina acrílica incolor e outro, de igual dimensão, de resina acrílica de coloração branca de esclera e, entre os dois discos, a pintura. Os corposde- prova foram submetidos a uma câmara de envelhecimento acelerado sob radiação ultravioleta, por 1008 horas. Para avaliar as variações de cor foi usado um espectrofotômetro de reflexão. Os resultados foram analisados estatisticamente por Análise de Variância e teste de Tukey a 5% de significância. Todas as tintas sofreram alteração cromática. A tinta a óleo apresentou a maior resistência frente ao envelhecimento acelerado, independente da cor e do método de secagem. / The artificial iris is the structure of the ocular prosthesis responsible for its dissimulation and aesthetics. The objective of the present study was to evaluate the color stability of paint used for iris painting for ocular prosthesis polymerized with microwaves, varying painting, color and drying method. For the study, 80 discs in heat-curing for microwaves acrylic resin were made, five discs for each paint analyzed: acrylic water-soluble paints, automotive nitrocellulose paints, watercolor paints and oil paints, for the colors brown and blue, for both natural and infrared drying methods. Each specimen was constituted of one disc in colorless acrylic resin and another colored with a basic sclera pigment. The painting was accomplished in one of the surfaces of one of the discs. The specimens were submitted to an artificial aging chamber under ultraviolet light, during 1008 hours. To evaluate color changes a reflective spectrophotometer was used. The data were statistically analyzed by Variance Analysis and Tukey’s test. All paints suffered color alteration. The oil paints presented the highest resistance to artificial aging regardless the pigment and the drying method.
156

Avaliação da estabilidade de cor após o envelhecimento acelerado de dois silicones pigmentados ou não para uso em próteses faciais

Mancuso, Daniela Nardi [UNESP] 03 October 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-10-03Bitstream added on 2014-06-13T20:37:56Z : No. of bitstreams: 1 mancuso_dn_me_araca.pdf: 2113835 bytes, checksum: 27a105a29a2894608038cc448f18dd65 (MD5) / Universidade Estadual Paulista (UNESP) / O objetivo desta pesquisa foi o de avaliar a estabilidade de cor dos silicones faciais pigmentados e não pigmentados após o envelhecimento acelerado. Foram utilizados dois silicones, sendo um de fabricação estrangeira, próprio para próteses faciais, e um silicone acético de fabricação nacional, de uso industrial. Foram confeccionados 24 corpos-de-prova para cada silicone, divididos em grupos incolor e pigmentados intrinsecamente com: cerâmica; maquiagem; óxido de ferro. Os grupos foram submetidos ao sistema acelerado de envelhecimento para não-metálicos - ultravioleta B / condensação (Comexim, Brasil). Foi feita leitura inicial e após períodos correspondentes a 163, 351, 692 e 1000 horas de envelhecimento, através do método visual de comparação e da análise por espectrofotômetro de reflexão Color-Eye (MacBeth, USA), utilizando o Sistema CIE L*a*b*. Os valores foram submetidos à análise de variância e teste de Tukey em nível de 5% de probabilidade. Todos os grupos apresentaram estabilidade de cor no método visual de comparação. Mas, com relação à espectrofotometria de reflexão, após as 1000 horas de envelhecimento acelerado, tanto o 732 RTV, quanto o MDX, pigmentados com maquiagem, apresentaram alteração de cor. Para o grupo incolor, em 351 horas de envelhecimento, tanto o 732 RTV, quanto o MDX, apresentaram alteração. Conclui-se então que os dois silicones possuem boa estabilidade de cor em todos os grupos estudados, com exceção da maquiagem que foi considerada a mais instável dentre os pigmentos para os dois silicones. / The objective of this research was evaluating the color stability of the facial silicones pigmented and without pigmentation after the accelerated aging. A foreign silicone created specifically for facial prostheses and a national acetic silicon for industrial use were used in research. 20 bodies-of-proof were made for each silicone, divided in colorless and intrinsically pigmented groups with: ceramic; make-up; oxide of iron. The groups were submitted to the accelerated System of aging for no-metallic - Ultraviolet B / condensation (Comexim, Brazil). An initial evaluation and evaluations after 163, 351, 692 and 1000 hours of aging were made. The visual method of comparison and the analysis for reflection spectrophotometer Color-Eye (MacBeth, USES) were used with the CIE L*a*b * System. The values were submitted to the variance analysis and Tukeyþs test in level of 5% of probability. All groups presented color stability in visual method. After 1000 hours of accelerated aging, Silastic 732 RTV and MDX, both pigmented with make-up presented color change in spectrophotometer analysis. The Silastic 732 RTV and MDX colorless groups presented color change in 351 hours of aging. It was concluded that all groups of both silicones had good color stability, except make-up group that was considered the most unstable pigment for both silicones.
157

Influência do torque e da ciclagem mecânica na manutenção da pré-carga e resistência à fratura de parafusos de retenção em diferentes junções parafusadas / Influence of torque and mechanical cycling in preload maintenance and resistance to fracture of retaining screws in different implant-joints

Silva, Ebele Adaobi [UNESP] 17 June 2016 (has links)
Submitted by Ebele Adaobi Silva (silva.ebele@gmail.com) on 2016-08-11T15:23:23Z No. of bitstreams: 1 Dissertação_EbeleAdaobiSilva_Prótese.pdf: 1233295 bytes, checksum: 6ef711a36dbbc6aaf483494459874418 (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-08-11T18:16:49Z (GMT) No. of bitstreams: 1 silva_ea_me_araca.pdf: 1233295 bytes, checksum: 6ef711a36dbbc6aaf483494459874418 (MD5) / Made available in DSpace on 2016-08-11T18:16:49Z (GMT). No. of bitstreams: 1 silva_ea_me_araca.pdf: 1233295 bytes, checksum: 6ef711a36dbbc6aaf483494459874418 (MD5) Previous issue date: 2016-06-17 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Sendo o afrouxamento e fratura dos parafusos de retenção as principais complicações em próteses implantossuportadas, este estudo teve como objetivo avaliar a manutenção do torque remanescente e ocorrência de fraturas em parafusos de retenção de pilares UCLA, para implantes de conexão hexagonal externa e cone Morse, em função do torque aplicado (recomendado pelo fabricante, torque obtido através de aperto manual e sem torque), submetidos à ciclagem mecânica. Sequencialmente, investigou-se a resistência à fratura desses parafusos por meio do teste de compressão em uma máquina de ensaio universal. Foram utilizados 36 implantes embutidos em poliuretano com uma inclinação de 30°, divididos em 6 grupos em função do tipo de conexão e do torque aplicado. De forma randomizada, os espécimes pertencentes ao grupo sem torque foram submetidos a ciclagem mecânica e os dos grupos torque recomendado pelo fabricante e torque manual foram submetidos a aplicação do torque e mensuração da pré-carga remanescente, antes (3 minutos após o aperto) e após a ciclagem mecânica (após 1x106 de ciclos). Ao fim da ciclagem, os parafusos foram submetidos ao teste de resistência a fratura por meio do ensaio de compressão, no qual foi aplicado uma carga de 5000N sob a velocidade de 0,5mm/min. Os resultados mostraram que em uma análise geral, o torque remanesce foi significantemente menor (p<0,05) após a ciclagem mecânica. Ao se comparar os dois tipos de conexão, não houve diferença em relação o torque remanescente (p>0,05). Para os diferentes tipos de torque, observou-se que quando se aplicou o torque recomendado pelo fabricante o torque remanescente foi significativamente maior (p<0,05) quando comparada ao grupo que recebeu o torque manual. Dos 36 parafusos de retenção dos pilares UCLA submetidos à ciclagem mecânica, 3 fraturaram, equivalendo a 8,33%. Submeteu-se ao teste de resistência a compressão 33 parafusos de retenção ciclados e 12 novos, sendo 6 para a conexão CM e 6 para a HE. Os parafusos novos apresentaram as maiores médias para a força máxima (116,80 Kgf) e também para deformação na força máxima (2,18 mm), havendo diferença estatisticamente significativa (p<0,05) ao se comparar com os parafusos ciclados. Comparando-se os tipos de conexão, os parafusos dos grupos de conexão Hexágono externo apresentaram a maior média de força máxima (FM). Dos 12 parafusos novos, 6 fraturaram durante o teste, sendo 3 de cada tipo de conexão. Já para os parafusos ciclados, houve a mesma quantidade de fratura, sendo 3 para a conexão cone Morse e 3 para a Hexágono externo. A maior média para força de ruptura (FR) ocorreu também nos parafusos novos. Conclui-se então que a ciclagem mecânica e os diferentes valores de torque de inserção, sendo estes abaixo do que se recomenda o fabricante, interferiram negativamente nos valores de torque remanescente dos parafusos de retenção das junções parafusadas nas condições avaliadas e embora os parafusos submetidos a ciclagem tenham apresentado uma menor média de força de ruptura, a diferença encontrada não apresentou poder estatístico que comprovasse sua influência na fratura dos parafusos de retenção testados. / Being loosening and fracture of retention screws the main complications in implant-supported prostheses, this study aimed to evaluate the preload maintenance and the occurrence of fractures at retention screws of UCLA-type abutment for implants with external hexagon connection and Morse Taper, due to the applied torque (recommended by the manufacturer, torque obtained by manual tightening and no torque), submitted to mechanical cycling. Sequentially, the fracture resistance of these screws was investigated by the compression test on a universal testing machine. Thirty-six implants embedded in polyurethane with an inclination of 30° were used and divided into 6 groups according to the type of connection and the applied torque. Randomly, the specimens belonging to the group without torque underwent mechanical cycling and groups of recommended by the manufacturer torque and manual torque underwent torque application and measurement of the remaining preload, before (three minutes after tightening) and after mechanical cycling (after 1x106 cycles). After cycling, the screws were submitted to the fracture resistance test by the compression test, which was applied a 5000N load under 0,5 mm/min speed. The results showed that in a general analysis, preload maintenance was significantly lower (p <0,05) after mechanical cycling. When comparing the two types of connection, there was no difference regarding to preload maintenance (p>0,05). For different types of torque, it was observed that, when it was applied the recommended by the manufacturer torque, the preload maintenance was significantly higher (p <0,05) compared to the group that received the manual torque. Of the 36 retention screws of UCLA-type abutments submitted to mechanical cycling, three fractured, being equivalent to 8,33%. Thirty three cycled retention screws, 12 new screw, being 6 for the CM connection and 6 for EH, were submitted to the compression strength test. The new screws showed the highest average for maximum strength (116,80 kgf) and deformation at full strength (2,18 mm), with a statistically significant difference (p <0.05) when compared with the cycled screws. Comparing the types of connection, the screws of the external hexagon connection groups had the highest mean maximum force (MF). Of the 12 new screws, 6 fractured during the test, being 3 of each type of connection. As for the cycled screws, there was the same amount of fracture, being 3 for the Morse Taper connection and 3 for the external hexagon. The highest average for fracture strength (FS) also occurred on the new screws. It was concluded that the mechanical cycling and different insertion torque values, which are lower than recommended by the manufacturer, negatively interfered on the preload maintenance of the retention screws of bolted joints in the evaluated conditions and although the screws submitted to cycling have presented a lower tensile strength average, the difference found did not present statistical power that would prove their influence on fracture of the tested retention screws. / CNPq: 130646/2014-8
158

Prótese óculopalpebral com captação de movimento palpebral: proposta de dispositivo mecânico / Oculopalpebral prosthesis with eyelid motion capture: mechanical appliance proposition

Lívia Morelli Vieira 08 April 2016 (has links)
Introdução: A reconstrução de grandes defeitos da face nem sempre é passível de correção cirúrgica, podendo ser restaurados com as próteses faciais. Apesar da prótese óculopalpebral apresentar uma aparência natural, ela é facilmente notada, pois não apresenta os movimentos palpebrais de abertura e fechamento sincronizadas com o olho contralateral, tornando assim a reconstrução protética um grande desafio. Objetivos: Planejar, desenhar, viabilizar e construir um protótipo com recurso mecânico/elétrico possibilitando sincronia dos movimentos palpebrais com o olho sadio para utilização em prótese óculopalpebral. Material e Métodos: Confecção de uma prótese óculopalpebral com um dispositivo de pálpebra móvel em silicone médico capaz de conectar-se a um sistema mecânico-elétrico responsável por realizar movimentos de abertura e fechamento da pálpebra móvel da prótese. Resultados e Discussão: Foi confeccionada uma prótese óculo-palpebral em resina acrílica termicamente ativada, criando-se um nicho para a acomodação de um sistema elétrico e possibilitar a livre movimentação de uma fina pálpebra em silicone interligada ao dispositivo tornando possível a conexão desse sistema com um sensor que capta o movimento palpebral de um olho saudável. Conclusão: No presente estudo um protótipo mecânico - elétrico foi planejado, desenhado e desenvolvido acoplado a uma prótese óculopalpebral estabelecendo e sincronizando seus movimentos palpebrais com o olho sadio. / Introduction: Surgical reconstruction of large facial defects may not be always possible. Extraoral maxillofacial prosthesis are a good restorative option. Even though when the oculopalpebral prosthesis presents a natural appearance, it can be easily noticed because its eyelids do not move. It is desirable for the eyelids to open and close synchronously with contralateral eye. Thus, prosthetic reconstruction of oculopalpebral region is a great challenge. Objectives: To plan, design, enable and build a oculopalpebral prosthesis prototype with mechanical and electric features allowing eyelid motion with synchronization with the sound eye. Material and method: Fabrication of an oculopalpebral prosthesis with a medical grade silicone movable eyelid which has the capability to connect itself to an mechanical-eletrical system responsible to make opening and closing movements on prosthesis movable eyelid. Results and discussion: An oculopalpebral prosthesis was made in thermoactivated acrylic resin. A gap was created to accomodate an electrical system and also allow free motion of a thin silicone eyelid attached to the dispositive. This system can be connected to a sensor which captured the eyelid motion of a sound eye. Conclusion: A mechanical-electrical prototype was planned, designed and developed attached to an oculopalpebral prosthesis stablishing and synchronizing its eyelid movements with the sound eye.
159

Avaliação da distribuição das tensões ao redor de implantes em diferentes níves de inserção / Stress distribution around dental implants placed at different depths: a photoelastic evaluation

Piero Rocha Zanardi 16 February 2017 (has links)
A perda óssea progressiva ao redor da plataforma dos implantes dentários é um desafio a ser vencido na clínica, uma vez que, interfere na manutenção e controle dos tecidos peri-implantares e pode afetar a estética. Esta pesquisa teve como objetivo avaliar a concentração de tensões ao redor de diferentes implantes dentários, variando a macrogeometria, conexão protética e profundidade da inserção da plataforma protética, sob carregamento axial ou oblíquo. Foram criados três modelos de resina fotoelástica para cada tipo de implante avaliado (hexágono externo, hexágono externo wedge, hexágono interno e cone Morse). Cada corpo de prova se diferenciou pelo posicionamento da plataforma do implante em relação à margem superior do bloco, em três posições diferentes: I - plataforma posicionada 2mm abaixo da margem do bloco; II - plataforma posicionada no mesmo nível da margem do bloco; III - plataforma posicionada 2mm acima da margem do bloco. Foi aplicada uma força de 100N através de um dispositivo instalado sobre pilares retos e angulados, simulando um carregamento axial e oblíquo respectivamente. Um total de 4 pontos foram avaliados de um lado do implante. Dados quantitativos foram coletados e utilizados para análise estatística. A regressão linear múltipla mostrou relação entre a distribuição das tensões com relação à profundidade de inserção independentemente do tipo de conexão protética ou do carregamento oclusal. O grupo I (2mm abaixo da margem) foi o que apresentou os menores valores (p<0.05) de tensão quando comparado com os outros grupos (II e III). De acordo com as limitações deste estudo pode-se concluir que a macrogeometria, profundidade de inserção da plataforma e tipo de carregamento oclusal influenciam no comportamento da distribuição das tensões ao redor dos implantes. Em relação à conexão protética, os resultados mostraram padrões de franjas semelhantes independentemente do tipo de conexão / The progressive bone loss at the neck of dental implant is a clinical concern since it affects the maintenance of dental esthetics. The stress concentration, the connection type and the microgap appear to be factors that cause alterations at the marginal bone level. The aim of this research was to evaluate the stress concentration around different dental implants, varying the macrogeometry, prosthetic connection and depth of the insertion of the prosthetic platform, under axial or oblique loading. Three blocks of photoelastic resin for each type of implant connection (external hexagon, external hexagon flattened, internal hexagon and Morse taper) were built. Each block differed in the position of the implant platform in relative to the upper margin of the block: I (2mm below), II (at the same level) and III (2mm above). A force of 100N was applied to both a straight and tilted abutments. A multiple linear regression showed the relation between the stress distribution and the insertion depth. For all the implant types, both with straight and tilted abutments, Group I presented the lowest stress concentration around the fixture when compared to group II and III (p<0,05). According to the limitations of this study it could be concluded that the macrogeometry, depth of insertion of the platform and type of occlusal loading influence the behavior of the distribution of stresses around the implants. Regarding the prosthetic connection, the results showed similar patterns of fringes regardless of the type of connection
160

Mechanická protéza horní končetiny / Mechanical upper limb prosthesis

Koukal, Ondřej January 2014 (has links)
This thesis elaborates on design and fabrication of an artificial mechanical upper limb prototype for transradial amputations, i. e. for patients with stump between elbow and wrist joints. The artificial limb is designed for use in a wide spectrum of patients. Therefore, the main components are designed to be applicable to smaller as well as larger hand dimensions. The artificial mechanical limb is designed to be controlled by the other hand of a patient and enables grasping of objects via cylindrical and hook grip. Fingers are driven by tension springs and can be locked in extension. Clenching can be initiated by pressing a button, which unlocks the fingers, thus an object can be grasped. Wrist joint is adjustable when pressed a release button. Forearm joint is locked by preloaded spring. The lock of the forearm joint is released by sufficient torque. New position of the forearm joint is locked automatically when the torque is not being applied. Prototypes of the artificial mechanical upper limb were manufactured by using of rapid prototyping technologies (FDM, SLM) as well as CNC milling machine. All parts of the artificial limb were designed with regard to manufacturability by conventional methods such as casting, injection and the like. The artificial limb prototype had been designed on 3D data basis of a specific patient, who already has tested the prototype. Following materials were used on the prototype: ABS plastic, SikaBlock M940 polyurethane, aluminium and 316L stainless steel.

Page generated in 0.0516 seconds