• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 4
  • Tagged with
  • 11
  • 11
  • 7
  • 5
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Biological aspects on synovial fluid mediated aseptic prosthesis loosening /

Andersson, Martin, January 2005 (has links)
Diss. (sammanfattning) Stockholm : Karol. inst., 2005. / Härtill 4 uppsatser.
2

On loosening and revision in total hip arthroplasty /

Eisler, Thomas, January 2003 (has links)
Diss. (sammanfattning) Stockholm : Karol. inst., 2003. / Härtill 6 uppsatser.
3

Heterotopic ossification : clinical and experimental studies on risk factors, etiology and inhibition by non-steroidal anti-inflammatory drugs /

Persson, Per-Erik, January 2004 (has links)
Diss. (sammanfattning) Uppsala : Univ., 2004. / Härtill 6 uppsatser.
4

In vitro evaluation of hip prostheses /

Anissian, H. Lucas, January 1900 (has links)
Diss. (sammanfattning) Stockholm : Karol. inst., 2001. / Härtill 5 uppsatser.
5

Dislocation of hip arthroplasty in patients with femoral neck fractures

Enocson, Anders, January 2009 (has links)
Diss. (sammanfattning) Stockholm : Karolinska institutet, 2009.
6

A new computed tomography method for evaluation of orthopedic implants applied to the acetabular cup

Olivecrona, Lotta, January 2010 (has links)
Diss. (sammanfattning) Stockholm : Karolinska institutet, 2010.
7

Influência do torque e da ciclagem mecânica na manutenção da pré-carga e resistência à fratura de parafusos de retenção em diferentes junções parafusadas / Influence of torque and mechanical cycling in preload maintenance and resistance to fracture of retaining screws in different implant-joints

Silva, Ebele Adaobi [UNESP] 17 June 2016 (has links)
Submitted by Ebele Adaobi Silva (silva.ebele@gmail.com) on 2016-08-11T15:23:23Z No. of bitstreams: 1 Dissertação_EbeleAdaobiSilva_Prótese.pdf: 1233295 bytes, checksum: 6ef711a36dbbc6aaf483494459874418 (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-08-11T18:16:49Z (GMT) No. of bitstreams: 1 silva_ea_me_araca.pdf: 1233295 bytes, checksum: 6ef711a36dbbc6aaf483494459874418 (MD5) / Made available in DSpace on 2016-08-11T18:16:49Z (GMT). No. of bitstreams: 1 silva_ea_me_araca.pdf: 1233295 bytes, checksum: 6ef711a36dbbc6aaf483494459874418 (MD5) Previous issue date: 2016-06-17 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Sendo o afrouxamento e fratura dos parafusos de retenção as principais complicações em próteses implantossuportadas, este estudo teve como objetivo avaliar a manutenção do torque remanescente e ocorrência de fraturas em parafusos de retenção de pilares UCLA, para implantes de conexão hexagonal externa e cone Morse, em função do torque aplicado (recomendado pelo fabricante, torque obtido através de aperto manual e sem torque), submetidos à ciclagem mecânica. Sequencialmente, investigou-se a resistência à fratura desses parafusos por meio do teste de compressão em uma máquina de ensaio universal. Foram utilizados 36 implantes embutidos em poliuretano com uma inclinação de 30°, divididos em 6 grupos em função do tipo de conexão e do torque aplicado. De forma randomizada, os espécimes pertencentes ao grupo sem torque foram submetidos a ciclagem mecânica e os dos grupos torque recomendado pelo fabricante e torque manual foram submetidos a aplicação do torque e mensuração da pré-carga remanescente, antes (3 minutos após o aperto) e após a ciclagem mecânica (após 1x106 de ciclos). Ao fim da ciclagem, os parafusos foram submetidos ao teste de resistência a fratura por meio do ensaio de compressão, no qual foi aplicado uma carga de 5000N sob a velocidade de 0,5mm/min. Os resultados mostraram que em uma análise geral, o torque remanesce foi significantemente menor (p<0,05) após a ciclagem mecânica. Ao se comparar os dois tipos de conexão, não houve diferença em relação o torque remanescente (p>0,05). Para os diferentes tipos de torque, observou-se que quando se aplicou o torque recomendado pelo fabricante o torque remanescente foi significativamente maior (p<0,05) quando comparada ao grupo que recebeu o torque manual. Dos 36 parafusos de retenção dos pilares UCLA submetidos à ciclagem mecânica, 3 fraturaram, equivalendo a 8,33%. Submeteu-se ao teste de resistência a compressão 33 parafusos de retenção ciclados e 12 novos, sendo 6 para a conexão CM e 6 para a HE. Os parafusos novos apresentaram as maiores médias para a força máxima (116,80 Kgf) e também para deformação na força máxima (2,18 mm), havendo diferença estatisticamente significativa (p<0,05) ao se comparar com os parafusos ciclados. Comparando-se os tipos de conexão, os parafusos dos grupos de conexão Hexágono externo apresentaram a maior média de força máxima (FM). Dos 12 parafusos novos, 6 fraturaram durante o teste, sendo 3 de cada tipo de conexão. Já para os parafusos ciclados, houve a mesma quantidade de fratura, sendo 3 para a conexão cone Morse e 3 para a Hexágono externo. A maior média para força de ruptura (FR) ocorreu também nos parafusos novos. Conclui-se então que a ciclagem mecânica e os diferentes valores de torque de inserção, sendo estes abaixo do que se recomenda o fabricante, interferiram negativamente nos valores de torque remanescente dos parafusos de retenção das junções parafusadas nas condições avaliadas e embora os parafusos submetidos a ciclagem tenham apresentado uma menor média de força de ruptura, a diferença encontrada não apresentou poder estatístico que comprovasse sua influência na fratura dos parafusos de retenção testados. / Being loosening and fracture of retention screws the main complications in implant-supported prostheses, this study aimed to evaluate the preload maintenance and the occurrence of fractures at retention screws of UCLA-type abutment for implants with external hexagon connection and Morse Taper, due to the applied torque (recommended by the manufacturer, torque obtained by manual tightening and no torque), submitted to mechanical cycling. Sequentially, the fracture resistance of these screws was investigated by the compression test on a universal testing machine. Thirty-six implants embedded in polyurethane with an inclination of 30° were used and divided into 6 groups according to the type of connection and the applied torque. Randomly, the specimens belonging to the group without torque underwent mechanical cycling and groups of recommended by the manufacturer torque and manual torque underwent torque application and measurement of the remaining preload, before (three minutes after tightening) and after mechanical cycling (after 1x106 cycles). After cycling, the screws were submitted to the fracture resistance test by the compression test, which was applied a 5000N load under 0,5 mm/min speed. The results showed that in a general analysis, preload maintenance was significantly lower (p <0,05) after mechanical cycling. When comparing the two types of connection, there was no difference regarding to preload maintenance (p>0,05). For different types of torque, it was observed that, when it was applied the recommended by the manufacturer torque, the preload maintenance was significantly higher (p <0,05) compared to the group that received the manual torque. Of the 36 retention screws of UCLA-type abutments submitted to mechanical cycling, three fractured, being equivalent to 8,33%. Thirty three cycled retention screws, 12 new screw, being 6 for the CM connection and 6 for EH, were submitted to the compression strength test. The new screws showed the highest average for maximum strength (116,80 kgf) and deformation at full strength (2,18 mm), with a statistically significant difference (p <0.05) when compared with the cycled screws. Comparing the types of connection, the screws of the external hexagon connection groups had the highest mean maximum force (MF). Of the 12 new screws, 6 fractured during the test, being 3 of each type of connection. As for the cycled screws, there was the same amount of fracture, being 3 for the Morse Taper connection and 3 for the external hexagon. The highest average for fracture strength (FS) also occurred on the new screws. It was concluded that the mechanical cycling and different insertion torque values, which are lower than recommended by the manufacturer, negatively interfered on the preload maintenance of the retention screws of bolted joints in the evaluated conditions and although the screws submitted to cycling have presented a lower tensile strength average, the difference found did not present statistical power that would prove their influence on fracture of the tested retention screws. / CNPq: 130646/2014-8
8

Coagulase-negative staphylococci in prosthetic hip infections /

Nilsdotter, Åsa, January 2005 (has links) (PDF)
Diss. (sammanfattning) Linköping : Linköpings universitet, 2005. / Härtill 5 uppsatser.
9

Avaliação da microestrutura óssea de sítios implantares e fatores relacionados às alterações no nível ósseo marginal e estabilidade de implantes dentários: estudo clínico prospectivo / Assessment of microstructure of jawbone sites and factors related to the changes on marginal bone level and dental implant stability: prospective clinical study

Dias, Danilo Rocha 15 July 2013 (has links)
Submitted by Jaqueline Silva (jtas29@gmail.com) on 2014-12-12T17:49:23Z No. of bitstreams: 1 Tese-Danilo Rocha Dias-2013.pdf: 12690993 bytes, checksum: 8af178ce9d242439a10d9aafdd18a329 (MD5) / Rejected by Jaqueline Silva (jtas29@gmail.com), reason: on 2014-12-12T17:49:32Z (GMT) / Submitted by Jaqueline Silva (jtas29@gmail.com) on 2014-12-12T19:43:01Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Tese-Danilo Rocha Dias-2013.pdf: 12690993 bytes, checksum: 8af178ce9d242439a10d9aafdd18a329 (MD5) / Approved for entry into archive by Jaqueline Silva (jtas29@gmail.com) on 2014-12-16T09:25:37Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Tese-Danilo Rocha Dias-2013.pdf: 12690993 bytes, checksum: 8af178ce9d242439a10d9aafdd18a329 (MD5) / Made available in DSpace on 2014-12-16T09:25:37Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Tese-Danilo Rocha Dias-2013.pdf: 12690993 bytes, checksum: 8af178ce9d242439a10d9aafdd18a329 (MD5) Previous issue date: 2013-07-15 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / Bone characteristics influence surgical/prosthetic planning of implant treatment, but it is not clear their influence on longitudinal outcomes. This study aimed to investigate the association between jawbone microstructure and changes on marginal bone level (MBL) and implant stability (IS) after loading, in a 1-year follow-up. Forty-one volunteers received 97 dental implants, installed in bone sites classified from 1 to 4, according to Leckholm & Zarb (1985). Cortical bone thickness was measured on computed tomography images. Histomorphometric and microtomographic analyses were performed in bone specimens obtained by using a trephine bur, at first drilling. Peak insertion torque (PIT) and implant stability quotient (ISQ) measured by resonance frequency analysis (RFA) were registered at implant insertion. Periapical radiographs were standardized to measure the MBL, and were taken at three moments, when the ISQ was also measured: at uncovering stage, at loading and at 1-year follow-up. Agreement analysis between histomorphometry and microcomputed tomography (microCT) showed that these methods are complementary, but not interchangeably. Association tests revealed that ISQ changes were not affected by MBL changes. Bone type 4 (according L&Z) presented higher changes on ISQ, especially during osseointegration. Microstructure parameters (histomorphometric and microCT parameters) and cortical thickness did not influence ISQ changes and MBL changes. These results suggest that bone characteristics influence primary implant stability, but do not predict implant success after osseointegration. / Características do tecido ósseo influenciam o planejamento cirúrgico/protético dos implantes dentários, mas não está clara sua relação com o resultado longitudinal do tratamento com implantes. O objetivo deste estudo foi investigar a associação entre microestrutura óssea de sítios implantares da maxila e mandíbula, as alterações de nível ósseo marginal (MBL) e a estabilidade dos implantes (IS) até o período de 1 ano após a aplicação de carga oclusal. Quarenta e um pacientes receberam 97 implantes dentários, instalados em sítios ósseos classificados como tipos 1 a 4, de acordo com a classificação de Leckholm & Zarb (1985). A espessura de osso cortical foi mensurada em imagens de tomografia computadorizada. Análises microtomográficas e histomorfométricas foram realizadas em espécimes ósseos obtidos com trefina na primeira perfuração para instalação dos implantes. Torque de inserção final (PIT) e quociente de estabilidade do implante (ISQ) medido por análise de freqüência de ressonância (RFA) foram registrados durante a instalação dos implantes. Radiografias periapicais padronizadas para mensuração do MBL foram obtidas em tres momentos, quando novos registros do ISQ foram também realizados: durante a cirurgia de reabertura, na instalação das próteses e 1 ano após aplicação da carga oclusal. A análise de concordância entre os métodos de microtomografia computadorizada (microCT) e histomorfometria, mostrou que estes métodos são complementares, mas não intercambiáveis. Testes de associação mostraram que as alterações na IS não foram afetadas pelas alterações no MBL. Ossos classificados como tipo 4 apresentaram as maiores alterações da IS, principalmente durante a osseointegração. Os parâmetros microestruturais (parâmetros microtomográficos e histomorfométricos) e a espessura de cortical não influenciaram as alterações de IS e do MBL. Estes resultados sugerem que as características do sítio ósseo influenciam a estabilidade primária, mas não são preditores do sucesso dos implantes após a osseointegração.
10

Avaliação da percepção auditiva da fala em pacientes submetidos ao reimplante coclear / Evaluation of auditory speech perception in patients submitted to cochlear reimplantation

Costa, Lucas Bevilacqua Alves da 18 July 2018 (has links)
Estudo retrospectivo, descritivo e longitudinal realizado na Seção de Implante Coclear, Centro de Pesquisas Audiológicas do Hospital de Reabilitação de Anomalias Craniofaciais da Universidade de São Paulo (IC-CPA/HRAC/USP). O objetivo deste estudo foi caracterizar o desempenho da percepção auditiva da fala de indivíduos submetidos à cirurgia de reimplante coclear. No total de 1.323 indivíduos submetidos à cirurgia de implante coclear no período de 1990 a janeiro de 2016, consta o registro de 84 indivíduos submetidos à cirurgia de reimplante coclear, correspondendo a 6,3% do total. Deste total de 84, 68 indivíduos atenderam aos critérios de inclusão/exclusão da pesquisa e foram avaliados utilizando-se testes de percepção auditiva da fala, em três momentos: antes da segunda intervenção cirúrgica, após o reimplante e última avaliação de acompanhamento. As variáveis estudadas foram: a) motivo do reimplante coclear; b) etiologia da perda auditiva; c) idade na primeira cirurgia; d) tempo de uso do implante coclear antes do reimplante; e) tempo de recuperação do escore anterior à intervenção; f) tempo de uso atual; g) escore nos procedimentos de avaliação da percepção auditiva da fala, pré e pós-reimplante coclear. Na análise dos dados foi possível observar que a causa mais comum do reimplante foi a falha do dispositivo interno, seguido de razões médicas. Na avaliação auditiva da fala, um total de 61 (89,7%) recuperaram o desempenho observado antes do reimplante coclear e sete (10,3%), não alcançaram o mesmo desempenho. Constatou-se que as variáveis idade do primeiro Implante e tempo de uso do primeiro Implante Coclear, assim como tempo de reimplante, influenciaram nos resultados encontrados. A cirurgia de reimplante coclear é um procedimento viável, contudo a família e o paciente devem ser orientados quanto aos possíveis comprometimentos na percepção auditiva da fala / A retrospective, descriptive and longitudinal study performed in the Cochlear Implant Section, Audiological Research Center of the Hospital of Rehabilitation of Craniofacial Anomalies of the University of São Paulo (IC-CPA / HRAC / USP). This study aimed at characterizing the auditory speech perception of individuals undergoing cochlear reimplantation surgery. Out of 1,323 individuals undergoing cochlear implant surgery from 1990 to January 2016, 84 (6.3%) subjects underwent cochlear reimplantation surgery. From this total of 84, 68 individuals met the inclusion / exclusion criteria of the study and were evaluated using auditory speech perception tests in three moments: before the second surgical intervention, after reimplantation and the last follow-up evaluation. The variables studied were: a) reason for cochlear reimplantation; b) etiology of hearing loss; c) age at first surgery; d) time cochlear implant use before reimplantation; e) recovery time from the previous intervention score; f) time of current use; g) score in the procedures of assessment of auditory speech perception before and after cochlear reimplantation. The data analysis showed that the most common cause of reimplantation was the failure of the internal device, followed by medical reasons. In the auditory speech evaluation, a total of 61 (89.7%) recovered performance before cochlear reimplantation, and seven (10.3%), did not reach the same performance. It was verified that the variables age at the first Implant and time using the first Cochlear Implant, as well as time of reimplantation, influenced the results. Cochlear replantation surgery is a viable procedure, however, the family and the patient should be advised on the possible compromising risks to the auditory speech perception

Page generated in 0.0634 seconds