• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 21
  • 3
  • Tagged with
  • 26
  • 26
  • 16
  • 14
  • 14
  • 13
  • 13
  • 11
  • 10
  • 9
  • 8
  • 8
  • 8
  • 8
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Etude du comportement mécanique de la glène pour la mise au point d'un nouvel implant scapulaire à fixation sans ciment / Study of the mechanical properties and behaviour of glenoid cancellous bone for the development of a new glenoid implant with cementless fixation

Kalouche, Ibrahim 19 September 2011 (has links)
Les prothèses totales d’épaule ont une survie limitée due essentiellement au descellement de l’implant scapulaire. Le but de ce travail de recherche est la contribution à la mise au point d’un nouvel implant scapulaire à fixation sans ciment.Une première partie a concerné la caractérisation de l’anisotropie et des hétérogénéités de l’os spongieux de la glène par une expérimentation en compression, cette partie a abouti à l’élaboration d’une loi de comportement de l’os spongieux de la glène. La seconde partie de ce travail s’est focalisée sur la modélisation par éléments finis des contraintes aux points d’ancrage de l’implant.Les résultats des tests de simulation montrent l’incapacité du spongieux à assurer un effet press-fit dans le plan transversal, car on observe le dépassement des contraintes maximales pour un déplacement minime. Ce résultat met en question les modes de fixation primaire utilisés ce jour dans les prothèses sans ciment. Nos résultats montrent que la modification de la direction de chargement serait susceptible d’améliorer la fixation primaire ce qui ouvre des perspectives nouvelles pour le dessin d’une prothèse sans ciment. / Total shoulder prostheses have a limited survival due mainly to the loosening of the glenoid implant. The purpose of this research is the contribution to the development of a new glenoid implant with cementless fixation.The first part concerned the characterization of the anisotropy and heterogeneity of cancellous bone of the glenoid by a compression experimental tests, this part has led to the drafting of a law of behavior of cancellous bone of the glenoid . The second part of this work has focused on finite element modeling of stress around the anchors of the glenoid implant.Simulation test results show the inability of the transversal plane of the glenoid to ensure effective press-fit fixation with stresses above strength properties of the cancellous bone with a minimal displacement. This calls into question the current modes of primary fixation of cementless implant. However, it appears that a change in the direction of loading would be beneficial for the primary fixation, which opens new perspectives for the design of a cementless prosthesis.
12

Influence des défauts de forme sur les performances d'assemblages : application aux prothèses totales de hanche / Influence of form errors on assemblies performance : application on total hip implants

Grandjean, Julien 29 October 2013 (has links)
La performance des mécanismes est intimement liée à la précision des surfaces qui composent les liaisons. La démarche habituelle de l’analyse de ces surfaces est basée sur des hypothèses fortes concernant leurs comportements. Ainsi, les défauts de forme et de rugosité sont négligés et les surfaces sont supposées infiniment rigides. L’objectif principal de ces travaux est de développer une méthode permettant d’étudier l’influence des défauts de forme sur les performances des assemblages. Elle repose sur une méthodologie et des outils pour l’identification des défauts qui vont optimiser ou pénaliser les exigences fonctionnelles de l’assemblage. Dans ce manuscrit, deux cas d’étude sont proposés.Dans un premier temps, un montage de type bride (centrage court, appui plan) est étudié afin de valider l’ensemble de la démarche développée. Les outils utilisés reposent essentiellement sur la décomposition et composition modale des défauts, le concept de surface écarts, la recherche de zone d’appui stable ainsi que la quantification des déformations de surfaces de contact basées sur des modèles analytiques ou numériques. L’influence des défauts de forme sur la précision de mise en position est quantifiée par un domaine écart de liaison. Une confrontation entre la démarche théorique et un dispositif expérimental permet de valider l’approche. Par la suite, une liaison sphérique est considérée constituant une prothèse totale de hanche en matériau céramique. Pour ce cas d’étude, l’objectif est d’identifier, au regard des typologies de défauts, leurs conséquences sur l’apparition d’un phénomène sonore assimilable à du grincement appelé le squeaking. La démarche reprend les mêmes étapes que celles utilisées avec l’étude de la bride. Différents dispositifs expérimentaux sont mis en place confirmant la pertinence de cette approche. Des mesures spécifiques apportent des éléments d’analyse et de compréhension sur le comportement dégradé de la liaison. Ce travail de thèse s’inscrit dans une collaboration entre 3 laboratoires : SYMME d’Annecy, I2M-IMC de Bordeaux-Talence, et la société Tural localisée à Marignier (74), laboratoire de recherche industrielle qui travaille sur des implants médicaux. / The performance of a mechanism is closely correlated with the accuracy of the surfaces that make up the mechanical joint. The most common approach used to study these surfaces is based on strong assumptions about their behavior. Form errors and roughness are neglected and the surfaces are assumed infinitely rigid. The main objective of this work is to develop an original approach to study the impact of form errors on the assemblies. It is mainly based on a methodology and associated tools to predict which defects will optimize or penalize the functional requirements of the assembly. In this manuscript, two case studies are proposed. In a first step, a plate flange (ball and cylinder joints added to a planar joint) is designed to validate the overall approach. Modal decomposition of defects, sum-surface concept, the determination of a stable contact area and quantification of contact deformation of surfaces correspond to the main theoretical tools used in this framework. The influence of form errors on the positioning accuracy is quantified by a clearance domain. Comparisons between theoretical approach and experimental setup are used to validate the models. Subsequently, a spherical joint is considered corresponding to a total hip implant with ceramic material. The objective of this study is to identify which type of form errors can impact the appearance of the squeaking phenomena. The same procedure is followed as for the first example. In parallel, several experimental devices are designed to validate the relevance of this approach. Specific measurements provide some key elements to understand the behavior of the implant subject to squeaking. This work is part of a collaboration between three laboratories : SYMME Annecy, I2M-IMC Bordeaux, and Tural company located in Marignier (74), an industrial research laboratory working on medical implants.
13

Tribologie et vieillissement de prothèses totales de hanche en biocéramique, in vitro = in vivo ? Enjeux scientifique et sociétal / Tribology and ageing of bioceramic total hip prostheses, in vitro = in vivo? Scientific and societal issues

Perrichon, Armelle 20 January 2017 (has links)
La performance du couple prothétique tête fémorale/cupule impacte fortement la durée de vie d’une prothèse totale de hanche. Les céramiques affichent une excellente combinaison de propriétés de biocompatibilité, mécaniques et tribologiques. Les composites ZTA formés d’une matrice d’alumine renforcée en zircone sont optimisés pour offrir le meilleur compromis de dureté, stabilité chimique, ténacité et résistance mécanique. La prédiction de la performance de ces matériaux doit prendre en compte les trois principaux modes de dégradation identifiés en configuration céramique/céramique (CoC) : le choc avec décoaptation, le frottement et le vieillissement à basse température. Ces modes sont susceptibles d’être simulés in vitro à partir de tests expérimentaux, respectivement, sur une machine de chocs, un simulateur de marche et en autoclave. L’objectif de ce projet est de combiner ces tests afin de mieux résoudre l’équation in vitro = in vivo. Les chocs dominent les processus de dégradation avec la formation de bandes d’usure. Le matériau testé a montré une excellente résistance au vieillissement. La dégradation induite par le test d’usure standard sur simulateur de marche est négligeable et pose la question de la pertinence de ce test pour les couples CoC. L’importance de la prise en compte des chocs dans les tests expérimentaux a été confortée grâce à une analyse d’explants. Une transformation de phase de la zircone a été mécaniquement induite dans les bandes d’usure créées in vitro et in vivo. Un mécanisme de dégradation a été suggéré au sein de ces bandes. La réponse du matériau est en partie déterminée par la force appliquée au cours des chocs. / The performance of the prosthetic couple (femoral head/cup) influences strongly the lifetime of a total hip prosthesis. Ceramics exhibit an excellent combination of biocompatibility, mechanical resistance and tribological properties. Zirconia toughened alumina (ZTA) composites are made of an alumina matrix and well dispersed zirconia particles. They are tailored in order to offer the best compromise of hardness, chemical stability, toughness and mechanical resistance. The prediction of the performance of such materials must take into consideration the three main sources of degradation identified for Ceramic-on-Ceramic (CoC) bearings: shocks due to micro-separation, friction and low temperature degradation (LTD). Experimental tests on a shock machine, a hip-walking simulator and in an autoclave are able to simulate in vitro each of these sources of degradation, respectively. The aim of the project is to combine these tests in order to solve better the equation in vitro = in vivo. Shocks dominate the processes of degradation with the formation of wear stripes. The tested material showed an excellent resistance to LTD. The damage induced by the standard wear test on a hip-walking simulator is negligible, which raises the question about the relevance of this test for CoC couplings. An analysis of explants confirmed the decisive role of shocks in experimental tests. Zirconia phase transformation was mechanically induced within both in vitro and in vivo wear stripes. A degradation mechanism was suggested within the stripes. The material response is partly determined by the force applied during shocks.
14

Relation entre la satisfaction et la qualité de vie reliée à la santé bucco-dentaire chez les patients totalement édentés

Michaud, Pierre-Luc 06 1900 (has links)
Problématique : La satisfaction des patients et la qualité de vie reliée à la santé bucco-dentaire (OHRQoL) sont deux mesures de résultats fréquemment utilisées durant les études cliniques. Néanmoins, chez les patients totalement édentés, les évidences scientifiques relatives au niveau de relation entre ces deux mesures sont faibles. De plus, on ignore toujours quels éléments de la satisfaction des patients relativement à leurs prothèses partagent la meilleure relation avec la OHRQoL. Objectifs : Déterminer, chez les patients totalement édentés, s’il existe un lien entre leur satisfaction de leurs prothèses et leur OHRQoL et identifier les déterminants de satisfaction qui démontrent le meilleur niveau de relation avec la OHRQoL. Méthodologie : Les données provenant de 255 patients totalement édentés qui ont participé à une étude randomisée et contrôlée ont été utilisées. La OHRQoL a été évaluée à l’aide du questionnaire Oral Health Impact Profile (OHIP-20). Le McGill Denture Satisfaction Instrument a été utilisé pour estimer la satisfaction des patients. Ces mesures ont été prises au temps initial, à 6 mois et à 12 mois suivants la mise en bouche des prothèses. Des analyses statistiques de régression linéaire simples et multiples ont été utilisées afin d’évaluer la relation entre les deux mesures. Résultats : Une relation positive et considérable existe entre la satisfaction des patients totalement édentés et leur OHRQoL. La difficulté masticatoire (P = .005) et la condition buccale (P = .002) sont les éléments de la satisfaction qui possèdent le meilleur lien avec la OHRQoL. Ces deux facteurs expliquent 46.4% (P = .0001) de la variance dans l’amélioration d’OHIP suivant un traitement prosthodontique. La relation décrite est dépendante du temps, mais pas du type de traitement ni des variables sociodémographiques. Conclusions : Dans les limites de l’étude, il est conclu qu’une relation positive existe entre la satisfaction des patients et leur OHRQoL. La difficulté masticatoire et la condition buccale sont les deux éléments de la satisfaction les plus importants. / Statement of problem: Patients’ satisfaction and oral health-related quality of life (OHRQoL) are two commonly used patient-reported outcomes. Convincing evidence is lacking to demonstrate the relation between these two outcomes in completely edentate patients who receive prosthodontic treatments. In addition, it is still unclear which elements of denture satisfaction share the best association with OHRQoL. Objectives: To evaluate the level of association between patients’ denture satisfaction and OHRQoL in edentulous patients, and to identify the determinants of satisfaction that best predict OHRQoL. Methods: Data from 255 edentulous elders who participated in a randomized clinical trial were used to analyze the relationship between OHRQoL and denture satisfaction. OHRQoL was evaluated with the Oral Health Impact Profile (OHIP-20) questionnaire. The McGill Denture Satisfaction Instrument was used to assess patients’ satisfaction with treatment. Outcomes were measured prior to treatment and 6 and 12 months after delivery of new dentures. Simple and multiple linear regressions analyses were performed to statistically assess the relationship between the variables. Results: A highly positive association exists between oral health-related quality of life and denture satisfaction ratings. Chewing ability (P = .005) and oral condition (P = .002) are the aspects of satisfaction presenting the best association with OHRQoL. These two variables explained 46.4% (P = .0001) of the variance in OHIP’s change score following treatment. This association varied with time, but not with type of treatment or socio-demographic variables. Conclusions: Within the limitations of this study, a highly positive association exists between OHRQoL and denture satisfaction. Chewing ability and oral condition are the determinant of denture satisfaction best associated with OHRQoL, predicting 46.4% of its improvement following a treatment.
15

Évaluation biomécanique de la locomotion à la suite d'une arthroplastie de la hanche

Bouffard, Vicky 04 1900 (has links)
Depuis les dernières années, la prévalence de personnes souffrant de dégénérescence des cartilages articulaires, communément appelée ostéoarthrite (OA), ne cesse d’augmenter. Les douleurs articulaires et les raideurs musculaires associées à cette pathologie mènent à des limitations des capacités fonctionnelles, à une perte de mobilité et d’autonomie affectant grandement la qualité de vie de ces personnes. Afin de soulager les personnes souffrant de cette pathologie, l’arthroplastie de la hanche est une procédure chirurgicale fréquemment utilisée. À la suite de cette chirurgie, une amélioration de la qualité de vie et une reprise des capacités fonctionnelles sont souvent observées. Cependant, comparativement à des sujets sains, la vitesse de marche est diminuée, une faiblesse des muscles abducteurs de la hanche est constatée et des mouvements compensatoires au niveau du tronc sont persistants. L’objectif de cette thèse est d’évaluer le patron locomoteur chez des patients qui subiront une arthroplastie de la hanche. Plus spécifiquement, les adaptations locomotrices pré et post-opératoires seront quantifiées dans le but d’apporter des modifications aux programmes de réhabilitation pour ainsi favoriser un patron locomoteur sans déficit. Afin de répondre à cet objectif, trois études distinctes ont été effectuées. Dans le cadre de la première étude, l’impact de l’implantation d’une prothèse totale de la hanche avec une tête fémorale de large diamètre et une prothèse de resurfaçage a été évalué par rapport aux sujets sains lors de la locomotion. Au cours de cette étude, le contrôle du tronc a été analysé en utilisant la distance entre le centre de masse corporel et le centre articulaire de la hanche opérée. Suite aux résultats obtenus, aucune différence majeure n’existe entre les deux types de prothèses en ce qui a trait au contrôle du tronc et ce, à un an post-opératoire. Lors de la deuxième étude, la symétrie des paramètres biomécaniques des membres inférieurs lors de la locomotion chez des patients ayant bénéficié de l’implantation d’une prothèse de la hanche a été caractérisée suite à un programme d’exercices péri-opératoires (pré et post-opératoire). Lors de cette étude, le programme d’exercices péri-opératoires était complémentaire au protocole de réadaptation du centre hospitalier. D’après les résultats obtenus lors de cette étude exploratoire, ce programme d’exercices péri-opératoires semble permettre d’améliorer la symétrie de la puissance et du travail musculaire au niveau de la hanche, du genou et de la cheville favorisant ainsi un patron de marche avec de minimes compensations. Finalement, dans le cadre de la troisième étude, l’approche prédictive et l’approche fonctionnelle, utilisées pour localiser le centre articulaire de la hanche, ont été comparées aux mesures radiographiques, chez des patients à la suite d’un remplacement articulaire de la hanche. À la suite de cette étude, les résultats démontrent que l’utilisation de l’approche fonctionnelle est plus appropriée chez des patients ayant bénéficié d’une arthroplastie de la hanche. En effet, cette approche individualisée est plus précise ce qui, par conséquent, permettra d’obtenir des résultats de plus grande qualité lors d’analyses biomécaniques de la locomotion. / In recent years, the prevalence of people suffering from joint cartilage degeneration, called osteoarthritis (OA), still increases. The joint pain and muscle stiffness related to this pathology have an impact on patients’ quality of life by limiting their functional capacities, mobility and autonomy. In order to relieve these patients, hip arthroplasty is a frequently used surgical procedure. Even if there is an improvement in quality of life and a restoration of functional capacities in these patients, some impairment seem to persist during the post-operative period. The walking velocity is slower when compared to healthy subjects, a hip abductor muscle weakness is observed and trunk compensations lasted during the post-operative period. The aim of this thesis is to evaluate patients undergoing hip arthroplasty during locomotion. More specifically, gait pattern adaptations will be quantified pre and post-operatively to revise rehabilitation programs in order to promote a healthy gait pattern. Three separate studies were conducted to meet this objective. The first study compared the effect of a large femoral head hip prosthesis and a hip resurfacing prosthesis to healthy subjects. During this study, the trunk control was analyzed using the distance between the body center of mass and the hip prosthetic joint center. The results obtained show no major difference between the two types of prosthesis and the healthy control one year post-operatively. During the second study, biomechanics parameter symmetry of the lower limb of gait pattern in patients undergoing hip arthroplasty was characterized following a peri-operative (pre and post-operatively) exercise program. The exercise program was complementary to the medical center standard rehabilitation program. Based on the results of this exploratory study, the peri-operative exercise program seems to improve the symmetry of the muscular power and work of the hip, knee and ankle which promote a healthy gait pattern without compensations. Finally, for the third study, the predictive and the functional approaches, used to locate the hip joint center, were compared to radiographic measurements in patients undergoing hip arthroplasty. The results of this study demonstrated that the functional approach was more appropriate for these patients. This individualized approach is more accurate which leads to quality improvement during biomechanical analysis of gait pattern.
16

La survie implantaire suite à une réhabilitation par mise en charge immédiate d’une prothèse totale mandibulaire reliée à deux implants non jumelés : une étude pilote expérimentale

Audy, Nicholas 04 1900 (has links)
Problématique : Les connaissances théoriques et pratiques au sujet de la mise en charge immédiate d’implants non jumelés chez les édentés sont limitées. Objectifs : Cette étude avait pour but de : (1) déterminer le taux de survie implantaire de 2 implants non jumelés supportant une prothèse totale mandibulaire suite à une mise en charge immédiate, (2) évaluer les changements des niveaux osseux et de stabilité implantaire survenus sur ces 2 implants durant une période de 4 mois et les comparer à un implant témoin, et (3) décrire les complications cliniques associées à ce mode de mise en charge. Méthodologie : Chez 18 individus édentés (âge moyen de 62±7 ans), cette étude de phase I avec un design pré/post a évalué les résultats cliniques suivant la mise en charge immédiate (<48 heures) de 2 implants non jumelés par une prothèse totale mandibulaire. À l’aide de radiographies périapicales, de sondages osseux et d’analyses de la fréquence en résonnance, les niveaux osseux péri-implantaires (en mm) et les niveaux de stabilité implantairte (en ISQ) de ces 2 implants insérés dans la région parasymphysaire ont été évalués à la chirurgie (T0) et au suivi de 4 mois (T1). Un implant non submergé et sans mise en charge inséré dans la région de la symphyse mandibulaire a été utilisé comme témoin. Les données ont été analysées avec des modèles mixtes linéaires, la méthode de Tukey ajustée, l’analyse de variance de Friedman et des tests de rang signés de Wilcoxon. Résultats : De T0 à T1, 3 implants mis en charge immédiatement ont échoué chez 2 patients. Le taux de survie implantaire obtenu était donc de 91,7% (33/36) et, par patient, de 88,9% (16/18). Aucun implant témoin n’a échoué. Les changements osseux documentés radiologiquement et par sondage autour des implants mis en charge immédiatement étaient, respectivement, de -0,2 ± 0,3 mm et de -0,5 ± 0,6 mm. Les pertes d’os de support implantaire n’ont pas été démontrées statistiquement différentes entre les implants avec mise en charge immédiate et les témoins. Les niveaux moyens de stabilité implantaire ont augmenté de 5 ISQ indépendamment de la mise en charge. Les niveaux moyens d’ISQ n’ont pas été démontrés statistiquement différents entre les implants avec mise en charge immédiate et les témoins à T0 ou T1. Cinq des 18 patients n’ont expérimenté aucune complication clinique, alors que 9 en ont eu au moins deux. Hormis les échecs implantaires, aucune de ces complications n’a entraîné de changements au protocole. Conclusion : Les résultats à court terme suggèrent que : (1) le taux de survie implantaire suite au protocole immédiat est similaire à ceux rapportés lors d’un protocole de mise en charge conventionnel (2) les changements d’os de support implantaire et de stabilité ne sont pas différents comparativement à ceux d’un implant témoin, (3) un niveau élevé d’expérience clinique et chirurgicale est requis pour effectuer les procédures et pour gérer les complications associées. Ces résultats préliminaires devraient être confirmés dans une étude clinique de phase II. / Problem: There is a theoretical and practice knowledge gap in regard to immediate loading of unsplinted implants in edentulous individuals. Objectives: This study aimed to: (1) determine the implant survival rate of 2 unsplinted implants supporting a mandibular complete overdenture following an immediate loading protocol, (2) assess marginal bone level and implant stability changes of these immediately loaded implants in a 4-month period and compared them to a control implant, and (3) describe the clinical complications associated with this mode of loading. Methods: In 18 edentate individuals (mean age 62±7 years), this phase-I trial with a pre/post design assessed the clinical outcomes following the immediate loading (<48 hours) of 2 unsplinted implants supporting a mandibular overdenture. Periapical radiograhs, bone probing measurements and resonance frequency analysis were used to assess marginal bone losses and implant stability changes of these two implants inserted in the mandibular parasymphyseal region, at baseline (T0) and 4-month follow-up (T1). A non-submerged and non-loaded implant inserted in the mandibular symphysis was used as a control. Data were analyzed using linear mixed models, adjusted Tukey tests, Friedman’s analysis of variance and Wilcoxon signed-ranks tests. Results: From T0 to T1, 3 immediately loaded implants failed in 2 patients. This resulted in an implant survival rate of 91.7% (33/36), and, per patient, of 88.9% (16/18). No control implant failed. The marginal bone losses around loaded implants were -0.2 ± 0.3 mm for radiographic measurements and -0.5 ± 0.6 mm for probing measurements. There was no statistically significant difference between immediately loaded and control implants in regard to the supporting marginal bone losses. The implant stability levels increased of 5 ISQ units regardless of loading. There was no statistically significant difference in the mean ISQ levels between immediately loaded and control implants at T0 or T1. Five out of 18 patients experienced no clinical complication, while 9 of them had at least two. Apart from implant failures, none of these clinical complications led to changes in the protocol. Conclusion: The short-term results suggest that: (1) the implant survival rate following the immediate protocol is similar to those reported during a conventional loading protocol, (2) marginal implant supporting bone and stability changes are not different compared to those of a control implant, (3) a high level of clinical and surgical experience is required to perform the procedures and to manage the associated complications. These preliminary results should be confirmed in a phase II clinical trial.
17

Les attentes, la satisfaction et la qualité de vie des édentés suite à une réhabilitation par mise en charge immédiate d'une prothèse totale reliée à deux implants non jumelés : une étude pilote expérimentale

Menassa, Melanie 05 1900 (has links)
Problématique : La majorité des études publiées sur la réhabilitation par mise en charge immédiate de deux implants non jumelés avec une prothèse totale mandibulaire de recouvrement n’ont rapporté que des mesures cliniques objectives et très peu ont évalué les mesures centrées sur le patient, et ce, avec des erreurs de mesure. Aucune étude n’a évalué les attentes des patients vis-à-vis d'un tel protocole. Objectifs : Évaluer les attentes, le niveau de satisfaction ainsi que la qualité de vie reliée à la santé bucco-dentaire des édentés complets suite à un protocole de mise en charge immédiate. Méthodologie : Cet essai clinique de phase 1 utilise un design pré-post afin d’évaluer les mesures centrées sur le patient. Dix-huit individus, complètement édentés et âgés en moyenne de 62,39 ± 7,65 ans, ont reçu une prothèse totale mandibulaire de recouvrement sur deux implants non jumelés suite à un protocole de mise en charge immédiate, conjointement à une prothèse totale conventionnelle maxillaire. Un instrument adapté pour mesurer leurs attentes à l’aide d’échelles visuelles analogues, le questionnaire « McGill Denture Satisfaction Instrument » ainsi que le questionnaire OHIP-20 ont été remis aux patients avant de procéder aux traitements (T0), ainsi qu’aux rendez-vous de suivi à 2 semaines (T1), 1 mois (T2) et 4 mois (T3). De plus, l’inventaire de personnalité révisé (NÉO PI-R) ainsi qu’un questionnaire sociodémographique ont été remplis par les participants. Les « change scores » ont été calculés puis des tests non paramétriques et des analyses de variances en mesures répétées suivies de comparaisons par paires ont été utilisés afin d’analyser les données recueillies. La taille d’effet a été estimée. Résultats : Les participants avaient différentes attentes par rapport à la mise en charge immédiate. Certains s’attendaient à un effet positif à court terme par rapport à leur apparence esthétique (83,3 %) et à leur vie sociale (55,7 %), alors que d’autres avaient des craintes envers leur confort (5,6 %), leur habileté à mastiquer (11,1 %) et à nettoyer leur prothèse inférieure (11,1 %). À 4 mois, le protocole de mise en charge immédiate avait rencontré la majorité des attentes des patients par rapport à l’esthétique (94.4 %), la mastication (83.3 %), la phonétique (61.1 %), le confort (94.4 %), l’hygiène (88.9 %) et leur vie sociale (88.9 %). Une amélioration statistiquement significative de la satisfaction en générale, du confort, de l’esthétique, de la stabilité de la prothèse inférieure et de l’habileté à mastiquer a été notée à 2 semaines (p<0,001). Également, les comparaisons par paires ont révélé une diminution statistiquement significative du score total de l’OHIP-20 (p < 0,001) de même que la majorité des domaines de l’OHIP (p < 0.01), sauf pour l’handicap social qui n’a diminué significativement qu’après 1 mois (p = 0.01). Ces changements (pour la satisfaction et la qualité de vie) sont restés stables au cours des suivis subséquents. Indépendamment des traits de personnalité et des variables sociodémographiques, le protocole immédiat a satisfait 94,4 % des participants et a amélioré leur qualité de vie avec une large magnitude d’effet (d = 1.9; p < 0.001). Bien que deux patients aient perdu des implants au cours du traitement, 100 % des participants étaient d’accord pour recommander cette procédure à leurs pairs. Conclusions: Le protocole de mise en charge immédiate semble satisfaire les patients quelles que soient leurs attentes. Le protocole MCI peut améliorer, à court terme, la qualité de vie des patients totalement édentés. Les résultats prometteurs de la phase 1 devraient être corroborés lors de la 2e phase de cette étude. / Statement of problem: Most published research on the immediate loading of a mandibular 2-implant overdenture has only reported on clinical outcomes. Few studies have evaluated patients centered-outcomes but with measurement errors. Consequently, there is a need to assess clinical and patient-reported outcomes in this regard. Objectives: To examine patients’ level of satisfaction, expectations and quality of life with regard to the implants’ immediate loading protocol in edentate individuals. Methods: This phase-I trial used a pre-post design to assess patient-centered outcomes in 18 edentate individuals (mean age 62.39 ± 7.65 years) who have received a 2-implant (unsplinted) mandibular overdenture through an immediate loading protocol. The McGill Denture Satisfaction Instrument, a VAS instrument assessing expectations and the OHIP-20 questionnaire were used to evaluate patients’ outcomes at baseline, 2 weeks, 1 and 4 months. Socio-demographic and personality trait data were obtained using the Revised NEO Personality Inventory and a self-administered questionnaire. Change scores were calculated and non-parametrical tests were used to analyse the data. Repeated measures ANOVAs and paired t-tests were also conducted, and effect size was estimated. Results: The participants had a wide range of expectations regarding the immediate loading protocol. Expectations included short-term positive impact on aesthetics (83.3 %) and social life (55.7 %). Other expectations included negative effects on comfort (5.6%), the ability to chew (11.1 %) and to clean their lower denture (11.1%). At 4 months, the immediate loading protocol had met most patients’ expectations regarding aesthetics (94.4%), the ability to chew (83.3%), ability to speak (61.1%), comfort (94.4%), the ability to clean their lower denture (88.9%) and their social life (88.9%). The statistical analysis showed an overall satisfaction increase with a median change score of 66 (range=7-98), 68 (range=7- 95), and 70 (range= 17- 99), at 2 weeks, 1 month and 4 months respectively. There was a statistically significant improvement in overall satisfaction, comfort, perceived aesthetics, stability of the overdenture, and ability to chew at 2 weeks (p < 0,001). Pairwise comparison (within-subjects comparisons) revealed significant decreases in total OHIP scores (P < 0.001), as well as fewer functional limitations, physical pain, psychological discomfort, physical disability, psychological disability, and handicap (P < 0.01) from baseline to 2 weeks, 1 month and 4 months follow-up. Social disability score decrease significantly only after 1 month follow-up (p = 0.01). These changes remained stable during subsequent follow-ups. The protocol satisfied 94.4% of the participants and improve their quality of life with an estimated effect size of 1.9 (p < 0.001), regardless of socio-demographic and personality profiles. There was 100% agreement among patients on recommending this procedure to their peers. Conclusions: Immediate loading of two unsplinted implants with a mandibular overdenture seemed to fulfill patients’ satisfaction regardless of their expectations and may improve oral health-related quality life of edentate individuals in short-term. Encouraging results from phase I should be confirmed and approved in Phase II clinical trials.
18

La survie implantaire suite à une réhabilitation par mise en charge immédiate d’une prothèse totale mandibulaire reliée à deux implants non jumelés : une étude pilote expérimentale

Audy, Nicholas 04 1900 (has links)
Problématique : Les connaissances théoriques et pratiques au sujet de la mise en charge immédiate d’implants non jumelés chez les édentés sont limitées. Objectifs : Cette étude avait pour but de : (1) déterminer le taux de survie implantaire de 2 implants non jumelés supportant une prothèse totale mandibulaire suite à une mise en charge immédiate, (2) évaluer les changements des niveaux osseux et de stabilité implantaire survenus sur ces 2 implants durant une période de 4 mois et les comparer à un implant témoin, et (3) décrire les complications cliniques associées à ce mode de mise en charge. Méthodologie : Chez 18 individus édentés (âge moyen de 62±7 ans), cette étude de phase I avec un design pré/post a évalué les résultats cliniques suivant la mise en charge immédiate (<48 heures) de 2 implants non jumelés par une prothèse totale mandibulaire. À l’aide de radiographies périapicales, de sondages osseux et d’analyses de la fréquence en résonnance, les niveaux osseux péri-implantaires (en mm) et les niveaux de stabilité implantairte (en ISQ) de ces 2 implants insérés dans la région parasymphysaire ont été évalués à la chirurgie (T0) et au suivi de 4 mois (T1). Un implant non submergé et sans mise en charge inséré dans la région de la symphyse mandibulaire a été utilisé comme témoin. Les données ont été analysées avec des modèles mixtes linéaires, la méthode de Tukey ajustée, l’analyse de variance de Friedman et des tests de rang signés de Wilcoxon. Résultats : De T0 à T1, 3 implants mis en charge immédiatement ont échoué chez 2 patients. Le taux de survie implantaire obtenu était donc de 91,7% (33/36) et, par patient, de 88,9% (16/18). Aucun implant témoin n’a échoué. Les changements osseux documentés radiologiquement et par sondage autour des implants mis en charge immédiatement étaient, respectivement, de -0,2 ± 0,3 mm et de -0,5 ± 0,6 mm. Les pertes d’os de support implantaire n’ont pas été démontrées statistiquement différentes entre les implants avec mise en charge immédiate et les témoins. Les niveaux moyens de stabilité implantaire ont augmenté de 5 ISQ indépendamment de la mise en charge. Les niveaux moyens d’ISQ n’ont pas été démontrés statistiquement différents entre les implants avec mise en charge immédiate et les témoins à T0 ou T1. Cinq des 18 patients n’ont expérimenté aucune complication clinique, alors que 9 en ont eu au moins deux. Hormis les échecs implantaires, aucune de ces complications n’a entraîné de changements au protocole. Conclusion : Les résultats à court terme suggèrent que : (1) le taux de survie implantaire suite au protocole immédiat est similaire à ceux rapportés lors d’un protocole de mise en charge conventionnel (2) les changements d’os de support implantaire et de stabilité ne sont pas différents comparativement à ceux d’un implant témoin, (3) un niveau élevé d’expérience clinique et chirurgicale est requis pour effectuer les procédures et pour gérer les complications associées. Ces résultats préliminaires devraient être confirmés dans une étude clinique de phase II. / Problem: There is a theoretical and practice knowledge gap in regard to immediate loading of unsplinted implants in edentulous individuals. Objectives: This study aimed to: (1) determine the implant survival rate of 2 unsplinted implants supporting a mandibular complete overdenture following an immediate loading protocol, (2) assess marginal bone level and implant stability changes of these immediately loaded implants in a 4-month period and compared them to a control implant, and (3) describe the clinical complications associated with this mode of loading. Methods: In 18 edentate individuals (mean age 62±7 years), this phase-I trial with a pre/post design assessed the clinical outcomes following the immediate loading (<48 hours) of 2 unsplinted implants supporting a mandibular overdenture. Periapical radiograhs, bone probing measurements and resonance frequency analysis were used to assess marginal bone losses and implant stability changes of these two implants inserted in the mandibular parasymphyseal region, at baseline (T0) and 4-month follow-up (T1). A non-submerged and non-loaded implant inserted in the mandibular symphysis was used as a control. Data were analyzed using linear mixed models, adjusted Tukey tests, Friedman’s analysis of variance and Wilcoxon signed-ranks tests. Results: From T0 to T1, 3 immediately loaded implants failed in 2 patients. This resulted in an implant survival rate of 91.7% (33/36), and, per patient, of 88.9% (16/18). No control implant failed. The marginal bone losses around loaded implants were -0.2 ± 0.3 mm for radiographic measurements and -0.5 ± 0.6 mm for probing measurements. There was no statistically significant difference between immediately loaded and control implants in regard to the supporting marginal bone losses. The implant stability levels increased of 5 ISQ units regardless of loading. There was no statistically significant difference in the mean ISQ levels between immediately loaded and control implants at T0 or T1. Five out of 18 patients experienced no clinical complication, while 9 of them had at least two. Apart from implant failures, none of these clinical complications led to changes in the protocol. Conclusion: The short-term results suggest that: (1) the implant survival rate following the immediate protocol is similar to those reported during a conventional loading protocol, (2) marginal implant supporting bone and stability changes are not different compared to those of a control implant, (3) a high level of clinical and surgical experience is required to perform the procedures and to manage the associated complications. These preliminary results should be confirmed in a phase II clinical trial.
19

Les attentes, la satisfaction et la qualité de vie des édentés suite à une réhabilitation par mise en charge immédiate d'une prothèse totale reliée à deux implants non jumelés : une étude pilote expérimentale

Menassa, Melanie 05 1900 (has links)
Problématique : La majorité des études publiées sur la réhabilitation par mise en charge immédiate de deux implants non jumelés avec une prothèse totale mandibulaire de recouvrement n’ont rapporté que des mesures cliniques objectives et très peu ont évalué les mesures centrées sur le patient, et ce, avec des erreurs de mesure. Aucune étude n’a évalué les attentes des patients vis-à-vis d'un tel protocole. Objectifs : Évaluer les attentes, le niveau de satisfaction ainsi que la qualité de vie reliée à la santé bucco-dentaire des édentés complets suite à un protocole de mise en charge immédiate. Méthodologie : Cet essai clinique de phase 1 utilise un design pré-post afin d’évaluer les mesures centrées sur le patient. Dix-huit individus, complètement édentés et âgés en moyenne de 62,39 ± 7,65 ans, ont reçu une prothèse totale mandibulaire de recouvrement sur deux implants non jumelés suite à un protocole de mise en charge immédiate, conjointement à une prothèse totale conventionnelle maxillaire. Un instrument adapté pour mesurer leurs attentes à l’aide d’échelles visuelles analogues, le questionnaire « McGill Denture Satisfaction Instrument » ainsi que le questionnaire OHIP-20 ont été remis aux patients avant de procéder aux traitements (T0), ainsi qu’aux rendez-vous de suivi à 2 semaines (T1), 1 mois (T2) et 4 mois (T3). De plus, l’inventaire de personnalité révisé (NÉO PI-R) ainsi qu’un questionnaire sociodémographique ont été remplis par les participants. Les « change scores » ont été calculés puis des tests non paramétriques et des analyses de variances en mesures répétées suivies de comparaisons par paires ont été utilisés afin d’analyser les données recueillies. La taille d’effet a été estimée. Résultats : Les participants avaient différentes attentes par rapport à la mise en charge immédiate. Certains s’attendaient à un effet positif à court terme par rapport à leur apparence esthétique (83,3 %) et à leur vie sociale (55,7 %), alors que d’autres avaient des craintes envers leur confort (5,6 %), leur habileté à mastiquer (11,1 %) et à nettoyer leur prothèse inférieure (11,1 %). À 4 mois, le protocole de mise en charge immédiate avait rencontré la majorité des attentes des patients par rapport à l’esthétique (94.4 %), la mastication (83.3 %), la phonétique (61.1 %), le confort (94.4 %), l’hygiène (88.9 %) et leur vie sociale (88.9 %). Une amélioration statistiquement significative de la satisfaction en générale, du confort, de l’esthétique, de la stabilité de la prothèse inférieure et de l’habileté à mastiquer a été notée à 2 semaines (p<0,001). Également, les comparaisons par paires ont révélé une diminution statistiquement significative du score total de l’OHIP-20 (p < 0,001) de même que la majorité des domaines de l’OHIP (p < 0.01), sauf pour l’handicap social qui n’a diminué significativement qu’après 1 mois (p = 0.01). Ces changements (pour la satisfaction et la qualité de vie) sont restés stables au cours des suivis subséquents. Indépendamment des traits de personnalité et des variables sociodémographiques, le protocole immédiat a satisfait 94,4 % des participants et a amélioré leur qualité de vie avec une large magnitude d’effet (d = 1.9; p < 0.001). Bien que deux patients aient perdu des implants au cours du traitement, 100 % des participants étaient d’accord pour recommander cette procédure à leurs pairs. Conclusions: Le protocole de mise en charge immédiate semble satisfaire les patients quelles que soient leurs attentes. Le protocole MCI peut améliorer, à court terme, la qualité de vie des patients totalement édentés. Les résultats prometteurs de la phase 1 devraient être corroborés lors de la 2e phase de cette étude. / Statement of problem: Most published research on the immediate loading of a mandibular 2-implant overdenture has only reported on clinical outcomes. Few studies have evaluated patients centered-outcomes but with measurement errors. Consequently, there is a need to assess clinical and patient-reported outcomes in this regard. Objectives: To examine patients’ level of satisfaction, expectations and quality of life with regard to the implants’ immediate loading protocol in edentate individuals. Methods: This phase-I trial used a pre-post design to assess patient-centered outcomes in 18 edentate individuals (mean age 62.39 ± 7.65 years) who have received a 2-implant (unsplinted) mandibular overdenture through an immediate loading protocol. The McGill Denture Satisfaction Instrument, a VAS instrument assessing expectations and the OHIP-20 questionnaire were used to evaluate patients’ outcomes at baseline, 2 weeks, 1 and 4 months. Socio-demographic and personality trait data were obtained using the Revised NEO Personality Inventory and a self-administered questionnaire. Change scores were calculated and non-parametrical tests were used to analyse the data. Repeated measures ANOVAs and paired t-tests were also conducted, and effect size was estimated. Results: The participants had a wide range of expectations regarding the immediate loading protocol. Expectations included short-term positive impact on aesthetics (83.3 %) and social life (55.7 %). Other expectations included negative effects on comfort (5.6%), the ability to chew (11.1 %) and to clean their lower denture (11.1%). At 4 months, the immediate loading protocol had met most patients’ expectations regarding aesthetics (94.4%), the ability to chew (83.3%), ability to speak (61.1%), comfort (94.4%), the ability to clean their lower denture (88.9%) and their social life (88.9%). The statistical analysis showed an overall satisfaction increase with a median change score of 66 (range=7-98), 68 (range=7- 95), and 70 (range= 17- 99), at 2 weeks, 1 month and 4 months respectively. There was a statistically significant improvement in overall satisfaction, comfort, perceived aesthetics, stability of the overdenture, and ability to chew at 2 weeks (p < 0,001). Pairwise comparison (within-subjects comparisons) revealed significant decreases in total OHIP scores (P < 0.001), as well as fewer functional limitations, physical pain, psychological discomfort, physical disability, psychological disability, and handicap (P < 0.01) from baseline to 2 weeks, 1 month and 4 months follow-up. Social disability score decrease significantly only after 1 month follow-up (p = 0.01). These changes remained stable during subsequent follow-ups. The protocol satisfied 94.4% of the participants and improve their quality of life with an estimated effect size of 1.9 (p < 0.001), regardless of socio-demographic and personality profiles. There was 100% agreement among patients on recommending this procedure to their peers. Conclusions: Immediate loading of two unsplinted implants with a mandibular overdenture seemed to fulfill patients’ satisfaction regardless of their expectations and may improve oral health-related quality life of edentate individuals in short-term. Encouraging results from phase I should be confirmed and approved in Phase II clinical trials.
20

A randomized controlled trial evaluating the quality of life and the sense of coherence in seniors wearing complete conventional dentures or mandibular two-implant overdentures

Jabbour, Zaher 12 1900 (has links)
La supériorité des prothèses mandibulaires retenues par deux implants (IODs) sur les prothèses conventionnelles (CDs) nécessitent d’être éclaircies notamment en rapport à leur influence sur la qualité de vie reliée à la santé bucco-dentaire (OHRQoL) ainsi que sur la stabilité de cet effet de traitement. De plus, l’influence des facteurs psychologiques, tel que le sens de cohérence (SOC), sur l’effet de traitement reste encore inconnue. Le but de cette étude est de déterminer l’amplitude de l’influence du port des IODs et des CDs sur l’OHRQoL et d’évaluer la stabilité de l’effet de traitement dans le temps, tout en prenant en considération le niveau du SOC. MÉTHODOLOGIE: Des participants édentés (n=172, âge moyen 71, SD = 4.5) ayant reçu des CDs ou des IODs ont été suivis sur une période de deux ans. L’OHRQoL a été évaluée à l’aide du questionnaire « Oral Health Impact Profile (OHIP -20) » et ce avant le traitement et à chacun des deux suivis. Le SOC a été évalué à l’aide du questionnaire « The Orientation to Life (SOC -13) » à chacun des deux suivis. Des analyses statistiques ont été effectuées pour évaluer les différences intra et entre groupes (analyses statistiques descriptives, bivariées et multivariées). RÉSULTATS: Une amélioration statistiquement significative de l’OHRQoL entre les statuts avant et après traitement a été notée dans les deux groupes (Wilks’s Lambda = 0.473, F (1,151) = 157.31, p < 0.0001). L’amplitude de l’effet du traitement IOD est 1.5 fois plus grande que celle du traitement CD. Ces résultats ont été stables pendant les deux années d’étude et ils n’ont pas été influencés par le SOC. CONCLUSION: Le traitement IOD amène une meilleure OHRQoL à long terme en comparaison avec le traitement CD et ce sans influence du niveau du SOC. Ces résultats sont cliniquement significatifs et confirment la supériorité des IODs sur les CDs. / ABSTRACT The superiority and stability of the effect of mandibular two-implant retained overdentures (IODs) over conventional dentures (CDs) in relation to the oral health-related quality of life (OHRQoL) remain to be clarified. Furthermore, the influence of psychological factors, such as the sense of coherence (SOC), on the perception of treatment outcomes is still unknown. The aim of this study was to determine the magnitude of the effect of IODs and CDs on the OHRQoL and assess the stability of the treatment over time taking into account the level of SOC. METHODOLOGY: Edentulous participants (n = 172, mean age 71, SD = 4.5) wearing CDs or IODs were followed up for two years. The OHRQoL was assessed at baseline and both follow-ups using the « Oral Health Impact Profile (OHIP-20) » questionnaire. The SOC was only assessed at both follow-ups using « The Orientation to Life (SOC-13) » questionnaire. Statistical analyses were conducted to evaluate between and within treatment differences (descriptive, bivariate and multivariate statistical analyses). RESULTS: A significant pre-/post-treatment improvement in the OHRQoL for both treatment groups was found (Wilks’s Lambda = 0.473, F (1,151) = 157.31, p < 0.0001). The magnitude of the effect in the IOD group was 1.5 times larger than that in the CD group. These outcomes were stable over the two-year study period and the SOC did not influence any of these results. CONCLUSION: IODs provide better long-term OHRQoL than CDs regardless of SOC level. The results are clinically meaningful and confirm the superiority of IODs over CDs.

Page generated in 0.0733 seconds