• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • 11
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 1
  • Tagged with
  • 33
  • 33
  • 33
  • 10
  • 8
  • 8
  • 8
  • 8
  • 7
  • 7
  • 6
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Análise do suporte ventilatório mecânico durante anestesia e sua correlação com as complicações pulmonares pós-operatórias: um estudo observacional / Analysis of the mechanical ventilatory support in anesthesia and its correlation with the postoperative pulmonary complications: an observational study

Adriana Sayuri Hirota 23 March 2005 (has links)
Introdução: A formação de atelectasia durante a indução anestésica pode ser um dos fatores responsáveis pela ocorrência de complicações pulmonares pós-operatórias (CPP). A aplicação de pressão positiva expiratória ao final da expiração (PEEP), uso criterioso de altas frações inspiradas de oxigênio e a utilização de manobras de recrutamento alveolar no período intra-operatório são recursos utilizados para a prevenção de atelectasia em procedimentos anestésicos. O objetivo deste estudo foi avaliar o modelo de ventilação mecânica adotado em procedimentos anestésicos de longa duração e suas correlações com as complicações pulmonares pós-operatórias. Métodos: Foram avaliadas em estudo observacional as cirurgias com mais de cinco horas de duração. No início do procedimento anestésico, na sala de cirurgia e após o seu término, na unidade de terapia intensiva, os parâmetros ventilatórios utilizados foram anotados e correlacionados com os achados das radiografias torácicas e saturação periférica de oxigênio (SpO2) em ar ambiente. Resultados: Cento e vinte e um pacientes foram observados. O tempo total de anestesia 499,4 ± 159,8 minutos. O volume corrente (VC) determinado no período intraoperatório foi 8,09 ± 2,15 mL/kg e a PEEP utilizada de 3,05 ± 2,31 cmH2O. Houve diferença para a mediana da SpO2 em ar ambiente (96% [95-97] vs 95% [92-96], p <0,001) comparando os períodos pré e pós-operatório. A freqüência de pacientes que apresentaram atelectasia nas radiografias de tórax do período pós-operatório (38,8%) foi significantemente maior que a do período pré-operatório (0%), x2=32,259. Não foi encontrado correlação entre os achados e o tempo de anestesia (p=0,708); a PEEP intra-operatória (p=0,296); tempo de permanência com suporte ventilatório mecânico no pósoperatório (p = 0,146) e tabagismo (p = 0,563). Conclusões: No período intra-operatório o PEEP utilizado em procedimentos de longa duração é baixo. Ocorre queda na SpO2 e aumento na incidência de atelectasia no período pós-operatório em comparação com o pré-operatório. São necessários outros estudos para melhor avaliação dos fatores responsáveis / Introduction: The formation of the atelectasis during the induction of the anesthesia can be one of the factors involved in the occurrence of postoperative pulmonary complications (PPCs). The application of the positive end-expiratory pressure (PEEP), low inpiratory concentrations of oxygen and the alveolar recruitment maneuvers perform in the intraoperative period are approaches used in the prevention of atelectasis in the anesthesia procedures. The objective of this study was to evaluate, in prospective observational study, the pattern of mechanical ventilatory assistence during longer anesthesia procedures and its correlations with the PPCs. Methods: The surgeries procedures longer than five hours have been evaluated in observational study. At the beginning of the anesthesia procedure, in the operatory room and after its terminus, in the intensive care unit, the mechanical ventilation parameters were determined and correlated with the findings in the chest x-rays and peripheral oxygen saturation (SpO2) in room air. Results: One hundred twenty one patients have been observed. The total time of anesthesia was 499,4 ± 159,8 minutes. The tidal volume (VT) in the intraoperative period was 8,09 ± 2,15 mL/kg and the PEEP used was 3,05 ± 2,31 cmH2O. There was a difference for the median of the SpO2 in room air (96% [95-97] vs 95% [92-96], p <0,001) comparing the pre and postoperative periods. The frequency of patients who had presented atelectasis in the chest x-rays of the postoperative period (38,8%) was significantly higher than the preoperative period (0%), x2=32,259. No correlation was found among these findings and the anesthesia time (p=0,708); the intraoperative PEEP used (p=0,296); time with mechanical ventilatory support in the postoperative period (p = 0,146) and smoking habits (p = 0,563). Conclusions: In the intraoperative period, the PEEP is low in longer procedures. The SpO2 decreases and the incidence of the atelectasis increases in the postoperative period, when compared with the preoperative one. Other researches are required for better evaluation of the factors related for the development of the PPCs
32

Efeitos da pressão positiva continua nas vias aereas aplicada durantes a circulação extracorporea na troca gasosa pulmonar no pos-operatorio de cirurgia de revascularização miocardica / Effects of continous positive airway pressure applied during cardiopulmonary bypass on pos-operative pulmonary gas exchange in coronary artery bypass grafting

Figueiredo, Luciana Castilho de 11 April 2008 (has links)
Orientador: Sebastião Araujo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-12T08:30:37Z (GMT). No. of bitstreams: 1 Figueiredo_LucianaCastilhode_D.pdf: 2533700 bytes, checksum: 33bede305be3c550ada42648ae70b2f1 (MD5) Previous issue date: 2008 / ResumoObjetivo: Comparar os índices de trocas gasosas no pós-operatório de pacientes submetidos à revascularização do miocárdio (RM) que receberam ou não pressão positiva contínua nas vias aéreas (CPAP) durante a circulação extracorpórea (CEC). Método: Trinta pacientes adultos submetidos à RM com CEC no período de março a setembro de 2005 foram alocados aleatoriamente em dois grupos: CPAP (n=15), pacientes que utilizaram CPAP a 10 cmH2O durante a CEC, e controle (n=15), pacientes que não utilizaram CPAP. Foram analisados a PaO2/FiO2 e o P(A-a)O2 em quatro momentos: Pré (logo antes da CEC, com FiO2 = 1,0); Pós (30min pós-CEC, com FiO2 = 1,0); PO imediato (12h após a cirurgia, com FiO2 = 0,4 utilizando máscara facial) e 1º PO (24 horas após a cirurgia, com FiO2 = 0,5 utilizando máscara facial). Resultados: A PaO2/FiO2 e o P(A-a)O2 mostraram uma piora significativa no decorrer do tempo dentro de cada grupo, porém sem diferenças significativas entre os grupos em nenhum momento. Quando a PaO2/FiO2 foi subdividida em três categorias, foi observada uma maior prevalência de pacientes do grupo CPAP com valores acima de 200mmHg (p=0,02) apenas no momento Pós (30min pós-CEC). Conclusão: O uso de CPAP de 10cmH2O durante a CEC, muito embora tenha resultado em melhores valores na PaO2/FiO2 30 minutos pós-CEC, não resultou em benefícios duradouros nas trocas gasosas durante o PO. Concluiu-se que, em pacientes submetidos à RM, a aplicação de CPAP 10cmH2O não melhora significativamente as trocas gasosas pulmonares no pós-operatório. / Abstract: Objective: To compare postoperative (PO) pulmonary gas exchange indexes in patients submitted to myocardial revascularization (MR) with or without the application of continuous positive airway pressure (CPAP) during cardiopulmonary bypass (CPB). Methods: Thirty adult patients submitted to MR with CPB between March and September 2005 were randomly allocated to two groups: CPAP (n=15), patients that received CPAP at 10 cmH2O during CPB, and control (n=15), patients that didn't receive CPAP. PaO2/FiO2 and P(A-a)O2 were analyzed at four moments: Pre (just before CPB, with FiO2 = 1.0 ); Post (30min post-CPB, with FiO2 = 1.0); immediate PO period (12h post-surgery, with FiO2 = 0.4 by a facial mask) and first PO day (24h post-surgery, with FiO2 = 0.5 by a facial mask). Results: PaO2/FiO2 and P(A-a)O2 tend to get significantly worst as time elapsed during the postoperative period in both groups, but no differences were observed between them at any moment. When PaO2/FiO2 was subdivided into three categories, a greater prevalence of patients with values greater than 200 mmHg were observed in CPAP group only at moment Post (30min post-CPB; p = 0.02). Conclusion: CPAP at 10 cmH2O administered during CPB, although had lightly improved PaO2/FiO2 at 30 minutes post-CPB, had no significant sustained effect on postoperative pulmonary gas exchange. It was concluded that in patients submitted to MR, application of 10 cmH2O CPAP does not improve postoperative pulmonary gas exchange. / Doutorado / Pesquisa Experimental / Doutor em Cirurgia
33

Estudo do comportamento hemodinâmico, da troca gasosa, da mecânica respiratória e da análise do muco brônquico na aplicação de técnicas de remoção de secreção brônquica em pacientes sob ventilação mecânica / Airway clearance techniques in patients submitted to mechanical ventilation: A hemodynamic, gas exchange, respiratory mechanics and bronquial sputum study

Marcus Vinicius Herbst Rodrigues 11 December 2007 (has links)
INTRODUÇÃO: A aspiração traqueal (ASP) é um procedimento de rotina em pacientes sob ventilação mecânica, porém em algumas situações pode não ser eficiente. Como adjuvante usa-se a técnica \"Bag-Squeezing\" (BS) que consiste na hiperinflação manual associada à compressão torácica manual expiratória seguida ASP. Embora efetiva esta técnica pode apresentar algumas limitações como a desconexão do ventilador mecânico, além do controle precário do pico de pressão inspiratória (PPI) e pico de fluxo inspiratório (PFI). Como opção, podemos substituir o ressuscitador manual pelo próprio ventilador mecânico, alterando seus parâmetros e evitando assim a desconexão. Propusemos padronizar esta técnica e denominá-la PEEP-ZEEP (PZ); realizando-se a inflação dos pulmões aumentando a PEEP em 10 cmH2O, por 5 ciclos respiratórios, seguido de rápida descompressão pulmonar pela redução abrupta da PEEP até 0 cmH20, simultâneo à compressão torácica manual. OBJETIVOS: Avaliar o comportamento hemodinâmico, da troca gasosa e da mecânica respiratória, na aplicação das técnicas ASP, BS e PZ e seus efeitos na remoção de secreções brônquicas em pacientes ventilados mecanicamente. MÉTODO: 1ª etapa - \"Pacientes sem secreção brônquica\" estudamos prospectivamente 45 pacientes, divididos aleatoriamente em 3 grupos iguais, avaliamos os efeitos da aplicação das técnicas ASP, BS e PZ nos parâmetros hemodinâmicos, na troca gasosa e na mecânica pulmonar antes, imediatamente após, do 1o ao 10o e 30o min. subseqüentemente à aplicação das técnicas. Na 2ª etapa - \"Pacientes com hipersecreção brônquica\" foram estudados prospectivamente 15 pacientes ventilados mecanicamente, que apresentavam hipersecreção brônquica submetidos às técnicas ASP, BS e PZ aleatoriamente em intervalos de 2 horas, avaliamos as mesmas variáveis da 1a etapa porém acompanhamos os pacientes até 120 min. após cada intervenção. Avaliamos também o peso úmido da secreção brônquica, bem como sua reologia. RESULTADOS: 1ª etapa - Semelhantes quanto aos dados antropométricos e tempos de CEC, nossos pacientes apresentavam 59±10anos, IMC 26±3,2 kg/m2 e tempo médio de CEC de 91±19min. Houve elevação da FC somente após aplicação de BS (98±8; 106±10). PAM e SpO2 não se alteraram, observamos elevação na ETCO2 (36±6; 37±6 e 37±7; 39±8) nas técnicas BS e PZ respectivamente. Não verificamos alteração na mecânica respiratória até 30 min. após aplicação das técnicas. Durante a execução das técnicas BS e PZ respectivamente observamos elevação significante do PPI (63±17 vs 17±3), PPLATÔ (22±5 vs 26±3), PFI (154±27 vs 20±5) e PFE (86±20 vs 64±10). 2ª etapa - Nossos pacientes apresentavam 66±14anos, IMC 24±3,2 kg/m2 e tempo médio de CEC de 113±54min. A FC e a SpO2 não se alteraram, porém houve elevação significante da PAM imediatamente após a aplicação de ASP, BS e PZ (85±12 vs 101±16, 90±12 vs 100±14, 84±10 vs 97±11). Na PZ houve diminuição na ETCO2 (36±6 vs 35±7). Não observamos alteração na mecânica respiratória até 120 min. após aplicação das técnicas. Durante a execução das técnicas BS e PZ respectivamente observamos elevação significante do PPI (45±22 vs 27±3) e PFI (91±21 vs 44±17), porém a PPLATÔ (27±15 vs 26±3) e o PFE (71±20 vs 64±13) foram semelhantes entre elas. Não encontramos diferença significante no peso úmido do muco ASP(0,91±1), BS(1,09±1) e PZ(0,53±0,5), nem na análise do deslocamento e da viscoelasticidade. CONCLUSÕES: As técnicas não alteraram significantemente o comportamento hemodinâmico, de troca gasosa e de mecânica respiratória. BS e PZ foram capazes de aumentar o PFE, porém a nova proposta PZ permite maior controle das variáveis de mecânica respiratória, possibilitando monitoramento das pressões e fluxos impostos ao sistema respiratório. Todas as técnicas foram capazes de remover secreções brônquicas de forma semelhante. / INTRODUCTION: Tracheal suction (TS) is a routine procedure in patients submitted to mechanical ventilation. In association, the bag-squeezing (BS) technique is described as a manual hyperinflation associated to a manually assisted coughing followed by TS. This technique might present few limitations as its mechanical ventilator disconnection and poor control of variables such as peak inspiratory pressure (PIP) and peak inspiratory flow (PIF). We might substitute the manual ressuscitator by the mechanical ventilator itself altering its parameters and avoiding its disconnection. We proposed to standardize this technique and named it PEEP-ZEEP (PZ); inflate the lungs increasing the PEEP in 10 cmH20, trough 5 respiratory cycles, followed by an abrupt pulmonary decompression bringing the PEEP to 0 cmH20, associated to the manually assisted coughing. OBJECTIVES: Assess the hemodynamic, gas exchange and respiratory mechanics variables during the use of TS, BS and PZ techniques and assess their effects in the removal of bronchial secretions in mechanically ventilated patients. METHODS: First step - \"Patients without bronchial secretions\" - We assessed 45 patients prospectively, divided randomically into three groups, evaluating the effects of TS, BS and PZ techniques in the haemodynamics, gas exchange and respiratory mechanics variables before, immediately after, in the 10th and 30th minute after the technique. Second step - \"Patients with bronchial secretions\" - We assessed 15 mechanically ventilated patients submitted to the TS, BS and PZ techniques within 2 hours, evaluating the same variables of the first step. However we followed-up the patients until 120 minutes in each technique. We also assessed the humid weight of the bronchial secretions as well as the mucus reology. RESULTS: Results were similar when related to antropometric data and ECC period. First step - There was a raise in the HR after the BS procedure (98±8; 106±10), MAP and SpO2 did not altered. Raise in ETCO2 (36±6; 37±6 and 37±7; 39±8) in the BS e PZ techniques respectively, without alteration in the respiratory mechanics until 30 minutes after the techniques. During the BS e PZ techniques, we observed a significant increase in PIP (63±17 vs 17±3), PPLATEU (22±5 vs 26±3), PIF (154±27 vs 20±5) and PEF (86±20 vs 64±10). Second step - HR and SpO2 did not altered, there was a significant increase in MAP immediately after the TS, BS and PZ techniques (85±12 vs 101±16, 90±12 vs 100±14, 84±10 vs 97±11). The PZ technique had lower ETCO2 (36±6 vs 35±7). We did not observed any respiratory mechanics alteration until 120 minutes after the techniques. During the BS e PZ techniques, respectively, we observed an increase in the PIP (45±22 vs 27±3) and PIF (91±21 vs 44±17), however the PPLATEU (27±15 vs 26±3) and PEF (71±20 vs 64±13) were similar. The PZ technique (0,54±0,5) remove less humid weight mucus when compared to TS (0,91±1) and BS (1,09±1), but the analysis by simulated cough machine PZ (25?11) was better then TS(33?13). CONCLUSION: All techniques remove bronchial secretions and did not altered the hemodynamic, gas exchange and respiratory mechanics significantly. BS and PZ were able to enhance the PEF, however the new proposition of the PZ technique allows a better control of the respiratory mechanics variables.

Page generated in 0.0811 seconds