• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 15
  • Tagged with
  • 15
  • 15
  • 12
  • 9
  • 7
  • 7
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação de ateromatose subclínica em pacientes HIV/aids: determinação da velocidade de onda de pulso e da espessura média-íntima de carótidas / Evaluation of subclinical atheromatous disease in HIV/AIDS patients: assessment of pulse wave velocity (PWV) and carotid intimamedia thickness (IMT)

Margareth da Eira 28 January 2010 (has links)
A terapia anti-retroviral altamente potente (HAART), determinou uma melhora significativa do prognóstico dos pacientes vivendo com HIV/aids. Contudo, a presença de toxicidades agudas e crônicas, incluindo risco aumentado de doenças cardiovasculares, acarretou novas implicações para a qualidade e expectativa de vida destes pacientes. O objetivo deste estudo foi determinar o risco cardiovascular de pacientes HIV/aids tratados e nãotratados com esquema HAART. De 02/2008 a 07/2009 foram incluídos 118 indivíduos entre 18 e 70 anos, procedentes do Instituto de Infectologia Emílio Ribas e do Hospital Universitário da USP, além de voluntários saudáveis. Os indivíduos foram distribuídos em 4 grupos: (1) pacientes com infecção pelo HIV em uso de HAART; (2) pacientes com infecção pelo HIV sem tratamento (naïve); (3) pacientes diabéticos não insulino-dependentes (DM); (4) controle. Foram avaliados em todos os participantes: parâmetros bioquímicos, teste de tolerância oral à glicose, PCR ultra-sensível, microalbuminúria, sorologias para hepatite B e hepatite C, ECG, EMI, VOP, escore de risco de Framingham (ERF) e presença de síndrome metabólica (SM). Os pacientes DM tinham idade mais avançada (51,7 ± 9,7 anos) e 75, 8% eram do sexo feminino. Os dados foram ajustados para a idade (média ± erro-padrão). A relação cintura-quadril foi maior no grupo HAART que no controle (0,94 ± 0,01 vs. 0,88 ± 0,01, p< 0,0001); a pressão arterial sistólica média aferida no dia da visita foi maior no grupo HAART comparado ao grupo naive e controle (124,7 ± 2,3 vs. 118,1 ± 2,4 vs. 119,8 ± 2,2 mmHg, respectivamente; p= 0,001 e p= 0,005), e a pressão arterial diastólica média foi maior no grupo HAART que no naive (78,2 ± 1,8 vs. 75,9 ± 1,9 mmHg, respectivamente; p= 0,03); os níveis séricos de triglicérides estavam mais elevados no grupo HAART comparado aos grupos naive e controle (233,7 ± 193,4 vs. 137,3 ± 108,6 vs. 147,2 ± 87,3 mg/dL, respectivamente; p= 0,03 e p=0,04); microalbuminúria foi maior no grupo HAART que nos grupos naive e DM (86,2 ± 27,3 vs. 49,8 ± 30,5 vs. 30,8 ± 30,6 mg/dL, respectivamente; p= 0,01 e p= 0,009). A EMI da carótida direita foi maior no grupo naive comparado aos grupos HAART e controle (0,55 ± 0,02 vs. 0,52 ± 0,02 vs. 0,52 ± 0,02 mm, respectivamente; p< 0,0001), enquanto a EMI da carótida esquerda foi maior no grupo HAART comparado aos grupos naive e DM (0,64 ± 0,04 vs. 0,53 ± 0,04 vs. 0,52 ± 0,04, respectivamente; p< 0,0001). Houve diferença significativa em relação à VOP entre os grupos HAART e controle (9,7 ± 1,8 vs 8,7 ± 0,03 m/seg, p = 0,03). SM foi mais freqüente no grupo HAART que nos grupos naive e controle (41,4% vs. 25,0% vs. 28,1%, p= 0,0001). O ERF evidenciou risco alto em 27,6% dos pacientes do grupo HAART, o que foi significativo em relação aos grupos naive e controle (p=0,003). O nadir de CD4 foi menor nos pacientes do grupo HAART comparado ao grupo naive (208 ± 191 vs. 449 ± 176 células/L, p< 0,0001). A carga viral atual foi maior no grupo naive que no grupo HAART (13.633 ± 25.314 vs. 76 ± 61 cópias/ml, p= 0,005). Este estudo demonstra que pacientes com infecção pelo HIV em uso de HAART apresentam maior risco cardiovascular em relação aos pacientes não-tratados, evidenciado pela presença de maior freqüência de SM, maior ERF, maior rigidez arterial e presença de aterosclerose prematura mensurada pelo EMI da carótida esquerda. Isto ocorreu mesmo na ausência de viremia detectável, o que significa que devemos ter atenção para o risco de aterosclerose subclinica no seguimento de pacientes HIV/aids sob adequado tratamento antiretroviral, inclusive com eficaz controle imunológico e virológico. / The highly active antiretroviral therapy (HAART), led to a significant improvement in the prognosis of patients living with HIV/AIDS. However, the presence of acute and chronic toxicities, including increased risk of cardiovascular disease, yielded further implications for the quality and life expectancy of these patients. The aim of this study was to determine the cardiovascular risk of HIV/AIDS patients treated and untreated with HAART. From february/2008 to july/2009 we enrolled 118 subjects between 18 and 70 years, attending at the Institute of Infectious Diseases Emilio Ribas and the University Hospital from USP, as well as healthy volunteers. The subjects were divided into 4 groups: (1) patients with HIV-infection on HAART; (2) patients with untreated HIV-infection (ART-naive); (3) diabetic patients not insulin-dependent (DM); (4) controls. Were evaluated in all participants: biochemical parameters, oral glucose tolerance test, high-sensitivity Creactive protein, microalbuminuria, serologies for hepatitis B and hepatitis C, ECG, carotid IMT, PWV, Framingham risk score (FRE) and the presence of metabolic syndrome (MS). The DM patients were older (51.7 ± 9.7 years) and 75.8% were female. The data were adjusted for age (mean ± standard error). The waist-to-hip ratio was higher in the HAART-treated patients than in the controls (0.94 ± 0.01 vs. 0.88 ± 0.01, p< 0.0001), the mean systolic blood pressure measured on the day of the visit was higher in the HAARTtreated patients compared to the ART-naive and controls (124.7 ± 2.3 vs. 118.1 ± 2.4 vs. 119.8 ± 2.2 mmHg, respectively, p= 0.001 and p= 0.005), and the mean diastolic blood pressure was higher in the HAART-treated patients than in the ART-naive (78.2 ± 1.8 vs. 75.9 ± 1.9 mmHg, respectively, p= 0.03); serum triglycerides were higher in the HAART-treated patients compared to the ART-naive subjects and controls (233.7 ± 193.4 vs. 137.3 ± 108.6 vs. 147.2 ± 87.3 mg/dL, respectively, p= 0.03 and p= 0.04); microalbuminuria was higher in the HAART-treated patients than in the ARTnaive and DM (86.2 ± 27.3 vs. 49.8 ± 30.5 vs. 30.8 ± 30.6 mg/dL, respectively, p=0.01 and p=0.009). The right carotid IMT was increased in the ART-naive compared to HAART-treated patients and controls (0.55 ± 0.02 vs. 0.52 ± 0.02 vs. 0.52 ± 0.02 mm, respectively, p< 0.0001), while the left carotid IMT was increased in the HAART-treated patients compared to the ART-naive and DM (0.64 ± 0.04 vs. 0.53 ± 0.04 vs. 0.52 ± 0.04, respectively, p< 0.0001). There was significant difference in PWV between the HAART-treated patients and controls (9.7 ± 1.8 vs. 8.7 ± 0.03 m/s, p= 0.03). MS was more prevalent in the HAART-treated patients than in the ART-naive and controls (41.4% vs. 25.0% vs. 28.1%, p= 0.0001). The FRE showed high risk in 27.6% of HAART-treated patients, which was significant compared to ART-naive and controls (p= 0.003). The nadir CD4 count was lower in HAART-treated patients compared to the ART-naive (208 ± 191 vs. 449 ± 176 cells/L, p<0.0001). Current viral load was higher in the ART-naive than in the HAART-treated patients (13,633 ± 25,314 vs. 76 ± 61 copies/ml, p= 0.005). This study shows that patients with HIV infection receiving HAART have a higher cardiovascular risk compared to untreated patients, as evidenced by the presence of a higher frequency of MS, higher ERF, increased arterial stiffness and the presence of early atherosclerosis measured by left carotid IMT. These abnormalities occurred even in the absence of detectable viremia, which means that physicians must pay attention to the risk of subclinical atherosclerosis as a result of HIV-infected patients under appropriate antiretroviral treatment, including effective virological and immunological control.
12

Efeitos da atividade física aeróbica sobre a pressão arterial sistêmica e rigidez arterial em pacientes submetidos a transplante cardíaco / Effects of aerobic physical activity on blood pressure and arterial stiffness in patients undergoing cardiac transplantation

Lucas Nóbilo Pascoalino 19 October 2012 (has links)
O transplante cardíaco permanece sendo o procedimento de escolha para a insuficiência cardíaca refratária, apresentando resultados favoráveis em termos da sintomatologia, qualidade de vida e sobrevida desses pacientes. A hipertensão arterial sistêmica aparece como a comorbidade de maior incidência neste grupo de pacientes, chegando a 95% após cinco anos. O efeito do exercício físico sobre a dinâmica do comportamento tensional na monitorização da pressão arterial ambulatorial durante 24 horas (MAPA-24h) e da rigidez arterial não tem sido estudado neste grupo de pacientes. Nós avaliamos os efeitos da atividade física aeróbia sobre a dinâmica do comportamento tensional na MAPA-24h, rigidez arterial e as variáveis cardiovasculares em indivíduos após um ano de transplante cardíaco. Trinta e nove pacientes de ambos os sexos, randomizados para grupo treino (GT) (n = 29; 45 ± 13 anos) ou grupo controle (GC) (n = 9; 51 ± 11 anos) realizaram, antes e após o período de 12 semanas de seguimento, exames de MAPA-24h, velocidade de onda de pulso carótido-femoral (VOP) e teste de esforço cardiopulmonar, com coletas de amostras sangüíneas para dosagem de norepinefrina (Nor) (repouso e pico). Treinamento físico aeróbio foi realizado três vezes por semana, sendo duas supervisionadas e uma não supervisionada, durante 40 minutos inicialmente com a frequência cardíaca monitorada em 80% do ponto de compensação respiratória. O GT apresentou redução significativa da pressão arterial sistólica nos períodos da média das 24 horas (de 120 ± 11 para 116 ± 14mmHg, p<0,05) e vigília (de 123 ± 11 para 118 ± 13mmHg, p<0,05). A pressão arterial diastólica apresentou redução significativa para os três períodos sendo na média das 24 horas (de 81 ± 9 para 74 ± 9mmHg, p< 0,001), vigília (de 83 ± 9 para 75 ± 10mmHg, p<0,001) e noturno ( de 77 ± 10 para 71 ± 10mmHg, p<0,001). A VOP não apresentou redução significativa após o período de seguimento para ambos os grupos; GT (de 10,0 ± 1,9 para 9,7 ±1,9m/s, p = ns) e GC (de 10,3 ± 2,2 para 10,4 ± 2,8m/s, p = ns), porém os níveis da Nor tiveram aumento significativo no pico do exercício no grupo GT (de 2386 ± 1274 para 3292 ± 1410 pg/ml p<0,01) e também em relação ao grupo GC pós seguimento (3292 ± 1419 versus 2178 ± 659 pg/ml, p<0,05). O treinamento físico aeróbio reduziu a pressão arterial sistólica/diastólica em 4,7/7,5 mmHg durante a vigília e em 3,5/5,8 mmHg durante o sono após TX, além de melhorar o condicionamento cardiorrespiratório com aumento do VO2pico, FCmáx e do tempo de exercício. / Cardiac transplantation remains the procedure of choice for refractory heart failure, with favorable results in terms of symptoms, quality of life and patient survival. Hypertension appears as a higher incidence of comorbidity in this group of patients, reaching 95% after five years. However, the effect of exercise training in the behavior of 24-hour ambulatory blood pressure monitoring (ABPM) and arterial stiffness has not been studied in this group of patients. We assessment the effects of aerobic physical activity in the behavior of ABPM, arterial stiffness and cardiovascular variables in patients being heart transplanted for a year or more. Thirty-nine patients of both genders were evaluated, then randomized to either training group (TG) (n = 29, 45 ± 13 years) or control group (CG) (n = 9, 51 ± 11 years) and reevaluated after 12 weeks of follow-up. Pre and post evaluations combined examinations of ABPM, carotidfemoral pulse wave velocity (PWV) and graded exercise test, with collections of blood samples for measurement of norepinephrine (Nor) (rest and peak). Aerobic exercise was performed in the TG three times-a-week, two supervised and one unsupervised for 40 minutes initially at an intensity of 80% of heart rate achieved at the respiratory compensation point. The TG showed a significant reduction in systolic blood pressure during average of 24 hours (from 120 ± 11 to 116 ± 14mmHg, p < 0.05) and diurnal cycle (from 123 ± 11 to 118 ± 13mmHg, p<0.05). Diastolic blood pressure decreased significantly for the three periods, the average of 24 hours (from 81 ± 9 to 74 ± 9mmHg, p<0.001), diurnal cycle (from 83 ± 9 to 75 ± 10mmHg, p < 0.001) and nighttime (from 77 ± 10 to 71 ± 10mmHg, p < 0.001). The PWV showed no significant reduction after the followup period for both groups; TG ( from 10.0 ± 1.9 to 9.7 ± 1.9m/s, p = ns) and CG (from10.3 ± 2.2 to 10.4 ± 2.8m/s, p = ns) and the levels of the Nor had a significantly higher peak exercise in TG (from 2386 ± 1274 to 3292 ± 1410 pg/ml p <0.01) and also in relation to the control group after follow-up (3292 ± 1419 versus 2178 ± 659 pg / ml, p <0.05). The exercise training reduced both systolic and diastolic blood pressure in 4.7 and in 7.5 mmHg during daytime, respectively. Reduction also happened during nighttime in 3.5 and in 5.8 mmHg for these variables, respectively. Exercise training improved VO2peak, HRmax and time of exercise (cardiorespiratory fitness) after follow-up, as well.
13

[en] HIGH SENSITIVITY TRANSDUCERS FOR MEASURING ARTERIAL PULSE WAVE VELOCITY, BASED ON IMPEDANCE PHASE READINGS OF GMI SENSORS / [pt] TRANSDUTORES DE ALTA SENSIBILIDADE DESTINADOS À MEDIÇÃO DA VELOCIDADE DA ONDA DE PULSO ARTERIAL, BASEADOS NA LEITURA DA FASE DA IMPEDÂNCIA DE SENSORES GMI

LIZETH STEFANÍA BENAVIDES CABRERA 16 November 2021 (has links)
[pt] A velocidade da onda de pulso (VOP) tem sido identificada como o padrão-ouro para avaliação da rigidez arterial e, recentemente, vem sendo reconhecida como um importante indicador no diagnóstico e tratamento de doenças cardiovasculares. Atualmente, já existem dispositivos comerciais capazes de efetuar a medição da VOP, entretanto, ainda exigem um investimento financeiro significativo e alguns requerem um treinamento especializado para seu correto uso. Os, transdutores de pressão atuais são majoritariamente baseados em sensores piezoresistivos, piezoelétricos e capacitivos. Entretanto, pesquisas recentes demostraram que transdutores de pressão que utilizam sensores magnéticos baseados na magnetoimpedância gigante (GMI) apresentam elevada sensibilidade. Tendo em vista que a VOP é um importante indicador do risco de distúrbios cardiovasculares, e considerando os potenciais beneficios dos sensores GMI em relação às demais alternativas, esta tese de doutorado buscou utilizar-se destes elementos sensores a fim de desenvolver um sistema de medição portátil, não-invasivo, de baixo custo, acessível e simples de usar, capaz de efetuar a medição da VOP. Neste intuito, foram desenvolvidos transdutores de alta sensibilidade, baseados nas características de fase da impedância de sensores de Magnetoimpedância Gigante, destinados à medição da velocidade da onda de pulso arterial. A fim de se otimizar as características de desempenho dos transdutores, foram realizadas avaliações teórico-computacionais dos transdutores na configuração em malha aberta e fechada, bem como ensaios experimentais dos protótipos projetados. As caracterizações e ensaios experimentais realizados com o transdutor de pressão em malha aberta resultaram em uma sensibilidade de 59,6 mV/kPa, e resolução de 192,8 Pa para uma média de 30 amostras, na banda de passagem de 1000 Hz. Por outro lado, a configuração em malha fechada apresentou uma sensibilidade de 54,2 mV/kPa, e resolução de 206,0 Pa para uma média de 30 amostras, na banda de passagem de 32 Hz. Tendo em vista os valores de sensibilidade e resolução obtidos, propõe-se empregar o sistema de transdução de pressão que incorpora uma câmara incompressível para amplificação mecânica, na medição de ondas de pulso arterial. Neste protótipo, uma pequena membrana semirrígida localizada na superfície da câmara incompressível é posicionada sobre a superfície da pele, próxima à artéria de interesse. Deste modo, pequenas mudanças de pressão na superfície da pele, causadas pela onda de pulso arterial, provocam uma variação do campo magnético sobre o elemento sensor. Por outra parte, devido à alta sensibilidade apresentada pelo transdutor magnetico (magnetômetro GMI) na configuração de malha aberta (0,2 mV/nT) e de malha fechada (0,19 mV/nT), estes foram usados para medir diretamente a forma de onda do pulso arterial, sem utilizar uma câmara incompressível para transdução mecânica. Nesta medição, considerando a adequada resolução espacial para as demandas anatômicas, utiliza-se um pequeno marcador magnético, envolto por uma fita adesiva hipoalergênica e flexível, aderida á região da pele sobre a artéria de interesse, e aproxima-se o sensor magnético GMI da superfície da pele onde o marcador foi colocado. Finalmente, as configurações propostas foram analisadas e comparadas, a fim de se identificar aquela com melhor desempenho, a qual foi utilizada para medição da VOP. Como o estudo envolve o registro da onda de pulso em participantes da pesquisa, o projeto foi submetido à apreciação e aprovado pela Comissão da Câmara de Ética em Pesquisa da Pontifícia Universidade Católica do Rio de Janeiro (PUC-Rio) 045/2020 – Protocolo 83/2020. Espera-se que o dispositivo desenvolvido contribua para o avanço tecnológico do ferramental utilizado no setor da saúde. / [en] Pulse wave velocity (PWV) is considered the gold standard for assessing arterial stiffness and recently, it has been recognized as an important indicator in the diagnosis and treatment of cardiovascular disease. Currently, there are commercial devices capable of measuring PWV, however, significant investments are required and some devices requires specialized training for their correct use. Conventional pressure-sensing devices are mainly based on piezoresistive, piezoelectric and capacitive sensors. Recent investigations, however, show that pressure transducer using magnetic sensors based on the giant Magnetoimpedance (GMI) present high-sensitivity. Considering that, PWV is a significant risk factor for future cardiovascular disease and in view of some of the advantages of GMI sensors in relation to another sensing technologies, this doctoral thesis aims to develop a portable measurement system, non-invasive, low-cost, accessible and simple to use, capable of measuring PWV. For this purpose, we have developed a high-sensitivity transducers based on the impedance phase characteristics of GMI sensors, for measuring the arterial pulse wave velocity. In order to improve the performance characteristics of the transducers, computational and theoretical analysis in open and closed loop configuration were performed. The characterizations and experimental tests performed with the open-loop pressure transducer resulted in a sensitivity of 59.6 mV/kPa, and resolution of 192.8 Pa for an average of 30 samples, in the 1000 Hz passband. On the other hand, the closed-loop configuration presented a sensitivity of 54.2 mV/kPa, and a resolution of 206.0 Pa for an average of 30 samples, in the 32 Hz passband. In view of the considerable sensitivity and resolution obtained, it is proposed to employ a pressure transduction system that incorporates an incompressible chamber for mechanical amplification, in the measurement of arterial pulse waves. In this prototype, a small semi-rigid membrane located on the surface of the incompressible chamber is positioned over the surface of the skin, close to the artery of interest. In this way, small pressure changes on the skin surface, caused by the arterial pulse wave, cause a variation of the magnetic field on the sensing element. On the other hand, due to the high sensitivity presented by the magnetic transducer (GMI magnetometer) in the open-loop (0.2 mV/nT) and closed-loop (0.19 mV/nT) configurations, they were used to measure the shape pulse waveform without using an incompressible chamber for mechanical transduction. In this test, considering the adequate spatial resolution for the anatomical demands, a small magnetic marker is used, the magnetic marker is attached to the skin region over the artery of interest, and the GMI magnetic sensor is approached near the marker placed of the skin surface. Finally, the proposed configurations were analyzed and compared in order to identify the one with the best performance, which was used to measure PWV. As the study involves recording the pulse wave in research participants, the project was submitted for consideration and approved by the Research Ethics Committee of the Pontifical Catholic University of Rio de Janeiro (PUC-Rio) 045/2020 – Protocol 83/2020. It is expected that the device developed will contribute to the technological advancement of the tools used in the health sector.
14

Estudo da relação entre peso de nascimento, crescimento e aterosclerose subclínica em adultos do Centro de Saúde-Escola \"Prof. Samuel B. Pessoa\" da Faculdade de Medicina da Universidade de São Paulo / Study on the relationship between birth weight, growth, and subclinical atherosclerosis in adults at \"Prof. Samuel B. Pessoa\" Health Center-School from the Medical School of the University of São Paulo

Valente, Maria Helena 12 September 2013 (has links)
JUSTIFICATIVA E OBJETIVOS: Condições adversas no ambiente pré-natal e primeiros anos de vida são independentemente associados com risco aumentado de doença cardiovascular. A hipótese aceita atualmente para essa associação é a de que agravos, principalmente nutricionais, ocorridos durante a gestação alteram a organização de órgãos e sistemas, que ao serem solicitados na vida adulta, teriam menor capacidade funcional. Com base nessa premissa, o trabalho tem o objetivo de estudar a relação entre o peso ao nascer, crescimento no primeiro ano de vida e fatores de risco para doença cardiovascular e aterosclerose subclínica em adultos do Centro de Saúde-Escola (CSE) \"Prof. Samuel B. Pessoa\" da Faculdade de Medicina da Universidade de São Paulo. MÉTODOS: Em 2009, 88 adultos jovens com idade entre 20-31 anos, seguidos desde o início da vida no CSE, foram submetidos ao diagnóstico de aterosclerose subclínica. Informações relacionadas às características sociodemográficas, dados antropométricos, medidas da pressão arterial, perfil metabólico, e avaliação da aterosclerose subclínica pela ultrassonografia e métodos gráficos foram obtidas dos adultos, e estudadas de acordo com 2 pontos de corte em relação ao peso de nascimento (< 2.500 gramas; e, > 3.500 gramas) e ganho de peso no primeiro ano de vida. Os pesos foram obtidos dos registros de prontuários. Os achados atuais dos adultos foram analisados em relação às condições de nascimento e ao ganho de peso no primeiro ano de vida. Para realização das análises estatísticas foram realizadas regressões multivariadas. RESULTADOS: Baixo peso ao nascer, menor de 2.500 gramas (g) foi negativamente correlacionado com a relação cintura-quadril (RCQ) elevada, segundo coeficiente de regressão (CR) igual a -0,323, IC 95% [-0,571, -0,075] p < 0,05, níveis de pressão arterial diastólica (CR=-4,744, IC 95% [-9,017,-0,470] p < 0,05), HDL-colesterol reduzido (CR=-0,272, IC 95% [-0,516, -0,029] p < 0,05), e frequência da espessura da média-íntima (EMI) média da carótida esquerda (CE) acima do p75 (CR=-0,242, IC 95% [-0,476,-0,008] p < 0,05). Peso ao nascer maior do que 3.500 g foi positivamente associado com IMC (CR=2,832, IC 95% [0,433, 5,233] p < 0,05), IMC >= 25,0 kg/m2, (CR=0,317, IC 95% [0,782, 0,557] p < 0.05), cintura abdominal elevada (CR=0,284, IC 95% [0,054, 0,513] p < 0,05), RCQ elevada (CR=0,280, IC 95% [0,054, 0,505] p < 0,05), glicemia de jejum (CR=3,808, IC 95% [0,558, 7,058] p < 0,05), MEGA mínima (CR=4,354, IC 95% [0,821, 7,888] p < 0,05), MEGA máxima (CR=7,095, IC 95% [0,608, 13,583] p < 0,05), tamanho do lobo direito do fígado (CR=6,896, IC 95% [1,946, 11,847] p < 0,01), e com a frequência do lobo direito do fígado acima do p75 (CR=0,361, IC 95% [0,169, 0,552] p < 0,01). Ganho de peso no primeiro ano de vida menor que: a diferença entre o peso com 12 meses de idade e o peso de nascimento no p50 das curvas da Organização Mundial da Saúde, foi considerado inadequado, sendo negativamente correlacionado com EMI média da CE (CR=-0,046, IC 95% [-0,086, -0,006] p < 0,05), frequência da EMI média da CE acima do p75 (CR=-0,253, IC 95% [-0,487, -0,018] p < 0,05), EMI da (CE+CD)/2, com CR=-0,038, IC 95% [-0,073, -0,002] p < 0,05, e com a frequência da EMI (CE+CD)/2 acima do p75 (CR=-0,241, IC 95% [-0,442, -0,041] p < 0,05). CONCLUSÕES: Adultos com pesos de nascimento menores do que 2.500 g. e maiores do que 3.500 g. e com ganho de peso insuficiente no primeiro ano de vida apresentaram diferentes fenótipos metabólicos, mas todos relacionados com fatores de risco aumentados para doença cardiovascular e aterosclerose subclínica, quando comparados com aqueles que nasceram com peso adequado e com ganho de peso suficiente no primeiro ano de vida / BACKGROUND AND OBJECTIVES: Adverse conditions in the prenatal environment and in the first years of life are independently associated with increased risk for cardiovascular disease. The currently accepted hypothesis for this association is the one that states that alterations occurred during pregnancy, mainly nutritional ones, affect the organization of organs and systems that would have a lower functional capacity when needed during adult life. This paper aims to study the relationship between weight at birth, growth in the first year of life and risk factors for cardiovascular disease and subclinical atherosclerosis subclinical atherosclerosis in adults of the \"Prof. Samuel B. Pessoa\" Health Center-School (CSE) from the Medical School of the University of São Paulo. METHODS: In the year of 2009, 88 young adults aged between 20 and 31, followed since the beginning of their lives in the CSE, were submitted to the diagnosis of subclinical atherosclerosis. Their sociodemographic qualities, anthropometric data, blood pressure measurements, metabolic profile, evaluation of subclinical atherosclerosis by ultrasound and graphical methods were collected. These pieces of information were later studied according to their birth weight (< 2,500 grams and > 3,500 grams) and to the gain of weight during their first year of life. Weights were obtained from the registrations of their medical records. The current findings in the adults were analysed in relation to their conditions of birth and weight gain in the first year of life. Multivariate regressions were performed in order to obtain the statistical analyses. RESULTS: Low birth weight, less than 2,500 grams (g) was negatively correlated with higher waist-to-hip ratio (WHR), according to regression coefficient (RC) equal to -0.323, 95% CI [-0.571, -0.075] p < 0.05, diastolic blood pressure (RC=-4.744, 95% CI [-9.017, -0.470] p < 0.05), reduced HDL cholesterol (RC=-0.272, 95% CI [-0.516, - 0.029] p < 0.05), and the frequency of the intima-media thickness (IMT) of the left carotid artery average above 75th p (RC=-0.242 95% CI [-0.476, -0.008] p < 0.05). Birth weight greater than 3,500g was positively associated with BMI (RC=2.832, 95% CI [0.433, 5.233] p < 0.05), BMI >= 25.0 kg/m2, (RC=0.317, 95% CI [0.782, 0.557] p < 0.05), waist circumference elevated (RC=0.284, 95% CI [0.054, 0.513] p < 0.05), WHR elevated (RC=0.280, 95% CI [0.054, 0.505] p < 0.05), fasting glucose (RC=3.809, 95% CI [0.559, 7.058] p < 0.05), minimum subcutaneous adipose tissue (SAT) with RC=4.354, 95% CI [0.821, 7.888] p < 0.05), maximum SAT (RC=7.095, 95% CI [0.608, 13.583] p < 0.05), size right lobe of the liver (RC=6.896, 95% CI [1.946, 11.847] p < 0.01), and the frequency of the right lobe of the liver above the 75th percentile (RC=0.361, 95% CI [0.169, 0.552] p < 0.01). Weight gain in the first year of life was considered inadequate when it was lower than the difference between the weight at 12 months of age and birth weight at the 50th percentile curves of the World Health Organization (WHO), and negatively correlated with media IMT of left carotid (RC=-0.046, 95% CI [-0.086, -0.006] p < 0.05, frequency of media IMT of left carotid above the 75th percentile (RC=-0.253, 95% CI [-0.487, -0.018] p < 0.05), media IMT(left carotid + right carotid)/2 com RC=-0.038, 95% CI [-0.073, -0.002] p < 0.05, and the frequency of the media IMT (left carotid + right carotid)/2 above the 75th percentile (RC=-0.241, 95% CI [-0.442,-0.041] p < 0.05). CONCLUSIONS: Adults with weight at birth lower than 2,500 g and higher than 3,500 g and with insufficient weight gain in the first year of life have showed different metabolic phenotypes, but all related to increased risk factors for cardiovascular disease and subclinical atherosclerosis when compared to those who were born with appropriate weight and who have gained enough weight during the first year of life
15

Estudo da relação entre peso de nascimento, crescimento e aterosclerose subclínica em adultos do Centro de Saúde-Escola \"Prof. Samuel B. Pessoa\" da Faculdade de Medicina da Universidade de São Paulo / Study on the relationship between birth weight, growth, and subclinical atherosclerosis in adults at \"Prof. Samuel B. Pessoa\" Health Center-School from the Medical School of the University of São Paulo

Maria Helena Valente 12 September 2013 (has links)
JUSTIFICATIVA E OBJETIVOS: Condições adversas no ambiente pré-natal e primeiros anos de vida são independentemente associados com risco aumentado de doença cardiovascular. A hipótese aceita atualmente para essa associação é a de que agravos, principalmente nutricionais, ocorridos durante a gestação alteram a organização de órgãos e sistemas, que ao serem solicitados na vida adulta, teriam menor capacidade funcional. Com base nessa premissa, o trabalho tem o objetivo de estudar a relação entre o peso ao nascer, crescimento no primeiro ano de vida e fatores de risco para doença cardiovascular e aterosclerose subclínica em adultos do Centro de Saúde-Escola (CSE) \"Prof. Samuel B. Pessoa\" da Faculdade de Medicina da Universidade de São Paulo. MÉTODOS: Em 2009, 88 adultos jovens com idade entre 20-31 anos, seguidos desde o início da vida no CSE, foram submetidos ao diagnóstico de aterosclerose subclínica. Informações relacionadas às características sociodemográficas, dados antropométricos, medidas da pressão arterial, perfil metabólico, e avaliação da aterosclerose subclínica pela ultrassonografia e métodos gráficos foram obtidas dos adultos, e estudadas de acordo com 2 pontos de corte em relação ao peso de nascimento (< 2.500 gramas; e, > 3.500 gramas) e ganho de peso no primeiro ano de vida. Os pesos foram obtidos dos registros de prontuários. Os achados atuais dos adultos foram analisados em relação às condições de nascimento e ao ganho de peso no primeiro ano de vida. Para realização das análises estatísticas foram realizadas regressões multivariadas. RESULTADOS: Baixo peso ao nascer, menor de 2.500 gramas (g) foi negativamente correlacionado com a relação cintura-quadril (RCQ) elevada, segundo coeficiente de regressão (CR) igual a -0,323, IC 95% [-0,571, -0,075] p < 0,05, níveis de pressão arterial diastólica (CR=-4,744, IC 95% [-9,017,-0,470] p < 0,05), HDL-colesterol reduzido (CR=-0,272, IC 95% [-0,516, -0,029] p < 0,05), e frequência da espessura da média-íntima (EMI) média da carótida esquerda (CE) acima do p75 (CR=-0,242, IC 95% [-0,476,-0,008] p < 0,05). Peso ao nascer maior do que 3.500 g foi positivamente associado com IMC (CR=2,832, IC 95% [0,433, 5,233] p < 0,05), IMC >= 25,0 kg/m2, (CR=0,317, IC 95% [0,782, 0,557] p < 0.05), cintura abdominal elevada (CR=0,284, IC 95% [0,054, 0,513] p < 0,05), RCQ elevada (CR=0,280, IC 95% [0,054, 0,505] p < 0,05), glicemia de jejum (CR=3,808, IC 95% [0,558, 7,058] p < 0,05), MEGA mínima (CR=4,354, IC 95% [0,821, 7,888] p < 0,05), MEGA máxima (CR=7,095, IC 95% [0,608, 13,583] p < 0,05), tamanho do lobo direito do fígado (CR=6,896, IC 95% [1,946, 11,847] p < 0,01), e com a frequência do lobo direito do fígado acima do p75 (CR=0,361, IC 95% [0,169, 0,552] p < 0,01). Ganho de peso no primeiro ano de vida menor que: a diferença entre o peso com 12 meses de idade e o peso de nascimento no p50 das curvas da Organização Mundial da Saúde, foi considerado inadequado, sendo negativamente correlacionado com EMI média da CE (CR=-0,046, IC 95% [-0,086, -0,006] p < 0,05), frequência da EMI média da CE acima do p75 (CR=-0,253, IC 95% [-0,487, -0,018] p < 0,05), EMI da (CE+CD)/2, com CR=-0,038, IC 95% [-0,073, -0,002] p < 0,05, e com a frequência da EMI (CE+CD)/2 acima do p75 (CR=-0,241, IC 95% [-0,442, -0,041] p < 0,05). CONCLUSÕES: Adultos com pesos de nascimento menores do que 2.500 g. e maiores do que 3.500 g. e com ganho de peso insuficiente no primeiro ano de vida apresentaram diferentes fenótipos metabólicos, mas todos relacionados com fatores de risco aumentados para doença cardiovascular e aterosclerose subclínica, quando comparados com aqueles que nasceram com peso adequado e com ganho de peso suficiente no primeiro ano de vida / BACKGROUND AND OBJECTIVES: Adverse conditions in the prenatal environment and in the first years of life are independently associated with increased risk for cardiovascular disease. The currently accepted hypothesis for this association is the one that states that alterations occurred during pregnancy, mainly nutritional ones, affect the organization of organs and systems that would have a lower functional capacity when needed during adult life. This paper aims to study the relationship between weight at birth, growth in the first year of life and risk factors for cardiovascular disease and subclinical atherosclerosis subclinical atherosclerosis in adults of the \"Prof. Samuel B. Pessoa\" Health Center-School (CSE) from the Medical School of the University of São Paulo. METHODS: In the year of 2009, 88 young adults aged between 20 and 31, followed since the beginning of their lives in the CSE, were submitted to the diagnosis of subclinical atherosclerosis. Their sociodemographic qualities, anthropometric data, blood pressure measurements, metabolic profile, evaluation of subclinical atherosclerosis by ultrasound and graphical methods were collected. These pieces of information were later studied according to their birth weight (< 2,500 grams and > 3,500 grams) and to the gain of weight during their first year of life. Weights were obtained from the registrations of their medical records. The current findings in the adults were analysed in relation to their conditions of birth and weight gain in the first year of life. Multivariate regressions were performed in order to obtain the statistical analyses. RESULTS: Low birth weight, less than 2,500 grams (g) was negatively correlated with higher waist-to-hip ratio (WHR), according to regression coefficient (RC) equal to -0.323, 95% CI [-0.571, -0.075] p < 0.05, diastolic blood pressure (RC=-4.744, 95% CI [-9.017, -0.470] p < 0.05), reduced HDL cholesterol (RC=-0.272, 95% CI [-0.516, - 0.029] p < 0.05), and the frequency of the intima-media thickness (IMT) of the left carotid artery average above 75th p (RC=-0.242 95% CI [-0.476, -0.008] p < 0.05). Birth weight greater than 3,500g was positively associated with BMI (RC=2.832, 95% CI [0.433, 5.233] p < 0.05), BMI >= 25.0 kg/m2, (RC=0.317, 95% CI [0.782, 0.557] p < 0.05), waist circumference elevated (RC=0.284, 95% CI [0.054, 0.513] p < 0.05), WHR elevated (RC=0.280, 95% CI [0.054, 0.505] p < 0.05), fasting glucose (RC=3.809, 95% CI [0.559, 7.058] p < 0.05), minimum subcutaneous adipose tissue (SAT) with RC=4.354, 95% CI [0.821, 7.888] p < 0.05), maximum SAT (RC=7.095, 95% CI [0.608, 13.583] p < 0.05), size right lobe of the liver (RC=6.896, 95% CI [1.946, 11.847] p < 0.01), and the frequency of the right lobe of the liver above the 75th percentile (RC=0.361, 95% CI [0.169, 0.552] p < 0.01). Weight gain in the first year of life was considered inadequate when it was lower than the difference between the weight at 12 months of age and birth weight at the 50th percentile curves of the World Health Organization (WHO), and negatively correlated with media IMT of left carotid (RC=-0.046, 95% CI [-0.086, -0.006] p < 0.05, frequency of media IMT of left carotid above the 75th percentile (RC=-0.253, 95% CI [-0.487, -0.018] p < 0.05), media IMT(left carotid + right carotid)/2 com RC=-0.038, 95% CI [-0.073, -0.002] p < 0.05, and the frequency of the media IMT (left carotid + right carotid)/2 above the 75th percentile (RC=-0.241, 95% CI [-0.442,-0.041] p < 0.05). CONCLUSIONS: Adults with weight at birth lower than 2,500 g and higher than 3,500 g and with insufficient weight gain in the first year of life have showed different metabolic phenotypes, but all related to increased risk factors for cardiovascular disease and subclinical atherosclerosis when compared to those who were born with appropriate weight and who have gained enough weight during the first year of life

Page generated in 0.2823 seconds