• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 43
  • Tagged with
  • 43
  • 43
  • 22
  • 21
  • 16
  • 16
  • 14
  • 13
  • 12
  • 12
  • 12
  • 9
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Tecnologia alternativa em drenagem urbana: telhado verde

SILVA, Thomas Fernandes da 07 August 2017 (has links)
Submitted by Fernanda Rodrigues de Lima (fernanda.rlima@ufpe.br) on 2018-08-23T19:30:12Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇAO Thomas da Silva.pdf: 2014903 bytes, checksum: c8f0869d10c67e0e427081c3096c4ec5 (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-08-29T22:11:43Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇAO Thomas da Silva.pdf: 2014903 bytes, checksum: c8f0869d10c67e0e427081c3096c4ec5 (MD5) / Made available in DSpace on 2018-08-29T22:11:43Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇAO Thomas da Silva.pdf: 2014903 bytes, checksum: c8f0869d10c67e0e427081c3096c4ec5 (MD5) Previous issue date: 2017-08-07 / FACEPE / A urbanização de forma desordenada das cidades brasileiras proporciona a redução das áreas verdes e o aumento das áreas impermeáveis, favorecendo o aumento na velocidade do escoamento superficial, fazendo com que a água seja deslocada do ambiente o mais rápido possível, gerando áreas de inundação a jusante. As novas alternativas propostas para resolver problemas de drenagem urbana buscam, de uma forma eficiente, trata-los o mais próximo possível da fonte. Uma alternativa, natural e sustentável é a implantação dos telhados verdes, que se caracteriza pela aplicação de vegetação sobre a cobertura de edificações com impermeabilização e drenagem adequadas. Este trabalho tem a finalidade de investigar a funcionalidade de um telhado verde instalado no IPA no município de Caruaru, com relação a sua capacidade de retenção da vazão da água pluvial escoada, e avaliar o tratamento do efluente do telhado verde pelo sistema de filtração descendente em areia. Utilizou-se vegetação típica de regiões semiáridas, Babosa (Aloe Vera) e Coroa-de-Frade (Melocactus Zehntneri), e comparou-se ao telhado convencional. Após o uso de simulador de chuva, analisou-se a capacidade de retenção do telhado através do balanço hídrico no sistema. Foram realizados ensaios de bancada para avaliar a eficiência de duas configurações de filtro de areia, com diferentes granulometrias, em relação ao melhoramento da qualidade do efluente dos telhados verdes e do efluente sintético, desenvolvido em laboratório. Os telhados verdes apresentaram boa capacidade de retenção, chegando a valores de 75% e 86%, para os telhados verdes Babosa e Coroa-de-Frade, respectivamente. Observou-se um retardo na ocorrência do pico de vazão de até 14 minutos no telhado verde Babosa em relação ao telhado Convencional (telha cerâmica) e um retardo de até 21 minutos no telhado verde Coroa-de-Frade em relação ao telhado Convencional (telha cerâmica). Sendo a vegetação Coroa-de-Frade uma boa possibilidade de uso para este fim em regiões semiáridas. O desempenho do filtro foi analisado, através dos parâmetros de qualidade da água para irrigação, condutividade elétrica, sólidos dissolvidos totais, cálcio, magnésio, sódio, carbonatos, bicarbonatos, cloretos, sulfatos, nitrogênio–nitrato, nitrogênio amoniacal, fósforo–fosfato, potássio, boro, acidez ou alcalinidade e razão de adsorção de sódio. Conforme as análises observou-se que o filtro de areia apresentou-se como uma alternativa para o tratamento do efluente gerado pelo telhado verde em estudo. / The urbanization in a disorderly way of the Brazilian cities causes the reduction of green areas and the increase of impermeable areas, favoring the increase in the speed of the surface runoff, causing the water to be displaced from the environment as quickly as possible, generating flood areas downstream. The new alternatives proposed to solve problems of urban drainage seek, in an efficient way, treat them as close as possible to the source. An alternative, natural and sustainable is the implementation of green roofs, which is characterized by the application of vegetation on the roof of buildings with adequate waterproofing and drainage. This work has the purpose of investigating the functionality of a green roof installed in the IPA in the city of Caruaru, in relation to its capacity of retention of the flow of the drained pluvial water, and to evaluate the treatment of the effluent of the green roof by the system of descending filtration in sand. Typical vegetation of semi-arid regions, Babosa (Aloe Vera) and Coroa-de-Frade (Melocactus Zehntneri) was used, and compared to the conventional roof. After the use of rainfall simulator, the retention capacity of the roof was analyzed through the water balance in the system. Bench tests were carried out to evaluate the efficiency of two sand filter configurations, with different particle sizes, in relation to the improvement of the quality of green roofs and synthetic effluent, developed in the laboratory. The green roofs showed good retention capacity, reaching values of 75% and 86%, for the green roofs of Babosa and Coroa de Frade, respectively. There was a delay in the occurrence of the peak flow of up to 14 minutes on the roof of the Babosa green roof compared to the conventional roof (ceramic tile) and a delay of up to 21 minutes on the roof green Crown of Frade in relation to the conventional Roof Ceramics). Since the Coroa-de-Frade vegetation is a good possibility of use for this purpose in semi-arid regions. The performance of the filter was analyzed through water quality parameters for irrigation, Electric Conductivity, Total Dissolved Solids, Calcium, Magnesium, Sodium, Carbonates, Bicarbonates, Chlorides, Sulphates, Nitrogen-Nitrate, Ammoniacal Nitrogen, Phosphorus-Phosphate, Potassium, Boron, Acidity or Alkalinity and Sodium Adsorption Ratio. According to the analyzes, it was observed that the sand filter was may be considered as an alternative for the treatment of the effluent generated by the green roof under study.
12

Proposição de novo metodo grafico e modelo matematico para determinação das condições de funcionamento de sistemas de filtração rapida com taxa declinante

Gabriel, João Carlos, 1964- 10 June 2002 (has links)
Orientador: Carlos Gomes da Nave Mendes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-02T03:06:34Z (GMT). No. of bitstreams: 1 Gabriel_JoaoCarlos_M.pdf: 6128870 bytes, checksum: 0aab2924772151337dcab9208a393704 (MD5) Previous issue date: 2000 / Resumo: Neste trabalho, tem-se como objetivo propor uma metodologia simples, prática e até mesmo didática para a questão, através da utilização de metodologia gráfica, com a qual é possível determinar e visualizar os diferentes níveis operacionais de água e as taxas de filtração de cada um dos filtros da bateria, em condições normais ou durante a lavagem de um deles. Além disso, a partir desse método gráfico, há a propositura de apresentar uma nova modelação matemática, para a determinação algébrica dos parâmetros de projeto de operação de um sistema de filtração com taxa dec1inante variável (SFTDV). Essa proposta baseia-se no uso de dados de perda de carga total de um filtro limpo, do número de filtros da bateria, da taxa média de filtração desejada, bem como do nível máximo que a água pode atingir na caixa do filtro, de modo que não ocorra seu transbordamento , da taxa máxima de filtração, com manutenção da qualidade do efluente filtrado / Abstract: The objeetive in this work is to propose a simple, praetieal and didaetie methodology for a problem, using a graphie method, whieh is a toei to estimate the water leveI variations that will occur during operation and the water rates during normal operation of the filter bank and when the dirtiest filter is backwashed. Beside this, using this graphie method, a new mathematieal model, for algebraie determination of the design and operation parameters of a variable deelining rate filtration system, knowing the elean media head loss and turbulent head loss eoefficients, the number of filters of the bank, the mean filtration rate and the highest leveI that the water ean rieh without owerflowing the filter box or the highest filtration rate of a elean filter to maintain the effluent water quality. The mathematieal equations for a group of n filters of the bank are developed and generalized and, it is hoped with it use, obtain the optimal eonditions for design and operation for this system, showing the solution for the longest lenght of the filter run maintaining the effluent water quality ofthe filter / Mestrado / Saneamento / Mestre em Engenharia Civil
13

Sistema cantareira : estudo da potencialidade do uso da filtração direta descendente

Saron, Alexandre 14 September 2000 (has links)
Orientador : Ruben Bresaola Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-03T03:44:00Z (GMT). No. of bitstreams: 1 Saron_Alexandre_M.pdf: 3447671 bytes, checksum: 506d3817d756c0b54ba6c154f1ea454f (MD5) Previous issue date: 2000 / Resumo: Este trabalho apresenta um estudo comparativo entre duas tecnologias de tratamento de água: o tratamento convenciona_ que é utilizado na ET A Guaraú, e a filtração direta descendente. As principais diferenças entre estas tecnologias estão nas dosagens de coagulante e geração do lodo. A Estação de Tratamento de Água - ET A do Guaraú é abastecido pelo Sistema Cantareira, o qual é formado pela junção dos Rios Jaguari, Jacarei, Cachoeira, Atibaínha e Juqueri. Estes, são classificados, de acordo com a Resolução 20 do Conselho Nacional de Meio Ambiente - CONAMA de 1986, como classe 02. Nesta classe, segundo a resolução, águas de abastecimento deverão sofrer pelo menos o processo de tratamento simplificado. Foram efetuados ensaios de jarros verificando as melhores dosagens de coagulante em função do valor do pH, plotando os valores de turbidez residual em gráficos, e evidenciado os mecanismos de coagulação química. Através de análises de sólidos suspensos totais, quantificou o lodo gerado nos ensaios. Com os resultados dos ensaios de jarros, efetuou, em escala piloto, o tratamento de água pela tecnologia de filtração direta descendente. A água bruta utilizada no estudo piloto foi a mesma para ambas as tecnologias. Dois filtros piloto, de dupla camada e taxa de filtração constante foram montados. Enquanto o filtro O 1 recebia a água do processo de tratamento da ET A Guaraú, após a etapa de decantação, no filtro 02, água foi oriunda da tecnologia de filtração direta da ET A Piloto. Os ensaios foram monitorados pela evolução da perda de carga no leito filtrante e da turbidez efluente. Além desses dados, também se efetuou a quantificação do lodo gerado nas distintas tecnologias de tratamento / Abstract: The present study shows a conftontation between two drinking water treatment process: the conventional water treatment that is the actual water treatment in Guaraú Water Plant and the pilot scale direct filtration water treatment. The coagulant dosage and sludge production are differences in these processo. The Guaraú Water Plant is supply by the rivers as follow: Jaguarai, JacareÍ, Cachoeira, Atibaínha and Juqueri. In accord of the Resolution CONAMA 06/86, the specific Brazilian law for water quality, these rivers are classified in Class 2. For this Class draw water is necessary only the simplify water treatment. The better coagulant dosage was find by jar test in function of pH and turbidity analyses. With these results the coagulant diagram was realized. Through the total solids suspended analyses was quantified the sludge generated in the jar testo. The results of jar tests were utilized in the pilot scale water treatment direct filtration. Two pilot sand and coal filters with constant filtration were built. The filter number 01 received water ITom Guaraú WaterPlant decanters and the filter number 02 received the coagulated pilot scale water treatment direct filtration. The control process parameters were the pressure loss in the filters and efluent turbidity. The sludge in the different treatment technologies / Mestrado / Saneamento / Mestre em Engenharia Civil
14

Avaliação do emprego de areia de britagem como leito filtrante de filtros rápidos para tratamento de água / Evaluation of the use of crushed rock sand as filter bed for rapid filters applied for drinking water treatment

Silva, Bruno Moreno Ramos 20 February 2018 (has links)
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2018-06-14T17:22:23Z No. of bitstreams: 1 texto completo.pdf: 15547903 bytes, checksum: 62aad1568da622fa84fb1ce0bf7d1b0f (MD5) / Made available in DSpace on 2018-06-14T17:22:23Z (GMT). No. of bitstreams: 1 texto completo.pdf: 15547903 bytes, checksum: 62aad1568da622fa84fb1ce0bf7d1b0f (MD5) Previous issue date: 2018-02-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo deste trabalho foi avaliar o emprego de areia de britagem como leito filtrante de filtros rápidos descendentes no tratamento de água para consumo humano. Testes preliminares em unidade de filtração de bancada (proveta de 2 L) indicaram: (i) que o leito de areia de britagem não afeta negativamente a qualidade da água filtrada (turbidez, pH e condutividade elétrica); (ii) elevado potencial de remoção de turbidez de água decantada; (iii) eficiência da retrolavagem para limpeza do leito filtrante. Na sequência, foram realizados ensaios em duas unidades piloto de filtração rápida (construídas em tubulação de acrílico com 19 cm de diâmetro interno e comprimento total de 267 cm): um com areia de britagem e outro, como unidade de controle, com areia natural de rio. Ambos os leitos filtrantes foram preparados com granulometria e profundidade de acordo com as especificações da norma da ABNT para filtração rápida com areia natural. As duas areias foram ainda caracterizadas em termos de: composição química, massa específica, densidade aparente, porosidade, solubilidade em ácido, potencial zeta dos grãos e coeficiente de esfericidade. Ao longo de quatro meses foram monitoradas 14 carreiras de filtração, as quais foram caracterizadas, para taxas de filtração de 180, 270 e 360 m3 m'2 d'1, em termos de: (i) duração das carreiras; (ii) perda de carga ao longo do leito filtrante; (iii) remoção de turbidez ao longo do leito filtrante; (iv) índices de filtrabilidade - Índice de Ives e Índice de Hudson. Em geral, o desempenho do filtro de areia de britagem foi similar ou superior ao filtro de areia natural, produzindo água filtrada com turbidez inferior a 0,50 uT ao longo de toda a carreira, com duração e desenvolvimento da perda de carga próximos aos do filtro de areia natural. Conclui- se que a areia de britagem apresenta elevado potencial de emprego como leito filtrante de filtros rápidos para o tratamento de água para consumo humano, sem desvantagens técnicas-operacionais e com atrativos ambientais / The objective of this work was to evaluate the use of crushed rock sand as a filter bed in rapid down flow filtration for drinking water treatment. Preliminary tests using a bench-scale filtration unit (2 L measuring cylinder) indicated: (i) that the crushed rock sand bed does not negatively affect the quality of the filtered water (turbidity, pH and electrical conductivity); (ii) a high potential for turbidity removal; (iii) backwashing is efficient in cleaning the filter bed. Then, trials were carried out using two pilot-scale rapid filtration units (acrylic tubes, internal diameter of 19 cm and total length of 267 cm): one with a crushed rock sand filter bed and the other (a control unit), with natural river sand. Both filter media were prepared in accordance with the Brazilian standards for rapid down flow sand filtration (particle size range and filter bed depth), and were further characterized in terms of: chemical composition, particles density, bulk density, porosity, acid solubility, zeta potential and sphericity coefficient. Over four months, 14 filter runs using filtration rates of 180, 270 and 360 m3.m'2.d'1 were monitored and characterized in terms of (i): filter run length; (ii) head loss increase along the filter bed depth; (iii) turbidity removal along the filter bed depth; (iv) filterability indexes - Ives Index and Hudson Index. Overall, the performance of the crushed rock sand filter was similar to or even better than that of the natural river sand filter, producing filtered water with turbidity lower than 0.50 NTU along the entire filter run, with duration and head loss increasing rates similar to those of the natural sand filter. It is concluded that crushed rock sand presents a high potential for use as a filter media for rapid filtration in drinking water treatment, with environmental advantages and no technical or operational disadvantages.
15

Remoção de ferro e manganes em aguas de abastecimento, atraves de reatores granulares de fluxo ascendente : aplicação em poços profundos

Maciel, Naylson Moreira 20 July 1999 (has links)
Orientador: Ruben Bresaola Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-07-25T20:39:30Z (GMT). No. of bitstreams: 1 Maciel_NaylsonMoreira_M.pdf: 6635503 bytes, checksum: c29c7e2180adfac9b8dd6586ed17d872 (MD5) Previous issue date: 1999 / Resumo: Muitas regiões brasileiras apresentam problemas qualitativos em seus aqüíferos subterrâneos, utilizados para abastecimento público, relacionados à presença de sais de ferro e manganês, que decorrem da dissolução de rochas e minerais. Podem trazer inconvenientes como a formação de precipitados, presença de manchas em sanitários, roupas e utensílios domésticos, problemas de sabor e odor, incrustações nas canalizações, proliferação de bactérias ferruginosas, assim como prejuízos na indústria. O projeto desenvolvido consistiu na adequação e junção das técnicas de pré-filtração, utilizando filtros de pedregulho de fluxo ascendente, com aplicação prévia dos produtos químicos oxidantes, permanganato de potássio e hipoclorito de sódio, visando a remoção dos compostos de ferro e manganês das águas subterrâneas através de um sistema simplificado, de manutenção não complexa e baixo custo de implementação. Tanto o permanganato quanto o cloro proporcionaram remoções de sais de ferro e manganês, para valores abaixo dos recomendados pela Portaria nO36do Ministério da Saúde do Brasil, e ambos mostraram-se como boa alternativa de tratamento. O uso de uma unidade sem adição de oxidantes indicou a importância do meio filtrante no processo de remoção, atingindo porcentagens de 96 e 94%, para sais ferro e manganês, respectivamente, embora nunca estando abaixo dos mínimos recomendados pela Portaria n° 36...Observação: O resumo, na íntegra, poderá ser visualizado no texto completo da tese digital / Abstract: Many Brazilian regions present qualitative problems in their groundwaters, used for public supply, due to the presence of iron and manganese, that come from the dissolution of rocks and mineraIs. They can bring inconveniences as the formation of precipitated material, presence of spots in toilets, clothes and domestic utensils, problems of fiavor and smell, incrustations in pipes, proliferation of ironbacterium, as well as damages in the industry. Different processes for the removal of these elements from water are known. This present design consisted of the adequacy and junction of the filtration techniques, using pebble filters with ascending stream, with previous application of the chemical products, pot assium permanganate and sodium hipoc1orite, aiming at the removal of iron and manganese composites from underground waters throught a simplified system, that presents not complex aintenance and low cost of implementation. As much the permanganate as the chlorine had provided removals of iron and manganese, to values below of that recommended by Brazilian Health Ministery, and the both had revealed good as an altemative oftreatment. The use of an unit without oxidants products showed the importance of the filter media in remotion, going to taxes of 96 and 94%, for iron and manganese salts, respectivily, spite of never being under the minimals recommeded by Brazilian Health Ministery...Note: The complete abstract is available with the full electronic digital thesis or dissertations / Mestrado / Saneamento / Mestre em Engenharia Civil
16

Caracterização do efluente de uma vinícola na região do Vale do Rio Peixe/SC e avaliação do seu tratamento por biofiltro aerado submerso

Ortigara, Angela Renata Cordeiro January 2009 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Ambiental / Made available in DSpace on 2012-10-24T21:42:05Z (GMT). No. of bitstreams: 1 265978.pdf: 4440700 bytes, checksum: ba19c197a3b5f29e979a2708b2be6be1 (MD5) / O presente estudo teve como objetivo avaliar as variações na composição quali-quantitativa dos efluentes líquidos gerados por uma vinícola e o comportamento do tratamento destes efluentes em reatores do tipo Biofiltro Aerado Submerso com preenchimento de cascas de ostras. A etapa experimental foi realizada no período de 28/01/2008 a 20/12/2008. Estudou-se o fluxograma do processo produtivo, identificando-se os principais resíduos gerados, a variação do consumo de água e as características do efluente líquido em dois períodos distintos: a safra e a entressafra, além da avaliação do tratamento deste efluente por Biofiltro Aerado Submerso (BAS). Os principais subprodutos gerados pela atividade são provenientes da uva (engaço, cascas, sementes, borra) e do processo produtivo (bentonite e terras de filtração). A vínicola apresentou um índice de consumo de 1,78 L de água/L de vinho produzido. A Amostragem Composta apresentou valores de 9.090 mgDQO/L para o período da safra e para a entressafra, 8.260 mgDQO/L. As atividades que apresentaram valores mais elevados de consumo de água e de geração de carga orgânica foram a lavagem de filtros, pipas, prensas e pisos. De acordo com avaliação, o efluente apresentou pH médio de 4,5 e alcalinidade de 60,4 mgCaCO3/L, e concentrações de carbono, nitrogênio e fósforo inadequadas ao tratamento biológico (100/0,25/0,25). Para avaliar a tratabilidade do efluente vinícola pelo BAS, preenchido com casca de ostra, foram utilizados dois reatores em escala laboratorial: um alimentado com o efluente da safra (BAS 1) e o outro com efluente da entressafra (BAS 2). Para a realização dos testes, o efluente homogeinizado teve suas características avaliadas, e o balanço nutricional ajustado com a adição de cloreto de amônio (NH4CL) e fosfato de potássio bibásico (K2HPO4). Foram considerados três períodos operacionais com duração de 5 semanas cada e com o mesmo tempo de detenção hidráulica (24 horas). No Período 1, a alimentação dos reatores foi descontínua com cargas variávies, no Período 2, manteve-se a alimentação descontínua e as cargas abaixo de 5 kgDQO/m³ e no Período 3, o reator foi alimentado de forma contínua com cargas abaixo de 5 kgDQO/m³. O meio filtrante foi capaz de conferir alcalinidade ao sistema e aumentar o pH nos reatores para valores de aproximadamente 6,7. O Período 3 apresentou as melhores eficiências de remoção de DQO, 90% para o BAS 1 e 82% para o BAS 2. Não ocorreu remoção média de nitrogênio no BAS 1, e no BAS 2, apenas 31%. A remoção máxima de fósforo foi de 58% e 53% nos BAS 1 e 2, respectivamente. Quanto aos metais, apenas os valores médios de cobre nos efluentes dos biofiltros estavam acima de 0,5 mg/L, valor máximo permitido pelo Decreto Estadual 14.250/1981. Constatou-se que o emprego de BAS, operando em fluxo contínuo pode ser uma alternativa para o tratamento de efluentes vinícolas na região de estudo.
17

Avaliação da nitrificação e desnitrificação de esgoto doméstico empregando filtros plantados com macrófitas (wetlands) de fluxos vertical e horizontal

Olijnyk, Débora Parcias January 2008 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pos-Graduação em Engenharia Ambiental. / Made available in DSpace on 2012-10-24T04:31:13Z (GMT). No. of bitstreams: 1 252380.pdf: 2938591 bytes, checksum: 1004041f4b39268bfdbae0e43a0ca4cb (MD5) / Filtros plantados com macrófitas (wetlands) são sistemas naturais utilizados, principalmente, para o tratamento de esgotos. Apresentam como vantagem o baixo custo de operação, baixo consumo energético e simplicidade operacional, podendo, desta forma, ser aplicados no tratamento de esgotos de residências, empresas, pequenas comunidades e na área rural. Quando se deseja obter um tratamento mais avançado em relação à remoção de nitrogênio, é possível combinar os filtros plantados de fluxo vertical (FPMV) aos de fluxo horizontal (FPMH), conhecidos como sistemas híbridos. Neste contexto, o presente trabalho objetivou avaliar a nitrificação e desnitrificação de esgotos domésticos por meio de sistemas híbridos de filtros plantados com macrófitas. A pesquisa consistiu no estudo de seis unidades piloto de FPMV plantados com Typha domingensis, sendo que estas unidades foram diferenciadas em relação às cargas superficiais aplicadas (variando entre 19,5gSS/m².d e 27,5gSS/m².d e variando entre 10,1gNH4-N/m².d e 14,1gNH4-N/m².d) e em relação à espessura da camada de areia utilizada como material filtrante (30cm e 60cm). Os efluentes destas seis unidades foram conduzidos para dois FPMH (10,0m² e 0,60m de profundidade, cada módulo), também com T. domingensis, que foram diferenciadas pelo material utilizado no leito filtrante (brita e areia), pelo tempo de operação de cada módulo (operando a 1 ano e a 3 anos) e pelas cargas transversais aplicadas (24,7gSS/m².d e 16,1gSS/m².d). Todas as unidades experimentais foram avaliadas ao longo de 1 ano por meio de parâmetros físico-químicos e bacteriológicos do esgoto com a utilização do teste de variância ANOVA. Como resultados obtiveram-se remoções de NH4-N nos FPMV variando entre 56%-74%, entretanto baixas produções de NO3-N foram observadas, concluindo-se que a nitrificação não foi muito efetiva nos FPMV. As análises estatísticas mostraram poucas diferenças nos filtros com diferentes profundidades. Em relação às diferentes cargas aplicadas, não foi encontrada relação entre as mesmas e a nitrificação do sistema. A principal forma de remoção nos FPMV foi atribuída à acumulação de detritos nos poros do material filtrante. Nos FPMH foi observado um melhor desempenho no filtro com areia em termos de NH4-N, DQO, SS e PO4-P, mesmo este estando em operação há mais tempo e apresentando problemas de escoamento superficial em decorrência da colmatação da porção inicial do leito filtrante. As taxas de desnitrificação nos FPMH foram elevadas, entretanto em termos de concentração, as remoções de NO3-N foram baixas devido às baixas concentrações afluentes. Os efluentes das seqüências tecnológicas apresentaram valores que se adéquam à legislação em termos de nitrogênio, podendo ser recomendadas como forma de polimento de estações de tratamento de esgoto que não se enquadrem na legislação.
18

Aplicação da filtração intermitente em leito de areia e de escória da metalurgia do cobre no tratamento de esgotos com ênfase em reuso.

Dultra, Fernando de Almeida 23 March 2007 (has links)
Submitted by infopei ufba (infopei@ufba.br) on 2016-12-07T20:19:03Z No. of bitstreams: 1 dis_fernando_dultra.pdf: 2853632 bytes, checksum: d49c5048b5752d02d081d6d5c1615a1b (MD5) / Approved for entry into archive by Escola Politécnica Biblioteca (biengproc@ufba.br) on 2017-03-16T12:34:41Z (GMT) No. of bitstreams: 1 dis_fernando_dultra.pdf: 2853632 bytes, checksum: d49c5048b5752d02d081d6d5c1615a1b (MD5) / Made available in DSpace on 2017-03-16T12:34:41Z (GMT). No. of bitstreams: 1 dis_fernando_dultra.pdf: 2853632 bytes, checksum: d49c5048b5752d02d081d6d5c1615a1b (MD5) / PROSAB,FINEP,CNPq, FAPESB,PROSAB, FAPESB,LABDEA, Acquabrasillis,Caraíba Metais, Pedreiras Limoeiro, Construtora NM / Este trabalho teve por objetivo avaliar o desempenho de filtros intermitentes, no póstratamento de esgotos sanitários. Primeiramente, o efluente tratado proveio de um sistema composto por um decantador primário, um contactor biológico rotativo - CBR, e um decantador secundário. Na segunda fase o CBR saiu de operação, ficando o tratamento preliminar reduzido a decanto-digestão em três câmaras sépticas, com seis horas de detenção hidráulica. A unidade experimental é composta de doze unidades de filtros intermitentes sendo oito de areia, três de escória de metalurgia de cobre, e uma mista. O sistema trata os esgotos da Escola Politécnica da Universidade Federal da Bahia. Cada filtro tem 0,5 m de altura de leito filtrante, com tamanhos efetivos-TE de 0,4 mm, 0,75 mm, 1,3 mm de areia e 1,2 mm de escória, os coeficientes de uniformidade variaram de 1,13 a 1,83. As taxas de aplicação hidráulica foram de 0,4 m³/m².dia, 1,1 m³/m².dia e 1,4 m³/m².dia, com freqüência de aplicação de doses de 48 vezes por dia. Mesmo com taxas de aplicação mais elevadas que aquelas relatadas em outros trabalhos, obteve-se resultados satisfatórios quanto à remoção de matéria orgânica, ficando a DBO abaixo de 10 mg/L e SST em torno de 5 mg/L. Com respeito a eficiência de redução da matéria orgânica, constata-se que para as elevadas taxas de aplicação, não há diferença significativa entre os diversos TE’s dos leitos filtrantes.Conclui-se que é possível obter efluentes de boa qualidade, operando filtros intermitentes com elevadas taxas de aplicação hidráulica, com leitos de tamanhos efetivos acima de 1,0 mm, sem finos, apresentando carreiras superiores a um ano, o que significa uma diminuta geração de lodo. Os filtros intermitentes, são unidades aeróbias, não geram odores, não geram aerossóis, têm baixo custo operacional, não requerem mão de obra especializada, sua manutenção é simples e econômica, e praticamente não geram lodo. Sua capacidade de abater microrganismos é limitada, principalmente para taxas mais elevadas, porem o efluente é muito clarificado possibilitando a aplicação de diversos processos de desinfecção. Podem ser usados amplamente no tratamento de esgotos de pequenos geradores, de forma descentralizada e possibilitando o reúso. / This work had the objective of evaluating the performance of intermittent sand filters, in the post-treatment of sanitary sewers. First, the treated effluent was from a system composed of a primary decanter, a rotating biological contactor - RBC, and a secondary decanter. In the second phase the RBC left operation, and the preliminary treatment was reduced to decant-digestion in three septic chambers, with six hours of hydraulic detention. The experimental unit is composed of twelve units of intermittent filters which eight of sand, three of slag of copper metallurgy, and one mixing. The system treated the sanitary sewers of the Polytechnic School of the Federal University of Bahia. Each filter had 0,5 m of height of filter stream bed, with effective sizes-ES of 0,4 mm, 0,75 mm, 1,3 mm of sand and 1,2 mm of slag, uniformity coefficients ranged of 1,13 up to 1,83. Rates of hydraulic application had been of 0,4 m ³ /m ².day, 1.1 m ³ /m ².day and 1,4 m ³ /m ².day, with application frequency of doses of 48 times per day. Even with rates of application higher than those reported in other works, it was gotten satisfactory results respecting to the removal of organic matter, with BOD below 10 mg/L and SST around 5 mg/L. Concerning to the organic matter efficiency reduction, one evidences that for the high rates of application, there was no significant difference between diverse ES of the filter stream beds. One concludes that it is possible to get good quality effluent, operating intermittent sand filters with high rates of hydraulic application, with stream beds of effective sizes above 1,0 mm, without fines, presenting careers superior to one year, meaning a low generation of sludge. The intermittent filters are aerobic units, do not generate odors, do not generate aerosols, have low operational cost, do not require skilled worker, its maintenance is easy and economic and they practically do not generate sludge. Its capacity to reduce microorganisms is limited, mainly for higher rates; however the effluent is very clear making possible the application of various disinfection processes. They can be widely used in treatment sewers of small sources, in decentralized way and making reuse possible.
19

Comportamento de filtro plantado horizontal (wetlands construídos) no tratamento de esgoto unifamiliar

Guimarães, Tarcio Moreno Veloso de Andrade January 2013 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2013. / Made available in DSpace on 2014-08-06T17:52:02Z (GMT). No. of bitstreams: 1 322568.pdf: 2253344 bytes, checksum: 5d6bb5acc1500e6445c6dc50adbf7385 (MD5) Previous issue date: 2013 / Filtros plantados com escoamento horizontal subsuperficial (FHSS) são de grande interesse no tratamento de esgoto doméstico, devido à boa eficiência e aos baixos custos de implantação e manutenção. Para o dimensionamento adequado desses sistemas, é necessária uma compreensão sólida dos processos físicos e bioquímicos que se combinam para remover os poluentes. Contribuem nestes processos: solo, microrganismos, plantas e principalmente comportamento hidrodinâmico do fluido dentro do filtro. Considerando a importância da microbiota e do comportamento hidrodinâmico nos processos de tratamento de esgoto em FHSS, além da avaliação da eficiência de tratamento, foi desenvolvido um estudo microbiológico do meio filtrante e um teste com traçador químico (NaCl). É um sistema residencial (4 pessoas; 0,27 m³ dia-1), com tratamento primário em tanque séptico, seguido de um FHSS. Foram avaliados os principais parâmetros físico-químicos e biológicos do esgoto na entrada e na saída do sistema. No meio filtrante, foram avaliadas as concentrações de bactérias heterotróficas, sólidos voláteis e microrganismos visualizados por microscopia. O FHSS apresentou, ao longo de 17 meses, eficiência satisfatória, removendo, em média, 18,7 e 3,2 g m² dia-1 de DQO e sólidos suspensos, respectivamente, o que corresponde a eficiências de 80%. Com relação à microfauna avaliada no leito filtrante, os microrganismos mais abundantes foram os ciliados, seguidos por nematoides. A concentração de microrganismos foi correlacionada positivamente com a concentração de matéria orgânica e de oxigênio. No teste com traçador foi obtida uma eficiência volumétrica de 1,14 e um tempo de detenção hidráulico médio de aproximadamente 5 dias. Foi obtido um valor de 0,02 para o número de dispersão (d). Os valores obtidos para os coeficientes de cinética de primeira ordem de remoção de DQO, para os modelos clássicos aplicados aos dados do FHSS foram de 0,35 ? 0,44 d-1. Estes dados contribuem para o dimensionamento de filtros plantados, preenchidos com areia, aplicados em escala residencial para o tratamento de esgotos. <br>
20

Remoção de oocistos de Cryptosporidium por meio da filtração direta ascendente em areia : avaliação em escala piloto.

Nascimento, Marcely Ferreira 21 December 2009 (has links)
Dissertação (Mestrado em Tecnologia Ambiental e Recursos Hídricos)-Universidade de Brasília, Brasília, 2009. / Submitted by Luiza Moreira Camargo (luizaamc@gmail.com) on 2011-07-05T16:33:30Z No. of bitstreams: 1 2009_MarcelyFerreiraNascimento.pdf: 4078879 bytes, checksum: c6e557f5165ad0b2f47fa09946ad8df4 (MD5) / Approved for entry into archive by Jaqueline Ferreira de Souza(jaquefs.braz@gmail.com) on 2011-07-08T14:41:28Z (GMT) No. of bitstreams: 1 2009_MarcelyFerreiraNascimento.pdf: 4078879 bytes, checksum: c6e557f5165ad0b2f47fa09946ad8df4 (MD5) / Made available in DSpace on 2011-07-08T14:41:28Z (GMT). No. of bitstreams: 1 2009_MarcelyFerreiraNascimento.pdf: 4078879 bytes, checksum: c6e557f5165ad0b2f47fa09946ad8df4 (MD5) / Dentre as doenças de veiculação hídrica que vêm recebendo maior atenção nos últimos anos, destaca-se a Criptosporidiose que é causada pelo protozoário Cryptosporidium. Os oocistos de Cryptosporidium são resistentes ao estresse ambiental e à inativação por cloro e, devido ao seu tamanho, têm facilidade para passar através do processo de tratamento físico de água. Nesse contexto, o presente trabalho teve como objetivo avaliar a remoção de oocistos de Cryptosporidium parvum por meio da filtração direta ascendente em areia. Os experimentos de filtração direta ascendente, em escala piloto, foram realizados com água proveniente do Lago Paranoá inoculada com oocistos de Cryptosporidium parvum de modo a se obter concentração da ordem de 103 ooc./L na água de estudo. A taxa de filtração adotada foi de 120m³/m².d. Em nove experimentos de filtração a água de estudo apresentava valores baixos de turbidez (2,7 a 4,8 UT) e em três experimentos a turbidez era de cerca de 30 UT. Os resultados revelaram que a eficiência de remoção de oocistos de Cryptosporidium parvum no início do experimento de filtração foi, em média, 0,5 log menor que no período de funcionamento estável, em que a remoção média de oocistos de Cryptosporidium parvum foi de 3,5 log. Os valores de turbidez na água filtrada foram inferiores ao limite de 0,5 UT recomendado na legislação brasileira, Portaria MS No. 518/2004, e também inferiores ao limite da legislação americana (0,3 UT), exceto nos experimentos com turbidez mais elevada. A concentração de oocistos de Cryptosporidium parvum na água de lavagem do filtro confirmou o elevado risco de contaminação microbiológica desse resíduo. O tratamento estatístico dos dados indicou que na água filtrada não houve correlação significativa entre a concentração de oocistos de Cryptosporidium parvum e os parâmetros turbidez, coliformes totais e E.coli. Correlação fraca foi observada entre oocistos de Cryptosporidium parvum e contagem de partículas nas faixas de tamanho do oocisto de Cryptosporidium. Os resultados revelam que os filtros rápidos ascendentes apresentam eficiências de remoção de oocistos de Cryptosporidium parvum similares aos filtros rápidos descendentes. _______________________________________________________________________________ ABSTRACT / Among the waterborne diseases that have received increased attention in recent years stands out Cryptosporidiosis, which is caused by the parasite protozoan Cryptosporidium. Cryptosporidium oocysts are resistant to environmental stress and inactivation by chlorine and, due to their size,, may pass through the physical treatment processes of water. In this context, this study aimed to evaluate the removal of Cryptosporidium oocysts by up flow direct sand filtration. The experiments in pilot scale were carried out with Paranoá lake water spiked with Cryptosporidium parvum oocysts in order to obtain concentration of about 103 ooc./L in the study water. The filtration rate adopted was 120m³/m².d. In nine experiments the study water presented low levels of turbidity (2.7 to 4.8 NTU) and in three experiments the turbidity was of around 30 NTU. The results showed that the removal efficiency of Cryptosporidium parvum oocysts in the early stages of the filtration experiments was, in average 0.5 log lower than during filtration steady state where the average removal of Cryptosporidium parvum oocysts was 3.5 log. The values of turbidity in filtered water were below the limit of 0.5 NTU recommended by UT Brazilian Health Authority, Decree MS No. 518/2004, and also below the limit set by U.S. legislation (0.3 NTU), except in experiments with study water with higher turbidity. The concentration of Cryptosporidium parvum oocysts in the filter backwash water confirmed the high risk of microbiological contamination of the this waste. Statistical analysis indicated that there was no significant correlation between the concentration of Cryptosporidium parvum oocysts and characteristics such as turbidity, total coliform and E.coli in the filtered water. Weak correlation was found between Cryptosporidium parvum oocysts and particle counting in size range of Cryptosporidium oocyst. The results suggest that up flow direct filtration has similar removal efficiency of Cryptosporidium oocysts when compared with down flow filtration.

Page generated in 0.0548 seconds