• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 622
  • 57
  • 3
  • 2
  • 2
  • 1
  • Tagged with
  • 691
  • 365
  • 253
  • 191
  • 115
  • 98
  • 84
  • 73
  • 73
  • 72
  • 55
  • 55
  • 50
  • 48
  • 43
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Incidência de cancro cítrico (Xanthomonas citri pv. citri) em pomar de laranjeiras 'Valência' sob concentrações e freqüências de pulverizações cúpricas

Theisen, Sergiomar January 2004 (has links)
O objetivo deste trabalho foi de buscar alternativas para aumentar a eficiência do controle do cancro cítrico (Xanthomonas citri pv. citri) nos pomares do Rio Grande do Sul, avaliando o efeito de concentrações de três bactericidas cúpricos e de duas freqüências de pulverização nas fases de intensa brotação.
42

Modificação superficial do PET (Poli Tereftalato de Etileno) para beneficiamento na reciclagem

Oliveira, Anie Karina da Rosa January 2011 (has links)
Nos últimos anos, o crescente consumo de materiais poliméricos, e por conseqüência a grande quantidade de resíduos gerados tem aumentado a necessidade de reciclagem desses materiais descartados. Tendo em vista a problemática da elevada variedade de polímeros pós-consumo e a dificuldade na separação de mistura destes, neste trabalho foi estudada a separação do PVC de misturas pós-consumo de PET e PVC, já que este é um polímero indesejado na indústria de reciclagem de PET, pela técnica de flotação, com prévio tratamento superficial. Para avaliar a melhor eficiência de separação, amostras de PET e PVC foram submetidas a diversos tratamentos termoquímicos com soluções de NaOH e de detergente (DT) nas concentrações de 1, 2 e 4%, em temperatura de 25 e 60ºC e tempo de lavagem de 10, 20 e 30min. Após as lavagens, as amostras foram enxaguadas em água e submetidas à secagem em estufa com circulação de ar por períodos de 3 e 24h. As amostras foram caracterizadas por ensaios físicos (densidade, ângulo de contato, energia de superfície, MEV e flotação); reológicos (viscosidade intrínseca); químicos (método de Pohl e FTIR-ATR); e ensaios térmicos (DSC e TGA). No ensaio de flotação foi utilizado metil iso-butil carbinol (MIBC) como agente tensoativo, cuja concentração usada foi de 0,15% e pH 9,0. Os resultados do ensaio de flotação indicaram que as amostras tratadas com NaOH apresentaram maior eficiência de separação do PVC. Nos demais ensaios, os resultados comprovaram que a melhor eficiência na modificação da tensão superficial ocorreu nas amostras tratadas com as soluções de NaOH do que nas amostras tratadas com DT. As amostras tratadas com DT também tiveram modificação da tensão superficial, porém não foi tão eficiente quanto a das amostras tratadas com NaOH. Também foi possível comprovar que mesmo com a alteração da tensão superficial, não ocorreram grandes alterações na densidade e viscosidade do polímero reciclado. Com a finalização deste trabalho, foi possível observar que os melhores resultados de modificação superficial do PET ocorreram quando ele foi tratado com as soluções de NaOH, e que quando a solução é de baixa concentração, a temperatura de lavagem controlada e maior tempo de secagem, não ocorrem grandes perdas nas propriedades físicas, químicas e reológicas do PET. / In recent years, the increasing use of polymeric materials, and hence the large amount of waste generated has increased the need for recycling of discarded materials. Given the variety of problems post-consumer polymers and the difficulty in to separate the mixture of these, in this work the separation of PVC in mixtures of post-consumer PET and PVC, already that it is an unwanted polymer in the recycling industry PET, by flotation technique, with prior surface treatment. To evaluate the best separation efficiency, PET and PVC sample were subjected to various thermalchemical treatments, in NaOH and detergent (DT) solutions, at concentrations of 1, 2 and 4% wt at temperatures of 25 and 60 ° C, and washing time of 10, 20 and 30 minutes. After washes, samples were rinsed in water and dried in an oven with air circulation for periods of 3 and 24 h. The samples were characterized by physical tests (density, contact angle, surface energy, SEM and flotation), rheological (intrinsic viscosity), chemical (method of Pohl and ATR-FTIR) and thermal (DSC and TGA). In the flotation test was used methyl isobutyl carbinol (MIBC) as surfactant, whose concentration used was of 0.15% and pH 9.0. Results of the flotation test indicated that the samples treated with NaOH had higher separation efficiency of PVC. Results showed that the best efficiency of modification of the surfacial tension occurred in the samples treated with NaOH solutions when compared with samples treated with DT. Samples were also treated with DT modification of surface tension, but it was not as efficient as that of samples treated with NaOH. It was also possible to prove that even with the change of surface tension, there were no major changes in the density and viscosity of the polymer recycled. With the completion of this work, it was observed that the best results for surface modification of PET occurred when it was treated with NaOH solutions, and when the solution was of low concentration, washing temperature controlled and an increase of the drying time, any losses in physical, chemical and rheological properties of PET were observed.
43

Modificação superficial do PET (Poli Tereftalato de Etileno) para beneficiamento na reciclagem

Oliveira, Anie Karina da Rosa January 2011 (has links)
Nos últimos anos, o crescente consumo de materiais poliméricos, e por conseqüência a grande quantidade de resíduos gerados tem aumentado a necessidade de reciclagem desses materiais descartados. Tendo em vista a problemática da elevada variedade de polímeros pós-consumo e a dificuldade na separação de mistura destes, neste trabalho foi estudada a separação do PVC de misturas pós-consumo de PET e PVC, já que este é um polímero indesejado na indústria de reciclagem de PET, pela técnica de flotação, com prévio tratamento superficial. Para avaliar a melhor eficiência de separação, amostras de PET e PVC foram submetidas a diversos tratamentos termoquímicos com soluções de NaOH e de detergente (DT) nas concentrações de 1, 2 e 4%, em temperatura de 25 e 60ºC e tempo de lavagem de 10, 20 e 30min. Após as lavagens, as amostras foram enxaguadas em água e submetidas à secagem em estufa com circulação de ar por períodos de 3 e 24h. As amostras foram caracterizadas por ensaios físicos (densidade, ângulo de contato, energia de superfície, MEV e flotação); reológicos (viscosidade intrínseca); químicos (método de Pohl e FTIR-ATR); e ensaios térmicos (DSC e TGA). No ensaio de flotação foi utilizado metil iso-butil carbinol (MIBC) como agente tensoativo, cuja concentração usada foi de 0,15% e pH 9,0. Os resultados do ensaio de flotação indicaram que as amostras tratadas com NaOH apresentaram maior eficiência de separação do PVC. Nos demais ensaios, os resultados comprovaram que a melhor eficiência na modificação da tensão superficial ocorreu nas amostras tratadas com as soluções de NaOH do que nas amostras tratadas com DT. As amostras tratadas com DT também tiveram modificação da tensão superficial, porém não foi tão eficiente quanto a das amostras tratadas com NaOH. Também foi possível comprovar que mesmo com a alteração da tensão superficial, não ocorreram grandes alterações na densidade e viscosidade do polímero reciclado. Com a finalização deste trabalho, foi possível observar que os melhores resultados de modificação superficial do PET ocorreram quando ele foi tratado com as soluções de NaOH, e que quando a solução é de baixa concentração, a temperatura de lavagem controlada e maior tempo de secagem, não ocorrem grandes perdas nas propriedades físicas, químicas e reológicas do PET. / In recent years, the increasing use of polymeric materials, and hence the large amount of waste generated has increased the need for recycling of discarded materials. Given the variety of problems post-consumer polymers and the difficulty in to separate the mixture of these, in this work the separation of PVC in mixtures of post-consumer PET and PVC, already that it is an unwanted polymer in the recycling industry PET, by flotation technique, with prior surface treatment. To evaluate the best separation efficiency, PET and PVC sample were subjected to various thermalchemical treatments, in NaOH and detergent (DT) solutions, at concentrations of 1, 2 and 4% wt at temperatures of 25 and 60 ° C, and washing time of 10, 20 and 30 minutes. After washes, samples were rinsed in water and dried in an oven with air circulation for periods of 3 and 24 h. The samples were characterized by physical tests (density, contact angle, surface energy, SEM and flotation), rheological (intrinsic viscosity), chemical (method of Pohl and ATR-FTIR) and thermal (DSC and TGA). In the flotation test was used methyl isobutyl carbinol (MIBC) as surfactant, whose concentration used was of 0.15% and pH 9.0. Results of the flotation test indicated that the samples treated with NaOH had higher separation efficiency of PVC. Results showed that the best efficiency of modification of the surfacial tension occurred in the samples treated with NaOH solutions when compared with samples treated with DT. Samples were also treated with DT modification of surface tension, but it was not as efficient as that of samples treated with NaOH. It was also possible to prove that even with the change of surface tension, there were no major changes in the density and viscosity of the polymer recycled. With the completion of this work, it was observed that the best results for surface modification of PET occurred when it was treated with NaOH solutions, and when the solution was of low concentration, washing temperature controlled and an increase of the drying time, any losses in physical, chemical and rheological properties of PET were observed.
44

Modelagem da copolimerização de olefinas : estudo da aplicabilidade de dados em fase líquida para a fase gás

Flores, Tanise Mori January 2006 (has links)
Reações de polimerização em reatores fase gás é o processo mais utilizado atualmente na produção de poliolefinas. Entretanto, existe grande dificuldade de reproduzir um reator em fase gás em escala laboratorial, devido à presença de uma fase sólida e uma fase gasosa em ausência de solvente, a agitação e remoção de calor. O presente trabalho visa uma melhor compreensão dos processos de copolimerização de eteno e buteno, com catalisadores Ziegler-Natta em reatores fase gás e fase líquida a fim de aplicar os resultados obtidos em um reator fase líquida de laboratório em um reator fase gás industrial. A possibilidade de aplicação destes resultados é estudada através da modelagem matemática fenomenológica dos processos. O processo estudado é a copolimerização de eteno e buteno com catalisadores Ziegler-Natta para produção de polietileno linear de baixa densidade em reatores tipo Spherilene. Após ajuste dos modelos para o reator fase líquida e o reator fase gás, efetuaram-se análises de sensibilidade paramétrica para verificar o comportamento das variáveis de saída. A metodologia utilizada para determinação dos critérios de comparação dos dois modelos foi estabelecer um planejamento experimental no processo fase gás, baseado na análise de sensibilidade, utilizando-se as variáveis de saída desse modelo para se obter as condições de operação do reator fase líquida. Essas condições foram relacionadas com as propriedades finais do polímero do reator em fase gás através da temperatura e relações de C4/C2 e H2/C2. A metodologia apresentada permite avaliar as condições adequadas para operar o reator laboratorial em fase líquida e obter dados que podem ser utilizados no estudo do reator fase gás. Os valores obtidos para as constantes cinéticas estão diretamente ligados ao tipo de processo utilizado, utilização ou não de solvente, remoção de calor e outros critérios que diferenciam o processo em fase líquida do processo em fase gás. Logo, aplicando os fatores de correção às constantes cinéticas obtém-se, no reator em fase líquida, um polímero com propriedades finais muito semelhantes ao produto obtido no reator em fase gás de leito fluidizado, considerando as diferenças de processo. / Polymerizations reactions in gas-phase reactors are the utmost process used nowadays for the production of polyolefin. However, it is very difficult to reproduce a gas-phase reactor in a laboratorial scale, due to the presence of solid and gas phases and absence of diluents, the mixing and heat removal. The present work seeks a better understanding of the copolymerization processes of etene/1-butene with Ziegler-Natta catalyst in phase-gas and liquid-phase reactors in order to apply the results obtained in a liquid-phase laboratory reactor in a gas-phase industrial reactor. The possibility of application of these results is studied through the phenomenological mathematical modeling of the processes. The polymerization process studied is the copolymerization of etene/1-butene with Ziegler-Natta catalyst for the production of low density linear polyethylene in a Spherilene reactor. After adjustment in the liquid and gas-phase model, parametric sensitivity analysis were made to evaluate the behavior of the output variables. The methodology used to determinate the comparison criteria was established by experimental design in the gas-phase model, based on the sensitivity analysis results. The output variables of the gas-phase model were used in order to obtain the operating conditions of the liquid-phase reactor. These operating conditions were linked to the final polymer properties through variables such as temperature, C4/C2 and H2/C2 ratios. The presented methodology allows the evaluation of the operating conditions of the laboratory-scale liquid-phase reactor and the collection of data to be used in gas-phase reactors studies. The value obtained to the kinetic constants is directly connected to the kind of process used, presence or absence of diluents, heat removal and other criteria that differentiate both processes. Therefore, the application of correcting factors to the kinetic constants produce, in the laboratory-scale liquid-phase reactor, polymers with final properties very similar to the polymer obtained in the industrial gas-phase reactor, considering all the differences in the process.
45

Epidemiologia e controle de fuligem e sujeira de mosca em macieiras (Malus x domestica Borkh) no Sul do Brasil / Epidemiology and control of sooth blotch and flyspeck on apples (Malus x domestica Borkh.) in southern Brazil

Spolti, Piérri January 2009 (has links)
A cultura da macieira no Brasil ocupa uma área de 35 mil hectares, concentrada nos estados do Sul do país. Apesar do alto patamar técnico atingido, a cultura sofre o ataque e perdas por inúmeras doenças, dentre as quais, incluem-se a Fuligem e a Sujeira de Mosca (F&SM). Classificadas como doenças secundárias, reduzem o valor de comercialização dos frutos in natura, pela formação de manchas escuras na epiderme dos frutos como resultado da colonização epífita por fungos na superfície das maçãs. No Brasil, dados referentes à biologia de F&SM restringem-se a testes de eficiência de fungicidas ou provêm de estudos com outros patossistemas. O objetivo deste trabalho foi o de elucidar aspectos epidemiológicos destas doenças, fornecendo as bases para o manejo integrado. Foram realizados estudos de disponibilidade, dinâmica e controle de inóculo, de análise de distribuição espacial, de modelagem do progresso temporal e uma avaliação de um modelo de previsão de F&SM na região Nordeste do Rio Grande do Sul. As pesquisas foram realizadas nos ciclos 2006/07 e 2007/08 em Vacaria-RS. Foi verificado que o inóculo de F&SM esteve disponível durante todo o período de formação dos frutos, sugerindo que ciclos secundários são responsáveis pelo incremento da doença. A incidência de F&SM apresentou relação positiva com a intensidade das chuvas (mm/chuva e mm/h), e com o somatório de horas de molhamento foliar (R2≥0,85; P<0,05), sendo que as primeiras infecções foram estabelecidas desde os 30 primeiros dias após a queda das pétalas. A utilização de oxicloreto de cobre (0,5%) e hidróxido de cobre (0,5%) no período dormente de macieiras ‘Pink Lady®’ reduziu os danos de F&SM no momento da colheita, com controle de 33% e 53%, respectivamente. O regime pluviométrico nos três meses que antecederam à colheita influenciou a incidência de F&SM sem, no entanto, afetar o padrão agregado destas doenças (D>1). O modelo monomolecular apresentou o melhor ajuste ao progresso temporal, com R*2>0,90 independentemente do ciclo ou tratamento. Aplicações de tiofanato metílico + captana seguindo o critério do sistema de alerta, em combinação com o uso de poda verde, possibilitou, no ciclo 2007/08, uma redução de 66% no número de aplicações com fungicidas, sem afetar o controle quando comparado aos tratamentos preventivos. / Apple production in Brazil is located at the southern states and comprises an area of around 35 thousand hectares. In spite of the advanced technology in use, crop physiological stresses and disease are responsible to severe economical losses, in which Sooty Blotch and Flyspeck (SBFS) are of secondary importance, among other diseases. Losses by SBFS are due to fruit blemishes that are caused by growth of the fungi on the apple cuticule. In Brazil, epidemiological knowledge on SBFS is very limited and restricted to fungicide testing studies. The aim of this work was to study key epidemiological aspects and management strategies for SBFS control at the conditions of northeastern production of Rio Grande do Sul State. Field experiments were conducted in 2006/07 and 2007/08 seasons at Vacaria, RS. A series of experiments were planned to study inoculum and infections dynamics driven by environmental conditions, disease reduction by winter treatments, disease spatial patterns and assessment of management strategies for disease control by evaluating usefulness of a warning system and effect of cultural practices and fungicide treatments. Disease incidence was observed in fruits exposed during all infection windows demonstrating inoculum availability during all fruits stages. Disease incidence showed a linear relationship with precipitation rates (mm/rain and mm/h) and leaf wetness duration (R²≥0,85; P=0,05) measured during each window. The use of cooper oxycloret (0,5%) or cooper hydroxid (0,5%) sprays during dormant stages allowed reduction of 33% and 53%, respectively, in the SBFS incidence at harvest. Spatial analysis using beta-nominal distribution and geoestatistics showed disease aggregation among samplins units, being stronger aggregated when decreasing the number of plants in the sampling units. The monomolecular model best described SBFS incidence temporal progress (R*²>0,90) regardless of the fungicides treatments or season. Fungicide applications with a mix of thiophanate-methyl and captana following a disease warning system, in association with summer pruning allowed reduction of 66% in the number of sprays when compared to preventive treatment with the same control efficiency.
46

Incidência de cancro cítrico (Xanthomonas citri pv. citri) em pomar de laranjeiras 'Valência' sob concentrações e freqüências de pulverizações cúpricas

Theisen, Sergiomar January 2004 (has links)
O objetivo deste trabalho foi de buscar alternativas para aumentar a eficiência do controle do cancro cítrico (Xanthomonas citri pv. citri) nos pomares do Rio Grande do Sul, avaliando o efeito de concentrações de três bactericidas cúpricos e de duas freqüências de pulverização nas fases de intensa brotação.
47

Validación de un método colorimétrico basado en nanopartículas de oro para la determinación de plomo (Pb+2) en muestras de agua para uso y consumo humano

Villanueva Villaueva, Miguel Omar 04 October 2018 (has links)
El plomo (Pb+2) es un contaminante ambiental de alto riesgo para la salud. La OMS establece un valor límite máximo permisible de plomo en el agua potable de 48.3 nM. En contraposición, la Autoridad Europea de Seguridad Alimentaria (EFSA) describe efectos nocivos en el desarrollo neurológico a niveles de 10.1 nM de plomo en agua para el consumo humano. En la industria de los laboratorios analíticos, la cuantificación de Pb+2 en agua para uso y consumo humano está dominada por métodos basados en AAS, ICP/MS y ICP/OES. Estas metodologías carecen de sensibilidad para los niveles de concentración descritos por la EFSA. La metodología propuesta se basa en un sensor químico a partir de nanopartículas de oro de 14 nm de diámetro funcionalizadas con ácido maleico, capaz de detectar y reconocer al Pb+2 en solución de manera específica y selectiva, mediante la alteración del plasmón de resonancia de superficie localizado de las nanopartículas de oro como señal analítica detectable mediante espectrofotometría UV-Vis. La calidad del agua puede ser controlada a través de la medición de contaminantes ambientales por métodos que deben pasar previamente por una validación metodológica para brindar confiabilidad en los resultados analíticos. Entonces, debe validarse el método evaluando el desempeño de la metodología y estimando la incertidumbre del resultado. La validación demuestra que el método es lineal en un rango de concentraciones de 2.30 a 100 nM de Pb+2 con un coeficiente de determinación (r2) de 0.9948. La estimación de los límites de detección y cuantificación son 0.70 nM y 2.30 nM respectivamente. El método es veraz, al obtener 101.0% de recuperación para niveles de Pb+2 de 10 nM. Los interferentes estudiados en este trabajo no son fuente de error para los límites máximos permisibles (LMP) para la matriz de agua de uso y consumo humano descritos por el Ministerio de Salud del Perú. / Tesis
48

Desarrollo y optimización de un sensor químico portátil basado en la transferencia de energía entre nanopartículas de oro y rodamina B como agente fluorescente para la determinación de cianuro (CN-) en soluciones acuosas

Veliz Portal, Lorena Amelia 04 October 2018 (has links)
El anión cianuro es un compuesto inorgánico que se origina de forma natural o antropogénica, y tiene la facilidad de transportarse largas distancias al estar presente, en pequeñas proporciones, dentro de las partículas de polvo que pueden desplazarse por el aire con facilidad. Este ion es altamente utilizado en la industria metalúrgica y en la extracción de oro y plata cuyos efluentes son luego desechados en las fuentes de agua más cercanas. En nuestro país existen innumerables mineras informales dedicadas a la extracción de oro utilizando cianuro. Estas empresas ponen en riesgo a las poblaciones y al medioambiente aledaño ya que no cuentan con medidas de seguridad y planes de contingencia, ni obedecen las regulaciones del estado. Hasta el día de hoy se han desarrollado numerosos métodos analíticos para la determinación de cianuro; sin embargo, la mayoría de ellos requieren largos tiempos de preparación de muestras y un análisis o instrumentación costosa. Frente a ello han surgido nuevas posibilidades para la detección del anión cianuro, entre ellos los ensayos colorimétricos y de fluorescencia basados en nanomateriales. Estos permiten una cuantificación con bajos límites de detección de manera rápida, precisa y con un tratamiento de muestra sencillo. En este trabajo se desarrolló y optimizó un nanosensor de nanopartículas de oro, caracterizadas por medio de las espectroscopía de UV-Vis y microscopía de fuerza atómica, basado en la transferencia de energía empleando un fluoróforo de bajo costo, la rodamina B, para la detección de cianuro. El sensor fue monitoreado por fluorescencia y demostró ser sensible y selectivo a cianuro obteniéndose un límite de detección de 2 μM. A su vez, el sensor se implementó en una plataforma portátil sin que esto comprometa la sensibilidad de su respuesta incluso en presencia de muestras de matrices complejas. / Tesis
49

Eficácia dos integradores químicos x indicadores biológicos no monitoramento dos ciclos de esterilização a vapor: revisão sistemática da literatura / Efficacy of chemical integrators x biological indicators in the monitoring of steam sterilization cycles: systematic review of literature

Martinho, Maria Antonieta Velosco 24 April 2007 (has links)
Este estudo trata-se de uma revisão sistemática cujo objetivo foi levantar as evidências na literatura científica da eficácia dos integradores químicos no monitoramento dos ciclos de esterilização a vapor. As estratégias de busca foram realizadas nas bases de dados MEDLINE, LILACS, CINAHL, DEDALUS, OVID, Cochrane e Google Acadêmico, através de combinações dos termos esterilização (sterilization), integrador químico (chemical integrator), indicador químico (chemical indicator), indicador biológico (biological indicator), monitoramento (monitoring) e reagente (reagent). Foi realizado ainda busca em árvore das referências dos artigos selecionados. Os estudos foram selecionados sem restrições quanta a data de publicação e a língua, com critérios de inclusão de estudos básicos experimentais comparativos quanto ao desempenho dos indicadores químicos frente a cinética de morte microbiana ou resultados obtidos por meio de indicadores biológicos em ciclos de esterilização a vapor e exclusão de estudos realizados com métodos de esterilização que não a vapor e estudos que evidenciam utilização de indicadores químicos classes 1, 2, 3 e 4. No total foram selecionados 7 estudos, sendo que o mais antigo data 1975 e o mais recente 2006, 6 destes estudos compararam indicadores químicos à indicadores biológicos e 1 estudo comparou indicadores químicos frente a curva da cinética de morte microbiana dos Bacillus stearothermophilus. Em relação à origem dos estudos 1 é europeu e 6 americanos, sendo 1 destes brasileiro. Para análise e avaliação dos estudos utilizou-se a seguinte categorização: escopo, tipo de estudo, unidades amostrais, amostra, esterilizador utilizado, procedimentos, análise dos dados, limitações, resultados, conclusões e comentários. Observou-se uma tendência de utilização de temperaturas de 132º e 121ºC para a realização dos experimentos. O tamanho amostral variou de 1 a 47 indicadores por ciclo e o número de ciclos reproduzidos de 1 a 12. Não houve uma tendência em relação aos esterilizadores utilizados e tempos de exposição adotados. 4 estudos utilizaram integradores químicos nos experimentos, sendo que 2 destes utilizaram indicadores não classificados, concomitantemente. Analisando os resultados dos estudos conclui-se que nenhum integradores classe 5 nem indicadores biológicos apresenta respostas 100% sensíveis ou 100% específicas quanto ao desempenho esperado e que Integradores químicos classe 5 e indicadores biológicos apresentam variações de sensibilidade e resistência muito próximos uns dos outros, não cabendo neste momento classificá-los numa escala de efetivos a não efetivos. Os resultados obtidos dos integradores classe 6 mostram 100% de viragem dentro do tempo estimado, sugerindo que estes integradores são efetivos para o monitoramento dos ciclos a vapor / This study is a systematic review, with the objective of collecting evidences in the scientific literature, on the efficacy of the chemical integrators in the monitoring of the steam sterilization cycles. The search strategies were carried out in the MEDLINE, LILACS, CINAHL, DEDALUS, OVID, Cochrane and Academic Google data bases, through the combination of the terms sterilization (esterilização), chemical integrator (integrador químico), chemical indicator (indicador químico), biological indicator (indicador biológico), monitoring (monitoramento), and reagent (reagente). A search in the references tree of the selected articles was also carried out. The studies were selected without restrictions concerning publication date and language, with inclusion criteria of basic experimental comparative studies as for the performance of chemical indicators concerning the kinetics of the microbial death or the results obtained by means of biological indicators in steam sterilization cycles and, the exclusion of studies carried out with non–steam sterilization methods and studies that show the use of chemical indicators classes 1, 2, 3 and 4. A total of 7 studies were selected, the oldest from 1975 and the most recent from 2006; 6 of these studies compared chemical indicators to biological indicators and 1 study compared chemical indicators facing the microbial death kinetics curve of the stearothermophilus Bacillus. In relation to the origin of the studies, 1 is European and 6 are American, 1 of them being Brazilian. For the analyses and assessment of the studies, the following categorization was used: purpose, kind of study, sample units, sample, sterilizer used, procedures, data analyses, limitations, results, conclusions and comments. It was observed a trend of utilization of temperatures between 132º and 121º Celsius for the carrying out of the experiments was observed. The sample size varied from 1 to 47 indicators per cycle and the number of cycles reproduced from 1 to 12. There was no trend concerning the sterilizers used and the exposure time periods adopted. Four studies used chemical integrators in the experiments, and 2 of them used non-classified indicators, concurrently. By analyzing the results of the studies, we came to the conclusion that neither class 5 integrators nor biological indicators present 100% sensitive or 100% specific answers, as for the expected performance, and the class 5 chemical integrators and the biological indicators present variations of sensibility and resistance very close to each other, thus, at the moment they should not be classified in a effective to non-effective scale. The results obtained from integrators class 6 show a 100% turning inside the estimated time, suggesting that these integrators are effective for the monitoring of the steam cycles
50

Aplicação de métodos multivariados para a análise e correlação de amostras apreendidas de cocaína

Grobério, Tatiane Souza 21 January 2017 (has links)
Tese (doutorado)—Universidade de Brasília, Instituto de Química, Programa de Pós-Graduação em Química, 2017. / Submitted by Raquel Almeida (raquel.df13@gmail.com) on 2017-05-10T19:26:20Z No. of bitstreams: 1 2017_TatianeSouzaGrobério.pdf: 7983031 bytes, checksum: 74fbf4855ae64c21f3c468efc2f13060 (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2017-05-25T23:06:06Z (GMT) No. of bitstreams: 1 2017_TatianeSouzaGrobério.pdf: 7983031 bytes, checksum: 74fbf4855ae64c21f3c468efc2f13060 (MD5) / Made available in DSpace on 2017-05-25T23:06:06Z (GMT). No. of bitstreams: 1 2017_TatianeSouzaGrobério.pdf: 7983031 bytes, checksum: 74fbf4855ae64c21f3c468efc2f13060 (MD5) Previous issue date: 2017-05-25 / É sabido que o abuso de drogas ilícitas constitui um problema social sério e de difícil solução. Dentre as drogas de abuso, a cocaína tem ocupado papel de destaque. A fim de tentar controlar e reduzir a disponibilidade da cocaína no mercado ilícito, diversos organismos de segurança pública nacionais e internacionais buscam estratégias para estabelecer a origem, principais métodos de refino e rotas mais comuns do tráfico de drogas. Tais objetivos podem ser alcançados por meio de investigações policiais e quimicamente através de análises que caracterizem a droga. A caracterização de uma amostra de cocaína é o processo que determina as suas principais propriedades físicas e químicas, revelando similaridades e diferenças entre apreensões. Neste trabalho, a caracterização química da amostra iniciou-se pela determinação da forma de apresentação da cocaína (sal ou base livre), do teor de cocaína, adulterantes e identificação do grau de oxidação em amostras de drogas utilizando espectroscopia de infravermelho por transformada de Fourier com acessório de reflexão total atenuada (FTIR-ATR, do inglês Fourier Transform Infrared Spectroscopy – Attenuated Total Reflectance), que é uma técnica mais simples, rápida, com maior facilidade de aplicação e menor custos que cromatografia gasosa, técnica utilizada em métodos de referência atualmente utilizado pela Polícia Federal Brasileira (PF). Esse método foi desenvolvido e validado com 1085 amostras reais de drogas apreendidas pela PF em todo o Brasil, das quais 500 foram selecionadas para o conjunto de calibração e 585 para o conjunto de validação para uma análise multivariada de regressão por mínimos quadrados parciais (PLSR, do inglês Partial Least Squares Regression). Obteve-se um erro médio de previsão de 3,0% (m/m), precisão de 2,0 e concentração mínima detectável de cocaína de 11,8% (m/m), em uma faixa de concentração variando de 24,2 a 99,9% (m/m). Os resultados indicaram que o método desenvolvido é capaz de discriminar entre o cloridrato de cocaína e as amostras de base livre, quantificar o conteúdo de cocaína e estimar a concentração dos principais adulterantes. Em uma segunda fase do trabalho, a caracterização química das amostras foi utilizada para identificar correlações entre apreensões de cocaína base livre sem o conhecimento a priori sobre a origem das amostras. Para isso, buscou-se determinar os solventes residuais com o uso do headspace associado à cromatografia gasosa e detecção por espectrometria de massas (HS-CG-EM). A análise de dados empregou a análise hierárquica de agrupamento (HCA, do inglês Hierarchical Cluster Analysis) e o quadrado da função cosseno. Estudos estatísticos apontaram valores limites que puderam III discriminar amostras como sendo “ligadas”, ou seja, correlacionadas em relação à forma de produção, permitindo estabelecer ligações entre apreensões de cocaína efetuadas em todo o Brasil. A metodologia desenvolvida para essa discriminação pôde ser considerada promissora, pois não necessita do conhecimento a priori da população de amostras e permite o ajuste dinâmico dos valores limites para diferentes conjuntos. / It is known that illicit drug abuse is a social problem and difficult to solve. Among the drugs of abuse, a cocaine has played a prominent role. In order to try to control and reduce the availability of cocaine in the illicit market, various public and international security agencies are looking for strategies to establish an origin, main refining methods and most common routes of drug trafficking. Such objectives can be seen through software investigations and analyze the aspects that characterize the drug. The characterization of a cocaine sample is the process that determines its main physical and chemical properties, revealing similarities and differences between seizures. In this work, the chemical characterization of the sample was initiated by determining the form of presentation of cocaine (salt or free base), cocaine content, adulterants and identification of the degree of oxidation in drug samples using infrared spectroscopy (FTIR-ATR), which is a simpler, faster, easier to apply and lower cost than gas chromatography, a technique used in reference methods currently used by the Brazilian Federal Police (BPF). This method was developed and validated with 1085 real drug samples seized by PF throughout Brazil, of which 500 were selected for the calibration set and 585 for the validation set for a multivariate analysis of partial least squares regression (PLSR). An average prediction error of 3.0% (w/w), precision of 2.0 and minimum detectable concentration of cocaine of 11.8% (w/w) was obtained in a concentration range ranging from 24.2 to 99.9% (w/w). The results indicated that the method was able to discriminate between cocaine hydrochloride and free base samples, to quantify the cocaine content and to estimate the concentration of the main adulterants. In a second phase of the study, the chemical characterization of the samples was used to identify correlations between free base cocaine seizures without a priori knowledge about the origin of the samples. The aim of this study was to determine residual solvents using headspace associated with gas chromatography and mass spectrometry detection (HS-CG-EM). The data analysis employed the hierarchical cluster analysis (HCA) and the square of the cosine function. Statistical studies pointed to limit values that could discriminate samples as being "linked", that is, correlated in relation to the form of production, allowing establishing links between seizures of cocaine made throughout Brazil. The methodology developed for this discrimination could be considered promising since it does not require a priori knowledge of the population of samples and allows the dynamic adjustment of the limit values for different sets of samples.

Page generated in 0.0606 seconds