• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 234
  • 9
  • Tagged with
  • 244
  • 244
  • 188
  • 182
  • 154
  • 82
  • 79
  • 75
  • 70
  • 62
  • 54
  • 54
  • 47
  • 46
  • 44
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Análise de variações topológicas aplicadas a uma UPS tipo delta monofásica

Ghetti, Frederico Toledo 26 May 2009 (has links)
Submitted by isabela.moljf@hotmail.com (isabela.moljf@hotmail.com) on 2017-03-02T11:39:15Z No. of bitstreams: 1 fredericotoledoghetti.pdf: 2816885 bytes, checksum: 98c4c49d919a94d51a94ff86a91c33a1 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-03-06T19:32:09Z (GMT) No. of bitstreams: 1 fredericotoledoghetti.pdf: 2816885 bytes, checksum: 98c4c49d919a94d51a94ff86a91c33a1 (MD5) / Made available in DSpace on 2017-03-06T19:32:09Z (GMT). No. of bitstreams: 1 fredericotoledoghetti.pdf: 2816885 bytes, checksum: 98c4c49d919a94d51a94ff86a91c33a1 (MD5) Previous issue date: 2009-05-26 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / É apresentado, neste trabalho, um estudo sobre topologias alternativas de fontes ininterruptas de energia do tipo Delta, para o emprego em cargas monofásicas de até 1kVA. O estudo prevê a inserção de um conversor CC-CC entre o conversor shunt e o banco de baterias. Tal modificação em relação à UPS do tipo Delta convencional otimiza o projeto do banco de baterias e requisita um menor número de células em série para sua confecção. Além disso, a proposta elimina o uso de transformadores de baixa freqüência, considerados em alguns trabalhos anteriores, o que também contribui para a redução do peso e volume do sistema. Duas diferentes topologias para o conversor CC-CC foram investigadas e comparações de desempenho e viabilidade foram realizadas. A topologia que apresentou melhor desempenho nos quesitos custo, volume e peso, foi selecionada para testes em bancada. Ao final, resultados simulados e práticos são apresentados para validação do modelo. / This dissertation presents a study on single-phase Delta-UPS topological alternatives for low power and low cost applications. The proposed topology has a DC-DC converter connected between the shunt inverter and the battery bank/series converter DC terminals, respectively. This modification will allow the downsizing of the DC battery bank as well as the removing of the series converter transformer. Two different topologies of the DC DC converter were investigated and a comparative study among them will be accomplished. Simulation results are presented and experimental results will be included to validate the proposed study.
172

Controle de um filtro ativo de potência bifásico a três fios utilizando a teoria p-q monofásica

Furtado, Pablo Carlos de Siqueira 27 June 2014 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-04-24T20:26:56Z No. of bitstreams: 1 pablocarlosdesiqueirafurtado.pdf: 4055605 bytes, checksum: b23cd5bfadf3eb9e69e3e5e804322231 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-04-25T15:21:49Z (GMT) No. of bitstreams: 1 pablocarlosdesiqueirafurtado.pdf: 4055605 bytes, checksum: b23cd5bfadf3eb9e69e3e5e804322231 (MD5) / Made available in DSpace on 2017-04-25T15:21:49Z (GMT). No. of bitstreams: 1 pablocarlosdesiqueirafurtado.pdf: 4055605 bytes, checksum: b23cd5bfadf3eb9e69e3e5e804322231 (MD5) Previous issue date: 2014-06-27 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Esta dissertação apresenta uma estratégia para controlar um filtro ativo de potência (FAP) paralelo bifásico a três fios. A aplicação desse FAP pode ser implementada como uma funcionalidade extra do conversor fonte de tensão do sistema de propulsão de veículos elétricos (VE), o que seria útil para compensar instalações elétricas residenciais e comerciais com fornecimento de energia bifásico a três fios. Apresenta-se o princípio de funcionamento do FAP bifásico e é tratada sua modelagem matemática. É feita uma revisão dos conceitos de potências instantâneas p e q em sistemas monofásicos, a chamada teoria p–q monofásica. É mostrada ainda a interpretação dessas grandezas e sua relação com as potências ativa e reativa convencionais. Em seguida, são feitas adaptações na implementação dessa teoria. A principal adaptação está na forma de implementar as transformações αβ monofásicas. Com essas adaptações, a teoria p–q modificada é utilizada para descrever o algoritmo de controle desenvolvido para o FAP bifásico. A estratégia de compensação adotada consiste na compensação de todas as componentes harmônicas de corrente, da potência reativa e na equalização das correntes nas fases envolvidas. São apresentados resultados obtidos em estudos de simulação da operação do FAP bifásico em regime permanente e sob transitórios das cargas. O trabalho mostra ainda alguns resultados experimentais do FAP em operação. Conclui-se que os resultados obtidos validam o princípio de operação do FAP bifásico e a estratégia de controle proposta. / This thesis presents an strategy to control a two–phase, three-wire shunt active power filter (APF). This APF can be implemented as an extra functionality of the embedded voltage source converter in the propulsion system of an electric vehicle (EV). This application would be useful in the compensation of residential and commercial electrical installations fed by a two–phase three–wire grid connection. The working principle of shunt two-phase APF is presented and its mathematical models are also treated. Concepts of the instantaneous powers p and q, called single-phase p–q theory, are reviewed. The relationship between these quantities and the conventional active and reactive powers is discussed. Then, some adaptations are done in the implementation of such theory. The main one is related to the implementation method of singlephase αβ transformations. After these adaptations, the modified p–q theory is used to described the developed algorithm to control the two–phase APF. The adopted control strategy consists of compensating all current harmonics and reactive power, as well as equalizing currents in involved phases. Simulation results are presented to show the APF operation in steady-state and under load changes. Yet, some experimental results are presented to show the APF in operation. The obtained results validate the presented working principle and the control strategy proposed in this thesis.
173

Sistema inteligente para monitoração, gerenciamento e controle de iluminação pública e análise de parâmetros da rede elétrica

Pinto, Milena Faria 22 June 2015 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-01-07T18:22:40Z No. of bitstreams: 1 milenafariapinto.pdf: 3767169 bytes, checksum: 1c057d68b3cee498c456fe7c7610b2c2 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-01-25T16:53:33Z (GMT) No. of bitstreams: 1 milenafariapinto.pdf: 3767169 bytes, checksum: 1c057d68b3cee498c456fe7c7610b2c2 (MD5) / Made available in DSpace on 2016-01-25T16:53:33Z (GMT). No. of bitstreams: 1 milenafariapinto.pdf: 3767169 bytes, checksum: 1c057d68b3cee498c456fe7c7610b2c2 (MD5) Previous issue date: 2015-06-22 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O presente trabalho propõe um sistema eletrônico que permite gerenciar, monitorar parâmetros e controlar de forma descentralizada um conjunto de luminárias à LED pertencentes a um sistema de iluminação pública. Estes parâmetros incluem nível de iluminação, consumo de energia, detecção da presença de pedestres, problemas na própria luminária e monitoração de variáveis ambientais como temperatura e umidade. Adicionalmente, o mesmo sistema é capaz também de detectar falhas na rede elétrica, permitindo monitorar e gerenciar os parâmetros de qualidade de rede de uma forma global. Basicamente, o sistema pode ser dividido em três partes. A primeira parte consiste de um módulo inteligente, chamado neste trabalho por SM, que é conectado a uma determinada luminária e à rede elétrica, sendo assim responsável por medir tanto os parâmetros provindos da luminária quanto da rede elétrica. Na segunda parte encontra-se o módulo controlador (CM) que possui a finalidade de coordenar as informações oriundas dos módulos inteligentes instalados nas luminárias, armazenando e posteriormente enviando os dados para um sistema supervisório. Além disso, o mesmo possui sensores de temperatura e umidade para prover informações sobre as condições climáticas, objetivando confiabilidade nos dados medidos pelos sensores dos módulos inteligentes. O sistema supervisório (SS) consiste da etapa final deste sistema proposto, o qual é responsável por salvar os dados obtidos em um certo período de tempo, analisar e monitorar possíveis falhas e enviar comandos para cada CM e/ou um respectivo SM. Com a finalidade de avaliar experimentalmente o sistema proposto neste trabalho, foram realizados experimentos para demonstrar tanto as funcionalidades do módulo bem como da avaliação dos algoritmos de processamento de sinais propostos, e obtendo ao final projeções econômicas para o protótipo. Os resultados obtidos mostraram eficiência, flexibilidade e interoperabilidade do sistema proposto. / The present paper proposes a system to manage, control and monitor a group of LED luminaires of a street lighting system, being able to control the light intensity of the luminaire and monitoring the power consumption, detection of pedestrians, fault conditions, environmental parameters such as temperature and humidity. Additionally, the system contains a voltage sensor coupled to the grid in order to monitor and manage the power quality parameters. Basically, the system can be divided in three essential parts. The first one regards the smart module, called in this work as SM, which has the responsibility to sensing the parameters stemming from power grid as well as luminaire. The second part is the control module (CM), which has the aim to coordinate the data received from each smart module, storing and subsequently sending the data to the supervisory system. Besides, the control module also has temperature and humidity sensors in order to check and register environmental conditions, providing, in this way, reliability of the measured data. The supervisory system (SS) consists of the final part of the proposed system and it is responsible to save the data in a local memory, to analyze and to monitor problems or even possible faults and sending commands to each CM and/or a respective SM. With the aim to evaluate the proposed system, it was performed experiments to demonstrate the system operation as well as the quality analysis capability. Due to the energy savings potential provided by the technology, it was also studied the economic feasibility of the prototype, aiming a future commercial product. The results have shown that the proposed system is scalable, flexible and efficient.
174

Metodologia para a monitoração eficiente de variações de tensão de curta duração em sistemas elétricos de potência. / Methodology for monitoring voltage SAGs and SWELLs in power systems.

Carlos Frederico Meschini Almeida 14 February 2007 (has links)
Esta dissertação apresenta uma metodologia baseada em Algoritmos Genéticos e Teoria dos Conjuntos Fuzzy que determina o número ótimo de medidores de Qualidade de Energia, bem como os pontos onde os mesmos devem ser instalados para monitorar Afundamentos e Elevações de Tensão em redes de transmissão de energia elétrica. A metodologia desenvolvida representa uma ferramenta para diversas áreas de uma empresa de energia elétrica, porque ela indica a melhor maneira para se alocar medidores de Qualidade de Energia, considerando as restrições econômicas a que as empresas estão sujeitas. Além disto, a metodologia também determina a melhor configuração para um sistema de medição para um sistema de potência, quando há barras que devem ser monitoradas e/ou o número de medidores disponíveis é menor que o mínimo necessário para atingir a completa Observabilidade. O trabalho desenvolvido também representa uma importante aplicação dos Algoritmos Genéticos em conjunto com a Teoria dos Conjuntos Fuzzy. Ele define aspectos a serem considerados no problema de monitoração de Qualidade de Energia Elétrica e sugere rapidamente a melhor forma de atender diferentes objetivos e restrições operacionais. A fim de validar o modelo proposto, nesta dissertação, três redes elétricas são avaliadas para determinar o número mínimo de medidores de Qualidade de Energia, bem como a localização onde esses equipamentos deveriam ser instalados. Os níveis de Redundância e de Observabilidade são apresentados, bem como as formulações usadas para atingir os resultados apresentados. / This dissertation presents a methodology based on Genetic Algorithms and Fuzzy Mathematical Programming to determine the optimum number of power quality monitors and the locations they should be installed to measure Voltage Sags and Swells in transmission power networks. The methodology developed represents a tool for planning power networks, because it indicates the best way to allocate the power quality monitors, considering economical constraints. Similar to this, the methodology also determines the best configuration for a monitoring system when there are important busses to monitor and the number of monitors available is lower than the minimal needed to accomplish completely Observability. The work presented here also represents an important Genetic Algorithms application. With fuzzy mathematical programming it easily allows the definition of aspects to be considered in the monitoring problem and quickly suggests the best way to attend different objectives and operational restrictions. In order to validate the developed model proposed in this dissertation three electric power networks are assessed to determine the minimum number of power quality monitors as well as the locations where these devices should be installed. The levels of Redundancy and Observability are presented as well as the formulations used to achieve the results.
175

Avaliação de aspectos da instalação de geração distribuída fotovoltaica em unidades sujeitas a cobrança de reativos no Brasil /

Castro Júnior, Wanderley Araújo de January 2020 (has links)
Orientador: Júlio Borges de Souza / Resumo: Este trabalho apresenta uma avaliação dos aspectos da instalação de sistemas de geração distribuída fotovoltaica (GDFV) em unidades consumidoras sujeitas à cobrança de reativos no Brasil. A avaliação dos possíveis impactos técnicos e financeiro é realizada sob o alicerce da legislação e normativas aplicáveis. São abordados os modos de medição, sistema tarifário aplicado à unidade em estudo, bem como um comparativo com outros tipos de unidades consumidoras com geração distribuída (GD). São realizadas projeções de funcionamento em condições definidas, faz-se uso do equacionamento definido pela legislação e normas vigentes. Também é realizado um estudo de caso em uma unidade consumidora real. Como resultado apresentam-se gráficos que ilustram o comportamento da curva de geração fotovoltaica, consumo demandado, consumo medido, bem como o comportamento do fator de potência em unidades com GDFV instalada. Isto viabiliza a aferição de eventuais pontos positivos e negativos da instalação de GD nesse tipo de unidade consumidora. No estudo de caso também são apresentadas, em forma de tabela, os valores e percentuais de economia da unidade, comparando com o período sem GDFV. Por fim, são avaliados os possíveis impactos no tempo de retorno do investimento, contribuições negativas na qualidade de energia do sistema elétrico e apresentadas propostas de soluções para sanar ou atenuar os problemas encontrados. / Abstract: This paper presents an evaluation of the aspects of the installation of photovoltaic distributed generation systems in consumer units subjected to reactive charging in Brazil. The assessment of possible technical and financial impacts is carried out on the basis of applicable legislation and regulations. Measurement modes are addressed, the tariff system applied to the unit studied, a comparison is made with other types of consumer units with distributed generation (DG). Operating projections are carried out under defined conditions, using the equation defined by current legislation and standards. A case study is also performed in a real consumer unit. As a result we present graphs that illustrate the behavior of the photovoltaic generation curve, demanded consumption, measured consumption, as well as the behavior of the power factor in units with installed photovoltaic distributed generation system. This makes it possible to measure any positive and negative points of the installation of DG in this type of consumer unit. In the case study are also presented in table form the values and percentages of economy of the unit, comparing with the period without distributed photovoltaic generation. Finally, the possible impacts on return on investment time, negative contributions on the electric power quality of the electric system are evaluated and proposals of solutions to solve or mitigate the problems are presented. / Mestre
176

Conversor multifuncional conectado à rede elétrica para compensação de oscilações de potência instantânea /

Olímpio Filho, José de Arimatéia January 2019 (has links)
Orientador: Helmo Kelis Morales Paredes / Resumo: Esta dissertação de mestrado propõe o desenvolvimento e a implementação de uma estratégia de compensação para conversores eletrônicos de potência (CEP) multifuncionais conectados à rede elétrica. A geração dos sinais de referência de corrente para o conversor multifuncional é obtida através das grandezas conservativas da CPT, do inglês Conservative Power Theory. O CEP proposto neste trabalho desempenha o papel de um conversor interface de rede no modo conectado, tendo como finalidade a mitigação de oscilações de potência instantânea bem como injeção de potência ativa na rede elétrica, caracterizando assim o seu aspecto multifuncional. São realizados estudos teóricos e simulações computacionais com o intuito de validar a estratégia proposta. Para tanto, foram identificadas as parcelas indesejadas de corrente que permitam a compensação das componentes oscilatórias da potência instantânea e da energia reativa instantânea da CPT. O CEP é controlado em modo corrente, através da estratégia de modulação PWM com duas malhas de controle. A estratégia de compensação e o sistema de controle serão avaliados e testados via simulação para diferentes configurações de cargas, incluindo uma carga não-linear desbalanceada operando em condições onde as distorções e desequilíbrios de tensão sejam consideráveis. Por fim, resultados experimentais obtidos com um protótipo em escala laboratorial são utilizados para validar a estratégia de compensação proposta / Abstract: This master’s thesis proposes the development and implementation of a compensation strategy for the three-phase multifunctional grid-tied inverter. The reference signal generation method for grid-tied is based on the Conservative Power Theory (CPT). In this work, the multifunctional inverter plays the role of the Utility Interface (UI) which perform several functions: in grid-connected operation, it injects active power into the grid and compensates the instantaneous power oscillation and the instantaneous reactive energy oscillation. The goal is to execute theoretical studies and computational simulations to validate the proposed strategy. For this purpose, firstly are identifies the unwanted currents which allow the compensation of the oscillatory terms of instantaneous power and reactive energy. The inverter is controlled in current mode through PWM modulation strategy with two control loops. In addition, the proposed compensation strategy and control system is evaluated and tested for different load configurations, such as linear and nonlinear loads (balanced and unbalanced) operating under different voltage conditions (distorted and unbalanced). Finally, experimental results are presented to validate the effectiveness and performance of the proposed compensation strategy. / Mestre
177

Mitigação de variações de tensão causadas pela proteção anti-ilhamento de geradores distribuídos via controle de taps de reguladores de tensão / Mitigating voltage variations caused by the anti-islanding protection of distributed generator via voltage regulator tap control

Lima, Daniel Ferreira 04 August 2017 (has links)
A conexão de geradores distribuídos em sistemas de distribuição deve ser cuidadosamente avaliada para que os mesmos auxiliem efetivamente na melhoria do desempenho das redes elétricas, buscando reduzir ou eliminar eventuais situações que causem a degradação da qualidade da energia elétrica fornecida aos consumidores, entre outros aspectos. Neste contexto, existem vários trabalhos que analisam a influência da conexão de geradores distribuídos no perfil de tensão da rede elétrica, frequência, desequilíbrio de fases e distorção harmônica. No entanto, há poucos trabalhos analisando os efeitos da desconexão de geradores distribuídos na qualidade da energia fornecida aos consumidores. Uma vez operando em paralelo com a rede de distribuição, esses geradores influenciam o perfil de tensão e o comportamento dos dispositivos reguladores de tensão. Como consequência, sua desconexão pode provocar variações de tensão intensas causando danos ou mau funcionamento às cargas. A desconexão pode ser repentina ou devido à atuação da proteção anti-ilhamento, seguida dos procedimentos de religamento automático do alimentador, se houver. Visando estudar este problema, o qual tende a se tornar uma nova preocupação das concessionárias de energia elétrica, e no intuito de minimizar e/ou eliminar os possíveis efeitos negativos dessas variações de tensão, esta pesquisa propõe o desenvolvimento de um método de controle dos taps dos reguladores de tensão. Neste método, o controle dos taps foi modelado como um problema de otimização, minimizando as violações de tensão mencionadas anteriormente e também a quantidade de operações dos reguladores de tensão ao longo de um dia típico. A otimização foi solucionada com um Algoritmo Genético e os resultados obtidos indicaram que é possível minimizar as variações de tensão usando a curva de carga do sistema para planejar a operação dos reguladores de tensão. / The connection of distributed generators in an electric power system should be evaluated carefully to ensure that they effectively assist in improving the performance of electrical networks, reducing or eliminating any situations that cause degradation of the power quality of the consumers, and other issues. In this context, there are several studies that analyze the influence of generators connected to distribution systems and how they affect the frequency, cause variations in voltage magnitude, voltage unbalance and harmonic distortion. However, there are a few studies analyzing the effects that the disconnection of distributed generators induces to the power quality of consumers. Once operating in parallel with the distribution network, these generators have an effect on voltage variations and voltage regulator devices. As a result, disconnection can cause severe voltage variations causing damage or malfunction to the loads. The disconnection may be sudden or due to the action of anti-islanding protection, followed by the procedure to reconnect the substation, if it is possible. In order to study this problem, which tends to become a new power quality concern for electric utilities, and in order to minimize and / or eliminate the possible side effects of the voltage variations, this research proposes the development of a control method of voltage regulators\' taps. In this method, the control of taps was modeled as an optimization problem which aimed to minimize these voltage variations aforementioned and also the amount of voltage regulator operations over a typical day. The optimization was solved by a Genetic Algorithm and the results obtained demonstrate that it is possible to minimize the voltage variation by using the system load curve to plan the operation of voltage regulators.
178

Metodologia para diagnóstico e análise da influência dos afundamentos e interrupções de tensão nos motores de indução trifásicos / Methodology for the diagnosis and analysis of influence of voltage sags and interruptions in three-phase induction motors

Gibelli, Gerson Bessa 20 May 2016 (has links)
Nesta pesquisa, é proposta uma metodologia para detectar e classificar os distúrbios observados em um Sistema Elétrico Industrial (SEI), além de estimar de forma não intrusiva, o torque eletromagnético e a velocidade associada ao Motor de Indução Trifásico (MIT) em análise. A metodologia proposta está baseada na utilização da Transformada Wavelet (TW) para a detecção e a localização no tempo dos afundamentos e interrupções de tensão, e na aplicação da Função Densidade de Probabilidade (FDP) e Correlação Cruzada (CC) para a classificação dos eventos. Após o processo de classificação dos eventos, a metodologia como implementada proporciona a estimação do torque eletromagnético e a velocidade do MIT por meio das tensões e correntes trifásicas via Redes Neurais Artificiais (RNAs). As simulações computacionais necessárias sobre um sistema industrial real, assim como a modelagem do MIT, foram realizadas utilizando-se do software DIgSILENT PowerFactory. Cabe adiantar que a lógica responsável pela detecção e a localização no tempo detectou corretamente 93,4% das situações avaliadas. Com relação a classificação dos distúrbios, o índice refletiu 100% de acerto das situações avaliadas. As RNAs associadas à estimação do torque eletromagnético e à velocidade no eixo do MIT apresentaram um desvio padrão máximo de 1,68 p.u. e 0,02 p.u., respectivamente. / This study proposes a methodology to detect and classify the disturbances observed in an Industrial Electric System (IES), in addition to, non-intrusively, estimate the electromagnetic torque and speed associated with the Three-Phase Induction Motor (TPIM) under analysis. The proposed methodology is based on the use of the Wavelet Transform WT) for the detection and location in time of voltage sags and interruptions, and on the application of the Probability Density Function (PDF) and Cross Correlation (CC) for the classification of events. After the process of events classification, the methodology, as implemented, provides the estimation of the electromagnetic torque and the TPIM speed through the three-phase voltages and currents via Artificial Neural Networks (ANN). The necessary computer simulations of a real industrial system, as well as the modeling of the TPIM, were performed by using the DIgSILENT PowerFactory software. The logic responsible for the detection and location in time correctly detected 93.4% of the assessed situations. Regarding the classification of disturbances, the index reflected 100% accuracy of the assessed situations. The ANN associated with the estimation of the electromagnetic torque and speed at the TPIM shaft showed a maximum standard deviation of 1.68 p.u. and 0.02 p.u., respectively.
179

Determinação do conteúdo harmônico de corrente baseada em redes neurais artificiais para cargas não-lineares monofásicas / Determination of the current harmonic content based on artificial neural networks for single-phase non-linear loads

Nascimento, Claudionor Francisco do 10 July 2007 (has links)
Este trabalho apresenta um método utilizando redes neurais artificiais para a determinação das amplitudes e fases dos componentes harmônicos presentes na corrente de carga monofásica. O número de harmônicos identificados é previamente selecionado. Os hamônicos identificados estão presentes na corrente de cargas não-lineares de um sistema de iluminação onde é considerada a variação no tempo das características da forma de onda desta corrente. Os harmônicos presentes no sistema degradam a qualidade de energia, sendo assim é apresentado um breve estudo sobre este tema e métodos para atenuar a distorção harmônica no sistema. Dentre estes métodos é dado ênfase na aplicação de filtros ativos de potência em paralelo com carga não-linear. O trabalho também apresenta um estudo sobre os mais comumente métodos utilizados na identificação harmônica. Dentre eles está o método baseado em redes neurais artificiais. Este método é validado com base nos dados levantados por meio de simulação e de forma experimental. / In this thesis artificial neural networks are employed in a novel approach to identifying harmonic components of the single-phase nonlinear load current, whose amplitudes and phase angles are subject to unpredictable changes in steady-state. An identified harmonics number is previously selected. These harmonics are present in the non-linear loads current of electrical illumination system. The harmonics in the power system degrade the power quality, then is exhibited a concise study dealing with power quality problems and methods to mitigate the harmonic distortion in the power system. Among these methods emphasis is given in the application of pure active power filters in parallel with the non-linear load. The thesis also shows a study about the more commonly methods used in the harmonic detection. Among them is the method based on artificial neural networks. Simulation and experimental results are presented to validate the proposed approach.
180

Identificação de faltas de alta impedância em redes aéreas multiaterradas. / Identification of high impedance faults in overhead multi grounded networks.

Arias, Juan Camilo Garcia 12 December 2014 (has links)
As faltas de alta impedância (FAI) ocorrem quando um condutor entra em contato com objetos com uma alta resistência, o que não resulta em incrementos significativos de corrente. Este tipo de falta não pode ser detectada por dispositivos de proteção tradicionais que atuam por sobrecorrente. Neste trabalho uma pesquisa do estado da arte das FAI é apresentada e são implementados alguns algoritmos de detecção presentes na literatura. Nesta pesquisa também são propostas duas metodologias de identificação de FAI as quais são baseadas na identificação de buildup e incrementos de energias na faixa de frequências 1920Hz a 3840Hz. Os algoritmos implementados e as metodologias propostas foram testados com simulações de eventos de FAI e de eventos comuns numa rede simulada de uma concessionária do Estado de São Paulo utilizando o software ATP. Estudos do funcionamento de um medidor de qualidade de energia foram feitos com o propósito de determinar as limitações de uma eventual implementação real das metodologias de identificação propostas neste trabalho. Resultados do desempenho das metodologias propostas utilizando os sinais simulados em ATP apresentaram percentagens de identificação superiores aos 80%. Análise das ocorrências de cabo rompido do circuito em estudo foram feitas com o propósito de identificar possíveis eventos de FAI. O desempenho apresentado pelas metodologias propostas na identificação de FAI em sinais reais pode ser melhorado com a disponibilidade de uma maior quantidade de eventos reais de FAI. / High impedance faults (HIF) occur when a conductor makes contact with high resistance objects, generally not resulting in significant current increases. This type of fault cannot be detected by traditional overcurrent protection devices. In this work, a research of the HIF state-of-art is presented and some detection algorithms in the literature are implemented. This research also proposes two HIF identification methods based on respectively the identification of buildup current and energy increments in the frequency range from 1920Hz to 3840Hz. The implemented algorithms and the proposed methodology have been tested with ATP simulations of FAI events and other common events in a simulated network from an electric utility in the State of Sao Paulo. Studies are carried out in order to assess the operation of a power quality meter to determine the limitations of real implementations of the proposed methodologies. Performance results of the proposed methodologies using simulated ATP signals show identifications rates greater than 80%. Broken conductor occurrences in the studied feeder are analyzed to identify possible HIF events. The performance shown by the proposed methodologies in identifying HIF in real situations can be improved with the availability of a larger number of HIF events.

Page generated in 0.0831 seconds