• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 198
  • 123
  • 42
  • 24
  • 24
  • 6
  • 6
  • 5
  • 4
  • 3
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 513
  • 251
  • 68
  • 67
  • 46
  • 45
  • 44
  • 42
  • 37
  • 34
  • 34
  • 33
  • 33
  • 32
  • 30
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

Avaliação de contaminação com óleo diesel por meio dos métodos de Eletrorresistividade e Polarização Induzida em Santa Ernestina-SP / Evaluation of an oil contaminated area in Santa Ernestina (São Paulo) using DC Resistivity and IP methods

Veloso, Dimitri Ilich Kerbauy [UNESP] 20 April 2016 (has links)
Submitted by DIMITRI ILICH KERBAUY VELOSO null (dimitriveloso@hotmail.com) on 2016-05-03T21:03:36Z No. of bitstreams: 1 Dissertação Final.pdf: 8318470 bytes, checksum: 1f59566750ab6e5e25d4b72baa3db621 (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-05-06T13:58:33Z (GMT) No. of bitstreams: 1 veloso_dik_me_rcla.pdf: 8318470 bytes, checksum: 1f59566750ab6e5e25d4b72baa3db621 (MD5) / Made available in DSpace on 2016-05-06T13:58:33Z (GMT). No. of bitstreams: 1 veloso_dik_me_rcla.pdf: 8318470 bytes, checksum: 1f59566750ab6e5e25d4b72baa3db621 (MD5) Previous issue date: 2016-04-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A contaminação de solos e águas subterrâneas pode colocar em risco a saúde humana além de inviabilizar a exploração de recursos naturais por longos períodos, com sérios prejuízos ambientais, administrativos e financeiros. Este trabalho realizou um estudo em área contaminada no município de Santa Ernestina-SP, com o intuito de avaliar o atual cenário de contaminação deste local por meio da investigação geofísica pelos métodos de Eletrorresistividade e Polarização Induzida. A área foi contaminada em 2007 devido a um acidente ferroviário que causou o derramamento de 58000 litros de óleo diesel. O monitoramento da área foi realizado durante os quatro anos subsequentes ao acidente, a partir de sondagens manuais a trado, poços de monitoramento, coleta de amostras de água subterrânea e levantamento de dados geológicos e hidrogeológicos, integrados em sucessivos relatórios disponibilizados na Agência Ambiental (CETESB) de Araraquara-SP. A escolha dos métodos de Eletrorresistividade e Polarização Induzida foi feita com o objetivo de analisar as relações de contrastes entre as propriedades elétricas do meio subsuperficial e dos contaminantes em solo e água subterrânea. Foram realizadas 11 linhas paralelas de imageamento elétrico em arranjo Wenner, com geração de modelos de inversão geofísica 2D na forma de seções de resistividade e cargabilidade, e modelos integrados de visualização 3D, a partir dos quais foram gerados mapas de profundidade (horizontes de 1m, 3m, 5m e 7m). Os resultados de resistividade elétrica indicaram zonas rasas de baixa resistividade (valores em torno de 150Ω.m) que ocorrem de forma restrita, próximas aos principais locais de infiltração de contaminantes. Esta assinatura geofísica foi correlacionada à presença de resquícios de contaminantes em zona insaturada, onde os processos de atenuação natural conduziram à queda da resistividade do meio geológico a partir da diluição e dissolução de compostos orgânicos e iônicos. Os resultados para cargabilidade viabilizaram um novo ponto de vista investigativo sobre o monitoramento de áreas contaminadas. Por meio destes dados, foi possível associar a ocorrência de biodegradação à provável presença de minerais metálicos neoformados (sulfetos e óxidos) durante e após a ação dos processos de atenuação natural. A formação destes minerais deve estar associada principalmente à alteração das condições físico-químicas do ambiente geológico e à disponibilidade de íons em solos tropicais contaminados por hidrocarbonetos, tais como Fe+3 e, principalmente, S-2 . O conjunto dos resultados aponta para um panorama geral de avançado estágio de descontaminação da área, com atuação efetiva dos processos de atenuação natural, decorridos sete anos do acidente. / Soil and groundwater contamination presents hazards for human health and can spoiling natural resources for long time giving serious environmental, administrative and financial damages. This paper carried out a study in a contaminated area in Santa Ernestina-SP, in order to evaluate the present scenery of contamination by geophysical methods of DC Resistivity and Induced Polarization methods. The contamination site is due to a railway accident ocurred in 2007 that spilled 58.000 liters of diesel. Since the accident, site monitoring had been done during four years and comprised manual probing, monitoring wells, groundwater samples and geological and hydrogeological data, integrated in successive reports provided by the Environmental Agency (CETESB/ Araraquara - SP). Geophysical methods of DC Resistivity and Induced Polarization were used to detect contrasts in physical properties and its connection with soil and groundwater contamination. It was carried out an electrical imaging that consisted in 11 parallel lines organized in Wenner array. This acquisition allowed generating 2D inversion models for electrical resistivity and chargeability, in addiction to an integrated 3D display model for each parameters, that allowed generating depth maps (1m, 3m , 5m and 7m horizons). The electrical resistivity results indicated low resistivity shallow zones (values around 150Ω.m) that occurs confined, near the sites of contaminant infiltration. This geophysical signature was correlated to traces of contaminants presents into the unsaturated zone, which natural attenuation process led to reduction of the environmental resistivity due to dilution and dissolution of organic and ionic compounds. The chargeability results had enabled a new side of investigation related to the monitoring of contaminated sites. Through this data, it was possible to link the occurrence of biodegradation to likely presence of metallic minerals neoformation (sulfides and oxides) during and after the natural attenuation activity. Minerals neoformation is propably associated with changes in physicochemical environmental‟s conditions in addict to availability of ions (Fe+3 and, mainly, S-2 ) in tropical contaminated soils.The results‟overview suggests an advanced decontamination stage of the site, for which one the natural attenuation processes has been effective more than seven years since the accident.
192

RESISTIVIDADE ELÉTRICA DE CONCRETOS COM DIFERENTES TEORES DE ESCÓRIA DE ALTO FORNO E ATIVADOR QUIMICO / ELECTRICAL RESISTIVITY IN CONCRETE WITH DIFFERENT CONCENTRATIONS OF BLAST FURNACE SLAG AND A CHEMICAL ACTIVATOR

Rosa, Dalton Wegner da 15 December 2005 (has links)
The integrity of the rebars in reinforced concrete structures is related to the chemical and physical protection provided by the concrete layer that covers the steel. The destruction of the passivation layer precedes the onset of corrosion. Once the corrosion process starts, its rate of propagation will depend on the electrical resistivity between cathode and anode and the amount of oxygen available on the cathode. Concrete resistivity is a property linked both to the chemical and physical properties of the concrete. This study investigated the effect of the addition of blast furnace slag (BFS) on the electrical resistivity of concrete and correlated the effects of this addition on the concrete compressive strength as well as on changes in the chemical composition of aqueous phase and pore structure. Test specimens were prepared using different water/binder ratios (0.35, 0.50 and 0.65) and substitutions of 50 and 70% of BFS for cement by weight. A control sample (no BFS) was also prepared. Additionally, the effect of 4% sodium sulfate (Na2SO4) in samples with 50% BFS was also investigated. The electrical resistivity of concrete was determined using the fourelectrode method (Wenner s method adapted for use in concrete). Tests of compressive strength, porosimetry, electrical conductivity in the pore solution and the concentration of ions in the aqueous phase were performed. The tests showed there is an increase in the electrical resistivity of concrete as the degree of hydration and the concentration of BFS increase. This is related to the lower specific conductivity of the pore solution and the reduction in concrete pore size, which is shown by the good correlation between these two factors. The binary mixture with 50% BFS (50E) showed the best cost/benefit ratio for strength levels of 30MPa and 50MPa at 28 days and also for the strength level of 50MPa at 91 days. / A manutenção da integridade das armaduras nas estruturas de concreto é uma conseqüência da proteção física e química do concreto sobre o aço. A destruição da camada passivadora antecede o processo corrosivo. Uma vez iniciada a corrosão, a velocidade desta dependerá da resistividade elétrica existente entre o ânodo e o cátodo e também pela quantia de oxigênio presentes junto ao cátodo. A resistividade do concreto caracteriza-se por ser uma propriedade ligada tanto a características físicas como químicas do mesmo. Neste trabalho objetivou-se estudar o comportamento da adição de escória de alto forno na resistividade elétrica aparente dos concretos, assim como correlacionar com a resistência à compressão e as alterações químicas na fase aquosa bem como na estrutura dos poros. Foram realizadas investigações em misturas com relação a/agl 0,35, 0,50 e 0,65 com teores de substituição em massa de 0, 50 e 70% de EAF. Investigou-se também os efeitos produzidos pela incorporação de 4% de sulfato de sódio (Na2SO4) em misturas contendo 50% de EAF. A resistividade elétrica do concreto foi determinada utilizando o método dos quatro eletrodos (método de Wenner adaptado para uso em concreto). Foram também realizados ensaios de resistência à compressão axial, porosimetria, concentração de íons da fase aquosa e determinada a condutividade elétrica específica da solução dos poros. Constatou-se aumento na resistividade elétrica do concreto com o aumento no grau de hidratação e do teor de escória. Este comportamento está relacionado a menor condutividade elétrica específica da solução dos poros e ao refinamento dos poros comprovado pela boa correlação entre esses dois fatores. A mistura binária composta por 50% de escória (50E) apresentou a melhor relação custo/benefício para os níveis de resistência de 30MPa e 50MPa aos 28 dias e também para o nível de resistência de 50MPa aos 91 dias.
193

Aplicação do método eletromagnético transiente em área contaminada sob atenuação natural

Moreira, César Augusto [UNESP] 13 October 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-10-13Bitstream added on 2014-06-13T20:54:12Z : No. of bitstreams: 1 moreira_ca_me_rcla.pdf: 8326908 bytes, checksum: aabce1d39adb0817d36429889d591481 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Este trabalho discute a aplicabilidade do método geofísico Eletromagnético Transiente (TEM) a partir de análise comparativa com o método de Eletrorresistividade, em uma área industrial contaminada por derivados de petróleo e atualmente sob processos de Atenuação Natural. Dentre os contaminantes presentes no solo e água subterrânea estão o Benzeno, Tolueno, Xileno, 1,2 Dicloroetano, Sódio, Cloreto e Sulfato. A remediação da área é realizada exclusivamente por Atenuação Natural, ou seja, ação de processos físicos, químicos e biológicos responsáveis pela degradação, dispersão e diluição dos contaminantes. Foram utilizadas as técnicas de sondagem eletromagnética de loop central, caminhamento eletromagnético, sondagem elétrica vertical e caminhamento elétrico. Os resultados apresentam uma anomalia de baixa resistividade adjacente aos poços de injeção, e anomalias de alta resistividade sob estes poços. A grande área abrangida pela anomalia de baixa resistividade é fruto principalmente da biodegradação dos contaminantes de fase líquida leve não aquosa - LNAPL, cujas sucessivas quebras em compostos mais simples por ação de microorganismos resulta em ácidos orgânicos que corroem grãos minerais, que são liberados ao meio sob a forma iônica. A pequena área abrangida pela anomalia de alta resistividade é produto da concentração de contaminantes pouco degradados, caracterizados por elevada resistividade em relação á água. O TEM se mostrou aplicável no estudo de áreas contaminadas e o processo de Atenuação Natural está sendo eficaz na remediação da área. / This work discuss the applicability of the Transient Electromagnetic Method (TEM) from comparative analysis with the Electrical Method, in an industrial area contaminated by oil derived and currently under processes of Natural Attenuation. Amongst the contaminants presents in the soil and groundwater they are the Benzene, Toluene, Xylene, 1,2 Dichloroetene, Sodium, Chloride and Sulphate. A remediation of the area is carried through exclusively by Natural Attenuation, or either, action of physical, chemical and biological processes responsible for the degradation, dispersion and dilution of contaminants. The techniques of electromagnetic sounding of central loop, electromagnetic tomography, vertical electric sounding and electric tomography had been used. The results present an anomaly of low adjacent resistivity to the injection wells, and anomalies of high resistivity under these wells. The great area enclosed for the anomaly of low resistivity is fruit mainly of the biodegradation of the contaminants of light non-aqueous phase liquid - LNAPL, whose successive breakings in simpler composites for action of microorganisms result in acid organic that corrode mineral grains, that are set free to the way under the ionic form. The small area enclosed for the anomaly of high resistivity is product of the concentration of contaminants little degraded, characterized for raised resistivity in relation a water. The TEM if it showed applicable in the study of contaminated areas and the process of Natural Attenuation is being efficient in the remediation of the area.
194

Estudo geofísico em sedimentos contaminados por etanol (álcool combustível) em escala de laboratório

Castello, Leonardo Zani [UNESP] 19 April 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:11Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-04-19Bitstream added on 2014-06-13T20:33:56Z : No. of bitstreams: 1 castello_lz_me_rcla.pdf: 3708951 bytes, checksum: 0a40d517edbecb13c7bec61c650816dd (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Estudos ambientais envolvendo investigação e mapeamento do meio geológico por meio de métodos geoelétricos apresentam resultados satisfatórios para contaminantes iônicos (chorume) que sugerem eficácia no emprego desses métodos em situações que apresentem alterações dos componentes do subsolo devido à presença de combustíveis, como o etanol. Integrando a aplicação dos métodos geofísicos da eletrorresistividade, polarização induzida e potencial espontâneo, por meio das técnicas de caminhamento elétrico e perfilagem elétrica foi monitorada a variação temporal dos parâmetros físicos resistividade, cargabilidade elétrica e potencial espontâneo em sedimentos arenosos alterados devido à contaminação controlada de etanol, contidos em um tanque de monitoramento. O tanque de monitoramento contém um sistema de controle do nível de saturação, possibilitando análises das variações nos parâmetros geoelétricos investigados em dois extratos geoelétricos: insaturado e saturado. O presente trabalho objetiva avaliar o comportamento do etanol num experimento que simula condições hidrogeológicas reais, bem como caracterizar as variações temporais nos parâmetros geoelétricos analisados. Este tipo de pesquisa objetiva também a geração de subsídios técnico/científico que auxiliem a compreensão de estudos de caso em ambientes naturais / Environmental studies involving research and mapping of geological environment by geoelectrical methods present satisfactory results for ionic contaminants (leachate) that suggest effectiveness in their use in situations that present changes in components of the basement due to the presence of fuels such as ethanol. Integrating the application of geophysical methods of resistivity, induced polarization and spontaneous potential, through the techniques of electrical profiling and electrical profiling was monitored temporal variation of physical parameters, resistivity, chargeability and electrical spontaneous potential in sandy sediments changed due to contamination of controlled ethanol contained in a tank monitoring. The tank contains a monitoring system to control the saturation level, allowing analysis of variations in geoelectrical parameters investigated in two extracts geoelectrical: unsaturated and saturated. This study aims to evaluate the behavior of ethanol in an experiment that simulates actual hydrogeological conditions and to characterize temporal variations in geoelectrical parameters analyzed. This type of research also aims to generate subsidies technical / scientific understanding to help the case studies in natural environments
195

Geofísica aplicada no monitoramento de área de disposição de resíduos sólidos domiciliares

Moreira, César Augusto [UNESP] 24 April 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:17Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-04-24Bitstream added on 2014-06-13T20:43:11Z : No. of bitstreams: 1 moreira_ca_dr_rcla.pdf: 2315680 bytes, checksum: 0c4f65c2b2bcf53160a74f7b3683d14b (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho realiza um monitoramento em uma área de disposição de resíduos sólidos, para análise do comportamento temporal dos materiais enterrados e verificação da hipótese de aplicação e uso dos métodos geofísicos em estudos que prevejam o término na geração de chorume em aterros. Foram medidos os parâmetros físicos: resistividade elétrica, cargabilidade e potencial elétrico natural, a partir dos métodos geofísicos de Eletrorresistividade, Polarização Induzida e Potencial Espontâneo, por meio da técnica de caminhamento elétrico e de sondagem elétrica vertical. Também foram realizadas medidas de pH, Eh, ensaios de peneiramento, análise granulométrica e permeabilidade hidráulica de campo. Foi investigado o Aterro Controlado Municipal de Cordeirópolis (SP), uma área de disposição de resíduos sólidos domiciliares em valas escavadas no solo, com datas de abertura e fechamento programadas. A aquisição de dados consistiu na seleção de valas anualmente fechadas entre 12/2001 e 12/2007, realização dos ensaios geofísicos e coleta de solo para medidas de pH e Eh. Houve um aumento do potencial espontâneo das valas recentes para as valas antigas, possivelmente associado à estabilidade geoquímica crescente ao longo do período de degradação dos resíduos orgânicos. Há uma correlação entre baixa resistividade e alta cargabilidade em áreas ricas em matéria orgânica, enquanto que áreas com escassez de matéria orgânica são caracterizadas por baixos valores de cargabilidade e de resistividade. Também há uma correlação entre anomalias de baixo potencial espontâneo e de alta cargabilidade. A variação relativa dos parâmetros para cada vala, associados ao tempo de residência dos materiais, permitiu relacioná-los às fases de degradação de matéria orgânica em aterros. A análise estatística dos valores indica ser necessário 8 anos para... / This work accomplishes a monitoring in solid waste landfill, for analysis of the temporary behavior of the buried materials and verification of the application hypothesis and use of the geophysical methods in studies that foresee the end in the leachate generation in landfill. They were measured the physical parameters: electric resistivity, chargeability and natural electric potential, starting from the geophysical methods of Electrical Resistivity, Induced Polarization and Spontaneous Potential, through the techniques of electric profiling and vertical electric sounding. Were also accomplished pH and Eh measures, sieving, granulates analysis and hydraulic permeability field. The Cordeirópolis Solids Waste Landfill was investigated, a disposition area of domiciliary residues in ditches dug in the soil, with opening and closing programmed dates. The data acquisition consisted in annually selection of ditches closed between 12/2001 and 12/2007, accomplishment of the geophysical survey and soil collection for pH and Eh measures. There was an increase of the spontaneous potential of the recent ditches for the old ditches, possibly associated to the geochemical stability growing along the period of degradation of the organic residues. There is a correlation between low resistivity and high chargeability in rich areas in organic matter, while areas with shortage of organic matter are characterized by low chargeability values and of low resistivity. There is also a correlation among anomalies of low spontaneous potential and high chargeability. The relative variation of the parameters for each ditch, associated to residence time of the materials, allowed relating them the phases of degradation of organic matter in landfills. The statistical analysis of the values indicates to be necessary 8 years for return to the natural resistivity values of the rock located to 10m of depth and 12 years... (Complete abstract click electronic access below)
196

Early-age mechanical properties and electrical resistivity of geopolymer composites

Safari, Samira January 2016 (has links)
Cement-less and/cement-like geopolymer mortars were made with pulverised fuel ash (PFA) or ground granulated blast furnace slag (GGBS) activated by alkali with different alkali moduli (AM) and alkali dosage (AD). Once synthesised the samples were cured at 20°C and 70°C up to 28 days. The flexural and compressive strengths of these samples at early ages up to 28 days were tested conforming to BS EN196-1:2005. The electrical resistivity of these materials was monitored using a set of non-contacting electrodes to the age up to 7 days to characterise the geopolymerisation process from a physical phenomenon point of view. The effects of AD and AM on the early-age mechanical strengths and electrical resistivity of geopolymer materials were examined from the experimental results. The correlation between strength development and electrical resistivity was studied. The geopolymerisation process was characterised by a 5-stage model, based on electrical resistivity, analogue to hydration process of Portland cement. This research therefore proposes an alternative method for characterisation of geopolymerisation of geopolymers different from traditional methods based on chemistry. It is expected that such a physical phenomenon model will be better accepted by structural engineers for better promotion of usage of geopolymer composites, a type of low carbon and more sustainable binder-based materials, in construction.
197

Tomografia elétrica aplicada na investigação de fluxo de lixiviado em meio fraturado em um lixão no município de Lavras do Sul (RS) / Electrical resistivity tomography applied in the investigation of leachate flow in a fractured environment in a dump in the city of Lavras do Sul (RS)

Santos, Rodolfo Busolin Alves dos 06 February 2018 (has links)
Submitted by RODOLFO BUSOLIN ALVES DOS SANTOS null (rodolfo_busolin@hotmail.com) on 2018-03-27T01:32:36Z No. of bitstreams: 1 Dissertação.pdf: 7973963 bytes, checksum: 2e90678c451c6ded29475c9bcd42029c (MD5) / Approved for entry into archive by Ana Paula Santulo Custódio de Medeiros null (asantulo@rc.unesp.br) on 2018-03-27T12:27:06Z (GMT) No. of bitstreams: 1 santos_rba_me_rcla.pdf: 7696907 bytes, checksum: b5a23c52c7fbb3f6024f32da8c4b4dcc (MD5) / Made available in DSpace on 2018-03-27T12:27:06Z (GMT). No. of bitstreams: 1 santos_rba_me_rcla.pdf: 7696907 bytes, checksum: b5a23c52c7fbb3f6024f32da8c4b4dcc (MD5) Previous issue date: 2018-02-06 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A área de estudo está localizada na cidade de Lavras do Sul – RS, que é uma antiga pedreira que foi reaproveitada para a deposição dos resíduos oriundo do município. O objetivo principal é realizar o detalhamento geofísico e estrutural da contaminação do antigo lixão e correlacionar a percolação do lixiviado com as zonas fraturadas, com o uso de dois métodos de investigação (Eletrorresistividade e Polarização Induzida) e os dois arranjos (Dipolo-Dipolo e Schlumberger). Foram realizados 12 perfis de resistividade e cargabilidade na direção 45ºN, processados em 2D e 3D, e foi determinado uma possível presença de zonas de contaminação e percolação de lixiviado para fora da área do lixão. Também foi possível determinar onde estavam dispostos os resíduos sólidos e os limites do lixão, zonas fraturadas com a presença de lixiviado e zonas fraturadas com a presença de sulfetos que aprofundam até 36 m. Desde o início da operação do lixão a contaminação atingiu diversos metros de profundidade, porém com o tempo e a atenuação natural, essas zonas de fratura fecharam devido a cristalização de sulfeto. Os dois arranjos apresentaram resultados satisfatórios para os valores de resistividade. Com relação aos valores de cargabilidade, o arranjo Schlumberger apresentou melhores resultados do que o Dipolo-Dipolo. A geofísica demonstrou ser uma ferramenta importante no estudo de contaminações em rochas cristalinas, principalmente pela sua capacidade de detecção de fraturas e sua profundidade atingida. / The study area is located in the city of Lavras do Sul - RS, which is an old quarry that was reused for the deposition of waste from the municipality. The main objective is to perform the geophysical and structural detailing of the contamination of the old dump and to correlate the percolation of the leachate with the fractured zones, using the two research methods (DC Resistivity and Induced Polarization) and the two arrangements (Dipole-dipole and Schlumberger). By performing 12 profiles of resistivity and chargeability in the 45ºN direction, processed in 2D and 3D, a possible presence of contamination zones and percolation of leachate outside the dump area was determined. It was also possible to determine where the solid wastes and the boundaries of the dump were located, fractured zones with the presence of leachate and fracture zones with the presence of sulfides that deepen up to 36 m. From the beginning of the operation of the dump the contamination reached several meters deep, but with time and the natural attenuation, these zones of fracture closed due to mineral neoformation of sulfide. Both arrangements presented satisfactory results for the resistivity values, in relation to the chargeability values, the Schlumberger arrangement presented better results than the Dipole-Dipole. Geophysics has been shown to be an important tool in the study of contaminations in crystalline rocks, mainly due to its ability to detect fractures and its depth.
198

Caracterização geofísica de contaminação por hidrocarbonetos em acidente ferroviário no município de Botucatu - SP / Geophysical characterization of hydrocarbon contamination in a railway accident in municipality of Botucatu (SP)

Cavallari, Fernanda [UNESP] 27 March 2017 (has links)
Submitted by Fernanda Cavallari null (fee.cavallari@gmail.com) on 2017-05-18T02:01:15Z No. of bitstreams: 1 cavallari_f_me_rcla.pdf: 4868463 bytes, checksum: f8aa337d6db1b37fa37f09ef94076c5f (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-05-19T12:47:13Z (GMT) No. of bitstreams: 1 cavallari_f_me_rcla.pdf: 4868463 bytes, checksum: f8aa337d6db1b37fa37f09ef94076c5f (MD5) / Made available in DSpace on 2017-05-19T12:47:13Z (GMT). No. of bitstreams: 1 cavallari_f_me_rcla.pdf: 4868463 bytes, checksum: f8aa337d6db1b37fa37f09ef94076c5f (MD5) Previous issue date: 2017-03-27 / O diagnóstico de áreas contaminadas é um procedimento obrigatório ao tratamento e remediação de solo e águas subterrâneas. Contaminantes complexos como hidrocarbonetos passam por transformações físicas e químicas ao longo do tempo de permanência no ambiente geológico, com alterações no grau de dissolução no sistema aquífero. Este trabalho descreve a aplicação de métodos geofísicos integrados com um histórico de dados químicos, numa área contaminada por hidrocarbonetos vazados num acidente ferroviário, em 2005, na zona rural do município de Botucatu (SP). Foram utilizados os métodos geofísicos Eletrorresistividade e Polarização Induzida, por meio de 5 linhas paralelas de tomografia elétrica em arranjo Schlumberger, programadas e posicionadas a partir da interpretação de um histórico de análises geoquímicas do solo e água subterrânea. Os dados de tomografia elétrica permitiram a geração de modelos de inversão 2D e modelos de visualização 3D. De forma geral, o histórico de análises geoquímicas, última atualização em 2007, indica claramente a redução de teores de contaminantes em solo e no aquífero. A análise integrada de dados indica o avançado estado de degradação dos hidrocarbonetos, reconhecido por elevados valores de alta cargabilidade em relação ao padrão natural da área, concomitantemente a zonas de média resistividade. As áreas contaminadas e monitoradas por análise químicas foram caracterizadas por alta cargabilidade e média resistividade, com indícios de neoformação pretérita de sulfetos e condições próximas as do ambiente geológico natural, ou seja, indícios de processo avançado de atenuação natural e quase desaparecimento dos contaminantes. / The diagnosis of contaminated areas is a mandatory procedure to treatment and remediation of soil and groundwater. Complex contaminants like hydrocarbons undergo physical and chemical changes along the dwell time in the geological environment, with changes in dissolution and spread in unsaturated and saturated soil aquifer system. This research describes the application of geophysical methods integrated with a history of chemical data in a contaminated area by leaked hydrocarborn in a railway accident, in 2005, at rural area in Botucatu (SP). The geophysical methods Electrical Resistivity and Induced Polarization were used by 5 parallel lines of electrical resistivity tomography in Schlumberger array, programmed and adjusted from a history of chemical analysis of groundwater. The electrical tomography data allowed the generation of 2D inversion models and visualization of 3D models. In general, the history of geochemical analysis, last updated in 2007, clearly indicates a reduction of contaminant levels in soil and in the aquifer. The data integrated analysis indicated the advanced state of degradation of hydrocarbons, recognized by high values of high chargeability in relation to the natural pattern of the area, concomitantly to areas of medium resistivity. The areas contaminated and monitored by chemical analysis were characterized by high chargeability and medium resistivity, with indications of past formation of sulfides and conditions close to the natural geological environment, that is, indications of advanced process of natural attenuation and near disappearance of the contaminants.
199

Modelo conceitual de circulação de água subterrânea em aquífero cristalino no município de Itu/SP / Conceptual model of groundwater circulation in crystalline aquifer in the municipality of Itu/SP

Engelbrecht, Bruno Zanon [UNESP] 03 April 2017 (has links)
Submitted by BRUNO ZANON ENGELBRECHT null (bruno_zenon2@hotmail.com) on 2017-05-29T15:14:19Z No. of bitstreams: 1 engelbrecht_bz_me_rcla.pdf: 5854576 bytes, checksum: c42f1bd84eff53bf59926b2392253d96 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-05-31T16:34:17Z (GMT) No. of bitstreams: 1 engelbrecht_bz_me_rcla.pdf: 5854576 bytes, checksum: c42f1bd84eff53bf59926b2392253d96 (MD5) / Made available in DSpace on 2017-05-31T16:34:17Z (GMT). No. of bitstreams: 1 engelbrecht_bz_me_rcla.pdf: 5854576 bytes, checksum: c42f1bd84eff53bf59926b2392253d96 (MD5) Previous issue date: 2017-04-03 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O sistema aquífero cristalino estende-se por cerca de 62.000 km² no estado de São Paulo, correpondendo a aproximadamente 25% de sua área. A prospecção desses aquíferos, contudo, baseia-se majoritariamente na delimitação de feições lineares nas unidades geológicas e sua correlação com a evolução tectônica regional. Modelos hidrogeológicos conceituais proporcionam a compreensão dos mecanismos que governam a circulação e o armazenamento de água em subsuperfície, permitindo aprimorar e subsidiar a prospecção e gestão dos recursos hídricos subterrâneos. Com este objetivo, o presente estudo apresenta um modelo hidrogeológico conceitual do aquífero cristalino no município de Itu (SP), fundamentado em levantamentos por imageamento elétrico e valores de permeabilidade da zona não-saturada, bem como em análises químicas e isotópicas, tendo como principal enfoque a porção rasa do aquífero e suas interações com as águas superficiais. O modelo embute a ocorrência do manto de alteração e as descontinuidades do maciço rochoso na avaliação do potencial hídrico, prevendo expressiva conectividade hidráulica entre os compartimentos hidráulicos do manto de alteração e do embasamento cristalino fraturado. Os resultados obtidos mostram que a presença de depósitos sedimentares recentes e a ação de processos intempéricos, que resultam em horizontes porosos e na abertura de estruturas preexistentes, favorecem a infiltração, ocorrência e circulação de água em subsuperfície. As características mineralógicas e geométricas do manto de alteração, sua extensão e continuidade regional, redundam em aquíferos heterogêneos e complexos. A constante renovação das águas subterrâneas e sua conectividade com águas superficiais proporcionam a captação das águas de aquíferos cristalinos como fonte hídrica complementar para o abastecimento público, desde que sejam apropriadamente estudadas e geridas. / In São Paulo state the crystalline aquifer system occupies about 62,000 km², corresponding to approximately 25% of its area. However, the prospection of these aquifers is based on the delimitation of linear features in the geological units and their correlation with the regional tectonic evolution. Conceptual hydrogeological models provide an understanding of the mechanisms that govern the circulation and storage of groundwater, allowing to improve and subsidize the exploration and management of groundwater resources. For this purpose, this study presents a conceptual hydrogeological model of the crystalline aquifer in the city of Itu (SP), based on electrical imaging surveys and permeability values of the unsaturated zone, as well as chemical and isotopic analyzes focused on the shallow portion of the aquifer and its interactions with surface water. The hydrogeological model incorporates the occurrence of the weathered zone and the discontinuities of the rock mass in the evaluation of the hydraulic potential, predicting expressive hydraulic connectivity between the hydraulic compartments of the alteration mantle and the fractured crystalline basement. The results show that the presence of recent sedimentary deposits and the processes, which result in porous horizons and the opening of preexisting structures, favor the infiltration, occurrence and circulation of subsurface water. The mineralogical and geometric characteristics of the weathered zone, its extension and regional continuity, results in heterogeneous and complex aquifers. The constant renewal of groundwater and its connectivity with surface water provides the usage of groundwater as a complementary water source for public supply, provided that they are properly studied and managed.
200

Caracterização de ocorrência de cobre por meio de levantamento estrutural e geofísico em faixa de dobramentos na região de Caçapava do Sul (RS) / Geoelectric prospection of copper occurrence in folding layers in the sul-riograndense shield (Brazil)

Santos, Shaiely Fernandes dos [UNESP] 23 June 2017 (has links)
Submitted by SHAIELY FERNANDES DOS SANTOS null (fer.shay@gmail.com) on 2017-07-04T16:04:57Z No. of bitstreams: 1 Dissertação Final_corrigida.pdf: 6609770 bytes, checksum: cf68b44bd226d8bbeb5bf8ce1f2066e6 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-07-04T18:34:07Z (GMT) No. of bitstreams: 1 santos_sf_me_rcla.pdf: 6609770 bytes, checksum: cf68b44bd226d8bbeb5bf8ce1f2066e6 (MD5) / Made available in DSpace on 2017-07-04T18:34:07Z (GMT). No. of bitstreams: 1 santos_sf_me_rcla.pdf: 6609770 bytes, checksum: cf68b44bd226d8bbeb5bf8ce1f2066e6 (MD5) Previous issue date: 2017-06-23 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A ampla variedade de aplicações de cobre estimula a exploração de áreas mineralizadas. A prospecção de sulfetos por meio de métodos geofísicos, como a Eletrorresistividade e a Polarização Induzida (IP), são altamente promissores devido ao contraste de resistividade elétrica e cargabilidade, onde depósitos com sulfetos disseminados ou filoneanos são caracterizados por baixa resistividade e alta polarizabilidade. Esse trabalho realizou estudo de prospecção geofísica por meio de aquisição tomográfica em ocorrência mineral de cobre, na região de Caçapava do Sul (RS). Foram realizadas três linhas de aquisição por meio da técnica de tomografia elétrica em arranjos Dipolo-dipolo, Schlumberger e Wenner com 400 metros de comprimento e 5 metros de espaçamento entre eletrodos, dispostas de forma perpendicular à estruturação geral da área, representada com um grande sinclinal, de alta complexidade geológica e estrutural, em cuja crista foram reconhecidas galerias de pesquisa com carbonatos e sulfetos de cobre. Os resultados indicam que o arranjo dipolo-dipolo melhor realça e detalha as feições em regiões com estruturas inclinadas e fraturas. Os modelos de inversão 2D e modelamento 3D apresentam regiões centrais e laterais com alta resistividade e alta cargabilidade com indicativo de provável zona de stockwork com sulfetos alojados. Zonas periféricas com moderada resistividade e moderada cargabilidade inferem possíveis áreas com presença de argilização, zonas com alta cargabilidade e baixa resistividade são prováveis zonas de sulfetação e as possíveis zonas de silicificação com altos valores de resistividade e baixos de cargabilidade, observadas nas adjacências das prováveis zonas mineralizadas. / The wide variety of copper applications encourages the exploration of mineralized areas. Sulfide prospecting by means of geophysical methods, such as electrical resistivity and induced polarization (IP), are highly promising due to the contrast of electrical resistivity and chargeability, where deposits with disseminated sulfides or filoneans are characterized by low resistivity and high polarizability. This work carried out a study of geophysical prospecting by means of tomographic acquisition in mineral copper occurrence, in the region of Caçapava do Sul (RS). Three acquisition lines were performed by means of electrical tomography technique using a Dipole-dipole, Schlumberger and Wenner arrangements, with a length of 400 meters and a spacing of 5 meters between the electrodes, arranged in perpendicular layout to the general structure of the area, represented by a large synclinal, of high geological and structural complexity, where research galleries with carbonates and copper sulfides were recognized in the ridge. The results indicate that the dipole-dipole arrangement best highlights and details features in regions with sloped structures and fractures. The 2D inversion models and 3D modeling indicate central and lateral regions with high resistivity and high chargeability with indicative of probable stockwork zone with housed sulfides. Peripheral zones with moderate resistivity and moderate chargeability infer possible areas with presence of argilization, zones with high chargeability and low resistivity are likely to be zones of sulfation and possible silicification zones with high resistivity values and low chargeability values, observed in the vicinity of the probable mineralized zones.

Page generated in 0.0289 seconds