• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 990
  • 28
  • 27
  • 27
  • 27
  • 13
  • 12
  • 12
  • 12
  • 10
  • 5
  • 4
  • 4
  • 3
  • 2
  • Tagged with
  • 1016
  • 409
  • 178
  • 172
  • 156
  • 143
  • 141
  • 137
  • 132
  • 124
  • 121
  • 120
  • 114
  • 110
  • 98
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
231

Comparação da odontometria pelos metodos eletronico, radiografico convencional e digital

Ferreira, Ricardo, 1965- 13 December 2000 (has links)
Orientador: Agenor Montebello Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T14:24:33Z (GMT). No. of bitstreams: 1 Ferreira_Ricardo_M.pdf: 2991673 bytes, checksum: 36aaecaed2a92023e7ce19c3f8238bba (MD5) Previous issue date: 2000 / Resumo: A determinação do correto comprimento de trabalho é de primordial importância para a terapia endodôntica. O método mais utilizado para este fim é o radiográfico. O propósito deste estudo foi o de comparar a eficácia de três métodos: método radiográfico convencional (filme Ektaspeed Plus marca KODAK), método radiográfico digital (DenOptix) e o método eletrônico (Iocalizador apical Apit) na determinação do comprimento de trabalho para endodontia nos elementos dentais de humanos in vitm. Foi constituída uma amostra de 90 dentes unirradiculares permanentes humanos extraídos, (30 incisivos inferiores, 30 caninos e 30 pré-molares inferiores). Uma lima K n° 15 foi introduzida no canal até que o aparelho eletrônico (Apit) sinalizasse que estava na constrição apical, o instrumento foi fixado nesta posição por meio de um cursor de borracha e adesivo a base de cianocrilato. Colocou-se o dente no respectivo alvéolo de uma secção de mandíbula com os tecidos moles, a fim de simular radiograficamente uma imagem de situação clínica. Duas radiografias para cada espécime foram tomadas, ambas pela técnica do paralelismo (cone longo, distância foco-filme de 40 cm) com aparelho de raios X em 70 Kv e 10 mA com tempo de exposição em 0,2 segundo, uma com o filme e outra com o sensor digital. Tomaram-se as medidas com o auxílio de lupa esteriomicroscópica. Os dados foram avaliados estatisticamente através do teste quiquadrado. Os resultados mostraram que não houve diferença estatisticamente significativa entre os três métodos de odontometria pesquisados para os três grupos de dentes. O método eletrônico, Apit, apresentou um índice médio de acerto de 88,9%, o método radiográfico convencional e o digital, de 95,5%. Os três métodos de odontometria obtiveram um alto índice de acerto, sendo assim todos considerados confiáveis / Abstract: The establishment of the correct working length is essential in endodontic therapy. The most used method for this purpose is the radiographic one. The aim of this in vitro study was to compare the effectiveness of three methods - conventional radiographic method (Kodak Ektaspeed plus film), digital radiographic method (DenOptix) and electronic method (Apit apex locator) - used in the establishment of the working length of human dental elements for endodontic therapy. The sample consisted of 90 extracted uniradicular permanent human teeth (30 inferior incisors, 30 canines and 30 inferior premolars). A 15 K file was introduced in the canal until the electronic apparatus (Apit) signaled that the apical constriction was reached. The file was fixed at this position using a rubber pointer and cyanocrylate-based adhesive. The tooth was then placed in its respective alveolus of a mandibular section with soft tissue in arder to simulate clinical image. Two radiographs of each specimen were taken, both using the parallelism technique (Iong cone, distance focus-film 40cm) with X-Ray apparatus of 70 Kv and 10 mA and 0,2 s exposure, one using film and the other using digital sensor. Data was statistically assessed using the chi-square test. The results did not show any statistically significant difference among the three methods studied for the tooth types used. The Apit electronic method showed an average index of accuracy of 88.9%, and the index of the remaining ones was 95.5%. Ali three methods showed a high accuracy index, thus being considered reliable / Mestrado / Mestre em Radiologia Odontológica
232

Estudo comparativo entre dois metodos de estimativa da maturação ossea

Araujo, Tasso Schusterschitz da Silva 03 July 2001 (has links)
Orientador: Francisco Haiter Neto / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T22:38:56Z (GMT). No. of bitstreams: 1 Araujo_TassoSchusterschitzdaSilva_M.pdf: 5400109 bytes, checksum: a2944cfc9a9bffc2493b41555a604137 (MD5) Previous issue date: 2001 / Resumo: O objetivo do presente trabalho foi avaliar a aplicabilidade e a confiabilidade de dois métodos de estimativa de maturação óssea, utilizando-se de uma amostra de crianças brasileiras. Para a estimativa da maturação óssea, foram utilizados os métodos de GRAVE & BROWN (1976), que analisam a seqüência de eventos de ossificação observada numa radiografia de mão e punho, e o método de HASSEL & FARMAN (1995) que avalia a maturação óssea, utilizando as variações morfológicas observadas nas vértebras cervicais dois, três e quatro, visua1izadas em radiografias laterais cefalométricas. A amostra estudada foi composta de 240 indivíduos brasileiros, de ambos os sexos, aparentando bom estado de saúde e com idade variando de 7 a 15 anos. Foram formados nove grupos, distribuídos por sexo e por idade cronológica com intervalo de 12 meses de idade entre cada grupo. As radiografias obtidas foram examinadas e reencaminhadas por seis avaliadores, e os dados obtidos foram submetidos ao teste estatístico de SPEARMAN. Os resultados encontrados demonstraram que, para a determinação do estágio de maturação óssea em que o indivíduo se encontra, o método que utilizou radiografias de mão e punho, GRAVE & BROWN (1976), apresentou correlações intra e inter-avaliadores maiores que os apresentados pelo método de HASSEL & FARMAN (1995), independente do sexo e da idade do indivíduo. Foi possível correlacionar os dois métodos e o smto de crescimento puberal ocorreu precocemente na população estudada / Abstract: The aim of the present work was to evaluate the applicability and the reliability of two methods of skeletal maturation in Brazilian children. ORAVE & BROWN (1976) skeletal maturation method, that use the sequence of ossification events observed in hand wrist radiographs and the method of HASSEL & F ARMAN (1995) that evaluates skeletal maturation using the morphologic variations observed in the cervical vertebras two, three and from, visualized in lateral cefalometric x-rays. The sample was composed by 240 Brazilian children, of both sexes, in good hea1th condition and with age from 7 to 15 years. Nine groups were formed, distributed by sex and chronologica1 age, with interval of 12 months among each group. The radiographs were examined and reexamined by six examiners, and the obtained data were submitted to the statistica1 test of SPEARMAN. The results demonstrated that, for the determination of the bony maturation level of the individual, ORA VE & BROWN method presented better correlation intra and inter examiners than HASSEL & F ARMAN method. However, both methods studied proved to be capable to esteem the occurrence of the pubertal growth spurt / Mestrado / Mestre em Radiologia Odontológica
233

Estudo da assimetria facial esqueletica e dimorfismo sexual em norma frontal, de individuos com oclusão dentaria classe I e classe II subdivisão de Angle

Vellwock, Joseane 06 January 2001 (has links)
Orientador : Francisco Haiter Neto / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T03:53:31Z (GMT). No. of bitstreams: 1 Vellwock_Joseane_M.pdf: 6829441 bytes, checksum: 7820bf10e43d3a51c4d25447ce80d7a9 (MD5) Previous issue date: 2001 / Resumo: Esta pesquisa teve como objetivo verificar a incidência de assimetria crânio-facial e dimorfismo sexual em indivíduos Classe I de Angle com oclusão próxima à normal e indivíduos portadores de má oclusão Classe II subdivisão de Angle. A amostra foi composta por 71 indivíduos voluntários, leucodermas, de idade compreendida entre 18 e 35 anos, com média de 22 anos e 2 meses, brasileiros. Foram realizadas radiografias em norma póstero-anterior, padronizadas, com o paciente posicionado no cefalostato tendo o plano horizontal de Frankfort paralelo ao solo. A partir das telerradiografias foram traçados os cefalogramas onde foram feitos os desenhos anatômicos, a marcação dos pontos cefalométricos pré-estabelecidos, os traçados cefalométricos e as devidas medições. A união entre 25 pontos cefalométricos (7 sagitais e 9 bilaterais) deu origem a 62 linhas e 54 medições angulares, lineares de largura de face em mm, e de área em mm2, para a verificação do posicionamento das estruturas faciais e avaliação das assimetrias em cada um dos 71 cefalogramas. Analisando os resultados encontrados neste trabalho, concluímos que os indivíduos das duas amostras, Classe I e Classe II subdivisão de Angle, apresentaram assimetria esquelética; encontramos dimorfismo sexual para a maioria das medidas lineares e de área, sendo as do gênero masculino maiores; com exceção das medidas angulares onde o gênero feminino apresentou-se maior na amostra de Classe I; não encontramos associação entre a maior ou menor mensuração em relação à Linha Mediana de Referência ao tipo de oclusão encontrado na hemi arcada, na amostra de Classe II subdivisão e não nos foi possível afirmar a existência de um único lado de domínio, mas sim de pontos que predominam em sua largura variando com o gênero e tipo de oclusão do indivíduo / Abstract: The aim of this study was to verify the incidence of skeletal asymmetry and sexual dimorphism of individuals with Angle's Class I occlusion within the normal limits, and individuals with Angle's Class II subdivision malocclusion. The sample consisted of seventy-one Caucasians aging 18 to 35 years (mean age=22.2) who volunteered for this study. Standardized postero-anterior (PA) cephalograms were taken, having the Frankfort plane parallel to the ground. Using the obtained cephalograms, the cephalometric tracing was established. The union of 25 cephalometric landmarks (7 sagittal and 9 bilateral) originated 62 lines and 54 angular measurements of the facial width, expressed in millimeters and square millimeters, in order to verify the positioning of the facial structures and to evaluate facial asymmetry of the seventy-one cephalograms. The results indicated that both groups presented skeletal asymmetry. Sexual dimorphism was found for most of the linear and area measurements, especially for males, except for angular measurements that were larger for Angle's Class I females. No correlation was found between the large and short measurements in relation to the Median Reference Line to the type of occlusion found for subjects with Angle's Class II subdivision malocclusion. No evidence was found of an existent dominant side however, predominant landmarks in width varying with the kind and type of occlusion were found / Mestrado / Mestre em Radiologia
234

Avaliação da eficacia do posicionador mandibular de Sarmento nas telerradiografias laterais da cabeça

Pereira Neto, João Sarmento, 1957- 22 February 2001 (has links)
Orientador : Maria Beatriz Borges de Araujo Magnani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T05:38:40Z (GMT). No. of bitstreams: 1 PereiraNeto_JoaoSarmento_D.pdf: 9224938 bytes, checksum: e32467023613c9810a9aecef0ca08976 (MD5) Previous issue date: 2001 / Resumo:O objetivo da presente pesquisafoi testar o "Posicionador Mandibular de Sarmento para telerradiografias da cabeça em norma lateral". A hipótese consistiu em verificar a diferença entre as grandezas lineares e angulares pelo método convencional e as com posicionador mandibular. Foram analisadas oito grandezas angulares (SNA, SNB, ANB, FMA, FMlA, IMPA, ANG.Z e PI.Ocl.) e cinco grandezas lineares (AO-BO, AFA, AFP, QT e LS) e o lAF . Os resultados demonstraram significância estatística ao teste t para dados pareados para as grandezas SNB, FMA e PI.OCL, ao nível de p = 0,01 e 0,05. Com base na análise dos resultados obtidos, concluímos que o dispositivo foi efetivo no controle da estabilidade do terço inferior da face, durante as tomadas telerradiografias da cabeça em norma lateral. As grandezas angulares SNB, FMA e PI.Ocl. apresentaram maior variabilidade quando comparadas com as fornecidas pela tomada de raio X pelo método convencional / Abstract: The objective of the present research went to test the "Sarmento's Mandibular Positioner for cephalometric radiography of the head in lateral norm". The hypothesis consisted of verifying the difterence among the linear and angular greatness for the conventional method and the with mandibular positioner. Eight angular measurements were analyzed (SNA, SNB, ANB, FMA, FMIA, IMPA, ANG.l and PLOcL) and five linear (AO-BO, AFA, AFP, QT and LS) and IAF. The results demonstrated statistical significance to the test t for SNB, FMA and PLOCL, at the levei of p = 0,01 and 0,05. With base in the analysis of the obtained results, we concluded that the device was eftective in the control of the stability of the inferior third of the face The angular greatness SNB, FMA and PLOcL they presented larger variability when compared with supplied them for the ray taking X for the conventional method. KEY-WORDS: Cephalometry; cephalostat; mandibular positioner / Doutorado / Ortodontia / Doutor em Radiologia Odontológica
235

Embolização das arterias uterinas como tratamento de miomas sintomaticos

Martins, Mauricio de Sena 31 July 2018 (has links)
Orientadores: Gustavo Antonio de Souza, Cecilia Maria Roteli Martins / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-07-31T14:57:07Z (GMT). No. of bitstreams: 1 Martins_MauriciodeSena_D.pdf: 1215934 bytes, checksum: 1b03cb75f02b54915711c5e4394ba117 (MD5) Previous issue date: 2001 / Doutorado
236

Tecnologias de exame da carie dentaria : o desafio de seu uso sob diferentes criterios de diagnostico / Caries detection technologies : the challenge of their use under different caries diagnostic criteria

Silva, Renato Pereira da 10 February 2009 (has links)
Orientadores: Antonio Carlos Pereira, Andrea Videira Assaf / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-14T21:30:50Z (GMT). No. of bitstreams: 1 Silva_RenatoPereirada_D.pdf: 1159346 bytes, checksum: 25a8564419a1acce9e9d381386be43cc (MD5) Previous issue date: 2009 / Resumo: O padrão mundial de desenvolvimento da doença cárie dentária tem um dentado a complexidade do diagnóstico de lesões cariosas, principalmente em superfícies dentárias oclusais, por meio do tradicional exame clínico visual-tátil, constituindo um dos grandes desafios da Odontologia em Saúde Coletiva. O objetivo deste estudo foi verificar a reprodutibilidade (estatística Kappa [?] intra e interexaminador) e validade (área sob a curva ROC [AZ]) das tecnologias adjuntas de diagnóstico de cárie "iluminação artificial" (CL2), "radiografia interproximal bitewing" (BW), "transiluminação por FOTI" (FT) e "exame por fluorescência laser (DIAGNOdent®)" (DD), isoladamente ou em associação ao exame clínico visual-tátil (CL1), sob condições epidemiológicas, adotando-se os critérios diagnósticos OMS (D3) e OMS+LI (D1). Para o estudo da reprodutibilidade, 13 crianças, com baixa a alta prevalência de cárie, na faixa etária de 12 anos, da rede pública de ensino de Piracicaba, SP, foram aleatoriamente selecionadas, contando com a participação de 1 examinador padrão e 3 examinadores experientes. Para o estudo da validade, 165 crianças, com as mesmas características, foram selecionadas, contando com participação de 1 examinador padrão e 1 examinador experiente. A reprodutibilidade (intra/interexaminador), por superfícies dentárias, sob os critérios diagnósticos D3 e D1, foi "quase perfeita" para os exames CL1 (D3: ?intra=0,91/?inter=0,85; D1: ?intra=0,89/?inter=0,84), CL2 (D3: intra=0,91/?inter=0,85; D1: ?intra=0,88/?inter=0,83), BW (D3: intra=0,95/?inter=0,92; D1: ?intra=0,99/?inter=0,90) e FOTI (D3: intra=0,97/?inter=0,93; D1: ?intra=0,87/?inter=0,83) e "sofrível" para o exame DD D3: ?intra=0,36/?inter=0,35; D1: ?intra=0,30/?inter=0,32). As associações de tecnologias diagnósticas CL2+FT+DD+BW (AZ-D1=0,8541; AZ-D3=0,6963), para superfícies oclusal + proximais, CL2+DD+BW (AZ-D1=0,8187; AZ-D3=0,6650), para superfície oclusal, e CL2+FT+BW (AZ-D1=0,7234; AZ-D3=0,6836), para superfícies proximais, apresentaram maior validade, sob os critérios diagnósticos D1 e D3, respectivamente. Conclui-se que os exames CL1, CL2, FT e BW apresentam uma reprodutibilidade compatível com a realização de levantamentos epidemiológicos de cárie dentária, e que as associações CL2+FT+DD+BW, CL2+DD+BW e CL2+FT+BW são os melhores métodos de diagnóstico para as superfícies dentárias oclusal + proximais, oclusal e proximais, respectivamente, sob os critérios diagnósticos D1 e D3, em condições epidemiológicas. / Abstract: The world development pattern of dental caries disease has increased the complexity of carious lesions diagnosis especially in occlusal surfaces by the visual-tactile exam, constituting one of the great challenges of the Public Health Dentistry. The aim of this study was to verify the reproducibility (intra and interexaminer Kappa [?] statistics) and the validity (area under the ROC curve [AZ]) of the "artificial illumination" (CL2), "bitewing radiographs" (BW), "transillumination by FOTI" (FT) and "laser fluorescence examination (DIAGNOdent®) " (DD), adjunct technologies of dental caries diagnosis, separately or in association with the visual-tactile exam (CL1), under epidemiological settings and WHO (D3) and WHO+IL (D1) diagnostic criteria. Concerning the reproducibility, 1 standard and 3 experienced examiners examined 13 schoolchildren (twelve-years-old) enrolled in public schools from Piracicaba, SP. The reproducibility sample were randomly selected and presented low to high dental caries prevalence. In relation to the validity, 1 standard and 1 experienced examiner examined 165 twelve-years-old schoolchildren that presented the same characteristics of the reproducibility sample. The (intra/interexaminer) reproducibility, for dental surfaces, under the D3 and D1 diagnostic criteria, was almost perfect for the CL1 (D3: ?intra=0.91/?inter=0.85; D1: ?intra=0.89/?inter=0.84), CL2 (D3: ?intra=0.91/?inter=0.85; D1: ?intra=0.88/?inter=0.83), BW (D3: ?intra=0.95/?inter=0.92; D1: ?intra=0.99/?inter=0.90) e FOTI (D3: ?intra=0.97/?inter=0.93; D1: ?intra=0.87/?inter=0.83) examinations and it was fair for the DD (D3: ?intra=0.36/?inter=0.35; D1: ?intra=0.30/?inter=0.32) examination. The diagnostic technologies associations, CL2+FT+DD+BW (AZ-D1=0.8541; AZ-D3=0.6963), for occlusal + approximal surfaces, CL2+DD+BW (AZ-D1=0.8187; AZ-D3=0.6650), for occlusal surface, and CL2+FT+BW (AZ-D1=0.7234; AZ-D3=0.6836), for approximal surfaces, presented the largest validity under the D1 and D3 diagnostic criteria, respectively. It was concluded that the CL1, CL2, FT and BW examinations present a reproducibility compatible with the execution of epidemiological surveys of dental caries, and that the CL2+FT+DD+BW, CL2+DD+BW and CL2+FT+BW technologies associations are the best methods of examinations for occlusal + approximal surfaces, occlusal surfaces and approximal surfaces under D1 and D3 diagnostic criteria in epidemiological settings respectively. / Doutorado / Saude Coletiva / Doutor em Odontologia
237

Variação interobservador e valor preditivo positivo da categoria 4 do BI-RADS 'MARCA REGISTRADA' para mamografia / Reader variability and preditive positive value for mammography BI-RADS 'TRADE MARK' category 4

Kestelman, Fabiola Procaci 15 May 2008 (has links)
Orientadores: Gustavo Antonio de Souza, Luis Otavio Sarian / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-11T03:29:01Z (GMT). No. of bitstreams: 1 Kestelman_FabiolaProcaci_M.pdf: 577232 bytes, checksum: acf1199f373751447b51be36a9c1cb18 (MD5) Previous issue date: 2008 / Resumo: Objetivo: Determinar o valor preditivo positivo das categorias 4A, 4B e 4C da 4ª edição do BI-RADS e determinar a variação interobservador desta classificação em lesões submetidas à biópsia cirúrgica. Métodos: Este estudo retrospectivo foi conduzido no Instituto Nacional de Câncer (INCA), Rio de Janeiro, Brasil. Os casos para análise foram selecionados no banco de dados do setor de radiologia, entre mulheres submetidas à marcação pré-cirúrgica para biópsia cirúrgica entre janeiro de 1999 e dezembro de 2002, que foram previamente classificadas como BIRADS 4. As mamografias foram revisadas por três radiologistas especializados em radiologia mamária. Os avaliadores classificaram as lesõs considerando a probabilidade de malignidade, dentro da categoria 4, em 4A, 4B e 4C. Para a análise estatética, foi realizado um consenso a partir dos resultados dos três radiologistas. A variação interobservador foi calculada utilizando o índice de kappa ponderado. Resultados: De 775 lesõs, o resultado consensual mostrou 235 (30,3%) mamografias classificadas como 4A, 338 (43,6%) como 4B e o restante 161 (20,8%) como 4C. Os radiologistas não obtiveram consenso em 41 (5,3%) lesões. A concordância geral entre os avaliadores foi moderada (?=0,44), variando entre ?=0,38 considerando os radiologistas dois e tr? e ?=0,54 considerando os radiologistas um e dois. A concordância variou de mínima (categoria 4B, k= 0,09) a pobre, considerando as categorias 4A e 4C. A proporção de lesões nos grupos 4A, 4B e 4C foi similar e o VPP foi progressivo (23,0%, 47,6% e 72,7%, respectivamente). Conclusão: O VPP das categorias 4A, 4B and 4C foi progressivo e a concord?cia entre os observadores foi moderada / Abstract: Purpose: To determine the predictive positive value of BI-RADS 4th edition categories 4A, 4B and 4C and determine the inter-observer variability for lesion on which biopsies had been performed. Methods: This cross-sectional study was conducted at the National Institute of Cancer (INCA), Rio de Janeiro, Brazil. Cases for analysis were selected from the medical records among women who were submitted to breast needle localization and diagnostic surgical biopsy, from January 1999 to December 2002, and which had been previously categorized as BIRADS 4. The mammograms were reviewed by three senior breast imaging radiologists. Readers provided a BI-RADS final assessment category to indicate the probability of malignancy in category 4. For statistical calculations, a ¿consensus¿ variable was created using the outputs from the three assessors. Interobserver variability for each subcategory was determined using the weighted kappa statistic. Results: Of 775 lesions, ¿consensual¿ assessment rendered 235 (30.3%) mammograms classified as 4A, 338 (43.6%) as 4B and the remainder 161 (20.8%) as 4C. Radiologists did not reach a consensus in 41 (5.3%) exams. Overall agreement between raters was moderate (?=0.44), ranging from ?=0.38 between raters two and three to ?=0.54 between radiologists one and two. Agreement between raters ranged from slight (category 4B, k=0.09) to fair, considering categories 4A and 4C. In BI-RADS 4B and 4C groups, the proportion of each abnormality in the whole group was similar to that in 4A, but the PPV were higher. Conclusions: The PPV for subcategories 4A, 4B and 4C was progressive and the agreement between readers was moderate. Key words: Breast cancer, mammography, BI-RADS / Mestrado / Tocoginecologia / Mestre em Tocoginecologia
238

Avaliação clinica de quatro metodos de diagnostico de lesões de carie oclusal

Zanin, Luciane 21 February 2002 (has links)
Orientador: Marcelo de Castro Meneghim / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-01T02:14:22Z (GMT). No. of bitstreams: 1 Zanin_Luciane_M.pdf: 2114858 bytes, checksum: 96ffe46506b0ae67abddeb17a371d601 (MD5) Previous issue date: 2002 / Resumo: O objetivo desse estudo foi avaliar diferentes métodos de diagnóstico clínico: laser fluorescente (sistema DIAGNOdent¿MARCA REGISTRADA¿, radiografia digital interproximal (sistema CDR), radiografia interproximal convencional e o exame clínico visual, para o diagnóstico de lesões na superficie oclusa!. A amostra foi constituída de 153 primeiros molares permanentes com microcavidades em crianças de 6 a 8 anos de idade de ambos os sexos, residentes em Piracicaba, São Paulo. O método de validação utilizado foi a abertura de cavidade. Os valores de sensibilidade e predição positiva foram calculados para cada método de diagnóstico. Os resultados mostraram que 96 dentes pela inspeção visual apresentaram microcavidades (MC), destas 57,3%, estavam em esmalte e 42,7% estavam em dentina. Em 57 dentes, as microcavidades estavam associada à presença de mancha branca (MC + MB), 91,2% destas estavam e dentina e apenas 8,8% em esmalte. A sensibilidade dos métodos para lesões em esmalte foi 0,99 para aparelho DIAGNOdent; 0,77 para o exame radiográfico convencional e 0,75 para o exame radiográfico digital. Os valores de predição positiva encontrados foram 0,97 para aparelho DIAGNOdent; 1,00 para o exame radiográfico convencional e 0,77 para o exame radiográfico digital. A sensibilidade dos métodos para lesões em dentina foi 0,99 para aparelho DIAGNOdent; 1,00 para o exame radiográfico convencional e 0,95 para o exame radiográfico digital. Os valores de predição positiva encontrados foram 0,80 para aparelho DIAGNOdent 0,92 para o exame radiográfico convencional e 0,94 para o exame radiográfico digital. O laser fluorescente mostrou 19,3% de decisões falso positivas. Conclui-se que lesões de microcavidade associada à uma lesão de mancha branca pode ser considerada um bom critério de diagnostico de lesões em dentina. Os métodos radiográficos foram menos precisos no diagnóstico de lesões em esmalte sendo mais precisos no diagnóstico de lesões em dentina. O laser fluorescente pode ser considerado um bom método de diagnóstico de lesões iniciais, devendo ser considerada a alta porcentagem de decisões falso positivas do aparelho o que pode levar a condutas incorretas pelo Cirurgião- Dentista / Abstract: The goaI of this study was to compare different clinicaI diagnostic methods: fluorescent laser (DIAGNOdent system), direct digital radiograph (CDR system), bitewing radiographs and visual inspection for occlusal surf.aces. The sample w.as constitutM of 153 first permanent molars with microcavities of 6 to 8-year-old children ofboth sexes, who live in Piracicaba, SP. The validation method used was operative intervention. The sensitivity and positive prediction values were calculated to diagnosys methods. The results showed that by visual inspection 96 teeth had microcavity lesions and of these, 57.3% were in enamel and 42.7% were in dentine. In 57 teeth, an association was found between white spite lesions and microcavities, of which 91.2% were in dentine and on1y 8.8% were in enamel. The values concerning the sensitivity of the methods on enamel lesions were 0.99 for fluorescent laser; 0.77 for bitewing radiographs; and 0.75 for direct digital radiograph. The positive prediction values were 0.97 for fluorescent laser; 1.00 for bitewing radiographs; and 0.77 for direct digital radiograph. The sensitivity values of the methods on dentinal lesions were 0.99 for fluorescence laser; 1.00 for bitewing radiographs and 0.95 for direct digital radiograph. The positive prediction values were 0.80 for fluorescent laser; 0.92 for bitewing radiographs; and 0.94 for direct digital radiograph. The fluorescent laser showed 19.3% false positive decisions. In conclusion, microcavity lesions associated with white spot lesions can be considered a good criterion for diagnosing dentinal lesions. The accuracy of the radiograph method was low for detecting enamel lesions and high for detecting dentinal lesions. Fluorescent laser can be considered a good method for diagnosing initial lesions, if taking into consideration the high percentage of false positive decisions / Mestrado / Cariologia / Mestre em Odontologia
239

Estudo de dois sistemas radiograficos digitais submetidos a diferentes condições de trabalho em relação ao ruido

Paganini, Gisela Andre 31 October 2001 (has links)
Orientador: Francisco Haiter Neto / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-01T08:05:18Z (GMT). No. of bitstreams: 1 Paganini_GiselaAndre_D.pdf: 3622509 bytes, checksum: 0a3a66ef45c71d609b9b77961f928382 (MD5) Previous issue date: 2001 / Resumo: O presente trabalho teve como objetivo avaliar o ruído de imagens digitais dos sistemas Digora e DenOptix em diferentes graus de luminosidade do ambiente onde os sensores eram manipulados para serem introduzidos no scanner e lugares onde os sensores foram posicionados em relação ao monitor com tempos de espera pré-fixados. Foi estudado também o tempo total de dessensibilização da placa de fósforo do sistema DenOptix, expondo-as a negatoscópios de diferentes intensidade de luz. A análise objetiva das imagens de phantoms foi realizada utilizando-se pacote computacional "LISIER". A análise dos resultados mostrou que o sistema Digora ofereceu melhor qualidade de imagem com menor quantidade de ruído em relação ao sistema DenOptix, não se alterando sob as diferentes condições de luminosidade do ambiente. Para o sistema DenOptix, quando a leitura foi realizada em ambiente com a luz acesa, ocorreu um aumento do ruído nas placas, não sendo porém, subjetivamente significante. Com relação ao posicionamento dos sensores, com o acréscimo do tempo houve um aumento na quantidade de ruído detectada na imagem e o ruído foi maior nos sensores posicionados lateralmente ao monitor. Pela análise subjetiva das imagens digitais, não foi possível perceber nenhuma influência da iluminação ou da radiação emitida pelo monitor. Em relação à dessensibilização da placa do sistema DenOptix, negatoscópio. Pode-se concluir que este fator está diretamente relacionado com a dose de radiação aplicada ao sensor de placa de fósforo e com a intensidade da luz do negatoscópio / Abstract: The aim of the present work was to evaluate the noise in the digital images of the systems Digora and DenOptix in different intensity light environment. It was toa studied the time total to erase the plate of system DenOptix. The objective analysis of the phantoms images was carried through by means a computacional programo The results had show that the Digora system had the best image quality with low noise without alteration in different condition of the environment DenOptix system, when the read was realized in environment with light on, it had a increase of the noise but without estatistic difference. With relation on the sensors position, with the increase of the time, increased the noise in the image in lateral position on the sensors wasgreater. Than in front of the monitor the subjective assessment do not show the influence of the environment light or the radiation of the computer. In related a erasing the plate of system DenOptix, it conc1uded that this factor is direct associated to the radiation dose and the intensity of light of the negatoscope / Doutorado / Radiologia Odontologica / Doutor em Radiologia Odontológica
240

Avaliação de diferentes metodos empregados para o diagnostico da carie dentaria

Mialhe, Fabio Luiz, 1972- 05 June 2002 (has links)
Orientador : Antonio Carlos Pereira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-01T14:43:13Z (GMT). No. of bitstreams: 1 Mialhe_FabioLuiz_M.pdf: 2778035 bytes, checksum: 854420f84f8789d20fa13ecbe0733773 (MD5) Previous issue date: 2002 / Resumo: O maior contato das populações com os compostos fluoretados é apontado, segundo vários pesquisadores, como o principal responsável pela queda da prevalência da cárie dentária, verificada mundialmente, durante as últimas décadas. As cavitações cariosas, quando ocorrem, estão surgindo num estágio bem mais avançado de desenvolvimento da doença, que em épocas de alta prevalência e, portanto, a morfologia das lesões cariosas, está se alterando. Tal fato tem dificultado o diagnóstico da presença e profundidade das lesões cariosas, causando uma baixa concordância entre diferentes examinadores, quando examinando uma mesma amostra, para o diagnóstico e tipo de tratamento indicado para essa. Desse modo, observa-se que os dentistas podem concordar entre si, quanto ao diagnóstico da presença de uma lesão cariosa bem estabelecida, mas podem divergir entre si ao examinar uma superfície que apresenta uma lesão em estágios iniciais, através dos métodos tradicionais de diagnóstico, ou seja, o exame clínico e radiográfico. Outros métodos vêm sendo desenvolvidos para se tentar melhorar a capacidade do clínico em diagnosticar as lesões cariosas, entre eles, o exame videoscópico, FOTI e laser fluorescente, ainda que, pouco explorados pela literatura. Dentro desse contexto, devido à dificuldade encontrada pelos dentistas em diagnosticar e tratar corretamente as lesões cariosas, o presente trabalho teve como objetivos: 1) verificar a concordância no diagnóstico e tratamento da cárie em superfícies oclusais, através dos exames clínico e radiográfico, realizado por dentistas que trabalham em consultório particular, examinando uma mesma amostra e, calcular os prováveis custos envolvidos nessas variações; 2) avaliar "in vitro" o desempenho e reprodutibilidade dos métodos visual, videoscópico, FOTI e um aparelho de laser fluorescente (DIAGNOnodent®-Kavo) para o diagnóstico de cárie oclusal, utilizando o exame histológico como método de validação; 3) avaliar "in vivo" o desempenho dos métodos clínico, radiográfico e FOTI para o diagnóstico de lesões cariosas em superfícies proximais, em relação ao exame visual direto das superfícies, através da separação temporária dos dentes. Dentro das condições experimentais destes trabalhos, verificou-se que: 1) houve uma ampla variação no diagnóstico e indicação de tratamento para cáries em superfícies oclusais sugerido pelos dentistas, bem como, no custo dos tratamentos; 2) o exame visual, videoscópico e FOTI apresentaram baixos valores de sensibilidade, porém altos valores de especificidade para o diagnóstico de lesões cariosas localizadas em superfícies oclusais, enquanto o laser DIAGNOdent®apresentou elevados valores de sensibilidade às custas de um grande número de diagnósticos falso-positivos para o diagnóstico de cáries localizadas em nível de dentina; 3) O exame radiográfico apresentou o melhor desempenho para o diagnóstico de lesões nãocavitadas e cavitadas em relação ao exame clínico e FOTI para superfícies proximais / Abstract; The globally verified decline in dental caries prevalence is particularly related to the increased use of fluorides toothpaste, and carious lesion was observed to progress much slower delaying cavitation than in high prevalence era. Such fact made it rather difficult for different examiners to diagnose caries. Dentists may agree on the presence of a carious lesion when it is well established and obvious to the naked eye, but they might will sometimes disagree with each other when examining a surface which may bear an early lesion, making it difficult for them to diagnose and treat carious lesions. The main diagnostic tools today are the still mirror, light, explorer and the radiographic examination. However, new technology has been developed for this purpose. Therefore the aim of the present work was: 1) to verify the agreement of a group of dentists on dental treatment and diagnostic decisions and to calculate the probable costs related to the treatment; 2) to evaluate " in vitro " the accuracy and reproducibility of the following methods: clinical, videoscope, FOTI, and a fluorescent laser device (Diagnodent® -Kavo) for the diagnosis of occlusal caries, using the histologic exam as validation; 3) to compare "in vivo" the performance of the clinical, FOTI and radiographic exams with that of the direct visual exams, for the diagnosis of dental caries on approximal surfaces. Within the experimental conditions of these study, it was verified that: 1) there was a wide variation in the diagnosis and indication of caries treatment for occlusal surfaces as well as in the cost of the treatment suggested by the dentists; 2) the visual, videoscope and FOTI exams presented low sensitivity but high specificity values for the diagnosis of occlusal surfaces. The laser DIAGNOdent® presented high sensitivity values but at the expense of great number of false positive diagnoses 3) the radiographic exam showed the best accuracy for the diagnosis of noncavitated and cavitated caries lesions in comparison with the clinical and FOTI exams / Mestrado / Cariologia / Mestre em Odontologia

Page generated in 0.0914 seconds