Spelling suggestions: "subject:"radiopacidade"" "subject:"radiopacidades""
11 |
Avaliação da radiopacidade, escoamento, pH e da liberação de íons cálcio de um cimento endodôntico biocerâmico / Evaluation of Radiopacity, flow, pH and release of calcium ions of a bioceramic root canal sealerCandeiro, George Taccio de Miranda 02 October 2012 (has links)
O objetivo do presente trabalho foi avaliar as propriedades físico-químicas de um cimento endodôntico biocerâmico, Endosequence BC Sealer (Brasseler USA, Savannah, GA, EUA). Radiopacidade, escoamento, pH e liberação de íons cálcio (Ca2+) foram analisadas e os resultados foram comparados aos do cimento AH Plus (Dentsply De Trey Gmbh, Konstanz, Alemanha). A radiopacidade e o escoamento foram avaliados de acordo com as normas ISO 6876/2001. Para o teste de radiopacidade, anéis metálicos com 10 mm de diâmetro e 1 mm de altura foram preenchidos com os cimentos. O valor da radiopacidade foi determinado de acordo com a densidade radiográfica, representada em mm Al. A análise do escoamento foi feita com 0,05 mL de cada cimento colocados sobre uma placa de vidro. Outra placa de vidro, com 20 g, foi cuidadosamente colocada sobre o cimento e sobre esta um peso de 100 g, totalizando 120 g, que permaneceram por 7 minutos. Em seguida, foram medidos os diâmetros maiores e menores dos discos formados, sendo esta feita com um paquímetro digital. A liberação de íons cálcio (Ca2+) e o pH foram medidos nos períodos de 3, 24, 72, 168 e 240 horas, com o auxílio de um espectrofotômetro e pHmetro, respectivamente. Os resultados foram analisados estatisticamente pelos testes ANOVA e Tukey, sendo considerado significante quando p<0,05. O cimento biocerâmico analisado apresentou radiopacidade (3,84 mm Al) significantemente menor do que o AH Plus (6,90 mm Al). Foi observado que o cimentos Endosequence BC Sealer e o AH Plus apresentaram escoamentos de 26,96 mm e 21,17 mm, respectivamente (p<0,05). O cimento biocerâmico apresentou maior pH e maior liberação de íons cálcio (Ca2+) do que o cimento AH Plus (p<0,05). Concluiu-se que o cimento Endosequence BC Sealer apresentou valores de radiopacidade e de escoamento em concordância com as norma ISO 6876/2001. Os valores de pH e de liberação de íons cálcio (Ca2+) foram favoráveis para um cimento endodôntico. / The aim of the present study was to evaluate the physicochemical properties of a bioceramic root canal sealer, Endosequence BC Sealer. Radiopacity, pH, release of calcium ions (Ca2+) and flow were analyzed and the results were compared with AH Plus cement. Radiopacity and flow were evaluated according to ISO 6876/2001 standards. For the radiopacity analysis, metallic rings with 10 mm in diameter and 1 mm of thickness were filled with cements. The radiopacity value was determined according to radiographic density (mm Al). The flow test was performed with 0.05 mL of cement placed on a glass plate. A 120-g weight was carefully placed over the cement. The largest and smallest diameters of the disks formed were measured using a digital caliper. The release of Ca2+ and pH were measured at periods of 3, 24, 72, 168 and 240 hours, with spectrophotometer and pHmeter, respectively. Data were analyzed by ANOVA and Tukeys test (p<0.05). The bioceramic endodontic cement showed radiopacity (3.84 mm Al) significantly lower than that of AH Plus (6.90 mm Al). The pH analysis showed that Endosequence BC Sealer showed pH and release of Ca2+ greater than those of AH Plus (p<0.05), during the experimental periods. The flow test revealed that the BC Sealer and AH Plus presented flow 26.96 mm and 21.17 mm, respectively (p<0.05). Endosequence BC Sealer showed radiopacity and flow according to ISO 6876/2001 recommendations. The others physicochemical properties analyzed demonstrated favorable values for a root canal sealer.
|
12 |
Estudo da radiopacidade de materiais odontológicos indicados como base e forramento de restaurações. Análise através da radiografia digital / Study of the radiopacity of dental materials used as base and liner of restorations. Analysis by digital radiographicLachowski, Karina Monteleone 03 June 2011 (has links)
A radiopacidade é um importante pré-requisito para materiais utilizados como base e forramento de restaurações, pois possibilita que o profissional identifique a presença do material e permita sua diferenciação com a estrutura dental adjacente. O objetivo desse estudo foi avaliar a radiopacidade de materiais indicados como base e forramento e comparar com a radiopacidade do esmalte, dentina e escala de alumínio. Para isso, foram analisadas 16 marcas comerciais de cimento de ionômero de vidro, 8 marcas de resina composta flow e 4 marcas de cimento de hidróxido de cálcio. Foram confeccionados três conjuntos de três corpos de prova de 4 mm de diâmetro, com espessuras de 1, 2 e 3 mm para cada cimento de ionômero de vidro e resina composta flow e de 1 mm para cada cimento de hidróxido de cálcio. Foram feitas secções transversais de coroas de três terceiros molares humanos para obtenção de espécimes de esmalte e dentina com espessura de 1, 2 e 3 mm. Como controle, uma escala de alumínio padrão com nove degraus de espessura foi utilizada. As tomadas radiográficas foram feitas com o sistema digital RVG 5000 Kodak (Kodak Company, França) e tempo de exposição de 0.32 segundos. As imagens obtidas foram trabalhadas no programa Image Tool® para obtenção dos valores médios de cinza. A análise estatística ANOVA, seguida pelo teste de Tukey (p0.05) detectou diferenças consideráveis entre os materiais da mesma categoria e entre as espessuras. Algumas marcas comerciais apresentaram radiopacidade inadequada segundo as normas ISO 4049 e 9917 (Ionomaster, Maxxion, Bioglass R, Bioglass F, Vidrion R e Vidrion F), apresentando radiopacidade inferior à da dentina, insuficiente para um correto diagnóstico. Todas as resinas compostas flow e cimentos de hidróxido de cálcio estudados apresentam radiopacidade superior a da dentina. As marcas comerciais Vitro Fil, Magic Glass, Vitrebond, Riva SC, Riva LC, Fill Magic, Opallis, Surefil Tetric N, Tetric, Hydro C, Hydcal e Liner apresentaram radiopacidade igual ou superior a do esmalte, em todas as espessuras. De um modo geral, o aumento de espessura dos materiais estudados aumenta significativamente sua radiopacidade. Conclui-se que existem materiais indicados como base e forramento de restaurações com radiopacidade inadequada para serem detectados radiograficamente. / Radiopacity is an important pre-requisite for base and liner materials, once it allows the professional to identify the presence of the material and makes its differentiation from the adjacent tooth structure possible. The aim of this study was to evaluate the radiopacity of liner and base materials and compare to the radiopacity of enamel, dentin and aluminum stepwedge. For this, 16 glass ionomer cements, 8 flowable resin composites and 4 calcium hydroxide cements were analysed. It was prepared three sets of three test specimens with 4 mm in diameter and thicknesses of 1, 2 and 3 mm for each glass ionomer cement and flowable composite and 1 mm for each calcium hydroxide cement. Cross sections were made from crowns of three third molars to obtain specimens of enamel and dentin with thickness of 1, 2 and 3 mm. As a control, a standard aluminum stepwedge with nine steps was used. Radiographs were taken with digital Kodak RVG 5000 (Kodak Company, France) and exposure time of 0.32 seconds. The images were analysed through the program Image Tool ® to obtain the mean grey values. Statistical test ANOVA followed by Tukey test (p 0.05) detected significant differences between the materials of the same category and between the thicknesses. The commercial brands Ionomaster, Maxxion, Bioglass R, Bioglass F, Vidrion R and Vidrion F, presented radiopacity lower than the radiopacity of dentin, insufficient for a correct diagnostic. All flowable resin composites and calcium hydroxide cements studied showed radiopacity superior than dentin. Vitro Fil, Magic Glass, Vitrebond, Riva SC, Riva LC, Fill Magic, Opallis, Surefil, Tetric N, Tetric, Hydro C, Hydcal and Liner showed radiopacity equal to or greater than the enamel for all thicknesses. In general, the increased thickness of the materials studied increases its radiopacity significantly. It was concluded that some materials indicated as base and liner for restorations have and inadequate radiopacity to be detected radiographically.
|
13 |
Avaliação da radiopacidade, escoamento, pH e da liberação de íons cálcio de um cimento endodôntico biocerâmico / Evaluation of Radiopacity, flow, pH and release of calcium ions of a bioceramic root canal sealerGeorge Taccio de Miranda Candeiro 02 October 2012 (has links)
O objetivo do presente trabalho foi avaliar as propriedades físico-químicas de um cimento endodôntico biocerâmico, Endosequence BC Sealer (Brasseler USA, Savannah, GA, EUA). Radiopacidade, escoamento, pH e liberação de íons cálcio (Ca2+) foram analisadas e os resultados foram comparados aos do cimento AH Plus (Dentsply De Trey Gmbh, Konstanz, Alemanha). A radiopacidade e o escoamento foram avaliados de acordo com as normas ISO 6876/2001. Para o teste de radiopacidade, anéis metálicos com 10 mm de diâmetro e 1 mm de altura foram preenchidos com os cimentos. O valor da radiopacidade foi determinado de acordo com a densidade radiográfica, representada em mm Al. A análise do escoamento foi feita com 0,05 mL de cada cimento colocados sobre uma placa de vidro. Outra placa de vidro, com 20 g, foi cuidadosamente colocada sobre o cimento e sobre esta um peso de 100 g, totalizando 120 g, que permaneceram por 7 minutos. Em seguida, foram medidos os diâmetros maiores e menores dos discos formados, sendo esta feita com um paquímetro digital. A liberação de íons cálcio (Ca2+) e o pH foram medidos nos períodos de 3, 24, 72, 168 e 240 horas, com o auxílio de um espectrofotômetro e pHmetro, respectivamente. Os resultados foram analisados estatisticamente pelos testes ANOVA e Tukey, sendo considerado significante quando p<0,05. O cimento biocerâmico analisado apresentou radiopacidade (3,84 mm Al) significantemente menor do que o AH Plus (6,90 mm Al). Foi observado que o cimentos Endosequence BC Sealer e o AH Plus apresentaram escoamentos de 26,96 mm e 21,17 mm, respectivamente (p<0,05). O cimento biocerâmico apresentou maior pH e maior liberação de íons cálcio (Ca2+) do que o cimento AH Plus (p<0,05). Concluiu-se que o cimento Endosequence BC Sealer apresentou valores de radiopacidade e de escoamento em concordância com as norma ISO 6876/2001. Os valores de pH e de liberação de íons cálcio (Ca2+) foram favoráveis para um cimento endodôntico. / The aim of the present study was to evaluate the physicochemical properties of a bioceramic root canal sealer, Endosequence BC Sealer. Radiopacity, pH, release of calcium ions (Ca2+) and flow were analyzed and the results were compared with AH Plus cement. Radiopacity and flow were evaluated according to ISO 6876/2001 standards. For the radiopacity analysis, metallic rings with 10 mm in diameter and 1 mm of thickness were filled with cements. The radiopacity value was determined according to radiographic density (mm Al). The flow test was performed with 0.05 mL of cement placed on a glass plate. A 120-g weight was carefully placed over the cement. The largest and smallest diameters of the disks formed were measured using a digital caliper. The release of Ca2+ and pH were measured at periods of 3, 24, 72, 168 and 240 hours, with spectrophotometer and pHmeter, respectively. Data were analyzed by ANOVA and Tukeys test (p<0.05). The bioceramic endodontic cement showed radiopacity (3.84 mm Al) significantly lower than that of AH Plus (6.90 mm Al). The pH analysis showed that Endosequence BC Sealer showed pH and release of Ca2+ greater than those of AH Plus (p<0.05), during the experimental periods. The flow test revealed that the BC Sealer and AH Plus presented flow 26.96 mm and 21.17 mm, respectively (p<0.05). Endosequence BC Sealer showed radiopacity and flow according to ISO 6876/2001 recommendations. The others physicochemical properties analyzed demonstrated favorable values for a root canal sealer.
|
14 |
Estudo da radiopacidade de materiais odontológicos indicados como base e forramento de restaurações. Análise através da radiografia digital / Study of the radiopacity of dental materials used as base and liner of restorations. Analysis by digital radiographicKarina Monteleone Lachowski 03 June 2011 (has links)
A radiopacidade é um importante pré-requisito para materiais utilizados como base e forramento de restaurações, pois possibilita que o profissional identifique a presença do material e permita sua diferenciação com a estrutura dental adjacente. O objetivo desse estudo foi avaliar a radiopacidade de materiais indicados como base e forramento e comparar com a radiopacidade do esmalte, dentina e escala de alumínio. Para isso, foram analisadas 16 marcas comerciais de cimento de ionômero de vidro, 8 marcas de resina composta flow e 4 marcas de cimento de hidróxido de cálcio. Foram confeccionados três conjuntos de três corpos de prova de 4 mm de diâmetro, com espessuras de 1, 2 e 3 mm para cada cimento de ionômero de vidro e resina composta flow e de 1 mm para cada cimento de hidróxido de cálcio. Foram feitas secções transversais de coroas de três terceiros molares humanos para obtenção de espécimes de esmalte e dentina com espessura de 1, 2 e 3 mm. Como controle, uma escala de alumínio padrão com nove degraus de espessura foi utilizada. As tomadas radiográficas foram feitas com o sistema digital RVG 5000 Kodak (Kodak Company, França) e tempo de exposição de 0.32 segundos. As imagens obtidas foram trabalhadas no programa Image Tool® para obtenção dos valores médios de cinza. A análise estatística ANOVA, seguida pelo teste de Tukey (p0.05) detectou diferenças consideráveis entre os materiais da mesma categoria e entre as espessuras. Algumas marcas comerciais apresentaram radiopacidade inadequada segundo as normas ISO 4049 e 9917 (Ionomaster, Maxxion, Bioglass R, Bioglass F, Vidrion R e Vidrion F), apresentando radiopacidade inferior à da dentina, insuficiente para um correto diagnóstico. Todas as resinas compostas flow e cimentos de hidróxido de cálcio estudados apresentam radiopacidade superior a da dentina. As marcas comerciais Vitro Fil, Magic Glass, Vitrebond, Riva SC, Riva LC, Fill Magic, Opallis, Surefil Tetric N, Tetric, Hydro C, Hydcal e Liner apresentaram radiopacidade igual ou superior a do esmalte, em todas as espessuras. De um modo geral, o aumento de espessura dos materiais estudados aumenta significativamente sua radiopacidade. Conclui-se que existem materiais indicados como base e forramento de restaurações com radiopacidade inadequada para serem detectados radiograficamente. / Radiopacity is an important pre-requisite for base and liner materials, once it allows the professional to identify the presence of the material and makes its differentiation from the adjacent tooth structure possible. The aim of this study was to evaluate the radiopacity of liner and base materials and compare to the radiopacity of enamel, dentin and aluminum stepwedge. For this, 16 glass ionomer cements, 8 flowable resin composites and 4 calcium hydroxide cements were analysed. It was prepared three sets of three test specimens with 4 mm in diameter and thicknesses of 1, 2 and 3 mm for each glass ionomer cement and flowable composite and 1 mm for each calcium hydroxide cement. Cross sections were made from crowns of three third molars to obtain specimens of enamel and dentin with thickness of 1, 2 and 3 mm. As a control, a standard aluminum stepwedge with nine steps was used. Radiographs were taken with digital Kodak RVG 5000 (Kodak Company, France) and exposure time of 0.32 seconds. The images were analysed through the program Image Tool ® to obtain the mean grey values. Statistical test ANOVA followed by Tukey test (p 0.05) detected significant differences between the materials of the same category and between the thicknesses. The commercial brands Ionomaster, Maxxion, Bioglass R, Bioglass F, Vidrion R and Vidrion F, presented radiopacity lower than the radiopacity of dentin, insufficient for a correct diagnostic. All flowable resin composites and calcium hydroxide cements studied showed radiopacity superior than dentin. Vitro Fil, Magic Glass, Vitrebond, Riva SC, Riva LC, Fill Magic, Opallis, Surefil, Tetric N, Tetric, Hydro C, Hydcal and Liner showed radiopacity equal to or greater than the enamel for all thicknesses. In general, the increased thickness of the materials studied increases its radiopacity significantly. It was concluded that some materials indicated as base and liner for restorations have and inadequate radiopacity to be detected radiographically.
|
15 |
Avaliação da radiopacidade de diferentes sistemas cerâmicos livres de metalBeghini, Ana Cristina da Rocha Duque 02 May 2011 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-07-13T15:19:13Z
No. of bitstreams: 1
anacristinadarochaduquebeghini.pdf: 604681 bytes, checksum: 77222c9c607ebf796ce7a6f000f0c9c1 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-13T16:58:18Z (GMT) No. of bitstreams: 1
anacristinadarochaduquebeghini.pdf: 604681 bytes, checksum: 77222c9c607ebf796ce7a6f000f0c9c1 (MD5) / Made available in DSpace on 2016-07-13T16:58:18Z (GMT). No. of bitstreams: 1
anacristinadarochaduquebeghini.pdf: 604681 bytes, checksum: 77222c9c607ebf796ce7a6f000f0c9c1 (MD5)
Previous issue date: 2011-05-02 / No presente estudo avaliou-se a radiopacidade de restaurações cerâmicas livres de
metal de forma objetiva, subjetiva e por meio de MEV/EDS. Foram utilizadas as
cerâmicas: Noritake EX-3 (Noritake), VM13 (Vita), IPS Empress II (Ivoclar Vivadent),
IPS E.max ZirPress (Ivoclar Vivadent) e PM9 (Vita). Para a avaliação objetiva foram
confeccionados cinco corpos de prova nas espessuras de 1, 2, 3 e 4 mm, que foram
radiografados juntamente com uma escala de densidade e uma secção dental,
utilizando-se sistema digital direto. As imagens radiográficas foram submetidas à
leitura de densidade óptica. Para a avaliação subjetiva foram confeccionados
phantoms, simulando a parte posterior das arcadas dentárias, no qual dois dentes
de cada phantom foram submetidos a preparos inlay, restaurados com as cerâmicas
estudadas, e radiografados pela técnica interproximal. Essas radiografias foram
avaliadas por três grupos de examinadores: cirurgiões-dentistas, radiologistas e
protesistas. Para a análise dos elementos químicos que dão características de
radiopacidade aos materiais, foi realizada avaliação pelo MEV/EDS. Os resultados
da avaliação objetiva indicaram diferenças significativas entre as radiopacidades das
cerâmicas estudadas. Para 1 e 2 mm de espessuras todas as cerâmicas
apresentaram radiopacidade superior a da dentina e inferior a do esmalte. A
cerâmica Noritake EX3 apresentou maior radiopacidade em todas as espessuras.
Não se puderam constatar, nas avaliações simulando condições clínicas, as
diferenças de radiopacidades observadas na avaliação objetiva. O grupo dos
cirurgiões-dentistas apresentou a menor acurácia diagnóstica quando comparados
aos grupos de especialistas, sendo que os radiologistas apresentaram a maior
acurácia diagnóstica para cerâmica (0,57). Independente do grupo de avaliadores,
não foi possível a distinção radiográfica entre cerâmicas livre de metal e compósitos.
O resultado da avaliação dos materiais pelo MEV/EDS indicou como possíveis
elementos radiopacificadores: bário para as cerâmicas Noritake EX-3 (2,19%), VM13
(1,04%), PM9 (0,70%) e IPS Empress II (0,70%); e zinco (4,50%) e cério (1,45%)
para a cerâmica IPS E.max ZirPress. / The aim of this study to evaluate the radiopacity of metal-free ceramic restorations in
an objective, subjective and by SEM and EDS. Ceramics were used: Noritake EX-3
(Noritake), VM13 (Vita), IPS Empress II (Ivoclar Vivadent), IPS e.max ZirPress
(Ivoclar Vivadent) and PM9 (Vita). For the objective evaluation were prepared five
specimens with thickness of 1, 2, 3 and 4 mm, which were radiographed with a
aluminum step and a dental section, using direct digital system. The radiographic
images were submitted to the reading of optical density. For subjective evaluation
were fabricated phantoms, simulating the back of the dental arches, in which two
teeth of each phantom received an inlay preparation, were restored with the studied
ceramics, and were x-rayed by the interproximal technique. These radiographs were
evaluated by three groups of examiners, dentists, radiologists, and prosthetists. To
analyze the chemical elements that provide radiopacity characteristics of the
materials, evaluation was performed by SEM and EDS. The results of objective
evaluation indicated significant differences between the radiopacity of the studied
ceramics. For 1 and 2 mm in thickness and the ceramics were all higher radiopacity
dentin and enamel below. Ceramics Noritake EX3 showed higher radiopacity in all
thicknesses. There was evident on the evaluations simulating clinical conditions, the
differences observed in the radiopacity of objective evaluation. The group of dentists
had a lower diagnostic accuracy when compared to groups of specialists, and
radiologists had the highest diagnostic accuracy for ceramics (0.57). Independent
group of evaluators was not possible to distinguish between X-ray and metal-free
ceramic composites. The result of evaluation of materials by SEM and EDS indicated
as possible elements radiopacifiers barium to ceramic Noritake EX-3 (2.19%), VM13
(1.04%), PM9 (0.70%) and IPS Empress II (0.70%) and zinc (4.50%) and cerium
(1.45%) for the ceramic IPS E.max ZirPress.
|
Page generated in 0.0552 seconds