Développement d’un prototype préindustriel de thermofrigopompe de petite à moyenne puissance / Development of a pre-industrial prototype of a heat pump for simultaneous heating and cooling small to medium heating power

Ghoubali, Redouane 28 November 2013 (has links)
Dans le contexte actuel de durcissement de la réglementation thermique visant à améliorer l’efficacité énergétique des bâtiments, il est nécessaire de repenser les installations de chauffage, de rafraîchissement et d’eau chaude sanitaire. Un système thermodynamique multifonction, appelé thermofrigopompe (TFP), produisant simultanément de l’énergie frigorifique et calorifique, semble alors une solution intéressante. L’emploi d’un fluide frigorigène à faible potentiel de réchauffement global (le GWP exprimé en émissions équivalentes de CO2), dans les machines frigorifiques, permet de répondre de manière efficace à la problématique de réduction des émissions de gaz à effet de serre. Cette thèse présente un prototype préindustriel de thermofrigopompe utilisant le propane comme fluide frigorigène. Le propane (R290) est intéressant d’abord pour son faible impact environnemental (ODP nul et GWP100ans =3) et pour ces performances énergétiques. Le prototype est le fruit d’une collaboration entre le Pôle cristal, centre technique froid et génie climatique de Dinan, et le laboratoire LGCGM de Rennes. Une nouvelle architecture du circuit frigorifique de la TFP est proposée avec une réduction significative du nombre d’électrovannes. Cette architecture permet une récupération efficace de la charge en fluide frigorigène lors des basculements entre les différents modes. Les besoins en chauffage, rafraîchissement et eau chaude sanitaire de trois types de bâtiments situés dans différents climats sont obtenus par simulation sous TRNSYS. La nature du bâtiment ainsi que le climat influencent fortement le caractère simultané des besoins. Un indicateur de besoins simultanés (TBS) est proposé afin d’identifier le bâtiment le plus adapté à une solution de production simultanée. Des essais en chambre climatique ont permis de valider le fonctionnement du prototype et de caractériser ses performances. Ces résultats expérimentaux ont servis à calibrer les modèles de composants et de machines frigorifiques pour chaque mode de fonctionnement développés avec le logiciel EES. Un bâtiment résidentiel collectif et un immeuble de bureaux ont été choisis dans l’étude comparative, afin d’évaluer l’influence de la nature des besoins sur les performances de la TFP. Les performances annuelles simulées par la méthode de corésolution (EES-TRNSYS) de la TFP sont comparées à une solution référence qui combine une PAC air/eau réversible pour le chauffage, et le rafraîchissement et un ballon thermodynamique pour l’ECS. Les résultats des simulations des performances saisonnières ont démontré que la piste des bureaux est intéressante dans le cas de zones nécessitant un fort besoin en rafraîchissement tout au long de l’année. / In the current context of hardening of thermal regulations to improve the energy efficiency of buildings, it is necessary to reconsider the heating, cooling and domestic hot water installations. A multifunctional heat pump system for simultaneous heating and cooling (HPS), which simultaneously produces cooling and heating energy, seems to be an interesting solution. The use of a refrigerant with low global warming potential (GWP expressed in equivalent emissions of CO2) in the refrigeration machinery can respond effectively to the problem of reducing greenhouse gas emissions. This work presents a pre-industrial prototype of HPS using propane as refrigerant. Propane (R290) is interesting firstly for its low environmental impact (zero ODP and GWP100 = 3) and for the energy performance. The prototype is the result of the collaboration between the Technical Centre for refrigeration and HVAC, Pôle Cristal and LGCGM laboratory. A new architecture of the refrigerant circuit of the HPS is proposed with a significant reduction in the number of valves. This architecture allows for efficient recovery of the refrigerant charge when switching between modes. The needs for heating, cooling and domestic hot water for three types of buildings in different climates are obtained by simulation using TRNSYS. The nature of the building and climate strongly influence the simultaneous nature of the needs. A ratio of simultaneous needs (RSN) is proposed to identify the most suitable building for the simultaneous production of heating and cooling energy. Climate chamber tests were used to validate the operation of the prototype and characterize its performance. These experimental results were used to calibrate the models of components and refrigerating machines for each operation developed with EES software. A collective residential building and an office building were selected in the comparative study, in order to evaluate the influence of the nature of the requirements on the performance of the HPS. Annual performance simulated by the co-solving method (EES-TRNSYS) of HPS is compared to a reference solution that combines a reversible air / water heat pump for heating, cooling and thermodynamic water heater for domestic hot water. The simulation results of the seasonal performance showed that the office building is interesting in the case of areas requiring a strong need for refreshment throughout the year.
2

Les mécanismes de maintien de l'information verbale en mémoire de travail / The mechanisms for maintenance of verbal information in working memory

Mora, Gérôme 09 September 2011 (has links)
La mémoire de travail est un système permettant de retenir des informations tout en réalisant simultanément un traitement. La répétition subvocale (Baddeley, 1986) et le rafraîchissement attentionnel (Barrouillet et al., 2007) sont deux mécanismes ayant été identifiés comme jouant un rôle dans le maintien de l’information verbale en mémoire de travail. Cependant, la nature exacte de la relation qu’entretiennent ces deux mécanismes a peu été étudiée et reste incertaine. Pour cette raison, le but de notre travail était dans un premier temps d’étudier la relation entre la répétition et le rafraîchissement. Dans plusieurs études réalisées chez le jeune adulte, l’utilisation de la répétition et l’utilisation du rafraîchissement ont été respectivement manipulées à travers la suppression articulatoire et la demande attentionnelle du traitement concurrent. Dans la continuité des travaux précédents de Camos, Lagner et Barrouillet (2009), les données de nos études permettent de conclure que les deux mécanismes sont indépendants et qu’ils peuvent être utilisés conjointement pour le maintien de mots. Des études supplémentaires suggèrent que la répétition et le rafraîchissement sont également indépendants chez l’enfant de 7-8 ans, mais qu’ils ne sont pas utilisés conjointement. Le second but visé par nos travaux était de tester la nature des représentations impliquées dans le maintien par répétition et par rafraîchissement. Pour cela, les propriétés phonologiques des mots à mémoriser ont été manipulées à travers la similarité phonologique et la longueur des mots, tandis que la mise en œuvre de la répétition et du rafraîchissement variait. Les données ont révélé que la répétition reposait sur les représentations phonologiques, alors que le rafraîchissement était indépendant de telles représentations. Les résultats de deux expériences exploratoires ont montré que le rafraîchissement ne reposait pas sur les connaissances à long terme (telles que la fréquence et la lexicalité) et laissent ouverte la question des représentations impliquées par ce mécanisme. Les données de nos recherches apportent des arguments en faveur des modèles de mémoire de travail qui supposent l’implication à la fois d’un mécanisme général et d’un mécanisme spécifique pour le maintien de l’information verbale. / Working memory is a system that allows to maintain information, while performing a concurrent processing. The subvocal rehearsal (Baddeley, 1986) and the attentional refreshing (Barrouillet et al., 2007) are two mechanisms identified as playing a role in maintenance of verbal information within working memory. However, the exact nature of the interplay of these two mechanisms was little studied and remains unclear. Therefore, the purpose of our work was first to investigate the interplay of rehearsal and refreshing. In several experiments performed with young adults, the use of rehearsal and refreshing were respectively manipulated through articulatory suppression and attentional demand of the concurrent processing. In line with previous works from Camos, Lagner and Barrouillet (2009), data from our studies allows to conclude that the two mechanisms are independent and could be used jointly to maintain words. Further studies indicated that rehearsal and refreshing were independent as well for 7-8 years old children, but were not used jointly. The second purpose addressed in our work was to investigate the nature of representations involved in maintenance by rehearsal and refreshing. Therefore, the phonological properties of words to remember were manipulated through phonological similarity and words’ length, while rehearsal and refreshing involvement varied. Data revealed that rehearsal relied on phonological representations, while refreshing was independent of such representations. Results from two explorative experiments revealed that refreshing did not rely on long-term knowledge (as frequency and lexicality) and leave open the question of the representations involved by this mechanism. The data from our research bring some arguments to models of working memory assuming the involvement of both general and specific mechanisms to maintain verbal information.
3

Étude expérimentale, modélisation et optimisation d'un procédé de rafraîchissement solaire à absorption couplé au bâtiment

Marc, Olivier 03 December 2010 (has links) (PDF)
Depuis quelques années, les exigences des occupants de bâtiments ont sensiblement changé. On observe en effet une demande de confort de plus en plus rigoureux en particulier en période estivale. Cette augmentation des besoins de climatisation induit un accroissement important de la consommation d'énergie électrique dans les bâtiments, dû à une utilisation majoritaire de climatiseurs à compression mécanique de vapeur. Dans ce contexte énergétique difficile, les systèmes de rafraîchissement solaire font partie des alternatives intéressantes aux systèmes de climatisation classiques, dans la mesure où l'énergie primaire est principalement consommée sous forme de chaleur et provenant du soleil donc gratuite. L'autre grand intérêt de ces procédés est que le besoin en rafraîchissement coïncide la plupart du temps avec la disponibilité du rayonnement solaire. La compréhension et le développement de cette technologie passent par une étude expérimentale avec la réalisation d'installations pilotes à échelle réelle dans le but d'acquérir une expérience concrète. C'est dans ce sens que notre laboratoire s'est proposé de mettre en place une plateforme expérimentale d'une puissance frigorifique de 30 kWf chargée de rafraîchir des locaux d'enseignement de l'Institut Universitaire Technologique de Saint Pierre à La Réunion. La première partie de ce manuscrit présente une analyse expérimentale de cette installation. Une seconde approche purement fondamentale a été envisagée avec l'élaboration de modèles numériques permettant de prédire le comportement de l'installation dans son ensemble. Ces modèles numériques décrits sous plusieurs niveaux de finesse, sont validés par les données expérimentales avant d'être utilisés, soit comme outils de pré‐dimensionnement pour les modèles à descriptions simplifiés, soit comme outil d'optimisation et d'analyse pour les modèles détaillés. Le modèle détaillé représentant notre plateforme expérimentale a permis de réaliser une optimisation du fonctionnement de l'installation et de proposer des améliorations pour réduire la consommation d'électricité et augmenter le coefficient de performance électrique global.
4

Étude du potentiel de rafraîchissement d'un système évaporatif à désorption avec régénération solaire

Maalouf, Chadi 13 December 2006 (has links) (PDF)
Le développement de la climatisation lié notamment à l'amélioration des conditions de vie entraîne l'augmentation de la consommation énergétique avec tous ses effets néfastes sur l'environnement. Il est donc urgent de trouver des alternatives viables à la climatisation traditionnelle. Si l'optimisation de la conception architecturale permet une nette amélioration des conditions de confort, elle peut s'avérer incompatible avec les besoins des architectes ou elle atteint ses limites pendant les périodes de canicule. Dans ce cas, le concept de rafraîchissement évaporatif couplé à l'énergie solaire constitue une alternative fiable et éprouvée qui contribue à la préservation de l'environnement.<br />Notre travail concerne l'étude du potentiel de rafraîchissement d'un système évaporatif par désorption couplé à une installation solaire. Ce système appelé « desiccant cooling » permet de réduire les consommations électriques et utilise l'énergie solaire qui est une énergie propre et gratuite.<br />la première partie de ce document est consacrée à l'étude des différentes technologies liées à ce système et à la description des différents composants en vue d'optimiser les choix pour la réalisation d'une installation expérimentale.<br />La deuxième partie est consacrée au développement d'un modèle de l'installation dessicante solaire. Ce modèle a été implémenté dans l'environnement modulaire SimSPARK, adapté à la résolution des systèmes d'équations non linéaires. Les simulations réalisées avec cet environnement ont permis d'étudier l'interaction système – bâtiment – climat. Les simulations saisonnières effectuées pour différentes villes françaises ont montré l'importance de la ventilation nocturne couplée à l'humidification pour réduire les besoins du système en énergie primaire. De plus, il s'est avéré que le système est adapté aux régions où l'humidité absolue dépasse rarement le seuil de 16g/kg d'air sec. <br />Enfin, la dernière partie de ce document confronte les résultats des simulations avec l'expérimentation in situ réalisée au sein de la première installation de ce type en France à la maison des énergies à Chambéry.
5

Étude expérimentale, modélisation et optimisation d'un procédé de rafraîchissement solaire à absorption couplé au bâtiment / Experimental investigation, modeling and optimisation of an absorption solar cooling system coupled to a building

Marc, Olivier 03 December 2010 (has links)
Depuis quelques années, les exigences des occupants de bâtiments ont sensiblement changé. On observe en effet une demande de confort de plus en plus rigoureux en particulier en période estivale. Cette augmentation des besoins de climatisation induit un accroissement important de la consommation d'énergie électrique dans les bâtiments, dû à une utilisation majoritaire de climatiseurs à compression mécanique de vapeur. Dans ce contexte énergétique difficile, les systèmes de rafraîchissement solaire font partie des alternatives intéressantes aux systèmes de climatisation classiques, dans la mesure où l'énergie primaire est principalement consommée sous forme de chaleur et provenant du soleil donc gratuite. L'autre grand intérêt de ces procédés est que le besoin en rafraîchissement coïncide la plupart du temps avec la disponibilité du rayonnement solaire. La compréhension et le développement de cette technologie passent par une étude expérimentale avec la réalisation d'installations pilotes à échelle réelle dans le but d'acquérir une expérience concrète. C'est dans ce sens que notre laboratoire s'est proposé de mettre en place une plateforme expérimentale d'une puissance frigorifique de 30 kWf chargée de rafraîchir des locaux d'enseignement de l'Institut Universitaire Technologique de Saint Pierre à La Réunion. La première partie de ce manuscrit présente une analyse expérimentale de cette installation. Une seconde approche purement fondamentale a été envisagée avec l'élaboration de modèles numériques permettant de prédire le comportement de l'installation dans son ensemble. Ces modèles numériques décrits sous plusieurs niveaux de finesse, sont validés par les données expérimentales avant d'être utilisés, soit comme outils de pré‐dimensionnement pour les modèles à descriptions simplifiés, soit comme outil d'optimisation et d'analyse pour les modèles détaillés. Le modèle détaillé représentant notre plateforme expérimentale a permis de réaliser une optimisation du fonctionnement de l'installation et de proposer des améliorations pour réduire la consommation d'électricité et augmenter le coefficient de performance électrique global. / In the last few years, thermal comfort research in summer has significantly increased the electricity consumption in buildings. This is mainly due to the use of conventional air conditioning systems operating with mechanical vapor compression. Solar cooling systems applied to buildings is an interesting alternative for reducing energy consumption in traditional mechanical steam compression air conditioning systems. But the understanding of this technology has to be refined through experimental study by setting up pilot plants. This study is a practical method to gain experience by analyzing all the processes behind solar cooling technology. For that purpose, our laboratory decided to install a solar cooling absorption system implemented in Reunion Island, located in the southern hemisphere. The particularity of this project is to achieve an effective cooling of classrooms, by a solar cooling system without any backup systems (hot or cold). The first part of this work presents an experimental study of this installation. Moreover, the study of these systems should have a closely purely fundamental approach including the development of numerical models in order to predict the overall installation performance. The final objective is to estimate cooling capacity, power consumption, and overall installation performance with relation to outside factors (solar irradiation, outside temperature, building loads). These numerical models described in several levels of accuracy, are validated by experimental data before being used either as tools for pre‐sizing models with simplified descriptions, either as a tool for optimization and analysis for the detailed models. The detailed model describing our experimental platform is used to carry out an optimization of pilot plant operation and to propose improvements to reduce electricity consumption and increase the overall electrical performance coefficient.
6

Modélisation, simulation dynamique, validation expérimentale et optimisation énergétique d’une unité de rafraîchissement solaire par absorption / Modelling, dynamic simulation, experimental validation and energetic optimization of an absorption solar air-cooling system

Anies, Guillaume 28 November 2011 (has links)
Le rafraîchissement solaire constitue une alternative intéressante à la climatisation réalisée au moyen de machines frigorifiques à compression mécanique de vapeur dont l’alimentation est électrique. Parmi les différentes solutions susceptibles de convenir, l’utilisation d’un cycle frigorifique tri-therme permet une valorisation de chaleur solaire en énergie frigorifique et constitue une voie prometteuse. Cependant, la variabilité des conditions aux limites (météorologiques notamment) et de ses influences temporelles sur le comportement global rend, à ce jour, très difficile, l’évaluation des performances énergétiques du système et plus encore son dimensionnement optimal, compte tenu de l’absence de moyen d’investigation. Cette thèse introduit la problématique du sujet et analyse les différentes technologies de rafraîchissement solaire envisageables à l'heure actuelle, afin d'expliquer la forte prépondérance des systèmes à absorption. Ensuite, pour répondre au problème, une nouvelle méthode de modélisation de ces machines permettant la prédiction des performances en régime transitoire est introduite et appliquée à quatre machines du marché. Puis, une installation pilotede rafraîchissement solaire est présentée dans le but d'analyser et de comprendre son comportement dynamique, afin d'identifier des voies d'optimisation. Enfin, les résultats expérimentaux de cette installation sont utilisés dans le but de développer et valider un outil complet d'analyse et d'optimisation des performances, c'est à dire depuis le champ de capteurs jusqu'à la distribution de froid. Cet outil de modélisation de systèmes de rafraîchissement solaire pourra ensuite être valorisé par la mise au point d'une méthodologie d'aide au dimensionnement de ce type d'installation, destiné au décideur ou à l'ingénieur. / The general context of the thesis is the solar cooling. This is an interesting alternative to conventional air conditioning systems, that is to say systems using mechanical vapour compression from electric power. Among the various solutions that may be suitable, the use of a refrigeration tri-thermal cycle is a promising issue. However, given the lack of means of investigation, the variability of the boundary conditions (including weather) and its temporal influences on the overall behaviour makes it very difficult, to evaluate the energy performance of the system nowadays, and even more difficult its optimal sizing. This thesis introduces the issue of the subject and analyzes the different state-of-the-art solar cooling technologies in order to explain the strong predominance of absorption systems. Then, to address the problem, a new method of modelling of these machines for the prediction of transient performance is introduced and applied to four machines on the market. Then, a solar cooling pilot is presented in order to analyze and understand its dynamic behaviour, to identify ways of optimization. Finally, the experimental results of this plant are used in order to develop and validate a completeanalysis and performance optimization methodology, i.e. from the collector field to the cooling distribution. This modelling tool for solar cooling systems can then be enhanced by the development of a methodology to help the design of this type of installation, for the decision maker or for the engineer.
7

Contribution au stockage d'énergie thermique en bâtiment : développement d'un système actif à matériaux à changement de phase

Ekomy Ango, Serge 24 November 2011 (has links) (PDF)
L'objectif de nos travaux de thèse est de concevoir, dimensionner et fabriquer un système actif à matériaux à changement de phase (MCP) pour le rafraîchissement et réchauffement de la maison Napévomo en région Aquitaine, ce dernier participant au concours Solar Décathlon (SDE2010). L'approche proposé a pour but de fournir au lecteur suffisamment de connaissant en stockage thermique à base de MCP pour entreprendre la conception d'un système de rafraîchissement et de réchauffement d'un bâtiment passif. La démarche utilisée consisté dans un premier temps à faire l'état de l'art des systèmes de stockage thermique à base de MCP et à établir un cahier des Charges du système à concevoir. Ces données ont amèné à proposer un modèle de calcul stationnaire basé sur une approche NUT-ε moyennant la caractérisation préalable des MCP pour dimensionner et concevoir le système. Le dimensionnement étant validé en fonction des pertes de charge et le COP (coefficient de performance). Le système est fabriqué à l'échelle 1. Il est composé de quatre échangeurs Air-MCP. Chaque échangeur renferme un amas contenant de MCP. Ils sont disposés en quinconces sur des colonnes de petits tubes. Un ensemble de dispositifs expérimentaux améliorent la conductivité des MCP ainsi que l'échange thermique entre le système et son environnement. Les essais réalisés sur l'un des échangeurs montrent des résultats encourageants. Ce dernier rafraîchit l'air en 7-8 heures et il permet de régénérer les MCP en 6 heures en moyenne. Lors du concours Solar Décathlon (SDE2010), le système installé dans la maison Napévomo a montré sa capacité à assurer le rafraîchissement de l'air ambiant durant les 6 jours de la démonstraction.
8

Analyse expérimentale et simulation de la ventilation naturelle mono-façade pour le rafraîchissement des immeubles de bureaux

Caciolo, Marcello 17 December 2010 (has links) (PDF)
L'application de la ventilation naturelle peut contribuer sensiblement à la réduction des besoins de climatisation et à l'amélioration du confort d'été dans les immeubles de bureaux. Dans cette thèse, une configuration simple de ventilation naturelle, c'est-à-dire la ventilation mono-façade, est étudiée expérimentalement et par simulation. Après avoir examiné les phénomènes qui contribuent au renouvellement de l'air, on évalue la validité et l'applicabilité des modèles existants afin de calculer le débit de ventilation, en comparant leurs résultats avec ceux d'une campagne de mesures effectuée dans une pièce expérimentale. Ensuite, on valide l'utilisation de la CFD, avec trois modèles différents de turbulence, pour la simulation de la ventilation naturelle mono-façade, par comparaison avec les essais. Les résultats d'un des modèles de turbulence (RANS RSM) sont utilisés pour l'établissement d'une nouvelle corrélation pour le calcul du débit de ventilation. Celle-ci apporte des améliorations par rapport aux corrélations existantes, en particulier lorsque l'ouverture est située sous le vent. Cette nouvelle corrélation est couplée à un modèle thermique dynamique afin d'évaluer le potentiel de rafraîchissement de la ventilation naturelle mono-façade dans des immeubles de bureaux neufs. En particulier, on étudie la réduction des besoins de climatisation dans des immeubles climatisés et le nombre d'heures d'inconfort en l'absence de climatisation. L'influence de plusieurs paramètres est considérée : climat, orientation, inertie, taux de surface vitrée, apports internes et stratégie de ventilation (diurne, nocturne et diurne + nocturne). Les simulations montrent des réductions importantes des besoins de refroidissement, entre 30 et 90%. Il est possible de se passer de climatisation, sans générer d'inconfort, à condition de privilégier une inertie lourde et de maitriser les apports internes et solaires.
9

Les mécanismes de maintien de l'information verbale en mémoire de travail

Mora, Gérôme 09 September 2011 (has links) (PDF)
La mémoire de travail est un système permettant de retenir des informations tout en réalisant simultanément un traitement. La répétition subvocale (Baddeley, 1986) et le rafraîchissement attentionnel (Barrouillet et al., 2007) sont deux mécanismes ayant été identifiés comme jouant un rôle dans le maintien de l'information verbale en mémoire de travail. Cependant, la nature exacte de la relation qu'entretiennent ces deux mécanismes a peu été étudiée et reste incertaine. Pour cette raison, le but de notre travail était dans un premier temps d'étudier la relation entre la répétition et le rafraîchissement. Dans plusieurs études réalisées chez le jeune adulte, l'utilisation de la répétition et l'utilisation du rafraîchissement ont été respectivement manipulées à travers la suppression articulatoire et la demande attentionnelle du traitement concurrent. Dans la continuité des travaux précédents de Camos, Lagner et Barrouillet (2009), les données de nos études permettent de conclure que les deux mécanismes sont indépendants et qu'ils peuvent être utilisés conjointement pour le maintien de mots. Des études supplémentaires suggèrent que la répétition et le rafraîchissement sont également indépendants chez l'enfant de 7-8 ans, mais qu'ils ne sont pas utilisés conjointement. Le second but visé par nos travaux était de tester la nature des représentations impliquées dans le maintien par répétition et par rafraîchissement. Pour cela, les propriétés phonologiques des mots à mémoriser ont été manipulées à travers la similarité phonologique et la longueur des mots, tandis que la mise en œuvre de la répétition et du rafraîchissement variait. Les données ont révélé que la répétition reposait sur les représentations phonologiques, alors que le rafraîchissement était indépendant de telles représentations. Les résultats de deux expériences exploratoires ont montré que le rafraîchissement ne reposait pas sur les connaissances à long terme (telles que la fréquence et la lexicalité) et laissent ouverte la question des représentations impliquées par ce mécanisme. Les données de nos recherches apportent des arguments en faveur des modèles de mémoire de travail qui supposent l'implication à la fois d'un mécanisme général et d'un mécanisme spécifique pour le maintien de l'information verbale.
10

Production-consumption system coordination by hybrid predictive approaches : application to a solar cooling system for buildings / Coordination Producteur-Consommateur par des approches prédictives hybrides : application au rafraîchissement solaire des bâtiments

Herrera Santisbon, Eunice 20 March 2015 (has links)
Garantir le confort thermique des bâtiments est directement lié à la consommation d'énergie. Dans les zones tropicales, les systèmes de refroidissement représentent l'un des postes les plus gourmands en énergie. Afin de réduire la consommation d'énergie mondiale, il est primordial d'améliorer l'efficacité de ces systèmes ou bien de développer de nouvelles méthodes de production de froid. Une installation de refroidissement solaire basé sur le cycle à absorption est une alternative pour réduire les émissions de gaz à effet de serre et la consommation d'électricité. Contrairement aux systèmes classiques de refroidissement à compression mécanique, la production de froid par absorption est un système complexe composé de plusieurs composants comme des panneaux solaires, un ballon de stockage, une tour de refroidissement et une machine à absorption. Outre le dimensionnement des composants, ce système complexe nécessite des actions de contrôle pour être efficace parce que la coordination entre le stockage d'eau chaude, la production et la consommation du froid est nécessaire. Le but de cette thèse est de proposer une structure producteur-consommateur d'énergie basée sur la commande prédictive (MPC). Le système de refroidissement par absorption solaire est considéré comme faisant partie de ce système de production-consommation d'énergie, le système de stockage d'eau chaude est le producteur et la machine à absorption qui distribue de l'eau froide au bâtiment est l'un des consommateurs. Pour que la structure de commande soit modulaire, la coordination entre les sous-systèmes est réalisée en utilisant une approche de partitionnement où des contrôleurs prédictifs locaux sont conçus pour chacun des sous-systèmes. Les contrôleurs des consommateurs calculent un ensemble de profils de demande d'énergie. Ces profils sont ensuite envoyés au contrôleur du producteur qui sélectionne le profil qui minimise le coût global. Dans une première partie, l'approche proposée est testée sur un modèle linéaire simplifié composé d'un producteur et plusieurs consommateurs. Dans une deuxième partie, un cas plus complexe est étudié. Un modèle simplifié d'un système de refroidissement à absorption est évaluée en utilisant l'outil de simulation TRNSYS. Le modèle de production n'est plus linéaire, il est décrit par un modèle non linéaire hybride qui augmente la complexité du problème d'optimisation. Les résultats des simulations montrent que la sous-optimalité induite par la méthode est faible. De plus, la performance de l'approche atteint les objectifs de commande tout en respectant les contraintes. / To guarantee thermal comfort in buildings is directly related to energy consumption. In tropical climates, cooling systems for buildings represent one of the largest energy consumers. Therefore, as energy consumption is a major concern around the world, it is important to improve the systems efficiency or seeking new methods of cooling production. A solar cooling installation based on the absorption cycle is an alternative to mitigate greenhouse gas emissions and electricity consumption. In contrast to conventional vapor-compression based cooling systems, the absorption cooling production involves a complex system composed of several components as collector panel, storage tank, cooling tower and absorption chiller. Besides the sizing of the components, this complex system requires control actions to be efficient as a coordination between hot water storage, cooling water production and consumption is necessary. The aim of this research is to propose a management approach for a production-consumption energy system based on Model Predictive Control (MPC). The solar absorption cooling system is seen as part of this production-consumption energy system where the hot water storage system is the producer and the chiller-building system is one of the consumers. In order to provide modularity to the control structure, the coordination between the subsystems is achieved by using a partitioning approach where local predictive controllers are developed for each of the subsystems. The consumer controllers compute a set of energy demand profiles sent to the producer controller which selects the profile that better minimize the global optimization cost. In a first part, the proposed approach is tested on a simplified linear model composed of one producer and several consumers. In a second part, a more complex case is studied. A simplified model of an absorption cooling system is evaluated using the simulation tool TRNSYS. The producer model is no longer linear, instead it is described by a nonlinear hybrid model which increases the complexity of the optimization problem. The simulations results show that the suboptimality induced by the method is low and the control strategy fulfills the objectives and constraints while giving good performances.

Page generated in 0.0911 seconds