Mesurer et améliorer le maintien en mémoire de travail chez les adultes jeunes et âgés : mesures comportementales et électrophysiologiques / Measuring and improving maintenance in working memory of young and old adults : behavioral and electrophysiological studies

Fanuel, Lison 22 November 2018 (has links)
Au cœur de la plupart de nos activités quotidiennes, la mémoire de travail est une fonction cognitive permettant de maintenir des informations à court terme tout en traitant d’autres informations (Atkinson & Shiffrin, 1968 ; Baddeley & Hitch, 1974). Différents modèles s’accordent sur le rôle central de l’attention dans la mémoire de travail, notamment via un mécanisme de maintienspécifique : le rafraîchissement attentionnel (Johnson, 1992). La présente thèse s’est intéressée à ce mécanisme encore assez mal connu chez des populations jeunes et âgées.La mémoire de travail de travail semble altérée dans le vieillissement et de récents travaux suggèrent que cette altération pourrait résulter d’un déficit du rafraîchissement attentionnel chez les adultes âgés (Hoareau, Lemaire, Portrat, & Plancher, 2016 ; Jarjat et al., 2018 ; Plancher, Boyer, Lemaire, & Portrat, 2017). Une mesure comportementale du rafraîchissement a été utilisée pour tester l’hypothèse du ralentissement du rafraîchissement attentionnel dans le vieillissement. Cependant, nos résultats suggèrent plutôt que les adultes âgés auraient des difficultés à initier un mécanisme de rafraîchissement, confortant l’hypothèse d’une altération (mais pas nécessairement un ralentissement) du rafraîchissement attentionnel dans le vieillissement.Afin de développer un moyen d’améliorer le rafraîchissement attentionnel des adultes jeunes et âgés, nous nous sommes ensuite tournées vers la théorie de l’attention dynamique (Jones, 1976 ; Jones & Boltz, 1989 ; Large & Jones, 1999). Issue des travaux sur la cognition musicale, la théorie de l’attention dynamique propose que la distribution des ressources attentionnelles puisse être guidée par une structure temporelle externe et régulière, résultant en une meilleure allocation des ressources attentionnelles et une amélioration des traitements perceptifs et cognitifs. Puisque le rafraîchissement est un mécanisme attentionnel, nous avons fait l’hypothèse que la présence de régularités temporelles durant le maintien en mémoire de travail pourrait le rendre plus efficace. Nos études révèlent que la présence d’un rythme auditif régulier durant la rétention d’informationsaméliore, en effet, le rafraîchissement attentionnel chez les adultes jeunes et certains les adultes âgés qui ont de bonnes capacités d’inhibition.Puisque le rafraîchissement attentionnel a été étudié jusqu’à maintenant par le biais de mesures comportementales indirectes, nous avons cherché à identifier une mesure plus directe de ce mécanisme via une mesure électrophysiologique du rafraîchissement. Les mesures électroencéphalographiques effectuées durant le maintien en mémoire de travail suggèrent que les oscillations neurales, particulièrement dans les bandes de fréquence bêta, sont impliquées dans lerafraîchissement attentionnel.Nos résultats confortent l’intérêt d’utiliser des techniques interventionnelles musicales et/ou rythmiques pour pallier les altérations de la mémoire de travail. Les travaux de cette thèse offrent de nouvelles perspectives pour (1) l’étude de l’altération du maintien en mémoire de travail dans le vieillissement et (2) l’effet bénéfique de la présence d’une structure temporelle régulière sur les oscillations neurales durant le maintien en mémoire de travail. À plus long-terme, l’utilisation del’électroencéphalographie devrait permettre de mieux comprendre l’impact de ces interventions sur le fonctionnement de la mémoire de travail. / Working memory is at the core of most of our daily-life activities. This cognitive function allows maintaining information at short-term while processing other information (Atkinson & Shiffrin, 1968 ; Baddeley & Hitch, 1974). Several models have agreed on the central role of attention in working memory, in particular via a specific maintenance mechanism: attentional refreshing (Johnson, 1992). The present PhD thesis investigated this mechanism, which is still not well known, in young and old adults.Working memory seem to be impaired in aging, and recent studies have suggested that this impairment could be due to a deficit of attentional refreshing in old adults (Hoareau et al., 2016 ; Jarjat et al., 2018 ; Plancher et al., 2017). A behavioral measure of refreshing was used to test the hypothesis of a slowing down of refreshing in aging. However, our results rather suggest an agerelated deficit in the initiation of attentional refreshing and are thus in line with the hypothesis of an impairment (but not necessarily a slowing) of attentional refreshing in aging.To develop a way to improve attentional refreshing in young and old adults, we focused on the dynamic attending theory (Jones, 1976 ; Jones & Boltz, 1989 ; Large & Jones, 1999). Based on music cognition research, the dynamic attending theory proposes that the distribution of attentional resources can be guided in the presence of an external and temporally regular structure, resulting in a better allocation of attentional resources and enhanced perceptual and cognitive processing. As refreshing is an attentional mechanism, we hypothesized that this mechanism might benefit from the presence of temporal regularities during maintenance in working memory. Our studies revealed that the presence of an auditory, temporally regular rhythm during retention benefits indeed attentional refreshing in young adults and some in old adults who have with greater inhibition capacities.As attentional refreshing has been investigated up to now only with indirect behavioral measures, we aimed for a more direct assessment of this mechanism by investigating electrophysiological measures of refreshing. Electroencephalographical recordings during maintenance in working memory suggested that neural oscillations, especially in the beta-bandfrequency range, are involved in attentional refreshing.Our findings strengthen the interest of musical and/or rhythmical intervention techniques aiming to overcome deficits in working memory. The research of this thesis offers new perspectives for studying (1) age-related impairments of maintenance in working memory in aging and (2) the beneficial effect of the presence of a temporally regular structure on neural oscillations duringmaintenance in working memory. In a long-term perspective, electrophysiology could be helpful provide a better understanding of the impact of these techniques on working memory functioning.
12

Etudes des mécanismes de maintien en mémoire de travail chez les personnes jeunes et âgées : approches computationnelle et comportementale basées sur les modèles TBRS* et SOB-CS / Study of the maintenance mechanisms in working memory with young and older people : computational and behavioral approach based on the TBRS* and SOB-CS models

Hoareau, Violette 19 December 2017 (has links)
La mémoire de travail est un système cognitif essentiel à notre vie quotidienne. Elle nous permet de conserver momentanément des informations dans le but de réaliser une tâche cognitive. Une des caractéristiques principales de ce type de mémoire est d’être limitée en capacité. Les raisons de cette limitation sont largement débattues dans la littérature. Certains modèles considèrent qu'une cause principale de l'oubli en mémoire de travail est l'existence d'un déclin temporel passif de l'activation des représentations mnésiques alors que d'autres modèles supposent que les interférences entre les informations suffisent à expliquer la capacité limitée de cette mémoire. Deux modèles computationnels ont été proposés récemment (TBRS* et SOB-CS) et illustrent parfaitement ce débat. En effet, ils décrivent de manière très différente ce qui se passe au cours d’une tâche de mémoire de travail impliquant à la fois la mémorisation et le traitement d’informations. En plus de s'opposer sur les causes de l’oubli, ils proposent des processus de maintien en mémoire de travail distincts : le rafraîchissement des informations pertinentes selon TBRS* versus la suppression des informations non pertinentes selon SOB-CS. Les travaux de cette thèse se sont organisés autour de deux objectifs principaux. Premièrement, cette thèse a porté sur l’étude de ces deux modèles et leur mécanisme de maintien. Pour cela, nous avons réalisé des expériences comportementales utilisant la tâche d’empan complexe afin de tester des hypothèses précises de ces modèles. Deuxièmement, nous avons étudié, à l'aide des modèles computationnels, les causes des déficits de mémoire de travail observés chez les personnes âgées, dans le but, à long terme, de créer ou d'améliorer les outils de remédiation. Concernant le premier objectif, les différents résultats d’études ont montré une discordance entre le comportement humain et les simulations. En effet, TBRS* et SOB-CS ne permettent pas de reproduire un effet positif du nombre de distracteurs contrairement à ce qui a été observé expérimentalement. Nous proposons que cet effet positif, non prédit par les modèles, est relié à la mémorisation à long terme non prise en compte dans ces deux modèles. Concernant le deuxième objectif, les résultats comportementaux suggèrent que les personnes âgées auraient principalement des difficultés à rafraîchir les traces mnésiques et à stabiliser les informations à long terme au cours d’une tâche d’empan complexe. Dans l’ensemble, les résultats de cette thèse suggèrent d'approfondir les recherches concernant les liens entre les mécanismes de maintien en mémoire de travail et la mémorisation à long terme, par exemple en proposant un nouveau modèle computationnel permettant de rendre compte de nos résultats. Au-delà des avancées concernant la compréhension du fonctionnement de la mémoire de travail, cette thèse montre également que l’utilisation de modèles computationnels revêt un caractère particulièrement pertinent pour l'étude d'une théorie ainsi que pour la comparaison de différentes populations. / Working memory is a cognitive system essential to our daily life. It allows us to temporarily store information in order to perform a cognitive task. One of the main features of this type of memory is to be limited in capacity. The reasons for this limitation are widely debated in the literature. Some models consider that a main cause of forgetting in working memory is the existence of a passive temporal decay in the activation of memory representations whereas other models assume that interference between information are sufficient to explain the limited capacity of this memory. Two computational models have recently been proposed (TBRS* and SOB-CS) and they perfectly illustrate this debate. Indeed, they both describe differently what happens during a working memory task involving both storage and information processing. In addition to opposing the causes of forgetting, they propose separate maintenance processes: refreshing relevant information according to TBRS* versus removing irrelevant information according to SOB-CS. This thesis was organized around two main objectives. First, we focused on the study of these two models and their maintenance mechanisms. To do so, we performed behavioral experiments using the complex span task to test specific hypotheses of these models. Second, using computational models, we investigated the causes of working memory deficits observed in the elderly, with the aim, in the long term, of creating or improving remediation tools. Regarding the first objective, results showed a discrepancy between human behavior and simulations. Indeed, TBRS* and SOB-CS did not reproduce a positive effect of the number of distractors contrary to what has been observed experimentally. We propose that this positive effect, not predicted by the models, is related to the long-term storage not taken into account in these two models. Regarding the second objective, the behavioral results suggest that older people would have difficulty mainly in refreshing memory traces and in stabilizing information in the long term during a complex task. Overall, the results of this thesis suggest to deepen the research on the links between the maintenance mechanisms and the long-term storage, for example by proposing a new computational model accounting for our results. Beyond advances in understanding the functioning of working memory, this thesis also shows that the use of computational models is of particular relevance for the study of a theory as well as for the comparison of different populations.
13

Etude d'un système innovant de rafraîchissement basse consommation pour le bâtiment / Study of an innovative low energy cooling system for buildings

Leroux, Guilian 21 October 2016 (has links)
Pour faire face à la forte augmentation de la consommation en climatisation et la consommation électrique associée, il est nécessaire de développer des systèmes de rafraîchissement basse consommation de bâtiment. Ce travail propose un nouveau système de rafraîchissement qui se veut économe en énergie, peu coûteux et simple à installer. Il associe les techniques de dissipation de chaleur par évaporation, rayonnement vers le ciel et géothermie. Ce système est constitué d'un réservoir poreux installé en extérieur et d'un réservoir de stockage placé dans le vide sanitaire. Lorsque le bâtiment a besoin de rafraîchissement, une pompe puise de l'eau fraîche dans le stockage, la fait passer dans le plancher rafraîchissant pour absorber la chaleur excédentaire du bâtiment puis stocke l'eau dans le réservoir poreux placé à l'extérieur. Le réservoir poreux refroidit l'eau qu'il contient par évaporation, rayonnement vers le ciel puis se vide dans le stockage. Le réservoir de stockage installé dans le vide sanitaire se refroidit aussi en continu grâce au contact direct avec le sol. Les propriétés poreuses et la géométrie du réservoir poreux influent fortement sur ses performances de refroidissement. Une étude paramétrique menée avec un modèle numérique simulant les transferts hydriques et thermique permet de choisir un réservoir adéquat pour cette application. Un réservoir poreux donnant de bonnes performances (70 W/m2 de puissance évaporative) a été identifié. Le système de rafraîchissement a été installé et testé expérimentalement sur une maison à échelle réelle à Bordeaux. Mis en service durant l'été 2015, le système a fonctionné de façon autonome durant 44 jours. L'utilisation de ce système a permis de maintenir durant la période de test un très bon confort thermique à l'intérieur d'un bâtiment expérimental bien isolé, non ventilé, avec des apports solaires, tout en ayant une consommation électrique faible (le COP moyen du système est de 20.8). Un modèle numérique du système complet a été développé sous Modelica, calibré sur les mesures expérimentales puis couplé à un modèle de bâtiment. Les résultats de simulation montrent que l'installation de ce système améliore nettement le confort intérieur du bâtiment sur l'ensemble de l'été pour toutes les configurations testées (climat, gestion des voletsdots). Un système aux dimensions optimisées (avec un stockage de 2.2 m3 et un réservoir poreux de 0.215 m3), installé sur une maison individuelle type RT2012 de 100 m2 à Bordeaux, fonctionne avec un COP moyen de 24 et permet de maintenir un bon niveau de confort à l'intérieur du bâtiment tout l'été. / To face the dramatic increase of energy consumption due to air conditioning use in buildings, new low energy consumption systems need to be developed. This work proposes a new cooling system which aims to be energy efficient, cheap and easy to install. This system takes advantage of evaporation cooling, ground earth cooling and sky radiative cooling techniques. The two main components of this new system are a porous tank set outside and a storage tank set in the basement of the building. When the inside house temperature exceeds the comfort temperature, cool water passes from the storage tank through the cooling floor, removes heat from the building and is then send to the porous tank. The water contained in the porous tank is cooled down due to evaporation and radiative effects and then flows back to the storage. The storage tank installed in the basement enables further cooling of the water thanks to direct contact with the ground. Porous properties and geometry of the tank have a great influence on the cooling performances of the tank. A heat and mass transfer model has been developed to simulate the thermal and hydric behavior of the tank. This model has been used to choose an appropriate tank. A tank giving good performances (70 W/m2 of evaporative power) is identified. The complete cooling system has been installed on a house in Bordeaux and tested at real scale during an experimental campaign. The system worked for 44 days during summer 2015 and allowed to maintain a very good thermal comfort level in the experimental building (insulated, with solar load and without ventilation). Its very low electricity needs brings the average coefficient of performance of the system to 20.8. A numerical model of the system has been developed, calibrated with experimental data and coupled with a building model. Simulation results show that for all tested configurations (climate, shading…), the system clearly improves the thermal comfort in the building. Optimized sizing, keepinp reasonnable tank sizes (storage and evaporator volumes of 2.2 m3 and 0.215 m3 respectively), shows that this system works with an average COP of 24 and maintains a good comfort level in an individual house of 100 m2 located in Bordeaux.
14

Etude du confort thermique dans l'habitat par des procédés géo-héliothermiques / Study of the thermal comfort in building by geo- solar thermal processes

Benzaama, Mohammed Hichem 14 May 2017 (has links)
Ce travail s'inscrit dans le cadre de la recherche des solutions d’économie d'énergie du bâtiment tout en utilisant des sources naturelles et renouvelables (Energie solaire pour le chauffage et la géothermie pour le rafraîchissement). Il est nul besoin de rappeler que l'Algérie dispose d'un potentiel énergétique hélio géothermique important. Dans ce travail de thèse on s'intéresse particulièrement à l'étude du confort thermique (hiver et été) dans l'habitat alimenté par un plancher hydraulique réversible. Pour mener à bien cette étude, nous disposons d'un gisement solaire important d'une part et d'autre part d'un dispositif expérimental à échelle réelle. Une pièce munie d'un plancher hydraulique réversible (chauffant ou rafraichissant) est instrumentée. Une citerne de stockage enfuie à quelques mètres de la surface du sol afin de bénéficier du rafraichissement géothermique. Un service d'asservissement permettant la régulation du système en fonctionnement mode chauffage ou mode rafraichissement. Plusieurs sondes de mesures reliées à une station d'acquisition qui est reliée à un ordinateur permettent le suivi des évolutions de températures. La modélisation de la structure de l'enveloppe de la cellule et l'évolution de la température de l'air intérieur et celle des parois sont réalisées sous le logiciel TRNSYS. A l'aide des résultats obtenus par TRNSYS, logiciel FLUENT nous a permis de modéliser la tache solaire et son influence sur le plancher chauffant sous les conditions climatiques de la ville d'Oran.Après validation, la simulation numérique est utilisée pour étudier le comportement thermique de la cellule, les performances énergétiques du plancher réversible et le calcul des économies d'énergie que l'on pourrait réaliser avec de tels systèmes. / This work is part of the search for energy saving solutions in the building industry while using natural and renewable sources, such as solar energy for heating and geothermal energy for refreshment. There is no need to recall that Algeria has a very large geothermal gravitational energy potential in view of its geographical position.In this thesis work, we are particularly interested in the study of thermal comfort in the case of a housing powered with a reversible hydraulic floor (heating and cooling).To carry out this study, as we can see Algeria have an important solar field and on the other hand we use an experimental system representing a real scale local. To do this, a room with a reversible hydraulic floor (heated or refreshing) is instrumented. A storage tank buried in the ground at few meters from the ground surface is used for thegeothermal refreshment during the warm periods. A service system allows us to regulate the system in heating or cooling mode. Several measuring probes used are connected to an acquisition station which is connected to a computer for monitoring of temperature évolutions.The modeling of the structure of the cell envelope is carried out under the TRNSYS software. With this, we have access to evolutions of the temperatures of the indoor air and to that of the walls. These results obtained by TRNSYS are used in a second step as input data for the FLUENT software. This allows us to model the solar spot and its influence on the heating floor under the climatic conditions of the city of Oran.After validation, numerical simulation is used to study the thermal behavior of the cell, the energy performance of the reversible floor and the calculation of the energy savings that could be achieved with such systems.
15

Système intégré de rafraîchissement d’air pour le bâtiment à base de matériaux à changement de phase / Air-cooling integrated system in building using phase change material

Rouault, Fabien 10 April 2014 (has links)
Les systèmes de rafraîchissement d'air basés sur des échangeur-stockeurs composés de Matériaux à Changement de Phase (MCP) sont une alternative possible aux systèmes de climatisation pour le confort d'été dans les bâtiments. Toutefois, les performances de tels systèmes de rafraîchissement sont étroitement liées aux conditions climatiques et aux configurations des bâtiments à rafraîchir. L'objectif de ce travail de thèse est de développer un outil d'aide à la conception permettant un pré-dimensionnement optimal de systèmes de rafraîchissement d'air utilisant des MCP dès le stade de la conception préliminaire. Un modèle thermique dynamique simulant le comportement d'un échangeur-stockeur air/MCP est donc développé puis couplé à une plateforme logicielle de simulation thermique dynamique du bâtiment. Les modèles d'échangeur-stockeurs et de co-simulation sont validés à l'aide d'expériences menées sur deux prototypes d'échangeur-stockeur et la plateforme expérimentale de maison à énergie positive NAPEVOMO. Enfin un premier outil d'aide à la conception utilisant un algorithme d'optimisation est développé pour définir une configuration optimale de système maintenant le confort estival dans la maison NAPEVOMO. / Air-cooling systems using latent heat thermal energy storage (LHTES) are potential alternatives to air-conditioners for summer climate control in buildings. However, the performances of such systems are tightly linked to weather conditions and the configuration of the building to be cooled. The aim of this doctoral work is to develop a design support tool allowing optimally dimensioning an air-cooling system using phase change material at the preliminary design stage. A dynamic thermal model, simulating the behaviour an LHTES device exchanging with air, is developed and coupled with a building performance program. The LHTES and the co-simulation models are validated by comparison with experiments carried out on two prototypes of LHTES device and the experimental platform of zero energy building NAPEVOMO. Finally, a first design support tool using genetic algorithm is developed to define the optimal configuration of an air-cooling system for the summer comfort in « NAPEVOMO » house.
16

Contribution à l'étude d'un échangeur de chaleur air-sol (puits canadien) pour le rafraîchissement de l'air sous le climat chaud et semi-aride de Marrakech / Contribution to the study of an earth to air heat exchanger for air cooling in hot and semi-arid climate of Marrakech

Khabbaz, Mohamed 17 December 2016 (has links)
La conception des bâtiments à faible consommation d'énergie est devenue un enjeu très important à travers le monde afin de minimiser la consommation d'énergie et les émissions de gaz à effet de serre associés. Au Maroc, le secteur du bâtiment représente 25% de la consommation énergétique finale du pays avec 18% réservée au résidentiel et 7% pour le tertiaire (ADEREE 2011). L'intégration de systèmes passifs ou semi-passifs de rafraîchissement/chauffage dans le bâtiment est désormais indispensable pour la réduction de la consommation énergétique tout en améliorant le confort thermique. Un de ces systèmes est l’échangeur air-sol (EAHX). Le principe du rafraîchissement à l'aide de l’échangeur air-sol est bien établi, mais le comportement d'un tel système dépend des conditions climatiques et de la nature du sol. L’échangeur air-sol étudié est installé dans une maison type villa située dans la banlieue de Marrakech. Un monitoring de ce système a été réalisé durant l’été 2013 à travers un suivi des températures et de l'humidité durant 39 jours. Les résultats montrent que l’échangeur air-sol est un système adapté pour le rafraîchissement de l’air dans les bâtiments à Marrakech, puisqu’il procure une température de soufflage quasi-constante d’environ 22°C pour le débit 244 m3/h et 25°C pour le débit de 312m3/h, avec une humidité relative autour de 50 % alors que la température extérieure dépasse 40°C. Le modèle mathématique choisi et l’outil de simulation associé, Type 460 opérant sous le logiciel commercial TRNSYS, sont analysés et validés par confrontation avec les résultats expérimentaux. Cette confrontation a montré une excellente concordance, avec un écart absolu moyen entre la mesure et la simulation toujours inférieur à 0,5°C et décroit à 0,2°C à la sortie de tube enterré. La validation de l’outil de simulation avec un échangeur air-sol enterré dans un sol soumis à conditions météorologiques extérieures n’a pas été réalisée auparavant. D'autre part, les simulations dynamiques de l’échangeur air-sol sont réalisées en fonctionnement continu, avec 1 et 3 tubes durant la période chaude de l’année (mai-septembre). Les résultats montrent que le système procure une température à la sortie de tube enterré de 25,1°C (1 tube) et 26 °C (3 tubes). Il en résulte une capacité de refroidissement de 58w/m2 (1 tube) et 55w/m2 (3 tubes) pour une température à l’entrée de 44,6°C. Une étude de sensibilité, utilisant la méthode de Sobol, de la performance thermique de l'échangeur durant la saison chaude (mai-septembre) a permis de dégager les paramètres les plus influents. Par la suite, une étude paramétrique complète sur l’énergie sensible totale perdue par l’air lors dans son passage dans l’échangeur air-sol est réalisée en fonction des paramètres les plus influents déterminés auparavant. / The low energy buildings tendency has become a major worldwide key to minimize energy consumption and greenhouse gas emissions issues. In Morocco, the building sector represents 25% of the total final energy consumption, whereas 18% is dedicated for residential and 7% for the tertiary sector (ADEREE 2011). The integration of passive or semi-passive for cooling/heating purposes into buildings is an essential act for reducing energy consumption while improving thermal comfort. One of these systems is the Earth to Air Heat Exchanger (EAHX). Its principle to use the ground-coupled heat exchanger for cooling is well established, but the behavior of such a system depends on the climate and the soil, which influences the choice of design parameters of this system. We performed a numerical and experimental study on the thermal performance of an Earth to air heat exchanger installed in a villa type house in the suburbs of Marrakech. A monitoring survey was conducted during the summer period of 2013, to acquire temperature and humidity measurements for 39 days. The results show that the earth to air heat exchanger is a system more adapted to refresh the air in buildings in Marrakech, as it provides a quasi constant air temperature of approximately 22°C for flow 244 m3/h and 25°C for flow of 312 m3/h, with relative humidity that is around 50% when the outside temperature exceeds 40°C. The mathematical model chosen and the associated simulation tool used is Type 460 operating under the TRNSYS commercial software, analyzed and validated by comparison with experimental results. This comparison showed excellent agreement, with an average absolute difference between the measurement and simulation that is always lower than 0.5°C and 0.2°C as it decreases at the output of the buried pipe. On the other hand, dynamic simulations of the EAHX using TRNSYS software (TYPE 460) were performed with one pipe or three pipes continuously running. The achieving specific cooling capacity is 58 W/m2 (one pipe) and 55 W/m2 (three pipes) obtained for air temperatures of 25 °C and 26 °C respectively, at the EAHX outlet and 44.6 °C at its inlet. A sensitivity analysis, using the method of Sobol, of the thermal performance of the earth air heat exchanger (EAHX) in the hot season (May-September) has identified the most influential parameters. Thereafter, a complete parametric study on the total sensible energy lost through the air when in passing through the air-ground heat exchanger is made based on the most influential parameters determined previously.
17

Production-consumption system coordination by hybrid predictive approaches : application to a solar cooling system for buildings / Coordination Producteur-Consommateur par des approches prédictives hybrides : application au rafraîchissement solaire des bâtiments

Herrera Santisbon, Eunice 20 March 2015 (has links)
Garantir le confort thermique des bâtiments est directement lié à la consommation d'énergie. Dans les zones tropicales, les systèmes de refroidissement représentent l'un des postes les plus gourmands en énergie. Afin de réduire la consommation d'énergie mondiale, il est primordial d'améliorer l'efficacité de ces systèmes ou bien de développer de nouvelles méthodes de production de froid. Une installation de refroidissement solaire basé sur le cycle à absorption est une alternative pour réduire les émissions de gaz à effet de serre et la consommation d'électricité. Contrairement aux systèmes classiques de refroidissement à compression mécanique, la production de froid par absorption est un système complexe composé de plusieurs composants comme des panneaux solaires, un ballon de stockage, une tour de refroidissement et une machine à absorption. Outre le dimensionnement des composants, ce système complexe nécessite des actions de contrôle pour être efficace parce que la coordination entre le stockage d'eau chaude, la production et la consommation du froid est nécessaire. Le but de cette thèse est de proposer une structure producteur-consommateur d'énergie basée sur la commande prédictive (MPC). Le système de refroidissement par absorption solaire est considéré comme faisant partie de ce système de production-consommation d'énergie, le système de stockage d'eau chaude est le producteur et la machine à absorption qui distribue de l'eau froide au bâtiment est l'un des consommateurs. Pour que la structure de commande soit modulaire, la coordination entre les sous-systèmes est réalisée en utilisant une approche de partitionnement où des contrôleurs prédictifs locaux sont conçus pour chacun des sous-systèmes. Les contrôleurs des consommateurs calculent un ensemble de profils de demande d'énergie. Ces profils sont ensuite envoyés au contrôleur du producteur qui sélectionne le profil qui minimise le coût global. Dans une première partie, l'approche proposée est testée sur un modèle linéaire simplifié composé d'un producteur et plusieurs consommateurs. Dans une deuxième partie, un cas plus complexe est étudié. Un modèle simplifié d'un système de refroidissement à absorption est évaluée en utilisant l'outil de simulation TRNSYS. Le modèle de production n'est plus linéaire, il est décrit par un modèle non linéaire hybride qui augmente la complexité du problème d'optimisation. Les résultats des simulations montrent que la sous-optimalité induite par la méthode est faible. De plus, la performance de l'approche atteint les objectifs de commande tout en respectant les contraintes. / To guarantee thermal comfort in buildings is directly related to energy consumption. In tropical climates, cooling systems for buildings represent one of the largest energy consumers. Therefore, as energy consumption is a major concern around the world, it is important to improve the systems efficiency or seeking new methods of cooling production. A solar cooling installation based on the absorption cycle is an alternative to mitigate greenhouse gas emissions and electricity consumption. In contrast to conventional vapor-compression based cooling systems, the absorption cooling production involves a complex system composed of several components as collector panel, storage tank, cooling tower and absorption chiller. Besides the sizing of the components, this complex system requires control actions to be efficient as a coordination between hot water storage, cooling water production and consumption is necessary. The aim of this research is to propose a management approach for a production-consumption energy system based on Model Predictive Control (MPC). The solar absorption cooling system is seen as part of this production-consumption energy system where the hot water storage system is the producer and the chiller-building system is one of the consumers. In order to provide modularity to the control structure, the coordination between the subsystems is achieved by using a partitioning approach where local predictive controllers are developed for each of the subsystems. The consumer controllers compute a set of energy demand profiles sent to the producer controller which selects the profile that better minimize the global optimization cost. In a first part, the proposed approach is tested on a simplified linear model composed of one producer and several consumers. In a second part, a more complex case is studied. A simplified model of an absorption cooling system is evaluated using the simulation tool TRNSYS. The producer model is no longer linear, instead it is described by a nonlinear hybrid model which increases the complexity of the optimization problem. The simulations results show that the suboptimality induced by the method is low and the control strategy fulfills the objectives and constraints while giving good performances.
18

Contribution à l'étude numérique de la ventilation naturelle dans des cavités ouvertes par la simulation des grandes échelles. Application au rafraîchissement passif des bâtiments

Brangeon, Boris 26 October 2012 (has links) (PDF)
Contexte du sujet : La climatisation est un poste de dépense énergétique important dans le secteur du bâtiment, qui pourrait être réduit de manière drastique par l'utilisation de systèmes passifs de rafraîchissement. Dans les climats chauds et humides, le rafraîchissement passif des bâtiments est une solution éprouvée, qui s'ordonne autour de quatre principes : minimiser les apports de chaleur interne et externe, apporter de l'inertie au bâtiment, humidifier l'air et assurer une bonne ventilation pour favoriser les échanges convectifs. Objectifs : La description des transferts thermo-convectifs (évaluation des débits massiques, des transferts de chaleur) mis en jeu dans des cavités ouvertes (pièces avec ventilation traversante, cheminées solaires, doubles peaux, espaces sous-toiture) est encore mal connue et constitue un enjeu pour l'amélioration des systèmes passifs. L'étude de ces phénomènes peut être évaluée par la mécanique des fluides numérique. Les objectifs de ce travail de thèse sont : de réaliser des simulations numériques fines du comportement thermo-aéraulique dans des configurations typiques de systèmes passifs en climat tropical humide, afin d'améliorer nos connaissances sur la ventilation naturelle, d'approfondir et d'apporter des éléments de réponses en ce qui concerne le choix des conditions limites numériques à appliquer pour les systèmes ouverts. Modélisation numérique : L'approche numérique adoptée dans ce travail, pour étudier la convection naturelle turbulente, est la simulation des grandes échelles (SGE ou LES en anglais). Cette approche se situe à mi-parcours entre la méthode de calcul direct et la réso- lution des équations moyennées en temps, de type RANS. L'avantage d'une telle technique est la réduction appréciable du nombre de points de discrétisation nécessaire par rapport à ce- lui exigé par la méthode de calcul direct, tout en conservant l'aspect dynamique des écoulements. Résultats : Les résultats obtenus lors de ce travail concernent l'étude des conditions limites dynamiques à imposer pour des géométries ouvertes avec une SND et l'application de la SGE à différentes configurations de cavités ouvertes en régime turbulent, afin de caractériser les champs de température et de vitesse et d'en déduire les grandeurs intégrales d'intérêt (débit massique, débit enthalpique, renouvellement d'air, ...). Les résultats de ces calculs ont été comparés soit à d'autres résultats numériques dans le cadre de benchmarks nationaux (benchmark numérique AmeTh et ADNBâti) ou à des résultats expérimentaux.
19

Etude expérimentale et numérique d'une thermofrigopompe de petite à moyenne puissance à équilibrage sur air

Byrne, Paul 23 November 2009 (has links) (PDF)
Les nouveaux bâtiments sont sujets à un renforcement de l'isolation thermique, à une augmentation des surfaces vitrées et à un accroissement des apports internes dus à des appareils électriques de plus en plus nombreux (ordinateurs, électroménager...). Cette tendance conduit à une diminution des demandes de chauffage mais peut engendrer des demandes de rafraîchissement en mi-saison et en période estivale. Les besoins en chauffage et en rafraîchissement deviennent plus équilibrés sur une journée et sur l'année en général. De plus, l'eau chaude sanitaire (ECS) occupe une place de moins en moins négligeable dans les besoins énergétiques totaux, ce qui provoque une simultanéité partielle des besoins en chaud et en froid dès que des demandes de rafraîchissement apparaissent. Une thermofrigopompe (TFP), machine frigorifique produisant de l'énergie calorifique et frigorifique de manière simultanée, associée à un stockage tampon d'énergie devient alors une solution intéressante. La TFP de petite à moyenne puissance est un système de production d'eau chaude et d'eau froide utilisant l'air comme source gratuite, destiné au chauffage, au rafraîchissement et à la production d'ECS pour des bâtiments du secteur résidentiel et du petit tertiaire. Elle présente plusieurs spécificités techniques dans la conception du circuit frigorifique, dans la gestion des modes de fonctionnement et des séquences de dégivrage. L'ajustement des productions de chaud et de froid aux charges du bâtiment s'effectue grâce à l'utilisation d'un échangeur d'équilibrage sur air extérieur fonctionnant soit en condenseur, soit en évaporateur. En période de chauffage, cette TFP offre également la possibilité de stocker une certaine quantité d'énergie sur la boucle d'eau froide à l'aide d'un sousrefroidisseur. Cette énergie stockée est utilisée en temps différé à l'évaporateur à eau afin d'améliorer les performances par un relèvement de la température d'évaporation et éventuellement de dégivrer l'évaporateur à air sans arrêter la production de chaleur. L'énergie de dégivrage est apportée par un thermosiphon diphasique formé entre les deux évaporateurs à des températures différentes. La présence d'un sous-refroidisseur impose le contrôle de la haute pression pour assurer une condensation totale du réfrigérant dans le condenseur utile. Le système de contrôle de pression est constitué d'une bouteille contenant du réfrigérant à l'équilibre liquide / vapeur connectée en partie basse à la ligne liquide et en partie haute au refoulement du compresseur et à un point en basse pression du circuit. Une injection de gaz provenant du refoulement du compresseur entraîne une augmentation de la haute pression. Une chasse vers la basse pression provoque une diminution de la haute pression du système. Une étude expérimentale a été menée sur une machine prototype de TFP au R407C pour des conditions variables de fonctionnement en températures d'air et d'eau et pour les différents modes possibles (chauffage, rafraîchissement et production simultanée). Les performances obtenues expérimentalement sont en accord avec celles annoncées par le logiciel de sélection développé par le constructeur du compresseur. L'étude expérimentale a également permis d'observer le dégivrage par thermosiphon, de vérifier le bon fonctionnement du système de gestion de la pression de condensation et des séquences alternées en période hivernale (1 : mode chauffage avec stockage de chaleur sur la boucle d'eau froide par sous-refroidissement. 2 : mode équilibré utilisant une évaporation par l'énergie stockée sur la boucle d'eau froide, plus performant, avec dégivrage éventuel). Le fonctionnement de la TFP a été modélisé avec deux réfrigérants : le HFC R407C et le CO2. Dans le contexte actuel animé par d'éventuelles décisions politiques concernant l'impact des gaz à effet de serre sur le réchauffement climatique, le dioxyde de carbone est un fluide intéressant d'abord pour son faible impact environnemental (ODP nul et GWP100ans = 1) et pour les caractéristiques particulières du cycle thermodynamique utilisé (cycle transcritique). En effet, une grande quantité d'énergie est récupérable par sous-refroidissement du fluide frigorigène et de l'ECS à haute température peut être produite de manière performante. Dans des simulations annuelles, les TFP au R407C et au CO2 sont comparées à des pompes à chaleur réversibles sur les critères de performance, d'économie d'énergie et d'impact environnemental. Le concept de cette TFP offre clairement une amélioration des performances par rapport à une pompe à chaleur réversible classique et l'utilisation du dioxyde de carbone présente de bonnes perspectives de développement.