• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • Tagged with
  • 8
  • 8
  • 8
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação do pH de oxidação do processo fenton na remoção de microcistina-LR de água de abastecimento

Silva, Aluízio Gonçalves da 24 November 2015 (has links)
Submitted by Jean Medeiros (jeanletras@uepb.edu.br) on 2016-04-27T14:30:56Z No. of bitstreams: 1 PDF - Aluízio Gonçalves da Silva.pdf: 2861910 bytes, checksum: fec467664bbab2d62bb600299f8e0d10 (MD5) / Made available in DSpace on 2016-04-27T14:30:56Z (GMT). No. of bitstreams: 1 PDF - Aluízio Gonçalves da Silva.pdf: 2861910 bytes, checksum: fec467664bbab2d62bb600299f8e0d10 (MD5) Previous issue date: 2015-11-24 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Algal blooms and toxic cyanobacteria in fountains intended for human supply has been reported in many countries in recent decades due to impacts and human actions in the most diverse ecosystems on the planet. The presence of lineages of cyanobacteria producing cyanotoxins has negative effects on water bodies in particular in the intendend to the public supply due to the harmful effect of these substances on human health and animals. In general, cyanotoxins are not removed by conventional purifying water technologies. This study aimed to evaluate the efficiency of advanced oxidation process with the Fenton reagent in the oxidation of microcystin-LR water for public supply using conventional treatment steps coagulation, flocculation and sedimentation. The study water was prepared by adding the lysed cell cultivation Microcystis aeruginosa dechlorinated with potable water. Oxidation steps were performed, coagulation, flocculation and sedimentation JarTest programmed with rapid mixing -1 time of 10 s, rapid mixing gradient of 1000 s , flocculation time 20 min, flocculation gradient -1 -1 30 s and sedimentation velocity 1,4 cm.min . Different pH ranges were tested (2,0, 4,5 and + 7,0) and different concentrations of the Fenton reagent in the proportion of 1/3 H2O/Fe . The obtained results showed the oxidation of microcystin-LR in the treatments with pH 2,0; 4,5; and 7,0. By scanning the ions in the mass spectrometer it was possible to identify the peaks of mass/charge (m/z) fragments of enabling confirmation of oxidation by the presence of oxidation by products. Furthermore, after sedimentation the Fenton reagent enables significant removal being treatment T2 in time of 15 minutes the best for include percentage removal of turbidity 0,07 uT, true color 2,61 uH, COD 7,7 mg.L and MC-LR 0,07 μg.L. / Florações de algas e cianobactérias tóxicas em mananciais destinados ao abastecimento humano tem sido relatado em vários países nas últimas décadas devido aos impactos e ações do homem nos mais diversos ecossistemas do planeta. A presença de linhagens de cianobactérias produtoras de cianotoxinas tem efeitos negativo nos corpos hídricos em particular nos destinados ao abastecimento público devido ao efeito nocivo dessas substâncias à saúde humana e de animais. Em geral as cianotoxinas não são removidas pelas tecnologias convencionais de potabilização de água. O presente trabalho buscou avaliar a eficiência do processo de oxidação avançada com o reagente Fenton na oxidação da microcistina-LR de água destinada ao abastecimento público utilizando as etapas de tratamento convencional de coagulação, floculação e sedimentação. A água de estudo foi preparada com adição de cultivo de células lisadas de Microcystis aeruginosa com água potável desclorada. Foram realizadas as etapas de oxidação, coagulação, floculação e sedimentação em JarTest programado com tempo de -1 mistura rápida de 10 s, gradiente de mistura rápida 1000 s , tempo de floculação 20 min, -1 -1 gradiente de floculação 30 s e velocidade de sedimentação de 1,4 cm.min . Foram testados diferentes faixas de pH (2,0, 4,5, e 7,0) e diferentes concentrações do reagente Fenton na 2+ proporção de 1/3 de H2O/Fe . Os resultados obtidos mostraram a oxidação da microcistina-LR nos tratamentos com pH 2,0; 4,5; e 7,0. Através da varredura dos íons no espetrômetro de massas foi possível identificar os picos de massa/carga (m/z) dos fragmentos possibilitando a confirmação da oxidação através da presença dos subprodutos da oxidação. Além disso, após a sedimentação o reagente Fenton possibilitou a remoção significativa sendo tratamento T2 no tempo de 15 minutos o melhor por abrangir percentuais de remoção de turbidez 0,07 uT, cor verdadeira 2,61 uH, COD 7,7 mg.L e MC-LR 0,07 µg.L.
2

Integração de processos físico-químicos e oxidativos avançados no tratamento de efluentes da indústria de laticínios / Integration of physicochemical and advanced oxidation process in treatment of dairy industry wastewater

Mendes, Paulo Ricardo Amador 01 April 2014 (has links)
Por meio das mudanças de paradigmas relacionados à gestão ambiental e elevação dos custos de lançamento de efluente, captação e tratamento de água, as indústrias passam por processos de inovação que resultam em melhor utilização dos recursos e maior diminuição dos custos. Além disso, as empresas estão sujeitas a maiores exigências quanto à legislação ambiental vigente impulsionando-as a implantar sistemas de reúso de efluentes. Apesar de representar uma importante atividade econômica, a indústria de laticínios é responsável pela geração de efluentes líquidos com alto potencial poluidor. O presente trabalho teve como objetivo a redução de contaminantes e melhoria da biodegradabilidade de efluentes de laticínios utilizando tratamentos combinados, em destaque, coagulação/floculação, processos com membranas e oxidação/redução química fotocatalítica. Os efluentes foram provenientes de uma indústria da região, oriundos da etapa de nanofiltração do soro ultrafiltrado. Eles foram divididos em duas correntes, denominadas de concentrado de nanofiltração (corrente 1) e permeado de nanofiltração (corrente 2). Para o tratamento da corrente 1 foi proposto inicialmente coagulação/floculação utilizando diferentes agentes coagulantes naturais (quitosana, derivado de tanino e extrato de moringa), seguido do uso de processos com membranas do tipo microfiltração (0,40 ?m em polieterimida) e ultrafiltração (50 kDa em polietersulfona). Para a corrente 2 foi proposto a utilização de Processos Oxidativos e Redutivos Avançados. Em todas as etapas foi utilizada a Metodologia da Superfície de Resposta para identificação das condições otimizadas. Para o tratamento de coagulação/floculação da corrente 1 foram avaliadas as influências do pH, dos coagulantes naturais e da agitação sobre as variáveis resposta reduções de carbono orgânico total (COT), demanda química de oxigênio (DQO) e turbidez. Na condição indicada como ótima foram alcançadas reduções de 18,3% de COT, 12,7% de DQO e 19,6% de turbidez. A partir da condição otimizada a corrente 1 foi submetida aos processos com membranas, sendo selecionada a microfiltração como melhor tratamento. O uso dessas membranas possibilitou reduções de 1,25% em COT, 5,21% em DQO e 87,4% em turbidez. A combinação destas tecnologias possibilitou a eliminação de 20,1%, 18,0%, 89,8% em COT, DQO e turbidez, respectivamente. Para o tratamento da corrente 2 foram utilizados diferentes tipos de processos oxidativos avançados sendo eles, foto-Fenton (íons ferrosos) e foto-Fenton avançado (uso de ferro metálico). Nestes casos foram avaliadas a influência das concentrações de peróxido de hidrogênio e íon ferroso e ferro metálico considerando como variáveis resposta reduções de COT e DQO. Os resultados otimizados obtidos para o POA foto-Fenton permitiram reduções de 89,9% em COT e 50,8% em DQO, enquanto os resultados otimizados para POA foto-Fenton avançado foram reduções de 74,9% de COT e 41,0% de DQO. / Through the paradigm changes related to environmental management and rising costs of effluent discharge, water abstraction and treatment, industries undergo innovation processes that result in better use of resources and greater reduction in costs. Moreover, companies are submitted to greater requirements regarding environmental regulations driving them to deploy reuse of wastewater systems. Despite representing an important economic activity, the dairy industry is responsible for producing wastewater with high pollution potential. The present work was carried out in order to reduce contaminants and improve the biodegradability of dairy effluent by using an hybrid wastewater treatment based on coagulation/flocculation, membrane process and photocatalytic chemical oxidation/reduction. The effluents came from a regional industry and originating from the nanofiltration step of an ultrafiltrate whey. They were divided into two streams, called nanofiltration concentrate (stream 1) and nanofiltration permeate (stream 2). For the treatment of stream 1 was initially proposed coagulation/flocculation using different natural coagulant agents (chitosan, derivative tannin and moringa extract), followed by membrane processes type of microfiltration (0.40 ?m in polyetherimide) and ultrafiltration (50 kDa in polyethersulfone). For the stream 2 Advanced Oxidation and Reductive Processes were performed. In all steps of the work Response Surface Methodology was used to identify the optimum conditions. For the coagulation/flocculation treatment, the influence of the pH, natural coagulants and agitation were evaluated on the response variables total organic carbon (TOC), chemical oxygen demand (COD) and turbidity reductions. The optimized results reduced of 18.3% TOC, 12.7% COD and 19.6% turbidity. From the indicated condition stream 1 was submitted to membrane processes, being selected the microfiltration as the best treatment. The use of theses membranes provided 1.25% TOC, 5.21% COD and 87.4% turbidity reductions. The combination of these technologies has enabled the elimination of 20.1%, 18.0%, 89.8% in TOC, COD and turbidity, respectively. For the treatment of the stream 2 different types of Advanced Oxidation Processes were used being them, photo-Fenton (ferrous ions) and advanced photo-Fenton (metallic iron). In this cases the influence of the hydrogen peroxide, ferrous ion and metallic iron concentrations were evaluated, considering as response variables TOC and COD reductions. The optimized results for the photo-Fenton AOP allowed 89.9% TOC and 50.8% COD reductions, while the results optimized for advanced photo-Fenton AOP were 74.9% TOC and 41.0% COD reductions.
3

Estudo da aplicação de foto-fenton solar como tratamento de chorume proveniente do aterro sanitário de Cachoeira Paulista-SP / Study of the Application of Solar Photo Fenton Treatment as leachate from the Landfill Cachoeira Paulista-SP

Cavalcanti, Alessandro Sampaio 12 April 2013 (has links)
O chorume in natura utilizado foi proveniente do aterro sanitário da cidade de Cachoeira Paulista no interior do estado de São Paulo. Possui baixa razão de biodegradabilidade (DBO/DQO = 0,094) evidenciado principalmente através das análises de caracterização dos parâmetros COT (618,1 mg C/L), DQO (4345,88 mg O2/L) e DBO5 (409,7 mg O2/L) que estão acima do limite permitido pela legislação. Em função disso, os processos oxidativos avançados (POA´s) surgem como alternativa para o seu pré-tratamento. O foco principal desse trabalho foi utilizar a aplicação da fotocatálise homogênea, empregando concomitantemente a luz solar com o reagente Fenton (H2O2 + Fe2+) num reator aberto com volume constante da amostra (3L) em sistema semi-batelada para verificar a eficiência do processo na remoção da carga orgânica. O reator solar possui um suporte de madeira que está direcionado ao Equador com um ângulo de inclinação de 23º, com uma placa metálica sem pigmentação denominada branco, numa vazão constante (13 L / min) em períodos com maior intensidade de radiação UV e monitorados pelo radiômetro. Após o ajuste do chorume de acordo com a planilha experimental, o volume do reagente Ferro (0,82 mol) foi adicionado totalmente no início da reação e o peróxido de hidrogênio (30% m/v) durante 30 min do tempo total de 1 hora, através de uma bureta dosadora, de maneira controlada que o peróxido de hidrogênio fosse consumido integralmente na reação de degradação, aumentando assim sua eficiência. O chorume tratado foi bombeado até a parte superior da placa, percolando-a uniformemente enquanto recebia a radiação solar sobre a placa. O processo fotocatalítico foi otimizado por um planejamento fatorial (23) com duplicata e triplicata no ponto central contendo 19 experimentos com variáveis de entrada: pH (3, 3,5 e 4) , quantidade de [H2O2] ( 73,2 g , 85,4 g e 97,6 g ) e quantidade de [Fe2+ ] (4,0 g , 5,0 g e 6,0 g ). As variáveis respostas do processo utilizadas foram: eficiência de remoção de COT (Carbono Orgânico Total) e DQO (Demanda Química de Oxigênio). As maiores reduções percentuais de DQO e COT, respectivamente, 89,19% e 86,12%, além do aumento de sua biodegradabilidade para 0,55 com um custo de R$ 0,3558 / 3L. Desta forma, o processo fotocatalítico mostrou grande viabilidade técnica e econômica em relação à degradação da carga orgânica de chorume. / The leachate used was fresh from the landfill of the city of Cachoeira Paulista in the state of São Paulo. Has a low ratio of biodegradability (BOD / COD = 0.094) demonstrated mainly through the analysis parameters characterizing the TOC (618,1 mg C / l) COD (mg O2 4345,88 / L) and BOD5 (mg O2 409,7 / L) that are above the limit allowed by law. As a result, the advanced oxidation processes (AOP\'s) are an alternative to their pre-treatment. The main focus of this work was to use the application of photocatalysis homogeneous, employing concurrently sunlight with Fenton\'s reagent (H2O2 + Fe2+) in an open reactor with constant volume of sample (3L) in the semi-batch to verify the efficiency of the process in removal of organic matter. The solar reactor has a wooden support that is directed to the equator with a tilt angle of 23 º, with a metal plate without pigmentation called white, a constant flow rate (13 L / min) in periods with higher UV intensity and monitored by radiometer. After adjusting the leachate according to the experimental sheet, the volume of reagent iron (0,82 mol) was added entirely at the beginning of the reaction and hydrogen peroxide (30% w / v) for 30 min to 1 hour total time through a dosing burette so controlled that the hydrogen peroxide was consumed entirely in the degradation reaction, thus increasing its efficiency. The treated leachate was pumped to the top of the plate evenly percolating while receiving the solar radiation on the plate. The photocatalytic process was optimized by a factorial design (23) with duplicate and triplicate center point experiments containing 19 input variables: pH (3, 3,5 and 4), the amount of [H2O2] (73,2 g, 85,4 g 97,6 g) and the amount of [Fe 2+] (4,0 g, 5,0 g and 6,0 g). The response variables of the process were: removal efficiency of TOC (Total Organic Carbon) and COD (Chemical Oxygen Demand). The largest percentage reductions of COD and TOC, respectively, 89,19% and 86,12%, besides increasing its biodegradability to 0,55 at a cost of R $ 0,3558 / 3L. Thus, the photocatalytic process showed great technical and economic feasibility in relation to the degradation of the organic leachate.
4

Estudo da aplicação de foto-fenton solar como tratamento de chorume proveniente do aterro sanitário de Cachoeira Paulista-SP / Study of the Application of Solar Photo Fenton Treatment as leachate from the Landfill Cachoeira Paulista-SP

Alessandro Sampaio Cavalcanti 12 April 2013 (has links)
O chorume in natura utilizado foi proveniente do aterro sanitário da cidade de Cachoeira Paulista no interior do estado de São Paulo. Possui baixa razão de biodegradabilidade (DBO/DQO = 0,094) evidenciado principalmente através das análises de caracterização dos parâmetros COT (618,1 mg C/L), DQO (4345,88 mg O2/L) e DBO5 (409,7 mg O2/L) que estão acima do limite permitido pela legislação. Em função disso, os processos oxidativos avançados (POA´s) surgem como alternativa para o seu pré-tratamento. O foco principal desse trabalho foi utilizar a aplicação da fotocatálise homogênea, empregando concomitantemente a luz solar com o reagente Fenton (H2O2 + Fe2+) num reator aberto com volume constante da amostra (3L) em sistema semi-batelada para verificar a eficiência do processo na remoção da carga orgânica. O reator solar possui um suporte de madeira que está direcionado ao Equador com um ângulo de inclinação de 23º, com uma placa metálica sem pigmentação denominada branco, numa vazão constante (13 L / min) em períodos com maior intensidade de radiação UV e monitorados pelo radiômetro. Após o ajuste do chorume de acordo com a planilha experimental, o volume do reagente Ferro (0,82 mol) foi adicionado totalmente no início da reação e o peróxido de hidrogênio (30% m/v) durante 30 min do tempo total de 1 hora, através de uma bureta dosadora, de maneira controlada que o peróxido de hidrogênio fosse consumido integralmente na reação de degradação, aumentando assim sua eficiência. O chorume tratado foi bombeado até a parte superior da placa, percolando-a uniformemente enquanto recebia a radiação solar sobre a placa. O processo fotocatalítico foi otimizado por um planejamento fatorial (23) com duplicata e triplicata no ponto central contendo 19 experimentos com variáveis de entrada: pH (3, 3,5 e 4) , quantidade de [H2O2] ( 73,2 g , 85,4 g e 97,6 g ) e quantidade de [Fe2+ ] (4,0 g , 5,0 g e 6,0 g ). As variáveis respostas do processo utilizadas foram: eficiência de remoção de COT (Carbono Orgânico Total) e DQO (Demanda Química de Oxigênio). As maiores reduções percentuais de DQO e COT, respectivamente, 89,19% e 86,12%, além do aumento de sua biodegradabilidade para 0,55 com um custo de R$ 0,3558 / 3L. Desta forma, o processo fotocatalítico mostrou grande viabilidade técnica e econômica em relação à degradação da carga orgânica de chorume. / The leachate used was fresh from the landfill of the city of Cachoeira Paulista in the state of São Paulo. Has a low ratio of biodegradability (BOD / COD = 0.094) demonstrated mainly through the analysis parameters characterizing the TOC (618,1 mg C / l) COD (mg O2 4345,88 / L) and BOD5 (mg O2 409,7 / L) that are above the limit allowed by law. As a result, the advanced oxidation processes (AOP\'s) are an alternative to their pre-treatment. The main focus of this work was to use the application of photocatalysis homogeneous, employing concurrently sunlight with Fenton\'s reagent (H2O2 + Fe2+) in an open reactor with constant volume of sample (3L) in the semi-batch to verify the efficiency of the process in removal of organic matter. The solar reactor has a wooden support that is directed to the equator with a tilt angle of 23 º, with a metal plate without pigmentation called white, a constant flow rate (13 L / min) in periods with higher UV intensity and monitored by radiometer. After adjusting the leachate according to the experimental sheet, the volume of reagent iron (0,82 mol) was added entirely at the beginning of the reaction and hydrogen peroxide (30% w / v) for 30 min to 1 hour total time through a dosing burette so controlled that the hydrogen peroxide was consumed entirely in the degradation reaction, thus increasing its efficiency. The treated leachate was pumped to the top of the plate evenly percolating while receiving the solar radiation on the plate. The photocatalytic process was optimized by a factorial design (23) with duplicate and triplicate center point experiments containing 19 input variables: pH (3, 3,5 and 4), the amount of [H2O2] (73,2 g, 85,4 g 97,6 g) and the amount of [Fe 2+] (4,0 g, 5,0 g and 6,0 g). The response variables of the process were: removal efficiency of TOC (Total Organic Carbon) and COD (Chemical Oxygen Demand). The largest percentage reductions of COD and TOC, respectively, 89,19% and 86,12%, besides increasing its biodegradability to 0,55 at a cost of R $ 0,3558 / 3L. Thus, the photocatalytic process showed great technical and economic feasibility in relation to the degradation of the organic leachate.
5

Integração de processos físico-químicos e oxidativos avançados no tratamento de efluentes da indústria de laticínios / Integration of physicochemical and advanced oxidation process in treatment of dairy industry wastewater

Paulo Ricardo Amador Mendes 01 April 2014 (has links)
Por meio das mudanças de paradigmas relacionados à gestão ambiental e elevação dos custos de lançamento de efluente, captação e tratamento de água, as indústrias passam por processos de inovação que resultam em melhor utilização dos recursos e maior diminuição dos custos. Além disso, as empresas estão sujeitas a maiores exigências quanto à legislação ambiental vigente impulsionando-as a implantar sistemas de reúso de efluentes. Apesar de representar uma importante atividade econômica, a indústria de laticínios é responsável pela geração de efluentes líquidos com alto potencial poluidor. O presente trabalho teve como objetivo a redução de contaminantes e melhoria da biodegradabilidade de efluentes de laticínios utilizando tratamentos combinados, em destaque, coagulação/floculação, processos com membranas e oxidação/redução química fotocatalítica. Os efluentes foram provenientes de uma indústria da região, oriundos da etapa de nanofiltração do soro ultrafiltrado. Eles foram divididos em duas correntes, denominadas de concentrado de nanofiltração (corrente 1) e permeado de nanofiltração (corrente 2). Para o tratamento da corrente 1 foi proposto inicialmente coagulação/floculação utilizando diferentes agentes coagulantes naturais (quitosana, derivado de tanino e extrato de moringa), seguido do uso de processos com membranas do tipo microfiltração (0,40 ?m em polieterimida) e ultrafiltração (50 kDa em polietersulfona). Para a corrente 2 foi proposto a utilização de Processos Oxidativos e Redutivos Avançados. Em todas as etapas foi utilizada a Metodologia da Superfície de Resposta para identificação das condições otimizadas. Para o tratamento de coagulação/floculação da corrente 1 foram avaliadas as influências do pH, dos coagulantes naturais e da agitação sobre as variáveis resposta reduções de carbono orgânico total (COT), demanda química de oxigênio (DQO) e turbidez. Na condição indicada como ótima foram alcançadas reduções de 18,3% de COT, 12,7% de DQO e 19,6% de turbidez. A partir da condição otimizada a corrente 1 foi submetida aos processos com membranas, sendo selecionada a microfiltração como melhor tratamento. O uso dessas membranas possibilitou reduções de 1,25% em COT, 5,21% em DQO e 87,4% em turbidez. A combinação destas tecnologias possibilitou a eliminação de 20,1%, 18,0%, 89,8% em COT, DQO e turbidez, respectivamente. Para o tratamento da corrente 2 foram utilizados diferentes tipos de processos oxidativos avançados sendo eles, foto-Fenton (íons ferrosos) e foto-Fenton avançado (uso de ferro metálico). Nestes casos foram avaliadas a influência das concentrações de peróxido de hidrogênio e íon ferroso e ferro metálico considerando como variáveis resposta reduções de COT e DQO. Os resultados otimizados obtidos para o POA foto-Fenton permitiram reduções de 89,9% em COT e 50,8% em DQO, enquanto os resultados otimizados para POA foto-Fenton avançado foram reduções de 74,9% de COT e 41,0% de DQO. / Through the paradigm changes related to environmental management and rising costs of effluent discharge, water abstraction and treatment, industries undergo innovation processes that result in better use of resources and greater reduction in costs. Moreover, companies are submitted to greater requirements regarding environmental regulations driving them to deploy reuse of wastewater systems. Despite representing an important economic activity, the dairy industry is responsible for producing wastewater with high pollution potential. The present work was carried out in order to reduce contaminants and improve the biodegradability of dairy effluent by using an hybrid wastewater treatment based on coagulation/flocculation, membrane process and photocatalytic chemical oxidation/reduction. The effluents came from a regional industry and originating from the nanofiltration step of an ultrafiltrate whey. They were divided into two streams, called nanofiltration concentrate (stream 1) and nanofiltration permeate (stream 2). For the treatment of stream 1 was initially proposed coagulation/flocculation using different natural coagulant agents (chitosan, derivative tannin and moringa extract), followed by membrane processes type of microfiltration (0.40 ?m in polyetherimide) and ultrafiltration (50 kDa in polyethersulfone). For the stream 2 Advanced Oxidation and Reductive Processes were performed. In all steps of the work Response Surface Methodology was used to identify the optimum conditions. For the coagulation/flocculation treatment, the influence of the pH, natural coagulants and agitation were evaluated on the response variables total organic carbon (TOC), chemical oxygen demand (COD) and turbidity reductions. The optimized results reduced of 18.3% TOC, 12.7% COD and 19.6% turbidity. From the indicated condition stream 1 was submitted to membrane processes, being selected the microfiltration as the best treatment. The use of theses membranes provided 1.25% TOC, 5.21% COD and 87.4% turbidity reductions. The combination of these technologies has enabled the elimination of 20.1%, 18.0%, 89.8% in TOC, COD and turbidity, respectively. For the treatment of the stream 2 different types of Advanced Oxidation Processes were used being them, photo-Fenton (ferrous ions) and advanced photo-Fenton (metallic iron). In this cases the influence of the hydrogen peroxide, ferrous ion and metallic iron concentrations were evaluated, considering as response variables TOC and COD reductions. The optimized results for the photo-Fenton AOP allowed 89.9% TOC and 50.8% COD reductions, while the results optimized for advanced photo-Fenton AOP were 74.9% TOC and 41.0% COD reductions.
6

[en] REMOVAL OF MANGANESE FROM WATERS AND INDUSTRIAL EFFLUENTS WITH USE OF HYDROGEN PEROXIDE / [pt] REMOÇÃO DE MANGANÊS DE ÁGUAS E EFLUENTES INDUSTRIAIS COM UTILIZAÇÃO DO PERÓXIDO DE HIDROGÊNIO

JULIANA SANTOS DOS SANTOS 07 April 2005 (has links)
[pt] Para remover metais de águas e efluentes aquosos, geralmente são empregados métodos tradicionais, os quais envolvem a neutralização, com posterior hidrólise e precipitação de hidróxidos, utilizando uma base.O manganês deve ser removido de águas e efluentes aquosos, até que sua concentração atinja um máximo exigido pela legislação brasileira, que é de 0,1mg/L para águas e 1mg/L para efluentes aquosos. O trabalho desenvolvido aqui investigou a remoção de manganês (II) utilizando os oxidantes: oxigênio, reagente Fenton e peróxido de hidrogênio, para procurar dentre estes um processo que fosse mais eficiente do que o de simples precipitação do hidróxido. São discutidos os resultados de ensaios realizados com a utilização de soluções sintéticas de manganês (II), cujo objetivo foi desenvolver um caminho que favorecesse a remoção deste metal, para que a concentração do mesmo tanto em águas quanto em efluentes aquosos esteja de acordo com os padrões exigidos pela legislação brasileira (resolução CONAMA 20/ 1986).Os ensaios foram realizados em pH de 7 a 10, a temperatura ambiente e em torno de 80ºC e com um tempo de reação de 5,15 e 30 minutos. Foi utilizado peróxido de hidrogênio em dosagem estequiométrica com excesso de 100% e 200%, para a reação: Mn2+ (aq) + H2O2 (aq) -> MnO2(s) + 2 H+ (aq) Dentre os testes realizados, ambos o peróxido de hidrogênio e o reagente Fenton mostraram-se bastante eficientes na remoção de manganês, permitindo atingir concentrações finais desse metal inferiores a 0,3 mg/L, a temperatura ambiente em valores de pH inferiores aos necessários para a precipitação sem oxidante, com O2. / [en] I order to remove metals from waters and aqueous effluents generally are employed traditional methods which involve neutralization, hydrolysis and precipitation of hydroxides using a base. Manganese must be removed from waters and aqueous effluents down to a concentration limited by Brazilian law which is of 0.1 mg/L for waters and 1.0 mg/L for aqueous effluents. The work carried out herein investigated the removal of manganese (II) using the following oxidants: oxygen, hydrogen peroxide, and Fenton reagent, with the aim to identify a process that could be more efficient than the simpler hydroxide precipitation. Results are discussed of experiments made with synthetic solutions of 1000 mg/L manganese (II) with the objective of developing a route that could favour the removal of that metal to the levels established by Brazilian environmental law (resolution CONAMA 20 / 1986).The experiments were conducted in pH 7 to 10, at temperature ambient and 80 oC, with reaction times of 5, 15 and 30 minutes. Hydrogen peroxide was used in excess levels of 100 and 200% for the reaction: Mn2+ (aq) + H2O2 (aq) -> MnO2 (s) + 2 H+ (aq) Amongst the conducted experiments, both hydrogen peroxide and the Fenton reagent were shown to be most effective, allowing final concentrations of manganese less than 0.3 mg/L, at ambient temperature, in pH values lower than those required for precipitation without oxidation or with O2 (air).
7

Avaliação do tratamento de efluente farmacêutico endoparasiticida por processos Fenton e Foto-Fenton / Evaluation of the treatment of endoparasiticide pharmaceutical effluent by Fenton and photo-Fenton processes

Gracielle Mayra Rodrigues Carvalho 04 November 2013 (has links)
A ocorrência de fármacos no meio ambiente tem se tornado um assunto de interesse nos últimos anos. A preocupação com a presença de produtos farmacêuticos decorre de sua persistência química, resistência microbiana, e efeitos sinérgicos, que levam às implicações toxicológicas. O objetivo deste trabalho foi avaliar o tratamento do efluente farmacêutico endoparasiticida. Para isso, os processos Fenton e Foto-Fenton foram usados para se obter a redução da carga orgânica do efluente em questão. Para a caracterização analítica do efluente farmacêutico in natura e tratado foram empregados métodos estabelecidos e otimizados, tais como DQO, COT, DBO5, Ferro, Sólidos (ST, STF, STV), fenol e análise de elementos via absorção atômica. Por meio de dois arranjos ortogonais - Taguchi L9 e Taguchi L16 - os parâmetros de melhor eficiência para o tratamento por Fenton e Foto-Fenton foram determinados. A matriz L9 foi utilizada para estudo exploratório dos fatores mais importantes na redução percentual da DQO. Este estudo mostrou que a condição experimental na qual se observou a maior porcentagem de redução de DQO (da ordem de 86,2 %) no efluente farmacêutico foi o experimento com reagente Fenton igual a 31,7g H2O2 e 2,2 g Fe2+, sem radiação ultravioleta, pH igual a 3,0 e temperatura de 30 °C. Já com a matriz L16 foram determinados os melhores experimentos, tendo como fatores resposta o percentual de redução do COT e percentual de degradação dos princípios ativos Fenbendazol e Triclabendazol. Portanto, a melhor configuração dos fatores foi Temperatura de 20°C, massa de H2O2 igual a 30 g, massa de Fe2+ igual a 2,5 g, pH igual a 3,0 e potência de radiação ultravioleta de 28 W, ou seja, a configuração que apresentou as maiores porcentagens de redução do COT (da ordem de 73,6%), degradação do Fenbendazol (da ordem de 77,8 %) e degradação do Triclabendazol (da ordem de 91,5 %). / The occurence of the drugs in the environment has become a subject of interest in the latest years. The concern with the presence of pharmaceutical products comes from its chemical persistence, microbial resistence and synergistic effects which lead to toxicological implications. The objective of this work was to evaluate of the treatment of endoparasiticide pharmaceutical effluent. For that, the photo-Fenton and Fenton were used for achieving the reduction of the organic load of the effluent in question. For the analytical characterization of pharmaceutical effluent in natura and treated were employed methods established and optimized such as DQO, COT, TOC, DBO5, Iron, Solid ( ST, STV, STF), phenol and element analysis via atomic absorption. By means of two orthogonal arrangements - Taguchi L9 and L16 - parameters of better efficiency in the treatment by Photo-Fenton and Fenton were determined. The L9 matrix was used for exploratory study of the most important factors in reducing the percentage of DQO. This study showed that the experimental condition, in which it was observed the highest percentage reduction of DQO (approximately 86.2%) in the pharmacist effluent, was the experiment with Fenton\'s reagent equal to 31,7g H2O2 e 2,2 g Fe2+, without ultraviolet radiation, pH equal to 3.0 and a temperature of 30 ° C. With the L16 matrix were determined as the best experiment with response factors the percentage reduction of COT and percentage of degradation of the active Fenbendazole and Triclabendazole. Therefore, the best configuration of the factors was 20 º C, H2O2 mass equal to 30g, Fe2 + mass of 2.5 g, and pH equal to 3.0 and power of 28W ultraviolet radiation, in other words the configuration that had the greatest percentage reduction of COT ( the order of 73.6%), Fenbendazole degradation (the order of 77.8%) and degradation Triclabendazole (the order of 91.5%).
8

Avaliação do tratamento de efluente farmacêutico endoparasiticida por processos Fenton e Foto-Fenton / Evaluation of the treatment of endoparasiticide pharmaceutical effluent by Fenton and photo-Fenton processes

Carvalho, Gracielle Mayra Rodrigues 04 November 2013 (has links)
A ocorrência de fármacos no meio ambiente tem se tornado um assunto de interesse nos últimos anos. A preocupação com a presença de produtos farmacêuticos decorre de sua persistência química, resistência microbiana, e efeitos sinérgicos, que levam às implicações toxicológicas. O objetivo deste trabalho foi avaliar o tratamento do efluente farmacêutico endoparasiticida. Para isso, os processos Fenton e Foto-Fenton foram usados para se obter a redução da carga orgânica do efluente em questão. Para a caracterização analítica do efluente farmacêutico in natura e tratado foram empregados métodos estabelecidos e otimizados, tais como DQO, COT, DBO5, Ferro, Sólidos (ST, STF, STV), fenol e análise de elementos via absorção atômica. Por meio de dois arranjos ortogonais - Taguchi L9 e Taguchi L16 - os parâmetros de melhor eficiência para o tratamento por Fenton e Foto-Fenton foram determinados. A matriz L9 foi utilizada para estudo exploratório dos fatores mais importantes na redução percentual da DQO. Este estudo mostrou que a condição experimental na qual se observou a maior porcentagem de redução de DQO (da ordem de 86,2 %) no efluente farmacêutico foi o experimento com reagente Fenton igual a 31,7g H2O2 e 2,2 g Fe2+, sem radiação ultravioleta, pH igual a 3,0 e temperatura de 30 °C. Já com a matriz L16 foram determinados os melhores experimentos, tendo como fatores resposta o percentual de redução do COT e percentual de degradação dos princípios ativos Fenbendazol e Triclabendazol. Portanto, a melhor configuração dos fatores foi Temperatura de 20°C, massa de H2O2 igual a 30 g, massa de Fe2+ igual a 2,5 g, pH igual a 3,0 e potência de radiação ultravioleta de 28 W, ou seja, a configuração que apresentou as maiores porcentagens de redução do COT (da ordem de 73,6%), degradação do Fenbendazol (da ordem de 77,8 %) e degradação do Triclabendazol (da ordem de 91,5 %). / The occurence of the drugs in the environment has become a subject of interest in the latest years. The concern with the presence of pharmaceutical products comes from its chemical persistence, microbial resistence and synergistic effects which lead to toxicological implications. The objective of this work was to evaluate of the treatment of endoparasiticide pharmaceutical effluent. For that, the photo-Fenton and Fenton were used for achieving the reduction of the organic load of the effluent in question. For the analytical characterization of pharmaceutical effluent in natura and treated were employed methods established and optimized such as DQO, COT, TOC, DBO5, Iron, Solid ( ST, STV, STF), phenol and element analysis via atomic absorption. By means of two orthogonal arrangements - Taguchi L9 and L16 - parameters of better efficiency in the treatment by Photo-Fenton and Fenton were determined. The L9 matrix was used for exploratory study of the most important factors in reducing the percentage of DQO. This study showed that the experimental condition, in which it was observed the highest percentage reduction of DQO (approximately 86.2%) in the pharmacist effluent, was the experiment with Fenton\'s reagent equal to 31,7g H2O2 e 2,2 g Fe2+, without ultraviolet radiation, pH equal to 3.0 and a temperature of 30 ° C. With the L16 matrix were determined as the best experiment with response factors the percentage reduction of COT and percentage of degradation of the active Fenbendazole and Triclabendazole. Therefore, the best configuration of the factors was 20 º C, H2O2 mass equal to 30g, Fe2 + mass of 2.5 g, and pH equal to 3.0 and power of 28W ultraviolet radiation, in other words the configuration that had the greatest percentage reduction of COT ( the order of 73.6%), Fenbendazole degradation (the order of 77.8%) and degradation Triclabendazole (the order of 91.5%).

Page generated in 0.1362 seconds