• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 74
  • 2
  • Tagged with
  • 76
  • 76
  • 52
  • 42
  • 35
  • 32
  • 26
  • 20
  • 19
  • 17
  • 14
  • 13
  • 12
  • 12
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Characterization of sludge generated at wastewater treatment plants health of the metropolitan region of Fortaleza aiming its use in agriculture / CaracterizaÃÃo do lodo gerado em estaÃÃes de tratamento de esgoto sanitÃrio da regiÃo metropolitana de Fortaleza visando sua utilizaÃÃo na agricultura

Keyve Mayane Bezerra 27 August 2014 (has links)
CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / A elevada produÃÃo de lodo nos grandes centros urbanos, aliada à necessidade de destinaÃÃo final adequada, tem gerado sÃrios problemas ambientais no paÃs. A maior parte do lodo produzida no mundo à destinada à incineraÃÃo, disposiÃÃo em aterros e uso agrÃcola. Dentre as alternativas de reaproveitamento, uma tÃcnica viÃvel à a utilizaÃÃo como adubo orgÃnico, devido aos nutrientes contidos, tornando-o um insumo com elevado valor econÃmico. O objetivo desse trabalho foi caracterizar o lodo proveniente de estaÃÃes de tratamento de esgotos sanitÃrios situadas na RegiÃo Metropolitana de Fortaleza, visando à reutilizaÃÃo na agricultura e possibilitando rotas alternativas para seu destino final. Foram realizadas coletas mensais de lodo no perÃodo de agosto a novembro de 2013. ApÃs a coleta, foi realizada a anÃlise dos parÃmetros: temperatura, pH, alcalinidade total, condutividade elÃtrica, Alcalinidade de Ãcidos VolÃteis (AAV), Ãcidos Graxos VolÃteis (AGV), peso especÃfico, teor de umidade, sÃrie de sÃlidos e nitrogÃnio, fÃsforo total, Demanda QuÃmica de OxigÃnio (DQO), alÃm de Coliforme total e Escherichia Coli e substÃncias inorgÃnicas (metais pesados e alguns nutrientes). Os resultados obtidos indicam que os lodos contÃm nutrientes, como nitrogÃnio e fÃsforo, necessÃrios ao crescimento das plantas, podendo ser utilizados como forma de reciclagem na agricultura, proporcionando um destino ambientalmente favorÃvel, desde que passe por um tratamento adequado para a remoÃÃo ou reduÃÃo dos patÃgenos antes de sua aplicaÃÃo. Todos os lodos apresentaram-se estÃveis para fins de utilizaÃÃo agrÃcola, visto que no estudo foi encontrada uma relaÃÃo SV/ST menor que 0,70. De acordo com a concentraÃÃo de metais pesados, eles poderiam ser reutilizados na agricultura, pois apresentaram baixos valores em relaÃÃo aos limites estabelecidos na legislaÃÃo braseileira, porÃm hà restriÃÃo, apenas, ao lodo sÃptico, devido à faixa de concentraÃÃo do zinco exceder o limite mÃximo de concentraÃÃo permitido pela ResoluÃÃo n CONAMA 375/2006. / The high production of sludge in large urban centers, coupled with the need for proper disposal, has generated serious environmental problems in the country. Most of sludge produced worldwide is intended for incineration, landfilling and agricultural use. Among the alternatives to reuse a viable technique is to use as organic fertilizer because the nutrients contained, making it an input with high economic value. The aim of this study was to characterize the sludge from the wastewater treatment plants located in the Metropolitan Region of Fortaleza, in order to reuse in agriculture and providing alternative routes to their final destination. Monthly samples of sludge were carried out in the period August to November 2013 After collection, the analysis of the parameters was performed: temperature, pH, total alkalinity, conductivity, alkalinity of Volatile Acids (AAV), Volatile Fatty Acids (VFA) , specific weight, moisture content, solids and nitrogen, total phosphorus, chemical oxygen demand (COD), and Total Coliform and Escherichia Coli and inorganic substances (heavy metals and some nutrients). The results indicate that the sludge contains nutrients such as nitrogen and phosphorus necessary for the growth of plants and may be used as a form of recycling in agriculture, providing an environmentally friendly target, provided that pass through a suitable treatment for the removal or reduction of pathogens before its application. All slurries exhibited stable for agricultural use, whereas in one study SV / ST ratio less than 0.70 was found. According to the concentration of heavy metals, they could be reused in agriculture, as had lower values ​​compared with the limits established in legislation braseileira, but no restriction, just, septic sludge, due to the concentration range of zinc exceeds the maximum limit concentration permitted by CONAMA Resolution No. 375/2006.
42

Desempenho de reator anaeróbio híbrido (leito fixo e manta de lodo) tratando esgoto sanitário em escala piloto / Performance of anaerobic hybrid reactor (fixed bed and sludge blanket) for sewage treatment in pilot scale

Thiago Lopes da Silva Araujo 09 June 2014 (has links)
O presente trabalho estudou o aumento de capacidade de tratamento de um reator UASB (Upflow Anaerobic Sludge Blanket) por meio da adição de material suporte para adesão celular (Biobob®), avaliando-se as eficiências de remoção de matéria orgânica (expressa como DQO demanda química de oxigênio) e sólidos em suspensão (expressos como SST sólidos em suspensão totais). O reator híbrido, no qual a biomassa está presente em suspensão e imobilizada no material suporte, foi submetido a baixos tempos de detenção hidráulica (TDH) e altas velocidades ascensionais (vs). A operação do reator anaeróbio, de volume útil igual a 12,5 m³, foi conduzida em duas etapas. Na primeira o sistema foi operado como um reator de manta de lodo e escoamento ascendente (UASB), com TDH de 8,8 h e velocidade ascensional de 0,63 m.h-1. Na segunda etapa, introduziu-se 5,0 m³ de material suporte Biobob® no leito reacional do reator, transformando-o em reator anaeróbio híbrido (HAnR). Nessa condição, variou-se a vazão de alimentação, tendo o TDH variado entre 7,4 h (vs de 0,66 m.h-1) a 3,9 h (vs de 1,25 m.h-1). Para ambas as etapas o sistema foi alimentado com esgoto sanitário à temperatura ambiente, após tratamento preliminar (gradeamento e caixa de areia). Para condições de operação similares, o reator anaeróbio híbrido (HAnR) apresentou melhor desempenho na remoção de DQO e SST que o reator UASB, acrescendo em até 18% e 30% a eficiência de remoção, respectivamente. Para a velocidade ascensional de 1,25±0,02 m.h-1 e TDH de 3,9±0,1 h, o HAnR apresentou concentrações médias no efluente tratado de 205±46 mg DQOt.L-1 e 73±30 mg SST.L-1 e eficiências de remoção de 55±9% DQOt e 63±14% SST. / The increase of the treatability capacity of a UASB (Upflow Anaerobic Sludge Blanket) reactor by introducing an innovative packing material (Biobob®) in its reaction zone was evaluated. The hybrid anaerobic reactor (HAnR) containing suspended and immobilized biomass was evaluated regarding its efficiency of removing organic matter (expressed as COD chemical oxygen demand) and suspended solids (expressed as TSS total suspended solids) under lower hydraulic detention time (HDT) and higher upflow velocities (v s). The anaerobic reactor operation, with 12.5 m³ of working volume, was conducted in two phases. In the first phase, the system was operated as a conventional UASB reactor with HRT of 8.8 h and vs of 0.63 m.h -1 . In the second phase, 5.0 m³ of packing material Biobob® was introduced inside the reaction bed, changing the reactor configuration from suspended growth to hybrid growth. In this condition, the hybrid anaerobic reactor (HAnR) was subjected to decreasing flowrates with HDT ranging from 7.4 h (vs of 0.66 m.h-1) to 3.9 h (vs of 1.25 m.h-1). For both phases, the feed was domestic wastewater (after screens and grit chambers) at ambient temperature. Under similar operation conditions, the HAnR performed better than the UASB reactor increasing at 18% and 30% the COD and TSS removal efficiencies, respectively. For vs of 1.25±0.02 m.h-1 and HDT of 3.9±1.0 h, the HAnR produced a very high quality effluent, with average COD and TSS concentration of 205±46 mg DQOt.L-1 and 73±30 mg SST.L-1 and removal efficiencies of 55±9% and 63±14% for CODt and SST, respectively.
43

Reator híbrido associando reator UASB e reator radial de leito fixo (RRLF), em escala piloto, no tratamento de esgoto sanitário / not available

Alexandre Colzi Lopes 10 June 2005 (has links)
Os sistemas combinados anaeróbio/aeróbio para tratamento de esgotos sanitários têm sido considerados alternativas viáveis do ponto de vista técnico-econômico em relação aos sistemas tradicionais. Este trabalho apresenta os resultados obtidos com uma nova configuração de reator, composto por uma unidade central - um reator anaeróbio de manta de lodo (UASB) modificado de 286 L, associado a um reator radial aerado de leito fixo (RRLF) de 215 L, disposto de maneira a circundar a zona de separação sólido/líquido/gás do reator UASB. A principal modificação no reator UASB foi, portanto, a incorporação, junto à sua parede externa, do RRLF. A alimentação do RRLF com o efluente do UASB dá-se através de aberturas laterais na parede do UASB, o que permitiu eliminar as calhas de coleta e sistemas de alimentação do segundo reator. Esse sistema foi alimentado com esgoto sanitário obtido da rede coletora de esgotos do campus da USP de São Carlos. Esperava-se obter remoção considerável de matéria orgânica solúvel e particulada, bem como a remoção parcial de nitrogênio. Foram obtidas eficiências médias de remoção de matéria orgânica (expressa como demanda química de oxigênio - DQO) e de sólidos suspensos voláteis (SSV), de 80% e 89%, respectivamente. Em condições de operação estável, os valores de DQO e SSV no efluente atingiram 110 mg/L e 16 mg/L, respectivamente. Observou-se, também, que o sistema apresentou grande estabilidade operacional, tendo a taxa de carregamento orgânico volumétrica atingido valores da ordem de 4,0 Kg DQO.m-3d-1. Nessas condições, o sistema atingiu eficiências de remoção de DQO e SSV da ordem de 90%. O sistema misto ensaiado mostrou ser uma configuração promissora, pois promoveu a remoção eficiente de matéria orgânica e de sólidos suspensos. Considera-se, no entanto, a necessidade de se introduzirem modificações no projeto RRLF que permitam o estabelecimento dos processos de nitrificação e desnitrificação nesse reator, uma vez que foi obtida baixa eficiência de nitrificação e, conseqüentemente, a remoção de nitrogênio foi prejudicada. / Integrated anaerobic/aerobic systems have been considered feasible alternatives concerning technical and economic aspects for treating domestic wastewaters. This paper presents the results obtained from the operation of this new reactor configuration, made up of a central unit - an upflow anaerobic sludge blanket reactor (UASB), with a working volume of 286 L, associated to a radial-flow aerobic immobilized-biomass (RAIB), with a working volume of 215 L. The RAIB reactor circles the solid/liquid/gas separation zone. The main modification in the UASB reactor concerns this association with the RAIB. The UASB effluent was distributed through openings along its side walls to the RAIB, allowing the elimination of collecting channels and feeding devices from the latter reactor. The objective of this work was to promote organic matter (raw and soluble) and nitrogen removal from domestic sewage. Organic matter (as COD) and volatile suspended solids removal achieved efficiencies of 80% and 89%, respectively. Under stable operational conditions, the system effluent presented COD and volatile suspended solids values of 110 mg/L and 16 mg/L, respectively. Efficiencies of 90% for COD and volatile suspended solids removal were achieved with a organic loading rate of 4,0 Kg COD.m-3.d-1. This integrated system has shown to be a valid configuration, efficiently removing organic matter and suspended solids from the domestic wastewater. However, contrarily to expectations based on the previous studies with RAIB, nitrification was poor. Therefore, modifications to the RAIB design must be considered for the establishment of nitrogen removing processes.
44

Remoção de cistos Giardia spp. e oocistos de Cryptosporidium spp. em sistemas de tratamento combinado (anaeróbio/físico-químico) de água residuária / Removal Giardia spp. cysts and Cryptosporididum spp. oocysts in combined treatment systems (anaerobic/physical-chemical) of wastewater

Gabriela Laila de Oliveira 18 November 2016 (has links)
O presente estudo visou investigar e monitorar a remoção de cistos de Giardia spp. e oocistos de Cryptosporidium spp. em processos combinados (anaeróbio-físico-químico) de uma estação de tratamento de esgoto (ETE), composta por tratamento preliminar, reator UASB (escala piloto) seguido de coagulação, floculação e sedimentação (equipamento jarteste em escala de bancada) ou coagulação, floculação e flotação por ar dissolvido – FAD (equipamento flotateste em escala de bancada), e verificar a ocorrência desses protozoários no lodo do reator UASB e do processo de sedimentação. Verificou-se a qualidade das amostras a partir de variáveis físicas e químicas, e pela detecção de microrganismos indicadores – E.coli e coliformes totais. Os métodos de detecção de protozoários se basearem nas etapas de concentração (tripla centrifugação ou filtração em membrana seguida de tripla centrifugação); purificação por separação imunomagnética (IMS); detecção por reação de imunofluorescência direta (RID). As recuperações de cistos e oocistos variaram de 25,9 a 41,2% e de 5,8 a 22,2%, respectivamente. Foram detectadas significativas quantidades de cistos de Giardia spp. em 100% das amostras de esgoto analisadas, com concentrações médias no esgoto bruto de 4,27x103 cistos.L-1 na etapa 1 e 3 (TDH de 12 horas) e 3,18x103 cistos.L-1 na etapa 2 (TDH de 8 horas). No esgoto tratado após processo de sedimentação as concentrações médias foram 327,4 cistos.L-1 no tratamento utilizando coagulante cloreto férrico e 3,8 cistos.L-1 utilizando tanino, ambos na etapa 1, já na etapa 2 esses mesmos tratamentos apresentaram efluente com concentrações médias de 211,6 e 29,6 cistos.L-1, respectivamente. No efluente tratado após o processo de flotação as concentrações médias de cistos de Giardia spp. foram de 8,0 cistos.L-1 com coagulante cloreto férrico e 1,5 cistos.L-1 com PAC, na etapa 3, e de 7,0 cistos.L-1 com cloreto férrico e 5,3 cistos.L-1 com PAC na etapa 2. Os oocistos de Cryptosporidium spp. foram detectados com menor frequência nas amostras de esgoto, como concentrações médias de 18,7 oocistos.L-1 no esgoto bruto nas etapas 1 e 3 e de 23,0 oocistos.L-1 na etapa 2. As eficiências de remoção de cistos de Giardia spp. dos tratamentos combinados variaram de 1,1 log a 3,4 log. O lodo do reator UASB e o lodo da etapa de sedimentação apresentaram altas quantidades de (oo)cistos, evidenciando a tendência de remoção de (oo)cistos por processos físicos como a sedimentação. O processo de flotação foi mais eficiência que o processo de sedimentação na remoção de (oo)cistos, mas devido à pequena quantidade de lodo não foi possível quantificar os (oo)cistos no lodo flotado. / The aim of study was to investigate and monitor the removal of Giardia spp. cysts and Cryptosporididum spp. oocysts through different combined treatment (anaerobic/physicalchemical) of a sewage treatment plant (STP), consisted of preliminary treatment, UASB reactor (pilot scale) followed by sedimentation (jartest equipment in bench scale) or by dissolved air flotation (flotatest equipment in bench scale). Moreover, it was investigated the occurrence of protozoa in the sludge of the UASB reactor and sedimentation process. It was analyzed the quality of the samples through physical and chemical variables and detection of indicator microorganisms – E. coli and total coliforms. The detection methods of protozoa were based on steps of concentration (triple centrifugation or membrane filtration followed by triple centrifugation); purification by immunomagnetic separation (IMS); immunofluorescence assay (IFA). The recovery of cysts and oocysts ranged from 25,9 to 41,2% and from 5,8 to 22,2%, respectively. Significant quantities of Giardia spp. cysts were detected in 100% of the analyzed wastewater samples, with mean concentration of 4,27x103 cysts.L-1 in raw watewater in step 1 and 3 (THD 12 hours) and 3,18x103 cysts.L-1 in step (THD 8 hours). In treated wastewater after the sedimentation process the mean concentration were 327,4 cysts.L-1 with ferric chloride and 3,8 cysts.L-1 with tannin, both in step 1, and in step 2 the same treatments were with mean concentration of 211,6 and 29,6 cysts.L-1, respectively. In treated wastewater after flotation process the mean concentration were 8,0 cysts.L-1 with ferric chloride and 1,5 cysts.L-1 with PAC in step 3 and 7,0 cysts.L-1 with ferric chloride and 5,3 cysts.L-1 with PAC in step 2. The oocysts of Cryptosporidium spp. were detected less often in the wastewater samples, with mean concentration of 18,7 oocysts.L-1 in raw wastewater in steps 1 and 3 and of 23,0 oocysts.L-1 in step 2. The overall removal for Giardia spp. was on average of 1,1 to 3,4 log. The sludge from UASB reactor and sedimentation process presented high quantities of (oo)cysts, implying the tendency of these systems to remove (oo)cysts by its physical processes such as sedimentation. The flotation process was more eficiente than the sedimentation process in the (oo)cysts removal, but due to the small amount of sludge was not possible to quantify the (oo)cysts in the float sludge.
45

Coagulação, floculação e flotação do efluente de reatores anaeróbios, tratando esgoto sanitário, com aplicação de diferentes dosagens de coagulante em função da variação da turbidez do esgoto afluente ao longo do dia / Coagulation, flocculation and flotation of anaerobic reactor effluents, treating sewage with the employment of different amounts of coagulant, according to the variation in sewage turbidity throughout the day

Ariano, Gustavo Carneiro 11 September 2009 (has links)
Este trabalho avaliou a técnica de dosagem variável de coagulante em função da variação da turbidez do esgoto afluente a sistema de pós-tratamento por flotação do efluente de reatores UASB, localizado em Campinas, SP. Utilizou-se equipamento do tipo Flotateste para a flotação em escala de laboratório, sendo fixados os parâmetros: Tmr = 15 s; Gmr = 800 \'S POT.-1\'; Tfloc = 20 min; Gfloc = 90 \'S POT.-1\'; Psat = 5,00 Bar. Foram estudadas quatro velocidades de flotação (Vf), entre 8 à 20 cm/min. Na fase 1 da pesquisa estudou-se os coagulantes \'AL IND.2\'(\'SO IND.4\')\'IND.3\', PAC e \'FE\'Cl IND.3\', sendo determinadas as melhores dosagens para o horário das 12:00 horas. Posteriormente, na segunda fase, foram fixadas as melhores dosagens de cada coagulante e associada dosagens variadas de polímeros catiônico, aniônico e não iônico. Em seguida, na fase 3, foi realizada avaliação temporal, com ensaios realizados em seis diferentes horários do dia, estabelecendo uma razão entre a variação da turbidez afluente com a dosagem de coagulante. Finalmente, na quarta fase, foram aplicados quatro cenários de dosagens em doze horários diferentes ao longo de 24 horas. Para fase 1, verificou-se remoção de SST, DQO e fósforo para as dosagens de \'AL IND.2\'(\'SO IND.4\')\'IND.3\' (11,77mg \'AL IND.2\'O IND.3\'/L), 76,5%; 67,6% e 63,9%; PAC (8,45 mg \'AL IND.2\'O IND.3\'/L), 62,5%; 75,0% e 82,7%; e \'FE\'CL IND.3\' (24,38 mg\'FE\'/L), 60,0%; 55,9% e 90,3%, respectivamente, para Vf = 16 cm/min. Na fase 2, determinou-se como melhor polímero, para ambos coagulantes, o polímero catiônico (PC), sendo associado às melhores dosagens definidas na fase1. Desta maneira na fase 2 verificou-se remoção de SST, DQO e fósforo para as dosagens associadas de \'AL IND.2\'(\'SO IND.4\')\'IND.3\' + PC (11,77 mg\'AL IND.2\'O IND.3\'/L + 1,00 mg PC/L), 94,4%, 88,6% e 70,4%; PAC + PC (8,45 mg\'AL IND.2\'O IND.3\'/L + 1,00 mg PC/L), 94,7%, 62,3% e 88,8%; e \'FE\'CL IND.3\' + PC (24,38 mg\'FE\'/L + 1,00 mg PC/L), 77,3%, 61,6% e 91,6%, respectivamente. O cloreto férrico foi escolhido para ser utilizado nas fases seguintes devido a capacidade de precipitação de sulfeto o qual atingiu concentrações de até 15 mg/L no efluente anaeróbio. Em adição, foram fixadas as dosagens de polímero catiônico em 1,00 mg/L. Assim, para fase 3, a aplicação de dosagem variada entre 12,07 a 25,51 mg\'FE\'/L, para seis diferentes horários resultou em DQO < 50 mg/L e Fósforo < 0,50 mg/L para Vf = 16 cm/min. A aplicação de razão entre a dosagem de \'FE POT.+3\' e a turbidez afluente (RDmT) de 0,463 mg\'FE POT.+3\'/L.UNT (para turbidez < 50 UNT) e 0,244 mg\'FE POT.+3\'/L.UNT (para turbidez >50 UNT) na fase 4, garantiu para todas as velocidades de flotação estudadas turbidez < 15 UNT em 100% dos ensaios. Em adição, ao se realizar correlação entre a concentração de SST no efluente da FAD e a turbidez, chegou-se a conclusão de que este cenário atingiu remoção de lodo próxima a dosagem de \'FE\'CL IND.3\' máxima definidas na fase 3 (74 mg\'FE\'CL IND.3\'/L), com economia de 27,8% no consumo do coagulante. / This study evaluated the variable coagulant dosage technique according to the variation in turbidity of the influent sewage of the post-treatment flotation system of the UASB reactor effluents, located in Campinas, SP. Laboratory scale flotation equipment was used, with fixed parameters: Tmr = 15 s; Gmr = 800 \'S POT.-1\'; Tfloc = 20 min; Gfloc = 90 \'S POT.-1\'; Psat = 5,00 Bar. Four flotation velocities (Vf), between 8 a 20 cm/min, were studied. Phase 1 of the research studied the coagulants \'AL IND.2\'(\'SO IND.4\')\'IND.3\', PAC e \'FE\'CL IND.3\', being determined the best dosages for 12:00 pm. In phase 2 the best dosages of each coagulant were fixed and the associated cationic, anionic and nonionic polymer dosages were varied. In phase 3 experiments were taken at six different periods of the day, establishing a ratio between the variation in influent turbidity and coagulant dosage. In the fourth phase, four different dosage scenarios were applied at twelve different periods during a 24 hour day, to verify the best dosage scenario. In phase 1, the removal of TSS, COD and phosphorus was verified to the dosages of \'AL IND.2\'(\'SO IND.4\')\'IND.3\' (11,77 mg\'AL IND.2\'O IND.3\'/L), 76,5%; 67,6% and 63,9%; PAC (8,45 mg\'AL IND.2\'O IND.3\'/L), 62,5%; 75,0% and 82,7%; and \'FE\'CL IND.3\' (24,38 mg\'FE POT.+3\'/L), 60,0%; 55,9% e 90,3%, respectively, for Vf = 16 cm/min. In phase 2 the cationic polymer (PC) was determined to be the best polymer for both coagulants, when applied to the best dosages determined in phase 1. This way, in phase 2 the removal of TSS, COD and phosphorus was verified to the associated dosages of \'AL IND.2\'(\'SO IND.4\')\'IND.3\' + PC (11,77 mg\'AL IND.2\'O IND.3\'/L + 1,00 mg PC/L), 94,4%, 88,6% and 70,4%; PAC + PC (8,45 mg\'AL IND.2\'O IND.3\'/L + 1,00 mg PC/L), 94,7%, 62,3% and 88,8%; and \'FE\'CL IND.3\' + PC (24,38 mg\'FE POT.+3\'/L + 1,00 mg PC/L), 77,3%, 61,6% e 91,6%, respectively. Ferric chloride was chosen in the following phases due to its sulfide precipitation ability, reaching concentrations of up to 15 mg/L in the anaerobic effluent. In addition, the cationic polymer dosages were fixed to 1,00 mg/L. Thus, in phase 3, the dosage, varying between 12,07 to 25,51 mg\'FE POT.+3\'/L, applied to six different periods resulted, to Vf = 16 cm/min, in COD < 50 mg/L and phosphorus < 0,50 mg/L. The ratio between the dosage of \'FE POT.+3\' and the influent turbidity (RDmT) of 0,463 mg\'FE POT.+3\'/L.UNT (for turbidities < 50 NTU) and 0,244 mg\'FE POT.+3\'/L.UNT (for turbidities \'< OU =\' 50 NTU) when applied in phase 4, ensured, in 100% of the experiments, turbidity < 15 NTU for the studied flotation velocities. In addition, when correlating the concentration of TSS in FAD effluents with the turbidity, the conclusion was that this scenario reached a sludge removal close to that obtained by the maximum \'FE\'CL IND.3\' dosage defined in phase 3 (74 mg\'FE\'CL IND.3\'/L), with an economy of 27,8% in coagulant consumption.
46

Aplicação de reatores anaeróbios para remoção de sulfato de águas de drenagem ácida de minas

Rodriguez, Renata Piacentini 30 April 2010 (has links)
O presente trabalho teve, por objetivo principal, analisar a remoção de sulfato em águas de drenagem ácida de minas em dois tipos de reatores anaeróbios, um com crescimento granular (UASB) e outro com biomassa aderida (RAHLF). Estudos anteriores publicados na literatura apresentam resultados positivos quanto ao tratamento anaeróbio de drenagem ácida de minas, entretanto, na maioria deles, é aplicado um tratamento preliminar à água residuária antes do tratamento principal. Esse trabalho avaliou a operação de reatores anaeróbios sem prévio tratamento da drenagem ácida sob diferentes variáveis. Para o reator anaeróbio horizontal de leito fixo (RAHLF), foram analisadas as variáveis relação DQO/\'SO IND.4\'POT.2-\', correção do pH afluente, carga de sulfato aplicada e a recirculação da fase líquida. Os resultados mostraram que a redução da carga de sulfato aplicada foi o fator determinante para os bons resultados de remoção, encontrados ao longo da operação dos reatores (70% de remoção de sulfato e 75% de remoção de DQO). A relação DQO/\'SO IND.4\'POT.2-\' também foi importante e quando utilizada a relação estequiométrica de 0,67, a eficiência de remoção de sulfato atingiu níveis superiores a 70% com pequeno acúmulo de ácido acético no efluente. Para a operação do reator anaeróbio de manta de lodo (UASB), as variáveis analisadas foram o volume da manta de lodo, a relação DQO/\'SO IND.4\'POT.2-\', a carga de sulfato aplicada e a recirculação da fase líquida. Como para o RAHLF, a redução da carga de sulfato aplicada foi essencial para o melhor funcionamento do UASB. A relação DQO/\'SO IND.4\'POT.2-\' de 1,0 promoveu melhora na eficiência do reator, quando comparada à relação estequiométrica e a recirculação no reator só foi positiva quando realizada com água de abastecimento, tendo o reator entrado em colapso quando a recirculação foi realizada com o efluente tratado. / The main objective of this work was to evaluate the sulfate removal from acid mine drainage in two types of anaerobic reactors, one with a granular sludge (UASB) and another with immobilized biomass (HAIB reactor). Previous published studies have showed positive results for the anaerobic treatment of acid mine drainage, however, in most of them, it was applied a pre-treatment operation. This study evaluated the operation of anaerobic reactors without pre-treatment of the acid mine drainage under different parameters. The parameters COD/\'SO IND.4\'POT.2-\' ratio, correction of affluent pH, sulfate loading and recirculation of the liquid phase were tested for horizontal-flow anaerobic immobilized biomass (HAIB) reactor. The results showed that the decrease in the sulfate loading was a determining factor for the successful sulfate removal found throughout the operation of the reactors. The COD/\'SO IND.4\'POT.2-\' ratio was also important and the removal efficiency of sulfate reached levels above 70% with a small accumulation of acetic acid in the effluent when using stoichiometric ratio of 0.67. For the operation of the upflow anaerobic sludge blanket (UASB) reactor, the parameters were the volume of the sludge blanket, the COD/\'SO IND.4\'POT.2-\' ratio, the sulfate loading and the recirculation of the liquid phase. Similarly ti the HAIB reactor, reducing the sulfate load was essential for obtaining better results. The COD/\'SO IND.4\'POT.2-\' ratio of 1.0 showed a improved sulfate removal efficiency for the UASB reactor when compared to stoichiometric ratio at 0.67 ant the recirculation in this reactor was only positive when carried out with tap water. The UASB reactor collapsed when recirculation was carried out whit the treated effluent.
47

Resposta dinâmica dos reatores UASB (Upflow Anaerobic Sludge Blanket) submetidos a cargas senoidais / not available

Batista, Kátia Bakker 16 November 2000 (has links)
Esta pesquisa consistiu na verificação do comportamento do reator UASB de bancada (volume igual a 10,5 litros), quando submetido a variações senoidais de vazão afluente, comparando-se com a eficiência no seu funcionamento com vazão constante, através de análises de amostras de afluentes e efluentes. O reator UASB utilizado foi montado no Laboratório de Processos Biológicos da EESC-USP dentro de uma câmara com temperatura constante de 30 ± 3°C, e alimentado com esgoto sintético, com DQO de 500 mg/l, 750 mg/l e 1000 mg/l. O reator foi inoculado em abril de 1999, com 3,5 litros de lodo anaeróbio proveniente de um reator compartimentado, também situado na EESC-USP. Devido à dificuldade de atingir um valor esperado para a eficiência de remoção de Matéria orgânica, foi dada nova partida no reator, em julho de 1999, desta vez com lodo proveniente de outro UASB. Após a segunda partida, o reator operou com vazão constante e DQO afluente em torno de 500 mg/l até setembro de 1999, com média de remoção de DQO bruta de 75% no período, passando-se, então, à fase de variação senoidal de vazão de forma que o máximo e o mínimo fossem de ±30%, ±45% e ±60% da vazão média. Para este regime, obteve-se 80% de eficiência média de remoção de DQO bruta. Os valores de pH, alcalinidade e ácidos voláteis foram praticamente constantes durante a operação. Os perfis de remoção de DQO ao longo do dia mostraram uma pequena queda na eficiência do reator, aproximadamente 1,5 vezes o tempo de detenção hidráulica médio (8 horas), após os máximos de vazão para o regime de variação de vazão de ±30% e ±45% e 2,5 vezes o tempo de detenção hidráulica médio, para variação e ±60%. O mesmo experimento foi repetido para DQO afluente de 1000 mg/l e obteve-se, em média, eficiências de 65% de remoção de DQO. / This research consisted in the UASB reactor performance verification when it was submitted to sine-based variations of loading rate, in comparison to its normal operation. The UASB reactor used was set up at the Biological Process Laboratory of EESC-USP, inside a camera with temperature of 30°C ± 3°C. It was fed with synthetic sewage (COD = 500, 750 and 1000 mg/l). After start-up, the reactor was operated with constant loading rate (COD = 500 mg/l) until September 1999. The organic matter removal average in this period was 75%. Then, it was initiated the phase of sine-based variation loading rate (±30%, ±45% and ±60%). In this regime, it was obtained a medium gross COD removal efficiency of 80%. The pH values, alkalinity and volatile acids were practically constant during the operation. The COD removal profiles during the day showed a subtle fall in the reactor efficiency after 1.5 times the medium hydraulic detection time, for the loading rate variation of ±30% and ±45%. For ±60% variation, the answer time was approximately 2.5 times the medium hydraulic detection time. The efficiency of gross COD removal stay however over 78,53% until the experiment 9, witch showed that the reactor can stand the loading rate variations. The efficiency of filtered COD removal decreased on the second experiment, came back to the initial values and decreased again. The values of variation didn\'t surpass 6,6% for gross COD and 8,43% for filtered COD.
48

Biofiltro aerado submerso aplicado ao pós-tratamento de efluente de reator UASB, sob condições hidráulicas desfavoráveis: estudo em escala real / Submerged aerated biofilter used for post-treatment of the effluent of an UASB reactor, under unfavorable hydraulic conditions: full-scale study

Godoy, Thais Gorga de 14 September 2007 (has links)
Esta pesquisa avaliou a eficiência do biofiltro aerado submerso empregado no pós-tratamento do efluente do reator anaeróbio de manta de lodo (UASB), em escala real, localizado na ETE Água Vermelha em São Carlos, SP, sob condições hidráulicas desfavoráveis. Estudou-se a remoção de matéria orgânica e de sólidos, a possibilidade de remoção de nitrogênio e fósforo e também as características da biomassa aderida ao meio suporte. O estudo foi desenvolvido em duas fases, uma sem a adição de inóculo (fase I) e outra com inoculação (fase II). Na fase I foi aplicada vazão de 380 m³/dia, cargas orgânicas volumétricas (COV) de 3kgDQO/m³.dia com carga hidráulica (CH) de 8 m³/m².dia e tempo de detenção hidráulica (TDH) de 170 minutos. Nesta fase o biofiltro alcançou eficiências médias de 40% na remoção de matéria orgânica (DQO) e de 35% para os SST. Na segunda fase foram aplicadas vazões de 500 m³/dia, COV de 4 kg DQO/ m³.dia com CH de 11 m³/ m².dia e TDH de 130 minutos. O BAS apresentou eficiências médias de remoção de DQO, \'COT IND.F\' e SST de 36%, 60% e 30%, respectivamente, para a fase II. A conversão de nitrito a nitrato foi considerada desprezível, podendo ser atribuída ao alto valor de DQO afluente ao BAS, à ocorrência de nitrificação e desnitrificação no mesmo biofilme e à distribuição ineficiente de ar no interior do reator. O biofiltro não apresentou bons resultados quanto à remoção de fósforo durante a pesquisa. O estudo permitiu concluir que o BAS apresentou um desempenho satisfatório como unidade de pós-tratamento de reator UASB na fase de partida, mesmo sendo submetido a altas cargas hidráulicas e orgânicas. Constatou-se, portanto, que o emprego do biofiltro aerado submerso apresenta-se como uma alternativa vantajosa para o pós-tratamento do efluente de reatores anaeróbios, produzindo um efluente de excelente qualidade. / This research evaluated the efficiency of a full scale submerged aerated biofilter (SAB) used for post-treatment of the effluent of an upflow anaerobic sludge blanket (UASB) reactor, located in the wastewater treatment plant Água Vermelha (São Carlos, SP, Brazil), under unfavorable hydraulic conditions. The removal of organic matter and solids, the possibility of removal of nitrogen and phosphorus and also the characterization of biomass attached to the packing media were studied. This study vas developed in two phases, one without reactor seeding (phase I), and another when the reactor was seeded (phase II). At phase I, a flow rate of 380 m³/d and a volumetric loading rate of 3 kgCOD/m³.d with hydraulic load (HL) of 8 m³/m².d were applied, with 170 minutes of hydraulic retention time (HRT). In this phase the biofilter reached average efficiencies of 40% in organic matter removal (COD) and 35% for TSS. Already in phase II, a flow rate of 500 m³/d, a volumetric loading rate of 4kgCOD/m³.d with HL of 11 m³/ m².dia were applied, with 130 minutes of HRT. The SAB allowed average removal efficiencies of COD, \'TOC IND.F\' and TSS of 36%, 60% and 30%, respectively, for phase II. The conversion of nitrite to nitrate was considered worthless, likely attributed to the high value of affluent COD to the SAB, the occurrence of nitrification and denitrification in the same biofilm and the inefficient air distribution in the interior of the reactor. The biofilter did not present good results in phosphorus removal. This study allowed to conclude that the aerated submerged biological filter presented a satisfactory performance as a post-treatment unit of an UASB reactor during the start-up phase, being submitted to high hydraulic and organic loads. It was found that the employment of the submerged aerated biofilter is an advantageous alternative as anaerobic effluent post-treatment, producing excellent quality effluent.
49

Comportamento de reator UASB sem separador trifásico no tratamento de esgoto sanitário. / Behavior of UASB reactor without three-phase separator in the sewage treatment.

Camargo, Bruno Martins de 05 September 2016 (has links)
O objetivo do presente trabalho foi a avaliação das características operacionais de um reator UASB sem o dispositivo de coleta de gás (separador trifásico) e sem o anteparo retentor de escuma posicionado próximo à canaleta de coleta do efluente. A motivação para esta pesquisa foi o interesse manifestado pelas companhias de saneamento em aplicar esta simplificação, que poderá implicar em economia na implantação dos reatores e praticamente na eliminação da necessidade de remoção de escuma. Utilizou-se um reator UASB com tais simplificações com volume útil de 24,5 m3 e estabeleceu-se uma estratégia operacional com aumento gradual da vazão de alimentação, compondo quatro fases de operação, com tempos de retenção hidráulica respectivamente de 16, 12, 10 e 8 horas. As vazões foram mantidas constantes em cada fase, com exceção da última, em que se impôs dois picos de vazão ao longo dia. O reator manteve-se operando com eficiências médias de remoção de DQO total, respectivamente, de 65,9%, 60,3%, 48,7% e 15,0%. De modo geral, pode-se afirmar que o reator piloto não apresentou o desempenho esperado, em termos de remoção de matéria orgânica, para TDH de 8 horas. Quanto ao perfil de sólidos no manto de lodo, nas duas primeiras etapas (TDH de 16 e 12 horas), o teor de sólidos daquele foi elevado, mas reduziu-se drasticamente a partir da etapa com TDH de 10 horas. Na última etapa, o comportamento da manta de lodo foi pouco previsível, observando-se progressivo arraste de sólidos do reator. Em função da grande perda de sólidos, acredita-se que o artifício empregado possa ser utilizado com melhor desempenho com a implantação de um decantador a jusante do reator ou mediante a aplicação de um pós-tratamento que garanta a recuperação dos sólidos perdidos (por exemplo, lodos ativados). Outra alternativa é a própria substituição do UASB pelo decantador primário antes de um pós-tratamento aeróbio. / The objective of this study was to evaluate the operational characteristics of a UASB reactor without the gas collection device (three phase separator) and without the scum retainer screen positioned near the effluent collection channel. The motivation for this research was the interest shown by sanitation companies to apply this simplification, which can result in savings in the implementation of the reactors and practically in eliminating the need of scum removal. An UASB reactor was used with such simplifications with a volume of 24.5 m3 and an operational strategy was established with gradual increase of the feed flow, consisting of four operating phases, with hydraulic retention times, respectively, of 16, 12, 10 and 8 hours. The flows were kept constants at each operating phase, except the last, which was imposed two peak flows throughout the day. The reactor was kept operating with efficiency of COD removal, respectively, of 65.9%, 60.3%, 48.7% and 15,0%. Generally, the pilot reactor had not the expected performance in removal of organic matter, with hydraulic retention time of 8 hours. In the first two fases (HDT of 16 and 12 hours), solid\'s content in sludge blanket was high, but had reduced significantly from the second fase, with 10 hours of HDT. In the last fase, the sludge blanket behavior was bit predictable, with progressive drag of solids from reactor. Because of high solids loss, it is believed that the applied device can be used with better performance with the implantation of a settler after the reactor or a post-treatment that ensures the lost solids recovery (for example, activated sludge). Another alternative is the replacement of UASB by the primary clarifier before aerobic post-treatment.
50

Aplicação de lise celular forçada em sistema de tratamento aeróbio precedido de reator UASB

Parsekian, Marilú Pereira Serafim 09 May 2003 (has links)
Este estudo visou avaliar as implicações do uso da lise celular sobre a produção de lodos e acumulação de nutrientes no efluente do sistema combinado de tratamento (anaeróbio/aeróbio) de despejo sintético simulando esgoto sanitário. O sistema operado era constituído de reator UASB (V = 10,5 l), reator aeróbio (V = 4,4 l) e sedimentador (V = 2,7 l), operando com tempo de detenção hidráulica de 8,0 h, 3,5 h e 2,7 h respectivamente. Durante a fase de controle, acompanhou-se as características de funcionamento do processo sem o emprego da lise celular no lodo de excesso e posteriormente fez-se uso de equipamento de ultra-som para promover a lise do lodo, com retorno posterior do lodo lisado à entrada do reator UASB. Verificou-se que a eficiência média global de remoção de DQO do sistema foi de 90% em ambas as fases considerando DQO efluente filtrada. A conversão de nitrogênio amoniacal a nitrato foi pequena no tanque de aeração e a remoção de fósforo foi insignificante no processo de tratamento, no entanto não ocorreu alteração na qualidade do efluente do sistema em função do retorno do material lisado. Na escala estudada foi freqüente o aparecimento de bulking (controlado pela aplicação de hipoclorito de sódio no sedimentador), fato esse que dificultou a operação do sistema de tratamento e interferiu na manutenção do tempo de retenção celular. Os resultados obtidos da simulação realizada por meio do software GPS-X 4.0, para reator em escala real empregando a lise celular, mostraram acréscimo na concentração de fósforo total no efluente de 30% após 5 anos de operação / The aim of this research is to value the use of cell lyses over the sludge production and effluent nutrient accumulation from a combined treatment system (anaerobic/aerobic) from a synthetic sanitary wastewater. The parts of this system where one UASB reactor (V = 10,5 l), one aeration tank (V = 4,4 l) and one sedimentation tank (V = 2,7 l), hydraulic detention times of 8,0 h, 3,5 h e 2,7 h, respectively. During the control period, the characteristics of the system working without the use of cell lyses were recorded. After this phase, ultrasound equipment was used to cause the sludge lyses and then the sludge was returned to the entrance of the UASB reactor. From these tests we could not observe changes in mean global DQO removal efficiency for the both phases and it was 90% considering filtrated effluent COD. Few ammonia-nitrogen changes into nitrate inside the aeration tank were observed. Phosphorus removal in the treatment system was insignificant, but we could notice no damage to the treatment system caused by the lyses material returned. In the reduced scale of the system bulking events were frequent. This was controlled with sodium hypochlorite at the sedimentation tank, but these events caused operation difficulties and had interfered on the cellular detention time maintenance. Results from a real scale simulation, using cell lyses, done with the GPS-X 4.0 software, show an increase in effluent total phosphorus equal to 30% after 5 years

Page generated in 0.4256 seconds